1726322479000 | 0 | None | None | Buildings | Construction of Raita Bhavana Near Bakkeshwar Temple at Devangaon Village in Almel Taluka Vijayapur District Under B.L.I.S. Afzalpur | 8471823.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4009323 | 155191 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m SRP Vol-1 8/1.14.1 | Cum | 76.65 | 76.65 | 282.7 | False | None | None | False | None | False | 21668.955 | 0 | 4009324 | 155191 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.4) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6014.4 | 6014.4 | 83.9 | False | None | None | False | None | False | 504608.16 | 0 | 4009325 | 155191 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9) | Cum | 214.2 | 214.2 | 232.82 | False | None | None | False | None | False | 49870.044 | 0 | 4009326 | 155191 | None | code04 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6174.0 | 6174.0 | 3.41 | False | None | None | False | None | False | 21053.34 | 0 | 4009327 | 155191 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 6780.19 | 6780.19 | 35.87 | False | None | None | False | None | False | 243205.4153 | 0 | 4009328 | 155191 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 11042.01 | 11042.01 | 16.61 | False | None | None | False | None | False | 183407.7861 | 0 | 4009329 | 155191 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 10392.48 | 10392.48 | 24.83 | False | None | None | False | None | False | 258045.2784 | 0 | 4009330 | 155191 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 9418.19 | 9418.19 | 1.15 | False | None | None | False | None | False | 10830.9185 | 0 | 4009331 | 155191 | None | code09 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). SRP- Vol-II (84/11.32) | Per Kg | 96.6 | 96.6 | 10710.8 | False | None | None | False | None | False | 1034663.28 | 0 | 4009332 | 155191 | None | code10 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.5) 35 mm thick one side teak and one side commercial | Sqm | 3617.25 | 3617.25 | 13.44 | False | None | None | False | None | False | 48615.84 | 0 | 4009333 | 155191 | None | code11 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12) | Cum | 79111.2 | 79111.2 | 0.2 | False | None | None | False | None | False | 15822.24 | 0 | 4009334 | 155191 | None | code12 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A) | Per Kg | 152.25 | 152.25 | 894.6 | False | None | None | False | None | False | 136202.85 | 0 | 4009335 | 155191 | None | code13 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) :SRP- Vol-II (9/5.1.1 | Cum | 5065.2 | 5065.2 | 25.91 | False | None | None | False | None | False | 131239.332 | 0 | 4009336 | 155191 | None | code14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8) | Cum | 7024.5 | 7024.5 | 134.67 | False | None | None | False | None | False | 945989.415 | 0 | 4009337 | 155191 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2) | Sqm | 241.5 | 241.5 | 1331.73 | False | None | None | False | None | False | 321612.795 | 0 | 4009338 | 155191 | None | code16 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2) | Sqm | 207.9 | 207.9 | 15.36 | False | None | None | False | None | False | 3193.344 | 0 | 4009339 | 155191 | None | code17 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (91/11.44) | Sqm | 3655.05 | 3655.05 | 42.6 | False | None | None | False | None | False | 155705.13 | 0 | 4009340 | 155191 | None | code18 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2)Size of Tile 600x600 mm | Sqm | 1324.05 | 1324.05 | 855.2 | False | None | None | False | None | False | 1132327.56 | 0 | 4009341 | 155191 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25) | Sqm | 110.25 | 110.25 | 807.84 | False | None | None | False | None | False | 89064.36 | 0 | 4009342 | 155191 | None | code20 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Apex Paint) SRP- Vol-II (45/8.28) | Sqm | 69.3 | 69.3 | 655.97 | False | None | None | False | None | False | 45458.721 | 0 | 4009343 | 155191 | None | code21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.40) | Sqm | 94.5 | 94.5 | 807.84 | False | None | None | False | None | False | 76340.88 | 0 | 4009344 | 155191 | None | code22 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8) | Cum | 422.1 | 422.1 | 361.76 | False | None | None | False | None | False | 152698.896 | 0 | 4009345 | 155191 | None | code23 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 550x400 mm .SRP- Vol-II (128/14.25.2) | Each | 895.65 | 895.65 | 2.0 | False | None | None | False | None | False | 1791.3 | 0 | 4009346 | 155191 | None | code24 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mmSRP- Vol-II (178/20.44.2) | Each | 6440.7 | 6440.7 | 2.0 | False | None | None | False | None | False | 12881.4 | 0 | 4009347 | 155191 | None | code25 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(PWD CSR 2021-22 Vol-3 P.no.15, I.No.3.6) | Sqm | 864.15 | 864.15 | 132.46 | False | None | None | False | None | False | 114465.309 | 0 | 4009348 | 155191 | None | code26 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
(PWD CSR 2021-22 Vol-2 P.no. 83, I.No.11.28) | Kg | 525.0 | 525.0 | 76.0 | False | None | None | False | None | False | 39900.0 | 0 | 4009349 | 155191 | None | code27 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (81/11.16.2) | Kg | 142.8 | 142.8 | 12800.0 | False | None | None | False | None | False | 1827840.0 | 0 | 4009350 | 155191 | None | code28 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts an nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² SRP- Vol-II (21/7.1.1) | Sqm | 834.75 | 834.75 | 787.77 | False | None | None | False | None | False | 657591.0075 | 0 | 4009351 | 155191 | None | code29 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SRP- Vol-II (82/11.25.2) | Kg | 113.4 | 113.4 | 250.0 | False | None | None | False | None | False | 28350.0 | 0 | 4009352 | 155191 | None | code30 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (Elec SR -2022-23)P.No.2, I.No.1.2 (1.2.2) (25mm dia 2mm thick) | Mtr | 70.0 | 70.0 | 60.0 | False | None | None | False | None | False | 4200.0 | 0 | 4009353 | 155191 | None | code31 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Elec SR -2022-23)P.No.2, I.No.1.3 (1.3.2) (25mm dia 2mm thick)(Groove) | Mtr | 80.0 | 80.0 | 60.0 | False | None | None | False | None | False | 4800.0 | 0 | 4009354 | 155191 | None | code32 | Supplying and fixing PVC/metal conduit Deep junction box (Elec SR -2022-23)P.No.2 & 3, I.No.1.5(1.5.2) (25mm dia 2mm thick) | Mtr | 51.0 | 51.0 | 8.0 | False | None | None | False | None | False | 408.0 | 0 | 4009355 | 155191 | None | code33 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6 (1,6.3) (10"x7"x3") | Each | 101.0 | 101.0 | 6.0 | False | None | None | False | None | False | 606.0 | 0 | 4009356 | 155191 | None | code34 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6 (1,6.4) (8"x6"x3") | Each | 75.0 | 75.0 | 3.0 | False | None | None | False | None | False | 225.0 | 0 | 4009357 | 155191 | None | code35 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6.2 (Fan Box) | No | 105.0 | 105.0 | 4.0 | False | None | None | False | None | False | 420.0 | 0 | 4009358 | 155191 | None | code36 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A (Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.1) (Point Wiring) | Point | 276.0 | 276.0 | 8.0 | False | None | None | False | None | False | 2208.0 | 0 | 4009359 | 155191 | None | code37 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.2) (Point Wiring) | Point | 386.0 | 386.0 | 4.0 | False | None | None | False | None | False | 1544.0 | 0 | 4009360 | 155191 | None | code38 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch(Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.3) (Point Wiring) | Point | 567.0 | 567.0 | 5.0 | False | None | None | False | None | False | 2835.0 | 0 | 4009361 | 155191 | None | code39 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010(Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.2) (3C X 1.5 mm2) | Mtr | 69.0 | 69.0 | 350.0 | False | None | None | False | None | False | 24150.0 | 0 | 4009362 | 155191 | None | code40 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010.(Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.3) (2.5 Sq.mm) | Mtr | 88.0 | 88.0 | 350.0 | False | None | None | False | None | False | 30800.0 | 0 | 4009363 | 155191 | None | code41 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010. (Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.4) (4 Sq.mm) | Mtr | 112.0 | 112.0 | 350.0 | False | None | None | False | None | False | 39200.0 | 0 | 4009364 | 155191 | None | code42 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 (Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.5) (6 Sq.mm) | Mtr | 158.0 | 158.0 | 100.0 | False | None | None | False | None | False | 15800.0 | 0 | 4009365 | 155191 | None | code43 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 ((Elec SR -2022-23)P.No.15, I.No.3.1 (3.1.2) (6A 'U' Socket) | Each | 143.0 | 143.0 | 10.0 | False | None | None | False | None | False | 1430.0 | 0 | 4009366 | 155191 | None | code44 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A (Elec SR -2022-23)P.No.18, I.No.3.15 (3.1.1) (6A Switches) | Each | 121.0 | 121.0 | 4.0 | False | None | None | False | None | False | 484.0 | 0 | 4009367 | 155191 | None | code45 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (Elec SR -2022-23)P.No.15, I.No.3.2 (2Way Switches) | Each | 162.0 | 162.0 | 5.0 | False | None | None | False | None | False | 810.0 | 0 | 4009368 | 155191 | None | code46 | Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A(Elec SR -2022-23)P.No.15, I.No.3.3 (3.3.1) (32 A Flush type DP's) | Each | 91.0 | 91.0 | 3.0 | False | None | None | False | None | False | 273.0 | 0 | 4009369 | 155191 | None | code47 | Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (Elec SR -2022-23)P.No.15, I.No.3.3 (3.3.3) (16A 'U' Socket) | Each | 149.0 | 149.0 | 3.0 | False | None | None | False | None | False | 447.0 | 0 | 4009370 | 155191 | None | code48 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) (Elec SR -2022-23)P.No.78, I.No.6.3 (6.3.1) (Ceiling Fan) | Each | 2085.0 | 2085.0 | 15.0 | False | None | None | False | None | False | 31275.0 | 0 | 4009371 | 155191 | None | code49 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (Elec SR -2022-23)P.No.47, I.No.5.18.12 6 Way TP & N | Each | 3735.0 | 3735.0 | 3.0 | False | None | None | False | None | False | 11205.0 | 0 | 4009372 | 155191 | None | code50 | Supplying & fixing of retrofit type - LED bulb (Elec SR -2022-23)P.No.38 ITEM NO. 11.11.7( 18W Bulb)
| No | 436.0 | 436.0 | 60.0 | False | None | None | False | None | False | 26160.0 | 0 | 4009373 | 155191 | None | code51 | Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.(Elec SR -2022-23)P.No.38 ITEM NO11.14.21 x 4' Tube light fitting. | Each | 324.0 | 324.0 | 25.0 | False | None | None | False | None | False | 8100.0 | 0 |
|