createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726577228286
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1700.00
emd155000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-09-2024 16:30:00
tenderQueryClose25-09-2024 11:00:00
technicalBidOpen26-09-2024 16:35:00
publishedDate17-09-2024 18:34:33
publishedByPostDMA_EE1_CC_KLB
publishedByUserKPE22107 - PURUSHOTTAM
bidValidityPeriod90
noOfCalls3
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonPURSHOTTAM
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9620341599
tenderSupplierListNone
tenderSchedule
createdTs1726577228289
version21
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT12366/CALL-3
titleSupply, Installation and commissioning of 500 LPH FRP water purification plant, Construction of shed, Drilling of Borewell and Providing electricity in kalaburagi city (15th FC 2023-24)(Est Cost Rs.77.50 Lakhs)(Category-Others)
descriptionSupply, Installation and commissioning of 500 LPH FRP water purification plant, Construction of shed, Drilling of Borewell and Providing electricity in kalaburagi city (15th FC 2023-24)(Est Cost Rs.77.50 Lakhs)(Category-Others)
categoryWORKS
categoryTextWorks
ecv6769475.54
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2161
locationNameDMA City Corporation Kalaburagi
provisionalAmount7750000.0
groupOverheadTotal0.0
fileNumberKMP/EE/DB/15thFC/03/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17265772280000NoneNoneOther WorksSupply, Installation and commissioning of 500 LPH FRP water purification plant, Construction of shed, Drilling of Borewell and Providing electricity in kalaburagi city (15th FC 2023-24)(Est Cost Rs.77.50 Lakhs)(Category-ST)6769475.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4017576155630None001Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc complete (KPWD Volume-V SR 2023-24, Item no.12.4 Pg no.140)Each5552.45552.47.0FalseNoneNoneFalseNoneFalse38866.80
4017577155630None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.1 Pg no.139) Borewell depth of 0 to 50 Mtrsm388.5388.5350.0FalseNoneNoneFalseNoneFalse135975.00
4017578155630None003Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.2 Pg no.139) Borewell depth of 50 to 100 Mtrsm487.2487.2350.0FalseNoneNoneFalseNoneFalse170520.00
4017579155630None004Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.3 Pg no.139) Borewell depth of 100 to 150 Mtrsm517.65517.65175.0FalseNoneNoneFalseNoneFalse90588.750
4017580155630None005PVC pipes of 6 Kg/cm2 for 200mm(6.233) (KPWD Volume-V SR 2023-24, Sl.no.678 Pg no.A-45)(200mm dia 6 Kg/cm2)m740.25740.2563.0FalseNoneNoneFalseNoneFalse46635.750
4017581155630None006PVC pipes of 6 Kg/cm2 for 140mm(3.097) (KPWD Volume-V SR 2023-24, Sl.no.659 Pg no.A-44)(140mm dia Kg/cm2)m359.1359.1875.0FalseNoneNoneFalseNoneFalse314212.50
4017582155630None007Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 1.50 HP/1.1KW, 20 STG (KPWD Volume-V SR 2023-24, Item no.13.7.7 Pg no.150)Each19128.919128.97.0FalseNoneNoneFalseNoneFalse133902.30
4017583155630None008Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark (KPWD Volume-V SR 2023-24, Item no.13.30 Pg no.155)Set4725.04725.07.0FalseNoneNoneFalseNoneFalse33075.00
4017584155630None009Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (KPWD Volume-V SR 2023-24, Item no.12.34 Pg no.143)Each172.2172.27.0FalseNoneNoneFalseNoneFalse1205.40
4017585155630None010Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.(KPWD Volume-V SR 2023-24, Item no.13.22.3 Pg no.154) 1x3x4 Sqmm141.75141.75875.0FalseNoneNoneFalseNoneFalse124031.250
4017586155630None011Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (KPWD Volume-V SR 2023-24, Item no.13.36 Pg no.156)m141.75141.75175.0FalseNoneNoneFalseNoneFalse24806.250
4017587155630None012Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments size a.63mm (KPWD Volume-V SR 2023-24, Item no.13.23 Pg no.154)Each436.8436.87.0FalseNoneNoneFalseNoneFalse3057.60
4017588155630None013Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (KPWD Volume-V SR 2023-24, Item no.13.25.1 Pg no.154)Size 50 mmEach1312.51312.57.0FalseNoneNoneFalseNoneFalse9187.50
4017589155630None014Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(KPWD Volume-V SR 2023-24, Item no.13.23.2 Pg no.155)3 to 6 HP pumpsEach10027.510027.57.0FalseNoneNoneFalseNoneFalse70192.50
4017590155630None015Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (KPWD Volume-V SR 2023-24, Item no.13.25 Pg no.155)Kvar577.5577.57.0FalseNoneNoneFalseNoneFalse4042.50
4017591155630None016Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (KPWD Volume-V SR 2023-24, Item no.13.26 Pg no.155)Per 3 Poles1207.51207.57.0FalseNoneNoneFalseNoneFalse8452.50
4017592155630None017Polythylene pipes high density (HDPE) 40mm external dia (PRE WS DSR, klb for 2019-20 Pno 26 sl no 0304)m152.54152.54868.0FalseNoneNoneFalseNoneFalse132404.720
4017593155630None018Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (KPWD Volume-V SR 2023-24, Item no.13.32 Pg no.156)Job6825.06825.07.0FalseNoneNoneFalseNoneFalse47775.00
4017594155630None019Labour charges for perforation & erection of 140 and 110mm dia PVC pipes (Rate approved by the Executive Engineer)Job55.055.0875.0FalseNoneNoneFalseNoneFalse48125.00
4017595155630None020Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work (KPWD Volume-V SR 2023-24, Item no.13.34 Pg no.156)Job1522.51522.57.0FalseNoneNoneFalseNoneFalse10657.50
4017596155630None021Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.(KPWD Volume-V SR 2023-24, Item no.13.39 Pg no.157)Job3937.53937.57.0FalseNoneNoneFalseNoneFalse27562.50
4017597155630None022Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(KPWD Volume-I SR 2023-24, Item no.1.12 Pg no.8)Cum99.7599.7529.82FalseNoneNoneFalseNoneFalse2974.5450
4017598155630None023Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(KPWD Volume-I SR 2023-24, Item no.2.1.2 Pg no.15) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.229.82FalseNoneNoneFalseNoneFalse177345.5040
4017599155630None024Providing and laying in position Reinforced Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (KPWD Volume-I SR 2023-24, Item no.2.2.1 Pg no.15)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3522.82FalseNoneNoneFalseNoneFalse150642.8070
4017600155630None025Additional 5% for formworkCum330.07330.0722.82FalseNoneNoneFalseNoneFalse7532.19740
4017601155630None026Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(KPWD Volume-I SR 2023-24, Item no.2.11c Pg no.18)c) sub structure of bridgesKg90754.6590754.651.015FalseNoneNoneFalseNoneFalse92115.969750
4017602155630None027Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(KPWD Volume-II SR 2023-24, Item no.9.22.2 Pg no.62)Sqm1392.31392.3106.54FalseNoneNoneFalseNoneFalse148335.6420
4017603155630None028Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each component(BWSSB Volume-V SR 2023-24, Item no.21.1.8 Pg no.247)Each322350.0322350.07.0FalseNoneNoneFalseNoneFalse2256450.00
4017604155630None029Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.1.1.1 Pg no.2)m69.069.0700.0FalseNoneNoneFalseNoneFalse48300.00
4017605155630None030Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet: Short point upto 3Mtr from tapping point to out let via switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.1 Pg no.5)Point285.0285.014.0FalseNoneNoneFalseNoneFalse3990.00
4017606155630None031Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.:Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.2 Pg no.5)Point394.0394.021.0FalseNoneNoneFalseNoneFalse8274.00
4017607155630None032Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.: Long point above 6Mtr upto 10Mtr from tapping point to out let via switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.3 Pg no.5)Point570.0570.042.0FalseNoneNoneFalseNoneFalse23940.00
4017608155630None033Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 Confirming to latest amendments: 1.5 mm2 (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.3.2 Pg no.5)m26.026.0700.0FalseNoneNoneFalseNoneFalse18200.00
4017609155630None034Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 Confirming to latest amendments: 2.5 mm2 (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.3.3 Pg no.5)m42.042.0700.0FalseNoneNoneFalseNoneFalse29400.00
4017610155630None035Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.3.5 Pg no.8)Each219.0219.014.0FalseNoneNoneFalseNoneFalse3066.00
4017611155630None036Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.3.6 Pg no.8)Each261.0261.014.0FalseNoneNoneFalseNoneFalse3654.00
4017612155630None037Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.4.5 Pg no.8)Each261.0261.014.0FalseNoneNoneFalseNoneFalse3654.00
4017613155630None038Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.4.6 Pg no.8)Each319.0319.014.0FalseNoneNoneFalseNoneFalse4466.00
4017614155630None039Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switchch (KPWD Electrical Part III Item no.3.6.1 Pg no.9)Each102.0102.070.0FalseNoneNoneFalseNoneFalse7140.00
4017615155630None040Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch PWD Electrical Part III Item no.3.6.10 Pg no.9)Each326.0326.07.0FalseNoneNoneFalseNoneFalse2282.00
4017616155630None041Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Three Pin Top PWD Electrical Part III Item no.3.14.4 Pg no.10)No87.087.021.0FalseNoneNoneFalseNoneFalse1827.00
4017617155630None041Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A Three Way 5 Pin Socket PWD Electrical Part III Item no.3.14.12 Pg no.10)No115.0115.014.0FalseNoneNoneFalseNoneFalse1610.00
4017618155630None042Supplying & Fixing of 70-150 W lamp holder 2 Pin 6A Lamp holder PWD Electrical Part III Item no.12.46 Pg no.52)No63.063.035.0FalseNoneNoneFalseNoneFalse2205.00
4017619155630None043Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders PWD Electrical Part III Item no.13.7 Pg no.56)Each122.0122.035.0FalseNoneNoneFalseNoneFalse4270.00
4017620155630None045Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP & N PWD Electrical Part III Item no.5.11.2 Pg no.18)Each1186.01186.07.0FalseNoneNoneFalseNoneFalse8302.00
4017621155630None046Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP PWD Electrical Part III Item no.5.18.1 Pg no.17)Each415.0415.014.0FalseNoneNoneFalseNoneFalse5810.00
4017622155630None047Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified (PWD Electrical Part III Item no.51.04 Pg no.23)No2172.02172.014.0FalseNoneNoneFalseNoneFalse30408.00
4017623155630None048LT AC 3 Phase 4 Wire, 10-60 Amps Smart Energy Meter, Class 1.0 Accuracy with RF Communication Module (PWD Electrical Part III Item no.53.17 Pg no.24)Each3282.03282.07.0FalseNoneNoneFalseNoneFalse22974.00
4017624155630None049Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model (PWD Electrical Part III Item no. 6.3.1 Pg no.30)Each2984.02984.07.0FalseNoneNoneFalseNoneFalse20888.00
4017625155630None0501.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) (PWD Electrical Part III Item no. 32.03 Pg no.13)Km118004.0118004.00.35FalseNoneNoneFalseNoneFalse41301.40
4017626155630None051Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil (PWD Electrical Part III Item no. 29.02 Pg no.63)Cum260.0260.070.0FalseNoneNoneFalseNoneFalse18200.00
4017627155630None052Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil (PWD Electrical Part III Item no. 29.03 Pg no.63)Cum389.0389.028.0FalseNoneNoneFalseNoneFalse10892.00
4017628155630None053Cutting of Road surface for cable trenches and disposing of the excavated earth, as directed including Barricading, Danger Lighting then Refilling the Cable Trenches. Tar Road (PWD Electrical Part III Item no. 29.10 Pg no.64)Cum536.0536.014.0FalseNoneNoneFalseNoneFalse7504.00
4017629155630None054Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable (PWD Electrical Part III Item no. 21.05 Pg no.52)Km20886.020886.00.35FalseNoneNoneFalseNoneFalse7310.10
4017630155630None055Supplying and laying double walled corrugated(DWC) HDPE pipe including all necessary connecting sockets/couplings/Tees/Bends/Ends-caps of same materials in existing trench as per IS 14930 part II suitable for drawing under ground cables. PWD Electrical DSR 2014-15 50mm OD/38mm IDMtr151.0151.0245.0FalseNoneNoneFalseNoneFalse36995.00
4017631155630None056Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mm (PWD Electrical Item no. 5.44.2 Pg no.21)Each6163.06163.07.0FalseNoneNoneFalseNoneFalse43141.00
4017632155630None057Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 16 A (PWD Electrical Item no. 5.7.1 Pg no.14)Each157.0157.021.0FalseNoneNoneFalseNoneFalse3297.00
4017633155630None058GESCOM CHARGES (AS PER INTIMATION AMOUNT)Each20000.020000.07.0FalseNoneNoneFalseNoneFalse140000.00
4017634155630None059Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Manual Means) CC PORTION (CSR Item no. 1.6.1 Pg no.6)Cum508.2508.22.7FalseNoneNoneFalseNoneFalse1372.140
4017635155630None060Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Manual Means) EARTH PORTION (CSR Item no. 1.6.2 Pg no.6)Cum508.2508.23.6FalseNoneNoneFalseNoneFalse1829.520
4017636155630None061Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (CSR Item no. I- 1.10 Pg no.7)Cum168.0168.06.3FalseNoneNoneFalseNoneFalse1058.40
4017637155630None062GI Pipes Providing Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning.(contractor will make his own arrangement for procuring water for testing) for Heavy duty GI Pipe etc. Complete. (BWSSB SOR Item no. 11.2.4 Pg no.127)Rmtr400.05400.0560.0FalseNoneNoneFalseNoneFalse24003.00
4017638155630None063Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth (PWD UNI SR 2023-24 Vol-I Item No: 1.5.1 Pg.No 6)Cum313.95313.9544.87FalseNoneNoneFalseNoneFalse14086.93650
4017639155630None064Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m (PWD UNI SR 2023-24 Vol-I Item No: 1.5.2 Pg.No 6)Cum467.25467.2542.0FalseNoneNoneFalseNoneFalse19624.50
4017640155630None065Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.1.4 Pg.No 15)Cum5947.25947.22.87FalseNoneNoneFalseNoneFalse17068.4640
4017641155630None066Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.2.1 Pg.No 15)(Additional 5 % for formwork)Cum330.07330.0722.82FalseNoneNoneFalseNoneFalse7532.19740
4017642155630None067Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt,dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2 (PWD UNI SR 2023-24 Chapter No:2 Item No: 13.14 Pg.No 123)Cum88.288.244.8FalseNoneNoneFalseNoneFalse3951.360
4017643155630None068Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (PWD UNI SR 2023-24 Vol-2 Item No: 17.1 Pg.No 175)Cum1052.11052.128.0FalseNoneNoneFalseNoneFalse29458.80
4017644155630None069Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. (PWD UNI SR 2023-24 Vol-2 Item No: 17.2 Pg.No 175)Cum1245.31245.328.0FalseNoneNoneFalseNoneFalse34868.40
4017645155630None070Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1251.61251.628.0FalseNoneNoneFalseNoneFalse35044.80
4017646155630None071Stainless steel shed as per specification enclosed inclusive of assembly, with one year maintenanceNo179233.0179233.07.0FalseNoneNoneFalseNoneFalse1254631.00
4017647155630None072Installation chargesNo30000.030000.07.0FalseNoneNoneFalseNoneFalse210000.00
4017648155630None073Transportation ChargesNo30000.030000.07.0FalseNoneNoneFalseNoneFalse210000.00
4017649155630None074Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportring back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box (8 Module) (PWD Electrical Part III Item no.3.5.5 Pg no.8)Each284.0284.014.0FalseNoneNoneFalseNoneFalse3976.00
4017650155630None075Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportring back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box (10-12 Module) (PWD Electrical Part III Item no.3.5.6 Pg no.8)Each344.0344.014.0FalseNoneNoneFalseNoneFalse4816.00
4017651155630None076Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.2.1 Pg.No 15)Cum6601.356601.353.36FalseNoneNoneFalseNoneFalse22180.5360
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17265772280000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17265772280000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17265772280000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17265772280000NoneNoneELIGIBILITYAs per Tender DocumentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of workPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Drilling of Borewell 700 M
NoneNoneNoneNoneOthers -- 500LPH SS Water Purification Plant 6 Nos
NoneNoneNoneNoneOthers -- SS Shed/FRP/UPVC for RO Plant 6 Nos
NoneNoneNoneNoneSatisfactorily completed, as prime contractor at least one similar work such as Providing, Installation and commissioning of RO plant (RO plus UV) Water Purification plant work of value not less than Rs. 38.75 Lakhs.Past ExperienceAS PER BID DOCUMENT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAchieved in at least two financial years an average financial turnover in all classes of civil engineering construction works only of Rs. 77.50 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and/or availability of credit facilities of no less than Rs. 23.25 Lakhs Credit lines/letter of credit/ certificates from the banks for meeting the fund requirement etc conditional Line of credit will be rejectedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Line of credit
NoneNoneNoneNoneESI & PF Registration Certificate to be Enclosed.OthersESI & PF Registration Certificate to be Enclosed.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- ESI & PF Registration Certificate to be Enclosed.
NoneNoneNoneNoneTender Bid Capacity the bidder should upload the ongoing works in HandOthersTender Bid Capacity the bidder should upload the ongoing works in Hand
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender Bid Capacity the bidder should upload the ongoing works in Hand
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Tender bid capacity should be upload the ongoing works in handTrueTechnical Bid
ESI & PF Registration Certificate to be EnclosedTrueTechnical Bid
Line of creditTrueTechnical Bid
As per Tender DocumentTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone