4013327 | 155436 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 242.0 | 242.0 | 5.0 | False | None | None | False | None | False | 1210.0 | 0 |
4013328 | 155436 | None | code02 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 554.0 | 554.0 | 14.445 | False | None | None | False | None | False | 8002.53 | 0 |
4013329 | 155436 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 2.461 | False | None | None | False | None | False | 13939.104 | 0 |
4013330 | 155436 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5611.0 | 5611.0 | 5.707 | False | None | None | False | None | False | 32021.977 | 0 |
4013331 | 155436 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6389.0 | 6389.0 | 6.487 | False | None | None | False | None | False | 41445.443 | 0 |
4013332 | 155436 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 266.0 | 266.0 | 13.65 | False | None | None | False | None | False | 3630.9 | 0 |
4013333 | 155436 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 2.685 | False | None | None | False | None | False | 16692.645 | 0 |
4013334 | 155436 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8211.0 | 8211.0 | 15.998 | False | None | None | False | None | False | 131359.578 | 0 |
4013335 | 155436 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7956.0 | 7956.0 | 2.764 | False | None | None | False | None | False | 21990.384 | 0 |
4013336 | 155436 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for Buildings | Tonne | 89457.0 | 89457.0 | 0.157 | False | None | None | False | None | False | 14044.749 | 0 |
4013337 | 155436 | None | code11 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance1mm), with wall thickness 2.0 mm 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- incharge 48x40 mm PVC Extruded section | Sqm | 198.0 | 198.0 | 8.25 | False | None | None | False | None | False | 1633.5 | 0 |
4013338 | 155436 | None | code12 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam | Sqm | 2366.0 | 2366.0 | 4.5 | False | None | None | False | None | False | 10647.0 | 0 |
4013339 | 155436 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc | Cum | 183.0 | 183.0 | 53.393 | False | None | None | False | None | False | 9770.919 | 0 |
4013340 | 155436 | None | code14 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 255.0 | 255.0 | 7.358 | False | None | None | False | None | False | 1876.29 | 0 |
4013341 | 155436 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 295.0 | 295.0 | 59.268 | False | None | None | False | None | False | 17484.06 | 0 |
4013342 | 155436 | None | code16 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 333.0 | 333.0 | 12.24 | False | None | None | False | None | False | 4075.92 | 0 |
4013343 | 155436 | None | code17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm | Sqm | 1145.0 | 1145.0 | 8.117 | False | None | None | False | None | False | 9293.965 | 0 |
4013344 | 155436 | None | code18 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1392.0 | 1392.0 | 15.12 | False | None | None | False | None | False | 21047.04 | 0 |
4013345 | 155436 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 137.0 | 137.0 | 66.625 | False | None | None | False | None | False | 9127.625 | 0 |
4013346 | 155436 | None | code20 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge | Sqm | 255.0 | 255.0 | 12.77 | False | None | None | False | None | False | 3256.35 | 0 |
4013347 | 155436 | None | code21 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Long pattern W.C. pan of size 580 mm | Each | 1428.0 | 1428.0 | 3.0 | False | None | None | False | None | False | 4284.0 | 0 |
4013348 | 155436 | None | code22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | Each | 2099.0 | 2099.0 | 1.0 | False | None | None | False | None | False | 2099.0 | 0 |
4013349 | 155436 | None | code23 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore | Each | 286.0 | 286.0 | 4.0 | False | None | None | False | None | False | 1144.0 | 0 |
4013350 | 155436 | None | code24 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) Pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (external work) | Mtr | 179.0 | 179.0 | 10.0 | False | None | None | False | None | False | 1790.0 | 0 |
4013351 | 155436 | None | code25 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) Pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) | Mtr | 157.0 | 157.0 | 8.0 | False | None | None | False | None | False | 1256.0 | 0 |
4013352 | 155436 | None | code26 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressures with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and testing complete as per specifications. | Mtr | 434.0 | 434.0 | 6.0 | False | None | None | False | None | False | 2604.0 | 0 |
4013353 | 155436 | None | code27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.0 | 9.0 | 1000.0 | False | None | None | False | None | False | 9000.0 | 0 |
4013354 | 155436 | None | code28 | KSRB 12-8.1 : Constructing brick masonry inspection chamber 450x300mm and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I. cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and down size granite metal, foundtion concrete 1:5:10 with 40mm and down size granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. | Each | 3800.0 | 3800.0 | 1.0 | False | None | None | False | None | False | 3800.0 | 0 |
4013355 | 155436 | None | code29 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1)a) Short point upto 3Mtr from tapping point to out let via switch (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1.1) | Point | 200.0 | 200.0 | 6.0 | False | None | None | False | None | False | 1200.0 | 0 |
4013356 | 155436 | None | code30 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1)b) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1.2) | Point | 275.0 | 275.0 | 8.0 | False | None | None | False | None | False | 2200.0 | 0 |
4013357 | 155436 | None | code31 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1)c) Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch (PWD Electrical DSR 2019-20 / P.No.5, I.No.2.1.3) | Point | 400.0 | 400.0 | 8.0 | False | None | None | False | None | False | 3200.0 | 0 |
4013358 | 155436 | None | code32 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket (PWD Electrical DSR 2019-20 / P.No.10/I.No.3.6.11) | Nos | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 |
4013359 | 155436 | None | code33 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps lamp holder (PWD Electrical DSR 2019-20 / P.No.11/I.No.3.14.6) | Nos | 58.0 | 58.0 | 22.0 | False | None | None | False | None | False | 1276.0 | 0 |
4013360 | 155436 | None | code34 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (PWD Electrical DSR 2019-20 / P.No.10/I.No.3.6.8) | Nos | 115.0 | 115.0 | 24.0 | False | None | None | False | None | False | 2760.0 | 0 |
4013361 | 155436 | None | code35 | Supplying and fixing PVC/metal conduit Deep junction box a) 19/20mm deep junction box
(PWD Electrical DSR 2019-20 / P.No.3/I.No.1.5.1) | Nos | 43.0 | 43.0 | 8.0 | False | None | None | False | None | False | 344.0 | 0 |
4013362 | 155436 | None | code36 | Supplying and fixing PVC/metal conduit Deep junction box b) 25mm deep junction Box
(PWD Electrical DSR 2019-20 / P.No.3/I.No.1.5.2) | Nos | 47.0 | 47.0 | 10.0 | False | None | None | False | None | False | 470.0 | 0 |
4013363 | 155436 | None | code37 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screwsa) 80 mm (PWD Electrical DSR 2019-20 / P.No.10 / I.No.3.10.1) | Nos | 9.0 | 9.0 | 8.0 | False | None | None | False | None | False | 72.0 | 0 |
4013364 | 155436 | None | code38 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws b) 110mm (PWD Electrical DSR 2019-20 / P.No.10/I.No.3.10.2) | Nos | 11.0 | 11.0 | 10.0 | False | None | None | False | None | False | 110.0 | 0 |
4013365 | 155436 | None | code39 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall (PWD Electrical DSR 2019-20 / P.No.3/I.No.1.7.1) | Mtr | 21.0 | 21.0 | 145.0 | False | None | None | False | None | False | 3045.0 | 0 |
4013366 | 155436 | None | code40 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4) a) 4-5 Way
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4.2) | Nos | 105.0 | 105.0 | 1.0 | False | None | None | False | None | False | 105.0 | 0 |
4013367 | 155436 | None | code41 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4) b) 6 Way
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4.3) | Nos | 125.0 | 125.0 | 1.0 | False | None | None | False | None | False | 125.0 | 0 |
4013368 | 155436 | None | code42 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4) c) 8 Way
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4.4) | Nos | 145.0 | 145.0 | 2.0 | False | None | None | False | None | False | 290.0 | 0 |
4013369 | 155436 | None | code43 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4) d) 10-12 Way
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.4.5) | Nos | 165.0 | 165.0 | 1.0 | False | None | None | False | None | False | 165.0 | 0 |
4013370 | 155436 | None | code44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5) a) 4 Module
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5.2) | Nos | 125.0 | 125.0 | 1.0 | False | None | None | False | None | False | 125.0 | 0 |
4013371 | 155436 | None | code45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5) b) 6 Module
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5.3) | Nos | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 |
4013372 | 155436 | None | code46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5) c) 8 Module
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5.4) | Nos | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 |
4013373 | 155436 | None | code47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5) d) 10-12 Module
(PWD Electrical DSR 2019-20 / P.No.9/I.No.3.5.5) | Nos | 230.0 | 230.0 | 1.0 | False | None | None | False | None | False | 230.0 | 0 |
4013374 | 155436 | None | code48 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD Electrical DSR 2019-20 / P.No.27/I.No.5.17)a) 6-32 Amps SP
(PWD Electrical DSR 2019-20 / P.No.27 / I.No.5.17.1) | Nos | 434.0 | 434.0 | 2.0 | False | None | None | False | None | False | 868.0 | 0 |
4013375 | 155436 | None | code49 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD Electrical DSR 2019-20 / P.No.27/I.No.5.17)b) 40 Amps SP
(PWD Electrical DSR 2019-20 / P.No.27 / I.No.5.17.2) | Nos | 713.0 | 713.0 | 1.0 | False | None | None | False | None | False | 713.0 | 0 |
4013376 | 155436 | None | code50 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD Electrical DSR 2019-20 / P.No.27/I.No.5.17)c) 6-32 Amps DP
(PWD Electrical DSR 2019-20 / P.No.27 / I.No.5.17.4) | Nos | 909.0 | 909.0 | 1.0 | False | None | None | False | None | False | 909.0 | 0 |
4013377 | 155436 | None | code51 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door. 12Way SP &N (PWD Electrical DSR 2019-20 / P.No.47/I.No.6.17.5) | Nos | 1800.0 | 1800.0 | 1.0 | False | None | None | False | None | False | 1800.0 | 0 |
4013378 | 155436 | None | code52 | Supplying & fixing flexible LED Strip LightW Power consumption in 5mtrs length CCT 6500 degree K, CRI70 efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition (PWD Electrical DSR 2019-20 / P.No.64/I.No.12.1) | Nos | 1400.0 | 1400.0 | 4.0 | False | None | None | False | None | False | 5600.0 | 0 |
4013379 | 155436 | None | code53 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires (PWD Electrical DSR 2019-20 / P.No.79/I.No.14.5) | Nos | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 |
4013380 | 155436 | None | code54 | Supplying & fixing retrofit type PL LED Lamp W LED linear source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8-9 Watts (PWD Electrical DSR 2019-20 / P.No.64/I.No.12.2.1) | Nos | 350.0 | 350.0 | 2.0 | False | None | None | False | None | False | 700.0 | 0 |
4013381 | 155436 | None | code55 | Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick (PWD Electrical DSR 2019-20 / P.No.2/I.No.1.1.1) | Mtr | 50.0 | 50.0 | 50.0 | False | None | None | False | None | False | 2500.0 | 0 |
4013382 | 155436 | None | code56 | Supplying heavy gauge PVC conduit pipe.dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an intervab) 25mm dia 2mm thick (PWD Electrical DSR 2019-20 / P.No.2/I.No.1.1.2) | Mtr | 65.0 | 65.0 | 30.0 | False | None | None | False | None | False | 1950.0 | 0 |
4013383 | 155436 | None | code57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (PWD Electrical DSR 2019-20 / P.No.6/I.No.2.3.3) | Mtr | 32.0 | 32.0 | 90.0 | False | None | None | False | None | False | 2880.0 | 0 |
4013384 | 155436 | None | code58 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest d) 4 sqmm (PWD Electrical DSR 2019-20 / P.No.6 / I.No.2.3.4) | Mtr | 45.0 | 45.0 | 20.0 | False | None | None | False | None | False | 900.0 | 0 |
4013385 | 155436 | None | code59 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 2 core 16 sqmm. (PWD Electrical DSR 2019-20 / P.No.40/I.No.6.4.3) | Mtr | 120.0 | 120.0 | 12.0 | False | None | None | False | None | False | 1440.0 | 0 |
4013386 | 155436 | None | code60 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct. 6 sqmm to 16 sqmm (PWD Electrical DSR 2019-20 / P.No.41/I.No.6.5.1) | Mtr | 11.88 | 11.88 | 12.0 | False | None | None | False | None | False | 142.56 | 0 |