3999000 | 154757 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using Dozer In area of light jungle. PWD SR 2021-22 V -3 Item No. 2.5 II A Page No. 09 | Sqm | 412.65 | 412.65 | 8.86 | False | None | None | False | None | False | 3656.079 | 0 |
3999001 | 154757 | None | Code02 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthPWD SR 2021-22 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 1.42 | False | None | None | False | None | False | 141.645 | 0 |
3999002 | 154757 | None | Code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesPWD SR 2021-22 V -1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 45.1553 | False | None | None | False | None | False | 283956.846285 | 0 |
3999003 | 154757 | None | Code04 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2021-22 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 5.2155 | False | None | None | False | None | False | 34626.486825 | 0 |
3999004 | 154757 | None | Code05 | Add 50% for form work Appendix I | Cum | 3319.58 | 3319.58 | 5.2155 | False | None | None | False | None | False | 17313.26949 | 0 |
3999005 | 154757 | None | Code06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.PWD SR 2021-22 V -1 Item No. 1.8 Page No. 07 | Cum | 497.7 | 497.7 | 37.5234 | False | None | None | False | None | False | 18675.39618 | 0 |
3999006 | 154757 | None | Code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 1.764 | False | None | None | False | None | False | 12280.086 | 0 |
3999007 | 154757 | None | Code08 | Add 60% for form work. Appendix I | Cum | 4176.9 | 4176.9 | 1.764 | False | None | None | False | None | False | 7368.0516 | 0 |
3999008 | 154757 | None | Code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 5.5252 | False | None | None | False | None | False | 38463.6798 | 0 |
3999009 | 154757 | None | Code10 | Add 60% for form work. Appendix I | Cum | 4176.9 | 4176.9 | 5.5252 | False | None | None | False | None | False | 23078.20788 | 0 |
3999010 | 154757 | None | Code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 16.0824 | False | None | None | False | None | False | 111957.6276 | 0 |
3999011 | 154757 | None | Code12 | Add 50% for form work. Appendix I | Cum | 3480.75 | 3480.75 | 16.0824 | False | None | None | False | None | False | 55978.8138 | 0 |
3999012 | 154757 | None | Code13 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 529.4 | False | None | None | False | None | False | 133964.67 | 0 |
3999013 | 154757 | None | Code14 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per pecification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.PWD SR 2021-22 V -II Item No. 15.1 Page No. 149 | Sqm | 857.85 | 857.85 | 529.4 | False | None | None | False | None | False | 454145.79 | 0 |
3999014 | 154757 | None | Code15 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.PWD SR 2021-22 V -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.495 | False | None | None | False | None | False | 71763.9615 | 0 |
3999015 | 154757 | None | Code16 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )PWD SR 2021-22 V -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 21.42 | False | None | None | False | None | False | 167423.004 | 0 |
3999016 | 154757 | None | Code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.PWD SR 2021-22 V -II Item No. 11.34 B Page No. 86 | Kg | 192.15 | 192.15 | 595.35 | False | None | None | False | None | False | 114396.5025 | 0 |
3999017 | 154757 | None | Code18 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)PWD SR 2021-22 V -II Item No. 12.90 B Page No. 110 | Sqm | 6692.7 | 6692.7 | 28.35 | False | None | None | False | None | False | 189738.045 | 0 |
3999018 | 154757 | None | Code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 282.81 | False | None | None | False | None | False | 110168.6355 | 0 |
3999019 | 154757 | None | Code20 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 12.672 | False | None | None | False | None | False | 3206.6496 | 0 |
3999020 | 154757 | None | Code21 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.PWD SR 2021-22 V -II Item No. 9.30 Page No. 64 | Sqm | 5594.4 | 5594.4 | 404.3603 | False | None | None | False | None | False | 2262153.26232 | 0 |
3999021 | 154757 | None | Code22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.PWD SR 2021-22 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 1001.3 | False | None | None | False | None | False | 105136.5 | 0 |
3999022 | 154757 | None | Code23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 1001.3 | False | None | None | False | None | False | 133523.355 | 0 |
3999023 | 154757 | None | Code24 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 282.81 | False | None | None | False | None | False | 52857.189 | 0 |
3999024 | 154757 | None | Code25 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin-
charge. PWD SR 2021-22 V -II Item No.8.21 Page No. 44 | Sqm | 27.3 | 27.3 | 282.81 | False | None | None | False | None | False | 7720.713 | 0 |
3999025 | 154757 | None | Code26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2021-22 V -II Item No.8.40 Page No. 48 | Sqm | 120.75 | 120.75 | 28.35 | False | None | None | False | None | False | 3423.2625 | 0 |
3999026 | 154757 | None | Code27 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification . BuildingsPWD SR 2023-24 V -I Item No.2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 2.8058 | False | None | None | False | None | False | 263548.37313 | 0 |
3999027 | 154757 | None | Code28 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)PWD SR 2021-22 V -II Item No.11.26.3 Page No. 84 | Kg | 192.15 | 192.15 | 117.18 | False | None | None | False | None | False | 22516.137 | 0 |
3999028 | 154757 | None | Code29 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick. (Electrical PWD SR 2021-22 PG No.2 ITNO. 1.1.1) | Mtr | 69.0 | 69.0 | 90.0 | False | None | None | False | None | False | 6210.0 | 0 |
3999029 | 154757 | None | Code30 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.(Electrical PWD SR 2021-22 PG No.2 ITNO. 1.1.2) | Mtr | 81.0 | 81.0 | 90.0 | False | None | None | False | None | False | 7290.0 | 0 |
3999030 | 154757 | None | Code31 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.(Electrical PWD SR 2021-22 PG No.2 ITNO. 1.1.3) | Mtr | 106.0 | 106.0 | 90.0 | False | None | None | False | None | False | 9540.0 | 0 |
3999031 | 154757 | None | Code32 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick(Electrical PWD SR 2021-22 PG No.2 ITNO. 1.3.1) | Mtr | 68.0 | 68.0 | 90.0 | False | None | None | False | None | False | 6120.0 | 0 |
3999032 | 154757 | None | Code33 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick (Electrical PWD SR 2021-22 PG No.2 ITNO. 1.3.2) | Mtr | 79.0 | 79.0 | 90.0 | False | None | None | False | None | False | 7110.0 | 0 |
3999033 | 154757 | None | Code34 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick (Electrical PWD SR 2021-22 PG No.2 ITNO. 1.3.3) | Mtr | 99.0 | 99.0 | 90.0 | False | None | None | False | None | False | 8910.0 | 0 |
3999034 | 154757 | None | Code35 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm(Electrical PWD SR 2021-22 PG No.3 ITNO. 1.8.2) | Mtr | 35.0 | 35.0 | 45.0 | False | None | None | False | None | False | 1575.0 | 0 |
3999035 | 154757 | None | Code36 | Supplying And Fixing Metal Fan Box with Round Hook(Electrical PWD SR 2021-22 PG No.4 ITNO. 1.13) | No | 117.0 | 117.0 | 10.0 | False | None | None | False | None | False | 1170.0 | 0 |
3999036 | 154757 | None | Code37 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A 2.2.1 Short point upto 3m from tapping point to out let via switch box(Electrical PWD SR 2021-22 PG No.05 ITNO.2.2.1) | Point | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 |
3999037 | 154757 | None | Code38 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
2.2.2 Medium point above 3m upto 6m from tapping point to out let via switch box(Electrical PWD SR 2021-22 PG No.05 ITNO.2.2.2) | Point | 379.0 | 379.0 | 5.0 | False | None | None | False | None | False | 1895.0 | 0 |
3999038 | 154757 | None | Code39 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box(Electrical PWD SR 2021-22 PG No.05 ITNO.2.2.3) | Point | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 |
3999039 | 154757 | None | Code40 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Electrical PWD SR 2021-22 PG No.05 ITNO.2.2.4) | Point | 677.0 | 677.0 | 5.0 | False | None | None | False | None | False | 3385.0 | 0 |
3999040 | 154757 | None | Code41 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box(Electrical PWD SR 2021-22 PG No.05 ITNO.2.2.5) | Point | 989.0 | 989.0 | 5.0 | False | None | None | False | None | False | 4945.0 | 0 |
3999041 | 154757 | None | Code42 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 (Electrical PWD SR 2021-22 PG No.05 ITNO.2.3.2) | Mtr | 26.0 | 26.0 | 80.0 | False | None | None | False | None | False | 2080.0 | 0 |
3999042 | 154757 | None | Code43 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2(Electrical PWD SR 2021-22 PG No.03 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 80.0 | False | None | None | False | None | False | 3360.0 | 0 |
3999043 | 154757 | None | Code44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2 (Electrical PWD SR 2021-22 PG No.05 ITNO.2.3.4) | Mtr | 63.0 | 63.0 | 80.0 | False | None | None | False | None | False | 5040.0 | 0 |
3999044 | 154757 | None | Code45 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2(Electrical PWD SR 2021-22 PG No.05 ITNO.2.3.5) | Mtr | 92.0 | 92.0 | 80.0 | False | None | None | False | None | False | 7360.0 | 0 |
3999045 | 154757 | None | Code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2(Electrical PWD SR 2021-22 PG No.06 ITNO.2.3.6) | Mtr | 167.0 | 167.0 | 80.0 | False | None | None | False | None | False | 13360.0 | 0 |
3999046 | 154757 | None | Code47 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-2 Way(Electrical PWD SR 2021-22 PG No.08 ITNO.3.4.1) | Each | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
3999047 | 154757 | None | Code48 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way(Electrical PWD SR 2021-22 PG No.08 ITNO.3.4.4) | Each | 220.0 | 220.0 | 5.0 | False | None | None | False | None | False | 1100.0 | 0 |
3999048 | 154757 | None | Code49 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way(Electrical PWD SR 2021-22 PG No.08 ITNO.3.4.5) | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
3999049 | 154757 | None | Code50 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way(Electrical PWD SR 2021-22 PG No.08 ITNO.3.4.6) | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 |
3999050 | 154757 | None | Code51 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module(Electrical PWD SR 2021-22 PG No.08 ITNO.3.5.1) | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 |
3999051 | 154757 | None | Code52 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module(Electrical PWD SR 2021-22 PG No.08 ITNO.3.5.4) | Each | 234.0 | 234.0 | 5.0 | False | None | None | False | None | False | 1170.0 | 0 |
3999052 | 154757 | None | Code53 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module(Electrical PWD SR 2021-22 PG No.08 ITNO.3.5.5) | Each | 284.0 | 284.0 | 5.0 | False | None | None | False | None | False | 1420.0 | 0 |
3999053 | 154757 | None | Code54 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module(Electrical PWD SR 2021-22 PG No.08 ITNO.3.5.6) | Each | 344.0 | 344.0 | 5.0 | False | None | None | False | None | False | 1720.0 | 0 |
3999054 | 154757 | None | Code55 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.1) | Each | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 |
3999055 | 154757 | None | Code56 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.3) | Each | 171.0 | 171.0 | 3.0 | False | None | None | False | None | False | 513.0 | 0 |
3999056 | 154757 | None | Code57 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4 Stepped Fan Regulator Two Module(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.4) | Each | 357.0 | 357.0 | 5.0 | False | None | None | False | None | False | 1785.0 | 0 |
3999057 | 154757 | None | Code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.7) | Each | 180.0 | 180.0 | 5.0 | False | None | None | False | None | False | 900.0 | 0 |
3999058 | 154757 | None | Code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.10) | Each | 236.0 | 236.0 | 5.0 | False | None | None | False | None | False | 1180.0 | 0 |
3999059 | 154757 | None | Code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket(Electrical PWD SR 2021-22 PG No.09 ITNO.3.6.11) | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
3999060 | 154757 | None | Code61 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 4 Way SP & N(Electrical PWD SR 2021-22 PG No.18 ITNO.5.19.6) | Each | 1524.0 | 1524.0 | 3.0 | False | None | None | False | None | False | 4572.0 | 0 |
3999061 | 154757 | None | Code62 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N(Electrical PWD SR 2021-22 PG No.18 ITNO.5.19.7) | Each | 1791.0 | 1791.0 | 3.0 | False | None | None | False | None | False | 5373.0 | 0 |
3999062 | 154757 | None | Code63 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.1 6-32 A SP(Electrical PWD SR 2021-22 PG No.17 ITNO.5.18.1) | Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 |
3999063 | 154757 | None | Code64 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.7 6-32 A TPN(Electrical PWD SR 2021-22 PG No.17 ITNO.5.18.7) | Each | 1717.0 | 1717.0 | 3.0 | False | None | None | False | None | False | 5151.0 | 0 |
3999064 | 154757 | None | Code65 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole(Electrical PWD SR 2021-22 PG No.13 ITNO.5.20.3) | Each | 2826.0 | 2826.0 | 2.0 | False | None | None | False | None | False | 5652.0 | 0 |
3999065 | 154757 | None | Code66 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.4 63 A 4 pole(Electrical PWD SR 2021-22 PG No.13 ITNO.5.20.4) | Each | 3058.0 | 3058.0 | 2.0 | False | None | None | False | None | False | 6116.0 | 0 |
3999066 | 154757 | None | Code67 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A(Electrical PWD SR 2021-22 PG No.21 ITNO.5.45.2) | Each | 971.0 | 971.0 | 1.0 | False | None | None | False | None | False | 971.0 | 0 |
3999067 | 154757 | None | Code68 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A(Electrical PWD SR 2021-22 PG No.21 ITNO.5.45.3) | Each | 1340.0 | 1340.0 | 1.0 | False | None | None | False | None | False | 1340.0 | 0 |
3999068 | 154757 | None | Code69 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)(Electrical Commom SR 2021-22 PG No.13 ITNO.32.11) | Km | 178973.0 | 178973.0 | 0.05 | False | None | None | False | None | False | 8948.65 | 0 |
3999069 | 154757 | None | Code70 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
31.06 35 to 95 Sqmm(Electrical Commom SR 2021-22 PG No.52 ITNO.21.06) | Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 |
3999070 | 154757 | None | Code71 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil(Electrical Commom SR 2021-22 PG No.10 ITNO.1.19.1) | Cum | 454.0 | 454.0 | 9.0 | False | None | None | False | None | False | 4086.0 | 0 |
3999071 | 154757 | None | Code72 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr(Electrical Commom SR 2021-22 PG No.07 ITNO.1.10) | Cum | 160.0 | 160.0 | 9.0 | False | None | None | False | None | False | 1440.0 | 0 |
3999072 | 154757 | None | Code73 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire 6.18.3 8 SWG GI Wire(PWD Electrical SR 2019-20 PG No.44 ITNO.6.18.3) | Mtr | 19.0 | 19.0 | 60.0 | False | None | None | False | None | False | 1140.0 | 0 |
3999073 | 154757 | None | Code74 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x3mm GI strip(PWD Electrical SR 2019-20 PG No.54 ITNO.12.58.1) | Mtr | 82.0 | 82.0 | 35.0 | False | None | None | False | None | False | 2870.0 | 0 |
3999074 | 154757 | None | Code75 | LED Indoor Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4' - 36/40 W(Electrical PWD SR 2021-22 PG No.43 ITNO.11.3.3) | Each | 1269.0 | 1269.0 | 5.0 | False | None | None | False | None | False | 6345.0 | 0 |
3999075 | 154757 | None | Code76 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70%
lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.
11.5.3 LED square or round down light 15-18W(Electrical PWD SR 2021-22 PG No.44 ITNO.11.5.3) | Each | 1324.0 | 1324.0 | 5.0 | False | None | None | False | None | False | 6620.0 | 0 |
3999076 | 154757 | None | Code77 | LED Down light Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited aboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.4. 3 15-18W
(Electrical PWD SR 2021-22 PG No.44 ITNO.11.4.3) | Each | 1671.0 | 1671.0 | 3.0 | False | None | None | False | None | False | 5013.0 | 0 |
3999077 | 154757 | None | Code78 | Supplying and fixing of round or oblong type bulk head fitting glass cover
(Electrical PWD SR 2021-22 PG No.53 ITNO.12.53) | Each | 70.0 | 70.0 | 5.0 | False | None | None | False | None | False | 350.0 | 0 |
3999078 | 154757 | None | Code79 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.
6.3.1 48" Sweep (1200 mm) Regular model
(Electrical PWD SR 2021-22 PG No.30 ITNO.6.3.1) | Each | 2984.0 | 2984.0 | 10.0 | False | None | None | False | None | False | 29840.0 | 0 |
3999079 | 154757 | None | Code80 | Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply.
6.5.2 400 mm Sweep(Electrical PWD SR 2021-22 PG No.30 ITNO.6.5.2) | Each | 3212.0 | 3212.0 | 6.0 | False | None | None | False | None | False | 19272.0 | 0 |
3999080 | 154757 | None | Code81 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 6.2.2 15" Sweep (450 mm)(Electrical PWD SR 2021-22 PG No.30 ITNO.6.2.2) | Each | 4446.0 | 4446.0 | 2.0 | False | None | None | False | None | False | 8892.0 | 0 |
3999081 | 154757 | None | Code82 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required) 13.7.1 On wall/ ceiling / Rafter / Girders(Electrical PWD SR 2021-22 PG No.56 ITNO.13.7.1) | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 |
3999082 | 154757 | None | Code83 | Fixing a ceiling/wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired complete. (Electrical PWD SR 2021-22 PG No.57 ITNO.13.11) | Each | 315.0 | 315.0 | 6.0 | False | None | None | False | None | False | 1890.0 | 0 |
3999083 | 154757 | None | Code84 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. (Electrical PWD SR 2021-22 PG No.57 ITNO.13.13) | Each | 707.0 | 707.0 | 6.0 | False | None | None | False | None | False | 4242.0 | 0 |
3999084 | 154757 | None | Code85 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 PWD SR 2021-22 V -3 Item No.3.6 Page No. 17 | Cum | 517.65 | 517.65 | 77.4 | False | None | None | False | None | False | 40066.11 | 0 |
3999085 | 154757 | None | Code86 | Wet Mix Macadam (Plant mix method) Providing, laying, spreading and mpacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of ixed Material by tipper to site, laying inuniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.PWD SR 2021-22 V -3 Item No. 4.17 Page No. 26 | Cum | 2686.95 | 2686.95 | 14.04 | False | None | None | False | None | False | 37724.778 | 0 |
3999086 | 154757 | None | Code87 | Prime Coat over WMM/WBM (i)Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical ns.PWD SR 2021-22 V -3 Item No. 5.1 A Page No. 31 | Sqm | 43.05 | 43.05 | 93.6 | False | None | None | False | None | False | 4029.48 | 0 |
3999087 | 154757 | None | Code88 | Bituminous Macadam Grading - II for traffic 20 MSA A Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 30 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction PWD SR 2021-22 V -3 Item No. 5.8 (ii)A Page No. 32 | Cum | 8121.75 | 8121.75 | 4.68 | False | None | None | False | None | False | 38009.79 | 0 |
3999088 | 154757 | None | Code89 | Tack coat on Bituminous surface Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broomPWD SR 2021-22 V -3 Item No. 5.3 Page No. 31 | Sqm | 12.6 | 12.6 | 1182.5 | False | None | None | False | None | False | 14899.5 | 0 |
3999089 | 154757 | None | Code90 | Semi Dense Bituminous Concrete Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.PWD SR 2021-22 Vol:3 item no.5.31 page no.43 | Cum | 10659.6 | 10659.6 | 29.5625 | False | None | None | False | None | False | 315124.425 | 0 |
3999090 | 154757 | None | Code91 | Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material by Mechanical Means using Hydraulic excavator with in all lifts and leadPWD SR 2021-22 Vol:3 P.NO.17 Item No:3.5 | Sqm | 6.3 | 6.3 | 2100.0 | False | None | None | False | None | False | 13230.0 | 0 |
3999091 | 154757 | None | Code92 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.PWD SR 2021-22 Vol:3 P.NO.17 I.No:3.7 | Cum | 110.25 | 110.25 | 252.0 | False | None | None | False | None | False | 27783.0 | 0 |
3999092 | 154757 | None | Code93 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other rious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthPWD SR 2021-22 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 189.0 | False | None | None | False | None | False | 18852.75 | 0 |
3999093 | 154757 | None | Code94 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 PWD SR 2021-22 V -3 Item No.3.6 Page No. 17 | Cum | 517.65 | 517.65 | 169.75 | False | None | None | False | None | False | 87871.0875 | 0 |
3999094 | 154757 | None | Code95 | Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying inuniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.PWD SR 2021-22 V -3 Item No. 4.17 Page No. 26 | Cum | 2686.95 | 2686.95 | 250.25 | False | None | None | False | None | False | 672409.2375 | 0 |
3999095 | 154757 | None | Code96 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.PWD SR 2021-22 V -3 Item No. 16.28 Page No. 149 | Cum | 7091.7 | 7091.7 | 346.5 | False | None | None | False | None | False | 2457274.05 | 0 |
3999096 | 154757 | None | Code97 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge.PWD SR 2021-22 V -3 Item No. 17-C(4) Page No. 163 | Mtr | 73.5 | 73.5 | 462.0 | False | None | None | False | None | False | 33957.0 | 0 |