1725964580000 | 0 | None | None | Buildings | Providing Chief Minister Gram Vikas Yojan at D.Kaggal Village, Ballari Taluk and Dist. | 1903248.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3951587 | 153041 | None | code01 | Providng CC Road from E. Veeresh house to Manikanta House in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 109.2 | 109.2 | 19.5 | False | None | None | False | None | False | 2129.4 | 0 | 3951588 | 153041 | None | code02 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 19.5 | False | None | None | False | None | False | 9705.15 | 0 | 3951589 | 153041 | None | code03 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. | Cum | 2686.95 | 2686.95 | 16.25 | False | None | None | False | None | False | 43662.9375 | 0 | 3951590 | 153041 | None | code04 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 19.5 | False | None | None | False | None | False | 130507.65 | 0 | 3951591 | 153041 | None | code05 | Providng CC Road from Kade Mane Thimmanna house to Kolur Siddaiah House in D.Kagalla Village: Compacting Original Ground Compating original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 109.2 | 109.2 | 13.088 | False | None | None | False | None | False | 1429.2096 | 0 | 3951592 | 153041 | None | code06 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 13.088 | False | None | None | False | None | False | 6513.8976 | 0 | 3951593 | 153041 | None | code07 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. | Cum | 2686.95 | 2686.95 | 10.906 | False | None | None | False | None | False | 29303.8767 | 0 | 3951594 | 153041 | None | code08 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 13.088 | False | None | None | False | None | False | 87594.0576 | 0 | 3951595 | 153041 | None | code09 | Providng CC Road from Gundethi Pakkira Sab house to P.Maboo Sab House in D.Kagalla Village:Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 109.2 | 109.2 | 18.36 | False | None | None | False | None | False | 2004.912 | 0 | 3951596 | 153041 | None | code10 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 18.36 | False | None | None | False | None | False | 9137.772 | 0 | 3951597 | 153041 | None | code11 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. | Cum | 2686.95 | 2686.95 | 15.3 | False | None | None | False | None | False | 41110.335 | 0 | 3951598 | 153041 | None | code12 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 18.36 | False | None | None | False | None | False | 122877.972 | 0 | 3951599 | 153041 | None | code13 | Providng CC Road from Chatni Durgappa house to Basarkatte Honnurappa House in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 109.2 | 109.2 | 26.625 | False | None | None | False | None | False | 2907.45 | 0 | 3951600 | 153041 | None | code14 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 26.625 | False | None | None | False | None | False | 13251.2625 | 0 | 3951601 | 153041 | None | code15 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. | Cum | 2686.95 | 2686.95 | 22.188 | False | None | None | False | None | False | 59618.0466 | 0 | 3951602 | 153041 | None | code16 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 26.625 | False | None | None | False | None | False | 178193.1375 | 0 | 3951603 | 153041 | None | code17 | Providng CC Road from Mariswamy house to Sree Eranna Temple in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 109.2 | 109.2 | 15.762 | False | None | None | False | None | False | 1721.2104 | 0 | 3951604 | 153041 | None | code18 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 15.762 | False | None | None | False | None | False | 7844.7474 | 0 | 3951605 | 153041 | None | code19 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. | Cum | 2686.95 | 2686.95 | 13.135 | False | None | None | False | None | False | 35293.08825 | 0 | 3951606 | 153041 | None | code20 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 15.762 | False | None | None | False | None | False | 105490.3374 | 0 | 3951607 | 153041 | None | code21 | Construction of Samudhya Bhavan at D. Kaggal village : Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 52.87 | False | None | None | False | None | False | 13434.267 | 0 | 3951608 | 153041 | None | code22 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 7.1 | False | None | None | False | None | False | 44647.995 | 0 | 3951609 | 153041 | None | code23 | Foting : Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7104.31 | 7104.31 | 4.7 | False | None | None | False | None | False | 33390.257 | 0 | 3951610 | 153041 | None | code24 | Columns upto Plinth: Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11088.0 | 11088.0 | 1.69 | False | None | None | False | None | False | 18738.72 | 0 | 3951611 | 153041 | None | code25 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 7.43 | False | None | None | False | None | False | 43774.2165 | 0 | 3951612 | 153041 | None | code26 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 4.27 | False | None | None | False | None | False | 28645.0815 | 0 | 3951613 | 153041 | None | code27 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 41.49 | False | None | None | False | None | False | 11588.157 | 0 | 3951614 | 153041 | None | code28 | Plinth beam: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 2.14 | False | None | None | False | None | False | 22346.415 | 0 | 3951615 | 153041 | None | code29 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 18.0 | False | None | None | False | None | False | 8958.6 | 0 | 3951616 | 153041 | None | code30 | Columns: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11975.25 | 11975.25 | 2.74 | False | None | None | False | None | False | 32812.185 | 0 | 3951617 | 153041 | None | code31 | Lintel: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 0.85 | False | None | None | False | None | False | 9467.64 | 0 | 3951618 | 153041 | None | code32 | Roof slab: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 7.68 | False | None | None | False | None | False | 80196.48 | 0 | 3951619 | 153041 | None | code33 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 2.12 | False | None | None | False | None | False | 199131.282 | 0 | 3951620 | 153041 | None | code34 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 26.0 | False | None | None | False | None | False | 217553.7 | 0 | 3951621 | 153041 | None | code35 | Chejjas: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 0.22 | False | None | None | False | None | False | 2187.9 | 0 | 3951622 | 153041 | None | code36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 124.74 | False | None | None | False | None | False | 22004.136 | 0 | 3951623 | 153041 | None | code37 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6878.55 | 6878.55 | 4.32 | False | None | None | False | None | False | 29715.336 | 0 | 3951624 | 153041 | None | code38 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 2.52 | False | None | None | False | None | False | 11224.332 | 0 | 3951625 | 153041 | None | code39 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 265.65 | 265.65 | 129.54 | False | None | None | False | None | False | 34412.301 | 0 | 3951626 | 153041 | None | code40 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 371.7 | 371.7 | 98.15 | False | None | None | False | None | False | 36482.355 | 0 | 3951627 | 153041 | None | code41 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm | Sqm | 1299.9 | 1299.9 | 34.55 | False | None | None | False | None | False | 44911.545 | 0 | 3951628 | 153041 | None | code42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 88.77 | False | None | None | False | None | False | 9320.85 | 0 | 3951629 | 153041 | None | code43 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 165.9 | 165.9 | 168.04 | False | None | None | False | None | False | 27877.836 | 0 | 3951630 | 153041 | None | code44 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 175.35 | 175.35 | 5.94 | False | None | None | False | None | False | 1041.579 | 0 | 3951631 | 153041 | None | code45 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 20.0 | False | None | None | False | None | False | 1320.0 | 0 | 3951632 | 153041 | None | code46 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 20.0 | False | None | None | False | None | False | 1560.0 | 0 | 3951633 | 153041 | None | code47 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 | 3951634 | 153041 | None | code48 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mm | Each | 118.0 | 118.0 | 1.0 | False | None | None | False | None | False | 118.0 | 0 | 3951635 | 153041 | None | code49 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mm | Each | 348.0 | 348.0 | 1.0 | False | None | None | False | None | False | 348.0 | 0 | 3951636 | 153041 | None | code50 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 1.0 | False | None | None | False | None | False | 49.0 | 0 | 3951637 | 153041 | None | code51 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 | 3951638 | 153041 | None | code52 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | m | 29.0 | 29.0 | 8.0 | False | None | None | False | None | False | 232.0 | 0 | 3951639 | 153041 | None | code53 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod. | No | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 | 3951640 | 153041 | None | code54 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod. | No | 85.0 | 85.0 | 2.0 | False | None | None | False | None | False | 170.0 | 0 | 3951641 | 153041 | None | code55 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 3951642 | 153041 | None | code56 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | 3951643 | 153041 | None | code57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 sqmm | m | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 | 3951644 | 153041 | None | code58 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmm | m | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | 3951645 | 153041 | None | code59 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 | 3951646 | 153041 | None | code60 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 | 3951647 | 153041 | None | code61 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 284.0 | 284.0 | 1.0 | False | None | None | False | None | False | 284.0 | 0 | 3951648 | 153041 | None | code62 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 4.0 | False | None | None | False | None | False | 408.0 | 0 | 3951649 | 153041 | None | code63 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | 3951650 | 153041 | None | code64 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push | Each | 180.0 | 180.0 | 2.0 | False | None | None | False | None | False | 360.0 | 0 | 3951651 | 153041 | None | code65 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3951652 | 153041 | None | code66 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 | 3951653 | 153041 | None | code67 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 | 3951654 | 153041 | None | code68 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N | Each | 1695.0 | 1695.0 | 1.0 | False | None | None | False | None | False | 1695.0 | 0 | 3951655 | 153041 | None | code69 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause
7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 | 3951656 | 153041 | None | code70 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part- 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 | m | 180.0 | 180.0 | 20.0 | False | None | None | False | None | False | 3600.0 | 0 | 3951657 | 153041 | None | code71 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 3951658 | 153041 | None | code72 | Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 2.0 | False | None | None | False | None | False | 1380.0 | 0 | 3951659 | 153041 | None | code73 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | No | 118.0 | 118.0 | 2.0 | False | None | None | False | None | False | 236.0 | 0 | 3951660 | 153041 | None | code74 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 490.0 | 490.0 | 2.0 | False | None | None | False | None | False | 980.0 | 0 | 3951661 | 153041 | None | code75 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 |
|