createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725619016666
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd350000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose27-09-2024 16:00:00
tenderQueryClose26-09-2024 16:00:00
technicalBidOpen30-09-2024 16:30:00
publishedDate20-09-2024 11:10:00
publishedByPostPWD_EE_DIV_HSPT
publishedByUserKPE10057 - DEVADASA T
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-09-2024 11:50:43
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonExecutive Engineer
splitEmdRequiredYnTrue
emdBankGuarantee250000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber080394200231
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1725619016702
version9
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT11950
titleCONSTRUCTION OF PRIMARY HEALTH CENTER AT THOOLAHALLI, KOTTURU TALUK, IN VIJAYANAGARA DISTRICTDMF 2023-24
descriptionCONSTRUCTION OF PRIMARY HEALTH CENTER AT THOOLAHALLI, KOTTURU TALUK, IN VIJAYANAGARA DISTRICT DMF 2023-24
categoryWORKS
categoryTextWorks
ecv23321060.59
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1694
locationNamePWD Division Office Hosapete
provisionalAmount30000000.0
groupOverheadTotal0.0
fileNumberPWD/2024-25/BD/DMF/PHC
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17256190170001NoneNoneBuildingsCivil works -Ground Floor17453138.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935477152093NoneCSR 2023-24 V-3 Page No 9 Item No 2.5A Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm412.65412.6515.91FalseNoneNoneFalseNoneFalse6565.26150
3935478152093NoneCSR 2023-24 V-1, Page No 8, Item No 1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & up-to depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up-to 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils up-to 300 mm depth.Cum99.7599.75477.3FalseNoneNoneFalseNoneFalse47610.6750
3935479152093NoneCSR 2023-24V-1, Page No 8, Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up-to 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils Depth up-to 3 mCum107.1107.1812.38FalseNoneNoneFalseNoneFalse87005.8980
3935480152093NoneCSR 2023-24 V-1, Page No 15, Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Cum6288.456288.45126.55FalseNoneNoneFalseNoneFalse795803.34750
3935481152093NoneCSR 2023-24 V-1, Page No 15, Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Cum6288.456288.4522.5FalseNoneNoneFalseNoneFalse141490.1250
3935482152093NoneCSR 2023-24 V-2, Page No 5, Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.9891.0FalseNoneNoneFalseNoneFalse110394.90
3935483152093NoneCSR 2023-24 V-1, Page No 7, Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up-to 1.5 m.Cum279.3279.3324.95FalseNoneNoneFalseNoneFalse90758.5350
3935484152093NoneCSR 2023-24 V-1, Page No 7, Item No 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum454.65454.65597.15FalseNoneNoneFalseNoneFalse271494.24750
3935485152093NoneCSR 2023-24 V-1, Page No 15, Item No 2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.8114.6FalseNoneNoneFalseNoneFalse762410.880
3935486152093NoneCSR 2023-24 V-1, Page No 16, Item No 2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6652.86652.819.3FalseNoneNoneFalseNoneFalse128399.040
3935487152093NoneCSR 2023-24 V-1, Page No 16, Item No 2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6804.06804.064.09FalseNoneNoneFalseNoneFalse436068.360
3935488152093NoneCSR 2023-24 V-1, Page No 18, Item No 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t93929.8593929.8513.18FalseNoneNoneFalseNoneFalse1237995.4230
3935489152093NoneCSR 2023-24 V-1, Page No 111, Item No 1Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Foundation up-to Plinth a.Isolated 8PERCENTCum532.22532.22114.59FalseNoneNoneFalseNoneFalse60987.08980
3935490152093NoneCSR 2023-24 V-1, Page No 111, Item No 3Form Work and CenteringPERCENT On Finished Rate of Concrete per CUM Foundation, Sub structure of Cross drainages -5 PERCENTCum314.42314.42126.51FalseNoneNoneFalseNoneFalse39777.27420
3935491152093NoneCSR 2023-24 V-1, Page No 111, Item No 9Form Work and Centering PERCENT On Finished Rate of Concrete per CUM RCC Columns Shaft (Slip Centering)-70%Cum4656.964656.9619.31FalseNoneNoneFalseNoneFalse89925.89760
3935492152093NoneCSR 2023-24 V-1, Page No 111, Item No 2Form Work and Centering On Finished Rate of Concrete per CUM Plinth Beams of Buildings 50 PERCENTCum3402.03402.030.35FalseNoneNoneFalseNoneFalse103250.70
3935493152093NoneCSR 2023-24 V-1, Page No 112, Item No 11Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Earth retaining structures -10 PERCENTCum680.4680.433.75FalseNoneNoneFalseNoneFalse22963.50
3935494152093NoneCSR 2023-24 V-1, Page No 16, Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.15177.66FalseNoneNoneFalseNoneFalse1276513.7490
3935495152093NoneCSR 2023-24 V-1, Page No 16, Item No 2.5.2)Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7257.07257.012.76FalseNoneNoneFalseNoneFalse92599.320
3935496152093NoneCSR 2023-24 V-1, Page No 111, Item No 9Form Work and Centering PERCENT On Finished Rate of Concrete per CUM RCC Columns / Shaft (Slip Centering)-70 PERCENTCum5029.615029.6122.75FalseNoneNoneFalseNoneFalse114423.62750
3935497152093NoneCSR 2023-24 V-1, Page No 111, Item No 9Form Work and Centering On Finished Rate of Concrete per CUM RCC Columns Shaft Slip Centering 70 PERCENTCum5079.95079.97.78FalseNoneNoneFalseNoneFalse39521.6220
3935498152093NoneCSR 2023-24 V-1, Page No112, Item No14Form Work and Centering PERCENT On Finished Rate of Concrete per CUM RCC Beams, Lintels & Troughs of Aqueducts-60 PERCENTCum4311.094311.0950.39FalseNoneNoneFalseNoneFalse217235.82510
3935499152093NoneCSR 2023-24 V-1, Page No112, Item No14Form Work and Centering On PERCENT Finished Rate of Concrete per CUM RCC Beams, Lintels & Troughs of Aqueducts-60 PERCENTCum4354.24354.22.16FalseNoneNoneFalseNoneFalse9405.0720
3935500152093NoneCSR 2023-24V-1, Page No 112, Item No 16Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Staircase and other similar structures 50 PERCENTCum3628.53628.5100.56FalseNoneNoneFalseNoneFalse364881.960
3935501152093NoneCSR 2023-24 V-1, Page No 112, Item No 16Form Work and Centering On Finished Rate of Concrete per CUM Chejjas Canopy Other Architectural projections of minor sections 45 PERCENTCum3233.323233.323.81FalseNoneNoneFalseNoneFalse12318.94920
3935502152093NoneCSR 2023-24 V-1, Page No 112, Item No 16Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Chejjas, Canopy & Other Architectural projections of minor sections -45 PERCENT Cum3265.653265.650.12FalseNoneNoneFalseNoneFalse391.8780
3935503152093NoneCSR 2023-24 V-1, Page No 18, Item No 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specificationt93929.8593929.8518.67FalseNoneNoneFalseNoneFalse1753670.29950
3935504152093NoneCSR 2023-24 V-1, Page No 18, Item No 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification.t94869.1594869.152.04FalseNoneNoneFalseNoneFalse193533.0660
3935505152093NoneCSR 2023-24 V-2, Page No 17, Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5957.63FalseNoneNoneFalseNoneFalse1317220.0650
3935506152093NoneCSR 2023-24 V-2, Page No 17, Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1389.261389.26196.71FalseNoneNoneFalseNoneFalse273281.33460
3935507152093NoneCSR 2023-24 V-2, Page No 17, Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.2136.59FalseNoneNoneFalseNoneFalse158335.1280
3935508152093NoneCSR 2023-24 V-2, Page No 100, ItemNo 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.17FalseNoneNoneFalseNoneFalse17638.47750
3935509152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.'-do- 40 mm thick both side TeakSqm5208.05208.08.64FalseNoneNoneFalseNoneFalse44997.120
3935510152093NoneCSR 2023-24 V-2, Page No 104, Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNos1066.81066.812.0FalseNoneNoneFalseNoneFalse12801.60
3935511152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete.Nos126.0126.04.0FalseNoneNoneFalseNoneFalse504.00
3935512152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. completeNos1169.71169.74.0FalseNoneNoneFalseNoneFalse4678.80
3935513152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeNos1104.61104.62.0FalseNoneNoneFalseNoneFalse2209.20
3935514152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete.(Nos248.85248.858.0FalseNoneNoneFalseNoneFalse1990.80
3935515152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. CompleteNos136.5136.58.0FalseNoneNoneFalseNoneFalse1092.00
3935516152093NoneCSR 2023-24 V-2, Page No 105, Item No 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos57.7557.754.0FalseNoneNoneFalseNoneFalse231.00
3935517152093NoneCSR 2023-24 V-2, Page No 107, Item No 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy typeNos288.75288.7516.0FalseNoneNoneFalseNoneFalse4620.00
3935518152093NoneCSR 2023-24 V-2, Page No 107, Item No 12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos303.45303.452.0FalseNoneNoneFalseNoneFalse606.90
3935519152093NoneCSR 2023-24 V-2, Page No 69, Item No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos63.063.08.0FalseNoneNoneFalseNoneFalse504.00
3935520152093NoneCSR 2023-24 V-2, Page No 205, Item No 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specificationsm54.654.616.8FalseNoneNoneFalseNoneFalse917.280
3935521152093NoneCSR 2023-24 V-2, Page No 110, Item No 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.748.6FalseNoneNoneFalseNoneFalse343636.020
3935522152093NoneCSR 2023-24 V-2, Page No 110, Item No 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7141.417141.411.8FalseNoneNoneFalseNoneFalse12854.5380
3935523152093NoneCSR 2023-24 V-2, Page No 109, Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6004.956004.952.88FalseNoneNoneFalseNoneFalse17294.2560
3935524152093NoneCSR 2023-24 V-2, Page No 104, Item No 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.)m333.9333.974.1FalseNoneNoneFalseNoneFalse24741.990
3935525152093NoneCSR 2023-24 V-2, Page No 104, Item No 12.55.1)Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamSqm2484.32484.320.48FalseNoneNoneFalseNoneFalse50878.4640
3935526152093NoneCSR 2023-24 V-2, Page No 111, Item No 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6557.256557.2540.95FalseNoneNoneFalseNoneFalse268519.38750
3935527152093NoneCSR 2023-24 V-2, Page No 86, Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.41081.08FalseNoneNoneFalseNoneFalse190702.5120
3935528152093NoneCSR 2023-24 V-2, Page No 86, Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg178.16178.1637.8FalseNoneNoneFalseNoneFalse6734.4480
3935529152093NoneCSR 2023-24 V-2, Page No 87, Item No 11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg523.95523.9537.8FalseNoneNoneFalseNoneFalse19805.310
3935530152093NoneCSR 2023-24 V-2, Page No 47, Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm52.552.551.48FalseNoneNoneFalseNoneFalse2702.70
3935531152093NoneCSR 2023-24 V-2, Page No 47, Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm53.0353.031.8FalseNoneNoneFalseNoneFalse95.4540
3935532152093NoneCSR 2023-24 V-2, Page No 48, Item No 8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm175.35175.3551.48FalseNoneNoneFalseNoneFalse9027.0180
3935533152093NoneCSR 2023-24 V-2, Page No 48, Item No 8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm177.1177.11.8FalseNoneNoneFalseNoneFalse318.780
3935534152093NoneCSR 2023-24 V-2, Page No 47, Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.658.64FalseNoneNoneFalseNoneFalse480.8160
3935535152093NoneCSR 2023-24 V-2, Page No 54, Item No 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)Sqm710.85710.858.64FalseNoneNoneFalseNoneFalse6141.7440
3935536152093NoneCSR 2023-24 V-2, Page No 85, Item No 11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25372.6FalseNoneNoneFalseNoneFalse221044.950
3935537152093NoneCSR 2023-24 V-2, Page No 41, Item No 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.752281.29FalseNoneNoneFalseNoneFalse610815.39750
3935538152093NoneCSR 2023-24 V-2, Page No 41, Item No 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm270.43270.43210.26FalseNoneNoneFalseNoneFalse56860.61180
3935539152093NoneCSR 2023-24 V-2, Page No 42, Item No 8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm384.3384.3491.75FalseNoneNoneFalseNoneFalse188979.5250
3935540152093NoneCSR 2023-24 V-2, Page No 42, Item No 8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm388.14388.14212.96FalseNoneNoneFalseNoneFalse82658.29440
3935541152093NoneCSR 2023-24 V-2, Page No 43, Item No 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-ChargeKg67.267.2983.5FalseNoneNoneFalseNoneFalse66091.20
3935542152093NoneCSR 2023-24 V-2, Page No 43, Item No 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-ChargeKg67.8767.87425.92FalseNoneNoneFalseNoneFalse28907.19040
3935543152093NoneCSR 2023-24 V-2, Page No 41, Item No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75187.56FalseNoneNoneFalseNoneFalse58096.710
3935544152093NoneCSR 2023-24 V-2, Page No 65, Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1521.451521.45187.56FalseNoneNoneFalseNoneFalse285363.1620
3935545152093NoneCSR 2023-24 V-2, Page No 60, Item No 9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 4 1 cement 4 coarse sand), jointing with grey cement slurry 3.3 kgPER SQM including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1202.251202.25304.85FalseNoneNoneFalseNoneFalse366505.91250
3935546152093NoneCSR 2023-24 V-2, Page No 60, Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4548.2FalseNoneNoneFalseNoneFalse44992.290
3935547152093NoneCSR 2023-24 V-2, Page No 64, Item No 9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specificationsSqm5594.45594.4243.45FalseNoneNoneFalseNoneFalse1361956.680
3935548152093NoneCSR 2023-24 V-2, Page No 69, Item No 10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2Sqm4133.854133.8513.0FalseNoneNoneFalseNoneFalse53740.050
3935549152093NoneCSR 2023-24 V-2, Page No 69, Item No 10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2Sqm4175.194175.191.0FalseNoneNoneFalseNoneFalse4175.190
3935550152093NoneCSR 2023-24 V-2, Page No 69, Item No 10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m344.4344.45.0FalseNoneNoneFalseNoneFalse1722.00
3935551152093NoneCSR 2023-24 V-2, Page No 69, Item No 10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. completeEach620.55620.552.0FalseNoneNoneFalseNoneFalse1241.10
3935552152093NoneCSR 2023-24 V-2, Page No 63, Item No 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specificationsSqm4521.34521.330.0FalseNoneNoneFalseNoneFalse135639.00
3935553152093NoneCSR 2023-24 V-2, Page No 65, Item No 9.40Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specificationSqm978.6978.618.5FalseNoneNoneFalseNoneFalse18104.10
3935554152093NoneCSR 2023-24 V-2, Page No 33, Item No 7.54Providing & Fixing of Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm with Exposed GI Plain T24 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas. The Eco Friendly Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/ Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients.The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible as per BS:476 Part 4, Fire Performance: as per BS 476 Part-6 for Fire Propagation, as per BS 476 Part 7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1 d0, Thermal Conductivity K 0.048 to 0.050 w/m K as per ECBC code 2007, NRC (Noise Reductions Coefficient) 0.5 to 0.75 (Semi Perforated & Fully Perforated Tiles) as per IS 8225 1987, Sound Attenuation (STA) 30 32dB,Thickness of tile should be 15mm thick with 450 kg per cum density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kgper cum density in the center of the body, Light Reflectance greater than 85percent, Weight of material is 5 to 5.5 kg/per sqm and Suitable for Green Building application with InOrganic Recycled content of 46- 50 percent out of which 18-20 perent should be FLYASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12 The tiles Shall be laid on 24mm Wide T Sections Flanges colour white having rotary stitching on all T sections. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg per sqm. The T sections should have Galvanizing of 120 grams per sqm and need to be installed with Suspension system.Sqm1981.351981.35411.1FalseNoneNoneFalseNoneFalse814532.9850
3935555152093NoneCSR 2023-24 V-2, Page No 27, Item No 7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized at 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-chargeGI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20 percent perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleeceSqm1795.51795.548.2FalseNoneNoneFalseNoneFalse86543.10
3935556152093NoneCSR 2023-24 V-2, Page No 50, Item No 8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.Sqm105.0105.02896.3FalseNoneNoneFalseNoneFalse304111.50
3935557152093NoneCSR 2023-24 V-2, Page No 50, Item No 8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.Sqm106.05106.05228.26FalseNoneNoneFalseNoneFalse24206.9730
3935558152093NoneCSR 2023-24 V-2, Page No 51, Item No 8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.Sqm55.6555.652896.3FalseNoneNoneFalseNoneFalse161179.0950
3935559152093NoneCSR 2023-24 V-2, Page No 51, Item No 8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in chargeSqm56.2156.21228.26FalseNoneNoneFalseNoneFalse12830.49460
3935560152093NoneCSR 2023-24 V-2, Page No 50, Item No 8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeSqm115.5115.52896.3FalseNoneNoneFalseNoneFalse334522.650
3935561152093NoneCSR 2023-24 V-2, Page No 50, Item No 8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Sqm116.66116.66228.26FalseNoneNoneFalseNoneFalse26628.81160
3935562152093NoneCSR 2023-24 V-2, Page No 46, Item No 8.30Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two coat applied at 1.67 ltr per 10 sqm over and including priming coat of exterior primer applied at 2.20 kg per 10 sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm182.7182.7491.75FalseNoneNoneFalseNoneFalse89842.7250
3935563152093NoneCSR 2023-24 V-2, Page No 46, Item No 8.30Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two coat applied at 1.67 ltr per 10 sqm over and including priming coat of exterior primer applied at 2.20 kg per 10 sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm184.53184.53212.96FalseNoneNoneFalseNoneFalse39297.50880
3935564152093NoneCSR 2023-24 V-2, Page No 149, Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of C Bathroom cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400 percent and tensile strength greater than 2 MPa as per A S T M D412. The waterproofing membrane to be applied in 2 coats at 1.6 kg per sqm to achieve final DFT Dry Film Thickness of 1 mm including prime coat of epoxy primer at 150 g per sqm and protection with 120 gsqm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm857.85857.85540.0FalseNoneNoneFalseNoneFalse463239.00
3935565152093NoneCSR 2023-24 V-2, Page No 54, Item No 8.80Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depthm69.369.31845.0FalseNoneNoneFalseNoneFalse127858.50
3935566152093NoneCSR 2023-24 V-2, Page No 43, Item No 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster Mesh(m35.735.71845.0FalseNoneNoneFalseNoneFalse65866.50
3935567152093NoneCSR 2023-24 V-2, Page No 77, Item No 11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm4498.644498.642.52FalseNoneNoneFalseNoneFalse11336.57280
3935568152093NoneCSR 2021-22 V-2, Page No 44, Item No 8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargem8.48.4148.8FalseNoneNoneFalseNoneFalse1249.920
3935569152093NoneCSR 2021-22 V-2, Page No 44, Item No 8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m8.488.484.8FalseNoneNoneFalseNoneFalse40.7040
17256190170001NoneNoneBuildingsWATER SUPPLY & SANITARY WORKS619848.21
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935570152094NoneCSR 2023-24 V-2, Page No -131, Item No -14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach6275.856275.8511.0FalseNoneNoneFalseNoneFalse69034.350
3935571152094NoneCSR 2023-24 V-2, Page No -131, Item No -14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern Urinal Basin Each4676.74676.73.0FalseNoneNoneFalseNoneFalse14030.10
3935572152094NoneCSR 2023-24 V-2, Page No -136, Item No -14.34.1Providing and fixing toilet paper holder : C.P. brassEach638.4638.411.0FalseNoneNoneFalseNoneFalse7022.40
3935573152094NoneCSR 2023-24 V-2, Page No -117, Item No -13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos320.25320.2511.0FalseNoneNoneFalseNoneFalse3522.750
3935574152094NoneCSR 2023-24 V-2, Page No -70, Item No -10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.452.88FalseNoneNoneFalseNoneFalse8433.9360
3935575152094NoneCSR 2023-24 V-2, Page No -132, Item No -14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern WashBasin Each2689.052689.055.0FalseNoneNoneFalseNoneFalse13445.250
3935576152094NoneCSR 2023-24 V-2, Page No -134, Item No -14.11.2) Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink Nos5336.15336.12.0FalseNoneNoneFalseNoneFalse10672.20
3935577152094NoneCSR 2023-24-V-2, Page No -140, Item No -14.62)Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class a.EconomyNos2024.42024.42.0FalseNoneNoneFalseNoneFalse4048.80
3935578152094NoneCSR 2023-24-V-2, Page No -137, Item No -14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g Towel Rail Each520.8520.810.0FalseNoneNoneFalseNoneFalse5208.00
3935579152094NoneCSR 2023-24 V-2, Page No -120, Item No -13.22.2) Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos212.1212.121.0FalseNoneNoneFalseNoneFalse4454.10
3935580152094NoneCSR 2023-24 V-2, Page No -135, Item No -14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos850.5850.512.0FalseNoneNoneFalseNoneFalse10206.00
3935581152094NoneCSR 2023-24 V-2, Page No -136, Item No -14.32.2)Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm Mirror Each1068.91068.910.0FalseNoneNoneFalseNoneFalse10689.00
3935582152094NoneCSR 2023-24 V-2, Page No -136, Item No -14.29)Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap Each49.3549.3510.0FalseNoneNoneFalseNoneFalse493.50
3935583152094NoneCSR 2023-24 V-2, Page No -136, Item No -14.28.2.2)Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm96.696.612.0FalseNoneNoneFalseNoneFalse1159.20
3935584152094NoneCSR 2023-24 V-2, Page No -128, Item No -13.64.1)Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm303.45303.4537.0FalseNoneNoneFalseNoneFalse11227.650
3935585152094NoneCSR 2023-24 V-2, Page No -128, Item No -13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110Mm nominal dia pipesm404.25404.2526.0FalseNoneNoneFalseNoneFalse10510.50
3935586152094NoneCSR 2023-24 V-2, Page No -125, Item No -13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameterm305.55305.5520.0FalseNoneNoneFalseNoneFalse6111.00
3935587152094NoneCSR 2023-24 V-2, Page No -122, Item No -13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes Cold Water Supply m397.95397.9540.0FalseNoneNoneFalseNoneFalse15918.00
3935588152094NoneCSR 2023-24 V-2, Page No -122, Item No -13.32.3)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia pipes Cold Water Supply m500.85500.8543.0FalseNoneNoneFalseNoneFalse21536.550
3935589152094NoneCSR 2023-24 V-2, Page No -122, Item No -13.32.4)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc32 mm nominal dia pipesm584.85584.856.0FalseNoneNoneFalseNoneFalse3509.10
3935590152094NoneCSR 2023-24 V-2, Page No -123, Item No 13.33.5)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes Cold Water Supply- Down Take m500.85500.8520.0FalseNoneNoneFalseNoneFalse10017.00
3935591152094NoneCSR 2023-24 V-2, Page No -123, Item No -13.33.6)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, TERRACE FLOOR including cutting chases and making good the walls etc40 mm nominal dia Pipes TERRACE FLOOR m764.62764.62107.0FalseNoneNoneFalseNoneFalse81814.340
3935592152094NoneCSR 2023-24V-2, Page No -136, Item No -14.31)Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Bevelled Edge mirror Nos1281.01281.05.0FalseNoneNoneFalseNoneFalse6405.00
3935593152094NoneCSR 2023-24 V-2, Page No -123, Item No -13.34)Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.TERRACE FLOOR Ltr9.549.542000.0FalseNoneNoneFalseNoneFalse19080.00
3935594152094NoneCSR 2023-24 V-2, Page No -121, Item No -13.26)Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gNos105.0105.010.0FalseNoneNoneFalseNoneFalse1050.00
3935595152094NoneCSR 2023-24 V-2, Page No -117, Item No 13.5.3)Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore TERRACE FLOOR Nos352.09352.091.0FalseNoneNoneFalseNoneFalse352.090
3935596152094NoneCSR 2023-24 V-2, Page No -118, Item No 13.6.3.1)Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT Nos1018.081018.083.0FalseNoneNoneFalseNoneFalse3054.240
3935597152094NoneCSR 2023-24 V-5, Page No -133, Item No -11.15.5)Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos1590.751590.757.0FalseNoneNoneFalseNoneFalse11135.250
3935598152094NoneCSR 2023-24 V-5, Page No -133, Item No -11.15.6)Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS markFor50 mm dia GM (Copper alloy) Gate valvesNos1790.121790.122.0FalseNoneNoneFalseNoneFalse3580.240
3935599152094NoneCSR 2023-24 V-5, Page No -86, Item No -7.5.1)Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges No1675.591675.592.0FalseNoneNoneFalseNoneFalse3351.180
3935600152094NoneCSR 2023-24 V-2, Page No -123, Item No -13.37)Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.m328.8328.820.0FalseNoneNoneFalseNoneFalse6576.00
3935601152094NoneCSR 2023-24 V-5, Page No -126, Item No -16.15.1)Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top,with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4.Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia,Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.0 M depth & SFRC cover & frameNos30499.3530499.353.0FalseNoneNoneFalseNoneFalse91498.050
3935602152094NoneCSR 2023-24 V-2, Page No -124, Item No -13.39)Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos2710.052710.0510.0FalseNoneNoneFalseNoneFalse27100.50
3935603152094NoneCSR 2023-24 V-1, Page No -5, Item No -1.4.1)RAIN WATER HARVESTING Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 mCum254.1254.120.25FalseNoneNoneFalseNoneFalse5145.5250
3935604152094NoneCSR 2023-24 V-1, Page No -5, Item No -1.4.2)Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum271.95271.9520.25FalseNoneNoneFalseNoneFalse5506.98750
3935605152094NoneCSR 2023-24 V-2, Page No -175, Item No -17.1)Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1052.11052.110.56FalseNoneNoneFalseNoneFalse11110.1760
3935606152094NoneCSR 2023-24 V-2, Page No -175, Item No -17.2)Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-chargeCum1245.31245.310.56FalseNoneNoneFalseNoneFalse13150.3680
3935607152094NoneCSR 2023-24 V-2, Page No -175, Item No -17.3)Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-chargeCum1251.61251.610.56FalseNoneNoneFalseNoneFalse13216.8960
3935608152094NoneCSR 2023-24 V-2, Page No -175, Item No -17.4)Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-chargeCum1405.951405.9520.72FalseNoneNoneFalseNoneFalse29131.2840
3935609152094NoneCSR 2023-24 V-2, Page No -175, Item No -17.6.3)Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge.200 mm nominal size dia having minimum wall thickness 5.40 mmEngineer-in-charge.m1970.851970.856.0FalseNoneNoneFalseNoneFalse11825.10
3935610152094NoneCSR 2023-24 V-2, Page No -176, Item No -17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-chargehr972.3972.332.0FalseNoneNoneFalseNoneFalse31113.60
3935611152094NoneCSR 2023-24 V-2, Page No -176, Item No -17.9.3)Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm diaEach266.7266.76.0FalseNoneNoneFalseNoneFalse1600.20
3935612152094NoneCSR 2023-24 V-2, Page No -176, Item No -17.11.3)Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).200 mm diaEach300.3300.36.0FalseNoneNoneFalseNoneFalse1801.80
17256190170001NoneNoneBuildingsSeptic Tank with Soak pit332034.29
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935613152095NoneCSR 2023-24 V-3, Page No -9, Item No -2.5iiA)Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle100 Sqm412.65412.650.17FalseNoneNoneFalseNoneFalse70.15050
3935614152095NoneCSR 2023-24 V-1, Page No 8, Item No -1.14.1)-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 mCum107.1107.139.17FalseNoneNoneFalseNoneFalse4195.1070
3935615152095NoneCSR 2023-24 V-1, Page No 15, Item No -2.1.3)-Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.451.16FalseNoneNoneFalseNoneFalse7294.6020
3935616152095NoneCSR 2023-24 V-1, Page No 16, Item No -2.3.2)-Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.010.61FalseNoneNoneFalseNoneFalse72190.440
3935617152095NoneCSR 2023-24 V-1, Page No -112, Item No -11Form Work and Centering Earth retaining structures-10(On Finished Rate of Concrete per CUMCum680.4680.47.47FalseNoneNoneFalseNoneFalse5082.5880
3935618152095NoneCSR 2023-24 V-1, Page No 112, Item No -15-Form Work and Centering RCC Roof Slabs (50PERCENT) ( PERCENT On Finished Rate of Concrete per CUMCum3402.03402.03.14FalseNoneNoneFalseNoneFalse10682.280
3935619152095NoneCSR 2023-24 V-1, Page No -18, Item No -2.11a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t93929.8593929.851.44FalseNoneNoneFalseNoneFalse135258.9840
3935620152095NoneSR 2018-19,Item No-12.6.1KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos318.15318.1515.0FalseNoneNoneFalseNoneFalse4772.250
3935621152095NoneCSR 2023-24 V-2, Page No 150, Item No -15.5)-Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500 (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In chargeSqm635.25635.2553.41FalseNoneNoneFalseNoneFalse33928.70250
3935622152095NoneCSR 2023-24 V-2, Page No 42, Item No -8.5.2)-Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm366.45366.4553.41FalseNoneNoneFalseNoneFalse19572.09450
3935623152095NoneCSR 2023-24 V-2, Page No 176, Item No 17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, CompleteSqm974.4974.46.37FalseNoneNoneFalseNoneFalse6206.9280
3935624152095NoneCSR 2023-24 V-2, Page No 13, Item No 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9317.79317.71.6FalseNoneNoneFalseNoneFalse14908.320
3935625152095NoneCSR 2023-24 V-2, Page No 175, Item No 17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-chargeCum1052.11052.15.6FalseNoneNoneFalseNoneFalse5891.760
3935626152095NoneCSR 2023-24 V-2, Page No 175, Item No 17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-chargeCum1245.31245.35.6FalseNoneNoneFalseNoneFalse6973.680
3935627152095NoneCSR 2023-24 V-2, Page No 175, Item No 17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-chargeCum1251.61251.64.0FalseNoneNoneFalseNoneFalse5006.40
17256190170001NoneNoneBuildingsSump Tank246297.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935628152096NoneCSR 2023-24V-3, Page No 9, Item No -2.5iiAClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle100 Sqm412.65412.650.19FalseNoneNoneFalseNoneFalse78.40350
3935629152096NoneCSR 2023-24 V-1, Page No -8, Item No -1.14.1EXCAVATION Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 mCum107.1107.123.89FalseNoneNoneFalseNoneFalse2558.6190
3935630152096NoneCSR 2023-24 V-1, Page No 15, Item No -2.1.3-Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.39FalseNoneNoneFalseNoneFalse15029.39550
3935631152096NoneCSR 2023-24 V-1, Page No 16, Item No -2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Cum6804.06804.010.69FalseNoneNoneFalseNoneFalse72734.760
3935632152096NoneCSR 2023-24 V-1, Page No 112, Item No 11Form Work and Centering Earth retaining structures-10PECENT ( %On Finished Rate of Concrete per CUMCum680.4680.44.38FalseNoneNoneFalseNoneFalse2980.1520
3935633152096NoneCSR 2023-24 V-1, Page No 112, Item No -15Form Work and Centering RCC Roof Slabs (50%) ( % On Finished Rate of Concrete per CUMCum3402.03402.06.32FalseNoneNoneFalseNoneFalse21500.640
3935634152096NoneCSR 2023-24 V-1, Page No 18, Item No -2.11a-Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t93929.8593929.850.91FalseNoneNoneFalseNoneFalse85476.16350
3935635152096NoneSR 2018-19,Item No-12.6.1KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos318.15318.153.0FalseNoneNoneFalseNoneFalse954.450
3935636152096NoneCSR 2023-24 V-2, Page No 150, Item No -15.5-Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm635.25635.2544.6FalseNoneNoneFalseNoneFalse28332.150
3935637152096NoneCSR 2023-24 V-2, Page No 42, Item No- 8.6.1)-Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm339.15339.1549.1FalseNoneNoneFalseNoneFalse16652.2650
17256190170000NoneNoneBuildingsUPS WORKS482651.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935638152097NoneCSR 2023-24 V-6, Page No 38, Item No 9.3.5Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete.10 kVA ON LINE UPSEach108748.5108748.52.0FalseNoneNoneFalseNoneFalse217497.00
3935639152097NoneCSR 2023-24 V-6, Page No 38, Item No 9.3.5Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries.120 AH capacityEach16572.1516572.1516.0FalseNoneNoneFalseNoneFalse265154.40
17256190170000NoneNoneBuildingsEXTERNAL ELECTRIFICATION WORKS GESCOM639680.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935640152098NoneAS PER GESCOM DATARATEExternal Electrification works as per Gescom Data Sheet With GST IncludingRs639680.0639680.01.0FalseNoneNoneFalseNoneFalse639680.00
17256190170000NoneNoneBuildingsINTERNAL ELECTRIFICATION WORKS(PWD SR 2023-2024 / BESOM CSR 2023-2024)1785732.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935641152099NonePWD SR 23-24 V-6(ITEM NO:2.2.1)POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(Page 5)point wiring using class A Materials.Short point upto 3 mts from tapping point to out let via switch box Point282.45282.4555.0FalseNoneNoneFalseNoneFalse15534.750
3935642152099NonePWD SR 23-24V-6(ITEM NO:2.2.2)Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(Page 5)point wiring using class A Materials Medium point above 3 mts upto 6mts from tapping point to outlet via switch box Point397.95397.9563.0FalseNoneNoneFalseNoneFalse25070.850
3935643152099NonePWD SR 23-24V-6(ITEM NO:2.2.3)Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(Page 5)point wiring using class A Materials. PWD SR 23-24V-6(ITEM NO:2.2.3) Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(Page 5)point wiring using class A Materials. PWD SR 23-24V-6(ITEM NO:2.2.3) Long point above 6 mts upto 10 mts from tapping point to outlet via switch box Point582.75582.7576.0FalseNoneNoneFalseNoneFalse44289.00
3935644152099NonePWD SR 23-24V-6(ITEM NO:3.4.23WAYEach166.95166.9514.0FalseNoneNoneFalseNoneFalse2337.30
3935645152099NonePWD SR 23-24V-6(ITEM NO:3.4.46WAYEach231.0231.014.0FalseNoneNoneFalseNoneFalse3234.00
3935646152099NonePWD SR 23-24V-6(ITEM NO:3.4.58WAYEach274.05274.0520.0FalseNoneNoneFalseNoneFalse5481.00
3935647152099NonePWD SR 23-24V-6(ITEM NO:3.4.610-12WAYEach334.95334.9534.0FalseNoneNoneFalseNoneFalse11388.30
3935648152099NonePWD SR 23-24V-6(ITEM NO:3.5.23MODULEEach169.05169.0514.0FalseNoneNoneFalseNoneFalse2366.70
3935649152099NonePWD SR 23-24V-6(ITEM NO:3.5.46 MODULEEach245.7245.714.0FalseNoneNoneFalseNoneFalse3439.80
3935650152099NonePWD SR 23-24V-6(ITEM NO:3.5.58 MODULEEach298.2298.220.0FalseNoneNoneFalseNoneFalse5964.00
3935651152099NonePWD SR 23-24V-6(ITEM NO:3.5.610-12MODULEEach361.2361.234.0FalseNoneNoneFalseNoneFalse12280.80
3935652152099NonePWD SR 23-24V-6(ITEM NO:3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch Each107.1107.1289.0FalseNoneNoneFalseNoneFalse30951.90
3935653152099NonePWD SR 23-24V-6(ITEM NO:3.6.36 amps 3 way switchEach179.55179.55107.0FalseNoneNoneFalseNoneFalse19211.850
3935654152099NonePWD SR 23-24V-6(ITEM NO:3.6.4stepped fan Regulator's Each374.85374.8548.0FalseNoneNoneFalseNoneFalse17992.80
3935655152099NonePWD SR 23-24V-6(ITEM NO:3.6.106/16 Amps universal sockets Each247.8247.87.0FalseNoneNoneFalseNoneFalse1734.60
3935656152099NonePWD SR 23-24V-6(ITEM NO:3.6.716A one way switch Each189.0189.07.0FalseNoneNoneFalseNoneFalse1323.00
3935657152099NonePWD SR 23-24V-6(ITEM NO:3.6.932A DP switch Each342.3342.313.0FalseNoneNoneFalseNoneFalse4449.90
3935658152099NonePWD SR 23-24V-6(ITEM NO:3.6.86A Bell push Each185.85185.852.0FalseNoneNoneFalseNoneFalse371.70
3935659152099NonePWD SR 23-24V-6(ITEM NO:12.2.1)Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote Ding Donng bell Each258.3258.32.0FalseNoneNoneFalseNoneFalse516.60
3935660152099NonePWD SR 23-24V-6(ITEM NO:13.12)Extra length of GI pipe of class B 19mm dia for down rod.Each206.85206.8540.0FalseNoneNoneFalseNoneFalse8274.00
3935661152099NonePWD SR 23-24V-6(ITEM NO:1.13)Supply and fixing one metal Fan box with round hookEach122.85122.8548.0FalseNoneNoneFalseNoneFalse5896.80
3935662152099NonePWD SR 23-24V-6(ITEM NO:1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick Mtr69.369.3725.0FalseNoneNoneFalseNoneFalse50242.50
3935663152099NonePWD SR 23-24V-6(ITEM NO:1.2.225 mm dia 2mm thick Mtr81.981.9550.0FalseNoneNoneFalseNoneFalse45045.00
3935664152099NonePWD SR 23-24V-6(ITEM NO:1.2.332 mm dia 2.5mm thick Mtr108.15108.15210.0FalseNoneNoneFalseNoneFalse22711.50
3935665152099NonePWD SR 23-24V-6(ITEM NO:1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick Mtr71.471.4195.0FalseNoneNoneFalseNoneFalse13923.00
3935666152099NonePWD SR 23-24V-6(ITEM NO:1.3.225 mm dia 2mm thick Mtr82.9582.95260.0FalseNoneNoneFalseNoneFalse21567.00
3935667152099NonePWD SR 23-24V-6(ITEM NO:1.3.3)32 mm dia 2mm thick Mtr103.95103.9530.0FalseNoneNoneFalseNoneFalse3118.50
3935668152099NonePWD SR 23-24V-6(ITEM NO:1.5.1)Supplying and fixing PVC/metal conduit deep junction box 19/20mm deep junction box Each51.4551.4595.0FalseNoneNoneFalseNoneFalse4887.750
3935669152099NonePWD SR 23-24V-6(ITEM NO:1.5.2)25mm deep junction box Each58.858.8105.0FalseNoneNoneFalseNoneFalse6174.00
3935670152099NonePWD SR 23-24V-6(ITEM NO:1.5.3)32mm deep junction box Each64.0564.0515.0FalseNoneNoneFalseNoneFalse960.750
3935671152099NonePWD SR 23-24V-6(ITEM NO:2.3.2)TOTAL OF POINT WIRING WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm Mtr27.327.32800.0FalseNoneNoneFalseNoneFalse76440.00
3935672152099NonePWD SR 23-24V-6(ITEM NO:2.3.3)2.5 sq.mm Mtr44.144.11850.0FalseNoneNoneFalseNoneFalse81585.00
3935673152099NonePWD SR 23-24V-6(ITEM NO:2.3.4)4 sq.mm Mtr66.1566.15550.0FalseNoneNoneFalseNoneFalse36382.50
3935674152099NonePWD SR 23-24V-6(ITEM NO:2.3.5)6sq.mm Mtr96.696.6175.0FalseNoneNoneFalseNoneFalse16905.00
3935675152099NonePWD SR 23-24V-6(ITEM NO:2.3.610sq.mm Mtr175.35175.35110.0FalseNoneNoneFalseNoneFalse19288.50
3935676152099NonePWD SR 23-24V-6(ITEM NO:5.19.9)12 Way TP & N Each2445.452445.454.0FalseNoneNoneFalseNoneFalse9781.80
3935677152099NonePWD SR 23-24V-6(ITEM NO:5.18.1)Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP Each435.75435.7535.0FalseNoneNoneFalseNoneFalse15251.250
3935678152099NonePWD SR 23-24V-6(ITEM NO:5.18.5)40 A DPEach1113.01113.010.0FalseNoneNoneFalseNoneFalse11130.00
3935679152099NonePWD SR 23-24V-6(ITEM NO:5.18.9)50-63 A TPNEach3242.43242.48.0FalseNoneNoneFalseNoneFalse25939.20
3935680152099NonePWD SR 23-24V-6(ITEM NO:5.20.4)Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 32-40Amps 2 pole Each4786.954786.953.0FalseNoneNoneFalseNoneFalse14360.850
3935681152099NonePWD SR 23-24V-6(ITEM NO:5.20.10)63Amps 4 pole Each5822.255822.252.0FalseNoneNoneFalseNoneFalse11644.50
3935682152099NonePWD SR 23-24V-6 ITEM NO:5.17Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2, 12 Way Each16305.4516305.451.0FalseNoneNoneFalseNoneFalse16305.450
3935683152099NonePWD SR 23-24V-6(ITEM NO 5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 2, 100 A 25 kA Each8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3935684152099NonePWD SR 23-24V-6(ITEM NO:5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A Each4407.824407.821.0FalseNoneNoneFalseNoneFalse4407.820
3935685152099NonePWD SR 23-24V-6(ITEM NO:5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour 100A Each7949.557949.552.0FalseNoneNoneFalseNoneFalse15899.10
3935686152099NonePWD SR 23-24V-6(ITEM NO:11.3.2Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factorgreater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 20/22 W Each724.5724.587.0FalseNoneNoneFalseNoneFalse63031.50
3935687152099NonePWD SR 23-24V-6(ITEM NO:11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor greater than 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working understandard electrical condition LED square or round down light 15-18W Each1390.21390.215.0FalseNoneNoneFalseNoneFalse20853.00
3935688152099NonePWD SR 23-24V-6(ITEM NO:11.6.3Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI greater than 70 percent. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5 perecent of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2'-34-36W No4780.654780.6514.0FalseNoneNoneFalseNoneFalse66929.10
3935689152099NoneWD SR 2023-24, Chapter 11 I.No. 11.11.4 Retrofit type LED Bulb (PWD SR 2023-24, Chapter 11 I.No. 11.11.4) 9W 6500K 9W 6500KEach161.7161.712.0FalseNoneNoneFalseNoneFalse1940.40
3935690152099NonePWD SR 23-24V-6(ITEM NO:6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC SupplyEach1566.61566.613.0FalseNoneNoneFalseNoneFalse20365.80
3935691152099NonePWD SR 23-24V-6(ITEM NO:6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm) Each2810.852810.8548.0FalseNoneNoneFalseNoneFalse134920.80
3935692152099NonePWD SR 23-24V-6(ITEM NO:13.7.1)Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each128.1128.1102.0FalseNoneNoneFalseNoneFalse13066.20
3935693152099NonePWD SR 23-24V-6(ITEM NO:13.10)Fixing a ceiling / Wall mounting fan of all capacities and alltypes to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose,necessary length of 23 / 0.0076 inch PVC insulated twintwisted copper wire and wiring.Each179.55179.5548.0FalseNoneNoneFalseNoneFalse8618.40
3935694152099NonePWD SR 23-24V-6(ITEM NO:13.10Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each516.6516.613.0FalseNoneNoneFalseNoneFalse6715.80
3935695152099NonePWD SR 23-24V-6(ITEM NO:5.42.1TOTAL OF ELECTRICAL FIXTURE CONTROL SWITCH GEARS & ACCESSORIES MAIN LT PANEL Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking rrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG Sq CM0.530.53110000.0FalseNoneNoneFalseNoneFalse58300.00
3935696152099NonePWD SR 23-24V-6(ITEM NO:5.40.2)Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium StripsMtr3606.753606.757.0FalseNoneNoneFalseNoneFalse25247.250
3935697152099NonePWD SR 23-24V-6(ITEM NO:5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Mtr320.25320.2516.0FalseNoneNoneFalseNoneFalse5124.00
3935698152099NonePWD SR 23-24V-6(ITEM NO:5.18.5)Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP Each1113.01113.05.0FalseNoneNoneFalseNoneFalse5565.00
3935699152099NonePWD SR 23-24V-6(ITEM NO:5.18.950-63 A TPNEach3242.43242.45.0FalseNoneNoneFalseNoneFalse16212.00
3935700152099NonePWD SR 23-24V-6(ITEM NO:5.15.9125 A 25 KAEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3935701152099NonePWD SR 23-24V-6(ITEM NO:5.38)Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3935702152099NonePWD SR 23-24V-6(ITEM NO:5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood boardEach540.75540.751.0FalseNoneNoneFalseNoneFalse540.750
3935703152099NonePWD SR 23-24V-6(ITEM NO: 5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3935704152099NonePWD SR 23-24V-6(ITEM NO: 5.26)Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach504.0504.03.0FalseNoneNoneFalseNoneFalse1512.00
3935705152099NonePWD SR 23-24V-6(ITEM NO: 5.27)Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach210.0210.01.0FalseNoneNoneFalseNoneFalse210.00
3935706152099NonePWD SR 23-24V-6(ITEM NO:5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3935707152099NonePWD SR 23-24V-6(ITEM NO:5.29)Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
3935708152099NonePWD SR 23-24V-6(ITEM NO:2.3.2)WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 mm2 Mtr27.327.360.0FalseNoneNoneFalseNoneFalse1638.00
3935709152099NonePWD SR 23-24V-6(ITEM NO:2.3.3)Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with 2.5 mm2 specified IS-694:confirming to latest amendments. 2.5 mm2 Mtr44.144.145.0FalseNoneNoneFalseNoneFalse1984.50
3935710152099NonePWD SR 23-24V-6(ITEM NO:2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with 16 mm2 specified IS-694:confirming to latest amendments. 16 mm2 Mtr333.9333.955.0FalseNoneNoneFalseNoneFalse18364.50
3935711152099NonePWD SR 23-24V-6(ITEM NO:5.42.1)APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made outSWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG Sq CM0.530.5380000.0FalseNoneNoneFalseNoneFalse42400.00
3935712152099NonePWD SR 23-24V-6(ITEM NO:5.39)Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach22722.022722.01.0FalseNoneNoneFalseNoneFalse22722.00
3935713152099NonePWD SR 23-24V-6(ITEM NO:5.40.2)Supplying . A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips Mtr3606.753606.754.0FalseNoneNoneFalseNoneFalse14427.00
3935714152099NonePWD SR 23-24V-6(ITEM NO:5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism THREE Pole.Incomers 160 A 25 kA Each8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3935715152099NonePWD SR 23-24V-6(ITEM NO:5.15.14)THREEOut Goings Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism 16 - 32 A TP Each842.1842.18.0FalseNoneNoneFalseNoneFalse6736.80
3935716152099NonePWD SR 23-24V-6(ITEM NO: 5.41.1)Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Mtr320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3935717152099NonePWD SR 23-24V-6(ITEM NO:5.4.2)Fixing a shunt capacitor of . kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR Each224.7224.74.0FalseNoneNoneFalseNoneFalse898.80
3935718152099NonePWD SR 23-24V-6(ITEM NO:5.4.3)11 to 20 kVAR Each361.2361.21.0FalseNoneNoneFalseNoneFalse361.20
3935719152099NonePWD SR 23-24V-6(ITEM NO:5.13.1)Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25AEach1354.51354.56.0FalseNoneNoneFalseNoneFalse8127.00
3935720152099NonePWD SR 23-24V-6(ITEM NO:5.18.1)Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP Each435.75435.753.0FalseNoneNoneFalseNoneFalse1307.250
3935721152099NonePWD SR 23-24V-6(ITEM NO:5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.CEach540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3935722152099NonePWD SR 23-24V-6(ITEM NO:5.34)Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach590.1590.13.0FalseNoneNoneFalseNoneFalse1770.30
3935723152099NonePWD SR 23-24V-6(ITEM NO:2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest endmentsAutomatic APFCR with controller along with colling Fans and Interlocking,1.5 mm2 Mtr27.327.340.0FalseNoneNoneFalseNoneFalse1092.00
3935724152099NonePWD SR 23 24 V-6 ITEM NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendmentsAutomatic APFCR with controller along with colling Fans and Interlocking.2.5 mm2 Mtr44.144.145.0FalseNoneNoneFalseNoneFalse1984.50
3935725152099NonePWD SR 23-24V-6(ITEM NO:2.3.4)Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest mendmentsAutomatic APFCR with controller along with colling Fans and Interlocking.4 mm2 Mtr66.1566.1535.0FalseNoneNoneFalseNoneFalse2315.250
3935726152099NonePWD SR 23-24V-6(ITEM NO:2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendmentsAutomatic APFCR with controller along with colling Fans and Interlocking.Mtr333.9333.915.0FalseNoneNoneFalseNoneFalse5008.50
3935727152099NonePWD SR 23-24V-6 (ITEM NO:32.11upplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975,50 Sqmm, 3.5 Core. Km187921.65187921.650.08FalseNoneNoneFalseNoneFalse15033.7320
3935728152099NonePWD SR 23-24V-6(ITEM NO:21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff(PWD SR 23-24V-6(ITEM NO:21.05)LT CABLE 35 to 95 Sqmm Km32695.9532695.950.08FalseNoneNoneFalseNoneFalse2615.6760
3935729152099NonePWD SR 23-24 V-6 Sl No.510 I.NO.63.04 P.No.28 oF81Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11),45mm dia Each206.85206.851.0FalseNoneNoneFalseNoneFalse206.850
3935730152099NonePWD SR 23-24V-6 Sl No.459 P.No.26 of 81 INO:59.03Heavy Duty Copper Terminal Long Barrel,50 Sqmm Copper Terminal, Apprx Wt: 17 Gm No60.960.98.0FalseNoneNoneFalseNoneFalse487.20
3935731152099NonePWD SR 23-24V-6(ITEM NO:12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm,Using 4ft. Copper bonded rod with backfill compound. Each4754.44754.42.0FalseNoneNoneFalseNoneFalse9508.80
3935732152099NonePWD SR 23-24V-6(ITEM NO:5.34Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each3685.53685.52.0FalseNoneNoneFalseNoneFalse7371.00
3935733152099NonePWD SR 23-24V-6(ITEM NO:12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600x600x3mm Copper plate Each7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3935734152099NonePWD SR 23-24V-6(ITEM NO: 6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc8 SWG GI Wire Mtr19.9519.9560.0FalseNoneNoneFalseNoneFalse1197.00
3935735152099NonePWD SR 23-24 V-6 ITEM NO: 6.8.5 P.No.31 of 105Supplyingof.TRInvertortypesplitAirconditionerssuitableforoperationonA/Csupplysinglephase50Hz230Vwithhermeticallysealedinvertercompressorwithaircooledcondenser,latestR410A/R-32refrigerantfanmotor,start&runcapacitors,relay&overloadprotectorinternalunit,withoneindoor&oneoutdoorunitThecondenserunitwillbeplacedoutsidetheroomavoidnoiseincludingstandardlengthofsuitablesizecoppertubingcoveredwithnitrilerubberinsulationtube.suitablecapacity3coresheathed/PVCcopper cable and a battery operated wireless remote unit.1.5 Ton capacity Each59151.7559151.754.0FalseNoneNoneFalseNoneFalse236607.00
3935736152099NonePWD SR 23-24 V-6 ITEM NO 6.12 P.No.32 of 105InstallationchargesforsplittypeairconditionerwithalliedworksforoneindoorandoneoutdoorunitistobemountedonsuitableAngleIron support upto 3.0 Ton split/cassette type A/CEach3333.753333.754.0FalseNoneNoneFalseNoneFalse13335.00
3935737152099NoneWD SR 23-24 V-6 ITEM NO 6.22 P.No.32 of 105ExtraforFabricationsupplyandfixingofStandfabricatedusingslottedangle/Langleofsize6mmx50mmformountingoutdoor/indoor A.C. unit/ Batteries.4kVA Capacity Each5047.355047.354.0FalseNoneNoneFalseNoneFalse20189.40
3935738152099NonePWD SR 23-24 V-6 ITEM NO 9.1.2 P.No.38 of 105Supplying,erecting,testingandcommissioningofvoltagestabilizersuitablefor170to270vinputandloadvariationfromnoloadtofullload,withoverloadprotection,spikesuppression,operatingat00Cto 400 C. Range etc., complete.4kVA Capacity Each5031.65031.64.0FalseNoneNoneFalseNoneFalse20126.40
3935739152099NoneSR V-6 P.NO.45 46 OF 105 I.NO.11.8.5LED Streetlight 120 W Each10563.010563.06.0FalseNoneNoneFalseNoneFalse63378.00
3935740152099NoneSR V-6 P.NO. 56 OF 105I.NO.13.2.2Using 32mm dia G.I.Pipe Each1359.751359.756.0FalseNoneNoneFalseNoneFalse8158.50
3935741152099NoneSR V-6 P.NO.56 OF105,I.NO.13.5Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires.Each170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
17256190170000NoneNoneBuildingsCC Road works1761679.09
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3935742152100NoneCSR 2023-24 V-3, Page No 9, Item No 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm412.65412.654.52FalseNoneNoneFalseNoneFalse1865.1780
3935743152100NoneCSR 2023-24 V-1, Page No 8, Item No 1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum99.7599.75135.6FalseNoneNoneFalseNoneFalse13526.10
3935744152100NoneCSR 2023-24 V-3, Page No17, Item No 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum110.25110.25135.6FalseNoneNoneFalseNoneFalse14949.90
3935745152100NoneCSR 2023-24 V-1, Page No 7, Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum497.7497.7135.6FalseNoneNoneFalseNoneFalse67488.120
3935746152100NoneCSR 2023-24V-3, Page No 23, Item No 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401Cum2476.952476.95135.6FalseNoneNoneFalseNoneFalse335874.420
3935747152100NoneCSR 2023-24 V-3, Page No 49, Item No 6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum5166.05166.067.8FalseNoneNoneFalseNoneFalse350254.80
3935748152100NoneCSR 2023-24V-3, Page No 49, Item No 6.2.1Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum9514.059514.0590.4FalseNoneNoneFalseNoneFalse860070.120
3935749152100NoneCSR 2023-24 V-3,Page No 66, Item No 8.10Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm114.45114.4516.95FalseNoneNoneFalseNoneFalse1939.92750
3935750152100NoneCSR 2023-24 V-3, Page No 123, Item No 13.14Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2Sqm88.288.2450.0FalseNoneNoneFalseNoneFalse39690.00
3935751152100NoneCSR 2023-24 V-3, Page No 74, Item No 8.42.1Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)m318.15318.15150.0FalseNoneNoneFalseNoneFalse47722.50
3935752152100NoneCSR 2023-24 V-1, Page No 15, Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.454.5FalseNoneNoneFalseNoneFalse28298.0250
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17256190180000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17256190180000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17256190180001NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17256190180000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17256190180000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17258623280000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17258623340000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17258623380000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17258623420000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17258623490000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17258623530000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year(both days inclusive).None
17258623590000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17258623670000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17258623710000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17258623750000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPP-PortalNone
17258623800000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17258623840000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17258623900000NoneNoneELIGIBILITYAs per circular of Govt. of Karnataka Government Order No. PWD 107 CRM 2013, Bangalore, Dated: 20.02.2014, If the tenderer uploads the Bank Guarantee, but does not produce original at the time of technical scrutiny, such tenders will not be disqualified either in the technical bid stage or financial bid stage. But the qualified tenderer (L1) must submit the original copy of the BG at the time of agreement.None
17258623940000NoneNoneELIGIBILITYThe contractor shall bound to comply the prevailing rules and regulations with regard to the EPF rules and any modifications before and after execution of agreementNone
17258623990000NoneNoneELIGIBILITYAfter the award of the contract, the contractor has to furnish the details in respect of labour employed and the EPF details for this work in every RA bill.None
17258624050000NoneNoneELIGIBILITYThe Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17258624110000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17258624180000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17258624260000NoneNoneELIGIBILITYThe star rates inrespect of specified materials ( Cement, Steel and Bitumen) shall be payable as per CIRCULAR NO.PWD 159 CRM 2009 Bangalore Dated 30.09.2010None
17258624320000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next section.None
17258624510000NoneNoneELIGIBILITYThe work should be completed in 11(Eleven) Months ( including monsoon)None
17258624640000NoneNoneELIGIBILITYThe earnest money deposit shall be in two parts i.e.,Part (1) Rs.1,00,000by e.payment and balance Part (2) Rs. Balance amount as specified in the KPP portal shall be in the form of Bank Guarantee in the prescribed format obtained from the Nationalized / Schedule Bank FDR or specified small savings instrument pledged to the Executive Engineer, Public Works Department Division, HOSAPETE payable at HOSAPETE before the prescribed date and time of opening of Technical Bid without failNone
17258624690000NoneNoneELIGIBILITYAny dispute or difference or claim arising out of, or in connection with, or relating to the present contract or the breach, termination or invalid thereof shall be referred and settled under the Arbitration centre Karnataka (Domastic and international Rules 2012,by one or more arbitratiors appointed in accordance with its rulesNone
17258624740000NoneNoneELIGIBILITYThe deffect liability period is one year (1Year)from the date of actual completion of work.None
17258624780000NoneNoneELIGIBILITY18%GST Will paid extra to the executed quantitesNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 & 2023-24 b) Executed in any one year, the following minimum quantities of work 1 Earth work /Embankment/Sub Grade/Shoulder 2036.00 Cum 2.CC/PCC/RCC/DLC 581.00Cum 3.Steel 30.10Tonnes 4.Flooring 519.00 Sqm 5.SSM/BBM/Solid bricks 210.00 Cum 6.Plastering 2790.00 7. Gsb 109.00 cumPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 &2023-24 b) Satisfactorily completed, as prime contractor, at least one similar work such as Building Work of value not less than Rs.116.60 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.2019-20, 2020-21 2021-22, 2022-23 &2023-24 a) Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 466.42 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid Assets and /or availability of credit facilities of no less than Rs.63.60lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etc.,Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration CertificateTrueTechnical Bid
Annual Turnover Certificate Not below the rank of Charterd Accountant,The bidder should mention the UDIN NoTrueTechnical Bid
Single Work Done Certificate Not Below the rank of Executive Engineer/Work indent should be mentionedTrueTechnical Bid
Quantity Wise Work Done Certificate/Work indent should be mentionedTrueTechnical Bid
Liquid AssetsTrueTechnical Bid
GST CERTIFICATETrueTechnical Bid
Principal Place of Business.TrueTechnical Bid
Tender Bid CapacityTrueTechnical Bid
List of Existing commitments & Ongoing works- Format-5TrueTechnical Bid
List of works for which tenders acceptence letter received-Format-6TrueTechnical Bid
List of works for which tenders already submitted-Format-7TrueTechnical Bid
Profit and loss ac & Balance sheets for 5 yearsTrueTechnical Bid
Income Tax returns for 5 yearsTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725863199000
version0
createdDateNone
modifiedDateNone
blockNumberOffice Of the Executive Engineer, PWD Division, Behind S.P Office,Dam Road, Hosapete
streetNone
cityHosapete
stateKarnataka
pin583201
tenderRecallDTONone