1725956610000 | 0 | None | None | Other Works | Construction of toilets for disabled in government school/office buildings | 109216.81 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3949699 | 152959 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD SR 23-24 Vol-1 P-5 I-1.4.1) | Cum | 249.26 | 249.26 | 3.6 | False | None | None | False | None | False | 897.336 | 0 | 3949700 | 152959 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 23-24 Vol-1 P-15 I-2.1.3) | Cum | 6168.67 | 6168.67 | 1.2 | False | None | None | False | None | False | 7402.404 | 0 | 3949701 | 152959 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR 23-24 Vol-1 P-9 I-5.1.1) | Cum | 5779.33 | 5779.33 | 3.99 | False | None | None | False | None | False | 23059.5267 | 0 | 3949702 | 152959 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR 23-24 Vol-1 P-7 I-1.9) | Cum | 273.98 | 273.98 | 3.52 | False | None | None | False | None | False | 964.4096 | 0 | 3949703 | 152959 | None | code05 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR 23-24 Vol-2 P-13 I-6.5) | Cum | 11306.31 | 11306.31 | 2.1 | False | None | None | False | None | False | 23743.251 | 0 | 3949704 | 152959 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m 6630.0 (PWD SR 23-24 Vol-1 P-16 I-2.5.1) | Cum | 8194.8 | 8194.8 | 0.4 | False | None | None | False | None | False | 3277.92 | 0 | 3949705 | 152959 | None | code07 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings (PWD SR 23-24 Vol-1 P-18 I-2.11 a) | Tonne | 92140.71 | 92140.71 | 0.036 | False | None | None | False | None | False | 3317.06556 | 0 | 3949706 | 152959 | None | code08 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 23-24 Vol-2 P-41 I-8.1.2) | Sqm | 248.23 | 248.23 | 28.52 | False | None | None | False | None | False | 7079.5196 | 0 | 3949707 | 152959 | None | code09 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (PWD SR 23-24 Vol-2 P-131 I-14.2.1) | Each | 4983.14 | 4983.14 | 1.0 | False | None | None | False | None | False | 4983.14 | 0 | 3949708 | 152959 | None | code10 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (PWD CSR 2023-24, Vol-II, P. 123, I.13.34) | Ltr | 9.27 | 9.27 | 500.0 | False | None | None | False | None | False | 4635.0 | 0 | 3949709 | 152959 | None | code11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.33.4 | Mtr | 383.16 | 383.16 | 18.0 | False | None | None | False | None | False | 6896.88 | 0 | 3949710 | 152959 | None | code12 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge 42x50 mm PVC Extruded section PWD CSR 2023-24, Vol-II, P. No. 108, I. No. 12.83.2 | Sqm | 246.17 | 246.17 | 6.0 | False | None | None | False | None | False | 1477.02 | 0 | 3949711 | 152959 | None | code13 | Providing& fixing of Openable door made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge andMulti point locking system with Handle. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made) PWD CSR 2023-24, Vol-II, P. No. 111, I. No. 12.92 | Mtr | 6432.35 | 6432.35 | 1.89 | False | None | None | False | None | False | 12157.1415 | 0 | 3949712 | 152959 | None | code14 | Earth work excavation for pipeline trenches in all kinds of soils by mechanicalmeans as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading, caution lights, bracing, usingsight rails & bonding rods at every 100 mm wherever necessary as directed,removal of stumps and other deleterious matter, dressing of sides and levellingthe bottom of trench to the extent required , utilising the available excavatedearth locally for the work etc., and all other appurtenances complete in thefollowing strata. (p.no.10.i.no.1.17.1) COMMON SCHEDULE OF RATES 2023-24 TECHNICAL WORKING GROUP VOLUME-I | Cum | 269.86 | 269.86 | 2.7 | False | None | None | False | None | False | 728.622 | 0 | 3949713 | 152959 | None | code15 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from theexcavationetc. complete. 6 Kg/m2: 200mm(weight of pipe -6.233 kg) (p.no.120. it.no 10.14.14) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES VOLUME-V | Mtr | 996.01 | 996.01 | 5.0 | False | None | None | False | None | False | 4980.05 | 0 | 3949714 | 152959 | None | code16 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming afterwatering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications (p.no.7.i.no.1.10) COMMON SCHEDULE OF RATES 2023-24 TECHNICAL WORKING GROUP VOLUME-I | Cum | 164.8 | 164.8 | 2.7 | False | None | None | False | None | False | 444.96 | 0 | 3949715 | 152959 | None | code17 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. 108.00 (PWD CSR 2023-24, Vol-II, P. No.45, I. No.8.24) | Mtr | 111.24 | 111.24 | 28.52 | False | None | None | False | None | False | 3172.5648 | 0 |
|