1726378993000 | 0 | None | None | Buildings | Construction of Yoga Room and Panchakarma Room in Government Ayurvedic Clinic of Chikkahandigola Village, of Naragunda Constituency, Gadag Taluk (Continued Part) Under 2210-00-101-0-36 Head | 1672133.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4009743 | 155219 | None | CODE1.5.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such simillar works as per drawing and technical specification, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 242.0 | 242.0 | 26.91 | False | None | None | False | None | False | 6512.22 | 0 | 4009744 | 155219 | None | CODE2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggrregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost od steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Sqm | 5989.0 | 5989.0 | 3.27 | False | None | None | False | None | False | 19584.03 | 0 | 4009745 | 155219 | None | CODE5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Sqm | 6618.0 | 6618.0 | 18.62 | False | None | None | False | None | False | 123227.16 | 0 | 4009746 | 155219 | None | CODE1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Sqm | 266.0 | 266.0 | 32.44 | False | None | None | False | None | False | 8629.04 | 0 | 4009747 | 155219 | None | CODE6.4 | Filling in foundations with granite trap broken metal 100mm. and down size, with approved sand Including hand packing, ramming watering. Including cost of all materials and labour with lead upto 50m. and lift of 1.5m.complete as per specifications | Cum | 2682.0 | 2682.0 | 9.12 | False | None | None | False | None | False | 24459.84 | 0 | 4009748 | 155219 | None | CODE2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggrregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost od steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 6243.0 | 6243.0 | 7.56 | False | None | None | False | None | False | 47197.08 | 0 | 4009749 | 155219 | None | CODE.24.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | m | 6492.72 | 6492.72 | 3.6 | False | None | None | False | None | False | 23373.792 | 0 | 4009750 | 155219 | None | CODE2.5.1 | Providing and laying in position Reinforced cement concrete for all super structures of building, Irrigation works, Super structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | m | 10613.1 | 10613.1 | 3.97 | False | None | None | False | None | False | 42134.007 | 0 | 4009751 | 155219 | None | CODE2.5.1 | Providing and laying in position Reinforced cement concrete for all super structures of building, Irrigation works, Super structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 9364.5 | 9364.5 | 2.71 | False | None | None | False | None | False | 25377.795 | 0 | 4009752 | 155219 | None | CODE2.5.1 | Providing and laying in position Reinforced cement concrete for all super structures of building, Irrigation works, Super structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9988.8 | 9988.8 | 2.98 | False | None | None | False | None | False | 29766.624 | 0 | 4009753 | 155219 | None | CODE2.5.1 | Providing and laying in position Reinforced cement concrete for all super structures of building, Irrigation works, Super structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | m | 9364.5 | 9364.5 | 6.94 | False | None | None | False | None | False | 64989.63 | 0 | 4009754 | 155219 | None | CODE2.5.1 | Providing and laying in position Reinforced cement concrete for all super structures of building, Irrigation works, Super structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.2-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9052.35 | 9052.35 | 0.22 | False | None | None | False | None | False | 1991.517 | 0 | 4009755 | 155219 | None | CODE11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specification . (The laps and wastages shall not be measured separately | Kg | 89.55 | 89.55 | 1837.13 | False | None | None | False | None | False | 164514.9915 | 0 | 4009756 | 155219 | None | CODE6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8220.0 | 8220.0 | 26.59 | False | None | None | False | None | False | 218569.8 | 0 | 4009757 | 155219 | None | CODE261 | Cuddapah slab 2.5 cm thick ,(Material components (material component | Sqm | 462.0 | 462.0 | 5.4 | False | None | None | False | None | False | 2494.8 | 0 | 4009758 | 155219 | None | CODE256 | Granite of any colour, 18 mm thick (slab area above 0.50 m2) | Sqm | 1800.0 | 1800.0 | 1.8 | False | None | None | False | None | False | 3240.0 | 0 | 4009759 | 155219 | None | CODE14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of
fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm | Each | 5082.0 | 5082.0 | 2.0 | False | None | None | False | None | False | 10164.0 | 0 | 4009760 | 155219 | None | CODE12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specification | Cum | 124202.0 | 124202.0 | 0.17 | False | None | None | False | None | False | 21114.34 | 0 | 4009761 | 155219 | None | CODE12.21 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specification (excluding cost of fixtures) | Sqm | 5742.0 | 5742.0 | 6.3 | False | None | None | False | None | False | 36174.6 | 0 | 4009762 | 155219 | None | CODE8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work | Sqm | 53.0 | 53.0 | 17.01 | False | None | None | False | None | False | 901.53 | 0 | 4009763 | 155219 | None | CODE8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work | Sqm | 167.0 | 167.0 | 14.18 | False | None | None | False | None | False | 2368.06 | 0 | 4009764 | 155219 | None | CODE8.4.1 | Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification and the direction of engineer incharge of work | Sqm | 323.0 | 323.0 | 591.86 | False | None | None | False | None | False | 191170.78 | 0 | 4009765 | 155219 | None | CODE8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 89.0 | 89.0 | 391.52 | False | None | None | False | None | False | 34845.28 | 0 | 4009766 | 155219 | None | CODE9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete | Sqm | 1175.0 | 1175.0 | 96.15 | False | None | None | False | None | False | 112976.25 | 0 | 4009767 | 155219 | None | CODE20.44.2 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm | Each | 3547.0 | 3547.0 | 2.0 | False | None | None | False | None | False | 7094.0 | 0 | 4009768 | 155219 | None | CODE11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc | Kg | 183.0 | 183.0 | 108.36 | False | None | None | False | None | False | 19829.88 | 0 | 4009769 | 155219 | None | CODE11.44 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete | Sqm | 4345.0 | 4345.0 | 5.27 | False | None | None | False | None | False | 22898.15 | 0 | 4009770 | 155219 | None | CODE12.86 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock | Sqm | 5390.0 | 5390.0 | 10.8 | False | None | None | False | None | False | 58212.0 | 0 | 4009771 | 155219 | None | CODE13.34 | Providing and placing on terrace(at all floor levels) polyethylene water storage tanks as per IS 12701 marked with cover and suitable locking arrangements and making necessory holes for inlet, outlet and over flow pipes, but without fittings and and base support for tank | l | 9.0 | 9.0 | 1000.0 | False | None | None | False | None | False | 9000.0 | 0 | 4009772 | 155219 | None | CODE13.50.2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | m | 172.0 | 172.0 | 80.0 | False | None | None | False | None | False | 13760.0 | 0 | 4009773 | 155219 | None | CODE13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal dia Pipes | m | 386.0 | 386.0 | 30.0 | False | None | None | False | None | False | 11580.0 | 0 | 4009774 | 155219 | None | CODE13.50.9 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal dia Pipes | m | 930.0 | 930.0 | 20.0 | False | None | None | False | None | False | 18600.0 | 0 | 4009775 | 155219 | None | CODE9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification | Sqm | 932.0 | 932.0 | 3.24 | False | None | None | False | None | False | 3019.68 | 0 | 4009776 | 155219 | None | CODE8.8.II | Supplying and erection of RCC rings for well steining of 0.30 mt depth,1.5 m dia using M-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well etc complete as per specification | Each | 1577.96 | 1577.96 | 5.0 | False | None | None | False | None | False | 7889.8 | 0 | 4009777 | 155219 | None | CODE12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges | m | 2847.0 | 2847.0 | 2.7 | False | None | None | False | None | False | 7686.9 | 0 | 4009778 | 155219 | None | CODE12.86 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door
frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge | Sqm | 475.0 | 475.0 | 10.2 | False | None | None | False | None | False | 4845.0 | 0 | 4009779 | 155219 | None | CODE11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 138.0 | 138.0 | 144.9 | False | None | None | False | None | False | 19996.2 | 0 | 4009780 | 155219 | None | CODE10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1106.0 | 1106.0 | 131.52 | False | None | None | False | None | False | 145461.12 | 0 | 4009781 | 155219 | None | CODE1.3.1 | Supplying heavy gauge PVC Conduit Pipe ….dia…..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | m | 56.0 | 56.0 | 180.0 | False | None | None | False | None | False | 10080.0 | 0 | 4009782 | 155219 | None | CODE1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, necessary masonry patch work complete. 10x7x3 (254x178x76mm) | Each | 87.0 | 87.0 | 8.0 | False | None | None | False | None | False | 696.0 | 0 | 4009783 | 155219 | None | CODE1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, necessary masonry patch work complete. 8x6x3 (203x152x76mm) | Each | 73.0 | 73.0 | 8.0 | False | None | None | False | None | False | 584.0 | 0 | 4009784 | 155219 | None | CODE1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, necessary masonry patch work complete. 4x4x3 (101x101x76mm) | Each | 68.0 | 68.0 | 8.0 | False | None | None | False | None | False | 544.0 | 0 | 4009785 | 155219 | None | CODE2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.) Short point up to 3Mtr from tapping point to out let via switch | Each | 174.0 | 174.0 | 6.0 | False | None | None | False | None | False | 1044.0 | 0 | 4009786 | 155219 | None | CODE2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose lenght in a woo PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch DO-- Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Each | 245.0 | 245.0 | 12.0 | False | None | None | False | None | False | 2940.0 | 0 | 4009787 | 155219 | None | CODE2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood PVC round block. complete for each outlet.) Short point up to 3Mtr from tapping point to out let via switch DO Lang point above 6Mtr up to 10Mtr from tapping point to out let via switch | Each | 363.0 | 363.0 | 12.0 | False | None | None | False | None | False | 4356.0 | 0 | 4009788 | 155219 | None | CODE2.5.2 | Wiring for lighting Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. ) GTP of GROUP a 1.5 sqmm | m | 18.6 | 18.6 | 300.0 | False | None | None | False | None | False | 5580.0 | 0 | 4009789 | 155219 | None | CODE2.5.2 | Wiring for lighting Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. GTP of GROUP do 2.5 sqmm (2.5.3) | m | 29.2 | 29.2 | 1100.0 | False | None | None | False | None | False | 32120.0 | 0 | 4009790 | 155219 | None | CODE2.5.2 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. GTP of GROUP do 4 sqmm | m | 42.1 | 42.1 | 700.0 | False | None | None | False | None | False | 29470.0 | 0 | 4009791 | 155219 | None | CODE3.7.4 | Supplying and fixing of modular switch Socket stepped electronic fan regulator dimmer telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Stepped Fan Regulator. | Each | 286.0 | 286.0 | 20.0 | False | None | None | False | None | False | 5720.0 | 0 | 4009792 | 155219 | None | CODE9.3 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48 Sweep (1200mm) Regular model | Each | 2376.0 | 2376.0 | 5.0 | False | None | None | False | None | False | 11880.0 | 0 | 4009793 | 155219 | None | CODE17.7 | Fixing all types and all capacities of fluorescent False ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 230.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall ceiling Rafter Girders | Each | 98.0 | 98.0 | 15.0 | False | None | None | False | None | False | 1470.0 | 0 |
|