4008345 | 155138 | None | code01 | JOGUR: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 285.6 | 285.6 | 87.57 | False | None | None | False | None | False | 25009.992 | 0 |
4008346 | 155138 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse
aggregates | Cum | 5831.7 | 5831.7 | 26.34 | False | None | None | False | None | False | 153606.978 | 0 |
4008347 | 155138 | None | code03 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6564.8 | 6564.8 | 12.96 | False | None | None | False | None | False | 85079.808 | 0 |
4008348 | 155138 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5065.2 | 5065.2 | 18.88 | False | None | None | False | None | False | 95630.976 | 0 |
4008349 | 155138 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5693.1 | 5693.1 | 12.73 | False | None | None | False | None | False | 72473.163 | 0 |
4008350 | 155138 | None | code06 | Providing Raised and cut pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Cum | 381.15 | 381.15 | 36.67 | False | None | None | False | None | False | 13976.7705 | 0 |
4008351 | 155138 | None | code07 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 100.37 | 100.37 | 3860.06 | False | None | None | False | None | False | 387434.2222 | 0 |
4008352 | 155138 | None | code08 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 422.1 | 422.1 | 113.95 | False | None | None | False | None | False | 48098.295 | 0 |
4008353 | 155138 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Foundation, coloumn and piers | Cum | 7109.3 | 7109.3 | 8.92 | False | None | None | False | None | False | 63414.956 | 0 |
4008354 | 155138 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beams & Lintels of Building,Roof | Cum | 7727.5 | 7727.5 | 41.24 | False | None | None | False | None | False | 318682.1 | 0 |
4008355 | 155138 | None | code11 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidentalcharges complete as per the direction of engineer incharge of work | Cum | 9363.9 | 9363.9 | 45.59 | False | None | None | False | None | False | 426900.201 | 0 |
4008356 | 155138 | None | code12 | Providing Mathi / Nandi wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications | Cum | 77658.0 | 77658.0 | 1.41 | False | None | None | False | None | False | 109497.78 | 0 |
4008357 | 155138 | None | code13 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 4227.3 | 4227.3 | 8.31 | False | None | None | False | None | False | 35128.863 | 0 |
4008358 | 155138 | None | code14 | Providing and fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. Wall thickness of frame and sash shall be of 2 mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T and P s shall not be made) | Sqm | 4319.7 | 4319.7 | 14.4 | False | None | None | False | None | False | 62203.68 | 0 |
4008359 | 155138 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 304.2 | 304.2 | 633.2 | False | None | None | False | None | False | 192619.44 | 0 |
4008360 | 155138 | None | code16 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer in-charge. | Sqm | 19.95 | 19.95 | 633.2 | False | None | None | False | None | False | 12632.34 | 0 |
4008361 | 155138 | None | code17 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 114.45 | 114.45 | 415.8 | False | None | None | False | None | False | 47588.31 | 0 |
4008362 | 155138 | None | code18 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 59.85 | 59.85 | 312.22 | False | None | None | False | None | False | 18686.367 | 0 |
4008363 | 155138 | None | code19 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge | Sqm | 43.05 | 43.05 | 15.82 | False | None | None | False | None | False | 681.051 | 0 |
4008364 | 155138 | None | code20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 136.5 | 136.5 | 38.49 | False | None | None | False | None | False | 5253.885 | 0 |
4008365 | 155138 | None | code21 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at 1.43 ltr/10 m over and including priming coat of exterior primer applied at 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Cum | 138.6 | 138.6 | 300.61 | False | None | None | False | None | False | 41664.546 | 0 |
4008366 | 155138 | None | code22 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications | Sqm | 1390.2 | 1390.2 | 166.65 | False | None | None | False | None | False | 231676.83 | 0 |
4008367 | 155138 | None | code23 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 2061.15 | 2061.15 | 7.96 | False | None | None | False | None | False | 16406.754 | 0 |
4008368 | 155138 | None | code24 | HERUR: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m SRP Vol-1 8/1.14.1 | Cum | 76.65 | 76.65 | 176.49 | False | None | None | False | None | False | 13527.9585 | 0 |
4008369 | 155138 | None | code25 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.4) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6014.4 | 6014.4 | 36.29 | False | None | None | False | None | False | 218262.576 | 0 |
4008370 | 155138 | None | code26 | Providing Random rubble masonry with hard stone in foundation nd plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) :). | Cum | 4987.5 | 4987.5 | 19.91 | False | None | None | False | None | False | 99301.125 | 0 |
4008371 | 155138 | None | code27 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.2.1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6794.93 | 6794.93 | 62.0 | False | None | None | False | None | False | 421285.66 | 0 |
4008372 | 155138 | None | code28 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 7144.83 | 7144.83 | 8.0 | False | None | None | False | None | False | 57158.64 | 0 |
4008373 | 155138 | None | code29 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9) | Cum | 214.2 | 214.2 | 110.42 | False | None | None | False | None | False | 23651.964 | 0 |
4008374 | 155138 | None | code30 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8) | Cum | 422.1 | 422.1 | 240.8 | False | None | None | False | None | False | 101641.68 | 0 |
4008375 | 155138 | None | code31 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7794.36 | 7794.36 | 62.36 | False | None | None | False | None | False | 486056.2896 | 0 |
4008376 | 155138 | None | code32 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8) | Cum | 7295.4 | 7295.4 | 47.12 | False | None | None | False | None | False | 343759.248 | 0 |
4008377 | 155138 | None | code33 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12) | Cum | 79111.2 | 79111.2 | 1.213 | False | None | None | False | None | False | 95961.8856 | 0 |
4008378 | 155138 | None | code34 | Providing and fixing in position fully panalled shutters of Mathi/Nandi wood for doors with stiles and rails of 40mm thick, wih bottom and lock rails 180 mm wide top and stiles 100 mm wide as per drawing and panels of 25 mm thick including cost of materials labour usage charges complete as per specifications, (excluding cost of fixtures) | Sqm | 4783.0 | 4783.0 | 11.34 | False | None | None | False | None | False | 54239.22 | 0 |
4008379 | 155138 | None | code35 | Providing and fixing in position fully panalled shutters of Mathi/Nandi wood for windows with stiles and rails of 30mm thick, 75nn wide in two halves with panels of 20 mm thick including cost of materials labour usage charges complete as per specifications, (excluding cost of fixtures) | Sqm | 4302.9 | 4302.9 | 34.524 | False | None | None | False | None | False | 148553.3196 | 0 |
4008380 | 155138 | None | code36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A) | Sqm | 150.15 | 150.15 | 687.96 | False | None | None | False | None | False | 103297.194 | 0 |
4008381 | 155138 | None | code37 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9418.18 | 9418.18 | 1.32 | False | None | None | False | None | False | 12431.9976 | 0 |
4008382 | 155138 | None | code38 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). SRP- Vol-II (84/11.32) | Kg | 87.15 | 87.15 | 12115.41 | False | None | None | False | None | False | 1055857.9815 | 0 |
4008383 | 155138 | None | code39 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2) | Sqm | 207.9 | 207.9 | 279.22 | False | None | None | False | None | False | 58049.838 | 0 |
4008384 | 155138 | None | code40 | Providing 18 mm cement plaster on the rough side of single or half brick wall of mix :1:5 (1 cement: 5 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2) | Sqm | 322.35 | 322.35 | 521.98 | False | None | None | False | None | False | 168260.253 | 0 |
4008385 | 155138 | None | code41 | Providing white washing with lime to give an even shade New work (three coats) with lime of approved qualityy including cost of materials, labour complete as per specifications and as per directions of Engineer in Charge. | Sqm | 19.95 | 19.95 | 683.43 | False | None | None | False | None | False | 13634.4285 | 0 |
4008386 | 155138 | None | code42 | Wall painting with premium acrylic emulsion paint of inteior grade having VOC (Volatiele Organic Compound) content less than 50 grams / litre of approved brand and manufacture, including applying additional coats wherever required to achieve eve shade and colour. Two coats as per specifications and as per directions of Engineer in Charge. | Sqm | 82.95 | 82.95 | 396.46 | False | None | None | False | None | False | 32886.357 | 0 |
4008387 | 155138 | None | code43 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28) | Sqm | 69.3 | 69.3 | 305.29 | False | None | None | False | None | False | 21156.597 | 0 |
4008388 | 155138 | None | code44 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications. | Sqm | 1251.6 | 1251.6 | 288.87 | False | None | None | False | None | False | 361549.692 | 0 |
4008389 | 155138 | None | code45 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 111.3 | 111.3 | 34.52 | False | None | None | False | None | False | 3842.076 | 0 |
4008390 | 155138 | None | code46 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 43.05 | 43.05 | 60.33 | False | None | None | False | None | False | 2597.2065 | 0 |
4008391 | 155138 | None | code47 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 60.33 | False | None | None | False | None | False | 6651.3825 | 0 |
4008392 | 155138 | None | code48 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 g per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. | Sqm | 605.85 | 605.85 | 156.66 | False | None | None | False | None | False | 94912.461 | 0 |
4008393 | 155138 | None | code49 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Mtr | 61.0 | 61.0 | 75.0 | False | None | None | False | None | False | 4575.0 | 0 |
4008394 | 155138 | None | code50 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick | Mtr | 75.0 | 75.0 | 25.0 | False | None | None | False | None | False | 1875.0 | 0 |
4008395 | 155138 | None | code51 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Group-A Short point up to 3-m from tapping point to outlet via switch (PWD Elect. DSR 2021-22 I.No. 2.1.1) | Point | 276.0 | 276.0 | 10.0 | False | None | None | False | None | False | 2760.0 | 0 |
4008396 | 155138 | None | code52 | Point wiring using Copper wire without switch: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated, 2X1.5 Sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet Group-A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (PWD Elect. DSR 2021-22I.No. 2.1.2) | Point | 386.0 | 386.0 | 10.0 | False | None | None | False | None | False | 3860.0 | 0 |
4008397 | 155138 | None | code53 | Point wiring using Copper wire without switch: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated, 2X1.5 Sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet Group-A Long point above 6-meter upto 10-meter from tapping point to out let via switch box (PWD Elect. DSR 2021-22 I.No. 2.1.3) | Point | 567.0 | 567.0 | 8.0 | False | None | None | False | None | False | 4536.0 | 0 |
4008398 | 155138 | None | code54 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box (PWD Elect. DSR 2021-22 I.No. 3.7) | Each | 747.0 | 747.0 | 2.0 | False | None | None | False | None | False | 1494.0 | 0 |
4008399 | 155138 | None | code55 | Supplying and fixing 1-3 module superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.5.1). | Each | 152.0 | 152.0 | 5.0 | False | None | None | False | None | False | 760.0 | 0 |
4008400 | 155138 | None | code56 | Supplying and fixing 4-module superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.5.2). | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
4008401 | 155138 | None | code57 | Supplying and fixing 6-module superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.5.3). | Each | 244.0 | 244.0 | 5.0 | False | None | None | False | None | False | 1220.0 | 0 |
4008402 | 155138 | None | code58 | Supplying and fixing 8-module superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.5.4). | Each | 302.0 | 302.0 | 5.0 | False | None | None | False | None | False | 1510.0 | 0 |
4008403 | 155138 | None | code59 | Supplying and fixing of 6 amps one-way modular switch and connected accessories on existing modular switc plate as per IS 3854 and IS 1293 (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.6.1) | Each | 88.0 | 88.0 | 5.0 | False | None | None | False | None | False | 440.0 | 0 |
4008404 | 155138 | None | code60 | Supplying and fixing of 6 amps 2-way modular switch and connected accessories on existing modular switc plate as per IS 3854 and IS 1293 (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.6.2) | Each | 152.0 | 152.0 | 5.0 | False | None | None | False | None | False | 760.0 | 0 |
4008405 | 155138 | None | code61 | Supplying and fixing of stepped fan regulator and connected accessories on existing modular switc plate as per IS 3854 and IS 1293 (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.6.4) | Each | 313.0 | 313.0 | 5.0 | False | None | None | False | None | False | 1565.0 | 0 |
4008406 | 155138 | None | code62 | Supplying and fixing of 6 amps bell push and connected accessories on existing modular switc plate as per IS 3854 and IS 1293 (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.6.9) | Each | 159.0 | 159.0 | 5.0 | False | None | None | False | None | False | 795.0 | 0 |
4008407 | 155138 | None | code63 | Supplying and fixing of TV/ Telephone Socket and connected accessories on existing modular switc plate as per IS 3854 and IS 1293 (PWD Elect. DSR 2021-22 P.No. 5 I.No. 3.6.12) | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 |
4008408 | 155138 | None | code64 | Wiring for lighting/ power circuit with 1.5 Sqmm using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694: confirming to latest amendment (PWD Elect. DSR 2021-22 P.No. 6 I.No. 2.3.2) | Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
4008409 | 155138 | None | code65 | Wiring for lighting/ power circuit with 2.5 Sqmm using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694: confirming to latest amendment (PWD Elect. DSR 2021-22 P.No. 6 I.No. 2.3.3) | Mtr | 40.0 | 40.0 | 50.0 | False | None | None | False | None | False | 2000.0 | 0 |
4008410 | 155138 | None | code66 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | No | 118.0 | 118.0 | 5.0 | False | None | None | False | None | False | 590.0 | 0 |
4008411 | 155138 | None | code67 | Supplying of 2x4 feet PVC batten with integrated LED tube 20/22W with high quality diffuser with life of 25000 burning hours and 70 percent lumen maintenance with CRI is more than 80. Power input: 220-240V at 50/60 Hz and power factor is more than 0.90 along with CE approved 2 years warranty against any manufacturing defect working under standard electrical condition (PWD Elect. DSR 2021-22 I.No. 11.3.3) | Each | 1197.0 | 1197.0 | 15.0 | False | None | None | False | None | False | 17955.0 | 0 |
4008412 | 155138 | None | code68 | Supply of LED street light luminaire with pressure die cast aluminium housing body for optimal thermal dissiption lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen maintenance of 70percent, maximum light intensity should be betwwen 60 degrees to 70 degrees. CCT is more than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire more than IK08. power factor more than 0.9 with mains , Surge protection-Min 5KV along with over voltage/ Overload, shortcircuit/ miss wiring protection. Compatible for pole mounting with outer dia of 40mm to 50 mm. Universal Voltage driver to operate wide range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598. LM 79 and LM80 Adherence with ROHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintainance at the sight site location with minimized minimal tools. LED light fixture with 25 Watts system power consuption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any goverment certified agency & design & development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing/ Body part. Warrenty of two years against any manufcaturing defect working under standrad electrical conditions as mentioned below should be given by LED manufacturer & cree/ Nichia/ Lumileds/ Osram make LED source (PWD Elect. DSR 2021-22 P.No. 67 I.No. 12.8.2) | No | 2000.0 | 2000.0 | 1.0 | False | None | None | False | None | False | 2000.0 | 0 |
4008413 | 155138 | None | code69 | Supplying capacitor type 48” sweep (1200 mm) regular model ceiling fan with down rod, blades, shackle, canopies, etc. for operation on 230 volts, 50 cycles, single phase AC supply confirming to IS-374-1979 and with double ball bearing system (PWD Elect. DSR 2021-22 I.No. 7.3.1) | Each | 2085.0 | 2085.0 | 15.0 | False | None | None | False | None | False | 31275.0 | 0 |
4008414 | 155138 | None | code70 | Fixing all types and all capacities of fluorescent/ false ceiling/ spot light/ CFL/ LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/0.0076” twin twisted PVC insulated wires, required number of round blocks and clamps. (PWD Elect. DSR 2021-22 P.No. 45 I.No. 13.7.1) | Each | 119.0 | 119.0 | 15.0 | False | None | None | False | None | False | 1785.0 | 0 |
4008415 | 155138 | None | code71 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 162.0 | 162.0 | 15.0 | False | None | None | False | None | False | 2430.0 | 0 |
4008416 | 155138 | None | code72 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.16 A | Each | 200.0 | 200.0 | 5.0 | False | None | None | False | None | False | 1000.0 | 0 |
4008417 | 155138 | None | code73 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (PWD Elect. DSR 2021-22 P.No. 24 I.No. 5.17.1) | Each | 523.0 | 523.0 | 3.0 | False | None | None | False | None | False | 1569.0 | 0 |
4008418 | 155138 | None | code74 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 1591.0 | 1591.0 | 3.0 | False | None | None | False | None | False | 4773.0 | 0 |
4008419 | 155138 | None | code75 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole | Each | 4548.0 | 4548.0 | 1.0 | False | None | None | False | None | False | 4548.0 | 0 |
4008420 | 155138 | None | code76 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. | Each | 1242.0 | 1242.0 | 1.0 | False | None | None | False | None | False | 1242.0 | 0 |
4008421 | 155138 | None | code77 | Fabricating supplying and mounting MS box made out 14 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat disspation, provided with hinged front cover, equipped with tamper proof locking arrangements. With suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7-tanks treatment with powder coated paint coated paint and finally finished with approved colour etc., complete a) MS Box of 14 SWG guage for panel =8100 sqcm at Rs. 0.40/ sqcm (PWD Elect. DSR 2019-20 P.No. 30 I.No. 5.42.1). | Sq CM | 0.43 | 0.43 | 2000.0 | False | None | None | False | None | False | 860.0 | 0 |