3950374 | 152986 | None | code01 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1354.1 | 1354.1 | 51.24 | False | None | None | False | None | False | 69384.084 | 0 |
3950375 | 152986 | None | code02 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1214.4 | 1214.4 | 569.12 | False | None | None | False | None | False | 691139.328 | 0 |
3950376 | 152986 | None | code03 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 324.5 | 324.5 | 1316.82 | False | None | None | False | None | False | 427308.09 | 0 |
3950377 | 152986 | None | code04 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 3137.2 | 3137.2 | 400.0 | False | None | None | False | None | False | 1254880.0 | 0 |
3950378 | 152986 | None | code05 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. | Sqm | 4330.7 | 4330.7 | 87.775 | False | None | None | False | None | False | 380127.1925 | 0 |
3950379 | 152986 | None | code06 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1292.5 | 1292.5 | 728.66 | False | None | None | False | None | False | 941793.05 | 0 |
3950380 | 152986 | None | code07 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1214.4 | 1214.4 | 144.06 | False | None | None | False | None | False | 174946.464 | 0 |
3950381 | 152986 | None | code08 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x1200mm | Sqm | 1478.4 | 1478.4 | 489.6 | False | None | None | False | None | False | 723824.64 | 0 |
3950382 | 152986 | None | code09 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 977.9 | 977.9 | 53.28 | False | None | None | False | None | False | 52102.512 | 0 |
3950383 | 152986 | None | code10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 110.0 | 110.0 | 801.26 | False | None | None | False | None | False | 88138.6 | 0 |
3950384 | 152986 | None | code11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.7 | 183.7 | 801.26 | False | None | None | False | None | False | 147191.462 | 0 |
3950385 | 152986 | None | code12 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 9103.6 | 9103.6 | 31.89 | False | None | None | False | None | False | 290313.804 | 0 |
3950386 | 152986 | None | code13 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 161.7 | 161.7 | 14584.5 | False | None | None | False | None | False | 2358313.65 | 0 |
3950387 | 152986 | None | code14 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 632.5 | 632.5 | 333.55 | False | None | None | False | None | False | 210970.375 | 0 |
3950388 | 152986 | None | code15 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 521.4 | 521.4 | 500.325 | False | None | None | False | None | False | 260869.455 | 0 |
3950389 | 152986 | None | code16 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Cum | 328.9 | 328.9 | 237.5 | False | None | None | False | None | False | 78113.75 | 0 |
3950390 | 152986 | None | code17 | Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, remova of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth ocally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m | Cum | 499.4 | 499.4 | 45.0 | False | None | None | False | None | False | 22473.0 | 0 |
3950391 | 152986 | None | code18 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6587.9 | 6587.9 | 294.67 | False | None | None | False | None | False | 1941256.493 | 0 |
3950392 | 152986 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7293.0 | 7293.0 | 262.6125 | False | None | None | False | None | False | 1915232.9625 | 0 |
3950393 | 152986 | None | code20 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6838.7 | 6838.7 | 7.74 | False | None | None | False | None | False | 52931.538 | 0 |
3950394 | 152986 | None | code21 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 898.7 | 898.7 | 1367.5075 | False | None | None | False | None | False | 1228978.99025 | 0 |
3950395 | 152986 | None | code22 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand,
filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge | Sqm | 880.0 | 880.0 | 1667.75 | False | None | None | False | None | False | 1467620.0 | 0 |
3950396 | 152986 | None | code23 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6955.3 | 6955.3 | 78.43 | False | None | None | False | None | False | 545504.179 | 0 |
3950397 | 152986 | None | code24 | Providing and fixing Reinforced Concrete covering Slab of 10cm Thick made of M20 with OPC Cement with 20mm and down size graded granite metal coarse 0.70mixed including providing and removing centering shuttering etc edges of slab with TMT FE500 including labour, all lead and lift HOM of m,achinery curing cost of reinforcement complete as per direction of Engineer in Charge | Sqm | 2072.0 | 2072.0 | 117.75 | False | None | None | False | None | False | 243978.0 | 0 |
3950398 | 152986 | None | code25 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | MT | 98402.7 | 98402.7 | 8.83 | False | None | None | False | None | False | 868895.841 | 0 |
3950399 | 152986 | None | code26 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7279.8 | 7279.8 | 134.94 | False | None | None | False | None | False | 982336.212 | 0 |
3950400 | 152986 | None | code27 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge. m2 354.00 | Sqm | 389.4 | 389.4 | 117.75 | False | None | None | False | None | False | 45851.85 | 0 |
3950401 | 152986 | None | code28 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11290.95 | 11290.95 | 12.132 | False | None | None | False | None | False | 136981.8054 | 0 |
3950402 | 152986 | None | code29 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12043.68 | 12043.68 | 3.08 | False | None | None | False | None | False | 37094.5344 | 0 |
3950403 | 152986 | None | code30 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : | Sqm | 1260.6 | 1260.6 | 134.16 | False | None | None | False | None | False | 169122.096 | 0 |
3950404 | 152986 | None | code31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and | Kg | 640.2 | 640.2 | 624.24 | False | None | None | False | None | False | 399638.448 | 0 |
3950405 | 152986 | None | code32 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 621.5 | 621.5 | 733.95 | False | None | None | False | None | False | 456149.925 | 0 |
3950406 | 152986 | None | code33 | Fabricating providing and erectingin position of MS Hot dip galvanized Sq Hollow poles of 132x132heavy gauge of height 3000mmwith MS hot dip galvanised Grills work as per approved designand drawing of chief architectUsing 12 75mm flatfor alround frame and 20x20mm galvanised forged ornamental arrowhead at top & bottom. The work is inclusive of throughing flat square rods placing welding joints including grinding finishing 2 coats ofantocorrosive paint over one coat of metal primer. the rate is inclusive of alll matrials like MS Hollow galvanised pipe, flat, forged square rods cost of labour for all items of work cost painting welding cutting grinding with alll lead and lift as per specification including loading with cost and conveyance of all materials labour, machinery and inciddental charges for the succesfull complete of work as per direction of engineer in charge of work | Sqm | 15630.0 | 15630.0 | 163.5 | False | None | None | False | None | False | 2555505.0 | 0 |
3950407 | 152986 | None | code34 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 151881.4 | 151881.4 | 0.84 | False | None | None | False | None | False | 127580.376 | 0 |
3950408 | 152986 | None | code35 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak | Sqm | 4447.3 | 4447.3 | 23.04 | False | None | None | False | None | False | 102465.792 | 0 |
3950409 | 152986 | None | code36 | Providing and fixing 5 Seater SS Chairs as per direction of Engineer in charge | No | 11195.0 | 11195.0 | 5.0 | False | None | None | False | None | False | 55975.0 | 0 |
3950410 | 152986 | None | code37 | Providing and fixing Doctors table as per direction of engineer in charge | No | 16784.0 | 16784.0 | 8.0 | False | None | None | False | None | False | 134272.0 | 0 |
3950411 | 152986 | None | code38 | Providing and fixing Doctors Chairs as per direction of engineer in charge | No | 7833.0 | 7833.0 | 8.0 | False | None | None | False | None | False | 62664.0 | 0 |
3950412 | 152986 | None | code39 | Providing and fixing Name Boards as per direction of Engineer in charge | No | 13427.0 | 13427.0 | 2.0 | False | None | None | False | None | False | 26854.0 | 0 |
3950413 | 152986 | None | code40 | Providing and fixing Nursing station(in corner+ table as per direction of Engineer in charge | No | 33569.0 | 33569.0 | 2.0 | False | None | None | False | None | False | 67138.0 | 0 |
3950414 | 152986 | None | code41 | Providing and fixing Patient Chair as per direction of Engineer in charge | No | 3357.0 | 3357.0 | 8.0 | False | None | None | False | None | False | 26856.0 | 0 |
3950415 | 152986 | None | code42 | Providing and fixing RO Filter as per direction of Engineer in charge | No | 27974.0 | 27974.0 | 3.0 | False | None | None | False | None | False | 83922.0 | 0 |
3950416 | 152986 | None | code43 | Providing and supplying Emergency recovery trolly as per direction of Engineer in charge | No | 72732.0 | 72732.0 | 2.0 | False | None | None | False | None | False | 145464.0 | 0 |
3950417 | 152986 | None | code44 | Providing and supplying examination table with bed as per direction of Engineer in charge | No | 27974.0 | 27974.0 | 8.0 | False | None | None | False | None | False | 223792.0 | 0 |
3950418 | 152986 | None | code45 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,20 Passengers PWD ELE SR 23-24,PG NO-58, 14. | No | 3171861.0 | 3171861.0 | 1.0 | False | None | None | False | None | False | 3171861.0 | 0 |
3950419 | 152986 | None | code46 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,20 Passengers PWD ELE SR 23-24,PG NO-58, 14. | No | 1604341.2 | 1604341.2 | 1.0 | False | None | None | False | None | False | 1604341.2 | 0 |
3950420 | 152986 | None | code47 | Open Conduit System.Supply Heavy gauge PVC conduit pipe --- dia -- mm thich confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC eall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws. 19/20mm dia 2mm thick | m | 75.9 | 75.9 | 250.0 | False | None | None | False | None | False | 18975.0 | 0 |
3950421 | 152986 | None | code48 | 25 mm dia 2mm thick | m | 89.1 | 89.1 | 300.0 | False | None | None | False | None | False | 26730.0 | 0 |
3950422 | 152986 | None | code49 | 32mm dia 2.5mm thick | m | 116.6 | 116.6 | 200.0 | False | None | None | False | None | False | 23320.0 | 0 |
3950423 | 152986 | None | code50 | 40mm dia 2.5mm thick | m | 163.9 | 163.9 | 100.0 | False | None | None | False | None | False | 16390.0 | 0 |
3950424 | 152986 | None | code51 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 19/20mm dia 2mm thick | m | 74.8 | 74.8 | 650.0 | False | None | None | False | None | False | 48620.0 | 0 |
3950425 | 152986 | None | code52 | 25 mm dia 2mm thick | m | 86.9 | 86.9 | 1750.0 | False | None | None | False | None | False | 152075.0 | 0 |
3950426 | 152986 | None | code53 | 32mm dia 2.5mm thick | m | 108.9 | 108.9 | 100.0 | False | None | None | False | None | False | 10890.0 | 0 |
3950427 | 152986 | None | code54 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/lconduit entry as required with one coat of primer of approved make etc. 200x200x65 mm | Each | 382.8 | 382.8 | 20.0 | False | None | None | False | None | False | 7656.0 | 0 |
3950428 | 152986 | None | code55 | Supplying and fixing PVC/Metal conduit Deep Junction box 19/20mm deep Junction box | Each | 53.9 | 53.9 | 120.0 | False | None | None | False | None | False | 6468.0 | 0 |
3950429 | 152986 | None | code56 | 25mm deep Junction box | Each | 61.6 | 61.6 | 500.0 | False | None | None | False | None | False | 30800.0 | 0 |
3950430 | 152986 | None | code57 | 32mm deep Junction box | Each | 67.1 | 67.1 | 40.0 | False | None | None | False | None | False | 2684.0 | 0 |
3950431 | 152986 | None | code58 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | m | 31.9 | 31.9 | 500.0 | False | None | None | False | None | False | 15950.0 | 0 |
3950432 | 152986 | None | code59 | upto 50 mm conduit CC floor | m | 75.9 | 75.9 | 20.0 | False | None | None | False | None | False | 1518.0 | 0 |
3950433 | 152986 | None | code60 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required. 25mm | m | 38.5 | 38.5 | 500.0 | False | None | None | False | None | False | 19250.0 | 0 |
3950434 | 152986 | None | code61 | 32mm | m | 47.3 | 47.3 | 250.0 | False | None | None | False | None | False | 11825.0 | 0 |
3950435 | 152986 | None | code62 | 38mm | m | 68.2 | 68.2 | 100.0 | False | None | None | False | None | False | 6820.0 | 0 |
3950436 | 152986 | None | code63 | 50mm | m | 47.3 | 47.3 | 100.0 | False | None | None | False | None | False | 4730.0 | 0 |
3950437 | 152986 | None | code64 | Supplying PVC/GI Flexible conduit pipe -- mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y. 25mm | m | 24.2 | 24.2 | 850.0 | False | None | None | False | None | False | 20570.0 | 0 |
3950438 | 152986 | None | code65 | 32mm | m | 31.9 | 31.9 | 200.0 | False | None | None | False | None | False | 6380.0 | 0 |
3950439 | 152986 | None | code66 | 38mm | m | 39.6 | 39.6 | 100.0 | False | None | None | False | None | False | 3960.0 | 0 |
3950440 | 152986 | None | code67 | 50mm | m | 51.7 | 51.7 | 50.0 | False | None | None | False | None | False | 2585.0 | 0 |
3950441 | 152986 | None | code68 | Supplying and fixing S hook made out of 14mm dia MS Rod | No | 57.2 | 57.2 | 10.0 | False | None | None | False | None | False | 572.0 | 0 |
3950442 | 152986 | None | code69 | Supplying and fixing MS rafter clamp set made out of MS flat & 14mm MS Rod. | No | 176.0 | 176.0 | 10.0 | False | None | None | False | None | False | 1760.0 | 0 |
3950443 | 152986 | None | code70 | Supplying and fixing of Metal Fan box with Round Hook. | No | 128.7 | 128.7 | 65.0 | False | None | None | False | None | False | 8365.5 | 0 |
3950444 | 152986 | None | code71 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 295.9 | 295.9 | 36.0 | False | None | None | False | None | False | 10652.4 | 0 |
3950445 | 152986 | None | code72 | Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 416.9 | 416.9 | 90.0 | False | None | None | False | None | False | 37521.0 | 0 |
3950446 | 152986 | None | code73 | Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 610.5 | 610.5 | 80.0 | False | None | None | False | None | False | 48840.0 | 0 |
3950447 | 152986 | None | code74 | Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 744.7 | 744.7 | 80.0 | False | None | None | False | None | False | 59576.0 | 0 |
3950448 | 152986 | None | code75 | Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches | Point | 1087.9 | 1087.9 | 30.0 | False | None | None | False | None | False | 32637.0 | 0 |
3950449 | 152986 | None | code76 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments. 1 Sq.mm | m | 20.9 | 20.9 | 4000.0 | False | None | None | False | None | False | 83600.0 | 0 |
3950450 | 152986 | None | code77 | 1.5 Sq.mm | m | 28.6 | 28.6 | 12000.0 | False | None | None | False | None | False | 343200.0 | 0 |
3950451 | 152986 | None | code78 | 2.5 Sq.mm | m | 46.2 | 46.2 | 13000.0 | False | None | None | False | None | False | 600600.0 | 0 |
3950452 | 152986 | None | code79 | 4 Sq.mm | m | 69.3 | 69.3 | 9000.0 | False | None | None | False | None | False | 623700.0 | 0 |
3950453 | 152986 | None | code80 | 6 Sq.mm | m | 101.2 | 101.2 | 600.0 | False | None | None | False | None | False | 60720.0 | 0 |
3950454 | 152986 | None | code81 | 10 Sq.mm | m | 183.7 | 183.7 | 200.0 | False | None | None | False | None | False | 36740.0 | 0 |
3950455 | 152986 | None | code82 | 16 Sq.mm | m | 349.8 | 349.8 | 300.0 | False | None | None | False | None | False | 104940.0 | 0 |
3950456 | 152986 | None | code83 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 136.4 | 136.4 | 10.0 | False | None | None | False | None | False | 1364.0 | 0 |
3950457 | 152986 | None | code84 | 4-5Way | Each | 150.7 | 150.7 | 10.0 | False | None | None | False | None | False | 1507.0 | 0 |
3950458 | 152986 | None | code85 | 6Way | Each | 190.3 | 190.3 | 10.0 | False | None | None | False | None | False | 1903.0 | 0 |
3950459 | 152986 | None | code86 | 8 Way | Each | 240.9 | 240.9 | 5.0 | False | None | None | False | None | False | 1204.5 | 0 |
3950460 | 152986 | None | code87 | 10-12Way | Each | 287.1 | 287.1 | 5.0 | False | None | None | False | None | False | 1435.5 | 0 |
3950461 | 152986 | None | code88 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 174.9 | 174.9 | 40.0 | False | None | None | False | None | False | 6996.0 | 0 |
3950462 | 152986 | None | code89 | 4-5Way | Each | 194.7 | 194.7 | 15.0 | False | None | None | False | None | False | 2920.5 | 0 |
3950463 | 152986 | None | code90 | 6 Way | Each | 242.0 | 242.0 | 20.0 | False | None | None | False | None | False | 4840.0 | 0 |
3950464 | 152986 | None | code91 | 8 Way | Each | 287.1 | 287.1 | 40.0 | False | None | None | False | None | False | 11484.0 | 0 |
3950465 | 152986 | None | code92 | 10-12Way | Each | 350.9 | 350.9 | 50.0 | False | None | None | False | None | False | 17545.0 | 0 |
3950466 | 152986 | None | code93 | 16 Way | Each | 399.3 | 399.3 | 18.0 | False | None | None | False | None | False | 7187.4 | 0 |
3950467 | 152986 | None | code94 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 177.1 | 177.1 | 50.0 | False | None | None | False | None | False | 8855.0 | 0 |
3950468 | 152986 | None | code95 | 4 Module | Each | 192.5 | 192.5 | 25.0 | False | None | None | False | None | False | 4812.5 | 0 |
3950469 | 152986 | None | code96 | 6 Module | Each | 257.4 | 257.4 | 30.0 | False | None | None | False | None | False | 7722.0 | 0 |
3950470 | 152986 | None | code97 | 8 Module | Each | 312.4 | 312.4 | 45.0 | False | None | None | False | None | False | 14058.0 | 0 |
3950471 | 152986 | None | code98 | 10-12 Module | Each | 378.4 | 378.4 | 55.0 | False | None | None | False | None | False | 20812.0 | 0 |
3950472 | 152986 | None | code99 | 16 Module | Each | 436.7 | 436.7 | 18.0 | False | None | None | False | None | False | 7860.6 | 0 |
3950473 | 152986 | None | code100 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 112.2 | 112.2 | 1000.0 | False | None | None | False | None | False | 112200.0 | 0 |
3950474 | 152986 | None | code101 | 6Amps Two way Switch | Each | 182.6 | 182.6 | 30.0 | False | None | None | False | None | False | 5478.0 | 0 |
3950475 | 152986 | None | code102 | 6Amps 3way socket | Each | 188.1 | 188.1 | 500.0 | False | None | None | False | None | False | 94050.0 | 0 |
3950476 | 152986 | None | code103 | Stepped Fan Regulator Two Module. | Each | 392.7 | 392.7 | 50.0 | False | None | None | False | None | False | 19635.0 | 0 |
3950477 | 152986 | None | code104 | 16Amps one way switch | Each | 198.0 | 198.0 | 200.0 | False | None | None | False | None | False | 39600.0 | 0 |
3950478 | 152986 | None | code105 | 6A Bell Push | Each | 194.7 | 194.7 | 20.0 | False | None | None | False | None | False | 3894.0 | 0 |
3950479 | 152986 | None | code106 | 32Amps DP switch | Each | 358.6 | 358.6 | 20.0 | False | None | None | False | None | False | 7172.0 | 0 |
3950480 | 152986 | None | code107 | 6/16Amps universal socket | Each | 259.6 | 259.6 | 150.0 | False | None | None | False | None | False | 38940.0 | 0 |
3950481 | 152986 | None | code108 | Television | Each | 171.6 | 171.6 | 5.0 | False | None | None | False | None | False | 858.0 | 0 |
3950482 | 152986 | None | code109 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 710.6 | 710.6 | 5.0 | False | None | None | False | None | False | 3553.0 | 0 |
3950483 | 152986 | None | code110 | Supplying 50mm wooden plug, tapered from 50x50mm to 25x25mm and fixing by using binding wire before concreting a roof slab. | Each | 13.2 | 13.2 | 1650.0 | False | None | None | False | None | False | 21780.0 | 0 |
3950484 | 152986 | None | code111 | Supplying ......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 6 to 10 Way Gang Box | Each | 58.3 | 58.3 | 5.0 | False | None | None | False | None | False | 291.5 | 0 |
3950485 | 152986 | None | code112 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose. | No | 85.8 | 85.8 | 70.0 | False | None | None | False | None | False | 6006.0 | 0 |
3950486 | 152986 | None | code113 | 6A Pendant Holder | No | 78.1 | 78.1 | 70.0 | False | None | None | False | None | False | 5467.0 | 0 |
3950487 | 152986 | None | code114 | 6A Batten Holder | No | 81.4 | 81.4 | 250.0 | False | None | None | False | None | False | 20350.0 | 0 |
3950488 | 152986 | None | code115 | Supplying and fixing of minature circuit breakers on exisitng MCB distrubution boards using necessary fixing materials and C Type curve, indicator ON/OFF energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32A SP | Each | 456.5 | 456.5 | 250.0 | False | None | None | False | None | False | 114125.0 | 0 |
3950489 | 152986 | None | code116 | 6-32A DP | Each | 812.9 | 812.9 | 20.0 | False | None | None | False | None | False | 16258.0 | 0 |
3950490 | 152986 | None | code117 | 6-32A TPN | Each | 1888.7 | 1888.7 | 10.0 | False | None | None | False | None | False | 18887.0 | 0 |
3950491 | 152986 | None | code118 | 40A TPN | Each | 3348.4 | 3348.4 | 10.0 | False | None | None | False | None | False | 33484.0 | 0 |
3950492 | 152986 | None | code119 | 50-63A TPN | Each | 3396.8 | 3396.8 | 30.0 | False | None | None | False | None | False | 101904.0 | 0 |
3950493 | 152986 | None | code120 | Supplying and fixing regular MCB distrubution boards on wall/wood board/ flush mounting ….....with poweder coated painting made out of 14SWG MS enclosure. 16 way SP&N | Each | 3198.8 | 3198.8 | 6.0 | False | None | None | False | None | False | 19192.8 | 0 |
3950494 | 152986 | None | code121 | 6 Way TP & N | Each | 5434.0 | 5434.0 | 6.0 | False | None | None | False | None | False | 32604.0 | 0 |
3950495 | 152986 | None | code122 | 8 Way TP & N | Each | 6700.1 | 6700.1 | 6.0 | False | None | None | False | None | False | 40200.6 | 0 |
3950496 | 152986 | None | code123 | 12 Way TP & N | Each | 6700.1 | 6700.1 | 6.0 | False | None | None | False | None | False | 40200.6 | 0 |
3950497 | 152986 | None | code124 | Supplying,fixing and wiring residual current circuit breaker (RCCB) 240v/450v upto 300mA sensitivity on exisitng wood panel board. 16A-25A 2 pole | Each | 4704.7 | 4704.7 | 40.0 | False | None | None | False | None | False | 188188.0 | 0 |
3950498 | 152986 | None | code125 | 32-40A 4 pole | Each | 5661.7 | 5661.7 | 8.0 | False | None | None | False | None | False | 45293.6 | 0 |
3950499 | 152986 | None | code126 | 63 A 4 Pole | Each | 6099.5 | 6099.5 | 8.0 | False | None | None | False | None | False | 48796.0 | 0 |
3950500 | 152986 | None | code127 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 129804.4 | 129804.4 | 0.3 | False | None | None | False | None | False | 38941.32 | 0 |
3950501 | 152986 | None | code128 | 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 156026.2 | 156026.2 | 0.9 | False | None | None | False | None | False | 140423.58 | 0 |
3950502 | 152986 | None | code129 | 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 153503.9 | 153503.9 | 0.35 | False | None | None | False | None | False | 53726.365 | 0 |
3950503 | 152986 | None | code130 | 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 196870.3 | 196870.3 | 0.1 | False | None | None | False | None | False | 19687.03 | 0 |
3950504 | 152986 | None | code131 | 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 410536.5 | 410536.5 | 0.1 | False | None | None | False | None | False | 41053.65 | 0 |
3950505 | 152986 | None | code132 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm | Km | 22974.6 | 22974.6 | 1.2 | False | None | None | False | None | False | 27569.52 | 0 |
3950506 | 152986 | None | code133 | 35 sqmm to 95 sqmm | Km | 34252.9 | 34252.9 | 0.2 | False | None | None | False | None | False | 6850.58 | 0 |
3950507 | 152986 | None | code134 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia | Each | 86.9 | 86.9 | 20.0 | False | None | None | False | None | False | 1738.0 | 0 |
3950508 | 152986 | None | code135 | 32mm dia | Each | 104.5 | 104.5 | 20.0 | False | None | None | False | None | False | 2090.0 | 0 |
3950509 | 152986 | None | code136 | 40 mm dia | Each | 162.8 | 162.8 | 42.0 | False | None | None | False | None | False | 6837.6 | 0 |
3950510 | 152986 | None | code137 | 45mm dia | Each | 216.7 | 216.7 | 10.0 | False | None | None | False | None | False | 2167.0 | 0 |
3950511 | 152986 | None | code138 | 50mm dia | Each | 290.4 | 290.4 | 10.0 | False | None | None | False | None | False | 2904.0 | 0 |
3950512 | 152986 | None | code139 | 63mm dia | Each | 440.0 | 440.0 | 4.0 | False | None | None | False | None | False | 1760.0 | 0 |
3950513 | 152986 | None | code140 | 75mm dia | Each | 564.3 | 564.3 | 4.0 | False | None | None | False | None | False | 2257.2 | 0 |
3950514 | 152986 | None | code141 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 8.8 | 8.8 | 80.0 | False | None | None | False | None | False | 704.0 | 0 |
3950515 | 152986 | None | code142 | 16 sqmm | Each | 13.68 | 13.68 | 300.0 | False | None | None | False | None | False | 4104.0 | 0 |
3950516 | 152986 | None | code143 | 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm | Each | 29.7 | 29.7 | 40.0 | False | None | None | False | None | False | 1188.0 | 0 |
3950517 | 152986 | None | code144 | 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | Each | 44.0 | 44.0 | 16.0 | False | None | None | False | None | False | 704.0 | 0 |
3950518 | 152986 | None | code145 | 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm | Each | 63.8 | 63.8 | 16.0 | False | None | None | False | None | False | 1020.8 | 0 |
3950519 | 152986 | None | code146 | 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | Each | 141.9 | 141.9 | 8.0 | False | None | None | False | None | False | 1135.2 | 0 |
3950520 | 152986 | None | code147 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 150x50mm | Mtr | 509.3 | 509.3 | 75.0 | False | None | None | False | None | False | 38197.5 | 0 |
3950521 | 152986 | None | code148 | 300x50mm | Mtr | 645.7 | 645.7 | 75.0 | False | None | None | False | None | False | 48427.5 | 0 |
3950522 | 152986 | None | code149 | 600x50mm | Mtr | 1031.8 | 1031.8 | 20.0 | False | None | None | False | None | False | 20636.0 | 0 |
3950523 | 152986 | None | code150 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4681.6 | 4681.6 | 20.0 | False | None | None | False | None | False | 93632.0 | 0 |
3950524 | 152986 | None | code151 | 8 SWG-Cu Wire | Mtr | 115.5 | 115.5 | 350.0 | False | None | None | False | None | False | 40425.0 | 0 |
3950525 | 152986 | None | code152 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip | Mtr | 90.2 | 90.2 | 60.0 | False | None | None | False | None | False | 5412.0 | 0 |
3950526 | 152986 | None | code153 | 25x6mm GI strip | Mtr | 140.8 | 140.8 | 30.0 | False | None | None | False | None | False | 4224.0 | 0 |
3950527 | 152986 | None | code154 | 40x6mm GI strip | Mtr | 199.1 | 199.1 | 30.0 | False | None | None | False | None | False | 5973.0 | 0 |
3950528 | 152986 | None | code155 | 25x3mm Copper strip | Mtr | 627.0 | 627.0 | 80.0 | False | None | None | False | None | False | 50160.0 | 0 |
3950529 | 152986 | None | code156 | 25x6mm Copper strip | Mtr | 1210.0 | 1210.0 | 30.0 | False | None | None | False | None | False | 36300.0 | 0 |
3950530 | 152986 | None | code157 | 40x6mm Copper strip | Mtr | 1807.3 | 1807.3 | 30.0 | False | None | None | False | None | False | 54219.0 | 0 |
3950531 | 152986 | None | code158 | 600x600x3mm Copper plate | Each | 8163.1 | 8163.1 | 10.0 | False | None | None | False | None | False | 81631.0 | 0 |
3950532 | 152986 | None | code159 | Supplying & fixing - flexible LED Strip Light ..... W Power consumption in 5 ms length CCT6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition | m | 1420.1 | 1420.1 | 70.0 | False | None | None | False | None | False | 99407.0 | 0 |
3950533 | 152986 | None | code160 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 606.1 | 606.1 | 30.0 | False | None | None | False | None | False | 18183.0 | 0 |
3950534 | 152986 | None | code161 | LED light fighting 1 x4'- 20/22 w | Each | 759.0 | 759.0 | 100.0 | False | None | None | False | None | False | 75900.0 | 0 |
3950535 | 152986 | None | code162 | LED light fitting 1 x 4' - 36/40 W | Each | 1395.9 | 1395.9 | 50.0 | False | None | None | False | None | False | 69795.0 | 0 |
3950536 | 152986 | None | code163 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1838.1 | 1838.1 | 50.0 | False | None | None | False | None | False | 91905.0 | 0 |
3950537 | 152986 | None | code164 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' - 34 -36watt | No | 5008.3 | 5008.3 | 100.0 | False | None | None | False | None | False | 500830.0 | 0 |
3950538 | 152986 | None | code165 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete..15/12" Sweep (450 mm) | Each | 4890.6 | 4890.6 | 15.0 | False | None | None | False | None | False | 73359.0 | 0 |
3950539 | 152986 | None | code166 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 4733.3 | 4733.3 | 50.0 | False | None | None | False | None | False | 236665.0 | 0 |
3950540 | 152986 | None | code167 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep | Each | 2741.2 | 2741.2 | 5.0 | False | None | None | False | None | False | 13706.0 | 0 |
3950541 | 152986 | None | code168 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 134.2 | 134.2 | 200.0 | False | None | None | False | None | False | 26840.0 | 0 |
3950542 | 152986 | None | code169 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 346.5 | 346.5 | 50.0 | False | None | None | False | None | False | 17325.0 | 0 |
3950543 | 152986 | None | code170 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 777.7 | 777.7 | 10.0 | False | None | None | False | None | False | 7777.0 | 0 |
3950544 | 152986 | None | code171 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 539.0 | 539.0 | 50.0 | False | None | None | False | None | False | 26950.0 | 0 |
3950545 | 152986 | None | code172 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. | Each | 270.6 | 270.6 | 10.0 | False | None | None | False | None | False | 2706.0 | 0 |
3950546 | 152986 | None | code173 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG | Sqm | 0.55 | 0.55 | 500000.0 | False | None | None | False | None | False | 275000.0 | 0 |
3950547 | 152986 | None | code174 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Strips | Mtr | 2711.5 | 2711.5 | 32.0 | False | None | None | False | None | False | 86768.0 | 0 |
3950548 | 152986 | None | code175 | 250 A 4 x 30 x 10 mm Aluminium Strips | Mtr | 3778.5 | 3778.5 | 22.0 | False | None | None | False | None | False | 83127.0 | 0 |
3950549 | 152986 | None | code176 | 600 A 4 x 75 x 10 mm Aluminium Strips | Mtr | 6187.5 | 6187.5 | 18.0 | False | None | None | False | None | False | 111375.0 | 0 |
3950550 | 152986 | None | code177 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50 x 50 x 6 mm | Mtr | 434.5 | 434.5 | 40.0 | False | None | None | False | None | False | 17380.0 | 0 |
3950551 | 152986 | None | code178 | 75x75x6mm | Mtr | 610.5 | 610.5 | 30.0 | False | None | None | False | None | False | 18315.0 | 0 |
3950552 | 152986 | None | code179 | 50 x 100 x 50 x 6 mm C channel | Mtr | 831.6 | 831.6 | 40.0 | False | None | None | False | None | False | 33264.0 | 0 |
3950553 | 152986 | None | code180 | 75x150x75x6mm C channel | Mtr | 1018.6 | 1018.6 | 20.0 | False | None | None | False | None | False | 20372.0 | 0 |
3950554 | 152986 | None | code181 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA | Each | 9335.7 | 9335.7 | 2.0 | False | None | None | False | None | False | 18671.4 | 0 |
3950555 | 152986 | None | code182 | 125 A 25 kA | Each | 11375.1 | 11375.1 | 4.0 | False | None | None | False | None | False | 45500.4 | 0 |
3950556 | 152986 | None | code183 | 200Amps 36kA | Each | 23530.1 | 23530.1 | 4.0 | False | None | None | False | None | False | 94120.4 | 0 |
3950557 | 152986 | None | code184 | 400-500 A 50 Ka | Each | 33122.1 | 33122.1 | 3.0 | False | None | None | False | None | False | 99366.3 | 0 |
3950558 | 152986 | None | code185 | Suppiying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1873.3 | 1873.3 | 4.0 | False | None | None | False | None | False | 7493.2 | 0 |
3950559 | 152986 | None | code186 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | Each | 10180.5 | 10180.5 | 5.0 | False | None | None | False | None | False | 50902.5 | 0 |
3950560 | 152986 | None | code187 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 10246.5 | 10246.5 | 5.0 | False | None | None | False | None | False | 51232.5 | 0 |
3950561 | 152986 | None | code188 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Each | 566.5 | 566.5 | 50.0 | False | None | None | False | None | False | 28325.0 | 0 |
3950562 | 152986 | None | code189 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 618.2 | 618.2 | 15.0 | False | None | None | False | None | False | 9273.0 | 0 |
3950563 | 152986 | None | code190 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. | Each | 23804.0 | 23804.0 | 1.0 | False | None | None | False | None | False | 23804.0 | 0 |
3950564 | 152986 | None | code191 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery | Kvar | 528.0 | 528.0 | 50.0 | False | None | None | False | None | False | 26400.0 | 0 |
3950565 | 152986 | None | code192 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 60 Amps | Each | 6545.0 | 6545.0 | 5.0 | False | None | None | False | None | False | 32725.0 | 0 |
3950566 | 152986 | None | code193 | Supplying of on load change over switches 4poles, AC-23 A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 400 A | Each | 36236.2 | 36236.2 | 1.0 | False | None | None | False | None | False | 36236.2 | 0 |
3950567 | 152986 | None | code194 | Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., | Each | 1463.0 | 1463.0 | 2.0 | False | None | None | False | None | False | 2926.0 | 0 |
3950568 | 152986 | None | code195 | Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog type Ammeter. | Each | 576.4 | 576.4 | 3.0 | False | None | None | False | None | False | 1729.2 | 0 |
3950569 | 152986 | None | code196 | Supplying, fixing & wiring rotary selector switch suitable for Ammeter. | Each | 220.0 | 220.0 | 3.0 | False | None | None | False | None | False | 660.0 | 0 |
3950570 | 152986 | None | code197 | Supplying, fixing & wiring 0 to 600Volts 96X96mm AC Voltmeter on existing panel/wood board. | Each | 497.2 | 497.2 | 3.0 | False | None | None | False | None | False | 1491.6 | 0 |
3950571 | 152986 | None | code198 | Supplying, fixing & wiring rotary selector switch suitable for Voltmeter. | Each | 176.0 | 176.0 | 6.0 | False | None | None | False | None | False | 1056.0 | 0 |