4017576 | 155630 | None | 001 | Geophysical investigation at site for sinking borewells for Providing
drinking water to the habitation either through the Hand Pump MWS
or P.W.S.S, by vertical electrical sounding by adopting Venner or
Schlumbergers's method, including reconnaissance survey of geological
formation. Geophysical investigation of existing ground water in the
vicinity, its quality, quantity and acceptability of the users, indicating
the location of the site, recommended depth of casing pipe required to
seal the top unconsolidated formation including an extra depth of 1.0
metre in consolidated formation for proper seating of casing pipe, depth
of drilling required to cover full depth of aquifer proposed to be tapped,
probable yield and other information required including transportation
of instruments and accessories to work site, engaging technical personal
and labour required etc. NOTE: 1) Additional rate on item 1&2 is
allowed for drilling in over burden and fixing Casing pipes beyond 20
M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the
depth of casing pipe fixed excluding initial depth of 20M and projection
above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry
Borewell towards yield test etc complete (KPWD Volume-V SR 2023-24, Item no.12.4 Pg no.140) | Each | 5552.4 | 5552.4 | 7.0 | False | None | None | False | None | False | 38866.8 | 0 |
4017577 | 155630 | None | 002 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.1 Pg no.139) Borewell depth of 0 to 50 Mtrs | m | 388.5 | 388.5 | 350.0 | False | None | None | False | None | False | 135975.0 | 0 |
4017578 | 155630 | None | 003 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.2 Pg no.139) Borewell depth of 50 to 100 Mtrs | m | 487.2 | 487.2 | 350.0 | False | None | None | False | None | False | 170520.0 | 0 |
4017579 | 155630 | None | 004 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth) (KPWD Volume-V SR 2023-24, Item no.12.1.3 Pg no.139) Borewell depth of 100 to 150 Mtrs | m | 517.65 | 517.65 | 175.0 | False | None | None | False | None | False | 90588.75 | 0 |
4017580 | 155630 | None | 005 | PVC pipes of 6 Kg/cm2 for 200mm(6.233) (KPWD Volume-V SR 2023-24, Sl.no.678 Pg no.A-45)(200mm dia 6 Kg/cm2) | m | 740.25 | 740.25 | 63.0 | False | None | None | False | None | False | 46635.75 | 0 |
4017581 | 155630 | None | 006 | PVC pipes of 6 Kg/cm2 for 140mm(3.097) (KPWD Volume-V SR 2023-24, Sl.no.659 Pg no.A-44)(140mm dia Kg/cm2) | m | 359.1 | 359.1 | 875.0 | False | None | None | False | None | False | 314212.5 | 0 |
4017582 | 155630 | None | 007 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)
suitable for bore well confirming to IS 8034-2000 specifications, to work
site with testing of as per instructions of engineer incharge of work and
latest amendments etc complete 1.50 HP/1.1KW, 20 STG (KPWD Volume-V SR 2023-24, Item no.13.7.7 Pg no.150) | Each | 19128.9 | 19128.9 | 7.0 | False | None | None | False | None | False | 133902.3 | 0 |
4017583 | 155630 | None | 008 | Supply and delivery at site Accessories for Single Phase pumpset like
SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation
Tape etc complete with ISI mark (KPWD Volume-V SR 2023-24, Item no.13.30 Pg no.155) | Set | 4725.0 | 4725.0 | 7.0 | False | None | None | False | None | False | 33075.0 | 0 |
4017584 | 155630 | None | 009 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness
of plate used for covering one end shall be 3mm (minimum). The
dimensions of caps and colars shall be strictly as per IS 1239 (Part-II)
1982 with all amendments including cost of material and labour charges
for fixing, if any etc. complete with all lead and lifts and as directed by
the Engineer in charge (KPWD Volume-V SR 2023-24, Item no.12.34 Pg no.143) | Each | 172.2 | 172.2 | 7.0 | False | None | None | False | None | False | 1205.4 | 0 |
4017585 | 155630 | None | 010 | Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments.(KPWD Volume-V SR 2023-24, Item no.13.22.3 Pg no.154) 1x3x4 Sqm | m | 141.75 | 141.75 | 875.0 | False | None | None | False | None | False | 124031.25 | 0 |
4017586 | 155630 | None | 011 | Providing main connection from pole PVC insulated sheathed steel wire
cable in new trench as per IS 1554/ 1988 with latest amendments with
ISI mark from KPTCL pole to meter board unit. (KPWD Volume-V SR 2023-24, Item no.13.36 Pg no.156) | m | 141.75 | 141.75 | 175.0 | False | None | None | False | None | False | 24806.25 | 0 |
4017587 | 155630 | None | 012 | Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments size a.63mm (KPWD Volume-V SR 2023-24, Item no.13.23 Pg no.154) | Each | 436.8 | 436.8 | 7.0 | False | None | None | False | None | False | 3057.6 | 0 |
4017588 | 155630 | None | 013 | Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments (KPWD Volume-V SR 2023-24, Item no.13.25.1 Pg no.154)Size 50 mm | Each | 1312.5 | 1312.5 | 7.0 | False | None | None | False | None | False | 9187.5 | 0 |
4017589 | 155630 | None | 014 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING
for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable
for respective HP 1 No. Electrcal Protection Like single Phase preventor,
under voltage over Volage, under current over current & dry run
protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.(KPWD Volume-V SR 2023-24, Item no.13.23.2 Pg no.155)3 to 6 HP pumps | Each | 10027.5 | 10027.5 | 7.0 | False | None | None | False | None | False | 70192.5 | 0 |
4017590 | 155630 | None | 015 | Supply and delivery at site best indigenous brand new power capacitor as
per IS 2834/1986 with latest amendments with KPTCL authorities and
erection, electrification and commissioning of the same at the location
of respective pump sets. (KPWD Volume-V SR 2023-24, Item no.13.25 Pg no.155) | Kvar | 577.5 | 577.5 | 7.0 | False | None | None | False | None | False | 4042.5 | 0 |
4017591 | 155630 | None | 016 | Supply and delivery at site delivery of best indigenous brand new MCB
(Miniature Circuit Breakers) of required capacity as per IS 88228/1978
and its latest amendments and with ISI Mark of 6/10/16/20/25/40
Amps with scalable box. (KPWD Volume-V SR 2023-24, Item no.13.26 Pg no.155) | Per 3 Poles | 1207.5 | 1207.5 | 7.0 | False | None | None | False | None | False | 8452.5 | 0 |
4017592 | 155630 | None | 017 | Polythylene pipes high density (HDPE) 40mm external dia (PRE WS DSR, klb for 2019-20 Pno 26 sl no 0304) | m | 152.54 | 152.54 | 868.0 | False | None | None | False | None | False | 132404.72 | 0 |
4017593 | 155630 | None | 018 | Labour charges for Erection, Electrification and commissioning of Pump
sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and
water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary
tests as per specifications, with testing of as per instructions of engineer
incharge of work.
(KPWD Volume-V SR 2023-24, Item no.13.32 Pg no.156) | Job | 6825.0 | 6825.0 | 7.0 | False | None | None | False | None | False | 47775.0 | 0 |
4017594 | 155630 | None | 019 | Labour charges for perforation & erection of 140 and 110mm dia PVC pipes (Rate approved by the Executive Engineer) | Job | 55.0 | 55.0 | 875.0 | False | None | None | False | None | False | 48125.0 | 0 |
4017595 | 155630 | None | 020 | Labour charges for erection of outdoor type panel board and meter board
units with all necessary materials and labour, tools and equipments
including providing cement concrete foundation bed etc., complete
as per specification, with testing of as per instructions of engineer
incharge of work (KPWD Volume-V SR 2023-24, Item no.13.34 Pg no.156) | Job | 1522.5 | 1522.5 | 7.0 | False | None | None | False | None | False | 10657.5 | 0 |
4017596 | 155630 | None | 021 | Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia.(KPWD Volume-V SR 2023-24, Item no.13.39 Pg no.157) | Job | 3937.5 | 3937.5 | 7.0 | False | None | None | False | None | False | 27562.5 | 0 |
4017597 | 155630 | None | 022 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work.(KPWD Volume-I SR 2023-24, Item no.1.12 Pg no.8) | Cum | 99.75 | 99.75 | 29.82 | False | None | None | False | None | False | 2974.545 | 0 |
4017598 | 155630 | None | 023 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.(KPWD Volume-I SR 2023-24, Item no.2.1.2 Pg no.15) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 29.82 | False | None | None | False | None | False | 177345.504 | 0 |
4017599 | 155630 | None | 024 | Providing and laying in position Reinforced Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (KPWD Volume-I SR 2023-24, Item no.2.2.1 Pg no.15)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 22.82 | False | None | None | False | None | False | 150642.807 | 0 |
4017600 | 155630 | None | 025 | Additional 5% for formwork | Cum | 330.07 | 330.07 | 22.82 | False | None | None | False | None | False | 7532.1974 | 0 |
4017601 | 155630 | None | 026 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(KPWD Volume-I SR 2023-24, Item no.2.11c Pg no.18)c) sub structure of bridges | Kg | 90754.65 | 90754.65 | 1.015 | False | None | None | False | None | False | 92115.96975 | 0 |
4017602 | 155630 | None | 027 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately).Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately).Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately).(KPWD Volume-II SR 2023-24, Item no.9.22.2 Pg no.62) | Sqm | 1392.3 | 1392.3 | 106.54 | False | None | None | False | None | False | 148335.642 | 0 |
4017603 | 155630 | None | 028 | Water purification plants: Providing, Installation and Commissioning of
automatic Water purification plant (RO+UF) with all accessories piping,
product water tank on single phase power supply as per the enclosed
detailed Technical Specifications including cost of material, loading
and unloading and as directed by the Engineer in charge. (Ref- detailed
specification enclosed seperatly). Note:- 1.The above rates mentioned
are only for the preparation of estimate purpose. 2. All items are to be of
BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for
procurement. 4. No direct payment should be made under any situation
or condition or on any account. 5. After commissioning of plant necessary
testing to be done for the satisfactory of Engineer Incharge. Note : Refer
the ANNEXURE : F for Detailed Specification of Each component(BWSSB Volume-V SR 2023-24, Item no.21.1.8 Pg no.247) | Each | 322350.0 | 322350.0 | 7.0 | False | None | None | False | None | False | 2256450.0 | 0 |
4017604 | 155630 | None | 029 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.
19/20 mm dia 2 mm thick (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.1.1.1 Pg no.2) | m | 69.0 | 69.0 | 700.0 | False | None | None | False | None | False | 48300.0 | 0 |
4017605 | 155630 | None | 030 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet: Short point upto 3Mtr from tapping point to out let via switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.1 Pg no.5) | Point | 285.0 | 285.0 | 14.0 | False | None | None | False | None | False | 3990.0 | 0 |
4017606 | 155630 | None | 031 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet.:Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.2 Pg no.5) | Point | 394.0 | 394.0 | 21.0 | False | None | None | False | None | False | 8274.0 | 0 |
4017607 | 155630 | None | 032 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet.:
Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.1.3 Pg no.5) | Point | 570.0 | 570.0 | 42.0 | False | None | None | False | None | False | 23940.0 | 0 |
4017608 | 155630 | None | 033 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 Confirming to latest amendments: 1.5 mm2 (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.3.2 Pg no.5) | m | 26.0 | 26.0 | 700.0 | False | None | None | False | None | False | 18200.0 | 0 |
4017609 | 155630 | None | 034 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 Confirming to latest amendments: 2.5 mm2 (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.2.3.3 Pg no.5) | m | 42.0 | 42.0 | 700.0 | False | None | None | False | None | False | 29400.0 | 0 |
4017610 | 155630 | None | 035 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.3.5 Pg no.8) | Each | 219.0 | 219.0 | 14.0 | False | None | None | False | None | False | 3066.0 | 0 |
4017611 | 155630 | None | 036 | Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete.
10-12 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.3.6 Pg no.8) | Each | 261.0 | 261.0 | 14.0 | False | None | None | False | None | False | 3654.0 | 0 |
4017612 | 155630 | None | 037 | Supplying and flush mounting powder coated / galvanized metal box
suitable for mounting modular switch plates. The box should be firmly
flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.4.5 Pg no.8) | Each | 261.0 | 261.0 | 14.0 | False | None | None | False | None | False | 3654.0 | 0 |
4017613 | 155630 | None | 038 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way (KPWD Volume-6 SR 2023-24, PWD Electrical Part III Item no.3.4.6 Pg no.8) | Each | 319.0 | 319.0 | 14.0 | False | None | None | False | None | False | 4466.0 | 0 |
4017614 | 155630 | None | 039 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6A One Way Switchch (KPWD Electrical Part III Item no.3.6.1 Pg no.9) | Each | 102.0 | 102.0 | 70.0 | False | None | None | False | None | False | 7140.0 | 0 |
4017615 | 155630 | None | 040 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32A DP Switch PWD Electrical Part III Item no.3.6.10 Pg no.9) | Each | 326.0 | 326.0 | 7.0 | False | None | None | False | None | False | 2282.0 | 0 |
4017616 | 155630 | None | 041 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Three Pin Top PWD Electrical Part III Item no.3.14.4 Pg no.10) | No | 87.0 | 87.0 | 21.0 | False | None | None | False | None | False | 1827.0 | 0 |
4017617 | 155630 | None | 041 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 16A Three Way 5 Pin Socket PWD Electrical Part III Item no.3.14.12 Pg no.10) | No | 115.0 | 115.0 | 14.0 | False | None | None | False | None | False | 1610.0 | 0 |
4017618 | 155630 | None | 042 | Supplying & Fixing of 70-150 W lamp holder 2 Pin 6A Lamp holder PWD Electrical Part III Item no.12.46 Pg no.52) | No | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 |
4017619 | 155630 | None | 043 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps On wall/ ceiling / Rafter / Girders PWD Electrical Part III Item no.13.7 Pg no.56) | Each | 122.0 | 122.0 | 35.0 | False | None | None | False | None | False | 4270.0 | 0 |
4017620 | 155630 | None | 045 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP & N PWD Electrical Part III Item no.5.11.2 Pg no.18) | Each | 1186.0 | 1186.0 | 7.0 | False | None | None | False | None | False | 8302.0 | 0 |
4017621 | 155630 | None | 046 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP PWD Electrical Part III Item no.5.18.1 Pg no.17) | Each | 415.0 | 415.0 | 14.0 | False | None | None | False | None | False | 5810.0 | 0 |
4017622 | 155630 | None | 047 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS
rod as ground rod, in earth pit of 300 mm width and
3300 mm depth and using 50x6 mm flat welded to
ground rod as terminal & connected to equipment
ground terminal using PVC Al wire as specified (PWD Electrical Part III Item no.51.04 Pg no.23) | No | 2172.0 | 2172.0 | 14.0 | False | None | None | False | None | False | 30408.0 | 0 |
4017623 | 155630 | None | 048 | LT AC 3 Phase 4 Wire, 10-60 Amps Smart Energy
Meter, Class 1.0 Accuracy with RF Communication
Module (PWD Electrical Part III Item no.53.17 Pg no.24) | Each | 3282.0 | 3282.0 | 7.0 | False | None | None | False | None | False | 22974.0 | 0 |
4017624 | 155630 | None | 049 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model (PWD Electrical Part III Item no. 6.3.1 Pg no.30) | Each | 2984.0 | 2984.0 | 7.0 | False | None | None | False | None | False | 20888.0 | 0 |
4017625 | 155630 | None | 050 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) (PWD Electrical Part III Item no. 32.03 Pg no.13) | Km | 118004.0 | 118004.0 | 0.35 | False | None | None | False | None | False | 41301.4 | 0 |
4017626 | 155630 | None | 051 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial
pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and
Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil (PWD Electrical Part III Item no. 29.02 Pg no.63) | Cum | 260.0 | 260.0 | 70.0 | False | None | None | False | None | False | 18200.0 | 0 |
4017627 | 155630 | None | 052 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial
pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and
Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil (PWD Electrical Part III Item no. 29.03 Pg no.63) | Cum | 389.0 | 389.0 | 28.0 | False | None | None | False | None | False | 10892.0 | 0 |
4017628 | 155630 | None | 053 | Cutting of Road surface for cable trenches and disposing of the excavated earth, as directed including Barricading, Danger Lighting then Refilling the Cable Trenches. Tar Road (PWD Electrical Part III Item no. 29.10 Pg no.64) | Cum | 536.0 | 536.0 | 14.0 | False | None | None | False | None | False | 7504.0 | 0 |
4017629 | 155630 | None | 054 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable (PWD Electrical Part III Item no. 21.05 Pg no.52) | Km | 20886.0 | 20886.0 | 0.35 | False | None | None | False | None | False | 7310.1 | 0 |
4017630 | 155630 | None | 055 | Supplying and laying double walled corrugated(DWC) HDPE pipe including all necessary connecting sockets/couplings/Tees/Bends/Ends-caps of same materials in existing trench as per IS 14930 part II suitable for drawing under ground cables. PWD Electrical DSR 2014-15 50mm OD/38mm ID | Mtr | 151.0 | 151.0 | 245.0 | False | None | None | False | None | False | 36995.0 | 0 |
4017631 | 155630 | None | 056 | Supply and Installation / Fixing / Provision of Outdoor type
Thermoplastic Modular Panel enclosure with transparent
Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof,
dust proof, water proof, corrosion proof having internally Embedded
gasket on both lid and flap suitable to fix Single Phase / Three Phase
Energy Meter in suitable base plate and having a provision for Fuse /
MCB cut-out with suitable transparent hinged flap opening for
operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mm (PWD Electrical Item no. 5.44.2 Pg no.21) | Each | 6163.0 | 6163.0 | 7.0 | False | None | None | False | None | False | 43141.0 | 0 |
4017632 | 155630 | None | 057 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 16 A (PWD Electrical Item no. 5.7.1 Pg no.14) | Each | 157.0 | 157.0 | 21.0 | False | None | None | False | None | False | 3297.0 | 0 |
4017633 | 155630 | None | 058 | GESCOM CHARGES (AS PER INTIMATION AMOUNT) | Each | 20000.0 | 20000.0 | 7.0 | False | None | None | False | None | False | 140000.0 | 0 |
4017634 | 155630 | None | 059 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Manual Means) CC PORTION (CSR Item no. 1.6.1 Pg no.6) | Cum | 508.2 | 508.2 | 2.7 | False | None | None | False | None | False | 1372.14 | 0 |
4017635 | 155630 | None | 060 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Manual Means) EARTH PORTION (CSR Item no. 1.6.2 Pg no.6) | Cum | 508.2 | 508.2 | 3.6 | False | None | None | False | None | False | 1829.52 | 0 |
4017636 | 155630 | None | 061 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (CSR Item no. I- 1.10 Pg no.7) | Cum | 168.0 | 168.0 | 6.3 | False | None | None | False | None | False | 1058.4 | 0 |
4017637 | 155630 | None | 062 | GI Pipes Providing Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning.(contractor will make his own arrangement for procuring water for testing) for Heavy duty GI Pipe etc. Complete. (BWSSB SOR Item no. 11.2.4 Pg no.127) | Rmtr | 400.05 | 400.05 | 60.0 | False | None | None | False | None | False | 24003.0 | 0 |
4017638 | 155630 | None | 063 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth (PWD UNI SR 2023-24 Vol-I Item No: 1.5.1 Pg.No 6) | Cum | 313.95 | 313.95 | 44.87 | False | None | None | False | None | False | 14086.9365 | 0 |
4017639 | 155630 | None | 064 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m (PWD UNI SR 2023-24 Vol-I Item No: 1.5.2 Pg.No 6) | Cum | 467.25 | 467.25 | 42.0 | False | None | None | False | None | False | 19624.5 | 0 |
4017640 | 155630 | None | 065 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.1.4 Pg.No 15) | Cum | 5947.2 | 5947.2 | 2.87 | False | None | None | False | None | False | 17068.464 | 0 |
4017641 | 155630 | None | 066 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.2.1 Pg.No 15)(Additional 5 % for formwork) | Cum | 330.07 | 330.07 | 22.82 | False | None | None | False | None | False | 7532.1974 | 0 |
4017642 | 155630 | None | 067 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt,dust, oil, grease, efflorescence and applying paint @ of 1
litre for 2 m2 (PWD UNI SR 2023-24 Chapter No:2 Item No: 13.14 Pg.No 123) | Cum | 88.2 | 88.2 | 44.8 | False | None | None | False | None | False | 3951.36 | 0 |
4017643 | 155630 | None | 068 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (PWD UNI SR 2023-24 Vol-2 Item No: 17.1 Pg.No 175) | Cum | 1052.1 | 1052.1 | 28.0 | False | None | None | False | None | False | 29458.8 | 0 |
4017644 | 155630 | None | 069 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. (PWD UNI SR 2023-24 Vol-2 Item No: 17.2 Pg.No 175) | Cum | 1245.3 | 1245.3 | 28.0 | False | None | None | False | None | False | 34868.4 | 0 |
4017645 | 155630 | None | 070 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to
2 mm in recharge pit, in required thickness over gravel layer, for all leads
& lifts, all complete as per direction of Engineer -in-charge. | Cum | 1251.6 | 1251.6 | 28.0 | False | None | None | False | None | False | 35044.8 | 0 |
4017646 | 155630 | None | 071 | Stainless steel shed as per specification enclosed inclusive of assembly, with one year maintenance | No | 179233.0 | 179233.0 | 7.0 | False | None | None | False | None | False | 1254631.0 | 0 |
4017647 | 155630 | None | 072 | Installation charges | No | 30000.0 | 30000.0 | 7.0 | False | None | None | False | None | False | 210000.0 | 0 |
4017648 | 155630 | None | 073 | Transportation Charges | No | 30000.0 | 30000.0 | 7.0 | False | None | None | False | None | False | 210000.0 | 0 |
4017649 | 155630 | None | 074 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportring back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box (8 Module) (PWD Electrical Part III Item no.3.5.5 Pg no.8) | Each | 284.0 | 284.0 | 14.0 | False | None | None | False | None | False | 3976.0 | 0 |
4017650 | 155630 | None | 075 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportring back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box (10-12 Module) (PWD Electrical Part III Item no.3.5.6 Pg no.8) | Each | 344.0 | 344.0 | 14.0 | False | None | None | False | None | False | 4816.0 | 0 |
4017651 | 155630 | None | 076 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD UNI SR 2023-24 Chapter No:2 Item No: 2.2.1 Pg.No 15) | Cum | 6601.35 | 6601.35 | 3.36 | False | None | None | False | None | False | 22180.536 | 0 |