3999102 | 154759 | None | Code01 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In all kinds of soils Depth upto 3 mPWD SR 2023-24 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 16.0 | False | None | None | False | None | False | 1713.6 | 0 |
3999103 | 154759 | None | Code02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.PWD SR 2023-24 V -1 Item No. 1.9 Page No. 07 | Cum | 279.3 | 279.3 | 8.0 | False | None | None | False | None | False | 2234.4 | 0 |
3999104 | 154759 | None | Code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 Vol:1 P.NO.15 I.No:2.1.3 | Cum | 6288.45 | 6288.45 | 0.6 | False | None | None | False | None | False | 3773.07 | 0 |
3999105 | 154759 | None | Code04 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 Vol:1 P.NO.16 I.No: 2.4.2 | Cum | 6639.15 | 6639.15 | 8.54 | False | None | None | False | None | False | 56698.341 | 0 |
3999106 | 154759 | None | Code05 | Add 3% for Form Work, Appendix-I | Cum | 199.17 | 199.17 | 8.54 | False | None | None | False | None | False | 1700.9118 | 0 |
3999107 | 154759 | None | Code06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 Vol:1 P.NO.16 I.No: 2.4.2 | Cum | 6639.15 | 6639.15 | 10.9199 | False | None | None | False | None | False | 72498.854085 | 0 |
3999108 | 154759 | None | Code07 | Add 70% for Form Work, Appendix-I | Cum | 4647.4 | 4647.4 | 10.9199 | False | None | None | False | None | False | 50749.14326 | 0 |
3999109 | 154759 | None | Code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. BuildingsPWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 1.88 | False | None | None | False | None | False | 176588.118 | 0 |
3999110 | 154759 | None | Code09 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.PWD SR 2023-24 Vol:III P.NO.123 I.No:13.14 | Sqm | 88.2 | 88.2 | 36.2159 | False | None | None | False | None | False | 3194.24238 | 0 |
3999111 | 154759 | None | Code10 | Printing new letter and figures of any shade with synthetic enamel paint black or any other pproved colour to give an even shadePWD SR 2023-24 Vol:III P.NO.63 I.No:8.3 | cm | 1.68 | 1.68 | 2250.0 | False | None | None | False | None | False | 3780.0 | 0 |
3999112 | 154759 | None | Code11 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using Dozer B. In area of light junglePWD SR 2023-24 V -III Item No. 2.5 ii A Page No. 07 | 100 Sqm | 412.65 | 412.65 | 1.0 | False | None | None | False | None | False | 412.65 | 0 |
3999113 | 154759 | None | Code12 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.PWD SR 2023-24 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 7.53 | False | None | None | False | None | False | 751.1175 | 0 |
3999114 | 154759 | None | Code13 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In all kinds of soils Depth upto 3 mPWD SR 2023-24 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 105.83 | False | None | None | False | None | False | 11334.393 | 0 |
3999115 | 154759 | None | Code14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 5.7125 | False | None | None | False | None | False | 35922.770625 | 0 |
3999116 | 154759 | None | Code15 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.2.3 Page No. 15 | Cum | 6652.8 | 6652.8 | 23.748 | False | None | None | False | None | False | 157990.6944 | 0 |
3999117 | 154759 | None | Code16 | Add 3% for Form Work, Appendix-I | Cum | 199.58 | 199.58 | 23.748 | False | None | None | False | None | False | 4739.62584 | 0 |
3999118 | 154759 | None | Code17 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per
technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.2 Page No. 16 | Cum | 6804.0 | 6804.0 | 2.5771 | False | None | None | False | None | False | 17534.5884 | 0 |
3999119 | 154759 | None | Code18 | Add 70% for Form Work, Appendix-I | Cum | 4762.8 | 4762.8 | 2.5771 | False | None | None | False | None | False | 12274.21188 | 0 |
3999120 | 154759 | None | Code19 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.2 Page No. 16 | Cum | 6804.0 | 6804.0 | 2.6443 | False | None | None | False | None | False | 17991.8172 | 0 |
3999121 | 154759 | None | Code20 | Add 50% for Form Work, Appendix-I | Cum | 3402.0 | 3402.0 | 2.6443 | False | None | None | False | None | False | 8995.9086 | 0 |
3999122 | 154759 | None | Code21 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.3 Page No. 9 | Cum | 6515.25 | 6515.25 | 11.1293 | False | None | None | False | None | False | 72510.171825 | 0 |
3999123 | 154759 | None | Code22 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.4 Page No. 9 | Cum | 6708.45 | 6708.45 | 7.5404 | False | None | None | False | None | False | 50584.39638 | 0 |
3999124 | 154759 | None | Code23 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.19.1 Page No. 44 | Sqm | 267.75 | 267.75 | 8.235 | False | None | None | False | None | False | 2204.92125 | 0 |
3999125 | 154759 | None | Code24 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.PWD SR 2023-24 V -I Item No. 1.9 Page No. 7 | Cum | 279.3 | 279.3 | 109.7692 | False | None | None | False | None | False | 30658.53756 | 0 |
3999126 | 154759 | None | Code25 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.PWD SR 2023-24 V -II Item No. 6.6 Page No. 13 | Cum | 12205.2 | 12205.2 | 19.5892 | False | None | None | False | None | False | 239090.10384 | 0 |
3999127 | 154759 | None | Code26 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 1.008 | False | None | None | False | None | False | 7017.192 | 0 |
3999128 | 154759 | None | Code27 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 1.008 | False | None | None | False | None | False | 4210.3152 | 0 |
3999129 | 154759 | None | Code28 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 2.3366 | False | None | None | False | None | False | 16266.2409 | 0 |
3999130 | 154759 | None | Code29 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 2.3366 | False | None | None | False | None | False | 9759.74454 | 0 |
3999131 | 154759 | None | Code30 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 3.541 | False | None | None | False | None | False | 24650.6715 | 0 |
3999132 | 154759 | None | Code31 | Add 50% for Form Work, Appendix-I | Cum | 3480.75 | 3480.75 | 3.541 | False | None | None | False | None | False | 12325.33575 | 0 |
3999133 | 154759 | None | Code32 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 28.328 | False | None | None | False | None | False | 7168.4004 | 0 |
3999134 | 154759 | None | Code33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.PWD SR 2023-24 V -II Item No. 11.34 B Page No. 86 | Kg | 192.15 | 192.15 | 34.0199 | False | None | None | False | None | False | 6536.923785 | 0 |
3999135 | 154759 | None | Code34 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 68.878 | False | None | None | False | None | False | 26831.4249 | 0 |
3999136 | 154759 | None | Code35 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 141.0 | False | None | None | False | None | False | 35680.05 | 0 |
3999137 | 154759 | None | Code36 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm PWD SR 2023-24 V -II Item No. 9.17.2 Page No. 61 | Sqm | 1233.75 | 1233.75 | 17.067 | False | None | None | False | None | False | 21056.41125 | 0 |
3999138 | 154759 | None | Code37 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.PWD SR 2023-24 V -II Item No. 10.14 Page No. 71 | Sqm | 1161.3 | 1161.3 | 28.9799 | False | None | None | False | None | False | 33654.35787 | 0 |
3999139 | 154759 | None | Code38 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 112.02 | False | None | None | False | None | False | 14937.867 | 0 |
3999140 | 154759 | None | Code39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 112.02 | False | None | None | False | None | False | 11762.1 | 0 |
3999141 | 154759 | None | Code40 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 68.878 | False | None | None | False | None | False | 12873.2982 | 0 |
3999142 | 154759 | None | Code41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.40 Page No. 48 | Sqm | 120.75 | 120.75 | 1.6199 | False | None | None | False | None | False | 195.602925 | 0 |
3999143 | 154759 | None | Code42 | Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications. PWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 0.922 | False | None | None | False | None | False | 86603.3217 | 0 |
3999144 | 154759 | None | Code43 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargePWD SR 2023-24 V -II Item No-12.54 Page No-104 | Mtr | 333.9 | 333.9 | 12.6 | False | None | None | False | None | False | 4207.14 | 0 |
3999145 | 154759 | None | Code44 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per anufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 -do- with one side prelamPWD SR 2023-24 V -II Item No-12.55.2 Page No-104 | Sqm | 2142.0 | 2142.0 | 12.6 | False | None | None | False | None | False | 26989.2 | 0 |
3999146 | 154759 | None | Code45 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter PWD SR 2023-24 V -II Item No-13.48 Page No -125 | Mtr | 305.55 | 305.55 | 20.0 | False | None | None | False | None | False | 6111.0 | 0 |
3999147 | 154759 | None | Code46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesPWD SR 2023-24 V -II Item No-13.32.2 Page No -122 | Mtr | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 |
3999148 | 154759 | None | Code47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesPWD SR 2023-24 V -II Item No-13.32.4 Page No -122 | Mtr | 584.85 | 584.85 | 20.0 | False | None | None | False | None | False | 11697.0 | 0 |
3999149 | 154759 | None | Code48 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lidPWD SR 2023-24 V -II Item No-14.2.1 Page No-131 | Each | 5079.9 | 5079.9 | 6.0 | False | None | None | False | None | False | 30479.4 | 0 |
3999150 | 154759 | None | Code49 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsPWD SR 2023-24 V -II Item No-14.7.1 Page No-132 | Each | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 |
3999151 | 154759 | None | Code50 | Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal borePWD SR 2023-24 V -II Item No-13.3.2 Page No-117 | Each | 320.25 | 320.25 | 4.0 | False | None | None | False | None | False | 1281.0 | 0 |
3999152 | 154759 | None | Code51 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal borePWD SR 2023-24 V -II Item No-13.5.3 Page No-117 | Each | 348.6 | 348.6 | 4.0 | False | None | None | False | None | False | 1394.4 | 0 |
3999153 | 154759 | None | Code52 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank. PWD SR 2023-24 V -II Item No-13.34 Page No -123 | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
3999154 | 154759 | None | Code53 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length
13.8.2.1 15 mm nominal bore ( item no 13.8.2.1 ) page no 118 PWP. DSR 2023-24 Vol-II | No | 95.55 | 95.55 | 4.0 | False | None | None | False | None | False | 382.2 | 0 |
3999155 | 154759 | None | Code54 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ( item no 14.31 ) page no 136 PWP. DSR 2023-24 Vol-II | No | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 |
3999156 | 154759 | None | Code55 | Providing and fixing 100 mm sand cast Iron grating for gully trap.PWD SR 2023-24 V -II Item No-14.29 Page No-136 | Each | 49.35 | 49.35 | 5.0 | False | None | None | False | None | False | 246.75 | 0 |
3999157 | 154759 | None | Code56 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn -1 DSR 2023-24PWD SR 2023-24 V -I Item No-1.15.1 Page No-08 | Cum | 381.15 | 381.15 | 217.215 | False | None | None | False | None | False | 82791.49725 | 0 |
3999158 | 154759 | None | Code57 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 V -II Item No-6.8 Page No-14 | Cum | 8367.45 | 8367.45 | 1.242 | False | None | None | False | None | False | 10392.3729 | 0 |
3999159 | 154759 | None | Code58 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No-8.9 Page No-42 | Sqm | 404.25 | 404.25 | 18.96 | False | None | None | False | None | False | 7664.58 | 0 |
3999160 | 154759 | None | Code59 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn -2 DSR 2023-24 PWD SR 2023-24 V -II Item No-17.12 Page No-176 | Sqm | 974.4 | 974.4 | 2.0667 | False | None | None | False | None | False | 2013.79248 | 0 |
3999161 | 154759 | None | Code60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023-24 ( item no 14.28.2.1 ) page no 136 PWP. DSR 2023-24 V -II | Each | 96.6 | 96.6 | 3.0 | False | None | None | False | None | False | 289.8 | 0 |
3999162 | 154759 | None | Code61 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : ( item no 14.4.1 ) page no 131 PWP. DSR 2023-24 V -II | Each | 4676.7 | 4676.7 | 2.0 | False | None | None | False | None | False | 9353.4 | 0 |
3999163 | 154759 | None | Code62 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023-24 ( item no 14.28.1.1 ) page no 136 PWP. DSR 2023-24 V -II | Each | 79.8 | 79.8 | 2.0 | False | None | None | False | None | False | 159.6 | 0 |
3999164 | 154759 | None | Code63 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.2) | Mtr | 81.0 | 81.0 | 50.0 | False | None | None | False | None | False | 4050.0 | 0 |
3999165 | 154759 | None | Code64 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.2) | Mtr | 79.0 | 79.0 | 50.0 | False | None | None | False | None | False | 3950.0 | 0 |
3999166 | 154759 | None | Code65 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm(Electrical PWD SR 2023-24 PG No.3 ITNO. 1.8.2) | Mtr | 35.0 | 35.0 | 100.0 | False | None | None | False | None | False | 3500.0 | 0 |
3999167 | 154759 | None | Code66 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.3) | Point | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 |
3999168 | 154759 | None | Code67 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.4) | Point | 677.0 | 677.0 | 5.0 | False | None | None | False | None | False | 3385.0 | 0 |
3999169 | 154759 | None | Code68 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.5) | Point | 989.0 | 989.0 | 1.0 | False | None | None | False | None | False | 989.0 | 0 |
3999170 | 154759 | None | Code69 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2(Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 |
3999171 | 154759 | None | Code70 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 6 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.4) | Each | 220.0 | 220.0 | 1.0 | False | None | None | False | None | False | 220.0 | 0 |
3999172 | 154759 | None | Code71 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4 6 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.4) | Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 |
3999173 | 154759 | None | Code72 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.1) | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
3999174 | 154759 | None | Code73 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.3) | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 |
3999175 | 154759 | None | Code74 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.7 16A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.7) | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3999176 | 154759 | None | Code75 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.10 6/16A Universal Socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.10) | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 |
3999177 | 154759 | None | Code76 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.19.6 4 Way SP & N(Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.6) | Each | 1524.0 | 1524.0 | 1.0 | False | None | None | False | None | False | 1524.0 | 0 |
3999178 | 154759 | None | Code77 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.7 6-32 A TPN(Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.7) | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
3999179 | 154759 | None | Code78 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.5.20.3 32-40 A 4 pole (Electrical PWD SR 2023-24 PG No.13 ITNO.5.20.3) | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
3999180 | 154759 | None | Code79 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A(Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.3) | Each | 1340.0 | 1340.0 | 1.0 | False | None | None | False | None | False | 1340.0 | 0 |
3999181 | 154759 | None | Code80 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)(Electrical Commom SR 2023-24 PG No.13 ITNO.32.11) | Km | 178973.0 | 178973.0 | 0.01 | False | None | None | False | None | False | 1789.73 | 0 |
3999182 | 154759 | None | Code81 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
21.06 35 to 95 Sqmm(Electrical Commom SR 2023-24 PG No.52 ITNO.21.06) | Km | 31139.0 | 31139.0 | 0.01 | False | None | None | False | None | False | 311.39 | 0 |
3999183 | 154759 | None | Code82 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 6.11.6 63mm dia(PWD Electrical SR 2019-20 PG No.42 ITNO.6.11.6) | No | 388.0 | 388.0 | 1.0 | False | None | None | False | None | False | 388.0 | 0 |
3999184 | 154759 | None | Code83 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6.17.3 4 sqmm(PWD Electrical SR 2019-20 PG No.43 ITNO.6.17.3) | No | 7.0 | 7.0 | 20.0 | False | None | None | False | None | False | 140.0 | 0 |
3999185 | 154759 | None | Code84 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6.17.4 6 sqmm(PWD Electrical SR 2019-20 PG No.43 ITNO.6.17.4) | No | 7.0 | 7.0 | 20.0 | False | None | None | False | None | False | 140.0 | 0 |
3999186 | 154759 | None | Code85 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6.17.5 10 sqmm(PWD Electrical SR 2019-20 PG No.43 ITNO.6.17.5) | No | 8.0 | 8.0 | 20.0 | False | None | None | False | None | False | 160.0 | 0 |
3999187 | 154759 | None | Code86 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil(Electrical Commom SR 2023-24 PG No.10 ITNO.1.19.1) | Cum | 484.0 | 484.0 | 3.0 | False | None | None | False | None | False | 1452.0 | 0 |
3999188 | 154759 | None | Code87 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr(Electrical Commom SR 2023-24 PG No.07 ITNO.1.12) | Cum | 160.0 | 160.0 | 3.0 | False | None | None | False | None | False | 480.0 | 0 |
3999189 | 154759 | None | Code88 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts (PWD Electrical SR 2023-24 PG No.54 ITNO.12.57) | No | 4256.0 | 4256.0 | 1.0 | False | None | None | False | None | False | 4256.0 | 0 |
3999190 | 154759 | None | Code89 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x3mm GI strip(PWD Electrical SR 2023-24 PG No.40 ITNO.12.58.2) | Mtr | 82.0 | 82.0 | 20.0 | False | None | None | False | None | False | 1640.0 | 0 |
3999191 | 154759 | None | Code90 | LED Indoor Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4' - 36/40 W(Electrical PWD SR 2023-24 PG No.43 ITNO.11.3.3) | Each | 1269.0 | 1269.0 | 5.0 | False | None | None | False | None | False | 6345.0 | 0 |
3999192 | 154759 | None | Code91 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 6.2.2 15" Sweep (450 mm)(Electrical PWD SR 2023-24 PG No.30 ITNO.6.2.2) | Each | 4446.0 | 4446.0 | 3.0 | False | None | None | False | None | False | 13338.0 | 0 |
3999193 | 154759 | None | Code92 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required) 13.7.1 On wall/ ceiling / Rafter / Girders(Electrical PWD SR 2023-24 PG No.56 ITNO.13.7.1) | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 |
3999194 | 154759 | None | Code93 | Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., Complete. 5.42.1 14 SWG(Electrical PWD SR 2023-24 PG No.20 ITNO.5.42.1)
| Each | 0.5 | 0.5 | 17500.0 | False | None | None | False | None | False | 8750.0 | 0 |
3999195 | 154759 | None | Code94 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 5.40.1 100 A 4 x 30 x 6 mm Aluminium Strips(Electrical PWD SR 2023-24 PG No.20 ITNO.5.40.1) | Mtr | 2465.0 | 2465.0 | 2.0 | False | None | None | False | None | False | 4930.0 | 0 |
3999196 | 154759 | None | Code95 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 5.41.1 40 x 40 x 6 mm(Electrical PWD SR 2023-24 PG No.20 ITNO.5.41.1) | Mtr | 305.0 | 305.0 | 2.0 | False | None | None | False | None | False | 610.0 | 0 |
3999197 | 154759 | None | Code96 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 5.41.4 50 x 100 x 50 x 6 mm C channel(Electrical PWD SR 2023-24 PG No.20 ITNO.5.41.4) | Mtr | 756.0 | 756.0 | 2.0 | False | None | None | False | None | False | 1512.0 | 0 |
3999198 | 154759 | None | Code97 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.(Electrical PWD SR 2023-24 PG No.18 ITNO.5.21) | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3999199 | 154759 | None | Code98 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accurac(Electrical PWD SR 2023-24 PG No.19 ITNO.5.33) | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
3999200 | 154759 | None | Code99 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.(Electrical PWD SR 2023-24 PG No.18 ITNO.5.38) | Each | 515.0 | 515.0 | 1.0 | False | None | None | False | None | False | 515.0 | 0 |
3999201 | 154759 | None | Code100 | Gescom Deposit | LS | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
3999202 | 154759 | None | Code101 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.KUWS & DB Vol-5, 2023-24Pg. No140It. No12.4 | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 |
3999203 | 154759 | None | Code102 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )KUWS & DB Vol-5, 2023-24Pg. No139It. No12.1.1 | Mtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 |
3999204 | 154759 | None | Code103 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )KUWS & DB Vol-5, 2023-24Pg. No139It. No12.1.1 | Mtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 |
3999205 | 154759 | None | Code104 | Providing & fixing 160mm dia 10kg/cm2 ISI Mark Casing PipesKUWS & DB Vol-5, 2023-24Pg. No2It. No58.39 | Mtr | 893.55 | 893.55 | 20.0 | False | None | None | False | None | False | 17871.0 | 0 |
3999206 | 154759 | None | Code105 | Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge KUWS & DB Vol-5, 2023-24Pg. No143It. No12.34 | Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 |
3999207 | 154759 | None | Code106 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.1.50 HP/1.1KW, 12 STG( Crompton or CRI Brands)KUWS & DB Vol-5, 2023-24Pg. No149It. No13.7.3 | Each | 16188.9 | 16188.9 | 1.0 | False | None | None | False | None | False | 16188.9 | 0 |
3999208 | 154759 | None | Code107 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:32mm nominal bore pipesKUWS & DB Vol-5, 2023-24Pg. No191It. No16.7.2 | Mtr | 74.55 | 74.55 | 90.0 | False | None | None | False | None | False | 6709.5 | 0 |
3999209 | 154759 | None | Code108 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.WS & UGD SR 2023-24 IT NO 13.34 Page No-156 | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 |
3999210 | 154759 | None | Code109 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia..WS & UGD SR 2023-24 IT NO 13.39 Page No-157 | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |
3999211 | 154759 | None | Code110 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x2.5 m2KUWS & DB Vol-5, 2023-24Pg. No154It. No13.22.2 | Mtr | 89.25 | 89.25 | 100.0 | False | None | None | False | None | False | 8925.0 | 0 |
3999212 | 154759 | None | Code111 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendmentsSize 50 mmKUWS & DB Vol-5, 2023-24Pg. No154It. No13.24.1 | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
3999213 | 154759 | None | Code112 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendmentsKUWS & DB Vol-5, 2023-24Pg. No154It. No13.25.1 | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
3999214 | 154759 | None | Code113 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter-up to 6HPKUWS & DB Vol-5, 2023-24Pg. No155It. No13.24.2 | Each | 11025.0 | 11025.0 | 1.0 | False | None | None | False | None | False | 11025.0 | 0 |
3999215 | 154759 | None | Code114 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.KUWS & DB Vol-5, 2023-24Pg. No156It. No13.36 | Mtr | 141.75 | 141.75 | 40.0 | False | None | None | False | None | False | 5670.0 | 0 |
3999216 | 154759 | None | Code115 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.PWD SR 2023-24 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 38.25 | False | None | None | False | None | False | 3815.4375 | 0 |
3999217 | 154759 | None | Code116 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In all kinds of soils Depth upto 3 mPWD SR 2023-24 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 87.4999 | False | None | None | False | None | False | 9371.23929 | 0 |
3999218 | 154759 | None | Code117 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 14.8227 | False | None | None | False | None | False | 93211.807815 | 0 |
3999219 | 154759 | None | Code118 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 14.184 | False | None | None | False | None | False | 94169.7036 | 0 |
3999220 | 154759 | None | Code119 | Add 8% for Form Work, Appendix-I | Cum | 531.13 | 531.13 | 14.184 | False | None | None | False | None | False | 7533.54792 | 0 |
3999221 | 154759 | None | Code120 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 6.1851 | False | None | None | False | None | False | 41063.806665 | 0 |
3999222 | 154759 | None | Code121 | Add 70% for Form Work, Appendix-I | Cum | 4647.4 | 4647.4 | 6.1851 | False | None | None | False | None | False | 28744.63374 | 0 |
3999223 | 154759 | None | Code122 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 4.5177 | False | None | None | False | None | False | 29993.687955 | 0 |
3999224 | 154759 | None | Code123 | Add 50% for Form Work, Appendix-I | Cum | 3319.57 | 3319.57 | 4.5177 | False | None | None | False | None | False | 14996.821389 | 0 |
3999225 | 154759 | None | Code124 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.3 Page No. 9 | Cum | 6515.25 | 6515.25 | 18.2087 | False | None | None | False | None | False | 118634.232675 | 0 |
3999226 | 154759 | None | Code125 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.4 Page No. 9 | Cum | 6708.45 | 6708.45 | 16.3697 | False | None | None | False | None | False | 109815.313965 | 0 |
3999227 | 154759 | None | Code126 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.19.1 Page No. 44 | Sqm | 267.75 | 267.75 | 18.228 | False | None | None | False | None | False | 4880.547 | 0 |
3999228 | 154759 | None | Code127 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.PWD SR 2023-24 V -I Item No. 1.9 Page No. 7 | Cum | 279.3 | 279.3 | 155.1494 | False | None | None | False | None | False | 43333.22742 | 0 |
3999229 | 154759 | None | Code128 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.PWD SR 2023-24 V -II Item No. 6.32 Page No. 17 | Sqm | 1375.5 | 1375.5 | 130.746 | False | None | None | False | None | False | 179841.123 | 0 |
3999230 | 154759 | None | Code129 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.09 | False | None | None | False | None | False | 626.535 | 0 |
3999231 | 154759 | None | Code130 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 1.5894 | False | None | None | False | None | False | 11064.6081 | 0 |
3999232 | 154759 | None | Code131 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 1.5894 | False | None | None | False | None | False | 6638.76486 | 0 |
3999233 | 154759 | None | Code132 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.378 | False | None | None | False | None | False | 2631.447 | 0 |
3999234 | 154759 | None | Code133 | Add 45% for Form Work, Appendix-I | Cum | 3132.67 | 3132.67 | 0.378 | False | None | None | False | None | False | 1184.14926 | 0 |
3999235 | 154759 | None | Code134 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 4.5177 | False | None | None | False | None | False | 31449.96855 | 0 |
3999236 | 154759 | None | Code135 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 4.5177 | False | None | None | False | None | False | 18869.98113 | 0 |
3999237 | 154759 | None | Code136 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 17.2265 | False | None | None | False | None | False | 119922.27975 | 0 |
3999238 | 154759 | None | Code137 | Add 50% for Form Work, Appendix-I | Cum | 3480.75 | 3480.75 | 17.226 | False | None | None | False | None | False | 59959.3995 | 0 |
3999239 | 154759 | None | Code138 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 137.8125 | False | None | None | False | None | False | 34873.453125 | 0 |
3999240 | 154759 | None | Code139 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 2.7845 | False | None | None | False | None | False | 19384.29675 | 0 |
3999241 | 154759 | None | Code140 | Add 50% for Form Work, Appendix-I | Cum | 3480.75 | 3480.75 | 2.7845 | False | None | None | False | None | False | 9692.148375 | 0 |
3999242 | 154759 | None | Code141 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.PWD SR 2023-24 V -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.0775 | False | None | None | False | None | False | 11235.77175 | 0 |
3999243 | 154759 | None | Code142 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )PWD SR 2023-24 V -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 4.2 | False | None | None | False | None | False | 32828.04 | 0 |
3999244 | 154759 | None | Code143 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.PWD SR 2023-24 V -II Item No. 11.34 B Page No. 85 | Kg | 192.15 | 192.15 | 170.1 | False | None | None | False | None | False | 32684.715 | 0 |
3999245 | 154759 | None | Code144 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)PWD SR 2023-24 V -II Item No. 12.90 Page No. 110 | Sqm | 7070.7 | 7070.7 | 8.1 | False | None | None | False | None | False | 57272.67 | 0 |
3999246 | 154759 | None | Code145 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 150.872 | False | None | None | False | None | False | 58772.1876 | 0 |
3999247 | 154759 | None | Code146 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 122.86 | False | None | None | False | None | False | 31089.723 | 0 |
3999248 | 154759 | None | Code147 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 12.671 | False | None | None | False | None | False | 3206.39655 | 0 |
3999249 | 154759 | None | Code148 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm PWD SR 2023-24 V -II Item No. 9.17.2 Page No. 60 | Sqm | 1233.75 | 1233.75 | 146.3399 | False | None | None | False | None | False | 180546.851625 | 0 |
3999250 | 154759 | None | Code149 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 260.6725 | False | None | None | False | None | False | 27370.6125 | 0 |
3999251 | 154759 | None | Code150 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 260.6725 | False | None | None | False | None | False | 34760.677875 | 0 |
3999252 | 154759 | None | Code151 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 150.872 | False | None | None | False | None | False | 28197.9768 | 0 |
3999253 | 154759 | None | Code152 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.33.2 Page No. 46 | Sqm | 144.9 | 144.9 | 31.98 | False | None | None | False | None | False | 4633.902 | 0 |
3999254 | 154759 | None | Code153 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 | Sqm | 145.95 | 145.95 | 16.1 | False | None | None | False | None | False | 2349.795 | 0 |
3999255 | 154759 | None | Code154 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. BuildingPWD SR 2023-24 V -I Item No.2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 4.7651 | False | None | None | False | None | False | 447585.128235 | 0 |
3999256 | 154759 | None | Code155 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)PWD SR 2023-24 V -II Item No.11.26.3 Page No. 84 | Kg | 192.15 | 192.15 | 168.0 | False | None | None | False | None | False | 32281.2 | 0 |
3999257 | 154759 | None | Code156 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick. (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.1) | Mtr | 69.0 | 69.0 | 100.0 | False | None | None | False | None | False | 6900.0 | 0 |
3999258 | 154759 | None | Code157 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.2) | Mtr | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 |
3999259 | 154759 | None | Code158 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.3) | Mtr | 106.0 | 106.0 | 30.0 | False | None | None | False | None | False | 3180.0 | 0 |
3999260 | 154759 | None | Code159 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.1) | Mtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 |
3999261 | 154759 | None | Code160 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.2) | Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 |
3999262 | 154759 | None | Code161 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.3) | Mtr | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 |
3999263 | 154759 | None | Code162 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm(Electrical PWD SR 2023-24 PG No.3 ITNO. 1.8.2) | Mtr | 35.0 | 35.0 | 1000.0 | False | None | None | False | None | False | 35000.0 | 0 |
3999264 | 154759 | None | Code163 | Supplying And Fixing Metal Fan Box with Round Hook(Electrical PWD SR 2023-24 PG No.4 ITNO. 1.13) | No | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
3999265 | 154759 | None | Code164 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A 2.2.1 Short point upto 3m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.1) | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
3999266 | 154759 | None | Code165 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
2.2.2 Medium point above 3m upto 6m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.2) | Point | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 |
3999267 | 154759 | None | Code166 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.3) | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 |
3999268 | 154759 | None | Code167 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.4) | Point | 677.0 | 677.0 | 10.0 | False | None | None | False | None | False | 6770.0 | 0 |
3999269 | 154759 | None | Code168 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.5) | Point | 989.0 | 989.0 | 10.0 | False | None | None | False | None | False | 9890.0 | 0 |
3999270 | 154759 | None | Code169 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.2) | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
3999271 | 154759 | None | Code170 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2(Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
3999272 | 154759 | None | Code171 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.4) | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 |
3999273 | 154759 | None | Code172 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2(Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.5) | Mtr | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 |
3999274 | 154759 | None | Code173 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2(Electrical PWD SR 2023-24 PG No.06 ITNO.2.3.6) | Mtr | 167.0 | 167.0 | 100.0 | False | None | None | False | None | False | 16700.0 | 0 |
3999275 | 154759 | None | Code174 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-2Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.1) | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 |
3999276 | 154759 | None | Code175 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 6 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.4) | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
3999277 | 154759 | None | Code176 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 8 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.5) | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
3999278 | 154759 | None | Code177 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6 10-12 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.6) | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 |
3999279 | 154759 | None | Code178 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 2 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.1) | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 |
3999280 | 154759 | None | Code179 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.4) | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
3999281 | 154759 | None | Code180 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.5) | Each | 284.0 | 284.0 | 5.0 | False | None | None | False | None | False | 1420.0 | 0 |
3999282 | 154759 | None | Code181 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.6) | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
3999283 | 154759 | None | Code182 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.1) | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
3999284 | 154759 | None | Code183 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.3) | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 |
3999285 | 154759 | None | Code184 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4 Stepped Fan Regulator Two Module(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.4) | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
3999286 | 154759 | None | Code185 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.7) | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3999287 | 154759 | None | Code186 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.10) | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
3999288 | 154759 | None | Code187 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.11) | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
3999289 | 154759 | None | Code188 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 4 Way SP & N(Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.6) | Each | 1524.0 | 1524.0 | 1.0 | False | None | None | False | None | False | 1524.0 | 0 |
3999290 | 154759 | None | Code189 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N(Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.7) | Each | 1791.0 | 1791.0 | 1.0 | False | None | None | False | None | False | 1791.0 | 0 |
3999291 | 154759 | None | Code190 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP(Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.1) | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
3999292 | 154759 | None | Code191 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN(Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.7) | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
3999293 | 154759 | None | Code192 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole(Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.3) | Each | 2864.0 | 2864.0 | 1.0 | False | None | None | False | None | False | 2864.0 | 0 |
3999294 | 154759 | None | Code193 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.4 63 A 4 pole(Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.4) | Each | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 |
3999295 | 154759 | None | Code194 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A(Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.2) | Each | 971.0 | 971.0 | 1.0 | False | None | None | False | None | False | 971.0 | 0 |
3999296 | 154759 | None | Code195 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A(Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.3) | Each | 1340.0 | 1340.0 | 2.0 | False | None | None | False | None | False | 2680.0 | 0 |
3999297 | 154759 | None | Code196 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)(Electrical Commom SR 2023-24 PG No.13 ITNO.32.11) | Km | 178973.0 | 178973.0 | 0.05 | False | None | None | False | None | False | 8948.65 | 0 |
3999298 | 154759 | None | Code197 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
21.06 35 to 95 Sqmm(Electrical Commom SR 2023-24 PG No.52 ITNO.21.06) | Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 |
3999299 | 154759 | None | Code198 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil(Electrical Commom SR 2023-24 PG No.10 ITNO.1.19.1) | Cum | 454.0 | 454.0 | 30.0 | False | None | None | False | None | False | 13620.0 | 0 |
3999300 | 154759 | None | Code199 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr(Electrical Commom SR 2023-24 PG No.07 ITNO.1.10) | Cum | 160.0 | 160.0 | 30.0 | False | None | None | False | None | False | 4800.0 | 0 |
3999301 | 154759 | None | Code200 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire 6.18.3 8 SWG GI Wire(PWD Electrical SR 2019-20 PG No.44 ITNO.6.18.3) | Mtr | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 |
3999302 | 154759 | None | Code201 | Gescom Deposit | LS | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
3999303 | 154759 | None | Code202 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.PWD SR 2023-24 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 38.25 | False | None | None | False | None | False | 3815.4375 | 0 |
3999304 | 154759 | None | Code203 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In all kinds of soils Depth upto 3 mPWD SR 2023-24 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 87.4999 | False | None | None | False | None | False | 9371.23929 | 0 |
3999305 | 154759 | None | Code204 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 14.8227 | False | None | None | False | None | False | 93211.807815 | 0 |
3999306 | 154759 | None | Code205 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 14.184 | False | None | None | False | None | False | 94169.7036 | 0 |
3999307 | 154759 | None | Code206 | Add 8% for Form Work, Appendix-I | Cum | 531.13 | 531.13 | 14.184 | False | None | None | False | None | False | 7533.54792 | 0 |
3999308 | 154759 | None | Code207 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 6.1851 | False | None | None | False | None | False | 41063.806665 | 0 |
3999309 | 154759 | None | Code208 | Add 70% for Form Work, Appendix-I | Cum | 4647.4 | 4647.4 | 6.1851 | False | None | None | False | None | False | 28744.63374 | 0 |
3999310 | 154759 | None | Code209 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 4.5177 | False | None | None | False | None | False | 29993.687955 | 0 |
3999311 | 154759 | None | Code210 | Add 50% for Form Work, Appendix-I | Cum | 3319.57 | 3319.57 | 4.5177 | False | None | None | False | None | False | 14996.821389 | 0 |
3999312 | 154759 | None | Code211 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.3 Page No. 9 | Cum | 6515.25 | 6515.25 | 18.2087 | False | None | None | False | None | False | 118634.232675 | 0 |
3999313 | 154759 | None | Code212 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)PWD SR 2023-24 V -II Item No. 5.4 Page No. 9 | Cum | 6708.45 | 6708.45 | 16.3697 | False | None | None | False | None | False | 109815.313965 | 0 |
3999314 | 154759 | None | Code213 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.19.1 Page No. 44 | Sqm | 267.75 | 267.75 | 18.2287 | False | None | None | False | None | False | 4880.734425 | 0 |
3999315 | 154759 | None | Code214 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.PWD SR 2023-24 V -I Item No. 1.9 Page No. 7 | Cum | 279.3 | 279.3 | 155.1494 | False | None | None | False | None | False | 43333.22742 | 0 |
3999316 | 154759 | None | Code215 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.PWD SR 2023-24 V -II Item No. 6.32 Page No. 17 | Sqm | 1375.5 | 1375.5 | 130.746 | False | None | None | False | None | False | 179841.123 | 0 |
3999317 | 154759 | None | Code216 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.09 | False | None | None | False | None | False | 626.535 | 0 |
3999318 | 154759 | None | Code217 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 1.5894 | False | None | None | False | None | False | 11064.6081 | 0 |
3999319 | 154759 | None | Code218 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 1.5894 | False | None | None | False | None | False | 6638.76486 | 0 |
3999320 | 154759 | None | Code219 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.378 | False | None | None | False | None | False | 2631.447 | 0 |
3999321 | 154759 | None | Code220 | Add 45% for Form Work, Appendix-I | Cum | 3132.67 | 3132.67 | 0.378 | False | None | None | False | None | False | 1184.14926 | 0 |
3999322 | 154759 | None | Code221 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 4.5177 | False | None | None | False | None | False | 31449.96855 | 0 |
3999323 | 154759 | None | Code222 | Add 60% for Form Work, Appendix-I | Cum | 4176.9 | 4176.9 | 4.5177 | False | None | None | False | None | False | 18869.98113 | 0 |
3999324 | 154759 | None | Code223 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 17.2265 | False | None | None | False | None | False | 119922.27975 | 0 |
3999325 | 154759 | None | Code224 | Add 50% for Form Work, Appendix-I | Cum | 3480.75 | 3480.75 | 17.2265 | False | None | None | False | None | False | 59961.139875 | 0 |
3999326 | 154759 | None | Code225 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 137.8125 | False | None | None | False | None | False | 34873.453125 | 0 |
3999327 | 154759 | None | Code226 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 2.7845 | False | None | None | False | None | False | 19384.29675 | 0 |
3999328 | 154759 | None | Code227 | Add 50% for Form Work, Appendix-I | Cum | 3480.75 | 3480.75 | 2.7845 | False | None | None | False | None | False | 9692.148375 | 0 |
3999329 | 154759 | None | Code228 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.PWD SR 2023-24 V -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.0775 | False | None | None | False | None | False | 11235.77175 | 0 |
3999330 | 154759 | None | Code229 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )PWD SR 2023-24 V -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 4.2 | False | None | None | False | None | False | 32828.04 | 0 |
3999331 | 154759 | None | Code230 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.PWD SR 2023-24 V -II Item No. 11.34 B Page No. 85 | Kg | 192.15 | 192.15 | 170.1 | False | None | None | False | None | False | 32684.715 | 0 |
3999332 | 154759 | None | Code231 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)PWD SR 2023-24 V -II Item No. 12.90 Page No. 110 | Sqm | 7070.7 | 7070.7 | 8.1 | False | None | None | False | None | False | 57272.67 | 0 |
3999333 | 154759 | None | Code232 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 150.872 | False | None | None | False | None | False | 58772.1876 | 0 |
3999334 | 154759 | None | Code233 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 122.86 | False | None | None | False | None | False | 31089.723 | 0 |
3999335 | 154759 | None | Code234 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 12.6719 | False | None | None | False | None | False | 3206.624295 | 0 |
3999336 | 154759 | None | Code235 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm PWD SR 2023-24 V -II Item No. 9.17.2 Page No. 60 | Sqm | 1233.75 | 1233.75 | 146.3399 | False | None | None | False | None | False | 180546.851625 | 0 |
3999337 | 154759 | None | Code236 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 260.6725 | False | None | None | False | None | False | 27370.6125 | 0 |
3999338 | 154759 | None | Code237 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 260.6725 | False | None | None | False | None | False | 34760.677875 | 0 |
3999339 | 154759 | None | Code238 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 150.872 | False | None | None | False | None | False | 28197.9768 | 0 |
3999340 | 154759 | None | Code239 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.33.2 Page No. 46 | Sqm | 144.9 | 144.9 | 31.98 | False | None | None | False | None | False | 4633.902 | 0 |
3999341 | 154759 | None | Code240 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge.PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 | Sqm | 145.95 | 145.95 | 16.1 | False | None | None | False | None | False | 2349.795 | 0 |
3999342 | 154759 | None | Code241 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. BuildingPWD SR 2023-24 V -I Item No.2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 4.7651 | False | None | None | False | None | False | 447585.128235 | 0 |
3999343 | 154759 | None | Code242 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)PWD SR 2023-24 V -II Item No.11.26.3 Page No. 84 | Kg | 192.15 | 192.15 | 168.0 | False | None | None | False | None | False | 32281.2 | 0 |
3999344 | 154759 | None | Code243 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick. (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.1) | Mtr | 69.0 | 69.0 | 100.0 | False | None | None | False | None | False | 6900.0 | 0 |
3999345 | 154759 | None | Code244 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.2) | Mtr | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 |
3999346 | 154759 | None | Code245 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.3) | Mtr | 106.0 | 106.0 | 30.0 | False | None | None | False | None | False | 3180.0 | 0 |
3999347 | 154759 | None | Code246 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick(Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.1) | Mtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 |
3999348 | 154759 | None | Code247 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.2) | Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 |
3999349 | 154759 | None | Code248 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.3) | Mtr | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 |
3999350 | 154759 | None | Code249 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm(Electrical PWD SR 2023-24 PG No.3 ITNO. 1.8.2) | Mtr | 35.0 | 35.0 | 1000.0 | False | None | None | False | None | False | 35000.0 | 0 |
3999351 | 154759 | None | Code250 | Supplying And Fixing Metal Fan Box with Round Hook(Electrical PWD SR 2023-24 PG No.4 ITNO. 1.13) | No | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
3999352 | 154759 | None | Code251 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A 2.2.1 Short point upto 3m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.1) | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
3999353 | 154759 | None | Code252 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
2.2.2 Medium point above 3m upto 6m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.2) | Point | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 |
3999354 | 154759 | None | Code253 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.3) | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 |
3999355 | 154759 | None | Code254 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.4) | Point | 677.0 | 677.0 | 10.0 | False | None | None | False | None | False | 6770.0 | 0 |
3999356 | 154759 | None | Code255 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box(Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.5) | Point | 989.0 | 989.0 | 10.0 | False | None | None | False | None | False | 9890.0 | 0 |
3999357 | 154759 | None | Code256 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.2) | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
3999358 | 154759 | None | Code257 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2(Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
3999359 | 154759 | None | Code258 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.4) | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 |
3999360 | 154759 | None | Code259 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2(Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.5) | Mtr | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 |
3999361 | 154759 | None | Code260 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2(Electrical PWD SR 2023-24 PG No.06 ITNO.2.3.6) | Mtr | 167.0 | 167.0 | 100.0 | False | None | None | False | None | False | 16700.0 | 0 |
3999362 | 154759 | None | Code261 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-2Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.1) | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 |
3999363 | 154759 | None | Code262 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 6 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.4) | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
3999364 | 154759 | None | Code263 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 8 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.5) | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
3999365 | 154759 | None | Code264 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6 10-12 Way(Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.6) | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 |
3999366 | 154759 | None | Code265 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 2 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.1) | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 |
3999367 | 154759 | None | Code266 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.4) | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
3999368 | 154759 | None | Code267 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.5) | Each | 284.0 | 284.0 | 5.0 | False | None | None | False | None | False | 1420.0 | 0 |
3999369 | 154759 | None | Code268 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module(Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.6) | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
3999370 | 154759 | None | Code269 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.1) | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
3999371 | 154759 | None | Code270 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.3) | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 |
3999372 | 154759 | None | Code271 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4 Stepped Fan Regulator Two Module(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.4) | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
3999373 | 154759 | None | Code272 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.7) | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3999374 | 154759 | None | Code273 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.10) | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
3999375 | 154759 | None | Code274 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket(Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.11) | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
3999376 | 154759 | None | Code275 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 4 Way SP & N(Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.6) | Each | 1524.0 | 1524.0 | 1.0 | False | None | None | False | None | False | 1524.0 | 0 |
3999377 | 154759 | None | Code276 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N(Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.7) | Each | 1791.0 | 1791.0 | 1.0 | False | None | None | False | None | False | 1791.0 | 0 |
3999378 | 154759 | None | Code277 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP(Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.1) | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
3999379 | 154759 | None | Code278 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN(Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.7) | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
3999380 | 154759 | None | Code279 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole(Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.3) | Each | 2864.0 | 2864.0 | 1.0 | False | None | None | False | None | False | 2864.0 | 0 |
3999381 | 154759 | None | Code280 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.4 63 A 4 pole(Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.4) | Each | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 |
3999382 | 154759 | None | Code281 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A(Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.2) | Each | 971.0 | 971.0 | 1.0 | False | None | None | False | None | False | 971.0 | 0 |
3999383 | 154759 | None | Code282 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A(Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.3) | Each | 1340.0 | 1340.0 | 2.0 | False | None | None | False | None | False | 2680.0 | 0 |
3999384 | 154759 | None | Code283 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)(Electrical Commom SR 2023-24 PG No.13 ITNO.32.11) | Km | 178973.0 | 178973.0 | 0.05 | False | None | None | False | None | False | 8948.65 | 0 |
3999385 | 154759 | None | Code284 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
21.06 35 to 95 Sqmm(Electrical Commom SR 2023-24 PG No.52 ITNO.21.06) | Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 |
3999386 | 154759 | None | Code285 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil(Electrical Commom SR 2023-24 PG No.10 ITNO.1.19.1) | Cum | 454.0 | 454.0 | 30.0 | False | None | None | False | None | False | 13620.0 | 0 |
3999387 | 154759 | None | Code286 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr(Electrical Commom SR 2023-24 PG No.07 ITNO.1.10) | Cum | 160.0 | 160.0 | 30.0 | False | None | None | False | None | False | 4800.0 | 0 |
3999388 | 154759 | None | Code287 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire 6.18.3 8 SWG GI Wire(PWD Electrical SR 2019-20 PG No.44 ITNO.6.18.3) | Mtr | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 |
3999389 | 154759 | None | Code288 | Gescom Deposit | LS | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
3999390 | 154759 | None | Code289 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shor- ing, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the workVolume No-1, Page No-8, It No-1.12 & DSR-2023-24 | Cum | 99.75 | 99.75 | 9.0 | False | None | None | False | None | False | 897.75 | 0 |
3999391 | 154759 | None | Code290 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mVolume -I, Page No 8, Item No 1.14.1 & DSR 2023-24 | Cum | 107.1 | 107.1 | 46.7415 | False | None | None | False | None | False | 5006.01465 | 0 |
3999392 | 154759 | None | Code291 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates for below footing PCCVolume -I Page No 15 Item No2.1.2 DSR 2023-24 | Cum | 5947.2 | 5947.2 | 3.2566 | False | None | None | False | None | False | 19367.65152 | 0 |
3999393 | 154759 | None | Code292 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.2.1.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesVolume -I, Page No 15, Item No2.2.1 & DSR 2023-24 | Cum | 6601.35 | 6601.35 | 6.075 | False | None | None | False | None | False | 40103.20125 | 0 |
3999394 | 154759 | None | Code293 | Add 5% for Form Work, Appendix-I | Cum | 330.06 | 330.06 | 6.075 | False | None | None | False | None | False | 2005.1145 | 0 |
3999395 | 154759 | None | Code294 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesVolume-1, page No 16, item No 2.5.1 & DSR 2023-24 | Cum | 6961.5 | 6961.5 | 2.3598 | False | None | None | False | None | False | 16427.7477 | 0 |
3999396 | 154759 | None | Code295 | Add 70% for Form Work, Appendix-I | Cum | 348.07 | 348.07 | 2.3598 | False | None | None | False | None | False | 821.375586 | 0 |
3999397 | 154759 | None | Code296 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement 1: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Volume-II, Page No 9, Item No 5.1.1 & DSR-2023-24 | Cum | 5891.55 | 5891.55 | 19.6104 | False | None | None | False | None | False | 115535.65212 | 0 |
3999398 | 154759 | None | Code297 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Volume II, Page no 9, Item no 5.4 & DSR-2023-24 | Cum | 6708.45 | 6708.45 | 13.8706 | False | None | None | False | None | False | 93050.22657 | 0 |
3999399 | 154759 | None | Code298 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesVolume-1, page No 16, Item No 2.5.1 & DSR-2023-24 | Cum | 7657.65 | 7657.65 | 2.1735 | False | None | None | False | None | False | 16643.902275 | 0 |
3999400 | 154759 | None | Code299 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed- ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Volume No-1, Page No-7, It No-1.9 & DSR-2023-24 | Cum | 279.3 | 279.3 | 17.7994 | False | None | None | False | None | False | 4971.37242 | 0 |
3999401 | 154759 | None | Code300 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of our,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Volume No-1, Page No-7, It No-1.8 & DSR-2023-24 | Cum | 497.7 | 497.7 | 28.71 | False | None | None | False | None | False | 14288.967 | 0 |
3999402 | 154759 | None | Code301 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Volume-II, Page No 13, Item No 6.7 & DSR-2023-24 | Cum | 8621.55 | 8621.55 | 9.5188 | False | None | None | False | None | False | 82066.81014 | 0 |
3999403 | 154759 | None | Code302 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesVolume No-1, Page No-16, It No-2.5.1 & DSR-2023-24 | Cum | 6961.5 | 6961.5 | 12.5527 | False | None | None | False | None | False | 87385.62105 | 0 |
3999404 | 154759 | None | Code303 | Add 20% for Form Work, Appendix-I | Cum | 1392.3 | 1392.3 | 12.552 | False | None | None | False | None | False | 17476.1496 | 0 |
3999405 | 154759 | None | Code304 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. BuildingPWD SR 2023-24 V -I Item No.2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 1.7741 | False | None | None | False | None | False | 166640.946885 | 0 |
3999406 | 154759 | None | Code305 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Volume No-2, Page No-41, It No-8.2.1 & DSR-2023-24 | Sqm | 309.75 | 309.75 | 23.58 | False | None | None | False | None | False | 7303.905 | 0 |
3999407 | 154759 | None | Code306 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Volume No-2, Page No-50, It No-8.51 & DSR-2023-24 | Sqm | 105.0 | 105.0 | 60.12 | False | None | None | False | None | False | 6312.6 | 0 |
3999408 | 154759 | None | Code307 | Providing 18mm thick cement plaster in single coat with cement mortar to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. - cement mortar 1:5Volume No-2, Page No-42, It No-8.8 & DSR-2023-24 | Sqm | 389.55 | 389.55 | 60.12 | False | None | None | False | None | False | 23419.746 | 0 |
3999409 | 154759 | None | Code308 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates For Flooring BedVolume No-1, Page No-15, It No-2.1.2 & DSR-2023-24 | Cum | 5947.2 | 5947.2 | 2.7 | False | None | None | False | None | False | 16057.44 | 0 |
3999410 | 154759 | None | Code309 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent.. For FlooringVolume No-2, Page No-63, It No-9.24 & DSR-2023-24 | Sqm | 2994.6 | 2994.6 | 32.4 | False | None | None | False | None | False | 97025.04 | 0 |
3999411 | 154759 | None | Code310 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed including cost of materials, mortar, labour, curing complete as per specifications. For FlooringVolume No-2, Page No-64, It No-9.30 & DSR-2023-24 | Sqm | 5594.4 | 5594.4 | 27.375 | False | None | None | False | None | False | 153146.7 | 0 |
3999412 | 154759 | None | Code311 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Volume No-2, Page No-45, It No-8.25 & DSR-2023-24 | Sqm | 143.85 | 143.85 | 83.7 | False | None | None | False | None | False | 12040.245 | 0 |
3999413 | 154759 | None | Code312 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Volume No-2, Page No-45, It No-8.28 & DSR-2023-24 | Sqm | 93.45 | 93.45 | 103.276 | False | None | None | False | None | False | 9651.1422 | 0 |
3999414 | 154759 | None | Code313 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In all kinds of soils Depth upto 3 m(PWD SR 2023-24 VOL-I PAGE.NO 8 IT.NO 1.14.1 | Cum | 107.1 | 107.1 | 17.901 | False | None | None | False | None | False | 1917.1971 | 0 |
3999415 | 154759 | None | Code314 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 VOL-I PAGE.NO 15 IT.NO 2.1.3) | Cum | 6288.45 | 6288.45 | 0.7897 | False | None | None | False | None | False | 4965.988965 | 0 |
3999416 | 154759 | None | Code315 | Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. (PWD SR 2023-24 VOL-I PAGE.NO 18 IT.NO 2.11.h | Tonne | 82961.55 | 82961.55 | 0.2384 | False | None | None | False | None | False | 19778.03352 | 0 |
3999417 | 154759 | None | Code316 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height.Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 VOL-I PAGE.NO 16 IT.NO 2.4.2) | Cum | 6639.15 | 6639.15 | 7.02 | False | None | None | False | None | False | 46606.833 | 0 |
3999418 | 154759 | None | Code317 | Add 5% for Form Work, Appendix-I | Cum | 331.95 | 331.95 | 7.02 | False | None | None | False | None | False | 2330.289 | 0 |
3999419 | 154759 | None | Code318 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 m - Top 75 mm and Bottom 145 mm dia(Electrical PWD SR 2023-24 PG No.12 ITNO. 4.4.5) | No | 15000.0 | 15000.0 | 13.0 | False | None | None | False | None | False | 195000.0 | 0 |
3999420 | 154759 | None | Code319 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. LED Streetlight 150 Watts (Electrical PWD SR 2023-24 PG No.46 ITNO. 11.8.6) | No | 14705.0 | 14705.0 | 13.0 | False | None | None | False | None | False | 191165.0 | 0 |
3999421 | 154759 | None | Code320 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Single Arm Bracket with 1500 mm Standard 40/50 mm dia(Electrical PWD SR 2023-24 PG No.13 ITNO. 4.6.2) | No | 2100.0 | 2100.0 | 13.0 | False | None | None | False | None | False | 27300.0 | 0 |
3999422 | 154759 | None | Code321 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. (Electrical PWD SR 2023-24 PG No.56 ITNO. 13.5) | No | 162.0 | 162.0 | 13.0 | False | None | None | False | None | False | 2106.0 | 0 |
3999423 | 154759 | None | Code322 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG (Electrical PWD SR 2023-24 PG No.20 ITNO.5.42.1) | Mtr | 0.5 | 0.5 | 36400.0 | False | None | None | False | None | False | 18200.0 | 0 |
3999424 | 154759 | None | Code323 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm(Electrical PWD SR 2023-24 PG No.20 ITNO.5.41.2) | Mtr | 395.0 | 395.0 | 13.0 | False | None | None | False | None | False | 5135.0 | 0 |
3999425 | 154759 | None | Code324 | Supplying, fixing and wiring 0 to 100amps Direct Reading AC analog type Ammeter (Electrical PWD SR 2023-24 PG No.18 ITNO.5.25) | No | 524.0 | 524.0 | 1.0 | False | None | None | False | None | False | 524.0 | 0 |
3999426 | 154759 | None | Code325 | Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter (Electrical PWD SR 2023-24 PG No.18 ITNO.5.24) | No | 465.0 | 465.0 | 1.0 | False | None | None | False | None | False | 465.0 | 0 |
3999427 | 154759 | None | Code326 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C (Electrical PWD SR 2023-24 PG No.19 ITNO.5.38) | No | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
3999428 | 154759 | None | Code327 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP (Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.1) | No | 415.0 | 415.0 | 13.0 | False | None | None | False | None | False | 5395.0 | 0 |
3999429 | 154759 | None | Code328 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN(Electrical PWD SR 2023-24 PG No.18 ITNO.5.18.9) | No | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3999430 | 154759 | None | Code329 | Supply and Installation / Fixing / Provision of Pole boxwith HRC Fuse / MCB provision and suitable connector /terminal for 3 Ph / 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm / 25 Sqmm 3.5 C Al/Ar / Cu/Ar Cable and branch out 2.5 Sqmm 2 core Al/Cu PVCInsulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(WeatherProof), rust proof, dust proof, water proof having InternallyEmbedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/orgrommets.200mmx200mmx98mm (Electrical PWD SR 2023-24 PG No.20 ITNO.5.43.1) | No | 2300.0 | 2300.0 | 13.0 | False | None | None | False | None | False | 29900.0 | 0 |
3999431 | 154759 | None | Code330 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.4 core 16 sqmm (Electrical Commom SR 2023-24 PG No.13 ITNO.32.06) | Km | 141842.0 | 141842.0 | 0.4 | False | None | None | False | None | False | 56736.8 | 0 |
3999432 | 154759 | None | Code331 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.3.5 core 25 sqmm (Electrical Commom SR 2023-24 PG No.13 ITNO.32.06) | Km | 124177.0 | 124177.0 | 0.15 | False | None | None | False | None | False | 18626.55 | 0 |
3999433 | 154759 | None | Code332 | Earthwork excavation for cable trench of 0.5 x 0.75 Mtr. Width and Depth upto 1 Mtr including trial pit, depositing on bank upto lead of 50 Mtr. Supplying of and Dsiplaying of necessary Danger Boardsand Lighting, Using sight rails and Sign Boards at every 100 Mtr Wherever necessary as directed, In ordinary soil (Electrical Commom SR 2023-24 PG No.08 ITNO.1.14.1) | Cum | 102.0 | 102.0 | 0.15 | False | None | None | False | None | False | 15.3 | 0 |
3999434 | 154759 | None | Code333 | Laying of cable in exisying trench/GI pipe/Stone ware/RCC Hume pipe using Wooden/ Aluminium Rollers as directed by departmental staff, 2.5 to 25 Sqmm (Electrical Commom SR 2023-24 PG No.52 ITNO.21.05) | Km | 20886.0 | 20886.0 | 0.4 | False | None | None | False | None | False | 8354.4 | 0 |
3999435 | 154759 | None | Code334 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 ccm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (Electrical Commom SR 2023-24 PG No.07 ITNO.1.10) Basic Rate | Cum | 160.0 | 160.0 | 0.15 | False | None | None | False | None | False | 24.0 | 0 |
3999436 | 154759 | None | Code335 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg (Electrical Commom SR 2023-24 PG No.22 ITNO.51.01) | No | 743.0 | 743.0 | 13.0 | False | None | None | False | None | False | 9659.0 | 0 |
3999437 | 154759 | None | Code336 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm (Electrical PWD SR 2023-24 PG No.03 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 0.4 | False | None | None | False | None | False | 16.8 | 0 |
3999438 | 154759 | None | Code337 | Supply and fixing of 4pole power contactor with NO/NCcontacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.. 65Amps (Electrical PWD SR 2023-24 PG No.16 ITNO.5.14.5) | Each | 10141.0 | 10141.0 | 1.0 | False | None | None | False | None | False | 10141.0 | 0 |
3999439 | 154759 | None | Code338 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. (Electrical PWD SR 2023-24 PG No.21 ITNO.5.48) | No | 4843.0 | 4843.0 | 1.0 | False | None | None | False | None | False | 4843.0 | 0 |
3999440 | 154759 | None | Code339 | Supplying and fixing Moulded Case Circuit Breaker (MCCB)over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have EarthFault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Polesshould have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shallbe provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism.100Amps 25kA. (Electrical PWD SR 2023-24 PG No.17 ITNO.5.15.1) | No | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 |
3999441 | 154759 | None | Code340 | Supplying of multi function digital meter with three line backlight LCD type display for voltage, Current, frequency,Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. 25kA. (Electrical PWD SR 2023-24 PG No.19 ITNO.5.33)Basic Rate | No | 9315.0 | 9315.0 | 2.0 | False | None | None | False | None | False | 18630.0 | 0 |
3999442 | 154759 | None | Code341 | Rod type of earthing using 40mm Dia, 3 mtr Long MS rod as ground rod, in earth pit of 300mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal and connected to equipment ground terminal using PVC Al wire as specified (Electrical Commom SR 2023-24 11 KV System Materials PG No.23 ITNO. 51.04) Part-III | No | 2172.0 | 2172.0 | 13.0 | False | None | None | False | None | False | 28236.0 | 0 |
3999443 | 154759 | None | Code342 | Bentonite clay slurry for earthing in 50 kg Bag (Electrical Commom SR 2023-24 11 KV System Materials PG No.23 ITNO. 51.05) Part-III | Bag | 368.0 | 368.0 | 3.0 | False | None | None | False | None | False | 1104.0 | 0 |
3999444 | 154759 | None | Code343 | GESCOM DEPOSIT | Lump Sum for Each | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
3999445 | 154759 | None | Code344 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In all kinds of soils Depth upto 3 m(PWD SR 2023-24 VOL-I PAGE.NO 8 IT.NO 1.14.1 | Cum | 107.1 | 107.1 | 17.901 | False | None | None | False | None | False | 1917.1971 | 0 |
3999446 | 154759 | None | Code345 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 VOL-I PAGE.NO 15 IT.NO 2.1.3) | Cum | 6288.45 | 6288.45 | 0.7897 | False | None | None | False | None | False | 4965.988965 | 0 |
3999447 | 154759 | None | Code346 | Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. (PWD SR 2023-24 VOL-I PAGE.NO 18 IT.NO 2.11.h | Tonne | 82961.55 | 82961.55 | 0.238 | False | None | None | False | None | False | 19744.8489 | 0 |
3999448 | 154759 | None | Code347 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height.Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 VOL-I PAGE.NO 16 IT.NO 2.4.2) | Cum | 6639.15 | 6639.15 | 7.02 | False | None | None | False | None | False | 46606.833 | 0 |
3999449 | 154759 | None | Code348 | Add 5% for Form Work, Appendix-I | Cum | 331.95 | 331.95 | 7.02 | False | None | None | False | None | False | 2330.289 | 0 |
3999450 | 154759 | None | Code349 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 m - Top 75 mm and Bottom 145 mm dia(Electrical PWD SR 2023-24 PG No.12 ITNO. 4.4.5) | No | 15000.0 | 15000.0 | 13.0 | False | None | None | False | None | False | 195000.0 | 0 |
3999451 | 154759 | None | Code350 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. LED Streetlight 150 Watts (Electrical PWD SR 2023-24 PG No.46 ITNO. 11.8.6) | No | 14705.0 | 14705.0 | 13.0 | False | None | None | False | None | False | 191165.0 | 0 |
3999452 | 154759 | None | Code351 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Single Arm Bracket with 1500 mm Standard 40/50 mm dia(Electrical PWD SR 2023-24 PG No.13 ITNO. 4.6.2) | No | 2100.0 | 2100.0 | 13.0 | False | None | None | False | None | False | 27300.0 | 0 |
3999453 | 154759 | None | Code352 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. (Electrical PWD SR 2023-24 PG No.56 ITNO. 13.5) | Nos. | 162.0 | 162.0 | 13.0 | False | None | None | False | None | False | 2106.0 | 0 |
3999454 | 154759 | None | Code353 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG (Electrical PWD SR 2023-24 PG No.20 ITNO.5.42.1) | Sq CM | 0.5 | 0.5 | 36400.0 | False | None | None | False | None | False | 18200.0 | 0 |
3999455 | 154759 | None | Code354 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm(Electrical PWD SR 2023-24 PG No.20 ITNO.5.41.2) | Mtr | 395.0 | 395.0 | 13.0 | False | None | None | False | None | False | 5135.0 | 0 |
3999456 | 154759 | None | Code355 | Supplying, fixing and wiring 0 to 100amps Direct Reading AC analog type Ammeter (Electrical PWD SR 2023-24 PG No.18 ITNO.5.25) | No | 524.0 | 524.0 | 1.0 | False | None | None | False | None | False | 524.0 | 0 |
3999457 | 154759 | None | Code356 | Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter (Electrical PWD SR 2023-24 PG No.18 ITNO.5.24) | No | 465.0 | 465.0 | 1.0 | False | None | None | False | None | False | 465.0 | 0 |
3999458 | 154759 | None | Code357 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C (Electrical PWD SR 2023-24 PG No.19 ITNO.5.38) | No | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
3999459 | 154759 | None | Code358 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP (Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.1) | No | 415.0 | 415.0 | 13.0 | False | None | None | False | None | False | 5395.0 | 0 |
3999460 | 154759 | None | Code359 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN(Electrical PWD SR 2023-24 PG No.18 ITNO.5.18.9) | No | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3999461 | 154759 | None | Code360 | Supply and Installation / Fixing / Provision of Pole boxwith HRC Fuse / MCB provision and suitable connector /terminal for 3 Ph / 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm / 25 Sqmm 3.5 C Al/Ar / Cu/Ar Cable and branch out 2.5 Sqmm 2 core Al/Cu PVCInsulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(WeatherProof), rust proof, dust proof, water proof having InternallyEmbedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/orgrommets.200mmx200mmx98mm (Electrical PWD SR 2023-24 PG No.20 ITNO.5.43.1) | No | 2300.0 | 2300.0 | 13.0 | False | None | None | False | None | False | 29900.0 | 0 |
3999462 | 154759 | None | Code361 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.4 core 16 sqmm (Electrical Commom SR 2023-24 PG No.13 ITNO.32.06) | Km | 141842.0 | 141842.0 | 0.4 | False | None | None | False | None | False | 56736.8 | 0 |
3999463 | 154759 | None | Code362 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.3.5 core 25 sqmm (Electrical Commom SR 2023-24 PG No.13 ITNO.32.06) | Km | 124177.0 | 124177.0 | 0.15 | False | None | None | False | None | False | 18626.55 | 0 |
3999464 | 154759 | None | Code363 | Earthwork excavation for cable trench of 0.5 x 0.75 Mtr. Width and Depth upto 1 Mtr including trial pit, depositing on bank upto lead of 50 Mtr. Supplying of and Dsiplaying of necessary Danger Boardsand Lighting, Using sight rails and Sign Boards at every 100 Mtr Wherever necessary as directed, In ordinary soil (Electrical Commom SR 2023-24 PG No.08 ITNO.1.14.1) | Cum | 102.0 | 102.0 | 0.15 | False | None | None | False | None | False | 15.3 | 0 |
3999465 | 154759 | None | Code364 | Laying of cable in exisying trench/GI pipe/Stone ware/RCC Hume pipe using Wooden/ Aluminium Rollers as directed by departmental staff, 2.5 to 25 Sqmm (Electrical Commom SR 2023-24 PG No.52 ITNO.21.05) | Km | 20886.0 | 20886.0 | 0.4 | False | None | None | False | None | False | 8354.4 | 0 |
3999466 | 154759 | None | Code365 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 ccm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (Electrical Commom SR 2023-24 PG No.07 ITNO.1.10) Basic Rate | Cum | 160.0 | 160.0 | 0.15 | False | None | None | False | None | False | 24.0 | 0 |
3999467 | 154759 | None | Code366 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg (Electrical Commom SR 2023-24 PG No.22 ITNO.51.01) | No | 743.0 | 743.0 | 13.0 | False | None | None | False | None | False | 9659.0 | 0 |
3999468 | 154759 | None | Code367 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm (Electrical PWD SR 2023-24 PG No.03 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 0.4 | False | None | None | False | None | False | 16.8 | 0 |
3999469 | 154759 | None | Code368 | Supply and fixing of 4pole power contactor with NO/NCcontacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.. 65Amps (Electrical PWD SR 2023-24 PG No.16 ITNO.5.14.5) | Each | 10141.0 | 10141.0 | 1.0 | False | None | None | False | None | False | 10141.0 | 0 |
3999470 | 154759 | None | Code369 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. (Electrical PWD SR 2023-24 PG No.21 ITNO.5.48) | No | 4843.0 | 4843.0 | 1.0 | False | None | None | False | None | False | 4843.0 | 0 |
3999471 | 154759 | None | Code370 | Supplying and fixing Moulded Case Circuit Breaker (MCCB)over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have EarthFault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Polesshould have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shallbe provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism.100Amps 25kA. (Electrical PWD SR 2023-24 PG No.17 ITNO.5.15.1) | No | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 |
3999472 | 154759 | None | Code371 | Supplying of multi function digital meter with three line backlight LCD type display for voltage, Current, frequency,Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. 25kA. (Electrical PWD SR 2023-24 PG No.19 ITNO.5.33)Basic Rate | No | 9315.0 | 9315.0 | 2.0 | False | None | None | False | None | False | 18630.0 | 0 |
3999473 | 154759 | None | Code372 | Rod type of earthing using 40mm Dia, 3 mtr Long MS rod as ground rod, in earth pit of 300mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal and connected to equipment ground terminal using PVC Al wire as specified (Electrical Commom SR 2023-24 11 KV System Materials PG No.23 ITNO. 51.04) Part-III | No | 2172.0 | 2172.0 | 13.0 | False | None | None | False | None | False | 28236.0 | 0 |
3999474 | 154759 | None | Code373 | Bentonite clay slurry for earthing in 50 kg Bag (Electrical Commom SR 2023-24 11 KV System Materials PG No.23 ITNO. 51.05) Part-III | Bag | 368.0 | 368.0 | 3.0 | False | None | None | False | None | False | 1104.0 | 0 |
3999475 | 154759 | None | Code374 | GESCOM DEPOSIT | Lump Sum for Each | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |