tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1726813043000 | 0 | None | None | Buildings | Ground Floor | 3050796.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035239 | 156539 | None | PWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) B | Ground Floor: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | 100 Sqm | 1575.0 | 1575.0 | 2.12 | False | None | None | False | None | False | 3339.0 | 0 | 4035240 | 156539 | None | PWD V- 2 SR 2023-24 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 99.75 | 99.75 | 42.38 | False | None | None | False | None | False | 4227.405 | 0 | 4035241 | 156539 | None | PWD V- 1 SR 2023-24 Page No-5 It No-1.4.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 254.1 | 254.1 | 133.61 | False | None | None | False | None | False | 33950.301 | 0 | 4035242 | 156539 | None | PWD V- 1 SR 2023-24 Page No-6 It No-1.5.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 313.95 | 313.95 | 33.4 | False | None | None | False | None | False | 10485.93 | 0 | 4035243 | 156539 | None | PWD V- 2 SR 2023-24 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @
3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 123.9 | 123.9 | 104.26 | False | None | None | False | None | False | 12917.814 | 0 | 4035244 | 156539 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 279.3 | 279.3 | 133.61 | False | None | None | False | None | False | 37317.273 | 0 | 4035245 | 156539 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 497.7 | 497.7 | 62.58 | False | None | None | False | None | False | 31146.066 | 0 | 4035246 | 156539 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5947.2 | 5947.2 | 22.16 | False | None | None | False | None | False | 131789.952 | 0 | 4035247 | 156539 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7129.46 | 7129.46 | 30.77 | False | None | None | False | None | False | 219373.4842 | 0 | 4035248 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to Plinth ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11286.55 | 11286.55 | 2.03 | False | None | None | False | None | False | 22911.6965 | 0 | 4035249 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAM ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 9958.73 | 9958.73 | 11.73 | False | None | None | False | None | False | 116815.9029 | 0 | 4035250 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11834.55 | 11834.55 | 4.78 | False | None | None | False | None | False | 56569.149 | 0 | 4035251 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11138.4 | 11138.4 | 5.19 | False | None | None | False | None | False | 57808.296 | 0 | 4035252 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLAB ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10442.25 | 10442.25 | 15.8 | False | None | None | False | None | False | 164987.55 | 0 | 4035253 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASE ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10442.25 | 10442.25 | 2.95 | False | None | None | False | None | False | 30804.6375 | 0 | 4035254 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11138.4 | 11138.4 | 2.65 | False | None | None | False | None | False | 29516.76 | 0 | 4035255 | 156539 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Chejja ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10094.18 | 10094.18 | 0.61 | False | None | None | False | None | False | 6157.4498 | 0 | 4035256 | 156539 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10444.56 | 10444.56 | 3.58 | False | None | None | False | None | False | 37391.5248 | 0 | 4035257 | 156539 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | t | 93929.85 | 93929.85 | 6.92 | False | None | None | False | None | False | 649994.562 | 0 | 4035258 | 156539 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8367.45 | 8367.45 | 49.27 | False | None | None | False | None | False | 412264.2615 | 0 | 4035259 | 156539 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1113.0 | 1113.0 | 37.58 | False | None | None | False | None | False | 41826.54 | 0 | 4035260 | 156539 | None | PWD V- 2 SR 2023-24 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 103755.75 | 103755.75 | 0.4 | False | None | None | False | None | False | 41502.3 | 0 | 4035261 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.57.2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercial ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3667.65 | 3667.65 | 11.34 | False | None | None | False | None | False | 41591.151 | 0 | 4035262 | 156539 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 737.1 | 737.1 | 24.0 | False | None | None | False | None | False | 17690.4 | 0 | 4035263 | 156539 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3659.25 | 3659.25 | 6.3 | False | None | None | False | None | False | 23053.275 | 0 | 4035264 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1066.8 | 1066.8 | 6.0 | False | None | None | False | None | False | 6400.8 | 0 | 4035265 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1104.6 | 1104.6 | 6.0 | False | None | None | False | None | False | 6627.6 | 0 | 4035266 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1039.5 | 1039.5 | 6.0 | False | None | None | False | None | False | 6237.0 | 0 | 4035267 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 248.85 | 248.85 | 12.0 | False | None | None | False | None | False | 2986.2 | 0 | 4035268 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 136.5 | 136.5 | 12.0 | False | None | None | False | None | False | 1638.0 | 0 | 4035269 | 156539 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 57.75 | 57.75 | 12.0 | False | None | None | False | None | False | 693.0 | 0 | 4035270 | 156539 | None | PWD V- 2 SR 2023-24 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 288.75 | 288.75 | 12.0 | False | None | None | False | None | False | 3465.0 | 0 | 4035271 | 156539 | None | PWD V- 2 SR 2023-24 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 63.0 | 63.0 | 36.0 | False | None | None | False | None | False | 2268.0 | 0 | 4035272 | 156539 | None | PWD V- 2 SR 2023-24 Page No-205 It No-20.80 | Supplying and fixing new Honne wood beads wherever necessary
including cost of materials, labour, complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 44.1 | 44.1 | 35.4 | False | None | None | False | None | False | 1561.14 | 0 | 4035273 | 156539 | None | PWD V- 2 SR 2023-24 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Kg | 176.4 | 176.4 | 232.47 | False | None | None | False | None | False | 41007.708 | 0 | 4035274 | 156539 | None | PWD V- 2 SR 2023-24 Page No-110 It No-12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 6878.55 | 6878.55 | 10.35 | False | None | None | False | None | False | 71192.9925 | 0 | 4035275 | 156539 | None | PWD V- 2 SR 2023-24 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 6004.95 | 6004.95 | 0.72 | False | None | None | False | None | False | 4323.564 | 0 | 4035276 | 156539 | None | PWD V- 2 SR 2023-24 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 221.55 | 221.55 | 92.87 | False | None | None | False | None | False | 20575.3485 | 0 | 4035277 | 156539 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 267.75 | 267.75 | 330.84 | False | None | None | False | None | False | 88582.41 | 0 | 4035278 | 156539 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 327.6 | 327.6 | 38.43 | False | None | None | False | None | False | 12589.668 | 0 | 4035279 | 156539 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 292.95 | 292.95 | 225.61 | False | None | None | False | None | False | 66092.4495 | 0 | 4035280 | 156539 | None | PWD V- 2 SR 2023-24 Page No-43 It No-8.16.3 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm wide ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 46.2 | 46.2 | 408.6 | False | None | None | False | None | False | 18877.32 | 0 | 4035281 | 156539 | None | PWD V- 2 SR 2023-24 Page No-54 It No-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 54.6 | 54.6 | 238.64 | False | None | None | False | None | False | 13029.744 | 0 | 4035282 | 156539 | None | PWD V- 2 SR 2021-22 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1202.25 | 1202.25 | 72.88 | False | None | None | False | None | False | 87619.98 | 0 | 4035283 | 156539 | None | PWD V- 2 SR 2023-24 Page No-63 It No-9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 2994.6 | 2994.6 | 31.52 | False | None | None | False | None | False | 94389.792 | 0 | 4035284 | 156539 | None | PWD V- 2 SR 2023-24 Page No-60 It No-9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1129.8 | 1129.8 | 7.2 | False | None | None | False | None | False | 8134.56 | 0 | 4035285 | 156539 | None | PWD V- 2 SR 2023-24 Page No-9.39 It No-65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1521.45 | 1521.45 | 38.43 | False | None | None | False | None | False | 58469.3235 | 0 | 4035286 | 156539 | None | PWD V- 2 SR 2021-22 Page No-83 It No-11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Kgs | 593.25 | 593.25 | 94.5 | False | None | None | False | None | False | 56062.125 | 0 | 4035287 | 156539 | None | PWD V- 2 SR 2023-24 Page No-50 It No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 105.0 | 105.0 | 423.71 | False | None | None | False | None | False | 44489.55 | 0 | 4035288 | 156539 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 133.35 | 133.35 | 423.71 | False | None | None | False | None | False | 56501.7285 | 0 | 4035289 | 156539 | None | PWD V- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 163.8 | 163.8 | 225.61 | False | None | None | False | None | False | 36954.918 | 0 | 4035290 | 156539 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 53.0 | 53.0 | 11.07 | False | None | None | False | None | False | 586.71 | 0 | 4035291 | 156539 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 121.9 | 121.9 | 11.07 | False | None | None | False | None | False | 1349.433 | 0 | 4035292 | 156539 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 55.65 | 55.65 | 27.22 | False | None | None | False | None | False | 1514.793 | 0 | 4035293 | 156539 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.38 | Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 42.0 | 42.0 | 27.22 | False | None | None | False | None | False | 1143.24 | 0 |
| 1726813043000 | 0 | None | None | Buildings | First Floor | 1750143.03 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035294 | 156540 | None | PWD V- 1 SR 2023-24 Page No-17 It No-2.5.1 | First Floor: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11900.85 | 11900.85 | 5.06 | False | None | None | False | None | False | 60218.301 | 0 | 4035295 | 156540 | None | PWD V- 1 SR 2023-24 Page No-17 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11204.7 | 11204.7 | 5.0 | False | None | None | False | None | False | 56023.5 | 0 | 4035296 | 156540 | None | PWD V- 1 SR 2023-24 Page No-17 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLAB ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10508.55 | 10508.55 | 13.56 | False | None | None | False | None | False | 142495.938 | 0 | 4035297 | 156540 | None | PWD V- 1 SR 2023-24 Page No-17 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELS ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11204.7 | 11204.7 | 1.91 | False | None | None | False | None | False | 21400.977 | 0 | 4035298 | 156540 | None | PWD V- 1 SR 2023-24 Page No-17 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Chejja ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 10160.47 | 10160.47 | 0.63 | False | None | None | False | None | False | 6401.0961 | 0 | 4035299 | 156540 | None | PWD V- 2 SR 2023-24 Page No-15 It No-2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7833.42 | 7833.42 | 9.87 | False | None | None | False | None | False | 77315.8554 | 0 | 4035300 | 156540 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | t | 94824.42 | 94824.42 | 2.84 | False | None | None | False | None | False | 269301.3528 | 0 | 4035301 | 156540 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8447.14 | 8447.14 | 35.58 | False | None | None | False | None | False | 300549.2412 | 0 | 4035302 | 156540 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1123.6 | 1123.6 | 41.21 | False | None | None | False | None | False | 46303.556 | 0 | 4035303 | 156540 | None | PWD V- 2 SR 2023-24 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 104743.9 | 104743.9 | 0.33 | False | None | None | False | None | False | 34565.487 | 0 | 4035304 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.57.2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercial ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3702.58 | 3702.58 | 9.42 | False | None | None | False | None | False | 34878.3036 | 0 | 4035305 | 156540 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 744.12 | 744.12 | 12.0 | False | None | None | False | None | False | 8929.44 | 0 | 4035306 | 156540 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3694.1 | 3694.1 | 3.15 | False | None | None | False | None | False | 11636.415 | 0 | 4035307 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1076.96 | 1076.96 | 5.0 | False | None | None | False | None | False | 5384.8 | 0 | 4035308 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1115.12 | 1115.12 | 5.0 | False | None | None | False | None | False | 5575.6 | 0 | 4035309 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1049.4 | 1049.4 | 7.0 | False | None | None | False | None | False | 7345.8 | 0 | 4035310 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 251.22 | 251.22 | 12.0 | False | None | None | False | None | False | 3014.64 | 0 | 4035311 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 137.8 | 137.8 | 12.0 | False | None | None | False | None | False | 1653.6 | 0 | 4035312 | 156540 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 58.3 | 58.3 | 10.0 | False | None | None | False | None | False | 583.0 | 0 | 4035313 | 156540 | None | PWD V- 2 SR 2023-24 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 291.5 | 291.5 | 14.0 | False | None | None | False | None | False | 4081.0 | 0 | 4035314 | 156540 | None | PWD V- 2 SR 2023-24 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 63.6 | 63.6 | 34.0 | False | None | None | False | None | False | 2162.4 | 0 | 4035315 | 156540 | None | PWD V- 2 SR 2023-24 Page No-205 It No-20.80 | Supplying and fixing new Honne wood beads wherever necessary
including cost of materials, labour, complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 44.52 | 44.52 | 23.0 | False | None | None | False | None | False | 1023.96 | 0 | 4035316 | 156540 | None | PWD V- 2 SR 2023-24 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Kg | 178.08 | 178.08 | 163.62 | False | None | None | False | None | False | 29137.4496 | 0 | 4035317 | 156540 | None | PWD V- 2 SR 2023-24 Page No-110 It No-12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 6944.06 | 6944.06 | 8.37 | False | None | None | False | None | False | 58121.7822 | 0 | 4035318 | 156540 | None | PWD V- 2 SR 2023-24 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 6062.14 | 6062.14 | 0.72 | False | None | None | False | None | False | 4364.7408 | 0 | 4035319 | 156540 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.1.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 223.66 | 223.66 | 87.99 | False | None | None | False | None | False | 19679.8434 | 0 | 4035320 | 156540 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 270.3 | 270.3 | 297.92 | False | None | None | False | None | False | 80527.776 | 0 | 4035321 | 156540 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 330.72 | 330.72 | 32.02 | False | None | None | False | None | False | 10589.6544 | 0 | 4035322 | 156540 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 295.74 | 295.74 | 233.86 | False | None | None | False | None | False | 69161.7564 | 0 | 4035323 | 156540 | None | PWD V- 2 SR 2023-24 Page No-43 It No-8.16.3 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm wide ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 46.64 | 46.64 | 268.8 | False | None | None | False | None | False | 12536.832 | 0 | 4035324 | 156540 | None | PWD V- 2 SR 2023-24 Page No-54 It No-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 55.12 | 55.12 | 171.55 | False | None | None | False | None | False | 9455.836 | 0 | 4035325 | 156540 | None | PWD V- 2 SR 2021-22 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1213.7 | 1213.7 | 55.67 | False | None | None | False | None | False | 67566.679 | 0 | 4035326 | 156540 | None | PWD V- 2 SR 2023-24 Page No-60 It No-9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1140.56 | 1140.56 | 5.98 | False | None | None | False | None | False | 6820.5488 | 0 | 4035327 | 156540 | None | PWD V- 2 SR 2023-24 Page No-9.39 It No-65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1535.94 | 1535.94 | 32.02 | False | None | None | False | None | False | 49180.7988 | 0 | 4035328 | 156540 | None | PWD V- 2 SR 2023-24 Page No-63 It No-9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3023.12 | 3023.12 | 2.56 | False | None | None | False | None | False | 7739.1872 | 0 | 4035329 | 156540 | None | PWD V- 2 SR 2021-22 Page No-50 It No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 106.0 | 106.0 | 385.91 | False | None | None | False | None | False | 40906.46 | 0 | 4035330 | 156540 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 134.62 | 134.62 | 385.91 | False | None | None | False | None | False | 51951.2042 | 0 | 4035331 | 156540 | None | PWD V- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 165.36 | 165.36 | 233.86 | False | None | None | False | None | False | 38671.0896 | 0 | 4035332 | 156540 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 53.0 | 53.0 | 9.09 | False | None | None | False | None | False | 481.77 | 0 | 4035333 | 156540 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 121.9 | 121.9 | 9.09 | False | None | None | False | None | False | 1108.071 | 0 | 4035334 | 156540 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 56.18 | 56.18 | 22.6 | False | None | None | False | None | False | 1269.668 | 0 | 4035335 | 156540 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.38 | Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 42.4 | 42.4 | 22.6 | False | None | None | False | None | False | 958.24 | 0 | 4035336 | 156540 | None | PWD V- 2 SR 2023-24 Page No-133 It No-15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 789.7 | 789.7 | 109.54 | False | None | None | False | None | False | 86503.738 | 0 | 4035337 | 156540 | None | PWD V- 2 SR 2021-22 Page No-23 It No-7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 2138.02 | 2138.02 | 1.2 | False | None | None | False | None | False | 2565.624 | 0 |
| 1726813043000 | 0 | None | None | Buildings | Water Supply and Sanitation | 177001.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035338 | 156541 | None | PWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2 | Water Supply and Sanitation: Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 92.4 | 92.4 | 20.0 | False | None | None | False | None | False | 1848.0 | 0 | 4035339 | 156541 | None | PWD V- 2 SR 2023-24 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 303.45 | 303.45 | 50.0 | False | None | None | False | None | False | 15172.5 | 0 | 4035340 | 156541 | None | PWD V- 2 SR 2023-24 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 404.25 | 404.25 | 40.0 | False | None | None | False | None | False | 16170.0 | 0 | 4035341 | 156541 | None | PWD V- 2 SR 2023-24 Page No-125 It No-13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 206.85 | 206.85 | 40.0 | False | None | None | False | None | False | 8274.0 | 0 | 4035342 | 156541 | None | PWD V- 2 SR 2023-24 Page No-124 It No-13.44 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all
fitting arrangements & all necessary accessories complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 231.0 | 231.0 | 10.0 | False | None | None | False | None | False | 2310.0 | 0 | 4035343 | 156541 | None | PWD V- 2 SR 2023-24 Page No-124 It No-13.44 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all
fitting arrangements & all necessary accessories complete ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 363.3 | 363.3 | 6.0 | False | None | None | False | None | False | 2179.8 | 0 | 4035344 | 156541 | None | PWD V- 2 SR 2023-24 Page No-136 It No-14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1281.0 | 1281.0 | 4.0 | False | None | None | False | None | False | 5124.0 | 0 | 4035345 | 156541 | None | PWD V- 2 SR 2023-24 Page No-123 It No-14.3.2 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm
flush bend, overflow arrangement with specials of standard make and
mosquito proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making good
the walls and floors wherever required :
W.C. pan with ISI marked black solid plastic seat and lid ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 6095.25 | 6095.25 | 1.0 | False | None | None | False | None | False | 6095.25 | 0 | 4035346 | 156541 | None | MARKET RATE | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 2100.0 | 2100.0 | 1.0 | False | None | None | False | None | False | 2100.0 | 0 | 4035347 | 156541 | None | PWD V- 2 SR 2023-24 Page No-131 It No-14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 5128.2 | 5128.2 | 3.0 | False | None | None | False | None | False | 15384.6 | 0 | 4035348 | 156541 | None | PWD V- 2 SR 2023-24 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 4676.7 | 4676.7 | 1.0 | False | None | None | False | None | False | 4676.7 | 0 | 4035349 | 156541 | None | PWD V- 2 SR 2023-24 Page No-124 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and making good the walls
wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 2689.05 | 2689.05 | 5.0 | False | None | None | False | None | False | 13445.25 | 0 | 4035350 | 156541 | None | PWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board 610x510 mm bowl depth 200 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 5662.65 | 5662.65 | 1.0 | False | None | None | False | None | False | 5662.65 | 0 | 4035351 | 156541 | None | PWD V- 2 SR 2021-22 Page No-136 It No-14.27.2 | Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings :
Size 600x450x200 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 3489.15 | 3489.15 | 1.0 | False | None | None | False | None | False | 3489.15 | 0 | 4035352 | 156541 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal dia Pipes ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 324.45 | 324.45 | 25.0 | False | None | None | False | None | False | 8111.25 | 0 | 4035353 | 156541 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25 mm nominal dia Pipes ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 310.8 | 310.8 | 20.0 | False | None | None | False | None | False | 6216.0 | 0 | 4035354 | 156541 | None | PWD V- 2 SR 2023-24 Page No-115 It No-13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 25 mm nominal bore ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 576.45 | 576.45 | 6.0 | False | None | None | False | None | False | 3458.7 | 0 | 4035355 | 156541 | None | PWD V- 2 SR 2023-24 Page No-139 It No-14.55.a | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1172.85 | 1172.85 | 4.0 | False | None | None | False | None | False | 4691.4 | 0 | 4035356 | 156541 | None | PWD V- 5 SR 2023-24 Page No-191 It No-16.10 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for
fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 4447.8 | 4447.8 | 5.0 | False | None | None | False | None | False | 22239.0 | 0 | 4035357 | 156541 | None | PWD V- 5 SR 2023-24 Page No-191 It No-16.9 | Constructing brick masonry chamber of internal dimension 600x600mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for
fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 5726.7 | 5726.7 | 2.0 | False | None | None | False | None | False | 11453.4 | 0 | 4035358 | 156541 | None | PWD V- 2 SR 2023-24 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
| 1726813043000 | 0 | None | None | Buildings | Electrification | 310235.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035359 | 156542 | None | PWD SR V-6 Item No-2.1.1 | Electrification: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Point | 299.25 | 299.25 | 30.0 | False | None | None | False | None | False | 8977.5 | 0 | 4035360 | 156542 | None | PWD SR V-6 Item No-2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Point | 413.7 | 413.7 | 22.0 | False | None | None | False | None | False | 9101.4 | 0 | 4035361 | 156542 | None | PWD SR V-6 Item No-2.1.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Point | 598.5 | 598.5 | 16.0 | False | None | None | False | None | False | 9576.0 | 0 | 4035362 | 156542 | None | PWD SR V-6 Item No-3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2Way ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 144.9 | 144.9 | 21.0 | False | None | None | False | None | False | 3042.9 | 0 | 4035363 | 156542 | None | PWD SR V-6 Item No-3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5Way ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 4035364 | 156542 | None | PWD SR V-6 Item No-3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6Way ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 231.0 | 231.0 | 2.0 | False | None | None | False | None | False | 462.0 | 0 | 4035365 | 156542 | None | PWD SR V-6 Item No-3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 Way ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 274.05 | 274.05 | 13.0 | False | None | None | False | None | False | 3562.65 | 0 | 4035366 | 156542 | None | PWD SR V-6 Item No-3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12Way ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 334.95 | 334.95 | 4.0 | False | None | None | False | None | False | 1339.8 | 0 | 4035367 | 156542 | None | PWD SR V-6 Item No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 143.85 | 143.85 | 21.0 | False | None | None | False | None | False | 3020.85 | 0 | 4035368 | 156542 | None | PWD SR V-6 Item No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 183.75 | 183.75 | 6.0 | False | None | None | False | None | False | 1102.5 | 0 | 4035369 | 156542 | None | PWD SR V-6 Item No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 245.7 | 245.7 | 2.0 | False | None | None | False | None | False | 491.4 | 0 | 4035370 | 156542 | None | PWD SR V-6 Item No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 298.2 | 298.2 | 13.0 | False | None | None | False | None | False | 3876.6 | 0 | 4035371 | 156542 | None | PWD SR V-6 Item No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 361.2 | 361.2 | 4.0 | False | None | None | False | None | False | 1444.8 | 0 | 4035372 | 156542 | None | PWD SR V-6 Item No-3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 107.1 | 107.1 | 102.0 | False | None | None | False | None | False | 10924.2 | 0 | 4035373 | 156542 | None | PWD SR V-6 Item No-3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 179.55 | 179.55 | 37.0 | False | None | None | False | None | False | 6643.35 | 0 | 4035374 | 156542 | None | PWD SR V-6 Item No-3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 374.85 | 374.85 | 12.0 | False | None | None | False | None | False | 4498.2 | 0 | 4035375 | 156542 | None | PWD SR V-6 Item No-3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 189.0 | 189.0 | 11.0 | False | None | None | False | None | False | 2079.0 | 0 | 4035376 | 156542 | None | PWD SR V-6 Item No-3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 342.3 | 342.3 | 6.0 | False | None | None | False | None | False | 2053.8 | 0 | 4035377 | 156542 | None | PWD SR V-6 Item No-3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 247.8 | 247.8 | 17.0 | False | None | None | False | None | False | 4212.6 | 0 | 4035378 | 156542 | None | PWD SR V-6 Item No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 258.3 | 258.3 | 2.0 | False | None | None | False | None | False | 516.6 | 0 | 4035379 | 156542 | None | PWD SR V-6 Item No-1.13 | Supplying And Fixing Metal Fan Box with Round Hook. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 122.85 | 122.85 | 12.0 | False | None | None | False | None | False | 1474.2 | 0 | 4035380 | 156542 | None | PWD SR V-6 Item No-1.2.1 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 69.3 | 69.3 | 80.0 | False | None | None | False | None | False | 5544.0 | 0 | 4035381 | 156542 | None | PWD SR V-6 Item No-1.2.2 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 81.9 | 81.9 | 50.0 | False | None | None | False | None | False | 4095.0 | 0 | 4035382 | 156542 | None | PWD SR V-6 Item No-1.1.1 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 72.45 | 72.45 | 60.0 | False | None | None | False | None | False | 4347.0 | 0 | 4035383 | 156542 | None | PWD SR V-6 Item No-1.1.2 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 85.05 | 85.05 | 30.0 | False | None | None | False | None | False | 2551.5 | 0 | 4035384 | 156542 | None | PWD SR V-6 Item No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 27.3 | 27.3 | 125.0 | False | None | None | False | None | False | 3412.5 | 0 | 4035385 | 156542 | None | PWD SR V-6 Item No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 44.1 | 44.1 | 200.0 | False | None | None | False | None | False | 8820.0 | 0 | 4035386 | 156542 | None | PWD SR V-6 Item No-2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 66.15 | 66.15 | 100.0 | False | None | None | False | None | False | 6615.0 | 0 | 4035387 | 156542 | None | PWD SR V-6 Item No-5.19.4 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & N ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 1956.15 | 1956.15 | 2.0 | False | None | None | False | None | False | 3912.3 | 0 | 4035388 | 156542 | None | PWD SR V-6 Item No-5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 435.75 | 435.75 | 20.0 | False | None | None | False | None | False | 8715.0 | 0 | 4035389 | 156542 | None | PWD SR V-6 Item No-5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 775.95 | 775.95 | 1.0 | False | None | None | False | None | False | 775.95 | 0 | 4035390 | 156542 | None | PWD SR V-6 Item No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 9717.75 | 9717.75 | 2.0 | False | None | None | False | None | False | 19435.5 | 0 | 4035391 | 156542 | None | PWD SR V-6 Item No-5.20.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 pole ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 4490.85 | 4490.85 | 2.0 | False | None | None | False | None | False | 8981.7 | 0 | 4035392 | 156542 | None | PWD SR V-6 Item No-11.3.1 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 578.55 | 578.55 | 6.0 | False | None | None | False | None | False | 3471.3 | 0 | 4035393 | 156542 | None | PWD SR V-6 Item No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 724.5 | 724.5 | 29.0 | False | None | None | False | None | False | 21010.5 | 0 | 4035394 | 156542 | None | PWD SR V-6 Item No-11.11.3 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500K ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 156.45 | 156.45 | 2.0 | False | None | None | False | None | False | 312.9 | 0 | 4035395 | 156542 | None | PWD SR V-6 Item No-11.8.3 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70W ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 6291.6 | 6291.6 | 2.0 | False | None | None | False | None | False | 12583.2 | 0 | 4035396 | 156542 | None | PWD SR V-6 Item No-6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 1566.6 | 1566.6 | 4.0 | False | None | None | False | None | False | 6266.4 | 0 | 4035397 | 156542 | None | PWD SR V-6 Item No-6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 3133.2 | 3133.2 | 11.0 | False | None | None | False | None | False | 34465.2 | 0 | 4035398 | 156542 | None | PWD SR V-6 Item No-12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 66.15 | 66.15 | 19.0 | False | None | None | False | None | False | 1256.85 | 0 | 4035399 | 156542 | None | PWD SR V-6 Item No-13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 128.1 | 128.1 | 37.0 | False | None | None | False | None | False | 4739.7 | 0 | 4035400 | 156542 | None | PWD SR V-6 Item No-13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 330.75 | 330.75 | 11.0 | False | None | None | False | None | False | 3638.25 | 0 | 4035401 | 156542 | None | PWD SR V-6 Item No-13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 742.35 | 742.35 | 4.0 | False | None | None | False | None | False | 2969.4 | 0 | 4035402 | 156542 | None | PWD SR V-6 Item No-13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 1534.05 | 1534.05 | 2.0 | False | None | None | False | None | False | 3068.1 | 0 | 4035403 | 156542 | None | PWD SR V-6 Item No-13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 170.1 | 170.1 | 2.0 | False | None | None | False | None | False | 340.2 | 0 | 4035404 | 156542 | None | PWD V-6 It No: 32.03PgNo: 13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Km | 123904.2 | 123904.2 | 0.15 | False | None | None | False | None | False | 18585.63 | 0 | 4035405 | 156542 | None | PWD V-6 It No: 20.05 PgNo: 52 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other
equipment charges if any)
LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Km | 1246.35 | 1246.35 | 0.15 | False | None | None | False | None | False | 186.9525 | 0 | 4035406 | 156542 | None | PWD V-6 It No: 21.05PgNo: 52 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
LT Cable 2.5 to 25 Sqmm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Km | 21930.3 | 21930.3 | 0.15 | False | None | None | False | None | False | 3289.545 | 0 | 4035407 | 156542 | None | PWD V-6 It No: 51.01PgNo: 22 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer
complete Minimum Weight of GI Pipe: 7.3 Kg ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 780.15 | 780.15 | 2.0 | False | None | None | False | None | False | 1560.3 | 0 | 4035408 | 156542 | None | PWD V-6 It No: 51.02PgNo: 22 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg
each ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 709.8 | 709.8 | 2.0 | False | None | None | False | None | False | 1419.6 | 0 | 4035409 | 156542 | None | PWD V-6 It No: 51.03PgNo: 22 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Bag | 325.5 | 325.5 | 4.0 | False | None | None | False | None | False | 1302.0 | 0 | 4035410 | 156542 | None | PWD V-6 It No: 1.6.2PgNo: 43 | Digging of Pit for providing GI Pipe type Earthing
Hard Soil ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Per Pit | 3139.5 | 3139.5 | 2.0 | False | None | None | False | None | False | 6279.0 | 0 | 4035411 | 156542 | None | PWD SR V-6 Item No-5.42.1 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWG ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sq CM | 0.53 | 0.53 | 10000.0 | False | None | None | False | None | False | 5300.0 | 0 | 4035412 | 156542 | None | PWD SR V-6 Item No-5.40.1 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 2588.25 | 2588.25 | 1.2 | False | None | None | False | None | False | 3105.9 | 0 | 4035413 | 156542 | None | PWD SR V-6 Item No-5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 320.25 | 320.25 | 2.4 | False | None | None | False | None | False | 768.6 | 0 | 4035414 | 156542 | None | PWD SR V-6 Item No-5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 793.8 | 793.8 | 2.4 | False | None | None | False | None | False | 1905.12 | 0 | 4035415 | 156542 | None | PWD SR V-6 Item No-5.44.2 | Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mm ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 6471.15 | 6471.15 | 1.0 | False | None | None | False | None | False | 6471.15 | 0 | 4035416 | 156542 | None | PWD SR V-6 Item No-5.31 | Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Each | 4609.5 | 4609.5 | 2.0 | False | None | None | False | None | False | 9219.0 | 0 |
| 1726813043000 | 0 | None | None | Buildings | Septic Tank | 72397.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035417 | 156543 | None | PWD V- 1 SR 2023-24 Page No-5 It No-1.4.1 | Septic Tank: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 195.3 | 195.3 | 15.56 | False | None | None | False | None | False | 3038.868 | 0 | 4035418 | 156543 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5947.2 | 5947.2 | 0.72 | False | None | None | False | None | False | 4281.984 | 0 | 4035419 | 156543 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tank ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7170.28 | 7170.28 | 0.52 | False | None | None | False | None | False | 3728.5456 | 0 | 4035420 | 156543 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Walls ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7303.07 | 7303.07 | 2.28 | False | None | None | False | None | False | 16650.9996 | 0 | 4035421 | 156543 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Slab ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 9958.73 | 9958.73 | 0.51 | False | None | None | False | None | False | 5078.9523 | 0 | 4035422 | 156543 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | t | 93929.85 | 93929.85 | 0.265 | False | None | None | False | None | False | 24891.41025 | 0 | 4035423 | 156543 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 279.3 | 279.3 | 8.11 | False | None | None | False | None | False | 2265.123 | 0 | 4035424 | 156543 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 292.95 | 292.95 | 22.2 | False | None | None | False | None | False | 6503.49 | 0 | 4035425 | 156543 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.96 | Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 675.15 | 675.15 | 2.4 | False | None | None | False | None | False | 1620.36 | 0 | 4035426 | 156543 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.97.2 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thickness ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3816.75 | 3816.75 | 0.36 | False | None | None | False | None | False | 1374.03 | 0 | 4035427 | 156543 | None | PWD V- 2 SR 2023-24 Page No-127 It No-13.56 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Pit | 2964.15 | 2964.15 | 1.0 | False | None | None | False | None | False | 2964.15 | 0 |
| 1726813043000 | 0 | None | None | Buildings | Sump | 105794.43 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4035428 | 156544 | None | PWD V- 1 SR 2023-24 Page No-5 It No-1.4.1 | Sump: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 254.1 | 254.1 | 9.83 | False | None | None | False | None | False | 2497.803 | 0 | 4035429 | 156544 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5947.2 | 5947.2 | 0.62 | False | None | None | False | None | False | 3687.264 | 0 | 4035430 | 156544 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom Bed ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7170.28 | 7170.28 | 0.52 | False | None | None | False | None | False | 3728.5456 | 0 | 4035431 | 156544 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Walls ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7303.7 | 7303.7 | 1.89 | False | None | None | False | None | False | 13803.993 | 0 | 4035432 | 156544 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Slab ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 9958.73 | 9958.73 | 0.57 | False | None | None | False | None | False | 5676.4761 | 0 | 4035433 | 156544 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | t | 93929.85 | 93929.85 | 0.24 | False | None | None | False | None | False | 22543.164 | 0 | 4035434 | 156544 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Cum | 279.3 | 279.3 | 4.86 | False | None | None | False | None | False | 1357.398 | 0 | 4035435 | 156544 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 292.95 | 292.95 | 18.6 | False | None | None | False | None | False | 5448.87 | 0 | 4035436 | 156544 | None | PWD V- 2 SR 2021-22 Page No-133 It No-15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Kgs | 782.25 | 782.25 | 37.08 | False | None | None | False | None | False | 29005.83 | 0 | 4035437 | 156544 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.96 | Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | m | 675.15 | 675.15 | 2.4 | False | None | None | False | None | False | 1620.36 | 0 | 4035438 | 156544 | None | PWD V- 2 SR 2023-24 Page No-112 It No-12.97.2 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thickness ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 3816.75 | 3816.75 | 0.36 | False | None | None | False | None | False | 1374.03 | 0 | 4035439 | 156544 | None | PWD Bal Cir SR 2018-19 Page No-75 It No-11.45 | KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | Nos | 266.7 | 266.7 | 4.0 | False | None | None | False | None | False | 1066.8 | 0 | 4035440 | 156544 | None | PWD V- 5 SR 2023-24 Page No-149 It No-13.6.1 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STG ---- with all lead and lifts complete as per Specification and as directed by the Engineer in-charge of work | No | 13983.9 | 13983.9 | 1.0 | False | None | None | False | None | False | 13983.9 | 0 |
|
|
---|