createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726218859406
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd395000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-10-2024 15:00:00
tenderQueryClose04-10-2024 15:30:00
technicalBidOpen19-10-2024 16:00:00
publishedDate18-09-2024 11:03:00
publishedByPostBWSSB_CE_KAVOM_BNG
publishedByUserKPE10921 - RAJSHEKAR A
bidValidityPeriod90
noOfCalls1
preBidMeetingDate04-10-2024 15:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonFiroz Pasaha
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8217467686
tenderSupplierListNone
tenderSchedule
createdTs1726218859434
version4
createdDateNone
modifiedDateNone
tenderNumberBWSSB/2024-25/BD/WORK_INDENT1019
titleWork of Construction of Quarters Building 2 Block of 06 Houses (G plus 2) at T.K.Halli
descriptionWork of Construction of Quarters Building 2 Block of 06 Houses (G plus 2) at T.K.Halli
categoryWORKS
categoryTextWorks
ecv26321976.07
deptNameBengaluru Water Supply And Sewerage Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5136
locationNameBWSSB Chief Engineer Kaveri (Operation and Maintenance) Bengaluru
provisionalAmount34500000.0
groupOverheadTotalNone
fileNumber82/2022
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17262188590000NoneNoneBuildingsWork of Construction of Quarters Building 2 Block of 06 Houses (G plus 2) at T.K.Halli26321976.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3999825154775NoneA01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all Kinds of soil upto 300mm depthCum95.095.0141.2FalseNoneNoneFalseNoneFalse13414.00
3999826154775NoneA02Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In all kinds of soil depth upto 3m. FOR stair case foundation, SUMP & Column FootingsCum102.0102.0512.0FalseNoneNoneFalseNoneFalse52224.00
3999827154775NoneA03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse BED CONCRETE for SUMP, Colum footings,Stair case foundations and flagging around the buildingCum5664.05664.0113.44FalseNoneNoneFalseNoneFalse642524.160
3999828154775NoneA04form work,centering and scoffolding for item no.3Cum169.92169.92113.44FalseNoneNoneFalseNoneFalse19275.72480
3999829154775NoneA05Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates. FOR stair case foundationCum6323.06323.02.78FalseNoneNoneFalseNoneFalse17577.940
3999830154775NoneA06form work,centering and scoffolding for item no.A05Cum189.69189.692.78FalseNoneNoneFalseNoneFalse527.33820
3999831154775NoneA07From ground to 1st floor including lift charges for Flight,Mid Landing slab,steps, specification same as item no A05Cum6386.236386.233.6FalseNoneNoneFalseNoneFalse22990.4280
3999832154775NoneA08form work,centering and scoffolding for above itemCum3193.123193.123.6FalseNoneNoneFalseNoneFalse11495.2320
3999833154775NoneA09From 1st floor to 2nd floorincluding lift charges for Flight,Mid Landing slab,steps,specification same as item no A05Cum6537.826537.823.6FalseNoneNoneFalseNoneFalse23536.1520
3999834154775NoneA10form work,centering and scoffolding for above itemCum3268.913268.913.6FalseNoneNoneFalseNoneFalse11768.0760
3999835154775NoneA11From 2nd floor to tarrace including lift charges for Flight,Mid Landing slab,steps specification same as item no A05Cum6512.696512.693.6FalseNoneNoneFalseNoneFalse23445.6840
3999836154775NoneA12form work,centering and scoffolding for above itemCum3256.353256.353.6FalseNoneNoneFalseNoneFalse11722.860
3999837154775NoneA13From ground to 1st floor including lift chargesfor LINTELS,for 100mm thick walls and CILLS specification same as item no A05Cum6386.236386.235.04FalseNoneNoneFalseNoneFalse32186.59920
3999838154775NoneA14form work,centering and scoffolding for above itemCum3831.743831.745.04FalseNoneNoneFalseNoneFalse19311.96960
3999839154775NoneA15From 1st floor to 2nd floor including lift chargesfor LINTELS,for 100mm thick walls and CILLS specification same as item no A05Cum6449.466449.465.04FalseNoneNoneFalseNoneFalse32505.27840
3999840154775NoneA16form work,centering and scoffolding for above itemCum3869.683869.685.04FalseNoneNoneFalseNoneFalse19503.18720
3999841154775NoneA17From 2nd floor to tarrace including lift charges for LINTELS,for 100mm thick walls and CILLS specification same as item no A05Cum6512.696512.695.04FalseNoneNoneFalseNoneFalse32823.95760
3999842154775NoneA18form work,centering and scoffolding for above itemCum3907.613907.615.04FalseNoneNoneFalseNoneFalse19694.35440
3999843154775NoneA19Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates FOR Column Footings, PEDESTALS ,COLUMS BELOW GROUND LEVEL & SUMPCum6336.06336.099.26FalseNoneNoneFalseNoneFalse628911.360
3999844154775NoneA20form work,centering and scoffolding for above itemCum190.08190.0899.26FalseNoneNoneFalseNoneFalse18867.34080
3999845154775NoneA21FOR Ground floor Column specification same as item no A19Cum6299.06299.08.26FalseNoneNoneFalseNoneFalse52029.740
3999846154775NoneA22form work,centering and scoffolding for above itemCum4409.34409.38.26FalseNoneNoneFalseNoneFalse36420.8180
3999847154775NoneA23FOR 1sr Floor Column including lift charges specification same as item no A19Cum6399.366399.368.26FalseNoneNoneFalseNoneFalse52858.71360
3999848154775NoneA24form work,centering and scoffolding for above item and including staging for formworkCum5247.485247.488.26FalseNoneNoneFalseNoneFalse43344.18480
3999849154775NoneA25FOR 2nd Floor Column including lift charges specification same as item no A19Cum6462.726462.728.26FalseNoneNoneFalseNoneFalse53382.06720
3999850154775NoneA26form work ,centering and scoffolding for above item and including staging for formworkCum5299.435299.438.26FalseNoneNoneFalseNoneFalse43773.29180
3999851154775NoneA27FOR Terrace Floor Column including lift charges specification same as item no A19Cum6526.086526.082.754FalseNoneNoneFalseNoneFalse17972.824320
3999852154775NoneA28form work,centering and scoffolding for above item and including staging for formworkCum5351.395351.392.76FalseNoneNoneFalseNoneFalse14769.83640
3999853154775NoneA29Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates for plinth Beams and HR beams & HR slabCum6630.06630.026.62FalseNoneNoneFalseNoneFalse176490.60
3999854154775NoneA30form work,centering and scoffolding for above itemCum3978.03978.017.98FalseNoneNoneFalseNoneFalse71524.440
3999855154775NoneA31form work,centering and scoffolding for HR slabCum3315.03315.08.64FalseNoneNoneFalseNoneFalse28641.60
3999856154775NoneA32For ROOF Beams i.e sunken and stair beams for Ground Floor specification same as item no A29Cum6630.06630.015.02FalseNoneNoneFalseNoneFalse99582.60
3999857154775NoneA33form work,centering and scoffolding for above itemCum3978.03978.015.02FalseNoneNoneFalseNoneFalse59749.560
3999858154775NoneA34For ROOF Beams i.e sunken and stair beams for1st Floor including lift charges specification same as item no A29Cum6696.36696.315.02FalseNoneNoneFalseNoneFalse100578.4260
3999859154775NoneA35form work,centering and scoffolding for above item and including staging for formworkCum4821.344821.3415.02FalseNoneNoneFalseNoneFalse72416.52680
3999860154775NoneA36For ROOF Beams for i.e sunken and stair beams 2nd Floor including lift charges specification same as item no A29Cum6762.66762.615.02FalseNoneNoneFalseNoneFalse101574.2520
3999861154775NoneA37form work,centering and scoffolding for above item and including staging for formworkCum4869.074869.0715.02FalseNoneNoneFalseNoneFalse73133.43140
3999862154775NoneA38For ROOF SLABS i.e Floor,Utility-1&2 Front balcony and stair case landing slab s for Ground Floor specification same as item no A29Cum6630.06630.054.64FalseNoneNoneFalseNoneFalse362263.20
3999863154775NoneA39form work,centering and scoffolding for above itemCum3315.03315.054.64FalseNoneNoneFalseNoneFalse181131.60
3999864154775NoneA40For ROOF SLABS i.e Floor,Utility-1&2 Front balcony and stair case landing slab for1st Floor including lift charges specification same as item no A29Cum6696.36696.354.64FalseNoneNoneFalseNoneFalse365885.8320
3999865154775NoneA41form work,centering and scoffolding for above item and including staging for formworkCum4151.714151.7154.64FalseNoneNoneFalseNoneFalse226849.43440
3999866154775NoneA42For ROOF SLABS i.e Floor,Utility-1&2 Front balcony and stair case landing slab for 2nd Floor including lift charges specification same as item no A29Cum6762.66762.654.64FalseNoneNoneFalseNoneFalse369508.4640
3999867154775NoneA43form work,centering and scoffolding for above item and including staging for formworkCum4192.814192.8154.64FalseNoneNoneFalseNoneFalse229095.13840
3999868154775NoneA44Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) FOR SSM FOUNDATIONCum6389.06389.0113.26FalseNoneNoneFalseNoneFalse723618.140
3999869154775NoneA45Refilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum160.0160.0317.46FalseNoneNoneFalseNoneFalse50793.60
3999870154775NoneA46Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FOR WALLS OF GROUND FLOOR -external wallsSqm1310.01310.0335.8FalseNoneNoneFalseNoneFalse439898.00
3999871154775NoneA47FOR 1nd Floor Walls including lift charges specification same as item no A46Sqm1323.11323.1335.8FalseNoneNoneFalseNoneFalse444296.980
3999872154775NoneA48FOR 2nd Floor walls including lift charges specification same as item no A46Sqm1336.21336.2335.8FalseNoneNoneFalseNoneFalse448695.960
3999873154775NoneA49FOR tarrace HR & Parapet Walls including lift charges specification same as item no A46Sqm1349.31349.3185.0FalseNoneNoneFalseNoneFalse249620.50
3999874154775NoneA50Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications FOR WALLS OF GROUND FLOOR-internal wallsSqm1104.01104.0248.6FalseNoneNoneFalseNoneFalse274454.40
3999875154775NoneA51FOR 1nd Floor Walls including lift charges specification same as item no A50Sqm1115.041115.04248.6FalseNoneNoneFalseNoneFalse277198.9440
3999876154775NoneA52FOR 2nd Floor walls including lift charges specification same as item no A50Sqm1126.081126.08248.6FalseNoneNoneFalseNoneFalse279943.4880
3999877154775NoneA53Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates for GROUND FLOOR CANOPY, CHEJJA AND OTHERS FOR WINDOWSCum6630.06630.01.08FalseNoneNoneFalseNoneFalse7160.40
3999878154775NoneA54form work,centering and scoffolding for above itemCum2983.52983.51.08FalseNoneNoneFalseNoneFalse3222.180
3999879154775NoneA55FOR 1ST FLOOR with lift charges CANOPY, CHEJJA AND OTHERS specification same as item no A53Cum6696.36696.31.08FalseNoneNoneFalseNoneFalse7232.0040
3999880154775NoneA56form work,centering and scoffolding for above itemCum3013.343013.341.08FalseNoneNoneFalseNoneFalse3254.40720
3999881154775NoneA57FOR 2ND FLOOR with lift charges CANOPY, CHEJJA AND OTHERS specification same as item no A53Cum6763.266763.261.08FalseNoneNoneFalseNoneFalse7304.32080
3999882154775NoneA58form work,centering and scoffolding for above itemCum3043.473043.471.08FalseNoneNoneFalseNoneFalse3286.94760
3999883154775NoneA59Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates GROUND FLOOR CANOPY & CHEJJA FOR bedroom, bathrooms and kitchenCum6630.06630.02.32FalseNoneNoneFalseNoneFalse15381.60
3999884154775NoneA60form work,centering and scoffolding for above itemCum2983.52983.52.32FalseNoneNoneFalseNoneFalse6921.720
3999885154775NoneA61FOR 1st FLOOR CANOPY & CHEJJA FOR bedroom, bathrooms and kitchen including lift charges specification same as item no A59Cum6696.36696.32.31FalseNoneNoneFalseNoneFalse15468.4530
3999886154775NoneA62form work,centering and scoffolding for above itemCum3013.343013.342.32FalseNoneNoneFalseNoneFalse6990.94880
3999887154775NoneA63FOR 1st FLOOR CANOPY & CHEJJA FOR bedroom, bathrooms and kitchen including lift charges specification same as item no A59Cum6763.266763.262.31FalseNoneNoneFalseNoneFalse15623.13060
3999888154775NoneA64form work,centering and scoffolding for above itemCum3043.473043.472.32FalseNoneNoneFalseNoneFalse7060.85040
3999889154775NoneA65Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications for GROUND FLOOR DOORSCum138074.0138074.01.32FalseNoneNoneFalseNoneFalse182257.680
3999890154775NoneA66for 1ST FLOOR DOORS with lift charges specification same as item no A65Cum139454.74139454.741.32FalseNoneNoneFalseNoneFalse184080.25680
3999891154775NoneA67for 2ND FLOOR DOORS with lift charges specification same as item no A65Cum140849.29140849.291.32FalseNoneNoneFalseNoneFalse185921.06280
3999892154775NoneA68Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) for GROUND FLOOR DOORSSqm6150.06150.031.92FalseNoneNoneFalseNoneFalse196308.00
3999893154775NoneA69for 1ST FLOOR DOORS with lift charges specification same as item no A68Sqm6211.56211.531.92FalseNoneNoneFalseNoneFalse198271.080
3999894154775NoneA70for 2ND FLOOR DOORS with lift charges specification same as item no A68Sqm6273.626273.6231.92FalseNoneNoneFalseNoneFalse200253.95040
3999895154775NoneA71Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelam FOR D2 DOORSqm2366.02366.037.8FalseNoneNoneFalseNoneFalse89434.80
3999896154775NoneA72Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.GRILL WORK FOR WINDOWS AND VENTILATORS FOR GROUND FLOORKgs183.0183.0962.22FalseNoneNoneFalseNoneFalse176086.260
3999897154775NoneA73GRILL WORK FOR WINDOWS AND VENTILATORS FOR 1ST FLOOR with lift charges specification same as item no A72Kgs184.83184.83962.22FalseNoneNoneFalseNoneFalse177847.12260
3999898154775NoneA74GRILL WORK FOR WINDOWS AND VENTILATORS FOR 2ND FLOOR with lift charges specification same as item no A72Kgs186.66186.66962.22FalseNoneNoneFalseNoneFalse179607.98520
3999899154775NoneA75Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FOR STAIRCASE RAILING AND BALCONY FRONT RAILING FOR GROUND FLOORKgs183.0183.0287.14FalseNoneNoneFalseNoneFalse52546.620
3999900154775NoneA76FOR STAIRCASE RAILING AND BALCONY FRONT RAILING FOR 1ST FLOOR with lift charges specification same as item no A75Kgs184.47184.47287.14FalseNoneNoneFalseNoneFalse52968.71580
3999901154775NoneA77FOR STAIRCASE RAILING AND BALCONY FRONT RAILING FOR 2ND FLOOR with lift charges specification same as item no A75Kgs185.94185.94287.14FalseNoneNoneFalseNoneFalse53390.81160
3999902154775NoneA78Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer-in- charge-EXTERNAL WALLS FOR GROUND FLOORSqm354.0354.0648.72FalseNoneNoneFalseNoneFalse229646.880
3999903154775NoneA79FIRST FLOOR with lift charges- EXTERNAL WALLSspecification same as item no A78Sqm357.54357.54648.72FalseNoneNoneFalseNoneFalse231943.34880
3999904154775NoneA80SECOND FLOOR with lift charges- EXTERNAL WALLSspecification same as item no A78Sqm364.69364.69648.72FalseNoneNoneFalseNoneFalse236581.69680
3999905154775NoneA81FOR TERRACE-PARAPET WALL, HR WALLS AND CEILING PLASTERING specification same as item no A78Sqm316.27316.27574.4FalseNoneNoneFalseNoneFalse181665.4880
3999906154775NoneA82Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -Internal walls for ground floorSqm295.0295.0616.72FalseNoneNoneFalseNoneFalse181932.40
3999907154775NoneA83FIRST FLOOR with lift charges--INTERNAL WALLS specification same as item no A82Sqm297.95297.95616.72FalseNoneNoneFalseNoneFalse183751.7240
3999908154775NoneA84SECOND FLOOR with lift charges--INTERNAL WALLS specification same as item no A82Sqm300.9300.9616.72FalseNoneNoneFalseNoneFalse185571.0480
3999909154775NoneA85Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per pecifications and as per directions of Engineer-in-charge-ROUGH PLASTERING-STAIR CASE, WALLS OF TOILETS , KITCHEN FOR GROUND FLOORSqm349.0349.0218.28FalseNoneNoneFalseNoneFalse76179.720
3999910154775NoneA86FIRST FLOOR with lift charges--ROUGH PLASTERING -STAIR CASE, WALLS OF TOILETS , KITCHEN specification same as item no A85Sqm352.49352.49218.28FalseNoneNoneFalseNoneFalse76941.51720
3999911154775NoneA872ND FLOOR with lift charges--ROUGH PLASTERING -STAIR CASE, WALLS OF TOILETS , KITCHEN specification same as item no A85Sqm355.98355.98218.28FalseNoneNoneFalseNoneFalse77703.31440
3999912154775NoneA88Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.INTERNAL AND EXTERNAL CIELING PLASTERING FOR GROUND FLOORSqm100.0100.0909.9FalseNoneNoneFalseNoneFalse90990.00
3999913154775NoneA891ND FLOOR with lift charges-INTERNAL AND EXTERNAL CIELING PLASTERING specification same as item no A88Sqm100.83100.83909.9FalseNoneNoneFalseNoneFalse91745.2170
3999914154775NoneA902ND FLOOR with lift charges-INTERNAL AND EXTERNAL CIELING PLASTERING specification same as item no A88Sqm101.66101.66909.9FalseNoneNoneFalseNoneFalse92500.4340
3999915154775NoneA91Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer in-charge.FOR GROUND FLOOR INSIDE AND OUTSIDE PLASTERINGSqm26.026.0909.9FalseNoneNoneFalseNoneFalse23657.40
3999916154775NoneA92FOR 1ST FLOOR INSIDE AND OUTSIDE PLASTERING with lift charges specification same as item no A91Sqm26.2626.26909.9FalseNoneNoneFalseNoneFalse23893.9740
3999917154775NoneA93FOR 2ND FLOOR INSIDE AND OUTSIDE PLASTERING with lift charges specification same as item no A91Sqm26.5226.52909.9FalseNoneNoneFalseNoneFalse24130.5480
3999918154775NoneA94Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry completeSqm451.0451.0112.0FalseNoneNoneFalseNoneFalse50512.00
3999919154775NoneA95Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm FOR GROUND FLOORSqm1326.01326.0236.38FalseNoneNoneFalseNoneFalse313439.880
3999920154775NoneA96FOR 1ST FLOOR with lift charges specifications same as item no A95Sqm1339.261339.26236.38FalseNoneNoneFalseNoneFalse316574.27880
3999921154775NoneA97FOR 2nd FLOOR with lift charges specifications same as item no A95Sqm1352.521352.52236.38FalseNoneNoneFalseNoneFalse319708.67760
3999922154775NoneA98Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. FOR GROUND FLOORSqm932.0932.059.92FalseNoneNoneFalseNoneFalse55845.440
3999923154775NoneA99FOR 1ST FLOOR with lift charges specifications same as item no A98Sqm941.32941.3259.92FalseNoneNoneFalseNoneFalse56403.89440
3999924154775NoneA100FOR 2ND FLOOR with lift charges specifications same as item no A98Sqm950.64950.6459.92FalseNoneNoneFalseNoneFalse56962.34880
3999925154775NoneA101Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete FOR GROUND FLOOR FOR TOILETSSqm1076.01076.025.7FalseNoneNoneFalseNoneFalse27653.20
3999926154775NoneA102FOR 1ST FLOOR with lift charges specifications same as item no A101Sqm1086.761086.7625.7FalseNoneNoneFalseNoneFalse27929.7320
3999927154775NoneA103FOR 2ND FLOOR with lift charges specifications same as item no A101Sqm1076.01076.025.7FalseNoneNoneFalseNoneFalse27653.20
3999928154775NoneA104Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3kg perm2 including pointing in white cement mixed with pigment of matching shade complete.FOR GROUND FLOOR FOR TOILETSSqm1106.01106.0112.22FalseNoneNoneFalseNoneFalse124115.320
3999929154775NoneA105FOR 1ST FLOOR with lift charges specifications same as item no A104Sqm1117.061117.06112.22FalseNoneNoneFalseNoneFalse125356.47320
3999930154775NoneA106FOR 2ND FLOOR with lift charges specifications same as item no A104Sqm1128.121128.12112.22FalseNoneNoneFalseNoneFalse126597.62640
3999931154775NoneA107Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FOR GROUND FLOORSqm89.089.0648.72FalseNoneNoneFalseNoneFalse57736.080
3999932154775NoneA108FOR 1ST FLOOR with lift charges specifications same as item no A104Sqm89.8989.89648.72FalseNoneNoneFalseNoneFalse58313.44080
3999933154775NoneA109FOR 2ND FLOOR with lift charges specifications same as item no A104Sqm90.7890.78648.72FalseNoneNoneFalseNoneFalse58890.80160
3999934154775NoneA110For PARAPET and HR walls with lift charges specifications same as item no A104Sqm91.6791.67574.4FalseNoneNoneFalseNoneFalse52655.2480
3999935154775NoneA111Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. internal wall for ground floorSqm137.0137.0909.9FalseNoneNoneFalseNoneFalse124656.30
3999936154775NoneA112FOR 1ST FLOOR - ceiling painting with lift charges specifications same as item no A104Sqm138.37138.37293.18FalseNoneNoneFalseNoneFalse40567.31660
3999937154775NoneA113FOR 2ND FLOOR ceiling painting with lift charges specifications same as item no A104Sqm139.74139.74293.18FalseNoneNoneFalseNoneFalse40968.97320
3999938154775NoneA114Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm58.058.0133.56FalseNoneNoneFalseNoneFalse7746.480
3999939154775NoneA115Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm53.053.0133.56FalseNoneNoneFalseNoneFalse7078.680
3999940154775NoneA116Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm115.0115.0292.68FalseNoneNoneFalseNoneFalse33658.20
3999941154775NoneA117Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst89457.089457.066.3FalseNoneNoneFalseNoneFalse5930999.10
3999942154775NoneA118Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In chargeSqm817.0817.0354.6FalseNoneNoneFalseNoneFalse289708.20
3999943154775NoneA119Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 for rGROUND FLOORSqm4006.04006.015.38FalseNoneNoneFalseNoneFalse61612.280
3999944154775NoneA120FOR 1ST FLOOR with lift charges specifications same as item no A119Sqm4046.064046.0615.38FalseNoneNoneFalseNoneFalse62228.40280
3999945154775NoneA121FOR 2ND FLOOR with lift charges specifications same as item no A119Sqm4086.124086.1215.38FalseNoneNoneFalseNoneFalse62844.52560
3999946154775NoneA122Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications for rGROUND FLOORSqm1171.01171.045.82FalseNoneNoneFalseNoneFalse53655.220
3999947154775NoneA123FOR 1ST FLOOR with lift charges specifications same as item no A122Sqm1182.711182.7145.82FalseNoneNoneFalseNoneFalse54191.77220
3999948154775NoneA124FOR 2ND FLOOR with lift charges specifications same as item no A122Sqm1194.421194.4245.82FalseNoneNoneFalseNoneFalse54728.32440
3999949154775NoneA125Refilling available excavated earth around in enches/pipelines, cables, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum160.0160.0427.5FalseNoneNoneFalseNoneFalse68400.00
3999950154775NoneA126Water and Sanitary works Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant IS/ISO/DIN/BIS codes and also testing of joints complete as per direction of Engineer-In- Charge etc. complete PN - 16 Pipe, SDR 7.4 -16 mm ODm190.0190.0160.0FalseNoneNoneFalseNoneFalse30400.00
3999951154775NoneA127PN - 16 Pipe, SDR 7.4 -20 mm OD specifications same as item no A126m205.0205.0700.0FalseNoneNoneFalseNoneFalse143500.00
3999952154775NoneA128PN - 16 Pipe, SDR 7.4 -25 mm OD specifications same as item no A127m254.0254.0600.0FalseNoneNoneFalseNoneFalse152400.00
3999953154775NoneA129PN - 16 Pipe, SDR 7.4 -32 mm OD specifications same as item no A128m345.0345.0800.0FalseNoneNoneFalseNoneFalse276000.00
3999954154775NoneA130Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM (Copper alloy) Gate valvesEach888.0888.012.0FalseNoneNoneFalseNoneFalse10656.00
3999955154775NoneA131providing and fixing brass stop cock of approved quality 15 mm nominal boreNos299.0299.024.0FalseNoneNoneFalseNoneFalse7176.00
3999956154775NoneA132Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNos332.0332.012.0FalseNoneNoneFalseNoneFalse3984.00
3999957154775NoneA133Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos305.0305.060.0FalseNoneNoneFalseNoneFalse18300.00
3999958154775NoneA134Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal boreNos91.091.0120.0FalseNoneNoneFalseNoneFalse10920.00
3999959154775NoneA135Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation gre ater than400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm817.0817.077.1FalseNoneNoneFalseNoneFalse62990.70
3999960154775NoneA136providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :: 510x1040 mm bowl depth 250 mmNos5618.05618.012.0FalseNoneNoneFalseNoneFalse67416.00
3999961154775NoneA137Interal Sanitary connection Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. Vol-II SR 2023-24 P-137 I-14.35.1Nos8632.08632.012.0FalseNoneNoneFalseNoneFalse103584.00
3999962154775NoneA138Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mmEach3547.03547.012.0FalseNoneNoneFalseNoneFalse42564.00
3999963154775NoneA139Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tapsEach2866.02866.036.0FalseNoneNoneFalseNoneFalse103176.00
3999964154775NoneA140Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.Each1423.01423.036.0FalseNoneNoneFalseNoneFalse51228.00
3999965154775NoneA141Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC 63mm dia,6kg/sqcm & class3m161.0161.0260.0FalseNoneNoneFalseNoneFalse41860.00
3999966154775NoneA142KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 (1cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2017.02017.07.76FalseNoneNoneFalseNoneFalse15651.920
3999967154775NoneA143Providing and fixing 100mm sand cast iron grating for gully trapNos47.047.048.0FalseNoneNoneFalseNoneFalse2256.00
3999968154775NoneA144Providing and fixing PTMT grating of approved quality and colour 100mm nominal dia.Nos41.041.048.0FalseNoneNoneFalseNoneFalse1968.00
3999969154775NoneA145Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameterNos257.0257.024.0FalseNoneNoneFalseNoneFalse6168.00
3999970154775NoneA146External Sanitary Connection Supplying PVC ring tite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC 110mm dia,6kg/sqcm & class3Mtr411.0411.0500.0FalseNoneNoneFalseNoneFalse205500.00
3999971154775NoneA147Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC 140mm dia,6kg/sqcm & class3Mtr584.0584.0400.0FalseNoneNoneFalseNoneFalse233600.00
3999972154775NoneA148Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum484.0484.0200.0FalseNoneNoneFalseNoneFalse96800.00
3999973154775NoneA149Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5454.05454.024.0FalseNoneNoneFalseNoneFalse130896.00
3999974154775NoneA150Electrification Works Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm66.066.04000.0FalseNoneNoneFalseNoneFalse264000.00
3999975154775NoneA15125mm dia 2mm thick Specification same item no.A150m78.078.01400.0FalseNoneNoneFalseNoneFalse109200.00
3999976154775NoneA152Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20mm dia 2mm thickm68.068.02000.0FalseNoneNoneFalseNoneFalse136000.00
3999977154775NoneA15325mm dia 2mm thick Specification same item no.A152m79.079.01000.0FalseNoneNoneFalseNoneFalse79000.00
3999978154775NoneA154Supplying and fixing PVC/metal conduit accessories.a)19/20mm special type junction boxEach49.049.0340.0FalseNoneNoneFalseNoneFalse16660.00
3999979154775NoneA155b)25mm deep junction box Specification same item no.A154Each56.056.0150.0FalseNoneNoneFalseNoneFalse8400.00
3999980154775NoneA156Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a)1-2WayEach138.0138.0110.0FalseNoneNoneFalseNoneFalse15180.00
3999981154775NoneA157b)4-5WaySpecification same item no.A156Each177.0177.064.0FalseNoneNoneFalseNoneFalse11328.00
3999982154775NoneA158c)6Way Specification same item no.A156Each220.0220.072.0FalseNoneNoneFalseNoneFalse15840.00
3999983154775NoneA159d)8Way Specification same item no.A156Each261.0261.080.0FalseNoneNoneFalseNoneFalse20880.00
3999984154775NoneA160e)10-12Way Specification same item no.A156Each319.0319.044.0FalseNoneNoneFalseNoneFalse14036.00
3999985154775NoneA161Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete of each outlet. a) Short point up to 3Mtr from tapping point to out let via switchPoint285.0285.0156.0FalseNoneNoneFalseNoneFalse44460.00
3999986154775NoneA162b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint394.0394.0260.0FalseNoneNoneFalseNoneFalse102440.00
3999987154775NoneA163c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint570.0570.0640.0FalseNoneNoneFalseNoneFalse364800.00
3999988154775NoneA164Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group A 1-2 moduleEach137.0137.096.0FalseNoneNoneFalseNoneFalse13152.00
3999989154775NoneA1654 moduleEach175.0175.096.0FalseNoneNoneFalseNoneFalse16800.00
3999990154775NoneA1666 moduleEach234.0234.048.0FalseNoneNoneFalseNoneFalse11232.00
3999991154775NoneA1678 moduleEach284.0284.048.0FalseNoneNoneFalseNoneFalse13632.00
3999992154775NoneA16810 module 10-12 moduleEach344.0344.024.0FalseNoneNoneFalseNoneFalse8256.00
3999993154775NoneA169Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. a) 6 Amps SP Switch.Nos55.055.01600.0FalseNoneNoneFalseNoneFalse88000.00
3999994154775NoneA170b) 6 Amps two way switch.Nos70.070.0150.0FalseNoneNoneFalseNoneFalse10500.00
3999995154775NoneA171d) Electronic stepped regulatorNos281.0281.036.0FalseNoneNoneFalseNoneFalse10116.00
3999996154775NoneA172g) 16 Amps SP switchNos131.0131.096.0FalseNoneNoneFalseNoneFalse12576.00
3999997154775NoneA173c) 6 Amps 3 way 5 pin socket.Nos70.070.0500.0FalseNoneNoneFalseNoneFalse35000.00
3999998154775NoneA174i) 32 Amps bakelite DP switchNos232.0232.096.0FalseNoneNoneFalseNoneFalse22272.00
3999999154775NoneA175Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.a)25mmm35.035.0240.0FalseNoneNoneFalseNoneFalse8400.00
4000000154775NoneA176Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely a)25mmm22.022.048.0FalseNoneNoneFalseNoneFalse1056.00
4000001154775NoneA177Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote..a)Ding Dong bellNos246.0246.012.0FalseNoneNoneFalseNoneFalse2952.00
4000002154775NoneA178Supplying and fixing cast aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15 watts 230V CFL lamp as required a)Group ANos1078.01078.048.0FalseNoneNoneFalseNoneFalse51744.00
4000003154775NoneA179Supply box type fluorescent tube light fitting of 4'- 36/40 watts fluorescent tube fitting, made out of MS sheet and stove enameled with low loss open construction copper wound ferromagnetic ballast, starter, locking type brass contact holders mounted on double fold type sheet base fully wired for use o 230 volts AC supply including fluorescent tube (1x4'-36/40 watts)Nos300.0300.0140.0FalseNoneNoneFalseNoneFalse42000.00
4000004154775NoneA180Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach2984.02984.036.0FalseNoneNoneFalseNoneFalse107424.00
4000005154775NoneA181Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. a)12"sweep(300mm)Nos2969.02969.012.0FalseNoneNoneFalseNoneFalse35628.00
4000006154775NoneA182Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame..Nos707.0707.012.0FalseNoneNoneFalseNoneFalse8484.00
4000007154775NoneA183Supplying and fixing of shunt trip suitable for MCCB CBCTEach1703.01703.02.0FalseNoneNoneFalseNoneFalse3406.00
4000008154775NoneA184Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)Nos13230.013230.02.0FalseNoneNoneFalseNoneFalse26460.00
4000009154775NoneA185Supplying and fixing of class A (medium duty) GI pipe of wall thickness of not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 kv class (40mm)m335.0335.020.0FalseNoneNoneFalseNoneFalse6700.00
4000010154775NoneA186Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 kv class (metal only) 45mm diaEach194.0194.08.0FalseNoneNoneFalseNoneFalse1552.00
4000011154775NoneA187Supplying and making HT-XLPE/PILC heat shrinkable push on/resin cast UG cable termination suitable for 11/6.6 kv HT cable complete (outdoor HT kit 3x95sqmm)Kit9855.09855.04.0FalseNoneNoneFalseNoneFalse39420.00
4000012154775NoneA188Supplying and making HT-XLPE/PILC heat shrinkable push on/resin cast UG cable termination suitable for 11/6.6 kv HT cable complete (indoorr HT kit 3x95sqmm)Kit8164.08164.04.0FalseNoneNoneFalseNoneFalse32656.00
4000013154775NoneA189Supplying and making HT-XLPE/PILC heat shrinkable push on/resin cast UG cable jointing kit suitable for 11/6.6 kv HT cable complete (HT kit 3x95sqmm) a)Group AKit18487.018487.02.0FalseNoneNoneFalseNoneFalse36974.00
4000014154775NoneA190Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multistrand Copper wire with low resistance conductor single core cable in open or concealed system of wiring. b) 1.5 sqmmm20.520.52200.0FalseNoneNoneFalseNoneFalse45100.00
4000015154775NoneA191c) 2.5 sqmmm32.032.06400.0FalseNoneNoneFalseNoneFalse204800.00
4000016154775NoneA192d) 4 sqmmm45.045.05200.0FalseNoneNoneFalseNoneFalse234000.00
4000017154775NoneA193Extra for supplying 4mm thick white plastic plate and covering for junction boxes or size ……mm conduit using necessary machine screws.a)80mmNos9.09.0800.0FalseNoneNoneFalseNoneFalse7200.00
4000018154775NoneA194b)110mmNos11.011.0320.0FalseNoneNoneFalseNoneFalse3520.00
4000019154775NoneA1956Amps Lamps holderNos58.058.0976.0FalseNoneNoneFalseNoneFalse56608.00
4000020154775NoneA196Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. A)6-32 Amps SPEach415.0415.0160.0FalseNoneNoneFalseNoneFalse66400.00
4000021154775NoneA197Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release,Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .(Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation nbetween front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.Four pole C)200 Amps 36kA a)Group AEach21424.021424.04.0FalseNoneNoneFalseNoneFalse85696.00
4000022154775NoneA198Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo4256.04256.026.0FalseNoneNoneFalseNoneFalse110656.00
4000023154775NoneA199Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25*6 mmII.Copper Strip b)25x6mmNo128.0128.0240.0FalseNoneNoneFalseNoneFalse30720.00
4000024154775NoneA200Supplying of 1.1kv LT UG cable XLPE or heat resistant pvc insulated, pvc extruded inner sheath armoured UG LT cable as per IS-1554 part-1 or IS -7098 part-1,armouring strip thickness in average +5% resistivity 14ohms/kms(max) as per IS-3975.I.Class 'A' PVC Cable h) 3.5 core 70SqmmKm13954.913954.92.0FalseNoneNoneFalseNoneFalse27909.80
4000025154775NoneA201Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 25 Sq mm to 75 Sq mm I. In existing trench/duct, b)25sqmm to 75sqmmm15.515.5300.0FalseNoneNoneFalseNoneFalse4650.00
4000026154775NoneA202II.On wall/structure b)25sqmm to 75sqmmm35.035.0400.0FalseNoneNoneFalseNoneFalse14000.00
4000027154775NoneA203Digging of trench of 0.6m deep x 0.50 Mtr wide refilling the trench to the required ground level and consolidating etc., complete.b)In soil (hard)m102.0102.0600.0FalseNoneNoneFalseNoneFalse61200.00
4000028154775NoneA204HT CABLE - Group - A: Supplying and laying of high tension Dry Cure 3 core under ground XLPE (E) cable having stranded compact circular aluminum conductor, screened insulated, insulation screened with extruded semi conducting compound in combination with copper tape, core laid up inner sheathed of PVC tape GI flat strip armored and overall PVC sheathed confirm to IS 7098/11/85 with latest amendments.a)3Cx95sqmmRmtr1040.01040.0400.0FalseNoneNoneFalseNoneFalse416000.00
4000029154775NoneA205Supplying, fixing and wiring electronic 10 to 40Amps Electro Mechanical single phase energy meter Group A 5-20AmpsNos1150.01150.012.0FalseNoneNoneFalseNoneFalse13800.00
4000030154775NoneA206Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wiredEach5705.05705.04.0FalseNoneNoneFalseNoneFalse22820.00
4000031154775NoneA207Supplying and fixing LT cast iron pot heads suitable for 1.1kv class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc., 70sqmmEach622.0622.04.0FalseNoneNoneFalseNoneFalse2488.00
4000032154775NoneA208Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Group A - 6sqmmMtr19.019.04800.0FalseNoneNoneFalseNoneFalse91200.00
4000033154775NoneA209Group A - 1sqmmMtr92.092.0600.0FalseNoneNoneFalseNoneFalse55200.00
4000034154775NoneA210Supplying, fixing , wiring earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc., the pipe shall have 16 through holes of 12mm diaNos4256.04256.016.0FalseNoneNoneFalseNoneFalse68096.00
4000035154775NoneA211Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.200ltrEach46914.046914.012.0FalseNoneNoneFalseNoneFalse562968.00
4000036154775NoneA212Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following size 50 sqmm,long barrelNos60.060.030.0FalseNoneNoneFalseNoneFalse1800.00
4000037154775NoneA21370 sqmm,long barrelNos95.095.030.0FalseNoneNoneFalseNoneFalse2850.00
4000038154775NoneA214Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc., (GI wire-8 SWG) all terms and conditions as per tender documentMtr19.019.0146.0FalseNoneNoneFalseNoneFalse2774.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17262188600000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17262188600000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17262188600001NoneNoneELIGIBILITYBidder Shall quote item rate as exclusive of GSTNone
17262188600000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17262188600000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17262188800000NoneNoneELIGIBILITYAll terms and Conditions as per bid document onlyNone
17262189040000NoneNoneELIGIBILITYBidder Shall quote item rate as exclusive of GSTNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneeach Tenderer in its name should have in the last five financial years i.e. 2019-20 to 2023-24 d)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totaling Rs.21.46 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneeach Tenderer in its name should have in the last five financial years i.e. 2019-20 to 2023-24 c) The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totaling Rs.23.84Lakhs in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneeach Tenderer in its name should have in the last five financial years i.e. 2019-20 to 2023-24 a)As prime contractor, should have satisfactorily completed at least one Similar Contract such as work of Construction of Building of value not less than Rs.155.3 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneeach Tenderer in its name should have in the last five financial years i.e. 2019- 20 to 2023 -24 Executed in any one year, should have satisfactorily executed following minimum quantity of Works: 1.Earth work Excavation -400 m3 2Construction of Solid Concrete Block wall 1551 m2 3.Steel Reinforcement- 53 tons 4.Reinforced cement concrete -324m3Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTender Should have achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.621.2 lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Audited Annual Turnover, Balance sheet and P&L Statement
NoneNoneNoneNoneLiquid assets or availability of credit facilities of not less than Rs.77.65 Lakhs (Credit lines/ letter of credit/ certificates from Nationalized/schedule banks in India for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNone4)Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity is equals to (A X N X1.5 - B) is more than Rs. 310.6 lakhs Where, A is equals to Maximum value of civil engineering works executed in any one year during the last five years (updated to 2024 25 price level) taking into account the completed as well as works in progress. N is equals to Number of years prescribed for completion of the works for which tenders are invited is equals to1 B is equals to Value, at 2024 25 price level, of existing commitments and on-going works to be completed during the next 1 years (period of completion of the works for which Tenders are invited)OthersTender Bid Capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender Bid Capacity
NoneNoneNoneNoneForm of TenderOthersForm of Tender
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Form of tender with firm Letter Head and the format of Form of tender should be as per bid document.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Balanace sheetFalseTechnical Bid
Civil Contractor Registration Certificate Class-ITrueTechnical Bid
PAN, GST CertificatesFalseTechnical Bid
Profit and Loss StatementTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1726221070000
version0
createdDateNone
modifiedDateNone
blockNumberChief Engineer (Kaveri-O and M) Chamber, 6th floor, Cauvery Bhavan, K G Road, Bangalore-560009
streetNone
cityBangalore
stateKarnataka
pin560009
tenderRecallDTONone