createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725964580178
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd45500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-09-2024 16:30:00
tenderQueryClose24-09-2024 15:30:00
technicalBidOpenNone
publishedDate17-09-2024 10:14:42
publishedByPostRDPR_EE_DIV_BLR
publishedByUserKPE19203 - H INDUDHAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRE DIVISION BALLARI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08392266173
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1725964580218
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8742
titleConstruction of CC Road in Various Colonies and Samudaya Bhavan in D Kaggal under Chief Miniter grama vikas yojana works of Ballari Taluk and Dist
descriptionConstruction of CC Road in Various Colonies and Samudaya Bhavan in D Kaggal under Chief Miniter grama vikas yojana works of Ballari Taluk and Dist
categoryWORKS
categoryTextWorks
ecv1903248.66
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location818
locationNameRDPR Division Office Ballari
provisionalAmount2256000.0
groupOverheadTotalNone
fileNumberAEE/RDPR/SD/BLR/JE-1/GVY/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17259645800000NoneNoneBuildingsProviding Chief Minister Gram Vikas Yojan at D.Kaggal Village, Ballari Taluk and Dist.1903248.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3951587153041Nonecode01Providng CC Road from E. Veeresh house to Manikanta House in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum109.2109.219.5FalseNoneNoneFalseNoneFalse2129.40
3951588153041Nonecode02Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.719.5FalseNoneNoneFalseNoneFalse9705.150
3951589153041Nonecode03Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity.Cum2686.952686.9516.25FalseNoneNoneFalseNoneFalse43662.93750
3951590153041Nonecode04Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6692.76692.719.5FalseNoneNoneFalseNoneFalse130507.650
3951591153041Nonecode05Providng CC Road from Kade Mane Thimmanna house to Kolur Siddaiah House in D.Kagalla Village: Compacting Original Ground Compating original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum109.2109.213.088FalseNoneNoneFalseNoneFalse1429.20960
3951592153041Nonecode06Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.713.088FalseNoneNoneFalseNoneFalse6513.89760
3951593153041Nonecode07Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity.Cum2686.952686.9510.906FalseNoneNoneFalseNoneFalse29303.87670
3951594153041Nonecode08Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6692.76692.713.088FalseNoneNoneFalseNoneFalse87594.05760
3951595153041Nonecode09Providng CC Road from Gundethi Pakkira Sab house to P.Maboo Sab House in D.Kagalla Village:Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum109.2109.218.36FalseNoneNoneFalseNoneFalse2004.9120
3951596153041Nonecode10Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.718.36FalseNoneNoneFalseNoneFalse9137.7720
3951597153041Nonecode11Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity.Cum2686.952686.9515.3FalseNoneNoneFalseNoneFalse41110.3350
3951598153041Nonecode12Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6692.76692.718.36FalseNoneNoneFalseNoneFalse122877.9720
3951599153041Nonecode13Providng CC Road from Chatni Durgappa house to Basarkatte Honnurappa House in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum109.2109.226.625FalseNoneNoneFalseNoneFalse2907.450
3951600153041Nonecode14Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.726.625FalseNoneNoneFalseNoneFalse13251.26250
3951601153041Nonecode15Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity.Cum2686.952686.9522.188FalseNoneNoneFalseNoneFalse59618.04660
3951602153041Nonecode16Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6692.76692.726.625FalseNoneNoneFalseNoneFalse178193.13750
3951603153041Nonecode17Providng CC Road from Mariswamy house to Sree Eranna Temple in D.Kagalla Village: Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum109.2109.215.762FalseNoneNoneFalseNoneFalse1721.21040
3951604153041Nonecode18Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.715.762FalseNoneNoneFalseNoneFalse7844.74740
3951605153041Nonecode19Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity.Cum2686.952686.9513.135FalseNoneNoneFalseNoneFalse35293.088250
3951606153041Nonecode20Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6692.76692.715.762FalseNoneNoneFalseNoneFalse105490.33740
3951607153041Nonecode21Construction of Samudhya Bhavan at D. Kaggal village : Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.152.87FalseNoneNoneFalseNoneFalse13434.2670
3951608153041Nonecode22Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.457.1FalseNoneNoneFalseNoneFalse44647.9950
3951609153041Nonecode23Foting : Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7104.317104.314.7FalseNoneNoneFalseNoneFalse33390.2570
3951610153041Nonecode24Columns upto Plinth: Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11088.011088.01.69FalseNoneNoneFalseNoneFalse18738.720
3951611153041Nonecode25Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.557.43FalseNoneNoneFalseNoneFalse43774.21650
3951612153041Nonecode26Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.454.27FalseNoneNoneFalseNoneFalse28645.08150
3951613153041Nonecode27Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.341.49FalseNoneNoneFalseNoneFalse11588.1570
3951614153041Nonecode28Plinth beam: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.252.14FalseNoneNoneFalseNoneFalse22346.4150
3951615153041Nonecode29Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum497.7497.718.0FalseNoneNoneFalseNoneFalse8958.60
3951616153041Nonecode30Columns: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11975.2511975.252.74FalseNoneNoneFalseNoneFalse32812.1850
3951617153041Nonecode31Lintel: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.85FalseNoneNoneFalseNoneFalse9467.640
3951618153041Nonecode32Roof slab: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.257.68FalseNoneNoneFalseNoneFalse80196.480
3951619153041Nonecode33Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne93929.8593929.852.12FalseNoneNoneFalseNoneFalse199131.2820
3951620153041Nonecode34Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.4526.0FalseNoneNoneFalseNoneFalse217553.70
3951621153041Nonecode35Chejjas: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9945.09945.00.22FalseNoneNoneFalseNoneFalse2187.90
3951622153041Nonecode36Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4124.74FalseNoneNoneFalseNoneFalse22004.1360
3951623153041Nonecode37Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6878.556878.554.32FalseNoneNoneFalseNoneFalse29715.3360
3951624153041Nonecode38Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4454.14454.12.52FalseNoneNoneFalseNoneFalse11224.3320
3951625153041Nonecode39Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm265.65265.65129.54FalseNoneNoneFalseNoneFalse34412.3010
3951626153041Nonecode40Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.Sqm371.7371.798.15FalseNoneNoneFalseNoneFalse36482.3550
3951627153041Nonecode41Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mmSqm1299.91299.934.55FalseNoneNoneFalseNoneFalse44911.5450
3951628153041Nonecode42Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.088.77FalseNoneNoneFalseNoneFalse9320.850
3951629153041Nonecode43Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.9168.04FalseNoneNoneFalseNoneFalse27877.8360
3951630153041Nonecode44Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm175.35175.355.94FalseNoneNoneFalseNoneFalse1041.5790
3951631153041Nonecode45Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickm66.066.020.0FalseNoneNoneFalseNoneFalse1320.00
3951632153041Nonecode46Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickm78.078.020.0FalseNoneNoneFalseNoneFalse1560.00
3951633153041Nonecode47Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mmEach106.0106.01.0FalseNoneNoneFalseNoneFalse106.00
3951634153041Nonecode48Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mmEach118.0118.01.0FalseNoneNoneFalseNoneFalse118.00
3951635153041Nonecode49Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mmEach348.0348.01.0FalseNoneNoneFalseNoneFalse348.00
3951636153041Nonecode50Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxEach49.049.01.0FalseNoneNoneFalseNoneFalse49.00
3951637153041Nonecode51Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach56.056.01.0FalseNoneNoneFalseNoneFalse56.00
3951638153041Nonecode52Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallm29.029.08.0FalseNoneNoneFalseNoneFalse232.00
3951639153041Nonecode53Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod.No160.0160.02.0FalseNoneNoneFalseNoneFalse320.00
3951640153041Nonecode54Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod.No85.085.02.0FalseNoneNoneFalseNoneFalse170.00
3951641153041Nonecode55Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint285.0285.01.0FalseNoneNoneFalseNoneFalse285.00
3951642153041Nonecode56Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint394.0394.01.0FalseNoneNoneFalseNoneFalse394.00
3951643153041Nonecode57Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 sqmmm26.026.050.0FalseNoneNoneFalseNoneFalse1300.00
3951644153041Nonecode58Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmmm42.042.030.0FalseNoneNoneFalseNoneFalse1260.00
3951645153041Nonecode59Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3951646153041Nonecode60Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 ModuleEach175.0175.01.0FalseNoneNoneFalseNoneFalse175.00
3951647153041Nonecode61Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3951648153041Nonecode62Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.04.0FalseNoneNoneFalseNoneFalse408.00
3951649153041Nonecode63Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach357.0357.02.0FalseNoneNoneFalseNoneFalse714.00
3951650153041Nonecode64Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell PushEach180.0180.02.0FalseNoneNoneFalseNoneFalse360.00
3951651153041Nonecode65Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone SocketEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3951652153041Nonecode66Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach523.0523.01.0FalseNoneNoneFalseNoneFalse523.00
3951653153041Nonecode67Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach523.0523.01.0FalseNoneNoneFalseNoneFalse523.00
3951654153041Nonecode68Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & NEach1695.01695.01.0FalseNoneNoneFalseNoneFalse1695.00
3951655153041Nonecode69Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3750.03750.01.0FalseNoneNoneFalseNoneFalse3750.00
3951656153041Nonecode70Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part- 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975m180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3951657153041Nonecode71Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modelEach2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
3951658153041Nonecode72Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach690.0690.02.0FalseNoneNoneFalseNoneFalse1380.00
3951659153041Nonecode73Supplying & Fixing of 70-150 W lamp holder 2 PinNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3951660153041Nonecode74Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / GirdersEach490.0490.02.0FalseNoneNoneFalseNoneFalse980.00
3951661153041Nonecode75Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17259645830000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17259645830000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17259645830000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17259645830000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17259645830000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17259645830000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17259645830000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17259645830000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17259645830000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17259645830000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration certificateTrueTechnical Bid
Annual turnover certificate with valid UDIN No for last 5 years i.e., from 2019-20 to 2023-24 obtained from the Chartered Accountant and supported by the income tax returns filed by the bidder with IT departments.TrueTechnical Bid
To qualify for award of this contract, each tenderer in his name should have in the last five years period i.e. 2019-20 2020-21 2021-22 2022-23 2023-24 achieved in at least two financial years on average annual financial turnover of 100 percent of cost of the work.TrueTechnical Bid
Work done certificate for Satisfactorily completed as prime contractor, at least one similar nature of work value not less than 50 percent from Competent Authority not below the rank of Executive Engineer or equivalent And also list of such works in FORMAT-2TrueTechnical Bid
Existing commitments and ongoing works which are yet to be completedTrueTechnical Bid
The works for which tender acceptance letters are received are to be furnished.TrueTechnical Bid
The information of the works for which tenderer has already submitted tender are to be furnished.TrueTechnical Bid
The information on litigation in which the Tenderer is involved are to be furnished.TrueTechnical Bid
Name, address, and telephone, telex, and fax numbers of the tenderers bankers who may provide references if contacted by the employer are not furnished.TrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity A X N X 2.5 - BTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone