1726558652000 | 0 | None | None | Buildings | Construction of Sheet Roop top for leakge in Indira Canteen building near Kavoor Pumphouse in MCC limits | 744027.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4013550 | 155456 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth(Page No. 8 Item No.1.15.1 COMMON SR 2023-24VOLUME-1 ). | Cum | 406.56 | 406.56 | 3.43 | False | None | None | False | None | False | 1394.5008 | 0 | 4013551 | 155456 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.1.6 common SR 2023-24 VOLUME-1 ). | Cum | 6992.16 | 6992.16 | 3.43 | False | None | None | False | None | False | 23983.1088 | 0 | 4013552 | 155456 | None | code03 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Page no 82, item no 11.16.1,Buildings SR 2023-24 Volume-2 ). | Kg | 152.32 | 152.32 | 3645.84 | False | None | None | False | None | False | 555334.3488 | 0 | 4013553 | 155456 | None | code04 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( Page no 26, item no 7.38 Buildings SR 2023-24 Volume-2) | Sqm | 636.16 | 636.16 | 165.6 | False | None | None | False | None | False | 105348.096 | 0 | 4013554 | 155456 | None | code05 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges Plain(500-600) ( Page no 27, item no 7.39.1 ,Buildings SR 2023-24 Volume-2 ). | Rmtr | 505.12 | 505.12 | 27.5 | False | None | None | False | None | False | 13890.8 | 0 | 4013555 | 155456 | None | code06 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) ( Page no 27, item no 7.39.6 ,Buildings SR 2023-24 Volume-2 ). | Rmtr | 1202.88 | 1202.88 | 19.8 | False | None | None | False | None | False | 23817.024 | 0 | 4013556 | 155456 | None | code07 | Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes Conforming of IS13592 Type A inculding Jointing with seal ring Conforming of IS 5382 leaving 10mm gap for thermal Expension (I) single socketed Pipe 75mm diameter ( Page no125, item no 13.47,Buildings SR 2023-24 Volume-2 ). | Rmtr | 220.64 | 220.64 | 31.0 | False | None | None | False | None | False | 6839.84 | 0 | 4013557 | 155456 | None | code08 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 48, item no 8.40,,Buildings SR 2023-24 Volume-2 ). | Sqm | 128.8 | 128.8 | 104.19 | False | None | None | False | None | False | 13419.672 | 0 |
|