3913388 | 150931 | None | APT1 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer | Cum | 494.8 | 494.8 | 16.61 | False | None | None | False | None | False | 8218.628 | 0 |
3913389 | 150931 | None | APT2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) for staircase M25. Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per the directions and instructions of engineer in charge-(Second Floor) | Cum | 6940.69 | 6940.69 | 43.64 | False | None | None | False | None | False | 302891.7116 | 0 |
3913390 | 150931 | None | APT3 | Providing and removing centering, shuttering, strutting, propping etc., for Columns-(Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Cum | 4858.48 | 4858.48 | 4.158 | False | None | None | False | None | False | 20201.55984 | 0 |
3913391 | 150931 | None | APT4 | Providing and removing centering, shuttering, strutting, propping etc.,For Beams and Lintels (Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Cum | 4164.42 | 4164.42 | 8.25 | False | None | None | False | None | False | 34356.465 | 0 |
3913392 | 150931 | None | APT5 | Providing and removing centering, shuttering, strutting, propping etc., for slabs (Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Cum | 3470.35 | 3470.35 | 33.146 | False | None | None | False | None | False | 115028.2211 | 0 |
3913393 | 150931 | None | APT6 | Providing and removing centering, shuttering, strutting, propping etc., for Portico (Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer | Cum | 3123.31 | 3123.31 | 6.13 | False | None | None | False | None | False | 19145.8903 | 0 |
3913394 | 150931 | None | APT7 | Providing Thermo - Mechanically Treated bars of grade Fe-500 D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge . (The laps and wastages shall not be measured separately) (Second Floor) | Kg | 103.22 | 103.22 | 2590.95 | False | None | None | False | None | False | 267437.859 | 0 |
3913395 | 150931 | None | APT8 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Second Floor) | Sqm | 93.13 | 93.13 | 398.7 | False | None | None | False | None | False | 37130.931 | 0 |
3913396 | 150931 | None | APT9 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge-(Second Floor) | Sqm | 44.88 | 44.88 | 641.581 | False | None | None | False | None | False | 28794.15528 | 0 |
3913397 | 150931 | None | APT10 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge -(Second Floor) | Sqm | 88.64 | 88.64 | 585.0 | False | None | None | False | None | False | 51854.4 | 0 |
3913398 | 150931 | None | APT11 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge-(Second Floor ) | Sqm | 106.59 | 106.59 | 209.0 | False | None | None | False | None | False | 22277.31 | 0 |
3913399 | 150931 | None | APT12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaSFolding and curing, usage charges of machinery etc complete as per specifications, as per the directions and instructions of engineer in charge-(Second Floor) | Sqm | 1341.91 | 1341.91 | 270.8485 | False | None | None | False | None | False | 363454.310635 | 0 |
3913400 | 150931 | None | APT13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scafolding and curing, usage charges of machinery etc complete as per specifications, as per the directions and instructions of engineer in charge-(Second Floor) | Sqm | 1054.68 | 1054.68 | 50.466 | False | None | None | False | None | False | 53225.48088 | 0 |
3913401 | 150931 | None | APT14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Second Floor) | Kg | 162.69 | 162.69 | 106.3125 | False | None | None | False | None | False | 17295.980625 | 0 |
3913402 | 150931 | None | APT15 | Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made)including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge .(Second Floor) | Sqm | 8123.28 | 8123.28 | 15.86 | False | None | None | False | None | False | 128835.2208 | 0 |
3913403 | 150931 | None | APT16 | Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Second Floor) | Sqm | 532.95 | 532.95 | 57.3 | False | None | None | False | None | False | 30538.035 | 0 |
3913404 | 150931 | None | APT17 | Providing and fixing factory made 100PERCENT carpentery friendly ready to use Single Solid Plain wood Polymer composite (WPC) flush shutter of 30mm thickness which is anti termite and having high water absorption property. The door includes the cost of materials, transportation, labour and fixing charges. including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Second Floor) | Sqm | 3902.32 | 3902.32 | 16.065 | False | None | None | False | None | False | 62690.7708 | 0 |
3913405 | 150931 | None | APT18 | Providing and fixing aluminium tubular handle bar 32 mm outer dia,3.0 mm thick and 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.: Anodized (AC 15 ) aluminium tubular handle bar including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge (Second Floor) | Each | 523.97 | 523.97 | 12.0 | False | None | None | False | None | False | 6287.64 | 0 |
3913406 | 150931 | None | APT19 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc.including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 122.3 | 122.3 | 12.0 | False | None | None | False | None | False | 1467.6 | 0 |
3913407 | 150931 | None | APT20 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (SECOND Floor) | Each | 92.0 | 92.0 | 36.0 | False | None | None | False | None | False | 3312.0 | 0 |
3913408 | 150931 | None | APT21 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm-(Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge . | Each | 378.11 | 378.11 | 12.0 | False | None | None | False | None | False | 4537.32 | 0 |
3913409 | 150931 | None | APT22 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge -(Second Floor) . | Each | 387.09 | 387.09 | 8.0 | False | None | None | False | None | False | 3096.72 | 0 |
3913410 | 150931 | None | APT23 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding oSF corners wherever required smooth rendering, providing and removing scaSFolding, including cost of materials, labour, curing complete as per specifications and as per directions | Sqm | 238.99 | 238.99 | 187.7443 | False | None | None | False | None | False | 44869.010257 | 0 |
3913411 | 150931 | None | APT24 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding oSF corners wherever required smooth rendering, providing and removing scaSFolding, including cost of materials, labour, curing complete as per specifications and as per directions | Sqm | 278.26 | 278.26 | 639.5628 | False | None | None | False | None | False | 177964.744728 | 0 |
3913412 | 150931 | None | APT25 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand)\ finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding oSF corners wherever required smooth rendering, providing and removing scaSFolding, including cost of materials, labour, curing complete as per specifications and as per directions | Sqm | 344.45 | 344.45 | 110.1515 | False | None | None | False | None | False | 37941.684175 | 0 |
3913413 | 150931 | None | APT26 | Providing and laying Vitrified tiles in diSFerent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08PERCENT and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions | Sqm | 1288.06 | 1288.06 | 164.4977 | False | None | None | False | None | False | 211882.907462 | 0 |
3913414 | 150931 | None | APT27 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry AT 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete as per the directions and instructions of engineer | Sqm | 1081.61 | 1081.61 | 39.501 | False | None | None | False | None | False | 42724.67661 | 0 |
3913415 | 150931 | None | APT28 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer | Sqm | 2118.34 | 2118.34 | 19.057 | False | None | None | False | None | False | 40369.20538 | 0 |
3913416 | 150931 | None | APT29 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge-(Second Floor) . | Kg | 134.64 | 134.64 | 800.0 | False | None | None | False | None | False | 107712.0 | 0 |
3913417 | 150931 | None | APT30 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Kg | 561.0 | 561.0 | 524.0 | False | None | None | False | None | False | 293964.0 | 0 |
3913418 | 150931 | None | APT31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 550.0 | 550.0 | 100.0 | False | None | None | False | None | False | 55000.0 | 0 |
3913419 | 150931 | None | APT32 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry AT 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge -(Ground Floor) | Sqm | 1060.4 | 1060.4 | 43.75 | False | None | None | False | None | False | 46392.5 | 0 |
3913420 | 150931 | None | APT33 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400PERCENT and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats AT 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer AT150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certifiedmanufacturers including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Terrace -Third Floor) | Sqm | 844.09 | 844.09 | 203.4 | False | None | None | False | None | False | 171687.906 | 0 |
3913421 | 150931 | None | APT34 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) GREATER 78, solar reflection GREATER 0.70 and initial emittance GREATER 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner including cost of materials, labour, usage charges of machinery complete as per specifications and including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge (Terrace ) | Sqm | 1231.57 | 1231.57 | 203.4 | False | None | None | False | None | False | 250501.338 | 0 |
3913422 | 150931 | None | APT35 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Short point up to 3Mtr from tapping point to out let via switch including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Point | 276.0 | 276.0 | 30.0 | False | None | None | False | None | False | 8280.0 | 0 |
3913423 | 150931 | None | APT36 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Medium point above 3mtr up to 6Mtr from tapping point to out let via switch including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Point | 386.0 | 386.0 | 40.0 | False | None | None | False | None | False | 15440.0 | 0 |
3913424 | 150931 | None | APT37 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet--Above 6Mtr up to 10Mtr from tapping Point to out let via switch including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Point | 567.0 | 567.0 | 20.0 | False | None | None | False | None | False | 11340.0 | 0 |
3913425 | 150931 | None | APT38 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Point | 721.0 | 721.0 | 15.0 | False | None | None | False | None | False | 10815.0 | 0 |
3913426 | 150931 | None | APT39 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge- 1-3Way | Each | 123.0 | 123.0 | 10.0 | False | None | None | False | None | False | 1230.0 | 0 |
3913427 | 150931 | None | APT40 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge- 4-5Way | Each | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
3913428 | 150931 | None | APT41 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6Way | Each | 212.0 | 212.0 | 4.0 | False | None | None | False | None | False | 848.0 | 0 |
3913429 | 150931 | None | APT42 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 8Way | Each | 250.0 | 250.0 | 2.0 | False | None | None | False | None | False | 500.0 | 0 |
3913430 | 150931 | None | APT43 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 10-12Way | Each | 325.0 | 325.0 | 10.0 | False | None | None | False | None | False | 3250.0 | 0 |
3913431 | 150931 | None | APT44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 1 to 3 Module | Each | 152.0 | 152.0 | 10.0 | False | None | None | False | None | False | 1520.0 | 0 |
3913432 | 150931 | None | APT45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge- 4Moudule | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
3913433 | 150931 | None | APT46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6Moudule | Each | 244.0 | 244.0 | 4.0 | False | None | None | False | None | False | 976.0 | 0 |
3913434 | 150931 | None | APT47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge- 8Moudule | Each | 302.0 | 302.0 | 2.0 | False | None | None | False | None | False | 604.0 | 0 |
3913435 | 150931 | None | APT48 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 10-12Moudule | Each | 363.0 | 363.0 | 10.0 | False | None | None | False | None | False | 3630.0 | 0 |
3913436 | 150931 | None | APT49 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6Amps one way. | Each | 88.0 | 88.0 | 150.0 | False | None | None | False | None | False | 13200.0 | 0 |
3913437 | 150931 | None | APT50 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6Amps Two way | Each | 152.0 | 152.0 | 10.0 | False | None | None | False | None | False | 1520.0 | 0 |
3913438 | 150931 | None | APT51 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6Amps 3way socket. | Each | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 |
3913439 | 150931 | None | APT52 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge Stepped Fan Regulator. | Each | 313.0 | 313.0 | 4.0 | False | None | None | False | None | False | 1252.0 | 0 |
3913440 | 150931 | None | APT53 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge16Amps one way switch | Each | 249.0 | 249.0 | 2.0 | False | None | None | False | None | False | 498.0 | 0 |
3913441 | 150931 | None | APT54 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge32Amps DP switch | Each | 375.0 | 375.0 | 2.0 | False | None | None | False | None | False | 750.0 | 0 |
3913442 | 150931 | None | APT55 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge6/16Amps universal socket | Each | 249.0 | 249.0 | 3.0 | False | None | None | False | None | False | 747.0 | 0 |
3913443 | 150931 | None | APT56 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 6/16Amps universal socket-TV/Telephone socket | Each | 147.0 | 147.0 | 2.0 | False | None | None | False | None | False | 294.0 | 0 |
3913444 | 150931 | None | APT57 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box and wired Completely. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge -20Amps | Each | 873.0 | 873.0 | 2.0 | False | None | None | False | None | False | 1746.0 | 0 |
3913445 | 150931 | None | APT58 | Supplying and fixing of MODULAR MCB Devices(Tripper) With Breaking capacity of 6KA - including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge16-32Amps | Each | 190.0 | 190.0 | 2.0 | False | None | None | False | None | False | 380.0 | 0 |
3913446 | 150931 | None | APT59 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-19/20mm dia 2mm thick including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 61.0 | 61.0 | 150.0 | False | None | None | False | None | False | 9150.0 | 0 |
3913447 | 150931 | None | APT60 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-19/20mm dia 2mm thick- including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 150.0 | False | None | None | False | None | False | 10500.0 | 0 |
3913448 | 150931 | None | APT61 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-19/20mm dia 2mm thick-32mm dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 2.5mm thick | Mtr | 93.0 | 93.0 | 20.0 | False | None | None | False | None | False | 1860.0 | 0 |
3913449 | 150931 | None | APT62 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)-19/20mm dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 2mm thick | Mtr | 75.0 | 75.0 | 150.0 | False | None | None | False | None | False | 11250.0 | 0 |
3913450 | 150931 | None | APT63 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)-19/20mm dia 2mm thick-25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 2mm thick | Mtr | 80.0 | 80.0 | 150.0 | False | None | None | False | None | False | 12000.0 | 0 |
3913451 | 150931 | None | APT64 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)-19/20mm dia 2mm thick-32mm dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge2.5mm thick | Mtr | 105.0 | 105.0 | 20.0 | False | None | None | False | None | False | 2100.0 | 0 |
3913452 | 150931 | None | APT65 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 and comfirming to GTP of Group-A .-1.5 sqmm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 26.0 | 26.0 | 500.0 | False | None | None | False | None | False | 13000.0 | 0 |
3913453 | 150931 | None | APT66 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 and comfirming to GTP of Group-A .-2.5 sqmm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 40.0 | 40.0 | 500.0 | False | None | None | False | None | False | 20000.0 | 0 |
3913454 | 150931 | None | APT67 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 and comfirming to GTP of Group-A .-4 sqmm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 59.0 | 59.0 | 60.0 | False | None | None | False | None | False | 3540.0 | 0 |
3913455 | 150931 | None | APT68 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 and comfirming to GTP of Group-A .-6 sqmm | Mtr | 87.0 | 87.0 | 20.0 | False | None | None | False | None | False | 1740.0 | 0 |
3913456 | 150931 | None | APT69 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 and comfirming to GTP of Group-A .-010 sqmm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 157.0 | 157.0 | 20.0 | False | None | None | False | None | False | 3140.0 | 0 |
3913457 | 150931 | None | APT70 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure -4 Way TP and N Snigle Door including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 3053.0 | 3053.0 | 1.0 | False | None | None | False | None | False | 3053.0 | 0 |
3913458 | 150931 | None | APT71 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure -4 Way TP and N Double Door 12 Way SP and N including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1591.0 | 1591.0 | 1.0 | False | None | None | False | None | False | 1591.0 | 0 |
3913459 | 150931 | None | APT72 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required -6-32Amps SP including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 523.0 | 523.0 | 5.0 | False | None | None | False | None | False | 2615.0 | 0 |
3913460 | 150931 | None | APT73 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required -50-63Amps TPN including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
3913461 | 150931 | None | APT74 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required -6-32Amps DP including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 |
3913462 | 150931 | None | APT75 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required 50-63Amps DP including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1376.0 | 1376.0 | 1.0 | False | None | None | False | None | False | 1376.0 | 0 |
3913463 | 150931 | None | APT76 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2536.0 | 2536.0 | 2.0 | False | None | None | False | None | False | 5072.0 | 0 |
3913464 | 150931 | None | APT77 | Supplying and fixing of 63Amps on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 5185.0 | 5185.0 | 1.0 | False | None | None | False | None | False | 5185.0 | 0 |
3913465 | 150931 | None | APT78 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70PERCENT lumen maintenance with CRI GREATER 80. Power Input: 220-240V AT50/60Hz and Power factor GREATER0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-LED square or round down light 15-18W including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1249.0 | 1249.0 | 8.0 | False | None | None | False | None | False | 9992.0 | 0 |
3913466 | 150931 | None | APT79 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIGREATER 70PERCENT. efficacy GREATER100 lumen per watt, 120degree beam spread, lifeGREATER 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF GREATER 0.95, power loss should LESSER 5PERCENT of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20PERCENT, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED modular down light 1x1 34 -22watts including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2869.0 | 2869.0 | 12.0 | False | None | None | False | None | False | 34428.0 | 0 |
3913467 | 150931 | None | APT80 | Supplying exhaust fan of 1440 RPM of 300mm (12) sizewith bracket blades complete for light duty suitable to operate on 230V 50Hz. AC Supply including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1542.0 | 1542.0 | 2.0 | False | None | None | False | None | False | 3084.0 | 0 |
3913468 | 150931 | None | APT81 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. (78/9.3)-48 Sweep (1200mm) Regular model including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2085.0 | 2085.0 | 13.0 | False | None | None | False | None | False | 27105.0 | 0 |
3913469 | 150931 | None | APT82 | Supplying wall mounting fan suitable to operate at single- phase 230v A.C. supply (78/9.4) 300mm Sweep including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2648.0 | 2648.0 | 5.0 | False | None | None | False | None | False | 13240.0 | 0 |
3913470 | 150931 | None | APT83 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall / ceiling / Rafter / Girders including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Each | 119.0 | 119.0 | 2.0 | False | None | None | False | None | False | 238.0 | 0 |
3913471 | 150931 | None | APT84 | Fixing a ceiling /Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 amps.ceiling rose,necessary length of 2310.0076 inch PVC insulated twin twisted copper wire and wiring including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Each | 281.0 | 281.0 | 2.0 | False | None | None | False | None | False | 562.0 | 0 |
3913472 | 150931 | None | APT85 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 702.0 | 702.0 | 2.0 | False | None | None | False | None | False | 1404.0 | 0 |
3913473 | 150931 | None | APT86 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete -16SWG including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sq CM | 0.38 | 0.38 | 50000.0 | False | None | None | False | None | False | 19000.0 | 0 |
3913474 | 150931 | None | APT87 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specificati-100Amps 4x30x6mm Aluminum Strips including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 2214.0 | 2214.0 | 1.0 | False | None | None | False | None | False | 2214.0 | 0 |
3913475 | 150931 | None | APT88 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint -40x40x6mm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 275.0 | 275.0 | 2.0 | False | None | None | False | None | False | 550.0 | 0 |
3913476 | 150931 | None | APT89 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 680.0 | 680.0 | 2.0 | False | None | None | False | None | False | 1360.0 | 0 |
3913477 | 150931 | None | APT90 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100PERCENT lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (100Amps 25kA) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | Each | 8265.0 | 8265.0 | 1.0 | False | None | None | False | None | False | 8265.0 | 0 |
3913478 | 150931 | None | APT91 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required -50-63Amps TPN including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
3913479 | 150931 | None | APT92 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required -50-63Amps DP including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 1376.0 | 1376.0 | 1.0 | False | None | None | False | None | False | 1376.0 | 0 |
3913480 | 150931 | None | APT93 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. 100Amps including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 7200.0 | 7200.0 | 1.0 | False | None | None | False | None | False | 7200.0 | 0 |
3913481 | 150931 | None | APT94 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 8370.0 | 8370.0 | 1.0 | False | None | None | False | None | False | 8370.0 | 0 |
3913482 | 150931 | None | APT95 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 464.0 | 464.0 | 3.0 | False | None | None | False | None | False | 1392.0 | 0 |
3913483 | 150931 | None | APT96 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 505.0 | 505.0 | 2.0 | False | None | None | False | None | False | 1010.0 | 0 |
3913484 | 150931 | None | APT97 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kvar | 432.0 | 432.0 | 3.0 | False | None | None | False | None | False | 1296.0 | 0 |
3913485 | 150931 | None | APT98 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. -300mmx300mmx214mm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 4054.0 | 4054.0 | 2.0 | False | None | None | False | None | False | 8108.0 | 0 |
3913486 | 150931 | None | APT99 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
3913487 | 150931 | None | APT100 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge-20 mm Dia (Second Floor) | Mtr | 241.23 | 241.23 | 100.0 | False | None | None | False | None | False | 24123.0 | 0 |
3913488 | 150931 | None | APT101 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of jointsincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.-25 mm Dia (Second Floor) | Mtr | 335.48 | 335.48 | 60.0 | False | None | None | False | None | False | 20128.8 | 0 |
3913489 | 150931 | None | APT102 | Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. -including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge 20 mm dia (Second Floor) | Each | 387.09 | 387.09 | 25.0 | False | None | None | False | None | False | 9677.25 | 0 |
3913490 | 150931 | None | APT103 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete-20 mm Dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 367.77 | 367.77 | 2.0 | False | None | None | False | None | False | 735.54 | 0 |
3913491 | 150931 | None | APT104 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete-25 mm Dia including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 426.62 | 426.62 | 2.0 | False | None | None | False | None | False | 853.24 | 0 |
3913492 | 150931 | None | APT105 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 2837.54 | 2837.54 | 12.0 | False | None | None | False | None | False | 34050.48 | 0 |
3913493 | 150931 | None | APT106 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 426.36 | 426.36 | 9.0 | False | None | None | False | None | False | 3837.24 | 0 |
3913494 | 150931 | None | APT107 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 975.02 | 975.02 | 4.0 | False | None | None | False | None | False | 3900.08 | 0 |
3913495 | 150931 | None | APT108 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Second Floor) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 5615.61 | 5615.61 | 8.0 | False | None | None | False | None | False | 44924.88 | 0 |
3913496 | 150931 | None | APT109 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge W.C. pan with ISI marked white solid plastic seat and lid (First Floor) | Each | 5560.56 | 5560.56 | 2.0 | False | None | None | False | None | False | 11121.12 | 0 |
3913497 | 150931 | None | APT110 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cisternincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Second Floor) | Each | 3967.39 | 3967.39 | 2.0 | False | None | None | False | None | False | 7934.78 | 0 |
3913498 | 150931 | None | APT111 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge Sand Cast Iron SandS as per IS:1729-(Second Floor) | Each | 1082.73 | 1082.73 | 10.0 | False | None | None | False | None | False | 10827.3 | 0 |
3913499 | 150931 | None | APT112 | Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter-Second Floor including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 283.87 | 283.87 | 35.0 | False | None | None | False | None | False | 9935.45 | 0 |
3913500 | 150931 | None | APT113 | Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter-including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(first floor) | Mtr | 278.3 | 278.3 | 25.0 | False | None | None | False | None | False | 6957.5 | 0 |
3913501 | 150931 | None | APT114 | Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof-(Second Floor) including cost of materials, labour, usage charges of machinery complete as per secifications and as per directions of the Engineer-in-Charge | No | 272.65 | 272.65 | 2.0 | False | None | None | False | None | False | 545.3 | 0 |
3913502 | 150931 | None | APT115 | Providing and placing on terrace (at all floor levels), polyethylene water storage tanks, IS:127001 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Terrace) | Ltr | 9.63 | 9.63 | 2000.0 | False | None | None | False | None | False | 19260.0 | 0 |
3913503 | 150931 | None | APT116 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(Second Floor) 15 mm nominal bore | Each | 369.14 | 369.14 | 5.0 | False | None | None | False | None | False | 1845.7 | 0 |
3913504 | 150931 | None | APT117 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 4811.4 | 4811.4 | 3.0 | False | None | None | False | None | False | 14434.2 | 0 |
3913505 | 150931 | None | APT118 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 mincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Cum | 517.0 | 517.0 | 14.0 | False | None | None | False | None | False | 7238.0 | 0 |
3913506 | 150931 | None | APT119 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm and class 3 including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Mtr | 433.4 | 433.4 | 25.0 | False | None | None | False | None | False | 10835.0 | 0 |