4013484 | 155451 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 13.44 | False | None | None | False | None | False | 1340.64 | 0 |
4013485 | 155451 | None | code02 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. | Cum | 5947.2 | 5947.2 | 0.84 | False | None | None | False | None | False | 4995.648 | 0 |
4013486 | 155451 | None | code03 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 8.748 | False | None | None | False | None | False | 51539.2794 | 0 |
4013487 | 155451 | None | code04 | RCC hume pipe Circular pump house: Providing precast RCC Circular
Hume pipe pump house with M.S door and RCC conical roof as per
specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5
Mtr. With Wall thickness 65mm etc. complete. | Each | 17221.05 | 17221.05 | 3.0 | False | None | None | False | None | False | 51663.15 | 0 |
4013488 | 155451 | None | code05 | Erection and positioning of RCC Hume pipe pump house/Cistern onsize stone masory platform including transportation charges andhandling,finishing with all necessary tools ,plants and materialsetc.,complete as directed by the Engineer in charge of the work. | Each | 1976.1 | 1976.1 | 3.0 | False | None | None | False | None | False | 5928.3 | 0 |
4013489 | 155451 | None | code06 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 24.48 | False | None | None | False | None | False | 8559.432 | 0 |
4013490 | 155451 | None | code07 | Providing and fixing brass stop cock of approved quality | No | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 |
4013491 | 155451 | None | code08 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy
Duty GI Pipe etc. complete.Light Duty GI pipe of 25mm dia | Mtr | 303.45 | 303.45 | 60.0 | False | None | None | False | None | False | 18207.0 | 0 |
4013492 | 155451 | None | code09 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 648.9 | 648.9 | 45.0 | False | None | None | False | None | False | 29200.5 | 0 |
4013493 | 155451 | None | code10 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy
Duty GI Pipe etc. complete Light Duty GI pipe of 50mm dia | m | 464.1 | 464.1 | 150.0 | False | None | None | False | None | False | 69615.0 | 0 |
4013494 | 155451 | None | code11 | Providing wrought mild steel (galvanized) GI collar confirming to IS
1239-II, 1991 with latest amendments if any. 150mm dia | Each | 729.75 | 729.75 | 25.0 | False | None | None | False | None | False | 18243.75 | 0 |
4013495 | 155451 | None | code12 | Providing Submersible Pump Set of 100mm dia suitable for bore well andconfirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low voltMotor as per specifications, to work site as per necessary ammendmentsand instructions of engineer incharge of work. | Each | 27720.0 | 27720.0 | 1.0 | False | None | None | False | None | False | 27720.0 | 0 |
4013496 | 155451 | None | code13 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
4013497 | 155451 | None | code14 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 Sqm | m | 141.75 | 141.75 | 85.0 | False | None | None | False | None | False | 12048.75 | 0 |
4013498 | 155451 | None | code15 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type. NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter. | Each | 11025.0 | 11025.0 | 1.0 | False | None | None | False | None | False | 11025.0 | 0 |
4013499 | 155451 | None | code16 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 |
4013500 | 155451 | None | code17 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. | Kvar | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 |
4013501 | 155451 | None | code18 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. | Each | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 |
4013502 | 155451 | None | code19 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 |