4007380 | 155123 | None | code1 | CONSTRUCTION OF LIBRARY BUILDING @ Byrapura VILLAGE IN SIRUGUPPA TALUK. Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 45.0 | False | None | None | False | None | False | 4488.75 | 0 |
4007381 | 155123 | None | code2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 51.23 | False | None | None | False | None | False | 13017.543 | 0 |
4007382 | 155123 | None | code3 | Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6288.45 | 6288.45 | 9.91 | False | None | None | False | None | False | 62318.5395 | 0 |
4007383 | 155123 | None | code4 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) footing | Cum | 6971.11 | 6971.11 | 7.13 | False | None | None | False | None | False | 49704.0143 | 0 |
4007384 | 155123 | None | code5 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) colum | Cum | 11286.55 | 11286.55 | 1.53 | False | None | None | False | None | False | 17268.4215 | 0 |
4007385 | 155123 | None | code6 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Coulmn | Cum | 11834.55 | 11834.55 | 3.93 | False | None | None | False | None | False | 46509.7815 | 0 |
4007386 | 155123 | None | code7 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Ground Beam ,Plinth Beam | Cum | 10442.25 | 10442.25 | 7.14 | False | None | None | False | None | False | 74557.665 | 0 |
4007387 | 155123 | None | code8 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Lintel,Roof Beam | Cum | 11138.4 | 11138.4 | 6.65 | False | None | None | False | None | False | 74070.36 | 0 |
4007388 | 155123 | None | code9 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Chejja and Racks | Cum | 10094.18 | 10094.18 | 0.519 | False | None | None | False | None | False | 5238.87942 | 0 |
4007389 | 155123 | None | code10 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Roof Slab | Cum | 10442.25 | 10442.25 | 11.37 | False | None | None | False | None | False | 118728.3825 | 0 |
4007390 | 155123 | None | code11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 93929.85 | 93929.85 | 2.95 | False | None | None | False | None | False | 277093.0575 | 0 |
4007391 | 155123 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8376.9 | 8376.9 | 7.33 | False | None | None | False | None | False | 61402.677 | 0 |
4007392 | 155123 | None | code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1375.5 | 1375.5 | 98.28 | False | None | None | False | None | False | 135184.14 | 0 |
4007393 | 155123 | None | code14 | Half brick masonry with Non Modular fly ash bricks of class designation 5.0, conforming to IS :12894, in super structure above plinth and upto floor I level cement mortar 1 : 4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Paraphet wall | Sqm | 1009.0 | 1009.0 | 20.304 | False | None | None | False | None | False | 20486.736 | 0 |
4007394 | 155123 | None | code15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 39.73 | False | None | None | False | None | False | 11096.589 | 0 |
4007395 | 155123 | None | code16 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 65.07 | False | None | None | False | None | False | 32385.339 | 0 |
4007396 | 155123 | None | code17 | Providing and fixing in position collapsible steel shutters with
vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8689.8 | 8689.8 | 3.78 | False | None | None | False | None | False | 32847.444 | 0 |
4007397 | 155123 | None | code18 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 144977.7 | 144977.7 | 0.105 | False | None | None | False | None | False | 15222.6585 | 0 |
4007398 | 155123 | None | code19 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications | Sqm | 7816.2 | 7816.2 | 3.78 | False | None | None | False | None | False | 29545.236 | 0 |
4007399 | 155123 | None | code20 | roviding and fixing factory made single extruded WPC (Wood Polymer
Composite) solid door/window/Clerestory windows & other Frames/
Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibres (wood powder/rice husk/
wheat husk) and non toxic additives (maximum toxicity index of 12 for
100 g) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum
frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &
1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of
elasticity 900 N/mm2 and resistance to spread of flame of Class A category
with property of being termite/borer proof, water/moisture proof and fire
retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners
of required dia and length complete as per direction of Engineer-InCharge.
(Fixtures shall be paid for separately) | m | 250.95 | 250.95 | 17.4 | False | None | None | False | None | False | 4366.53 | 0 |
4007400 | 155123 | None | code21 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification 30 mm thick both side commercial | Sqm | 3005.0 | 3005.0 | 1.89 | False | None | None | False | None | False | 5679.45 | 0 |
4007401 | 155123 | None | code22 | Soild panel PVC Door Shutter Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1667.4 | 1667.4 | 3.15 | False | None | None | False | None | False | 5252.31 | 0 |
4007402 | 155123 | None | code23 | Providing & fixing UPVC windowProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system wiWall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeth touch lock. | Sqm | 5659.5 | 5659.5 | 11.25 | False | None | None | False | None | False | 63669.375 | 0 |
4007403 | 155123 | None | code24 | Providing & fixing Z-Ventilators Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6004.95 | 6004.95 | 2.7 | False | None | None | False | None | False | 16213.365 | 0 |
4007404 | 155123 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding14.3 | Kgs | 176.4 | 176.4 | 309.96 | False | None | None | False | None | False | 54676.944 | 0 |
4007405 | 155123 | None | code26 | Inside Plastering Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 292.95 | 292.95 | 172.52 | False | None | None | False | None | False | 50539.734 | 0 |
4007406 | 155123 | None | code27 | External plastering Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 163.13 | False | None | None | False | None | False | 57038.4045 | 0 |
4007407 | 155123 | None | code28 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 63.17 | False | None | None | False | None | False | 13995.3135 | 0 |
4007408 | 155123 | None | code29 | Wall Putty Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 235.69 | False | None | None | False | None | False | 24747.45 | 0 |
4007409 | 155123 | None | code30 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 398.82 | False | None | None | False | None | False | 53182.647 | 0 |
4007410 | 155123 | None | code31 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge | Sqm | 1233.75 | 1233.75 | 55.31 | False | None | None | False | None | False | 68238.7125 | 0 |
4007411 | 155123 | None | code32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 5.4 | False | None | None | False | None | False | 5040.63 | 0 |
4007412 | 155123 | None | code33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 100 mm diameter | m | 305.55 | 305.55 | 16.0 | False | None | None | False | None | False | 4888.8 | 0 |
4007413 | 155123 | None | code34 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 4.2 | 4.2 | 1000.0 | False | None | None | False | None | False | 4200.0 | 0 |
4007414 | 155123 | None | code35 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 11.92 | False | None | None | False | None | False | 3028.872 | 0 |
4007415 | 155123 | None | code36 | Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6288.45 | 6288.45 | 0.34 | False | None | None | False | None | False | 2138.073 | 0 |
4007416 | 155123 | None | code37 | RCC hume pipe Circular Cistern: Supplying precast RCC Circular Hume pipe Cistern with M.S Gate and RCC roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm | Nos | 17221.05 | 17221.05 | 1.0 | False | None | None | False | None | False | 17221.05 | 0 |
4007417 | 155123 | None | code38 | Erection and positioning of RCC Hume pipe pump house/Cistern
on size stone masory platform including transportation charges and
handling,finishing with all necessary tools ,plants and materials
etc.,complete as directed by the Engineer in charge of the work. | Nos | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 |
4007418 | 155123 | None | code39 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) | Cum | 8353.8 | 8353.8 | 0.58 | False | None | None | False | None | False | 4845.204 | 0 |
4007419 | 155123 | None | code40 | Supplying and delivery 1 mono block pump of 1000mm dia with specified duty conditions as detailed below and satisfying performance characterstics 1HP, 10 stage. H-46 M, Disch-50 LPM. GLB/SR/2019-20/iteam no12.01.3 Rate RS 13780.00/Each | Nos | 14997.15 | 14997.15 | 1.0 | False | None | None | False | None | False | 14997.15 | 0 |
4007420 | 155123 | None | code41 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | l | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
4007421 | 155123 | None | code42 | PVC pipes 32mm dia., 10 kg/sqcm & class 5 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing andcommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for9 | m | 67.67 | 67.67 | 50.0 | False | None | None | False | None | False | 3383.5 | 0 |
4007422 | 155123 | None | code43 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore | Nos | 308.05 | 308.05 | 4.0 | False | None | None | False | None | False | 1232.2 | 0 |
4007423 | 155123 | None | code44 | 90mm(weight of pipe -0.917 kg) Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. | m | 212.1 | 212.1 | 18.0 | False | None | None | False | None | False | 3817.8 | 0 |
4007424 | 155123 | None | code45 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 3584.49 | 3584.49 | 1.0 | False | None | None | False | None | False | 3584.49 | 0 |
4007425 | 155123 | None | code46 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Nos | 4932.84 | 4932.84 | 1.0 | False | None | None | False | None | False | 4932.84 | 0 |
4007426 | 155123 | None | code47 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 2586.61 | 2586.61 | 1.0 | False | None | None | False | None | False | 2586.61 | 0 |
4007427 | 155123 | None | code48 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required | Each | 4883.35 | 4883.35 | 1.0 | False | None | None | False | None | False | 4883.35 | 0 |
4007428 | 155123 | None | code49 | Supplying to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm | Each | 9818.55 | 9818.55 | 2.0 | False | None | None | False | None | False | 19637.1 | 0 |
4007429 | 155123 | None | code50 | Supply & fixing RCC Pre-cast Cover Slab of size 0.8 m x 0.8 m x 0.15m of M25-Design mix concrete with 12 mm steel @ 120 mm c/c both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts. | Each | 2824.5 | 2824.5 | 2.0 | False | None | None | False | None | False | 5649.0 | 0 |
4007430 | 155123 | None | code51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -20mm dia | m | 254.1 | 254.1 | 20.0 | False | None | None | False | None | False | 5082.0 | 0 |
4007431 | 155123 | None | code52 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1 9/20 mm dia 2mm thick | m | 66.0 | 66.0 | 100.0 | False | None | None | False | None | False | 6600.0 | 0 |
4007432 | 155123 | None | code53 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | m | 78.0 | 78.0 | 20.0 | False | None | None | False | None | False | 1560.0 | 0 |
4007433 | 155123 | None | code54 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75x75x65mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
4007434 | 155123 | None | code55 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100x75x75mm | Each | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 |
4007435 | 155123 | None | code56 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mm | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 |
4007436 | 155123 | None | code57 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
4007437 | 155123 | None | code58 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction Box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
4007438 | 155123 | None | code59 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm Conduit in Brick Walls | m | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
4007439 | 155123 | None | code60 | Supplying And Fixing Metal Fan Box with Round Hook | Nos | 117.0 | 117.0 | 4.0 | False | None | None | False | None | False | 468.0 | 0 |
4007440 | 155123 | None | code61 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A Short piont up to 3 Mtr from tapping piont out let via switch | Each | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 |
4007441 | 155123 | None | code62 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 3Mtr to 6 Mtr from tapping piont out let via switch. | Each | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 |
4007442 | 155123 | None | code63 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.1.5 Sqmm | m | 26.0 | 26.0 | 80.0 | False | None | None | False | None | False | 2080.0 | 0 |
4007443 | 155123 | None | code64 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | m | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 |
4007444 | 155123 | None | code65 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 1 to 3 Module | Each | 137.0 | 137.0 | 6.0 | False | None | None | False | None | False | 822.0 | 0 |
4007445 | 155123 | None | code66 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 4 Module | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 |
4007446 | 155123 | None | code67 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 8Module | Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 |
4007447 | 155123 | None | code68 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 102.0 | 102.0 | 8.0 | False | None | None | False | None | False | 816.0 | 0 |
4007448 | 155123 | None | code69 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 |
4007449 | 155123 | None | code70 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16 Amps one way | Each | 180.0 | 180.0 | 6.0 | False | None | None | False | None | False | 1080.0 | 0 |
4007450 | 155123 | None | code71 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 |
4007451 | 155123 | None | code72 | Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
4007452 | 155123 | None | code73 | Supplying &fixing of procelain fuse channel with cut out on existing wodden/panel using necessary nuts,bolts and washwer 32Amps | Each | 241.0 | 241.0 | 1.0 | False | None | None | False | None | False | 241.0 | 0 |
4007453 | 155123 | None | code74 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve, indicator ON/OFF energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
4007454 | 155123 | None | code75 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.8 Way SP & N | Each | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 |
4007455 | 155123 | None | code76 | Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete.250Amps 4x30x10mm Aluminium Strips | m | 3435.0 | 3435.0 | 0.5 | False | None | None | False | None | False | 1717.5 | 0 |
4007456 | 155123 | None | code77 | supplying ,fixing wiring earth for grounding conduits I.C cutouts and other equibments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5m long buried ina a pit the pit should be filled with equal propotion of salt and chorchal 150mm all round the pipe to complete depth the connection from the pipe to conduit etc is to be established thorugh gi wire of size as per isi specification | Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |
4007457 | 155123 | None | code78 | Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable with operate on 230v 50Hz AC Supply Complete | Each | 2969.0 | 2969.0 | 2.0 | False | None | None | False | None | False | 5938.0 | 0 |
4007458 | 155123 | None | code79 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200mm) Regular model | Each | 2984.0 | 2984.0 | 5.0 | False | None | None | False | None | False | 14920.0 | 0 |
4007459 | 155123 | None | code80 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 690.0 | 690.0 | 9.0 | False | None | None | False | None | False | 6210.0 | 0 |
4007460 | 155123 | None | code81 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Nos | 63.0 | 63.0 | 5.0 | False | None | None | False | None | False | 315.0 | 0 |
4007461 | 155123 | None | code82 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 10.0 | False | None | None | False | None | False | 1220.0 | 0 |
4007462 | 155123 | None | code83 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 351.0 | 351.0 | 5.0 | False | None | None | False | None | False | 1755.0 | 0 |
4007463 | 155123 | None | code84 | Fixing all types and all capacities of 1x4 /2x2 LED Light fittings indoor on the wall/ceiling/rafters/girders/with necessary supporting frame using 23/0.0076" twin twisted PVC insulated wires required nos of round blocks and clamps | Each | 490.0 | 490.0 | 2.0 | False | None | None | False | None | False | 980.0 | 0 |