4034198 | 156506 | None | code01 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 5664.0 | 5664.0 | 10.24 | False | None | None | False | None | False | 57999.36 | 0 |
4034199 | 156506 | None | code02 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings & with all lead & lifts and as per direction of the Engineer in charge of work. | t | 89457.0 | 89457.0 | 2.64 | False | None | None | False | None | False | 236166.48 | 0 |
4034200 | 156506 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 6287.0 | 6287.0 | 9.05 | False | None | None | False | None | False | 56897.35 | 0 |
4034201 | 156506 | None | code04 | Centering charges for Footing& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 503.0 | 503.0 | 4.86 | False | None | None | False | None | False | 2444.58 | 0 |
4034202 | 156506 | None | code05 | Centering charges for Columns& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 4401.0 | 4401.0 | 4.19 | False | None | None | False | None | False | 18440.19 | 0 |
4034203 | 156506 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 5611.0 | 5611.0 | 23.66 | False | None | None | False | None | False | 132756.26 | 0 |
4034204 | 156506 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 6389.0 | 6389.0 | 9.01 | False | None | None | False | None | False | 57564.89 | 0 |
4034205 | 156506 | None | code08 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works ofbridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 6336.0 | 6336.0 | 4.23 | False | None | None | False | None | False | 26801.28 | 0 |
4034206 | 156506 | None | code09 | Centering charges for Plinth& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 3168.0 | 3168.0 | 4.23 | False | None | None | False | None | False | 13400.64 | 0 |
4034207 | 156506 | None | code10 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 8661.0 | 8661.0 | 30.04 | False | None | None | False | None | False | 260176.44 | 0 |
4034208 | 156506 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarseaggregates & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 6630.0 | 6630.0 | 17.24 | False | None | None | False | None | False | 114301.2 | 0 |
4034209 | 156506 | None | code12 | Centering charges for Lintel and Beam& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 3978.0 | 3978.0 | 4.71 | False | None | None | False | None | False | 18736.38 | 0 |
4034210 | 156506 | None | code13 | Centering charges for Roof& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 1193.4 | 1193.4 | 11.34 | False | None | None | False | None | False | 13533.156 | 0 |
4034211 | 156506 | None | code14 | Centering charges for Chajja& with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 2983.5 | 2983.5 | 0.47 | False | None | None | False | None | False | 1402.245 | 0 |
4034212 | 156506 | None | code15 | Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
19/20 mm dia 2 mm thick& with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 61.0 | 61.0 | 28.0 | False | None | None | False | None | False | 1708.0 | 0 |
4034213 | 156506 | None | code16 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thick 19/20 mm dia 2 mm thick& with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 75.0 | 75.0 | 28.0 | False | None | None | False | None | False | 2100.0 | 0 |
4034214 | 156506 | None | code17 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 135 x 75 x 65 mm& with all lead & lifts and as per direction of the Engineer in charge of work. | No | 262.0 | 262.0 | 2.0 | False | None | None | False | None | False | 524.0 | 0 |
4034215 | 156506 | None | code18 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 200 x 200 x 65 mm& with all lead & lifts and as per direction of the Engineer in charge of work. | No | 335.0 | 335.0 | 2.0 | False | None | None | False | None | False | 670.0 | 0 |
4034216 | 156506 | None | code19 | Supplying and fixing PVC/metal conduit Deep junction box - 32 mm deep Junction box& with all lead & lifts and as per direction of the Engineer in charge of work. | No | 69.0 | 69.0 | 2.0 | False | None | None | False | None | False | 138.0 | 0 |