4003017 | 154899 | None | code01 | GROUND FLOOR-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 229.8635 | False | None | None | False | None | False | 24149.45931 | 0 |
4003018 | 154899 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 25.51 | False | None | None | False | None | False | 9537.9339 | 0 |
4003019 | 154899 | None | code03 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. | Cum | 139.05 | 139.05 | 45.51 | False | None | None | False | None | False | 6328.1655 | 0 |
4003020 | 154899 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 152.0 | False | None | None | False | None | False | 18474.08 | 0 |
4003021 | 154899 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 114.8 | False | None | None | False | None | False | 31452.904 | 0 |
4003022 | 154899 | None | code06 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 140.22 | False | None | None | False | None | False | 68458.2084 | 0 |
4003023 | 154899 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 35.13 | False | None | None | False | None | False | 216705.3771 | 0 |
4003024 | 154899 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS | Cum | 6721.86 | 6721.86 | 42.48 | False | None | None | False | None | False | 285544.6128 | 0 |
4003025 | 154899 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.LIFT WALL & PEDESTAL | Cum | 7178.69 | 7178.69 | 3.01 | False | None | None | False | None | False | 21607.8569 | 0 |
4003026 | 154899 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.COLUMNS | Cum | 11982.09 | 11982.09 | 8.64 | False | None | None | False | None | False | 103525.2576 | 0 |
4003027 | 154899 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.PLINTH BEAM | Cum | 10572.44 | 10572.44 | 33.47 | False | None | None | False | None | False | 353859.5668 | 0 |
4003028 | 154899 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC BEAMS | Cum | 11277.26 | 11277.26 | 18.86 | False | None | None | False | None | False | 212689.1236 | 0 |
4003029 | 154899 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC SLAB | Cum | 10572.44 | 10572.44 | 34.66 | False | None | None | False | None | False | 366440.7704 | 0 |
4003030 | 154899 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.LINTELS | Cum | 11277.26 | 11277.26 | 3.42 | False | None | None | False | None | False | 38568.2292 | 0 |
4003031 | 154899 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.STAIRCSE | Cum | 10572.44 | 10572.44 | 3.78 | False | None | None | False | None | False | 39963.8232 | 0 |
4003032 | 154899 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork | Cum | 9901.91 | 9901.91 | 2.8 | False | None | None | False | None | False | 27725.348 | 0 |
4003033 | 154899 | None | code17 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 19.37 | False | None | None | False | None | False | 1784765.5527 | 0 |
4003034 | 154899 | None | code18 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 4.37 | False | None | None | False | None | False | 28757.5279 | 0 |
4003035 | 154899 | None | code19 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 275.87 | False | None | None | False | None | False | 372231.391 | 0 |
4003036 | 154899 | None | code20 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1137.12 | 1137.12 | 47.03 | False | None | None | False | None | False | 53478.7536 | 0 |
4003037 | 154899 | None | code21 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial | Sqm | 3421.66 | 3421.66 | 11.52 | False | None | None | False | None | False | 39417.5232 | 0 |
4003038 | 154899 | None | code22 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.81 | False | None | None | False | None | False | 82441.3545 | 0 |
4003039 | 154899 | None | code23 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1046.48 | 1046.48 | 4.0 | False | None | None | False | None | False | 4185.92 | 0 |
4003040 | 154899 | None | code24 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm | No | 566.5 | 566.5 | 8.0 | False | None | None | False | None | False | 4532.0 | 0 |
4003041 | 154899 | None | code25 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm | No | 386.25 | 386.25 | 4.0 | False | None | None | False | None | False | 1545.0 | 0 |
4003042 | 154899 | None | code26 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm | No | 154.5 | 154.5 | 8.0 | False | None | None | False | None | False | 1236.0 | 0 |
4003043 | 154899 | None | code27 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm | No | 72.1 | 72.1 | 16.0 | False | None | None | False | None | False | 1153.6 | 0 |
4003044 | 154899 | None | code28 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm | No | 103.0 | 103.0 | 4.0 | False | None | None | False | None | False | 412.0 | 0 |
4003045 | 154899 | None | code29 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | No | 1083.56 | 1083.56 | 4.0 | False | None | None | False | None | False | 4334.24 | 0 |
4003046 | 154899 | None | code30 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | No | 61.8 | 61.8 | 24.0 | False | None | None | False | None | False | 1483.2 | 0 |
4003047 | 154899 | None | code31 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | m | 53.56 | 53.56 | 24.0 | False | None | None | False | None | False | 1285.44 | 0 |
4003048 | 154899 | None | code32 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 54.59 | 54.59 | 27.65 | False | None | None | False | None | False | 1509.4135 | 0 |
4003049 | 154899 | None | code33 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 697.31 | 697.31 | 27.65 | False | None | None | False | None | False | 19280.6215 | 0 |
4003050 | 154899 | None | code34 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5551.7 | 5551.7 | 24.3 | False | None | None | False | None | False | 134906.31 | 0 |
4003051 | 154899 | None | code35 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5890.57 | 5890.57 | 4.32 | False | None | None | False | None | False | 25447.2624 | 0 |
4003052 | 154899 | None | code36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 601.02 | False | None | None | False | None | False | 104000.5008 | 0 |
4003053 | 154899 | None | code37 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 51.5 | 51.5 | 28.62 | False | None | None | False | None | False | 1473.93 | 0 |
4003054 | 154899 | None | code38 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 118.45 | 118.45 | 28.62 | False | None | None | False | None | False | 3390.039 | 0 |
4003055 | 154899 | None | code39 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm | m | 723.06 | 723.06 | 28.5 | False | None | None | False | None | False | 20607.21 | 0 |
4003056 | 154899 | None | code40 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness | Sqm | 3589.55 | 3589.55 | 7.88 | False | None | None | False | None | False | 28285.654 | 0 |
4003057 | 154899 | None | code41 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | No | 1147.42 | 1147.42 | 4.0 | False | None | None | False | None | False | 4589.68 | 0 |
4003058 | 154899 | None | code42 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) | Sqm | 321.36 | 321.36 | 302.34 | False | None | None | False | None | False | 97159.9824 | 0 |
4003059 | 154899 | None | code43 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 217.33 | 217.33 | 307.78 | False | None | None | False | None | False | 66889.8274 | 0 |
4003060 | 154899 | None | code44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 610.12 | False | None | None | False | None | False | 62842.36 | 0 |
4003061 | 154899 | None | code45 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 359.47 | 359.47 | 183.86 | False | None | None | False | None | False | 66092.1542 | 0 |
4003062 | 154899 | None | code46 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 364.62 | 364.62 | 23.13 | False | None | None | False | None | False | 8433.6606 | 0 |
4003063 | 154899 | None | code47 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | m | 53.56 | 53.56 | 316.0 | False | None | None | False | None | False | 16924.96 | 0 |
4003064 | 154899 | None | code48 | Providing and fixing suitable Plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment | m | 39.14 | 39.14 | 264.0 | False | None | None | False | None | False | 10332.96 | 0 |
4003065 | 154899 | None | code49 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1210.25 | 1210.25 | 90.37 | False | None | None | False | None | False | 109370.2925 | 0 |
4003066 | 154899 | None | code50 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2937.56 | 2937.56 | 48.51 | False | None | None | False | None | False | 142501.0356 | 0 |
4003067 | 154899 | None | code51 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5487.84 | 5487.84 | 26.33 | False | None | None | False | None | False | 144494.8272 | 0 |
4003068 | 154899 | None | code52 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 | Sqm | 4126.18 | 4126.18 | 6.12 | False | None | None | False | None | False | 25252.2216 | 0 |
4003069 | 154899 | None | code53 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 303.85 | 303.85 | 138.53 | False | None | None | False | None | False | 42092.3405 | 0 |
4003070 | 154899 | None | code54 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) | Sqm | 633.45 | 633.45 | 53.3 | False | None | None | False | None | False | 33762.885 | 0 |
4003071 | 154899 | None | code55 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 915.67 | 915.67 | 35.0 | False | None | None | False | None | False | 32048.45 | 0 |
4003072 | 154899 | None | code56 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1492.47 | 1492.47 | 138.53 | False | None | None | False | None | False | 206751.8691 | 0 |
4003073 | 154899 | None | code57 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 140.08 | 140.08 | 745.5 | False | None | None | False | None | False | 104429.64 | 0 |
4003074 | 154899 | None | code58 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 130.81 | 130.81 | 1170.82 | False | None | None | False | None | False | 153154.9642 | 0 |
4003075 | 154899 | None | code59 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 160.68 | 160.68 | 183.86 | False | None | None | False | None | False | 29542.6248 | 0 |
4003076 | 154899 | None | code60 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 291.49 | 291.49 | 91.93 | False | None | None | False | None | False | 26796.6757 | 0 |
4003077 | 154899 | None | code61 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2077.51 | 2077.51 | 10.5 | False | None | None | False | None | False | 21813.855 | 0 |
4003078 | 154899 | None | code62 | Providing and fixing of premium quality Terracota clay tiles for cladding of size 12x2x2 inches with single hole on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 2024.98 | 2024.98 | 208.8 | False | None | None | False | None | False | 422815.824 | 0 |
4003079 | 154899 | None | code63 | Supplying & Installing Internal Signage boards Room Signage of size 600xl50mm as approved by Architect & Engineer In change | No | 4300.0 | 4300.0 | 5.0 | False | None | None | False | None | False | 21500.0 | 0 |
4003080 | 154899 | None | code64 | FIRST FLOOR---Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.COLUMNS | Cum | 12101.91 | 12101.91 | 7.49 | False | None | None | False | None | False | 90643.3059 | 0 |
4003081 | 154899 | None | code65 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC BEAMS | Cum | 11390.04 | 11390.04 | 26.84 | False | None | None | False | None | False | 305708.6736 | 0 |
4003082 | 154899 | None | code66 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC SLAB | Cum | 10678.16 | 10678.16 | 51.57 | False | None | None | False | None | False | 550672.7112 | 0 |
4003083 | 154899 | None | code67 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.LINTELS | Cum | 11390.04 | 11390.04 | 3.77 | False | None | None | False | None | False | 42940.4508 | 0 |
4003084 | 154899 | None | code68 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.STAIRCSE | Cum | 10678.16 | 10678.16 | 3.63 | False | None | None | False | None | False | 38761.7208 | 0 |
4003085 | 154899 | None | code69 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork | Cum | 10000.92 | 10000.92 | 3.24 | False | None | None | False | None | False | 32402.9808 | 0 |
4003086 | 154899 | None | code70 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93062.12 | 93062.12 | 14.46 | False | None | None | False | None | False | 1345678.2552 | 0 |
4003087 | 154899 | None | code71 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1362.79 | 1362.79 | 395.43 | False | None | None | False | None | False | 538888.0497 | 0 |
4003088 | 154899 | None | code72 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1148.49 | 1148.49 | 9.9 | False | None | None | False | None | False | 11370.051 | 0 |
4003089 | 154899 | None | code73 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial | Sqm | 3455.88 | 3455.88 | 11.52 | False | None | None | False | None | False | 39811.7376 | 0 |
4003090 | 154899 | None | code74 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 102797.24 | 102797.24 | 0.81 | False | None | None | False | None | False | 83265.7644 | 0 |
4003091 | 154899 | None | code75 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1056.94 | 1056.94 | 4.0 | False | None | None | False | None | False | 4227.76 | 0 |
4003092 | 154899 | None | code76 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm | No | 572.17 | 572.17 | 8.0 | False | None | None | False | None | False | 4577.36 | 0 |
4003093 | 154899 | None | code77 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm | No | 390.11 | 390.11 | 4.0 | False | None | None | False | None | False | 1560.44 | 0 |
4003094 | 154899 | None | code78 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm | No | 156.05 | 156.05 | 8.0 | False | None | None | False | None | False | 1248.4 | 0 |
4003095 | 154899 | None | code79 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm | No | 72.82 | 72.82 | 16.0 | False | None | None | False | None | False | 1165.12 | 0 |
4003096 | 154899 | None | code80 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm | No | 104.03 | 104.03 | 4.0 | False | None | None | False | None | False | 416.12 | 0 |
4003097 | 154899 | None | code81 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | No | 1094.4 | 1094.4 | 4.0 | False | None | None | False | None | False | 4377.6 | 0 |
4003098 | 154899 | None | code82 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | No | 62.42 | 62.42 | 24.0 | False | None | None | False | None | False | 1498.08 | 0 |
4003099 | 154899 | None | code83 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | m | 54.1 | 54.1 | 24.0 | False | None | None | False | None | False | 1298.4 | 0 |
4003100 | 154899 | None | code84 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.14 | 55.14 | 27.65 | False | None | None | False | None | False | 1524.621 | 0 |
4003101 | 154899 | None | code85 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 704.28 | 704.28 | 27.65 | False | None | None | False | None | False | 19473.342 | 0 |
4003102 | 154899 | None | code86 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5607.22 | 5607.22 | 48.6 | False | None | None | False | None | False | 272510.892 | 0 |
4003103 | 154899 | None | code87 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 174.77 | 174.77 | 1020.6 | False | None | None | False | None | False | 178370.262 | 0 |
4003104 | 154899 | None | code88 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.02 | 52.02 | 48.6 | False | None | None | False | None | False | 2528.172 | 0 |
4003105 | 154899 | None | code89 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 119.63 | 119.63 | 57.6 | False | None | None | False | None | False | 6890.688 | 0 |
4003106 | 154899 | None | code90 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | No | 1158.89 | 1158.89 | 4.0 | False | None | None | False | None | False | 4635.56 | 0 |
4003107 | 154899 | None | code91 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) | Sqm | 324.57 | 324.57 | 350.71 | False | None | None | False | None | False | 113829.9447 | 0 |
4003108 | 154899 | None | code92 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 219.5 | 219.5 | 544.01 | False | None | None | False | None | False | 119410.195 | 0 |
4003109 | 154899 | None | code93 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 104.03 | 104.03 | 894.72 | False | None | None | False | None | False | 93077.7216 | 0 |
4003110 | 154899 | None | code94 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 363.06 | 363.06 | 429.48 | False | None | None | False | None | False | 155927.0088 | 0 |
4003111 | 154899 | None | code95 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 368.27 | 368.27 | 21.6 | False | None | None | False | None | False | 7954.632 | 0 |
4003112 | 154899 | None | code96 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | m | 54.1 | 54.1 | 316.0 | False | None | None | False | None | False | 17095.6 | 0 |
4003113 | 154899 | None | code97 | Providing and fixing suitable Plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment | m | 39.53 | 39.53 | 264.0 | False | None | None | False | None | False | 10435.92 | 0 |
4003114 | 154899 | None | code98 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1222.35 | 1222.35 | 179.98 | False | None | None | False | None | False | 219998.553 | 0 |
4003115 | 154899 | None | code99 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2966.94 | 2966.94 | 82.54 | False | None | None | False | None | False | 244891.2276 | 0 |
4003116 | 154899 | None | code100 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5542.72 | 5542.72 | 26.33 | False | None | None | False | None | False | 145939.8176 | 0 |
4003117 | 154899 | None | code101 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 141.48 | 141.48 | 1176.0 | False | None | None | False | None | False | 166380.48 | 0 |
4003118 | 154899 | None | code102 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 132.12 | 132.12 | 894.72 | False | None | None | False | None | False | 118210.4064 | 0 |
4003119 | 154899 | None | code103 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 162.29 | 162.29 | 886.23 | False | None | None | False | None | False | 143826.2667 | 0 |
4003120 | 154899 | None | code104 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 294.4 | 294.4 | 443.12 | False | None | None | False | None | False | 130454.528 | 0 |
4003121 | 154899 | None | code105 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 152.92 | 152.92 | 3500.0 | False | None | None | False | None | False | 535220.0 | 0 |
4003122 | 154899 | None | code106 | Providing and fixing of premium quality Terracota clay tiles for cladding of size 12x2x2 inches with single hole on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 2045.23 | 2045.23 | 208.8 | False | None | None | False | None | False | 427044.024 | 0 |
4003123 | 154899 | None | code107 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 501.42 | 501.42 | 10.4 | False | None | None | False | None | False | 5214.768 | 0 |
4003124 | 154899 | None | code108 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2523.77 | 2523.77 | 3.45 | False | None | None | False | None | False | 8707.0065 | 0 |
4003125 | 154899 | None | code109 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 140.44 | 140.44 | 13.85 | False | None | None | False | None | False | 1945.094 | 0 |
4003126 | 154899 | None | code110 | Supplying & Installing Internal Signage boards Room Signage of size 600xl50mm as approved by Architect & Engineer In change | No | 4300.0 | 4300.0 | 5.0 | False | None | None | False | None | False | 21500.0 | 0 |
4003127 | 154899 | None | code111 | TERRACE FLOOR---Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.COLUMNS | Cum | 12341.56 | 12341.56 | 1.56 | False | None | None | False | None | False | 19252.8336 | 0 |
4003128 | 154899 | None | code112 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11259.44 | 11259.44 | 2.19 | False | None | None | False | None | False | 24658.1736 | 0 |
4003129 | 154899 | None | code113 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC BEAMS | Cum | 11615.58 | 11615.58 | 3.68 | False | None | None | False | None | False | 42745.3344 | 0 |
4003130 | 154899 | None | code114 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC SLAB | Cum | 10889.61 | 10889.61 | 3.79 | False | None | None | False | None | False | 41271.6219 | 0 |
4003131 | 154899 | None | code115 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.LINTELS | Cum | 11615.58 | 11615.58 | 0.96 | False | None | None | False | None | False | 11150.9568 | 0 |
4003132 | 154899 | None | code116 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. CILL | Cum | 11254.03 | 11254.03 | 0.62 | False | None | None | False | None | False | 6977.4986 | 0 |
4003133 | 154899 | None | code117 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 94904.93 | 94904.93 | 1.54 | False | None | None | False | None | False | 146153.5922 | 0 |
4003134 | 154899 | None | code118 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1389.78 | 1389.78 | 185.54 | False | None | None | False | None | False | 257859.7812 | 0 |
4003135 | 154899 | None | code119 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4750.71 | 4750.71 | 2.52 | False | None | None | False | None | False | 11971.7892 | 0 |
4003136 | 154899 | None | code120 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5718.25 | 5718.25 | 2.7 | False | None | None | False | None | False | 15439.275 | 0 |
4003137 | 154899 | None | code121 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 178.23 | 178.23 | 56.7 | False | None | None | False | None | False | 10105.641 | 0 |
4003138 | 154899 | None | code122 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 223.85 | 223.85 | 59.42 | False | None | None | False | None | False | 13301.167 | 0 |
4003139 | 154899 | None | code123 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) | Sqm | 331.0 | 331.0 | 81.18 | False | None | None | False | None | False | 26870.58 | 0 |
4003140 | 154899 | None | code124 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.09 | 106.09 | 140.6 | False | None | None | False | None | False | 14916.254 | 0 |
4003141 | 154899 | None | code125 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 370.25 | 370.25 | 309.98 | False | None | None | False | None | False | 114770.095 | 0 |
4003142 | 154899 | None | code126 | Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide | m | 40.31 | 40.31 | 73.2 | False | None | None | False | None | False | 2950.692 | 0 |
4003143 | 154899 | None | code127 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | m | 55.17 | 55.17 | 96.4 | False | None | None | False | None | False | 5318.388 | 0 |
4003144 | 154899 | None | code128 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 134.73 | 134.73 | 140.6 | False | None | None | False | None | False | 18943.038 | 0 |
4003145 | 154899 | None | code129 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 165.5 | 165.5 | 309.98 | False | None | None | False | None | False | 51301.69 | 0 |
4003146 | 154899 | None | code130 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 53.05 | 53.05 | 5.22 | False | None | None | False | None | False | 276.921 | 0 |
4003147 | 154899 | None | code131 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 122.0 | 122.0 | 5.22 | False | None | None | False | None | False | 636.84 | 0 |
4003148 | 154899 | None | code132 | Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 1235.95 | 1235.95 | 329.62 | False | None | None | False | None | False | 407393.839 | 0 |
4003149 | 154899 | None | code133 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6623.2 | 6623.2 | 29.92 | False | None | None | False | None | False | 198166.144 | 0 |
4003150 | 154899 | None | code134 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 308.72 | 308.72 | 72.0 | False | None | None | False | None | False | 22227.84 | 0 |
4003151 | 154899 | None | code135 | ELECTRICAL---Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 277.07 | 277.07 | 60.0 | False | None | None | False | None | False | 16624.2 | 0 |
4003152 | 154899 | None | code136 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 390.37 | 390.37 | 80.0 | False | None | None | False | None | False | 31229.6 | 0 |
4003153 | 154899 | None | code137 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 571.65 | 571.65 | 90.0 | False | None | None | False | None | False | 51448.5 | 0 |
4003154 | 154899 | None | code138 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 697.31 | 697.31 | 20.0 | False | None | None | False | None | False | 13946.2 | 0 |
4003155 | 154899 | None | code139 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches | Point | 1018.67 | 1018.67 | 4.5 | False | None | None | False | None | False | 4584.015 | 0 |
4003156 | 154899 | None | code140 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way | Each | 142.14 | 142.14 | 35.0 | False | None | None | False | None | False | 4974.9 | 0 |
4003157 | 154899 | None | code141 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way | Each | 163.77 | 163.77 | 40.0 | False | None | None | False | None | False | 6550.8 | 0 |
4003158 | 154899 | None | code142 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 182.31 | 182.31 | 40.0 | False | None | None | False | None | False | 7292.4 | 0 |
4003159 | 154899 | None | code143 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 226.6 | 226.6 | 30.0 | False | None | None | False | None | False | 6798.0 | 0 |
4003160 | 154899 | None | code144 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 268.83 | 268.83 | 60.0 | False | None | None | False | None | False | 16129.8 | 0 |
4003161 | 154899 | None | code145 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 328.57 | 328.57 | 60.0 | False | None | None | False | None | False | 19714.2 | 0 |
4003162 | 154899 | None | code146 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 141.11 | 141.11 | 35.0 | False | None | None | False | None | False | 4938.85 | 0 |
4003163 | 154899 | None | code147 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 165.83 | 165.83 | 40.0 | False | None | None | False | None | False | 6633.2 | 0 |
4003164 | 154899 | None | code148 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 180.25 | 180.25 | 35.0 | False | None | None | False | None | False | 6308.75 | 0 |
4003165 | 154899 | None | code149 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 241.02 | 241.02 | 35.0 | False | None | None | False | None | False | 8435.7 | 0 |
4003166 | 154899 | None | code150 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 292.52 | 292.52 | 60.0 | False | None | None | False | None | False | 17551.2 | 0 |
4003167 | 154899 | None | code151 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 354.32 | 354.32 | 60.0 | False | None | None | False | None | False | 21259.2 | 0 |
4003168 | 154899 | None | code152 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 105.06 | 105.06 | 200.0 | False | None | None | False | None | False | 21012.0 | 0 |
4003169 | 154899 | None | code153 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch | Each | 170.98 | 170.98 | 13.5 | False | None | None | False | None | False | 2308.23 | 0 |
4003170 | 154899 | None | code154 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 176.13 | 176.13 | 90.0 | False | None | None | False | None | False | 15851.7 | 0 |
4003171 | 154899 | None | code155 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 367.71 | 367.71 | 90.0 | False | None | None | False | None | False | 33093.9 | 0 |
4003172 | 154899 | None | code156 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 335.78 | 335.78 | 4.5 | False | None | None | False | None | False | 1511.01 | 0 |
4003173 | 154899 | None | code157 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 243.08 | 243.08 | 10.5 | False | None | None | False | None | False | 2552.34 | 0 |
4003174 | 154899 | None | code158 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Each | 185.4 | 185.4 | 6.0 | False | None | None | False | None | False | 1112.4 | 0 |
4003175 | 154899 | None | code159 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 120.51 | 120.51 | 40.0 | False | None | None | False | None | False | 4820.4 | 0 |
4003176 | 154899 | None | code160 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Mtr | 67.98 | 67.98 | 1200.0 | False | None | None | False | None | False | 81576.0 | 0 |
4003177 | 154899 | None | code161 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Mtr | 80.34 | 80.34 | 1200.0 | False | None | None | False | None | False | 96408.0 | 0 |
4003178 | 154899 | None | code162 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick | Mtr | 106.09 | 106.09 | 200.0 | False | None | None | False | None | False | 21218.0 | 0 |
4003179 | 154899 | None | code163 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 70.04 | 70.04 | 800.0 | False | None | None | False | None | False | 56032.0 | 0 |
4003180 | 154899 | None | code164 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 81.37 | 81.37 | 900.0 | False | None | None | False | None | False | 73233.0 | 0 |
4003181 | 154899 | None | code165 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 101.97 | 101.97 | 150.0 | False | None | None | False | None | False | 15295.5 | 0 |
4003182 | 154899 | None | code166 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm | Mtr | 26.78 | 26.78 | 900.0 | False | None | None | False | None | False | 24102.0 | 0 |
4003183 | 154899 | None | code167 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm | Mtr | 43.26 | 43.26 | 1800.0 | False | None | None | False | None | False | 77868.0 | 0 |
4003184 | 154899 | None | code168 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm | Mtr | 64.89 | 64.89 | 350.0 | False | None | None | False | None | False | 22711.5 | 0 |
4003185 | 154899 | None | code169 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm | Mtr | 94.76 | 94.76 | 800.0 | False | None | None | False | None | False | 75808.0 | 0 |
4003186 | 154899 | None | code170 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N | Each | 2398.87 | 2398.87 | 10.0 | False | None | None | False | None | False | 23988.7 | 0 |
4003187 | 154899 | None | code171 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 427.45 | 427.45 | 80.0 | False | None | None | False | None | False | 34196.0 | 0 |
4003188 | 154899 | None | code172 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole | Each | 4405.31 | 4405.31 | 12.0 | False | None | None | False | None | False | 52863.72 | 0 |
4003189 | 154899 | None | code173 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm | Km | 143735.47 | 143735.47 | 0.38 | False | None | None | False | None | False | 54619.4786 | 0 |
4003190 | 154899 | None | code174 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm | Km | 21512.58 | 21512.58 | 0.38 | False | None | None | False | None | False | 8174.7804 | 0 |
4003191 | 154899 | None | code175 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia | Each | 120.51 | 120.51 | 9.0 | False | None | None | False | None | False | 1084.59 | 0 |
4003192 | 154899 | None | code176 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 25 sqmm Long Barrel | Each | 24.72 | 24.72 | 18.0 | False | None | None | False | None | False | 444.96 | 0 |
4003193 | 154899 | None | code177 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 3615.3 | 3615.3 | 4.5 | False | None | None | False | None | False | 16268.85 | 0 |
4003194 | 154899 | None | code178 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip | Mtr | 84.46 | 84.46 | 67.5 | False | None | None | False | None | False | 5701.05 | 0 |
4003195 | 154899 | None | code179 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 710.7 | 710.7 | 337.5 | False | None | None | False | None | False | 239861.25 | 0 |
4003196 | 154899 | None | code180 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 911.55 | 911.55 | 22.5 | False | None | None | False | None | False | 20509.875 | 0 |
4003197 | 154899 | None | code181 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K | Each | 153.47 | 153.47 | 12.0 | False | None | None | False | None | False | 1841.64 | 0 |
4003198 | 154899 | None | code182 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K | Each | 277.07 | 277.07 | 55.5 | False | None | None | False | None | False | 15377.385 | 0 |
4003199 | 154899 | None | code183 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts | No | 4144.72 | 4144.72 | 4.5 | False | None | None | False | None | False | 18651.24 | 0 |
4003200 | 154899 | None | code184 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1536.76 | 1536.76 | 27.0 | False | None | None | False | None | False | 41492.52 | 0 |
4003201 | 154899 | None | code185 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) | Each | 2757.31 | 2757.31 | 90.0 | False | None | None | False | None | False | 248157.9 | 0 |
4003202 | 154899 | None | code186 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 64.89 | 64.89 | 45.0 | False | None | None | False | None | False | 2920.05 | 0 |
4003203 | 154899 | None | code187 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 125.66 | 125.66 | 120.0 | False | None | None | False | None | False | 15079.2 | 0 |
4003204 | 154899 | None | code188 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. | Each | 324.45 | 324.45 | 240.0 | False | None | None | False | None | False | 77868.0 | 0 |
4003205 | 154899 | None | code189 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 728.21 | 728.21 | 21.0 | False | None | None | False | None | False | 15292.41 | 0 |
4003206 | 154899 | None | code190 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length | Each | 1504.83 | 1504.83 | 3.0 | False | None | None | False | None | False | 4514.49 | 0 |
4003207 | 154899 | None | code191 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 166.86 | 166.86 | 3.0 | False | None | None | False | None | False | 500.58 | 0 |
4003208 | 154899 | None | code192 | L.T PANEL-Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG | Sq CM | 0.44 | 0.44 | 150000.0 | False | None | None | False | None | False | 66000.0 | 0 |
4003209 | 154899 | None | code193 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminum Strips | Mtr | 2538.95 | 2538.95 | 6.0 | False | None | None | False | None | False | 15233.7 | 0 |
4003210 | 154899 | None | code194 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm | Mtr | 314.15 | 314.15 | 12.0 | False | None | None | False | None | False | 3769.8 | 0 |
4003211 | 154899 | None | code195 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel | Mtr | 778.68 | 778.68 | 12.0 | False | None | None | False | None | False | 9344.16 | 0 |
4003212 | 154899 | None | code196 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA | Each | 8741.61 | 8741.61 | 1.5 | False | None | None | False | None | False | 13112.415 | 0 |
4003213 | 154899 | None | code197 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 427.45 | 427.45 | 4.5 | False | None | None | False | None | False | 1923.525 | 0 |
4003214 | 154899 | None | code198 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 3180.64 | 3180.64 | 3.0 | False | None | None | False | None | False | 9541.92 | 0 |
4003215 | 154899 | None | code199 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP | Each | 761.17 | 761.17 | 9.0 | False | None | None | False | None | False | 6850.53 | 0 |
4003216 | 154899 | None | code200 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9594.45 | 9594.45 | 1.5 | False | None | None | False | None | False | 14391.675 | 0 |
4003217 | 154899 | None | code201 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Each | 530.45 | 530.45 | 4.5 | False | None | None | False | None | False | 2387.025 | 0 |
4003218 | 154899 | None | code202 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 578.86 | 578.86 | 4.5 | False | None | None | False | None | False | 2604.87 | 0 |
4003219 | 154899 | None | code203 | INTERNAL WATER SUPPLY--40mm dia pipes, From wash basin waste lines-Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work | m | 313.12 | 313.12 | 40.0 | False | None | None | False | None | False | 12524.8 | 0 |
4003220 | 154899 | None | code204 | 50mm dia pipes, From sink & urinal waste lines-Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work | m | 397.58 | 397.58 | 30.0 | False | None | None | False | None | False | 11927.4 | 0 |
4003221 | 154899 | None | code205 | 75mm nominal dia pipes -Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) | m | 297.67 | 297.67 | 50.0 | False | None | None | False | None | False | 14883.5 | 0 |
4003222 | 154899 | None | code206 | 110mm nominal dia pipes -Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) | m | 396.55 | 396.55 | 60.0 | False | None | None | False | None | False | 23793.0 | 0 |
4003223 | 154899 | None | code207 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete | Each | 251.32 | 251.32 | 15.0 | False | None | None | False | None | False | 3769.8 | 0 |
4003224 | 154899 | None | code208 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 75 mm diameter | m | 202.91 | 202.91 | 40.0 | False | None | None | False | None | False | 8116.4 | 0 |
4003225 | 154899 | None | code209 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete. | Each | 1256.6 | 1256.6 | 1.0 | False | None | None | False | None | False | 1256.6 | 0 |
4003226 | 154899 | None | code210 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 | Each | 638.6 | 638.6 | 1.0 | False | None | None | False | None | False | 638.6 | 0 |
4003227 | 154899 | None | code211 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid | Each | 6156.31 | 6156.31 | 2.0 | False | None | None | False | None | False | 12312.62 | 0 |
4003228 | 154899 | None | code212 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5030.52 | 5030.52 | 3.0 | False | None | None | False | None | False | 15091.56 | 0 |
4003229 | 154899 | None | code213 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 4587.62 | 4587.62 | 2.0 | False | None | None | False | None | False | 9175.24 | 0 |
4003230 | 154899 | None | code214 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Each | 3174.46 | 3174.46 | 1.0 | False | None | None | False | None | False | 3174.46 | 0 |
4003231 | 154899 | None | code215 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos | 746.75 | 746.75 | 12.0 | False | None | None | False | None | False | 8961.0 | 0 |
4003232 | 154899 | None | code216 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore | Nos | 294.58 | 294.58 | 2.0 | False | None | None | False | None | False | 589.16 | 0 |
4003233 | 154899 | None | code217 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. | Each | 834.3 | 834.3 | 2.0 | False | None | None | False | None | False | 1668.6 | 0 |
4003234 | 154899 | None | code218 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) | Each | 85.49 | 85.49 | 2.0 | False | None | None | False | None | False | 170.98 | 0 |
4003235 | 154899 | None | code219 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, eTFective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g | Each | 315.18 | 315.18 | 2.0 | False | None | None | False | None | False | 630.36 | 0 |
4003236 | 154899 | None | code220 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g | Each | 92.7 | 92.7 | 2.0 | False | None | None | False | None | False | 185.4 | 0 |
4003237 | 154899 | None | code221 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications. | Sqm | 4435.18 | 4435.18 | 3.0 | False | None | None | False | None | False | 13305.54 | 0 |
4003238 | 154899 | None | code222 | WATER SUPPLY-15 mm nominal dia Pipes-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. | m | 318.27 | 318.27 | 150.0 | False | None | None | False | None | False | 47740.5 | 0 |
4003239 | 154899 | None | code223 | 20 mm nominal dia Pipes-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. | m | 390.37 | 390.37 | 100.0 | False | None | None | False | None | False | 39037.0 | 0 |
4003240 | 154899 | None | code224 | 25 mm nominal dia pipes-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. | m | 491.31 | 491.31 | 100.0 | False | None | None | False | None | False | 49131.0 | 0 |
4003241 | 154899 | None | code225 | 32 mm nominal dia pipes-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. | m | 573.71 | 573.71 | 100.0 | False | None | None | False | None | False | 57371.0 | 0 |
4003242 | 154899 | None | code226 | 25 mm nominal dia Pipes-Shafts & Terrace-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work | m | 304.88 | 304.88 | 120.0 | False | None | None | False | None | False | 36585.6 | 0 |
4003243 | 154899 | None | code227 | 32 mm nominal dia Pipes-Shafts & Terrace-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work | m | 383.16 | 383.16 | 60.0 | False | None | None | False | None | False | 22989.6 | 0 |
4003244 | 154899 | None | code228 | 40 mm nominal dia Pipes-Shafts & Terrace-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work | m | 491.31 | 491.31 | 120.0 | False | None | None | False | None | False | 58957.2 | 0 |
4003245 | 154899 | None | code229 | 25 mm nominal bore-Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : | No | 341.96 | 341.96 | 4.0 | False | None | None | False | None | False | 1367.84 | 0 |
4003246 | 154899 | None | code230 | 32 mm nominal bore-Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : | No | 615.94 | 615.94 | 4.0 | False | None | None | False | None | False | 2463.76 | 0 |
4003247 | 154899 | None | code231 | 40 mm nominal bore-Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : | No | 723.06 | 723.06 | 5.0 | False | None | None | False | None | False | 3615.3 | 0 |
4003248 | 154899 | None | code232 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | l | 9.27 | 9.27 | 3000.0 | False | None | None | False | None | False | 27810.0 | 0 |
4003249 | 154899 | None | code233 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 151.41 | 151.41 | 25.0 | False | None | None | False | None | False | 3785.25 | 0 |
4003250 | 154899 | None | code234 | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent) | No | 1543.0 | 1543.0 | 5.0 | False | None | None | False | None | False | 7715.0 | 0 |
4003251 | 154899 | None | code235 | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards | No | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 |
4003252 | 154899 | None | code236 | Air Vent Cowel 75mm | No | 350.0 | 350.0 | 2.0 | False | None | None | False | None | False | 700.0 | 0 |
4003253 | 154899 | None | code237 | Air Vent Cowel 110mm | No | 500.0 | 500.0 | 2.0 | False | None | None | False | None | False | 1000.0 | 0 |
4003254 | 154899 | None | code238 | EXTERNAL WATER SUPPLY---Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 128.7 | False | None | None | False | None | False | 13521.222 | 0 |
4003255 | 154899 | None | code239 | Filling approved earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 90.09 | False | None | None | False | None | False | 24682.8582 | 0 |
4003256 | 154899 | None | code240 | Pipes of SN8 Self Fit - 160mm dia.--Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for: | m | 635.51 | 635.51 | 105.0 | False | None | None | False | None | False | 66728.55 | 0 |
4003257 | 154899 | None | code241 | Pipes of SN4, 160mm dia.--Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for | m | 593.28 | 593.28 | 80.0 | False | None | None | False | None | False | 47462.4 | 0 |
4003258 | 154899 | None | code242 | Constructing brick masonry chamber of internal dimension 600x600mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | Each | 5617.62 | 5617.62 | 10.0 | False | None | None | False | None | False | 56176.2 | 0 |
4003259 | 154899 | None | code243 | Constructing brick masonry chamber of internal dimension 600x600mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) | Each | 5617.62 | 5617.62 | 5.0 | False | None | None | False | None | False | 28088.1 | 0 |
4003260 | 154899 | None | code244 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design: | Nos | 2658.43 | 2658.43 | 5.0 | False | None | None | False | None | False | 13292.15 | 0 |
4003261 | 154899 | None | code245 | 50 mm nominal dia Pipes--Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work | m | 742.63 | 742.63 | 200.0 | False | None | None | False | None | False | 148526.0 | 0 |
4003262 | 154899 | None | code246 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Domestic Sump To OHT) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) | Each | 16078.3 | 16078.3 | 2.0 | False | None | None | False | None | False | 32156.6 | 0 |
4003263 | 154899 | None | code247 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 2.0 | False | None | None | False | None | False | 13390.0 | 0 |
4003264 | 154899 | None | code248 | SUMP TANK--Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 404.79 | 404.79 | 0.29 | False | None | None | False | None | False | 117.3891 | 0 |
4003265 | 154899 | None | code249 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 65.61 | False | None | None | False | None | False | 6892.9866 | 0 |
4003266 | 154899 | None | code250 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 7.29 | False | None | None | False | None | False | 2725.6581 | 0 |
4003267 | 154899 | None | code251 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum | Cum | 139.05 | 139.05 | 75.0 | False | None | None | False | None | False | 10428.75 | 0 |
4003268 | 154899 | None | code252 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 26.35 | False | None | None | False | None | False | 7219.373 | 0 |
4003269 | 154899 | None | code253 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 2.12 | False | None | None | False | None | False | 13077.5804 | 0 |
4003270 | 154899 | None | code254 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.-SUMP BASE SLAB | Cum | 6721.86 | 6721.86 | 4.84 | False | None | None | False | None | False | 32533.8024 | 0 |
4003271 | 154899 | None | code255 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.SUMP WALL | Cum | 11094.34 | 11094.34 | 8.8 | False | None | None | False | None | False | 97630.192 | 0 |
4003272 | 154899 | None | code256 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.SUMP TOP SLAB | Cum | 9789.12 | 9789.12 | 3.2 | False | None | None | False | None | False | 31325.184 | 0 |
4003273 | 154899 | None | code257 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Tonne | 81381.33 | 81381.33 | 1.83 | False | None | None | False | None | False | 148927.8339 | 0 |
4003274 | 154899 | None | code258 | Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. | Sqm | 1723.19 | 1723.19 | 56.0 | False | None | None | False | None | False | 96498.64 | 0 |
4003275 | 154899 | None | code259 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 382.13 | 382.13 | 112.0 | False | None | None | False | None | False | 42798.56 | 0 |
4003276 | 154899 | None | code260 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 118.45 | 118.45 | 112.0 | False | None | None | False | None | False | 13266.4 | 0 |
4003277 | 154899 | None | code261 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 26.78 | 26.78 | 112.0 | False | None | None | False | None | False | 2999.36 | 0 |
4003278 | 154899 | None | code262 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | Nos | 2020.86 | 2020.86 | 2.0 | False | None | None | False | None | False | 4041.72 | 0 |
4003279 | 154899 | None | code263 | PAVER WORK---Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 249.26 | 249.26 | 95.2 | False | None | None | False | None | False | 23729.552 | 0 |
4003280 | 154899 | None | code264 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum & Cost of Haulage Excluding Loading and Unloading | Cum | 139.05 | 139.05 | 95.2 | False | None | None | False | None | False | 13237.56 | 0 |
4003281 | 154899 | None | code265 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 47.6 | False | None | None | False | None | False | 293628.692 | 0 |
4003282 | 154899 | None | code266 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) | Sqm | 1100.04 | 1100.04 | 476.0 | False | None | None | False | None | False | 523619.04 | 0 |
4003283 | 154899 | None | code267 | COMPOUND WALL--Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 404.79 | 404.79 | 0.24 | False | None | None | False | None | False | 97.1496 | 0 |
4003284 | 154899 | None | code268 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 97.85 | 97.85 | 7.2 | False | None | None | False | None | False | 704.52 | 0 |
4003285 | 154899 | None | code269 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 54.0 | False | None | None | False | None | False | 5673.24 | 0 |
4003286 | 154899 | None | code270 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 54.0 | False | None | None | False | None | False | 14794.92 | 0 |
4003287 | 154899 | None | code271 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 3.12 | False | None | None | False | None | False | 19246.2504 | 0 |
4003288 | 154899 | None | code272 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 11.88 | False | None | None | False | None | False | 68658.4404 | 0 |
4003289 | 154899 | None | code273 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6816.54 | 6816.54 | 10.08 | False | None | None | False | None | False | 68710.7232 | 0 |
4003290 | 154899 | None | code274 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6391.15 | 6391.15 | 4.86 | False | None | None | False | None | False | 31060.989 | 0 |
4003291 | 154899 | None | code275 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 6.48 | False | None | None | False | None | False | 42642.7416 | 0 |
4003292 | 154899 | None | code276 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 1.08 | False | None | None | False | None | False | 6915.7908 | 0 |
4003293 | 154899 | None | code277 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 359.47 | 359.47 | 28.8 | False | None | None | False | None | False | 10352.736 | 0 |
4003294 | 154899 | None | code278 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. | Kg | 140.08 | 140.08 | 2760.0 | False | None | None | False | None | False | 386620.8 | 0 |
4003295 | 154899 | None | code279 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 160.68 | 160.68 | 28.8 | False | None | None | False | None | False | 4627.584 | 0 |