3842078 | 146628 | None | MMHB001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workV-1 I.No.1.14.1 P.No.8 | Cum | 107.1 | 107.1 | 861.3 | False | None | None | False | None | False | 92245.23 | 0 |
3842079 | 146628 | None | MMHB002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)V-1 I.No.2.1.3 P.No.15 | Cum | 6288.45 | 6288.45 | 96.52 | False | None | None | False | None | False | 606961.194 | 0 |
3842080 | 146628 | None | MMHB003 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesV-1 I.No.2.2.2 P.No.15 | Cum | 7185.02 | 7185.02 | 111.98 | False | None | None | False | None | False | 804578.5396 | 0 |
3842081 | 146628 | None | MMHB004 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 12214.75 | 12214.75 | 34.06 | False | None | None | False | None | False | 416034.385 | 0 |
3842082 | 146628 | None | MMHB005 | Plinth Beam Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 10777.72 | 10777.72 | 27.92 | False | None | None | False | None | False | 300913.9424 | 0 |
3842083 | 146628 | None | MMHB006 | Chejjas Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 10418.46 | 10418.46 | 1.62 | False | None | None | False | None | False | 16877.9052 | 0 |
3842084 | 146628 | None | MMHB007 | Lintels Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 11496.24 | 11496.24 | 8.84 | False | None | None | False | None | False | 101626.7616 | 0 |
3842085 | 146628 | None | MMHB008 | Roof Beam Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 11496.24 | 11496.24 | 31.63 | False | None | None | False | None | False | 363626.0712 | 0 |
3842086 | 146628 | None | MMHB009 | Roof Slab Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 10777.72 | 10777.72 | 80.57 | False | None | None | False | None | False | 868360.9004 | 0 |
3842087 | 146628 | None | MMHB010 | Staircase Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-1 I.No.2.5.2 P.No.16 | Cum | 10777.72 | 10777.72 | 4.56 | False | None | None | False | None | False | 49146.4032 | 0 |
3842088 | 146628 | None | MMHB011 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sandV-2 I.No.5.2 P.No.9 | Cum | 6948.9 | 6948.9 | 66.62 | False | None | None | False | None | False | 462935.718 | 0 |
3842089 | 146628 | None | MMHB012 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)V-2 I.No.5.4 P.No.9 | Cum | 6708.45 | 6708.45 | 53.29 | False | None | None | False | None | False | 357493.3005 | 0 |
3842090 | 146628 | None | MMHB013 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.V-1 I.No.1.9 P.No.7 | Cum | 279.3 | 279.3 | 1315.17 | False | None | None | False | None | False | 367326.981 | 0 |
3842091 | 146628 | None | MMHB014 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingV-1 I.No.2.11a P.No.18 | Tonne | 93929.85 | 93929.85 | 28.91 | False | None | None | False | None | False | 2715511.9635 | 0 |
3842092 | 146628 | None | MMHB015 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications.V-2 I.No.6.32 P.No.17 | Cum | 1375.5 | 1375.5 | 767.24 | False | None | None | False | None | False | 1055338.62 | 0 |
3842093 | 146628 | None | MMHB016 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.4.1 P.No.41 | Sqm | 339.15 | 339.15 | 480.39 | False | None | None | False | None | False | 162924.2685 | 0 |
3842094 | 146628 | None | MMHB017 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.2.2 P.No.41 | Sqm | 292.95 | 292.95 | 1663.16 | False | None | None | False | None | False | 487222.722 | 0 |
3842095 | 146628 | None | MMHB018 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.8 P.No.42 | Sqm | 389.55 | 389.55 | 431.19 | False | None | None | False | None | False | 167970.0645 | 0 |
3842096 | 146628 | None | MMHB019 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.V-2 I.No.8.25 P.No.50 | Sqm | 105.0 | 105.0 | 1850.64 | False | None | None | False | None | False | 194317.2 | 0 |
3842097 | 146628 | None | MMHB020 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeV-2 I.No.8.25 P.No.45 | Sqm | 143.85 | 143.85 | 2281.84 | False | None | None | False | None | False | 328242.684 | 0 |
3842098 | 146628 | None | MMHB021 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.V-2 I.No.12.12 P.No.99 | Cum | 130412.1 | 130412.1 | 1.18 | False | None | None | False | None | False | 153886.278 | 0 |
3842099 | 146628 | None | MMHB022 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.V-2 I.No.12.51 P.No.104 | Each | 1066.8 | 1066.8 | 18.0 | False | None | None | False | None | False | 19202.4 | 0 |
3842100 | 146628 | None | MMHB023 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)V-2 I.No.12.15 P.No.100 | Sqm | 7241.85 | 7241.85 | 48.23 | False | None | None | False | None | False | 349274.4255 | 0 |
3842101 | 146628 | None | MMHB024 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.V-2 I.No.12.55.1 P.No.104 | Each | 2484.3 | 2484.3 | 18.0 | False | None | None | False | None | False | 44717.4 | 0 |
3842102 | 146628 | None | MMHB025 | Door Fixtures-Providing and fixing bright finished brass handles with screws etc. completeBrass handles 125 mm with plate 175x32 mmV-2 I.No.12.79.1 P.No.108 | Each | 261.45 | 261.45 | 32.0 | False | None | None | False | None | False | 8366.4 | 0 |
3842103 | 146628 | None | MMHB026 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mmV-2 I.No.12.68 P.No.106 | Each | 57.75 | 57.75 | 48.0 | False | None | None | False | None | False | 2772.0 | 0 |
3842104 | 146628 | None | MMHB027 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.V-2 I.No.12.60 P.No.105 | Each | 1104.6 | 1104.6 | 16.0 | False | None | None | False | None | False | 17673.6 | 0 |
3842105 | 146628 | None | MMHB028 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeV-2 I.No.12.63 P.No.105 | Each | 136.5 | 136.5 | 32.0 | False | None | None | False | None | False | 4368.0 | 0 |
3842106 | 146628 | None | MMHB029 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)V-2 I.No.12.84 P.No.108 | Sqm | 5274.15 | 5274.15 | 31.5 | False | None | None | False | None | False | 166135.725 | 0 |
3842107 | 146628 | None | MMHB030 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.V-2 I.No.11.34B P.No.86 | Kg | 192.15 | 192.15 | 402.29 | False | None | None | False | None | False | 77300.0235 | 0 |
3842108 | 146628 | None | MMHB031 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.34.2 P.No.47 | Sqm | 60.9 | 60.9 | 34.81 | False | None | None | False | None | False | 2119.929 | 0 |
3842109 | 146628 | None | MMHB032 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.40 P.No.48 | Sqm | 120.75 | 120.75 | 108.99 | False | None | None | False | None | False | 13160.5425 | 0 |
3842110 | 146628 | None | MMHB033 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mmV-2 I.No.9.12.1 P.No.60 | Sqm | 1136.1 | 1136.1 | 437.98 | False | None | None | False | None | False | 497589.078 | 0 |
3842111 | 146628 | None | MMHB034 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.V-2 I.No.9.11 P.No.60 | Sqm | 933.45 | 933.45 | 18.11 | False | None | None | False | None | False | 16904.7795 | 0 |
3842112 | 146628 | None | MMHB035 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.V-2 I.No.9.39 P.No.65 | Sqm | 1521.45 | 1521.45 | 161.14 | False | None | None | False | None | False | 245166.453 | 0 |
3842113 | 146628 | None | MMHB036 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.V-2 I.No.6.34 P.No.17 | Sqm | 1159.2 | 1159.2 | 81.0 | False | None | None | False | None | False | 93895.2 | 0 |
3842114 | 146628 | None | MMHB037 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.V-2 I.No.11.28 P.No.85 | Kg | 593.25 | 593.25 | 361.6 | False | None | None | False | None | False | 214519.2 | 0 |
3842115 | 146628 | None | MMHB038 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge.G.S. Sheet V-2, I.No19.27.1 P.189 V-2 I.No.19.27.1 P.No.189 | Sqm | 114.45 | 114.45 | 70.49 | False | None | None | False | None | False | 8067.5805 | 0 |
3842116 | 146628 | None | MMHB039 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge. V-2, I.No19.19 P.189V-2 I.No.19.19 P.No.189 | Kgs | 3.15 | 3.15 | 2534.28 | False | None | None | False | None | False | 7982.982 | 0 |
3842117 | 146628 | None | MMHB040 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. V-2, I.No19.3 P.187V-2 I.No.19.3 P.No.187 | Cum | 2547.3 | 2547.3 | 56.18 | False | None | None | False | None | False | 143107.314 | 0 |
3842118 | 146628 | None | MMHB041 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below V-2, I.No19.13.1 P.188V-2 I.No.19.13.1 P.No.188 | Sqm | 98.7 | 98.7 | 22.89 | False | None | None | False | None | False | 2259.243 | 0 |
3842119 | 146628 | None | MMHB042 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge In cement mortar V-2, I.No 19.9.2. P.187V-2 I.No.19.9.2 P.No.187 | Cum | 1768.2 | 1768.2 | 51.36 | False | None | None | False | None | False | 90814.752 | 0 |
3842120 | 146628 | None | MMHB043 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar V-2, I.No 19.7.3 P.187V-2 I.No.19.7.3 P.No.187 | Cum | 1080.45 | 1080.45 | 34.24 | False | None | None | False | None | False | 36994.608 | 0 |
3842121 | 146628 | None | MMHB044 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD Common Sr- 2023-24. Vol-1. Page no: 15,Item No: 2.1.2)V-1 I.No.2.1.2 P.No.15 | Cum | 6125.62 | 6125.62 | 14.05 | False | None | None | False | None | False | 86064.961 | 0 |
3842122 | 146628 | None | MMHB045 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .(PWD Common Sr- 2023-24. Vol-1 .
Page no:15.Item No: 2.2.1)V-1 I.No.2.2.1 P.No.15 | Cum | 6799.39 | 6799.39 | 8.32 | False | None | None | False | None | False | 56570.9248 | 0 |
3842123 | 146628 | None | MMHB046 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..(PWD Common Sr- 2023-24. Vol-1 . Page no:16.Item No: 2.4.3)V-1 I.No.2.4.3 P.No.16 | Cum | 11309.76 | 11309.76 | 1.72 | False | None | None | False | None | False | 19452.7872 | 0 |
3842124 | 146628 | None | MMHB047 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) :(PWD Common Sr- 2023-24. Vol-1 . Page no:9.Item No: 5.1.1)V-1 I.No.5.1.1 P.No.9 | Cum | 5891.55 | 5891.55 | 22.4 | False | None | None | False | None | False | 131970.72 | 0 |
3842125 | 146628 | None | MMHB048 | Refilling available Earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (PWD Common Sr- 2021-22. Vol-1 .
Page no: 7.Item No: 1.10)V-1 I.No.1.10 P.No.7 | Cum | 128.1 | 128.1 | 4.92 | False | None | None | False | None | False | 630.252 | 0 |
3842126 | 146628 | None | MMHB049 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..(PWD Common Sr- 2023-24. Vol-1 . Page no:16.Item No: 2.4.3)V-1 I.No.2.4.3 P.No.16 | Cum | 9979.2 | 9979.2 | 4.97 | False | None | None | False | None | False | 49596.624 | 0 |
3842127 | 146628 | None | MMHB050 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work..(PWD Common Sr- 2023-24. Vol-2 . Page no: 14,Item No: 6.8.)V-2 I.No.6.8 P.No.14 | Cum | 8367.45 | 8367.45 | 29.03 | False | None | None | False | None | False | 242907.0735 | 0 |
3842128 | 146628 | None | MMHB051 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work..(PWD Common Sr- 2023-24. Vol-2 . Page no: 14, Item No:
6.13)V-2 I.No.6.13 P.No.14 | Sqm | 1024.8 | 1024.8 | 28.6 | False | None | None | False | None | False | 29309.28 | 0 |
3842129 | 146628 | None | MMHB052 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(PWD Common Sr- 2023-24.
Vol-2 . Page no: 83, Item No: 11.16.3)V-2 I.No.11.16.3 P.No.83 | Kg | 128.1 | 128.1 | 283.36 | False | None | None | False | None | False | 36298.416 | 0 |
3842130 | 146628 | None | MMHB053 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (PWD Common Sr- 2023-24. Vol-2
. Page no: 26, Item No: 7.38)V-2 I.No.7.38 P.No.26 | Sqm | 596.4 | 596.4 | 34.72 | False | None | None | False | None | False | 20707.008 | 0 |
3842131 | 146628 | None | MMHB054 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :.
Ridges plain (500 - 600mm) (PWD Common Sr- 2023-
24. Vol-2 . Page no: 26, Item No: 7.39.1)V-2 I.No.7.39.1 P.No.26 | Rmtr | 473.55 | 473.55 | 6.2 | False | None | None | False | None | False | 2936.01 | 0 |
3842132 | 146628 | None | MMHB055 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. .Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD Common Sr- 2023-24. Vol-1. Page no: 15,Item No: 2.1.4)V-1 I.No.2.1.4 P.No.15 | Cum | 6527.85 | 6527.85 | 2.51 | False | None | None | False | None | False | 16384.9035 | 0 |
3842133 | 146628 | None | MMHB056 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm
M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in
Charge..(PWD Vol-2 Common Sr- 2023-24 .Page No:77, Item No:11.5.1)V-2 I.No.11.5.1P.No.77 | Sqm | 4701.9 | 4701.9 | 10.08 | False | None | None | False | None | False | 47395.152 | 0 |
3842134 | 146628 | None | MMHB057 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.(PWD Common Sr- 2023-24. Vol-2 .Page no: 86,Item No: 11.34A. )V-2 I.No.11.34A P.No.86 | Kg | 176.4 | 176.4 | 343.29 | False | None | None | False | None | False | 60556.356 | 0 |
3842135 | 146628 | None | MMHB058 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD Common Sr- 2023-24. Vol-2 .Page no: 84,Item No: 11.26.1. )V-2 I.No.11.26.1P.No.84 | Kg | 144.9 | 144.9 | 88.32 | False | None | None | False | None | False | 12797.568 | 0 |
3842136 | 146628 | None | MMHB059 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (PWD Vol-2 Common Sr-2023-2024.Page No:62.Item No:9.21.2)V-2 I.No.9.21.2 P.No.62 | Sqm | 1299.9 | 1299.9 | 36.29 | False | None | None | False | None | False | 47173.371 | 0 |
3842137 | 146628 | None | MMHB060 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includ- ing pointing the joints with white cement and matching pigment etc., complete(PWD Vol-2 Common Sr-2021- 2022.Page No:60.Item No:9.9)V-2 I.No.9.9 P.No.60 | Sqm | 1129.8 | 1129.8 | 15.84 | False | None | None | False | None | False | 17896.032 | 0 |
3842138 | 146628 | None | MMHB061 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(PWD Common Sr- 2023-24. Vol-2 . Page no: 45,Item No: 8.28)V-2 I.No.8.28 P.No.45 | Sqm | 93.45 | 93.45 | 220.12 | False | None | None | False | None | False | 20570.214 | 0 |
3842139 | 146628 | None | MMHB062 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsV-1 I.No.1.10 | Cum | 168.0 | 168.0 | 19.02 | False | None | None | False | None | False | 3195.36 | 0 |
3842140 | 146628 | None | MMHB063 | Providing and fixing in position brass PUSH cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (In Hand Wash) DR | No | 310.8 | 310.8 | 4.0 | False | None | None | False | None | False | 1243.2 | 0 |
3842141 | 146628 | None | MMHB064 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.V-2 I.No.17.12 | Sqm | 974.4 | 974.4 | 3.54 | False | None | None | False | None | False | 3449.376 | 0 |
3842142 | 146628 | None | MMHB065 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(PWD Vol-2 Common Sr- 2023-24 .Page No:100, Item No:12.13.1)V-2 I No.12.13.1 P.No 100 | Cum | 103755.75 | 103755.75 | 0.13 | False | None | None | False | None | False | 13488.2475 | 0 |
3842143 | 146628 | None | MMHB066 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD Vol-2 Common Sr- 2023-24 .Page No:100, Item No:12.21)V-2 I No.12.21 P.No 100 | Cum | 6029.1 | 6029.1 | 5.04 | False | None | None | False | None | False | 30386.664 | 0 |
3842144 | 146628 | None | MMHB067 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL- 16) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD Vol-2 Common Sr-2023-24 .Page No:109, Item No:12.87)V-2 I No.12.87P.No 109 | Sqm | 6878.55 | 6878.55 | 8.63 | False | None | None | False | None | False | 59361.8865 | 0 |
3842145 | 146628 | None | MMHB068 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD Common Sr- 2023-24. Vol-2 .Page no: 41,Item No: 8.3.2.)V-2 I No.8.3.2 P.No 41 | Sqm | 349.65 | 349.65 | 32.52 | False | None | None | False | None | False | 11370.618 | 0 |
3842146 | 146628 | None | MMHB069 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.(PWD Vol-2 Common Sr-2023-2024.Page No:60.Item No:12.12.2) Size of Tile 600x600 mmV-2 I No.9.12.27 P.No 60 | Sqm | 1202.25 | 1202.25 | 39.13 | False | None | None | False | None | False | 47044.0425 | 0 |
3842147 | 146628 | None | MMHB070 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD Common Sr- 2023-24. Vol-2 . Page no: 48, Item No: 8.39) V-2 I No.8.39 P.No 48 | Sqm | 133.35 | 133.35 | 89.47 | False | None | None | False | None | False | 11930.8245 | 0 |
3842148 | 146628 | None | MMHB071 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateV-2 I.No.2.5.2 P.No.16 | Cum | 12336.9 | 12336.9 | 13.23 | False | None | None | False | None | False | 163217.187 | 0 |
3842149 | 146628 | None | MMHB072 | Chejjas Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse V-2 I.No.2.5.2 P.No.16 | Cum | 10522.65 | 10522.65 | 0.4 | False | None | None | False | None | False | 4209.06 | 0 |
3842150 | 146628 | None | MMHB073 | Lintels Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse V-2 I.No.2.5.2 P.No.16 | Cum | 11611.2 | 11611.2 | 3.98 | False | None | None | False | None | False | 46212.576 | 0 |
3842151 | 146628 | None | MMHB074 | Roof Beam Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarsV-2 I.No.2.5.2 P.No.16 | Cum | 11611.2 | 11611.2 | 15.7 | False | None | None | False | None | False | 182295.84 | 0 |
3842152 | 146628 | None | MMHB075 | Roof Slab Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarsV-2 I.No.2.5.2 P.No.16 | Cum | 10885.5 | 10885.5 | 34.44 | False | None | None | False | None | False | 374896.62 | 0 |
3842153 | 146628 | None | MMHB076 | KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500V-1 I.No.2.11a P.No.18 | Tonne | 94869.14 | 94869.14 | 11.14 | False | None | None | False | None | False | 1056842.2196 | 0 |
3842154 | 146628 | None | MMHB077 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.V-2 I.No.6.32 P.No.17 | Cum | 1389.25 | 1389.25 | 349.37 | False | None | None | False | None | False | 485362.2725 | 0 |
3842155 | 146628 | None | MMHB078 | KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.V-2 I.No.8.4.1 P.No.41 | Sqm | 342.54 | 342.54 | 251.14 | False | None | None | False | None | False | 86025.4956 | 0 |
3842156 | 146628 | None | MMHB079 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.2.2 P.No.41 | Sqm | 295.87 | 295.87 | 637.05 | False | None | None | False | None | False | 188483.9835 | 0 |
3842157 | 146628 | None | MMHB080 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.8 P.No.42 | Sqm | 393.44 | 393.44 | 559.68 | False | None | None | False | None | False | 220200.4992 | 0 |
3842158 | 146628 | None | MMHB081 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.V-2 I.No.8.51 P.No.50 | Sqm | 106.05 | 106.05 | 888.2 | False | None | None | False | None | False | 94193.61 | 0 |
3842159 | 146628 | None | MMHB082 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeV-2 I.No.8.25 P.No.45 | Sqm | 145.28 | 145.28 | 1447.88 | False | None | None | False | None | False | 210348.0064 | 0 |
3842160 | 146628 | None | MMHB083 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.V-2 I.No.12.12 P.No.99 | Cum | 131716.22 | 131716.22 | 0.21 | False | None | None | False | None | False | 27660.4062 | 0 |
3842161 | 146628 | None | MMHB084 | KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.V-2 I.No.12.51 P.No.104 | Nos | 1077.46 | 1077.46 | 3.0 | False | None | None | False | None | False | 3232.38 | 0 |
3842162 | 146628 | None | MMHB085 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)V-2 I.No.12.15 P.No.100 | Sqm | 7314.26 | 7314.26 | 8.64 | False | None | None | False | None | False | 63195.2064 | 0 |
3842163 | 146628 | None | MMHB086 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.V-2 I.No.12.55.1 P.No.104 | Sqm | 2509.14 | 2509.14 | 12.59 | False | None | None | False | None | False | 31590.0726 | 0 |
3842164 | 146628 | None | MMHB087 | Door Fixtures-Providing and fixing bright finished brass handles with screws etc. completeBrass handles 125 mm with plate 175x32 mmV-2 I.No.12.79.1 P.No.108 | Nos | 264.06 | 264.06 | 6.0 | False | None | None | False | None | False | 1584.36 | 0 |
3842165 | 146628 | None | MMHB088 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mmV-2 I.No.12.68 P.No.106 | Nos | 58.32 | 58.32 | 9.0 | False | None | None | False | None | False | 524.88 | 0 |
3842166 | 146628 | None | MMHB089 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.V-2 I.No.12.60P.No.105 | Nos | 1115.64 | 1115.64 | 3.0 | False | None | None | False | None | False | 3346.92 | 0 |
3842167 | 146628 | None | MMHB090 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeV-2 I.No.12.63 P.No.105 | Nos | 137.86 | 137.86 | 6.0 | False | None | None | False | None | False | 827.16 | 0 |
3842168 | 146628 | None | MMHB091 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)V-2 I.No.12.84 P.No.108 | Sqm | 5326.89 | 5326.89 | 22.5 | False | None | None | False | None | False | 119855.025 | 0 |
3842169 | 146628 | None | MMHB092 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.V-2 I.No.11.34B P.No.86 | Kgs | 194.07 | 194.07 | 274.86 | False | None | None | False | None | False | 53342.0802 | 0 |
3842170 | 146628 | None | MMHB093 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.34.2 P.No.47 | Sqm | 61.5 | 61.5 | 6.43 | False | None | None | False | None | False | 395.445 | 0 |
3842171 | 146628 | None | MMHB094 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.V-2 I.No.8.40 P.No.48 | Sqm | 121.95 | 121.95 | 29.34 | False | None | None | False | None | False | 3578.013 | 0 |
3842172 | 146628 | None | MMHB095 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mmV-2 I.No.9.12.1 P.No.60 | Sqm | 1147.46 | 1147.46 | 251.14 | False | None | None | False | None | False | 288173.1044 | 0 |
3842173 | 146628 | None | MMHB096 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.V-2 I.No.9.11 P.No.60 | Sqm | 942.78 | 942.78 | 12.64 | False | None | None | False | None | False | 11916.7392 | 0 |
3842174 | 146628 | None | MMHB097 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.V-2 I.No.9.39 P.No.65 | Sqm | 1536.66 | 1536.66 | 74.78 | False | None | None | False | None | False | 114911.4348 | 0 |
3842175 | 146628 | None | MMHB098 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.V-2 I.No.6.34 P.No.17 | Sqm | 1170.79 | 1170.79 | 190.85 | False | None | None | False | None | False | 223445.2715 | 0 |
3842176 | 146628 | None | MMHB099 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.V-2 I.No.11.28 P.No.85 | Kg | 599.18 | 599.18 | 165.96 | False | None | None | False | None | False | 99439.9128 | 0 |
3842177 | 146628 | None | MMHB100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 25 mm nominal dia PipesV-2 I.No.13.33.3 P.No.122 | Mtr | 310.8 | 310.8 | 90.0 | False | None | None | False | None | False | 27972.0 | 0 |
3842178 | 146628 | None | MMHB101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 32 mm nominal dia PipesV-2 I.No.13.33.4 P.No.122 | Mtr | 390.6 | 390.6 | 20.0 | False | None | None | False | None | False | 7812.0 | 0 |
3842179 | 146628 | None | MMHB102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 40 mm nominal dia PipesV-2 I.No.13.33.5 P.No.123 | Mtr | 500.85 | 500.85 | 122.0 | False | None | None | False | None | False | 61103.7 | 0 |
3842180 | 146628 | None | MMHB103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 40 mm nominal dia PipesV-2 I.No.13.33.2 P.No.123 | Mtr | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 |
3842181 | 146628 | None | MMHB104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 20 mm nominal dia PipesV-2 I.No.13.33.2 P.No.122 | Mtr | 227.85 | 227.85 | 60.0 | False | None | None | False | None | False | 13671.0 | 0 |
3842182 | 146628 | None | MMHB105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 25 mm nominal dia PipesV-2 I.No.13.33.3 P.No.122 | Mtr | 310.8 | 310.8 | 50.0 | False | None | None | False | None | False | 15540.0 | 0 |
3842183 | 146628 | None | MMHB106 | Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS : 12701 marked with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tankV-2 I.No.13.34 P.No.123 | Ltr | 9.45 | 9.45 | 5000.0 | False | None | None | False | None | False | 47250.0 | 0 |
3842184 | 146628 | None | MMHB107 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.V-2 I.No.13.15 P.No.119 | Each | 761.25 | 761.25 | 24.0 | False | None | None | False | None | False | 18270.0 | 0 |
3842185 | 146628 | None | MMHB108 | Providing and fixing brass bib cock of approved quality 20 mm nominal boreV-2 I.No.13.2.2 P.No.117 | Each | 320.25 | 320.25 | 24.0 | False | None | None | False | None | False | 7686.0 | 0 |
3842186 | 146628 | None | MMHB109 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal boreV-2 I.No.13.4.3 P.No.117 | Each | 737.1 | 737.1 | 4.0 | False | None | None | False | None | False | 2948.4 | 0 |
3842187 | 146628 | None | MMHB110 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gV-2 I.No.14.40.2 P.No.137 | Each | 520.8 | 520.8 | 18.0 | False | None | None | False | None | False | 9374.4 | 0 |
3842188 | 146628 | None | MMHB111 | Rectangular shape 453x357 mm Mirror with Plastic moulded frameV-2 SI.No.711 P.No.A-33 | Unit | 304.5 | 304.5 | 18.0 | False | None | None | False | None | False | 5481.0 | 0 |
3842189 | 146628 | None | MMHB112 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tapV-2 I.No.14.7.5 P.No.132 | Unit | 2689.05 | 2689.05 | 2.0 | False | None | None | False | None | False | 5378.1 | 0 |
3842190 | 146628 | None | MMHB113 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make andmosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lidV-2 I.No.14.3.1 P.No.131 | Pan | 6275.85 | 6275.85 | 15.0 | False | None | None | False | None | False | 94137.75 | 0 |
3842191 | 146628 | None | MMHB114 | Providing and fixing 100 mm sand cast Iron grating for gully trapV-2 I.No.14.29 P.No.136 | Nos | 49.35 | 49.35 | 20.0 | False | None | None | False | None | False | 987.0 | 0 |
3842192 | 146628 | None | MMHB115 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternV-2 I.No.14.5.1 P.No.132 | Each | 9074.1 | 9074.1 | 8.0 | False | None | None | False | None | False | 72592.8 | 0 |
3842193 | 146628 | None | MMHB116 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.V-2 I.No.10.8 P.No.70 | Sqm | 2928.45 | 2928.45 | 5.4 | False | None | None | False | None | False | 15813.63 | 0 |
3842194 | 146628 | None | MMHB117 | Prvoviding and fixing unplasticied PVC connection pipe with brass union 30cm length 15mm nominal bore | Set | 87.15 | 87.15 | 4.0 | False | None | None | False | None | False | 348.6 | 0 |
3842195 | 146628 | None | MMHB118 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lidV-2 I.No.14.2.2 | Pan | 5076.75 | 5076.75 | 4.0 | False | None | None | False | None | False | 20307.0 | 0 |
3842196 | 146628 | None | MMHB119 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tapV-2 I.No.14.7.7 | Unit | 2203.95 | 2203.95 | 4.0 | False | None | None | False | None | False | 8815.8 | 0 |
3842197 | 146628 | None | MMHB120 | Supplying & erection of RCC rings for well steining of 0.3 Mtr Depth using M-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering, from work and plastering for both faces with C.M 1:3 proportion as per design using 6.50mm M.S. coil at the rate of 10 Kgs/ring including cost of steel and fabrication, bailing out of water, errection etc., complete iii) For 1.20 M dia (clear) rings of steining thickness 0.075 M upto 18 M depth RWS SR 2019-20 Zone-BV-2 I.No.114/11.20.3 | Each | 1097.25 | 1097.25 | 10.0 | False | None | None | False | None | False | 10972.5 | 0 |
3842198 | 146628 | None | MMHB121 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switchEle SR I.No.2.1.1 P.No.05 | Point | 285.0 | 285.0 | 250.0 | False | None | None | False | None | False | 71250.0 | 0 |
3842199 | 146628 | None | MMHB122 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet point wiring using class Medium point above 3 mts upto 6mts from tapping point to outlet via switchEle SR I.No.2.1.2 P.No.05 | Point | 394.0 | 394.0 | 220.0 | False | None | None | False | None | False | 86680.0 | 0 |
3842200 | 146628 | None | MMHB123 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet point wiring using class Long point above 6 mts upto 10 mts from tapping point to outlet via switchEle SR I.No.2.1.3 P.No.05 | Point | 570.0 | 570.0 | 250.0 | False | None | None | False | None | False | 142500.0 | 0 |
3842201 | 146628 | None | MMHB124 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 3 ModuleEle SR I.No.3.4.1 P.No.8 | Each | 138.0 | 138.0 | 63.0 | False | None | None | False | None | False | 8694.0 | 0 |
3842202 | 146628 | None | MMHB125 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5 ModuleEle SR I.No.3.4.3 P.No.8 | Each | 177.0 | 177.0 | 40.0 | False | None | None | False | None | False | 7080.0 | 0 |
3842203 | 146628 | None | MMHB126 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 3 moduleEle SR I.No.3.5.2 P.No.8 | Each | 161.0 | 161.0 | 63.0 | False | None | None | False | None | False | 10143.0 | 0 |
3842204 | 146628 | None | MMHB127 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 moduleEle SR I.No.3.5.3 P.No.8 | Each | 175.0 | 175.0 | 40.0 | False | None | None | False | None | False | 7000.0 | 0 |
3842205 | 146628 | None | MMHB128 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch Ele SR I.No.3.6.1 P.No.9 | Each | 102.0 | 102.0 | 217.0 | False | None | None | False | None | False | 22134.0 | 0 |
3842206 | 146628 | None | MMHB129 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 amps two way switch Ele SR I.No.3.6.2 P.No.9 | Each | 166.0 | 166.0 | 69.0 | False | None | None | False | None | False | 11454.0 | 0 |
3842207 | 146628 | None | MMHB130 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate stepped fan Regulator'sEle SR I.No.3.6.4 P.No.9 | Each | 357.0 | 357.0 | 33.0 | False | None | None | False | None | False | 11781.0 | 0 |
3842208 | 146628 | None | MMHB131 | Supply and fixing one metal Fan box with round hook Ele SR I.No.1.13 P.No.4 | Each | 117.0 | 117.0 | 31.0 | False | None | None | False | None | False | 3627.0 | 0 |
3842209 | 146628 | None | MMHB132 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete.Ele SR I.No.5.45.1 P.No.21 | Each | 945.0 | 945.0 | 22.0 | False | None | None | False | None | False | 20790.0 | 0 |
3842210 | 146628 | None | MMHB133 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 20 mm diaEle SR I.No.1.2.1 P.No.2 | Mtr | 66.0 | 66.0 | 250.0 | False | None | None | False | None | False | 16500.0 | 0 |
3842211 | 146628 | None | MMHB134 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 25 mm diaEle SR I.No.1.2.2 P.No.2 | Mtr | 78.0 | 78.0 | 250.0 | False | None | None | False | None | False | 19500.0 | 0 |
3842212 | 146628 | None | MMHB135 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 40 mm dia 2.5mm thickEle SR I.No.1.2.4 P.No.2 | Mtr | 147.0 | 147.0 | 220.0 | False | None | None | False | None | False | 32340.0 | 0 |
3842213 | 146628 | None | MMHB136 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mmEle SR I.No.2.3.2 P.No.5 | Mtr | 26.0 | 26.0 | 180.0 | False | None | None | False | None | False | 4680.0 | 0 |
3842214 | 146628 | None | MMHB137 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mmEle SR I.No.2.3.3 P.No.5 | Mtr | 42.0 | 42.0 | 150.0 | False | None | None | False | None | False | 6300.0 | 0 |
3842215 | 146628 | None | MMHB138 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mmEle SR I.No.2.3.4 P.No.5 | Mtr | 63.0 | 63.0 | 180.0 | False | None | None | False | None | False | 11340.0 | 0 |
3842216 | 146628 | None | MMHB139 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.6sq.mmEle SR I.No.2.3.5 P.No.5 | Mtr | 92.0 | 92.0 | 200.0 | False | None | None | False | None | False | 18400.0 | 0 |
3842217 | 146628 | None | MMHB140 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.10sq.mmEle SR I.No.2.3.6 P.No.5 | Mtr | 167.0 | 167.0 | 110.0 | False | None | None | False | None | False | 18370.0 | 0 |
3842218 | 146628 | None | MMHB141 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.6 Way TP & N( LDB/PDB)Ele SR I.No.5.19.12 P.No.18 | Each | 4940.0 | 4940.0 | 10.0 | False | None | None | False | None | False | 49400.0 | 0 |
3842219 | 146628 | None | MMHB142 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 5-32 Amps SPEle SR I.No.5.18.1 P.No.17 | Each | 415.0 | 415.0 | 38.0 | False | None | None | False | None | False | 15770.0 | 0 |
3842220 | 146628 | None | MMHB143 | Supplying and fixing 63A DP MCB miniature circuit breaker on the existing MCB distribution board ( Main / EMGPNL)using necessary fixing materials and wiring complete as requiredEle SR I.No.5.18.6 P.No.17 | Each | 1102.0 | 1102.0 | 22.0 | False | None | None | False | None | False | 24244.0 | 0 |
3842221 | 146628 | None | MMHB144 | Supplying and fixing 32A DP MCB miniature circuit breaker on the existing MCB distribution board (EMG PNL) using necessary fixing materials and wiring complete as requiredEle SR I.No.5.18.4 P.No.17 | Each | 739.0 | 739.0 | 15.0 | False | None | None | False | None | False | 11085.0 | 0 |
3842222 | 146628 | None | MMHB145 | Supply of box type suitable for 28W T5 single/twin lamp and suspension mounted luminaire & optical reflector. Prewired with HF electronic ballast, push fit type lamp holders and main contactors. Channel cover shall be made of CRCA MS sheet & finishing is done with stove enameled white with end caps made of engineering plastic.1x 4'-28WEle SR I.No.11.3.3 P.No.43 | Each | 1269.0 | 1269.0 | 60.0 | False | None | None | False | None | False | 76140.0 | 0 |
3842223 | 146628 | None | MMHB146 | Supplying capacitor type 48" sweep ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system [Khaitan, Crompton greaves, Usha]Ele SR I.No.6.3.1 P.No.30 | Each | 2984.0 | 2984.0 | 33.0 | False | None | None | False | None | False | 98472.0 | 0 |
3842224 | 146628 | None | MMHB147 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-chargeEle SR I.No.13.10 P.No.57 | Each | 171.0 | 171.0 | 31.0 | False | None | None | False | None | False | 5301.0 | 0 |
3842225 | 146628 | None | MMHB148 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thickEle SR I.No.1.2.1 | Mtr | 69.3 | 69.3 | 145.0 | False | None | None | False | None | False | 10048.5 | 0 |
3842226 | 146628 | None | MMHB149 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 125mm dia 2mm thickEle SR I.No.1.2.2 | Mtr | 81.9 | 81.9 | 50.0 | False | None | None | False | None | False | 4095.0 | 0 |
3842227 | 146628 | None | MMHB150 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75x75x65mmEle SR I.No.1.4.1 | Each | 106.0 | 106.0 | 9.0 | False | None | None | False | None | False | 954.0 | 0 |
3842228 | 146628 | None | MMHB151 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 100x75x65mmEle SR I.No.1.4.2 | Each | 118.0 | 118.0 | 6.0 | False | None | None | False | None | False | 708.0 | 0 |
3842229 | 146628 | None | MMHB152 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc180X90X65mmEle SR I.No.1.4.4 | Each | 161.0 | 161.0 | 6.0 | False | None | None | False | None | False | 966.0 | 0 |
3842230 | 146628 | None | MMHB153 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction BoxEle SR I.No.1.5.1 | Each | 49.0 | 49.0 | 9.0 | False | None | None | False | None | False | 441.0 | 0 |
3842231 | 146628 | None | MMHB154 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction BoxEle SR I.No.1.5.2 | Each | 56.0 | 56.0 | 3.0 | False | None | None | False | None | False | 168.0 | 0 |
3842232 | 146628 | None | MMHB155 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm Conduit in Brick WallsEle SR I.No.1.7.1 | Mtr | 29.0 | 29.0 | 27.0 | False | None | None | False | None | False | 783.0 | 0 |
3842233 | 146628 | None | MMHB156 | Supplying And Fixing Metal Fan Box with Round Hook. Ele SR I.No.1.13 | Nos | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
3842234 | 146628 | None | MMHB157 | Point wiring Copper without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing usingf 1100v Grade , COPPER conductor flexible multistrand FRLS PVC insulated., 2x1.5 Sqm. Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. Complete for each outlet(5/2.3) Group A Short piont up to 3 Mtr from tapping piont out let via switch. Ele SR I.No.1.2.1 | Point | 269.0 | 269.0 | 11.0 | False | None | None | False | None | False | 2959.0 | 0 |
3842235 | 146628 | None | MMHB158 | Point wiring Copper without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing usingf 1100v Grade , COPPER conductor flexible multistrand FRLS PVC insulated., 2x1.5 Sqm. Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. Complete for each outlet(5/2.3) Group A Short piont up to 6 Mtr from tapping piont out Ele SR I.No.1.2.2 | Point | 379.0 | 379.0 | 6.0 | False | None | None | False | None | False | 2274.0 | 0 |
3842236 | 146628 | None | MMHB159 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 SqmmEle SR I.No.2.3.2 | Mtr | 26.0 | 26.0 | 240.0 | False | None | None | False | None | False | 6240.0 | 0 |
3842237 | 146628 | None | MMHB160 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 SqmmEle SR I.No.2.3.3 | Mtr | 42.0 | 42.0 | 78.0 | False | None | None | False | None | False | 3276.0 | 0 |
3842238 | 146628 | None | MMHB161 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.4 ModuleEle SR I.No.3.5.2 | Each | 161.0 | 161.0 | 6.0 | False | None | None | False | None | False | 966.0 | 0 |
3842239 | 146628 | None | MMHB162 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box1 to 3 ModuleEle SR I.No.3.5.1 | Each | 137.0 | 137.0 | 1.0 | False | None | None | False | None | False | 137.0 | 0 |
3842240 | 146628 | None | MMHB163 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.8 ModuleEle SR I.No.3.5.5 | Each | 284.0 | 284.0 | 6.0 | False | None | None | False | None | False | 1704.0 | 0 |
3842241 | 146628 | None | MMHB164 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEle SR I.No.3.6.7 | Each | 180.0 | 180.0 | 3.0 | False | None | None | False | None | False | 540.0 | 0 |
3842242 | 146628 | None | MMHB165 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEle SR I.No.3.6.10 | Each | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 |
3842243 | 146628 | None | MMHB166 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & completely wired on existing box.Ele SR I.No.3.7 | Each | 646.0 | 646.0 | 3.0 | False | None | None | False | None | False | 1938.0 | 0 |
3842244 | 146628 | None | MMHB167 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32AmpsEle SR I.No.5.7.2 | Each | 241.0 | 241.0 | 9.0 | False | None | None | False | None | False | 2169.0 | 0 |
3842245 | 146628 | None | MMHB168 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & NEle SR I.No.5.19.8 | Each | 1854.0 | 1854.0 | 3.0 | False | None | None | False | None | False | 5562.0 | 0 |
3842246 | 146628 | None | MMHB169 | Earth Electrode for Grounding Supplying fixing andwiring earth electrode for groundingof lifts, transformers, DGsetsetc. using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nutsEle SR I.No.12.57 | Job | 4256.0 | 4256.0 | 3.0 | False | None | None | False | None | False | 12768.0 | 0 |
3842247 | 146628 | None | MMHB170 | PVC Batten with LED Tubes Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor less then 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w Ele SR I.No.11.3.2 | Each | 690.0 | 690.0 | 12.0 | False | None | None | False | None | False | 8280.0 | 0 |
3842248 | 146628 | None | MMHB171 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Ele SR I.No.13.7.1 | Each | 122.0 | 122.0 | 13.0 | False | None | None | False | None | False | 1586.0 | 0 |
3842249 | 146628 | None | MMHB172 | Supplying 250 amps rated 3phase Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium StripsEle SR I.No.5.40.2 | m | 3435.0 | 3435.0 | 0.5 | False | None | None | False | None | False | 1717.5 | 0 |
3842250 | 146628 | None | MMHB173 | Energy Meter. Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. Ele SR I.No.5.35 | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 |
3842251 | 146628 | None | MMHB174 | Fluorescent Tubes Supplying and fixing of 5'-80 Watts of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating. Operating voltage range from 180V to 265V, 50Hz AC power Supply Ele SR I.No.12.21 | Nos | 520.0 | 520.0 | 1.0 | False | None | None | False | None | False | 520.0 | 0 |
3842252 | 146628 | None | MMHB175 | Patty Type Fittimg Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting. Ele SR I.No.12.25.2 | Each | 340.0 | 340.0 | 1.0 | False | None | None | False | None | False | 340.0 | 0 |
3842253 | 146628 | None | MMHB176 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Ele SR I.No.12.46 | Nos | 63.0 | 63.0 | 3.0 | False | None | None | False | None | False | 189.0 | 0 |
3842254 | 146628 | None | MMHB177 | Fixing of Fan Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. Ele SR I.No.13.11 | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 |