3993772 | 154554 | None | code1 | Construction of Additional Room To
Pre-Metric Boys Hostel @Ravihal Village in Sirguppa Taluka of Ballary Dist. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Coulmn | Cum | 11947.26 | 11947.26 | 4.32 | False | None | None | False | None | False | 51612.1632 | 0 |
3993773 | 154554 | None | code2 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Lintel,Roof Beam | Cum | 11244.48 | 11244.48 | 6.6 | False | None | None | False | None | False | 74213.568 | 0 |
3993774 | 154554 | None | code3 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Chejja and Racks | Cum | 10190.31 | 10190.31 | 0.156 | False | None | None | False | None | False | 1589.68836 | 0 |
3993775 | 154554 | None | code4 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Roof Slab | Cum | 10541.7 | 10541.7 | 15.581 | False | None | None | False | None | False | 164250.2277 | 0 |
3993776 | 154554 | None | code5 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 94824.42 | 94824.42 | 2.019 | False | None | None | False | None | False | 191450.50398 | 0 |
3993777 | 154554 | None | code6 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8447.14 | 8447.14 | 22.52 | False | None | None | False | None | False | 190229.5928 | 0 |
3993778 | 154554 | None | code7 | Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as p | Sqm | 4496.52 | 4496.52 | 10.8 | False | None | None | False | None | False | 48562.416 | 0 |
3993779 | 154554 | None | code8 | Inside Plastering Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 369.68 | 369.68 | 137.82 | False | None | None | False | None | False | 50949.2976 | 0 |
3993780 | 154554 | None | code9 | External plastering Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 441.23 | 441.23 | 122.9 | False | None | None | False | None | False | 54227.167 | 0 |
3993781 | 154554 | None | code10 | Wall Putty Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.98 | 87.98 | 79.67 | False | None | None | False | None | False | 7009.3666 | 0 |
3993782 | 154554 | None | code11 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 134.62 | 134.62 | 340.3 | False | None | None | False | None | False | 45811.186 | 0 |
3993783 | 154554 | None | code12 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete | Sqm | 1146.92 | 1146.92 | 109.25 | False | None | None | False | None | False | 125301.01 | 0 |
3993784 | 154554 | None | code13 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1 9/20 mm dia 2mm thick | m | 66.0 | 66.0 | 60.0 | False | None | None | False | None | False | 3960.0 | 0 |
3993785 | 154554 | None | code14 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | m | 78.0 | 78.0 | 30.0 | False | None | None | False | None | False | 2340.0 | 0 |
3993786 | 154554 | None | code15 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75x75x65mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
3993787 | 154554 | None | code16 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mm | Each | 179.0 | 179.0 | 3.0 | False | None | None | False | None | False | 537.0 | 0 |
3993788 | 154554 | None | code17 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mm | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
3993789 | 154554 | None | code18 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 5.0 | False | None | None | False | None | False | 245.0 | 0 |
3993790 | 154554 | None | code19 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction Box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
3993791 | 154554 | None | code20 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm Conduit in Brick Walls | m | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
3993792 | 154554 | None | code21 | Supplying And Fixing Metal Fan Box with Round Hook | Nos | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 |
3993793 | 154554 | None | code22 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A Short piont up to 3 Mtr from tapping piont out let via switch | Each | 285.0 | 285.0 | 3.0 | False | None | None | False | None | False | 855.0 | 0 |
3993794 | 154554 | None | code23 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 3Mtr to 6 Mtr from tapping piont out let via switch. | Each | 394.0 | 394.0 | 3.0 | False | None | None | False | None | False | 1182.0 | 0 |
3993795 | 154554 | None | code24 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 6Mtr to 10 Mtr from tapping piont out let via switch. | Each | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3993796 | 154554 | None | code25 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.1.5 Sqmm | m | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
3993797 | 154554 | None | code26 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | m | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 |
3993798 | 154554 | None | code27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.4 Sqmm | m | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
3993799 | 154554 | None | code28 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 1 to 3 Module | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 |
3993800 | 154554 | None | code29 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 4 Module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 |
3993801 | 154554 | None | code30 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 8Module | Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 |
3993802 | 154554 | None | code31 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
3993803 | 154554 | None | code32 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16 Amps one way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
3993804 | 154554 | None | code33 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 156.0 | 156.0 | 4.0 | False | None | None | False | None | False | 624.0 | 0 |
3993805 | 154554 | None | code34 | Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
3993806 | 154554 | None | code35 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve, indicator ON/OFF energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
3993807 | 154554 | None | code36 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve, indicator ON/OFF energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
3993808 | 154554 | None | code37 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.8 Way SP & N | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3993809 | 154554 | None | code38 | Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete.250Amps 4x30x10mm Aluminium Strips | m | 3435.0 | 3435.0 | 1.0 | False | None | None | False | None | False | 3435.0 | 0 |
3993810 | 154554 | None | code39 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 690.0 | 690.0 | 3.0 | False | None | None | False | None | False | 2070.0 | 0 |
3993811 | 154554 | None | code40 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 63.0 | 63.0 | 3.0 | False | None | None | False | None | False | 189.0 | 0 |
3993812 | 154554 | None | code41 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 |
3993813 | 154554 | None | code42 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 490.0 | 490.0 | 4.0 | False | None | None | False | None | False | 1960.0 | 0 |
3993814 | 154554 | None | code43 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system. | Nos | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 |
3993815 | 154554 | None | code44 | Fixingaceiling /wallmounting fanof all capacities andall types, withnecessaryclampsand 'S' hookmadeoutof15mmdiaMSrod, with5A. ceiling roseofapproved qualitywithnecessarylengthof 23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality,
mounted on a suitable size wooden board and wired | Each | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 |