1726751561000 | 0 | None | None | Water /sewage treatment tanks | Work of Construction of EFTW Filling point at Nagasandra STP & Yelahanka TTP Coming under of AEE(WMM-STP-H&A.V-2) Sub division | 569598.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4032789 | 156445 | None | One | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of the work - 10.00 HP - 90 LPM @ 220 m = 20 STG Outlet Dia - 2.00" | Each | 54612.0 | 54612.0 | 2.0 | False | None | None | False | None | False | 109224.0 | 0 | 4032790 | 156445 | None | two | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x10 Sqm | Rmtr | 280.0 | 280.0 | 50.0 | False | None | None | False | None | False | 14000.0 | 0 | 4032791 | 156445 | None | Three | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work | Job | 6500.0 | 6500.0 | 2.0 | False | None | None | False | None | False | 13000.0 | 0 | 4032792 | 156445 | None | four | Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work 3.5x25 Sqm | Each | 562.0 | 562.0 | 4.0 | False | None | None | False | None | False | 2248.0 | 0 | 4032793 | 156445 | None | Five | Supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest IS standards | Each | 750.0 | 750.0 | 2.0 | False | None | None | False | None | False | 1500.0 | 0 | 4032794 | 156445 | None | Six | Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.
10 to 12 HP centrifugal pump | Each | 35650.0 | 35650.0 | 2.0 | False | None | None | False | None | False | 71300.0 | 0 | 4032795 | 156445 | None | Seven | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with Each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing for: Note: 1) For small works where the C.M. lining is not practicable for inside surface of the pipe, food grade expoxy painting of two coat over one coat of epoxy primer may be proposed and got approved. 2) The above rates are applicable only for pipe works etc. complete - Pipe bends,branches, tail pieces, reducers etc. for upto 500mm dia pipes (BWSSB SR 2023,24, pageno:71, slno:5.37.1) ID: 100mmdia OD-114.3, 5.4 mm thick pipe for filling point. Weight per mtr: Diameter x 3.14x7.85x thikness in mm x Length | Kg | 170.0 | 170.0 | 1065.52 | False | None | None | False | None | False | 181138.4 | 0 | 4032796 | 156445 | None | Eight | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm | MT | 395.0 | 395.0 | 42.0 | False | None | None | False | None | False | 16590.0 | 0 | 4032797 | 156445 | None | Nine | Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits. 100 mm | Each | 70049.0 | 70049.0 | 2.0 | False | None | None | False | None | False | 140098.0 | 0 | 4032798 | 156445 | None | Ten | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG | Sq CM | 0.5 | 0.5 | 41000.0 | False | None | None | False | None | False | 20500.0 | 0 |
|