4025114 | 156012 | None | PWD common SR 2023 -2024 Page no 5 item no 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
| Cum | 242.0 | 242.0 | 89.34 | False | None | None | False | None | False | 21620.28 | 0 |
4025115 | 156012 | None | PWD common SR 2023 -2024 Page no 15 item no 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates PWD common SR 2023 -2024 Page no 15 item no 2.1.2 | Cum | 5664.0 | 5664.0 | 22.76 | False | None | None | False | None | False | 128912.64 | 0 |
4025116 | 156012 | None | PWD common SR 2023 -2024 Page no 15 item no 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6287.0 | 6287.0 | 19.35 | False | None | None | False | None | False | 121653.45 | 0 |
4025117 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for columns footings | Cum | 188.61 | 188.61 | 14.51 | False | None | None | False | None | False | 2736.7311 | 0 |
4025118 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for Plinth Beam
| Cum | 3143.5 | 3143.5 | 4.84 | False | None | None | False | None | False | 15214.54 | 0 |
4025119 | 156012 | None | PWD building SR 2023 -2024 Page no 9 item no 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5611.0 | 5611.0 | 39.12 | False | None | None | False | None | False | 219502.32 | 0 |
4025120 | 156012 | None | PWD common SR 22023 -2024 Page no 16 item no 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6853.0 | 6853.0 | 30.34 | False | None | None | False | None | False | 207920.02 | 0 |
4025121 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for Columns
| Cum | 4797.1 | 4797.1 | 7.31 | False | None | None | False | None | False | 35066.801 | 0 |
4025122 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for lintels | Cum | 4111.8 | 4111.8 | 1.71 | False | None | None | False | None | False | 7031.178 | 0 |
4025123 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for Chajjaa
| Cum | 3083.85 | 3083.85 | 0.23 | False | None | None | False | None | False | 709.2855 | 0 |
4025124 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for Roof Beam | Cum | 4111.8 | 4111.8 | 3.6 | False | None | None | False | None | False | 14802.48 | 0 |
4025125 | 156012 | None | PWD common SR 2023 -2024 Vol-1 Page no 111 & 112 | For Additionalities for Formwork,Centring & Scaffolding for Slab
| Cum | 3426.5 | 3426.5 | 17.49 | False | None | None | False | None | False | 59929.485 | 0 |
4025126 | 156012 | None | PWD common SR 2023 -2024 Page no 7 item no 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 87.71 | False | None | None | False | None | False | 23330.86 | 0 |
4025127 | 156012 | None | PWD building SR 2023 -2024 Page no 13 item no 6.7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8211.0 | 8211.0 | 32.98 | False | None | None | False | None | False | 270798.78 | 0 |
4025128 | 156012 | None | PWD common SR 2023 -2024 Page no 15 item no 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 ( M 10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 1.71 | False | None | None | False | None | False | 10631.07 | 0 |
4025129 | 156012 | None | PWD building SR 2023 -2024 Page no 99 item no 12.5 | Providing Jungle wood such as Nerale, Neem wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications. | Cum | 44929.0 | 44929.0 | 0.392 | False | None | None | False | None | False | 17612.168 | 0 |
4025130 | 156012 | None | PWD building SR 2023 -2024 Page no 104 item no 12. | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Each | 1016.0 | 1016.0 | 2.0 | False | None | None | False | None | False | 2032.0 | 0 |
4025131 | 156012 | None | PWD building SR 2023 -2024 Page no 104 item no 12. | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Each | 773.0 | 773.0 | 6.0 | False | None | None | False | None | False | 4638.0 | 0 |
4025132 | 156012 | None | PWD building SR 2023 -2024 Page no 100 item no 12. | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures
"
| Sqm | 6576.0 | 6576.0 | 5.04 | False | None | None | False | None | False | 33143.04 | 0 |
4025133 | 156012 | None | PWD building SR 2023 -2024 Page no 101 item no 12. | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 7013.0 | 7013.0 | 10.8 | False | None | None | False | None | False | 75740.4 | 0 |
4025134 | 156012 | None | PWD building SR 2023 -2024 Page no 106 item no 12. | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mm | Each | 55.0 | 55.0 | 48.0 | False | None | None | False | None | False | 2640.0 | 0 |
4025135 | 156012 | None | PWD SR 2023 -2024 vol-2 Page no 69 it 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.
| Each | 60.0 | 60.0 | 36.0 | False | None | None | False | None | False | 2160.0 | 0 |
4025136 | 156012 | None | PWD building SR 2021 -2022 Page no 86 item no 11.3 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 168.0 | 168.0 | 226.8 | False | None | None | False | None | False | 38102.4 | 0 |
4025137 | 156012 | None | PWD SR 2023 -2024 Page no 18 item no 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations as per drawing and technical specification | Tonne | 89457.0 | 89457.0 | 3.31 | False | None | None | False | None | False | 296102.67 | 0 |
4025138 | 156012 | None | PWD SR 2023 -2024 Page no 41 item no 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 354.0 | 354.0 | 41.66 | False | None | None | False | None | False | 14747.64 | 0 |
4025139 | 156012 | None | PWD SR 2023 -2024 Page no 16 item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6630.0 | 6630.0 | 2.38 | False | None | None | False | None | False | 15779.4 | 0 |
4025140 | 156012 | None | PWD SR 2023 -2024 Page no 42 item no 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 349.0 | 349.0 | 387.86 | False | None | None | False | None | False | 135363.14 | 0 |
4025141 | 156012 | None | PWD SR 2023 -2024 Page no 41 item no 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
"
| Sqm | 312.0 | 312.0 | 128.5 | False | None | None | False | None | False | 40092.0 | 0 |
4025142 | 156012 | None | PWD SR 2023 -2024 vol-2 Page no 50 It 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge
| Sqm | 100.0 | 100.0 | 307.78 | False | None | None | False | None | False | 30778.0 | 0 |
4025143 | 156012 | None | PWD SR 2023 -2024 VOL-2 Pg No 84 It 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge.
| Kg | 138.0 | 138.0 | 85.05 | False | None | None | False | None | False | 11736.9 | 0 |
4025144 | 156012 | None | PWD SR 2023 -2024 Page no 149 it no 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 817.0 | 817.0 | 128.77 | False | None | None | False | None | False | 105205.09 | 0 |
4025145 | 156012 | None | PWD building SR 2023 -2024 Page no 64 item no 9.35 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1636.0 | 1636.0 | 139.96 | False | None | None | False | None | False | 228974.56 | 0 |
4025146 | 156012 | None | PWD SR 2023 -2024 Page no 125 item no 13.47 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conferming to IS :13592 type A Including Jointing with seal ring conferming to IS 5382 leaving to 10 mm gap for thermal expansion (i)Single socketed pipes 75 mm daimeter
| Mtr | 197.0 | 197.0 | 21.0 | False | None | None | False | None | False | 4137.0 | 0 |
4025147 | 156012 | None | PWD building SR 2023 -2024 Page no 55 item no 8.84 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 368.76 | False | None | None | False | None | False | 50520.12 | 0 |
4025148 | 156012 | None | PWD SR 2023 -2024 Page no 55 item no 8.84 | Providing wall black boards in 12 mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc. complete. | Each | 475.0 | 475.0 | 4.0 | False | None | None | False | None | False | 1900.0 | 0 |
4025149 | 156012 | None | PWD SR 2023 -2024 Page no 46 item no 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 178.0 | 178.0 | 245.56 | False | None | None | False | None | False | 43709.68 | 0 |
4025150 | 156012 | None | PWD SR 2023 -2024 Page no 47 item no 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer ofapproved brand and manufacture on wood work (hard and soft wood)including preparing the surface after thorougly cleaning oil, grease,dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge | Sqm | 53.0 | 53.0 | 35.64 | False | None | None | False | None | False | 1888.92 | 0 |
4025151 | 156012 | None | PWD building SR 2023 -2024 Page no 46 item no 8.33 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 138.0 | 138.0 | 35.64 | False | None | None | False | None | False | 4918.32 | 0 |
4025152 | 156012 | None | PWD Ele Vol-6 Part III SR 23-24 - It No- 1.2 Pg 2 | Suppling heavy gauge P V C Conduit pipe …. Mm dai … mm thick Confireming to I S 2509 with suitable size bends P V C Junction boxes ETC and running before concreting slab the conduite shouldbe tide to the reinforcement rod by using binding wires and pipe ends should be covered using P V C end enclosures run with 18 SWG GI fish wire wherever necessary | Mtr | 78.0 | 78.0 | 70.0 | False | None | None | False | None | False | 5460.0 | 0 |
4025153 | 156012 | None | PWD Ele-SR 2023-24 Pg-5, It 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box
| Point | 269.0 | 269.0 | 8.0 | False | None | None | False | None | False | 2152.0 | 0 |
4025154 | 156012 | None | PWD Ele-SR 2023-24 Pg-5, It 2.2.2 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
| Point | 379.0 | 379.0 | 3.0 | False | None | None | False | None | False | 1137.0 | 0 |
4025155 | 156012 | None | PWD Ele-SR 2023-2024 Pg-3, Item code 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. in Brick Masonry | Mtr | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
4025156 | 156012 | None | PWD Ele-SR 2023-2024 Pg-3, Item code 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm
| Mtr | 26.0 | 26.0 | 160.0 | False | None | None | False | None | False | 4160.0 | 0 |
4025157 | 156012 | None | PWD Ele-SR 2023-2024 Pg-3, It 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5sqmm
| Mtr | 42.0 | 42.0 | 100.0 | False | None | None | False | None | False | 4200.0 | 0 |
4025158 | 156012 | None | PWD Ele-SR 2023-2024 Pg-8, It 3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way . complete as per direction of engineer in charge.4-5 way | Each | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 |
4025159 | 156012 | None | PWD Ele-SR 2023-2024 Pg-8, Item code 3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6-8Way . complete as per direction of engineer in charge.8 way
| Each | 219.0 | 219.0 | 2.0 | False | None | None | False | None | False | 438.0 | 0 |
4025160 | 156012 | None | PWD Ele-SR 2022-2023,Item code 3.6.4 | Supplying and fixing of modular Stepped Fan Regulator.Stepped Fan Regulator Two Module
| Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 |
4025161 | 156012 | None | PWD Ele Vol-6 Part III SR 23-24 It No 13.12 pg 57 | Extra length of GI pipe of class B 19mm dia for down rod. (GI Pipe for Fan Down Rod)
| Each | 197.0 | 197.0 | 4.0 | False | None | None | False | None | False | 788.0 | 0 |
4025162 | 156012 | None | PWD Ele Vol-6 SR 23-24 -It No.6.3 Pg No 30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48"" Sweep (1200mm | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 |
4025163 | 156012 | None | ELE SR 2023-24 Pg-9 ,IT No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 12936 Amps 3 way Socket | Each | 171.0 | 171.0 | 12.0 | False | None | None | False | None | False | 2052.0 | 0 |
4025164 | 156012 | None | ELECTRICAL SR 2023-24 Pg-9 ITEM No 3.6.5 | Supplying and fixing of 400 Watts Dimmer | Each | 276.0 | 276.0 | 2.0 | False | None | None | False | None | False | 552.0 | 0 |
4025165 | 156012 | None | ELECTRICAL SR 2023-24 Pg-9 ITEM No 3.6.9 | Supplying and fixing of 32 Ams D P Switch | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 |
4025166 | 156012 | None | Ele Vol-6 Part III SR 23-24 - It 13.7.1 pg 56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (On wall / ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 10.0 | False | None | None | False | None | False | 1220.0 | 0 |
4025167 | 156012 | None | Ele Vol-6 SR 23-24 -Item No. - 5.18.9 PageNo. - 18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (50-63Amps TPN)
| Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
4025168 | 156012 | None | Ele Vol-6 SR 23-24 It No12.56 Page No 54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122 mm dia
| Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |
4025169 | 156012 | None | Elec SR - 2018-19 - It 6.18.3 Page No. 44 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire (8 SWG GI Wire) | Each | 19.0 | 19.0 | 1.0 | False | None | None | False | None | False | 19.0 | 0 |
4025170 | 156012 | None | PWD Ele-SR 2022-2023, Item code 69.1 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 | Each | 335.0 | 335.0 | 1.0 | False | None | None | False | None | False | 335.0 | 0 |