createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726309302135
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd9500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-09-2024 16:30:00
tenderQueryClose24-09-2024 15:30:00
technicalBidOpenNone
publishedDate17-09-2024 10:27:36
publishedByPostRDPR_EE_DIV_BLR
publishedByUserKPE19203 - H INDUDHAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRE DIVISION BALLARI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08392266173
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1726309302182
version5
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8768
titleConstruction of Anganawadhi Building -1 at Taranagara village of Sandur Tq Ballari Dist (reserved for SC)
descriptionConstruction of Anganawadhi Building -1 at Taranagara village of Sandur Tq Ballari Dist (reserved for SC)
categoryWORKS
categoryTextWorks
ecv618376.44
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location818
locationNameRDPR Division Office Ballari
provisionalAmount733000.0
groupOverheadTotal0.0
fileNumberRDPR/2023-24/Anganawadi
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17263093020000NoneNoneBuildingsConstruction of Anganawadhi Building at Taranagara village Anganawadhi-1 in Sandur Tq Ballari Dist473933.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4007982155129NoneVol-I, Item No.-2.1.2, P.No.-15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.25.16FalseNoneNoneFalseNoneFalse30687.5520
4007983155129NonePWD SR (Vol-1) Sl No. 2.1.4 P.No-15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.850.405FalseNoneNoneFalseNoneFalse2643.779250
4007984155129None2023-2024 PWD SR (Vol-2) Sl No. 12.97.1Providing and fixing to the existing door frames 30mm Thick Glass Fibre reinforced plastic (FRP) Panelled Door Shutter of required Colour and Approved brand and manufacture made with fire retartdant garde unsaturated polyster resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS:14856 including fixing to frames.Cum3364.23364.21.52FalseNoneNoneFalseNoneFalse5113.5840
4007985155129None2023-2024 PWD SR (Vol-2) Sl No. 12.51 P.No-104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Cum1066.81066.83.0FalseNoneNoneFalseNoneFalse3200.40
4007986155129None2023-2024 PWD SR (Vol-2) Sl No. 12.97.1Providing and fixing to the existing door frames 30mm Thick Glass Fibre reinforced plastic (FRP) Panelled Door Shutter of required Colour and Approved brand and manufacture made with fire retartdant garde unsaturated polyster resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS:14856 including fixing to frames.Sqm3364.23364.26.72FalseNoneNoneFalseNoneFalse22607.4240
4007987155129None2023-2024 PWD SR (Vol-2) Sl No. 12.97.1Providing and fixing factory made single extruded wood polymer composite (WPC) solid door/ window, clerestory windows & frames/ chowkhat of frame size 62X100mmSqm737.1737.110.2FalseNoneNoneFalseNoneFalse7518.420
4007988155129None2023-2024 PWD SR (Vol-2) Sl No. 12.97.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelamSqm2484.32484.33.15FalseNoneNoneFalseNoneFalse7825.5450
4007989155129None2023-2024 PWD SR (Vol-2) Sl No.12.87 P.No.109Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass,Sqm6878.556878.556.075FalseNoneNoneFalseNoneFalse41787.191250
4007990155129None2023-2024 PWD SR (Vol-2) Sl No.12.85 P.No.109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible sizeSqm6004.956004.952.79FalseNoneNoneFalseNoneFalse16753.81050
4007991155129None2023-2024 PWD SR (Vol-2) Sl No.11.34A P.No.86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs176.4176.4186.16FalseNoneNoneFalseNoneFalse32838.6240
4007992155129None2023-2024 PWD SR (Vol-2) Sl No.8.2.1 P.No.41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75157.64FalseNoneNoneFalseNoneFalse48828.990
4007993155129None2023-2024 PWD SR (Vol-2) Sl No.8.2.1 P.No.41Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm371.7371.7170.0FalseNoneNoneFalseNoneFalse63189.00
4007994155129None2023-2024 PWD SR (Vol-2) Sl No.8.1.1 P.No.41Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7549.9698FalseNoneNoneFalseNoneFalse13379.413950
4007995155129None2023-2024 PWD SR (Vol-2) Sl No.8.2.1 P.No.41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm292.95292.9515.6FalseNoneNoneFalseNoneFalse4570.020
4007996155129None2023-2024 PWD SR (Vol-2) Sl No.8.2.2 P.No.41Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0207.61FalseNoneNoneFalseNoneFalse21799.050
4007997155129None2023-2024 PWD SR (Vol-2) Sl No.8.39 P.No.48Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm133.35133.35101.42FalseNoneNoneFalseNoneFalse13524.3570
4007998155129None2023-2024 PWD SR (Vol-2) Sl No.8.30 P.No.46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.786.49FalseNoneNoneFalseNoneFalse15801.7230
4007999155129None2023-2024 PWD SR (Vol-2) Sl No.8.40 P.No.48Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.758.86FalseNoneNoneFalseNoneFalse1069.8450
4008000155129None2023-2024 PWD SR (Vol-2) Sl No.9.12.2 P.No.60Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1202.251202.2552.425FalseNoneNoneFalseNoneFalse63027.956250
4008001155129None2023-2024 PWD SR (Vol-2) Sl No.9.11 P.No.60Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4525.154FalseNoneNoneFalseNoneFalse23480.00130
4008002155129None2023-2024 PWD SR (Vol-2) Sl No.9.24 P.No.63Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specificationsSqm1461.61461.612.03FalseNoneNoneFalseNoneFalse17583.0480
4008003155129NoneFrom GEMProviding and fixing glass/Ceramic Steel Green Dry Erase Writing BoardsSqm2175.02175.02.16FalseNoneNoneFalseNoneFalse4698.00
4008004155129None2023-2024 PWD SR (Vol-2) Sl No.11.25.2 P.No.82Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm142.8142.837.8FalseNoneNoneFalseNoneFalse5397.840
4008005155129None2023-2024 PWD SR (Vol-2) Sl No.9.24 P.No.63Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm2994.62994.61.85FalseNoneNoneFalseNoneFalse5540.010
4008006155129None2023-2024 PWD SR (Vol-2) Sl No.10.2 P.No.69Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Sqm344.4344.43.1FalseNoneNoneFalseNoneFalse1067.640
17263093020000NoneNoneBuildingsElectriacal and Water Supply Anganawadhi Building at Taranagara village Anganawadhi-1 in Sandur Tq Ballari Dista144443.24
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4008007155130NoneVol. I1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Note: Cost of De-watering upto 5 % of (A+B) may be added, where required assessment for dewatering shall be made as per site conditionCum107.1107.128.11FalseNoneNoneFalseNoneFalse3010.5810
4008008155130NoneVol. I 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.028.11FalseNoneNoneFalseNoneFalse4722.480
4008009155130NoneVol. II- 13.2.2Providing and fixing brass bib cock of approved quality 20mm nominal boreNo320.25320.253.0FalseNoneNoneFalseNoneFalse960.750
4008010155130NoneVol. II- 13.2.3Providing and fixing in position brass PUSH cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (In Hand Wash) DRNo310.8310.82.0FalseNoneNoneFalseNoneFalse621.60
4008011155130NoneVol. II-13.3.1Providing and fixing brass stop cock of approved quality 15mm nominal bore 15mm Dia Nominal BoreNo320.25320.251.0FalseNoneNoneFalseNoneFalse320.250
4008012155130NoneVol. II-13.4.3Providing and fixing brass gate valve with C.I wheel of approved quality ( screwed end ) 40mm nominal boreNo737.1737.11.0FalseNoneNoneFalseNoneFalse737.10
4008013155130NoneVol. II-13.5.3Providing and fixing brass ball valve high or low pressure with plastic float of approved quality 25mm nominal boreNo348.6348.61.0FalseNoneNoneFalseNoneFalse348.60
4008014155130NoneVol. II-13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal boreNo95.5595.551.0FalseNoneNoneFalseNoneFalse95.550
4008015155130NoneVol. II-13.32.2Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot & cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement & testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 20mm OD PipeNo397.95397.9510.0FalseNoneNoneFalseNoneFalse3979.50
4008016155130NoneVol. II-13.32.3Providing and fixing chlorinated poly veny chloride (CPVC) pipes, having terminal stability for hot & cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement & testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 25 OD pipeMtr500.85500.855.0FalseNoneNoneFalseNoneFalse2504.250
4008017155130NoneVol. II-13.32.4Providing & fixing chorinated poly venyl chloride (CPVC) pipes, having thermal stablity for hot & cold water supply, including all CPVC plain and brass threaded fittings, i.e, fixing the pipe with clamp at 1.00 spacing .This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases & making good the same including testing of joints complete as per direction of engineer in charge.( concealed work including cutting chases and making good the walls etc. 25 mm OD pipeMtr500.85500.8510.0FalseNoneNoneFalseNoneFalse5008.50
4008018155130NoneVol. V-8-T130AConstructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Inspection chamber 450x600mmEach4592.74592.72.0FalseNoneNoneFalseNoneFalse9185.40
4008019155130NoneVol. II- 13.34Providing and placing on terrace, polyethylene water storage tanks, IS: 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tankLtr9.459.45750.0FalseNoneNoneFalseNoneFalse7087.50
4008020155130NoneVol. II- 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.21.0FalseNoneNoneFalseNoneFalse5128.20
4008021155130NoneVol. II-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lidEach6095.256095.251.0FalseNoneNoneFalseNoneFalse6095.250
4008022155130NoneXLV-2Supplying and fixing of 1.5/1.1 H.P. Monolbock Pump of approved make with all accessories conforming to ISI specification including cost of all materials, labour, with all lead and lift etc. complete as per directions of the Engineer-in-cahrge of the work. - With all lead and lifts etc., complete as per specification and as per the directions of the Engineer-In-Charge of the work. XLV item no 3Unit9232.659232.651.0FalseNoneNoneFalseNoneFalse9232.650
4008023155130NoneVol. II- 14.7.7Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tapUnit2203.952203.951.0FalseNoneNoneFalseNoneFalse2203.950
4008024155130NoneVol. V-5.2-M070ARCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mmEach17221.0517221.051.0FalseNoneNoneFalseNoneFalse17221.050
4008025155130None114-11.20.3Supplying & erection of RCC rings for well steining of 0.3 Mtr Depth using M-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering, from work and plastering for both faces with C.M 1:3 proportion as per design using 6.50mm M.S. coil at the rate of 10 Kgs/ring including cost of steel and fabrication, bailing out of water, errection etc., complete iii) For 1.20 M dia (clear) rings of steining thickness 0.075 M upto 18 M depth RWS SR 2019-20 Zone-BEach1097.251097.254.0FalseNoneNoneFalseNoneFalse4389.00
4008026155130NoneVol. II-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm974.4974.43.53FalseNoneNoneFalseNoneFalse3439.6320
4008027155130None1.2.1Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thickm69.069.0130.0FalseNoneNoneFalseNoneFalse8970.00
4008028155130None1.2.1Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym81.081.030.0FalseNoneNoneFalseNoneFalse2430.00
4008029155130None1.4.1Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75x75x65mmEach106.0106.01.0FalseNoneNoneFalseNoneFalse106.00
4008030155130None1.4.2Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100x75x65mmEach118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
4008031155130None1.4.4Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mmEach161.0161.02.0FalseNoneNoneFalseNoneFalse322.00
4008032155130None1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction BoxEach49.049.03.0FalseNoneNoneFalseNoneFalse147.00
4008033155130None1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction BoxEach56.056.01.0FalseNoneNoneFalseNoneFalse56.00
4008034155130None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.Each29.029.09.0FalseNoneNoneFalseNoneFalse261.00
4008035155130None1.12Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.02.0FalseNoneNoneFalseNoneFalse234.00
4008036155130None2.2.1Point wiring Copper without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing usingf 1100v Grade , COPPER conductor flexible multistrand FRLS PVC insulated., 2x1.5 Sqm. Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. Complete for each outlet(5/2.3) Group A Short piont up to 3 Mtr from tapping piont out let via switch.Point285.0285.07.0FalseNoneNoneFalseNoneFalse1995.00
4008037155130None2.2.2Point wiring Copper without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing usingf 1100v Grade , COPPER conductor flexible multistrand FRLS PVC insulated., 2x1.5 Sqm. Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. Complete for each outlet(5/2.3) Group A Short piont up to 6 Mtr from tapping piont outPoint394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
4008038155130None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmmm26.026.0180.0FalseNoneNoneFalseNoneFalse4680.00
4008039155130None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmmm42.042.018.0FalseNoneNoneFalseNoneFalse756.00
4008040155130None3.5.1Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
4008041155130None3.5.2Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.4 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
4008042155130None3.5.3Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.8ModuleEach284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
4008043155130None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one wayEach107.1107.19.0FalseNoneNoneFalseNoneFalse963.90
4008044155130None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped fan regulatorEach374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
4008045155130None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switchEach189.0189.01.0FalseNoneNoneFalseNoneFalse189.00
4008046155130None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socketEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
4008047155130None3.7Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & completely wired on existing boxEach646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
4008048155130None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32AmpsEach241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
4008049155130None5.17.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SPEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
4008050155130None5.18.8Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.8 Way SP & NEach1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
4008051155130None5.40.2Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Stripsm3435.03435.00.5FalseNoneNoneFalseNoneFalse1717.50
4008052155130None5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy MeterEach5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
4008053155130NoneP430ASupplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaJob3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
4008054155130None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracketblades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm)Each3515.03515.01.0FalseNoneNoneFalseNoneFalse3515.00
4008055155130None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CR greater than 80. Power Input: 220-240V @ 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4 20-22Each690.0690.04.0FalseNoneNoneFalseNoneFalse2760.00
4008056155130None12.25.2Supplying and fixing of 5-80 Watts of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating. Operating voltage range from 180V to 265V, 50Hz AC power Supply 1 x4 Tube light fitting.Each520.0520.01.0FalseNoneNoneFalseNoneFalse520.00
4008057155130None13.7.1Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach63.063.03.0FalseNoneNoneFalseNoneFalse189.00
4008058155130None13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wiredEach171.0171.01.0FalseNoneNoneFalseNoneFalse171.00
4008059155130None13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each490.0490.01.0FalseNoneNoneFalseNoneFalse490.00
4008060155130None12.21Supplying of patty fitting made out of crca sheet metal body with locking type holder completely wired with HF Electronic ballast Operating voltage range from 180v to 265v 50 Hz AC Power supply exclude tubeNos461.0461.01.0FalseNoneNoneFalseNoneFalse461.00
4008061155130Nonecode 2fixing all types and all capacities of floursecnt/false ceiling/spot light/CFL/LED Fittings indoor on the wall /Ceiling/Rafters/Girders using 23/0.0076" twin twisted wires req nos of round blocks and clampsNo119.0119.05.0FalseNoneNoneFalseNoneFalse595.00
4008062155130Nonecode3Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm305.55305.555.0FalseNoneNoneFalseNoneFalse1527.750
4008063155130NoneEle SRSupplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.Each3133.23133.23.0FalseNoneNoneFalseNoneFalse9399.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17263093040000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17263093040000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17263093040000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17263093040000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17263093040000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration certificateTrueTechnical Bid
Annual turnover certificate with valid UDIN No for last 5 years i.e., from 2019-20 to 2023-24 obtained from the Chartered Accountant and supported by the income tax returns filed by the bidder with IT departments.TrueTechnical Bid
To qualify for award of this contract, each tenderer in his name should have in the last five years period i.e., 2019-20, 2020-21, 2021-22 2022-23 & 2023-24 a. achieved in at least two financial years on average annual financial turnover b. achieved in at least one financial years on average annual financial turnover for SC/ST Tenderers of 100 percent of cost of the work.TrueTechnical Bid
Work done certificate for Satisfactorily completed as prime contractor, at least one similar nature of work value not less than 50 percent from Competent Authority not below the rank of Executive Engineer or equivalent b. at least any construction work to an extent of 25 percent of cost of the work for SC/ST Tenderers And also list of such works in FORMAT-2TrueTechnical Bid
Caste certificate and the domicile certificate in the prescribed format Format-D for tenderers claiming reservation for work reserved for SCTrueTechnical Bid
Existing commitments and ongoing works which are yet to be completedTrueTechnical Bid
The works for which tender acceptance letters are received are to be furnished.TrueTechnical Bid
The information of the works for which tenderer has already submitted tender are to be furnished.TrueTechnical Bid
The information on litigation in which the Tenderer is involved are to be furnished.TrueTechnical Bid
Name, address, and telephone, telex, and fax numbers of the tenderers bankers who may provide references if contacted by the employer are not furnished.TrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity A X N X 5 - BTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone