4033658 | 156493 | None | code01 | KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 254.1 | 254.1 | 37.71 | False | None | None | False | None | False | 9582.111 | 0 |
4033659 | 156493 | None | code02 | KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 279.3 | 279.3 | 305.69 | False | None | None | False | None | False | 85379.217 | 0 |
4033660 | 156493 | None | code03 | KSRB 2.5 : Earthwork excavation ( in deposited soil ) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per pecifications.specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 254.1 | 254.1 | 377.1 | False | None | None | False | None | False | 95821.11 | 0 |
4033661 | 156493 | None | code04 | KSRB-5.2-2: Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 6708.45 | 6708.45 | 34.56 | False | None | None | False | None | False | 231844.032 | 0 |
4033662 | 156493 | None | code05 | KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. (Excluding cost of steel, fabrication and finishing charges) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 6961.5 | 6961.5 | 73.63 | False | None | None | False | None | False | 512575.245 | 0 |
4033663 | 156493 | None | code06 | KSRB 4.2.7: Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.70cum and fine aggregates @ 0.47cum with superplastisiser @3lts confirming to IS9103- 1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. (Excluding cost of steel, fabrication and finishing charges) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 7185.15 | 7185.15 | 211.51 | False | None | None | False | None | False | 1519731.0765 | 0 |
4033664 | 156493 | None | code07 | KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 443.0 | 443.0 | 290.92 | False | None | None | False | None | False | 128877.56 | 0 |
4033665 | 156493 | None | code08 | KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness Upto 200 mm including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 979.79 | 979.79 | 1312.1 | False | None | None | False | None | False | 1285582.459 | 0 |
4033666 | 156493 | None | code09 | KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1045.11 | 1045.11 | 1400.72 | False | None | None | False | None | False | 1463906.4792 | 0 |
4033667 | 156493 | None | code10 | KSRB 4-6.4: Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth and string courses cost of all materials, labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 696.15 | 696.15 | 28.8 | False | None | None | False | None | False | 20049.12 | 0 |
4033668 | 156493 | None | code11 | KSRB 4-6.11 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Stairs (excluding landing) except spiral staircase including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 949.3 | 949.3 | 170.83 | False | None | None | False | None | False | 162168.919 | 0 |
4033669 | 156493 | None | code12 | KSRB 4-1.6 : Providing and laying in position plain cement concrete of mix M 15 with cement @ 240 kgs, wtih 20mm and down size graded granite metal, coarse aggregate @ 0.878cum and fine aggregate @ 0.459 cum, machine mixed , concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, and plinth and cills including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 7257.0 | 7257.0 | 1.1 | False | None | None | False | None | False | 7982.7 | 0 |
4033670 | 156493 | None | code13 | KSRB 4-6.9 :Providing and removing centering, shuttering, strutting, propping etc., for edges of slabs and breaks in floor, cills, plinth including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 979.79 | 979.79 | 9.6 | False | None | None | False | None | False | 9405.984 | 0 |
4033671 | 156493 | None | code14 | KSRB 4-4.2 : Extra for use of water proofing compound in Cement concrete of mix M20,at one kg of compound per bag of cement. with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 189.0 | 189.0 | 16.03 | False | None | None | False | None | False | 3029.67 | 0 |
4033672 | 156493 | None | code15 | KSRB 4.9.2 : Providing T.M.T. steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Tonne | 93929.85 | 93929.85 | 18.04 | False | None | None | False | None | False | 1694494.494 | 0 |
4033673 | 156493 | None | code16 | Lift charges for steel of all diameters for additional floors over ground floor per floor height of 3.5 m. or part thereof cost of labour, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Tonne | 939.3 | 939.3 | 92.98 | False | None | None | False | None | False | 87336.114 | 0 |
4033674 | 156493 | None | code17 | KSRB-6.1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5 Newton per sqmm with cement mortar 1:6 including cost of materials, labour charges, scafflolding, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 8367.45 | 8367.45 | 161.91 | False | None | None | False | None | False | 1354773.8295 | 0 |
4033675 | 156493 | None | code18 | KSRB 6-7.4 :Construction of partition wall 11.2 cms thick with non-modular table moulded burnt bricks of class designation 50 with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications.Specification No. KBS 6.2 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 814.8 | 814.8 | 708.33 | False | None | None | False | None | False | 577147.284 | 0 |
4033676 | 156493 | None | code19 | Providing and fixing modular partition consisting of 75 mm thick MS CRCA frames powder coated, tile based system frame, 8 mm thick MDF covered with Fabric of approved colour for Top file finish, 5 mm thick clear ordinary glass both side Middle tile finish, or 8mm thick MDF covered with Fabric of approved colour for Middle tile finish, 9mm thick Laminate tile of approved colour for Bottom tile finish, Continuous skirting level raceway will be provided. as per specifications, drawings with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 5380.0 | 5380.0 | 73.95 | False | None | None | False | None | False | 397851.0 | 0 |
4033677 | 156493 | None | code20 | KSRB-9.4-2: Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 144977.7 | 144977.7 | 2.32 | False | None | None | False | None | False | 336348.264 | 0 |
4033678 | 156493 | None | code21 | Providing & fixing of glazed 3 Track - 2 Panel Sliding Door made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized iron profiles through out the window. The Sliding outer frame having a overall size of 60x45 mm with reinforcement of 1 mm thickness, super sas with overal size of 39x75 mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 20x18 mm and coestruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Window/Door shall be provided with 6 mm plain float glass, standard hardware & multi point locking system of patio espagnolette. Wall thickness of frame, mullion & sash shall be 2-2.2 mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 7070.7 | 7070.7 | 7.5 | False | None | None | False | None | False | 53030.25 | 0 |
4033679 | 156493 | None | code22 | KSRB-9.9-2: Providing and fixing in position Honne wood half panelled and half glazed shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with beading 15mm wide and thickness of finish with the shutters surface including cost of materials, labour, HOM of machineries complete as specifications. (excluding cost of fixtures) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 7816.2 | 7816.2 | 42.68 | False | None | None | False | None | False | 333595.416 | 0 |
4033680 | 156493 | None | code23 | Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tibe of 19 gauge. The door frame to be fixed to be wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 333.9 | 333.9 | 71.4 | False | None | None | False | None | False | 23840.46 | 0 |
4033681 | 156493 | None | code24 | PVC DOOR SHUTTER : Supply and fixing of door shutters made of rigid PVC extruded hollow section of 20mm x 200mm with the wall thickness of 1.0mm + / 0.01mm equally divided into 4nos with tongue and groove locking arrangements. The shutter frame is made of 58x24 mm with the wall thickness of 1.5mm+/-0.15 mm section metricut and joined at 4 corners 125 mmx225mm plastic brackets. The shutter shall be horizonatally reinforced with 2nos of 8mm PVC rods. Teak wood battoms shall be reinforced inside the door shutter during the fabrication of the door shutter at those points wherever the hardware is fixed on to the door shutter with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 3364.2 | 3364.2 | 18.9 | False | None | None | False | None | False | 63583.38 | 0 |
4033682 | 156493 | None | code25 | Providing & fixing of glazed Openable Window made out of multi Chambered uPVC sections with TPV gaskets having Isolated drainage and reinforced with Galvanized iron profiles throughout the window. The outer frame having a overall size of 60x45 mm with reinforcement of 1 mm thickness, mullion with overall size of 75x60 mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 34x20mm and coextructed with gasket. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system of flush lock. Wall thickness of frame & sash shall be 2-2.2 mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 6365.1 | 6365.1 | 71.1 | False | None | None | False | None | False | 452558.61 | 0 |
4033683 | 156493 | None | code26 | KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding Nos 458.43 frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 1066.8 | 1066.8 | 25.0 | False | None | None | False | None | False | 26670.0 | 0 |
4033684 | 156493 | None | code27 | KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Kgs | 176.4 | 176.4 | 1493.1 | False | None | None | False | None | False | 263382.84 | 0 |
4033685 | 156493 | None | code28 | Providing and fixing 304 grade stainless steel hand rails of 14 guaga pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @ 1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mmm dia MS base plates 10mm guage for fixing of vertical pipes 4 Nos anchor bolts & 40 mm dia pipes are fixed horizontal for 2 rows top one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2 rows below top measure @ equal intervals are fixed horizontal cuttting welding bending wherever necessary with suitable caps @ tops bottoms, bending wherever necessary with suitable caps @ tops bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials labour for all items of work HOM of equipment with all lead and lift loading and unloading transportation charges and all other incidental charges etc., complete as per specifications and directions of the Engineer- in - charges of the owrk Ramps or Staircase for Physically challenged with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 593.25 | 593.25 | 39.06 | False | None | None | False | None | False | 23172.345 | 0 |
4033686 | 156493 | None | code29 | KSRB-14.9-1: Providing and laying M-15 cement concrete flooring, 50mm thick with metallic concrete hardner topping, under layer of 35mm thick m-15 cement concrete using broken granite metal of 20mm and down size, and top layer 50mm thick of metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with which metallic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement and 1 part of metallic floor hardening compound of approved quality by wt), including finishing cost of materials, labour, curing, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 840.0 | 840.0 | 820.0 | False | None | None | False | None | False | 688800.0 | 0 |
4033687 | 156493 | None | code30 | KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1129.8 | 1129.8 | 55.32 | False | None | None | False | None | False | 62500.536 | 0 |
4033688 | 156493 | None | code31 | KSRB 14-17.2 : Providing skirting, dado, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately ) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1461.6 | 1461.6 | 78.06 | False | None | None | False | None | False | 114092.496 | 0 |
4033689 | 156493 | None | code32 | Providing vitrified tiles 60 X 60cms of approved make, shade and size for flooring laid on a bed of 12mm thick cement mortar 1:3 mix, flush pointing with white cement using colour pigment, including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1230.6 | 1230.6 | 728.96 | False | None | None | False | None | False | 897058.176 | 0 |
4033690 | 156493 | None | code33 | Providing and laying Hassan Green granite flooring for staircase, treads and rises using pre polished 20 mm thick water cut green Granite slab laid over existing cement concrete bed in CM 1:3, average 20mm thick including full rounding fornosing , cutting 3 line grooves not more than 2 mm wide for antiskidding, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 2994.6 | 2994.6 | 134.28 | False | None | None | False | None | False | 402114.888 | 0 |
4033691 | 156493 | None | code34 | KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 267.75 | 267.75 | 3032.01 | False | None | None | False | None | False | 811820.6775 | 0 |
4033692 | 156493 | None | code35 | KSRB15-3.4 : Providing 15mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 309.75 | 309.75 | 3214.71 | False | None | None | False | None | False | 995756.4225 | 0 |
4033693 | 156493 | None | code36 | KSRB15-3.9 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 371.7 | 371.7 | 1034.45 | False | None | None | False | None | False | 384505.065 | 0 |
4033694 | 156493 | None | code37 | KSRB 8.7-1 : Providing and fixing in position 10mm thick plaster of paris (Gypsum anhydrous) for ceiling flat surface upto a height of 5 m above floor level first class teakwood strips 25mm / 6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to metal frames including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1229.55 | 1229.55 | 737.33 | False | None | None | False | None | False | 906584.1015 | 0 |
4033695 | 156493 | None | code38 | KSRB15-7 : Providing lime rendering for plastering to wall and ceiling , including cost of materials, labour, curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 25.0 | 25.0 | 4797.6 | False | None | None | False | None | False | 119940.0 | 0 |
4033696 | 156493 | None | code39 | KSRB15-16.1 : Providing and finishing external walls in two coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. -do- with primer with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 93.45 | 93.45 | 1034.45 | False | None | None | False | None | False | 96669.3525 | 0 |
4033697 | 156493 | None | code40 | KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after throughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 103.95 | 103.95 | 2255.15 | False | None | None | False | None | False | 234422.8425 | 0 |
4033698 | 156493 | None | code41 | KSRB 15.13.3: Providing and applying two coats dry distemper of of approved brand, and shade on wall surface including priming coat and whitening after throughly brooming the surface to remove all dirt, dust, mortar drops and other foreign matter including preparing the surface, even and sand paper smooth, cost of materials, labour, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 113.4 | 113.4 | 2542.46 | False | None | None | False | None | False | 288314.964 | 0 |
4033699 | 156493 | None | code42 | KSRB 15-18.2 : Providing and applying enamel metal paint two coats (excluding priming coat) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter,including cost of materials, labour, with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 145.95 | 145.95 | 1493.1 | False | None | None | False | None | False | 217917.945 | 0 |
4033700 | 156493 | None | code43 | KSRB 15-17.16 : Providing and applying painting two coats (excluding priming coat) on new wood surface and / or wood based surface with coal tar paint to give an even shade after cleaning the surface of all dirt, dust and foreign matter, including cost of materials, labour,with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 144.9 | 144.9 | 2.32 | False | None | None | False | None | False | 336.168 | 0 |
4033701 | 156493 | None | code44 | KSRB 11-6 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type,S-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay low level, flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. Specification No. KBS 11 | Each | 6275.85 | 6275.85 | 14.0 | False | None | None | False | None | False | 87861.9 | 0 |
4033702 | 156493 | None | code45 | KSRB 11-7.1 : Providing and fixing white vitreous china clay, flat back, lipped front urinal basin of 430x260x350mm with 5 litres PVC automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 with all lead and lift etc with all lead and lift etc complete as per specifications and as directed by engineer in charge. and direction of engineer in charge. | Unit | 4676.7 | 4676.7 | 6.0 | False | None | None | False | None | False | 28060.2 | 0 |
4033703 | 156493 | None | code46 | KSRB 11-11.5 : Providing and fixing white vitreous china clay, flat back wash basin size 450x300mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. Specification No. KBS 11 | Unit | 3009.3 | 3009.3 | 6.0 | False | None | None | False | None | False | 18055.8 | 0 |
4033704 | 156493 | None | code47 | Plumbing : KSRB 2-22 : Earthwork excavation for foundation of buildings water supply sanitary lines and electrical conduits either in pits or in trenches 15m and above in width in hard soil not exceeding 15 m in depth including dressing the bottom and sides of pits and trenches stacking the excavated soil clear from edges of excavation with lead upto 50 m after breaking of clods with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 275.1 | 275.1 | 168.0 | False | None | None | False | None | False | 46216.8 | 0 |
4033705 | 156493 | None | code48 | KSRB 2-4 : Refilling available earth around pipe lines cables in layers not exceeding 20cms in depth compacting each deposited layer by ramming after watering with lead upto 50m and lift upto 15 m including cost of all labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 168.0 | 168.0 | 160.0 | False | None | None | False | None | False | 26880.0 | 0 |
4033706 | 156493 | None | code49 | KSRB13-61-2 : Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 241.5 | 241.5 | 120.0 | False | None | None | False | None | False | 28980.0 | 0 |
4033707 | 156493 | None | code50 | KSRB13-62-1 : Providing and fixing in position brass stop cock of approved quality 15mm nominal bore including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 313.95 | 313.95 | 50.0 | False | None | None | False | None | False | 15697.5 | 0 |
4033708 | 156493 | None | code51 | KSRB13-63-3 : Providing and fixing in position brass gate valve with CI wheel of approved quality ( screwed end ) 25mm nominal bore including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 576.45 | 576.45 | 13.0 | False | None | None | False | None | False | 7493.85 | 0 |
4033709 | 156493 | None | code52 | KSRB13-63-5 : Providing and fixing in position brass gate valve with CI wheel of approved quality ( screwed end ) 40mm nominal bore including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 737.1 | 737.1 | 6.0 | False | None | None | False | None | False | 4422.6 | 0 |
4033710 | 156493 | None | code53 | KSRB13-63-6 : Providing and fixing in position brass gate valve with CI wheel of approved quality ( screwed end ) 50mm nominal bore including cost of all materials labour and HOM of equipments with all leads with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 897.75 | 897.75 | 7.0 | False | None | None | False | None | False | 6284.25 | 0 |
4033711 | 156493 | None | code54 | KSRB13-64-3 : Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 25mm nominal bore including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 348.6 | 348.6 | 16.0 | False | None | None | False | None | False | 5577.6 | 0 |
4033712 | 156493 | None | code55 | KSRB13-66-1 : Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 300 mm length of PVC connection including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Set | 87.15 | 87.15 | 12.0 | False | None | None | False | None | False | 1045.8 | 0 |
4033713 | 156493 | None | code56 | KSRB13-66-2 : Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials labour and HOM of equipments with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Set | 95.55 | 95.55 | 25.0 | False | None | None | False | None | False | 2388.75 | 0 |
4033714 | 156493 | None | code57 | Providing & fixing chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778 having thermal stablity for hot & cold water supply including all CPVC plain and brass threaded fitting including fixing the pipe with clamp with clamps at 100 meter spacingThis include jointing of pipes and fitting with one step CPVC solvent cement and testing of joints complete ( internal work exposed on wall) 25 mm nominal OD pipe with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 333.9 | 333.9 | 500.0 | False | None | None | False | None | False | 166950.0 | 0 |
4033715 | 156493 | None | code58 | Providing & fixing chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778 having thermal stablity for hot & cold water supply including all CPVC plain and brass threaded fitting including fixing the pipe with clamp with clamps at 100 meter spacingThis include jointing of pipes and fitting with one step CPVC solvent cement and testing of joints complete ( internal work exposed on wall)(P-84 I-1385) 32 mm nominal OD pipe (P-104 I-13853) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 420.0 | 420.0 | 800.0 | False | None | None | False | None | False | 336000.0 | 0 |
4033716 | 156493 | None | code59 | Providing & fixing chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778 having thermal stablity for hot & cold water supply including all CPVC plain and brass threaded fitting including fixing the pipe with clamp with clamps at 100 meter spacingThis include jointing of pipes and fitting with one step CPVC solvent cement and testing of joints complete ( internal work exposed on wall) 40 mm nominal OD pipe with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 562.8 | 562.8 | 135.0 | False | None | None | False | None | False | 75978.0 | 0 |
4033717 | 156493 | None | code60 | KSRB 11-151 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with CP screws washers including cost of materials labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Unit | 1281.0 | 1281.0 | 18.0 | False | None | None | False | None | False | 23058.0 | 0 |
4033718 | 156493 | None | code61 | KSRB 11-17-1 : Providing and fixing CP brass towel rail 740mm length 20mm dia with CP brackets fixed to wooden cleats with CP brass screws including cost of materials labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Unit | 520.8 | 520.8 | 14.0 | False | None | None | False | None | False | 7291.2 | 0 |
4033719 | 156493 | None | code62 | Providing and fixing 75 cms to 1500 cms dia NP grating 100 mm dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 68.25 | 68.25 | 50.0 | False | None | None | False | None | False | 3412.5 | 0 |
4033720 | 156493 | None | code63 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot) -do- 10cms x 75cms with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 231.0 | 231.0 | 25.0 | False | None | None | False | None | False | 5775.0 | 0 |
4033721 | 156493 | None | code64 | Drilling holes of 250 cms dia (roof/chajja/sTonnee) - -do- in slabs upto 750 cms thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 79.0 | 79.0 | 38.0 | False | None | None | False | None | False | 3002.0 | 0 |
4033722 | 156493 | None | code65 | Drilling holes of 250 cms dia (roof/chajja/sTonnee) -do- in slabs upto 10 cms thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 95.0 | 95.0 | 15.0 | False | None | None | False | None | False | 1425.0 | 0 |
4033723 | 156493 | None | code66 | Wall bores in Brick masonry upto 45 cm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 78.0 | 78.0 | 40.0 | False | None | None | False | None | False | 3120.0 | 0 |
4033724 | 156493 | None | code67 | Wall bores in size sTonnee masonry -do- upto 45 cm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 187.0 | 187.0 | 15.0 | False | None | None | False | None | False | 2805.0 | 0 |
4033725 | 156493 | None | code68 | KSRB 13-111 : Providing and placing on terrace polyethylene water storage tanks with manhole lid and suitable locking arrangements making holes of suitable diameter for inlet outlet and over flow pipes including cost of all materials labour transport charges HOM of equipments and testing complete as per specifications(For 1000 litre capacity) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 8467.0 | 8467.0 | 5.0 | False | None | None | False | None | False | 42335.0 | 0 |
4033726 | 156493 | None | code69 | Submersible Pump with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 50000.0 | 50000.0 | 2.0 | False | None | None | False | None | False | 100000.0 | 0 |
4033727 | 156493 | None | code70 | Providing and fixing to wall ceiling and floor unplasticised PVC pipes 1000 kgf/sqcm working pressure chemp plast / wavin or equivalent make with pipe fitings wall clipsmaking good the wall ceiling and floor including cost of all materials labour charges HOM of equipments and testing complete as per specifications do with 160mm outer dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 604.8 | 604.8 | 600.0 | False | None | None | False | None | False | 362880.0 | 0 |
4033728 | 156493 | None | code71 | Providing and fixing to wall ceiling and floor unplasticised PVC pipes 1000 kgf/sqcm working pressure chemp plast / wavin or equivalent make with pipe fitings wall clipsmaking good the wall ceiling and floor including cost of all materials labour charges HOM of equipments and testing complete as per specifications do with 110mm outer dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 302.4 | 302.4 | 135.0 | False | None | None | False | None | False | 40824.0 | 0 |
4033729 | 156493 | None | code72 | KSRB 12-55 : Constructing brick masonry circular type manhole 152 m internal dia at bottom 230m deep and 056m dia at top with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4 inside cement plaster 12mm thick with cement mortar 1:3 finished with a floating coat of neat cement foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal finished with a floating coat of neat cement with SFRC cover and frame ( heavy duty HD-20 grade designation) 560mm internal diameter confirming to IS :12592 total weight length of cover and frame to be not less than 182 kg fixed in cement concrete M 15 20mm and down size broken granite metal providing and removing centering shuttering including cost of materials labour charges HOM of mechineries complete as per specifications ( Excavation footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 111017.55 | 111017.55 | 2.0 | False | None | None | False | None | False | 222035.1 | 0 |
4033730 | 156493 | None | code73 | KSRB 12-61 : Providing 20mm square MS footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms using 20mm and down size metal of size including cost of materials labour charges curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 244.0 | 244.0 | 46.0 | False | None | None | False | None | False | 11224.0 | 0 |
4033731 | 156493 | None | code74 | KSRB 12-52 : Constructing brick masonry circular type manhole 167 m internal dia at bottom 091m deep and 056m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4 inside cement plastered 12mm thick with cement mortar 1:3 finished with a floating coat of neat cement foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement with SFRC cover and frame ( heavy duty HD-20 grade designation) 560mm internal diametre confirming IS :12592 total weight cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 20mm and downsize broken granite metal providing and removing centering shuttering including cost of materials labour charges HOM of mechineries complete as per specifications (Excavation footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 41623.05 | 41623.05 | 3.0 | False | None | None | False | None | False | 124869.15 | 0 |
4033732 | 156493 | None | code75 | Constructing brick masonry inspection chamber 455x610mm and 450mm depth ( clear inside dimension ) for single pipeline using table moulded non-modular bricks of class designation 50 in cement mortar 1:5 CI cover withframe (light duty) 455x610mm internal dimensions total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) RCC top slab with cement concrete M 15 with 20mm and downsize granite metal foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3 finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials labour charges curing complete as per specifications Specification No KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline using table moulded non-modular bricks of class designation 50 in cement mortar 1:5 CI cover withframe (light duty) 600x600mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 5924.1 | 5924.1 | 30.0 | False | None | None | False | None | False | 177723.0 | 0 |
4033733 | 156493 | None | code76 | Constructing brick masonry inspection chamber 455x610mm and 450mm depth ( clear inside dimension ) for single pipeline using table moulded non-modular bricks of class designation 50 in cement mortar 1:5 CI cover withframe (light duty) 455x610mm internal dimensions total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) RCC top slab with cement concrete M 15 with 20mm and downsize granite metal foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3 finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials labour charges curing complete as per specifications Specification No KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline using table moulded non-modular bricks of class designation 50 in cement mortar 1:5 CI cover withframe (light duty) 450x450mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 6591.9 | 6591.9 | 40.0 | False | None | None | False | None | False | 263676.0 | 0 |
4033734 | 156493 | None | code77 | Electrical : Concealed Conduit System Supplying heavy gauge PVC condiuit pipe ……mm dia mm thick confirming to IS 2509 woth suitable size bends metal/PVC junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 69.3 | 69.3 | 1470.0 | False | None | None | False | None | False | 101871.0 | 0 |
4033735 | 156493 | None | code78 | Concealed Conduit System Supplying heavy gauge PVC condiuit pipe ……mm dia mm thick confirming to IS 2509 woth suitable size bends metal/PVC junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 81.9 | 81.9 | 960.0 | False | None | None | False | None | False | 78624.0 | 0 |
4033736 | 156493 | None | code79 | Concealed Conduit System Supplying heavy gauge PVC condiuit pipe ……mm dia mm thick confirming to IS 2509 woth suitable size bends metal/PVC junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 32mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 108.15 | 108.15 | 390.0 | False | None | None | False | None | False | 42178.5 | 0 |
4033737 | 156493 | None | code80 | Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe …dia …mm thick with suitable size bends metal junction boxes adhesive paste etx by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary 19/20mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 71.4 | 71.4 | 300.0 | False | None | None | False | None | False | 21420.0 | 0 |
4033738 | 156493 | None | code81 | Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe …dia …mm thick with suitable size bends metal junction boxes adhesive paste etx by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary25mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 82.95 | 82.95 | 220.0 | False | None | None | False | None | False | 18249.0 | 0 |
4033739 | 156493 | None | code82 | Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe …dia …mm thick with suitable size bends metal junction boxes adhesive paste etx by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary 32mm dia 2.5mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 103.95 | 103.95 | 103.0 | False | None | None | False | None | False | 10706.85 | 0 |
4033740 | 156493 | None | code83 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x15Sqmm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet Group A Short point up to 3Mtr from tapping point to out let via switch with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Point | 299.25 | 299.25 | 14.0 | False | None | None | False | None | False | 4189.5 | 0 |
4033741 | 156493 | None | code84 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x15Sqmm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet Group A Medium point above 3mtr upto 6Mtr from tapping point to out let via switch with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Point | 413.7 | 413.7 | 43.0 | False | None | None | False | None | False | 17789.1 | 0 |
4033742 | 156493 | None | code85 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x15Sqmm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet Group A Long point above 6Mtr upto 10Mtr from tapping point to out let via switch with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Point | 598.5 | 598.5 | 99.0 | False | None | None | False | None | False | 59251.5 | 0 |
4033743 | 156493 | None | code86 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A 15 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 27.3 | 27.3 | 720.0 | False | None | None | False | None | False | 19656.0 | 0 |
4033744 | 156493 | None | code87 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A 25 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 44.1 | 44.1 | 1340.0 | False | None | None | False | None | False | 59094.0 | 0 |
4033745 | 156493 | None | code88 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A 4 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 66.15 | 66.15 | 1075.0 | False | None | None | False | None | False | 71111.25 | 0 |
4033746 | 156493 | None | code89 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A 6 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 96.6 | 96.6 | 190.0 | False | None | None | False | None | False | 18354.0 | 0 |
4033747 | 156493 | None | code90 | Supplying and mounting 2 Nos of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required Is 1293 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 178.5 | 178.5 | 4.0 | False | None | None | False | None | False | 714.0 | 0 |
4033748 | 156493 | None | code91 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 (15/31) 6Amps 3/5 Way with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 154.35 | 154.35 | 65.0 | False | None | None | False | None | False | 10032.75 | 0 |
4033749 | 156493 | None | code92 | Supply and fixing of bakelite DP/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per 1293 and IS 3854 Group A 16Amps Flush type Universal socket with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 247.8 | 247.8 | 16.0 | False | None | None | False | None | False | 3964.8 | 0 |
4033750 | 156493 | None | code93 | Supply and fixing of bakelite DP/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per 1293 and IS 3854Group A 32Amps Flush/projected type DP switch with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 342.3 | 342.3 | 16.0 | False | None | None | False | None | False | 5476.8 | 0 |
4033751 | 156493 | None | code94 | Supplying of 4 feet - LED PVC Square Batten W with high quality diffuser with life of 25000 burning hours & 70Percentage lumen maintenance with CRI greater than 80. Power input : 220-240v @50Hz & power factor greater than 0.9 alongwith CE approved drivers 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 4 - 28 watts with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1862.7 | 1862.7 | 4.0 | False | None | None | False | None | False | 7450.8 | 0 |
4033752 | 156493 | None | code95 | Supplying patti type flourescent tube light fitting of 2-suitable for 14 watts flourescent tube fitting made out of MS sheet and stove enamelled with HF Electronic Ballast locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 volts AC Supply including T5 lamp with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 620.55 | 620.55 | 4.0 | False | None | None | False | None | False | 2482.2 | 0 |
4033753 | 156493 | None | code96 | Supply of 2x2 LED recessed luminaire with… Watts system wattage Husing shall be with pressure die catt aluminium alloy with corrosing proof resistant polyester powder coated Driver operates with voltagerange from 100v to 270V 50/60 Hz with short circuit overload & mis-wring protection Lumen maintenance of 70Percentage at 50000 Hrs injection moulded poly carboanate diffuser for better mechanical stability light transmission & avoid pot hole effect Junction temperature shall be less than 70 degree Celsius Driver is on constant current driver at 0.06A with PF greater than 0.92 line voltage @ 220-240v at 50Hz driver efficiency greater than 85 Percentage & THD less than 15Percentage LED Efficiency greater than 130 lm/W & Fixture Efficiency greater than 75lm/w with CRI greater than 75 with injection moulded Polycarbonate lens with less than 80mm depth 5 years Warranty against any manufacturing defect working under standard electrical condition LED Modular downlight 2x2 36 watts with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4780.65 | 4780.65 | 74.0 | False | None | None | False | None | False | 353768.1 | 0 |
4033754 | 156493 | None | code97 | Supply of 1x1 LED recessed lumisanaire with… Watts system wattage Husing shall be with pressure die catt aluminium alloy with corrosing proof resistant polyester powder coated Driver operates with voltagerange from 100v to 270V 50/60 Hz with short circuit overload & mis-wring protection Lumen maintenance of 70Percentage at 50000 Hrs injection moulded poly carboanate diffuser for better mechanical stability light transmission & avoid pot hole effect Junction temperature shall be less than 70 degree Celsius Driver is on constant current driver at 0.06A with PF greater than 0.9 line voltage @220-240v at 50/60Hz driver efficiency greater than 85Percentage & THD less than 15Percentage LED Efficiency greater than 130 lm/W & Fixture Efficiency greater than 75lm/w with CRI greater than 75 with injection moulded Polycarbonate lens with less than 80mm depth 5 years Warranty against any manufacturing defect working under standard electrical condition (26/433) LED Modular downlight LED Modular downlight 1x136 watts with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 6192.9 | 6192.9 | 22.0 | False | None | None | False | None | False | 136243.8 | 0 |
4033755 | 156493 | None | code98 | Supply of LED Recessed Downlighter with 18W System wattage Housing shall be with powder coated pressure die cast aluminium alloy with corrosion resistant polyester powder coat & with extended heat sink Diffuser/cover made of Lexan plastic material Rated life shall be L70 at 50000 Hrs which shall has inbuilt electrical protection like over/under voltage short circuit overload open circuit & miswiring Driver is on constant current out put driver at 0.06A with PF greater than 0.9 line voltage @220-240v 50/60 Hz driver efficiency greater than 85Percentage & THD less than 15Percentage LED Efficiency greater than 130 Im/W & Fixture Efficiency greater than 75lm/w with CRI greater than 75 with injection moulded Polycarbonate lens 5 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lift etc complete as per specifications and direction of engineer in charge. | Each | 3294.9 | 3294.9 | 10.0 | False | None | None | False | None | False | 32949.0 | 0 |
4033756 | 156493 | None | code99 | Supplying and fixing PBBC/bakelite straight or slant batten holder and wiring within 60w/230 Volts lamps with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 77.7 | 77.7 | 24.0 | False | None | None | False | None | False | 1864.8 | 0 |
4033757 | 156493 | None | code100 | Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076 twin twisted PVC insulated wires required Nos of round blocks and clamps On wall/ceiling/Rafter/Girders with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 128.1 | 128.1 | 169.0 | False | None | None | False | None | False | 21648.9 | 0 |
4033758 | 156493 | None | code101 | Supplying of LED Floodlight with 150W System Power consumption pressure die cast aluminium housing with powder coating with IP 65 protection 1 200-275V voltage with electronic Driver PF greater than 0.9 should meet ANSI 2G Vibration test Compliance to UL/CE with Class I Slystem rating shall be 50K hrs at Lumen maintenance of 70Percentage system efficacy greater than 80lm/w Over lad & Short circuit protection protection ensures reliable operation in spite of problem in output side Conmpliance to IS 10322/IEC 60598 LM 79 & LM 80 Adherence with RoHS UL approved MCPCB top access street light with single screw to ensure ease of maintenance at street light with single screw to ensure ease of maintenance at the sight site loation with minimized minimal tools LED light fixture with W System power consumption LED Efficiency greater than 130lm/w with nominal CRI greater than 75 Luminaire manufacturer should nave inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facitlity certified by ISO 9001:2008 Housing With supplier word mark /name shall be Engraved /Embossing on the die cast housing/Body part Warranty of years against any manufacturing defct working under years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 13114.5 | 13114.5 | 4.0 | False | None | None | False | None | False | 52458.0 | 0 |
4033759 | 156493 | None | code102 | Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 volts 50 cycles Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200mm) Regular model with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3133.2 | 3133.2 | 30.0 | False | None | None | False | None | False | 93996.0 | 0 |
4033760 | 156493 | None | code103 | Supplyin and Fixing Metal Fan Box with Round Hook(3/112) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 122.85 | 122.85 | 30.0 | False | None | None | False | None | False | 3685.5 | 0 |
4033761 | 156493 | None | code104 | Supply and fixing of bakelite DP/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per 1293 and IS 3854 Group 32A Electronic stepped regulator with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos. | 342.3 | 342.3 | 30.0 | False | None | None | False | None | False | 10269.0 | 0 |
4033762 | 156493 | None | code105 | Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5amps Ceiling rose necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 179.55 | 179.55 | 30.0 | False | None | None | False | None | False | 5386.5 | 0 |
4033763 | 156493 | None | code106 | Supplying of 1440rpm heavy duty Exhaust fan with bracket blades suitable to operate on 230V 50Hz AC Supply complete 12" Sweep (300mm) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3117.45 | 3117.45 | 8.0 | False | None | None | False | None | False | 24939.6 | 0 |
4033764 | 156493 | None | code107 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps Ceiling rose wisth sufficient length of 23/00076 inch PVC insulated twincore wire with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 516.6 | 516.6 | 8.0 | False | None | None | False | None | False | 4132.8 | 0 |
4033765 | 156493 | None | code108 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws(104/162) Remote with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 258.3 | 258.3 | 2.0 | False | None | None | False | None | False | 516.6 | 0 |
4033766 | 156493 | None | code109 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/STonnee/CC wall CELLAR FLOOR 12WAY with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 212.43 | 212.43 | 6.0 | False | None | None | False | None | False | 1274.58 | 0 |
4033767 | 156493 | None | code110 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/STonnee/CC wall GROUND FLOOR 1-3Way with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 74.08 | 74.08 | 3.0 | False | None | None | False | None | False | 222.24 | 0 |
4033768 | 156493 | None | code111 | 6Way | Each | 231.0 | 231.0 | 8.0 | False | None | None | False | None | False | 1848.0 | 0 |
4033769 | 156493 | None | code112 | 8Way | Each | 274.05 | 274.05 | 6.0 | False | None | None | False | None | False | 1644.3 | 0 |
4033770 | 156493 | None | code113 | 10-12Way | Each | 334.95 | 334.95 | 35.0 | False | None | None | False | None | False | 11723.25 | 0 |
4033771 | 156493 | None | code114 | 16Way | Each | 425.25 | 425.25 | 4.0 | False | None | None | False | None | False | 1701.0 | 0 |
4033772 | 156493 | None | code115 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal/PVC box CELLAR FLOOR10 MODULE with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 231.61 | 231.61 | 6.0 | False | None | None | False | None | False | 1389.66 | 0 |
4033773 | 156493 | None | code116 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal/PVC box GROUND FLOOR 1 to 3 Module with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 85.69 | 85.69 | 3.0 | False | None | None | False | None | False | 257.07 | 0 |
4033774 | 156493 | None | code117 | 6Moudule | Each | 245.7 | 245.7 | 8.0 | False | None | None | False | None | False | 1965.6 | 0 |
4033775 | 156493 | None | code118 | 8Moudule | Each | 298.2 | 298.2 | 10.0 | False | None | None | False | None | False | 2982.0 | 0 |
4033776 | 156493 | None | code119 | 10Moudule | Each | 361.2 | 361.2 | 2.0 | False | None | None | False | None | False | 722.4 | 0 |
4033777 | 156493 | None | code120 | 12Moudule | Each | 366.45 | 366.45 | 35.0 | False | None | None | False | None | False | 12825.75 | 0 |
4033778 | 156493 | None | code121 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCBs single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS enclosure II - Double Door 8Way SP & N with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1946.7 | 1946.7 | 1.0 | False | None | None | False | None | False | 1946.7 | 0 |
4033779 | 156493 | None | code122 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCBs single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6Way TP & N with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 5187.0 | 5187.0 | 2.0 | False | None | None | False | None | False | 10374.0 | 0 |
4033780 | 156493 | None | code123 | Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5-32Amps SP with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 435.75 | 435.75 | 42.0 | False | None | None | False | None | False | 18301.5 | 0 |
4033781 | 156493 | None | code124 | Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5-32Amps TPN with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1802.85 | 1802.85 | 2.0 | False | None | None | False | None | False | 3605.7 | 0 |
4033782 | 156493 | None | code125 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4490.85 | 4490.85 | 1.0 | False | None | None | False | None | False | 4490.85 | 0 |
4033783 | 156493 | None | code126 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 4 pole with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 5404.35 | 5404.35 | 2.0 | False | None | None | False | None | False | 10808.7 | 0 |
4033784 | 156493 | None | code127 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc complete 14SWG with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 0.53 | 0.53 | 280000.0 | False | None | None | False | None | False | 148400.0 | 0 |
4033785 | 156493 | None | code128 | Supplying and fixing angle iron frame work fabricated out of MS angle iron and MS flat … with bolts washers etc and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 414.75 | 414.75 | 60.0 | False | None | None | False | None | False | 24885.0 | 0 |
4033786 | 156493 | None | code129 | Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm MSflat frame work in existing panel board The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc complete 250 Amps 4x30x6mm Alluminium Strips with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 3606.75 | 3606.75 | 20.0 | False | None | None | False | None | False | 72135.0 | 0 |
4033787 | 156493 | None | code130 | Supplying and running of GI/Copper strips for grounding connections using necessary fixing materials as required 25x3mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Rmtr | 86.1 | 86.1 | 3.0 | False | None | None | False | None | False | 258.3 | 0 |
4033788 | 156493 | None | code131 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50 Hz 12/24v DC with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 |
4033789 | 156493 | None | code132 | Supplying of on load change over over switches 4 poles AC 23Amps duty 415V 50HZ AC Supply 200Amps with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 13891.5 | 13891.5 | 1.0 | False | None | None | False | None | False | 13891.5 | 0 |
4033790 | 156493 | None | code133 | Supplying and Fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws bolts nuts and wiring complete protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947 (icu =lcs) 125-160AMPS 25kA with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 9027.9 | 9027.9 | 1.0 | False | None | None | False | None | False | 9027.9 | 0 |
4033791 | 156493 | None | code134 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses) With AC-23A duty and as per IS-13947 with all lead and lift etc complete as per specifications and as directed by engineer in charge. , 160A | Each | 6613.95 | 6613.95 | 4.0 | False | None | None | False | None | False | 26455.8 | 0 |
4033792 | 156493 | None | code135 | Fixing of Amps TPST/ change over switch/Contactor along with neutral link with screws boltsnuts and wiring using required capacity wires and circuit labeling 100A to 250A TPST with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 469.35 | 469.35 | 4.0 | False | None | None | False | None | False | 1877.4 | 0 |
4033793 | 156493 | None | code136 | Supplying of multi function digital meter with three line back light LCD type display for voltage Current frequency power power factor KVA KWH KVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with communication port and class 0.5s accurancy with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 |
4033794 | 156493 | None | code137 | Supplying fixing and wiring rotary selector switch suitable for Ammeter with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 210.0 | 210.0 | 1.0 | False | None | None | False | None | False | 210.0 | 0 |
4033795 | 156493 | None | code138 | Supplying fixing and wiring rotary selector switch suitable for Voltmeter with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 168.0 | 168.0 | 1.0 | False | None | None | False | None | False | 168.0 | 0 |
4033796 | 156493 | None | code139 | Supplying fixing and wiring Earth Leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based digital readout of percentage leakage current programmable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting on panel board with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 |
4033797 | 156493 | None | code140 | Supplying fixing and wiring 50/5 to 400/5 Amps 5KVA burden Current Transformer Class 0.5 accurecy with Tape wound with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 590.1 | 590.1 | 3.0 | False | None | None | False | None | False | 1770.3 | 0 |
4033798 | 156493 | None | code141 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A 10 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 175.35 | 175.35 | 160.0 | False | None | None | False | None | False | 28056.0 | 0 |
4033799 | 156493 | None | code142 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10/25 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 28.35 | 28.35 | 44.0 | False | None | None | False | None | False | 1247.4 | 0 |
4033800 | 156493 | None | code143 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts bolts and washers 32Amps with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 253.05 | 253.05 | 12.0 | False | None | None | False | None | False | 3036.6 | 0 |
4033801 | 156493 | None | code144 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts bolts and washers 100Amps with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 725.55 | 725.55 | 6.0 | False | None | None | False | None | False | 4353.3 | 0 |
4033802 | 156493 | None | code145 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts and nuts the free ends shall be welded to the pole and the block pipe at top and bottom as required including cost of all materials labour lead and lifts cutting bending wherever necessary wastage and lapping etc complete as per direction of the Engineer - in - charge of work including two coats of approved quality paint over one coat of primer paint with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 1036.35 | 1036.35 | 25.0 | False | None | None | False | None | False | 25908.75 | 0 |
4033803 | 156493 | None | code146 | Supplying fixing wiring earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 290mm thick GI pipe 25 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth The connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI specification 733 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the pipe shall have 16 through holes of 122 mm dia with all lead and lift etc complete as per specifications and as directed byengineer in charge. | Each | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 |
4033804 | 156493 | None | code147 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers etc COPPER Wire 8 SWG with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 78.12 | 78.12 | 230.0 | False | None | None | False | None | False | 17967.6 | 0 |
4033805 | 156493 | None | code148 | Supplying and running of GI/Copper strips for grounding connections using necessary fixing materials as required COPPER STRIP 25 X 6mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 1155.0 | 1155.0 | 30.0 | False | None | None | False | None | False | 34650.0 | 0 |
4033806 | 156493 | None | code149 | Supplying and running of GI/Copper strips for grounding connections using necessary fixing materials as required 600x600x3mm plate for copper strip with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 7792.05 | 7792.05 | 3.0 | False | None | None | False | None | False | 23376.15 | 0 |
4033807 | 156493 | None | code150 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Group A RJ45/ IO outlet with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 353.85 | 353.85 | 28.0 | False | None | None | False | None | False | 9907.8 | 0 |
4033808 | 156493 | None | code151 | Supplying and drawing UTP-CAT 6E LAN cable(85/111) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 39.9 | 39.9 | 1200.0 | False | None | None | False | None | False | 47880.0 | 0 |
4033809 | 156493 | None | code152 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Group A TV/Telephone socket with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 163.8 | 163.8 | 13.0 | False | None | None | False | None | False | 2129.4 | 0 |
4033810 | 156493 | None | code153 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 2 Pair with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 13.65 | 13.65 | 1565.0 | False | None | None | False | None | False | 21362.25 | 0 |
4033811 | 156493 | None | code154 | Supplying and drawisng PVC insulated gas injected physical foam jelly flooded co-oxial TV cableRG-6 with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 46.2 | 46.2 | 220.0 | False | None | None | False | None | False | 10164.0 | 0 |
4033812 | 156493 | None | code155 | Supply of 5 HP 12 stage submersible pump sets suitable for borewel of 150mm dia and confirming to indian standard specification with all lead and lift etc complete as per specifications and as directed by engineer in charge. BWSSB SR , I-13.13.4 | Each | 30278.85 | 30278.85 | 1.0 | False | None | None | False | None | False | 30278.85 | 0 |
4033813 | 156493 | None | code156 | Supply & connecting and commisioning of submersible cable 1X3X25sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 89.25 | 89.25 | 300.0 | False | None | None | False | None | False | 26775.0 | 0 |
4033814 | 156493 | None | code157 | Providing galvanized mild steel tubes heavy clean (C-Class) Confirming to ISI 219 part/1979 with latest ammendments with ISI Mark (one end fitted with preservative cover of size 50mm of TATA Make) with all lead and lift etc complete as per specifications and as directed by engineer in charge. BWSSB SR-,I-13.27 | Mtr | 3202.5 | 3202.5 | 60.0 | False | None | None | False | None | False | 192150.0 | 0 |
4033815 | 156493 | None | code158 | Supplying & erecting of 50mm dia GI collar with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 280.35 | 280.35 | 16.0 | False | None | None | False | None | False | 4485.6 | 0 |
4033816 | 156493 | None | code159 | Supplying & erecting of 50mm dia MS clamp with bolts and nuts with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 840.0 | 840.0 | 8.0 | False | None | None | False | None | False | 6720.0 | 0 |
4033817 | 156493 | None | code160 | Supplying & erecting of 50mm non return valve with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3097.5 | 3097.5 | 1.0 | False | None | None | False | None | False | 3097.5 | 0 |
4033818 | 156493 | None | code161 | Supplying & erecting of 50mm dia GI union with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 471.45 | 471.45 | 1.0 | False | None | None | False | None | False | 471.45 | 0 |
4033819 | 156493 | None | code162 | Supplying & erecting of 50mm dia GI Bend with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 474.6 | 474.6 | 2.0 | False | None | None | False | None | False | 949.2 | 0 |
4033820 | 156493 | None | code163 | Supplying & erecting of 50mm dia GI Plugs with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 133.29 | 133.29 | 4.0 | False | None | None | False | None | False | 533.16 | 0 |
4033821 | 156493 | None | code164 | Supplying & erecting of outdoor type consist of two unit meter boards and panel board unit CELLAR FLOOR Meter box suitable for fixing 3 ETV meters with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 10474.8 | 10474.8 | 1.0 | False | None | None | False | None | False | 10474.8 | 0 |
4033822 | 156493 | None | code165 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. BWSSB SR-2023-24, I-13.32 | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
4033823 | 156493 | None | code166 | Errection of panel board out door type with all lead and lift etc complete as per specifications and as directed by engineer in charge. SR 2014-15 | Each | 525.0 | 525.0 | 1.0 | False | None | None | False | None | False | 525.0 | 0 |
4033824 | 156493 | None | code167 | Supplying of 11 KV LT UG cable having aluminium conductor PVC insulated extruded inner sheathed galvanised steel strip (except 2Cx 10Sqmm wire armoured ) Confirming to IS-3975:1990 ( No of Strip indicated in GTP) & extruded PVC outer sheated armoured cable with specified IS-1554 Part-1:1998 & confirming to the attached GTP of GROUP-A 4C x 10Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 124.74 | 124.74 | 50.0 | False | None | None | False | None | False | 6237.0 | 0 |
4033825 | 156493 | None | code168 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / sTonneeware pipe / on wall / on pole as required CELLAR FLOOR in existing trench / duct 6 sqmm to 16 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 64.39 | 64.39 | 50.0 | False | None | None | False | None | False | 3219.5 | 0 |
4033826 | 156493 | None | code169 | Cable trench excavation, 1000x0.6x0.5=300 Ordinary soil | Cum | 168.0 | 168.0 | 42.0 | False | None | None | False | None | False | 7056.0 | 0 |
4033827 | 156493 | None | code170 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm alround the cable with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 108.15 | 108.15 | 42.0 | False | None | None | False | None | False | 4542.3 | 0 |
4033828 | 156493 | None | code171 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 20"x20"2.5" with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 342.44 | 342.44 | 2.0 | False | None | None | False | None | False | 684.88 | 0 |
4033829 | 156493 | None | code172 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 325mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV 40mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 362.25 | 362.25 | 15.0 | False | None | None | False | None | False | 5433.75 | 0 |
4033830 | 156493 | None | code173 | Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5-32Amps TPN with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1802.85 | 1802.85 | 1.0 | False | None | None | False | None | False | 1802.85 | 0 |
4033831 | 156493 | None | code174 | Suplying & connecting of 1KVAR capacitor with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 434.7 | 434.7 | 1.0 | False | None | None | False | None | False | 434.7 | 0 |
4033832 | 156493 | None | code175 | Supplying fixing wiring earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 290mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth The connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI specification 7.3.3 of IS 7.3.2 using 12mm dia bolts nuts washers and checknuts etc the pipe shall have 16 through holes of 122mm dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 |
4033833 | 156493 | None | code176 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers 8SWG GI with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 20.48 | 20.48 | 20.0 | False | None | None | False | None | False | 409.6 | 0 |
4033834 | 156493 | None | code177 | Supplying fully automatic star-delta starter unit push butTon type with suitable wires 3 contactors one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor Upto 12.5 HP with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 7827.75 | 7827.75 | 1.0 | False | None | None | False | None | False | 7827.75 | 0 |
4033835 | 156493 | None | code178 | 11KV LINE TAPPING TO METERING STATION : Supply and erection of Double Pole TC structural set including all hardwares suitable for 100 to 300KVA transformers etc complete as per the standard technical specification of BESCOM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 33131.7 | 33131.7 | 3.0 | False | None | None | False | None | False | 99395.1 | 0 |
4033836 | 156493 | None | code179 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM H Frame set with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4548.6 | 4548.6 | 3.0 | False | None | None | False | None | False | 13645.8 | 0 |
4033837 | 156493 | None | code180 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM GOS Set 200 Amps Single break with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 9922.5 | 9922.5 | 3.0 | False | None | None | False | None | False | 29767.5 | 0 |
4033838 | 156493 | None | code181 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM Horn Gap Fuse Unit (HG) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1122.45 | 1122.45 | 9.0 | False | None | None | False | None | False | 10102.05 | 0 |
4033839 | 156493 | None | code182 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM Lighting Arrestor 9KV 5KA polymeric type with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4989.6 | 4989.6 | 3.0 | False | None | None | False | None | False | 14968.8 | 0 |
4033840 | 156493 | None | code183 | Supply and erection of …Mtr RCC Pole including earth work etc complete as per the standard technical specification of BESCOM 9Mtr 145Kg WL with all lead and lift etc complete as per specifications and as direc ted by engineer in charge. | Each | 7429.8 | 7429.8 | 5.0 | False | None | None | False | None | False | 37149.0 | 0 |
4033841 | 156493 | None | code184 | Supply and erection of …Mtr PCC Pole including earth work etc complete as per the standard technical specification of BESCOM 9 Mtr with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4721.85 | 4721.85 | 1.0 | False | None | None | False | None | False | 4721.85 | 0 |
4033842 | 156493 | None | code185 | Supply and fixing of……including all Hardwares etc complete as per the standard technical of BESCOM specification GUY Set with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1228.5 | 1228.5 | 3.0 | False | None | None | False | None | False | 3685.5 | 0 |
4033843 | 156493 | None | code186 | Supply and fixing of ……cross arm including all Hardwares complete as per the standard technical specification of BESCOM Horrizontal 50x450x6mm-980mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 678.3 | 678.3 | 15.0 | False | None | None | False | None | False | 10174.5 | 0 |
4033844 | 156493 | None | code187 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM HT ST Support 50x8mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 675.15 | 675.15 | 15.0 | False | None | None | False | None | False | 10127.25 | 0 |
4033845 | 156493 | None | code188 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM RCC Clamp with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 107.1 | 107.1 | 15.0 | False | None | None | False | None | False | 1606.5 | 0 |
4033846 | 156493 | None | code189 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM PCC Clamp with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 107.1 | 107.1 | 1.0 | False | None | None | False | None | False | 107.1 | 0 |
4033847 | 156493 | None | code190 | Supplying and Fixing …including all Hardwares etc complete as per the standard technical specification of BESCOM 11KV Pin insulator with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 215.25 | 215.25 | 27.0 | False | None | None | False | None | False | 5811.75 | 0 |
4033848 | 156493 | None | code191 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM Spl 3 PIN Cross ARM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 922.95 | 922.95 | 1.0 | False | None | None | False | None | False | 922.95 | 0 |
4033849 | 156493 | None | code192 | 45 KN Disc insulators with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 195.3 | 195.3 | 12.0 | False | None | None | False | None | False | 2343.6 | 0 |
4033850 | 156493 | None | code193 | Supplying and Fixing of PGClamp including all Hardwares etc complete as per the standard technical specification of BESCOM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 107.1 | 107.1 | 12.0 | False | None | None | False | None | False | 1285.2 | 0 |
4033851 | 156493 | None | code194 | Supplying and Fixing of Rabbit Conductor(6/315mm Al +6/315mm Steel) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 61.35 | 61.35 | 900.0 | False | None | None | False | None | False | 55215.0 | 0 |
4033852 | 156493 | None | code195 | Supplying and fixing of Spiral Earth Electrodes as per standard technical specification as per BESCOM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 250.95 | 250.95 | 5.0 | False | None | None | False | None | False | 1254.75 | 0 |
4033853 | 156493 | None | code196 | Concreting with material & labour - Base concreting CC 1:4:8 a) Pole Base 9/8 mtrs Pole Supports with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 327.6 | 327.6 | 5.0 | False | None | None | False | None | False | 1638.0 | 0 |
4033854 | 156493 | None | code197 | B) Pole concreting with CC 1:2:4 (without coping) a) 9mtrs support (650x500x1700mm) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4719.75 | 4719.75 | 6.0 | False | None | None | False | None | False | 28318.5 | 0 |
4033855 | 156493 | None | code198 | Providing Coping for Poles with CC 1:2:4 a) 150 mm around poles for a height of 300 mm for RCC PSC PCC Poles/ I - Beam/ Rail Steel sections with all lead and lift etc complete as per specifications and as directed by engineer in charge. | No | 327.6 | 327.6 | 5.0 | False | None | None | False | None | False | 1638.0 | 0 |
4033856 | 156493 | None | code199 | e) Guy concreting as above but with cement concrete of concrete mix M5 with OPC cement at 160 Kgs with all lead and lift etc complete as per specifications and as directed by engineer in charge. | No | 262.5 | 262.5 | 3.0 | False | None | None | False | None | False | 787.5 | 0 |
4033857 | 156493 | None | code200 | Providing guarding at Road Crossings telephone line Crossings(Excluding fixing of necessary cross arms) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Span | 4882.5 | 4882.5 | 1.0 | False | None | None | False | None | False | 4882.5 | 0 |
4033858 | 156493 | None | code201 | Supply and fixing of ……cross arm including all Hardwares complete as per the standard technical specification of BESCOM 4 pin 45x45x5mm-1110mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 444.15 | 444.15 | 2.0 | False | None | None | False | None | False | 888.3 | 0 |
4033859 | 156493 | None | code202 | Supply and fixing of ……cross arm including all Hardwares complete as per the standard technical specification of BESCOM Horrizontal 50x450x6mm-980mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 678.3 | 678.3 | 2.0 | False | None | None | False | None | False | 1356.6 | 0 |
4033860 | 156493 | None | code203 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM HT ST Support 50x8mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 675.15 | 675.15 | 2.0 | False | None | None | False | None | False | 1350.3 | 0 |
4033861 | 156493 | None | code204 | Supplying and Fixing … including all Hardwares etc complete as per the standard technical specification of BESCOM RCC Clamp with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 107.1 | 107.1 | 2.0 | False | None | None | False | None | False | 214.2 | 0 |
4033862 | 156493 | None | code205 | Supply and erection of …Mtr PCC Pole including earth work etc complete as per the standard technical specification of BESCOM 9Mtr 145Kg WL with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4408.95 | 4408.95 | 2.0 | False | None | None | False | None | False | 8817.9 | 0 |
4033863 | 156493 | None | code206 | Supply and fixing of……including all Hardwares etc complete as per the standard technical of BESCOM specification GUY Set with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 1228.5 | 1228.5 | 2.0 | False | None | None | False | None | False | 2457.0 | 0 |
4033864 | 156493 | None | code207 | Concreting with material & labour - Base concreting CC 1:4:8 a) Pole Base 9/8 mtrs Pole Supports with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 240.45 | 240.45 | 4.0 | False | None | None | False | None | False | 961.8 | 0 |
4033865 | 156493 | None | code208 | Providing Coping for Poles with CC 1:2:4 a) 150 mm around poles for a height of 300 mm for RCC PSC PCC Poles/ I - Beam/ Rail Steel sections with all lead and lift etc complete as per specifications and as directed by engineer in charge. | No | 466.2 | 466.2 | 4.0 | False | None | None | False | None | False | 1864.8 | 0 |
4033866 | 156493 | None | code209 | B) Pole concreting with CC 1:2:4 (without coping) a) 9mtrs support (650x500x1700mm) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 2694.3 | 2694.3 | 6.0 | False | None | None | False | None | False | 16165.8 | 0 |
4033867 | 156493 | None | code210 | e) Guy concreting as above but with cement concrete of concrete mix M5 with OPC cement at 160 Kgs with all lead and lift etc complete as per specifications and as directed by engineer in charge. | No | 865.2 | 865.2 | 2.0 | False | None | None | False | None | False | 1730.4 | 0 |
4033868 | 156493 | None | code211 | Supplying fixing and wiring earth electrode for grounding of lifts transformers DG sets etc using 40mm dia 29mm thick 25 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber The connection from the electrode is to be established through GI strip using GI bolts and nuts with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 4468.8 | 4468.8 | 12.0 | False | None | None | False | None | False | 53625.6 | 0 |
4033869 | 156493 | None | code212 | HT Cable GROUP A: Supplying and laying of high tension 11KV cable Dry Curing & Dry Cooling with true triple extrusion simultaneously through a single common head 3 core under ground XLPE (E) cable having stranded comapact circular aluminium conductor screened insulated insulation screened with extruded semiconduting compound in combination with copper tape core laid up inner sheathed of PVC tape GI flat strip armoured and overall PVC sheathed wisth specified IS 7098/11/85 with latest amendments & confirming to the GTP of Group A 3Cx95sqmms with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 934.14 | 934.14 | 150.0 | False | None | None | False | None | False | 140121.0 | 0 |
4033870 | 156493 | None | code213 | Supplying and making 11KV (E) Extruded "X"linked for tubing & moulded & cross linked components using Heat shrink Stress control tube having High Permitivity XLPE Terminations OUTDOOR 3Cx95/120Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Kit | 2790.9 | 2790.9 | 6.0 | False | None | None | False | None | False | 16745.4 | 0 |
4033871 | 156493 | None | code214 | Supplying and making 11KV (E) Extruded "X"linked for tubing & moulded & cross linked components using Heat shrink Stress control tube having High Permitivity XLPE Terminations INDOOR 3Cx95/120Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Kit | 2790.9 | 2790.9 | 6.0 | False | None | None | False | None | False | 16745.4 | 0 |
4033872 | 156493 | None | code215 | Supplying of 11 KV LT UG cable having aluminum conductor PVC insulated extruded inner sheathed galvanized steel strip (except 2CX10Sqmm wire armoured) confirming to IS-3975:1990 (No of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP of GROUP-A 35 core 120 sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 479.72 | 479.72 | 240.0 | False | None | None | False | None | False | 115132.8 | 0 |
4033873 | 156493 | None | code216 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / sTonneeware pipe / on wall / on pole as required in existing trench/dust 95sqmm to 150sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 64.39 | 64.39 | 240.0 | False | None | None | False | None | False | 15453.6 | 0 |
4033874 | 156493 | None | code217 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 120 sqmm Long Barrel with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 147.0 | 147.0 | 20.0 | False | None | None | False | None | False | 2940.0 | 0 |
4033875 | 156493 | None | code218 | Supply of GI pipe 100 mm (Nominal bore), medium class (including accessories) 100mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 1417.5 | 1417.5 | 100.0 | False | None | None | False | None | False | 141750.0 | 0 |
4033876 | 156493 | None | code219 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 108.15 | 108.15 | 95.0 | False | None | None | False | None | False | 10274.25 | 0 |
4033877 | 156493 | None | code220 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete(As per Civil SR KSRB I-2 P-7) In soil (hard) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 168.0 | 168.0 | 95.0 | False | None | None | False | None | False | 15960.0 | 0 |
4033878 | 156493 | None | code221 | Supplying erection Testing and Commissioning of …KVA Aluminum Wound Distribution Transformer tap switch Butchholtz relay winding Temperature indicator oil temperature indicator marshalling box with wiring magnetic oil level indicator with +5Percentage to -10Percentage steps of 2.5Percentage with HT and LT cable end boxes including all standard accessories as per latest IS Standard Technical Specification - 4star rated 100 KVA with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 222190.5 | 222190.5 | 1.0 | False | None | None | False | None | False | 222190.5 | 0 |
4033879 | 156493 | None | code222 | LT Distribution Box for 63/100 KVA Transformer with 1No 160Amps 25kA 4Pole MCCB suitable capacity aluminum bus bar mounted in 16SWG powder coated MSBox suitable to mount at Transformer Centre as per BESCOM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Set | 23820.3 | 23820.3 | 1.0 | False | None | None | False | None | False | 23820.3 | 0 |
4033880 | 156493 | None | code223 | Supplying and fixing of Alkathine Tube Of 25mm dia as per standard technical specification with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 542.85 | 542.85 | 30.0 | False | None | None | False | None | False | 16285.5 | 0 |
4033881 | 156493 | None | code224 | Supplying and fixing of Spiral Earth Electrodes as per standard technical specification as per BESCOM with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 250.95 | 250.95 | 4.0 | False | None | None | False | None | False | 1003.8 | 0 |
4033882 | 156493 | None | code225 | Supplying and running of GI/Copper strips for grounding connections using necessary fixing materials as required GI strip 25x3mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 86.1 | 86.1 | 85.0 | False | None | None | False | None | False | 7318.5 | 0 |
4033883 | 156493 | None | code226 | Supplying and running of GI/Copper strips for grounding connections using necessary fixing materials as requiredCOPPER strip 25x3mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 598.5 | 598.5 | 20.0 | False | None | None | False | None | False | 11970.0 | 0 |
4033884 | 156493 | None | code227 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers 8SWG with all lead and lift etc complete as per specifications and as directed by engineer in charge. SR-2023-24 | Mtr | 7.88 | 7.88 | 60.0 | False | None | None | False | None | False | 472.8 | 0 |
4033885 | 156493 | None | code228 | Supplying and spreading of jelly of 25 mm down size with 100 mm thick in the area of metering cubicle and transformer sub station of area 10mtrs X 8 mtrs with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 1861.65 | 1861.65 | 8.0 | False | None | None | False | None | False | 14893.2 | 0 |
4033886 | 156493 | None | code229 | Construction of platform with size sTone cement concert for erection of 500 kVA Transformer / Metering cubicle / Heavy Equipment Construction o f platform (15x15x12) mtr in size sTonnee for erection of transformers / Heavy equipment including all materials labour Excavation of (15x15x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers well compacted curing etc complete providing and construction of sTonnee masonary 09m below ground level and 12m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to sTonnee masonary in cement morter 1:3 after racking joint & nisely lining curing etc plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc curing at every stages completely with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Nos | 31879.05 | 31879.05 | 2.0 | False | None | None | False | None | False | 63758.1 | 0 |
4033887 | 156493 | None | code230 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts and nuts the free ends shall be welded to the pole and the block pipe at top and bottom as required including cost of all materials labour lead and lifts cutting bending wherever necessary wastage and lapping etc complete as per direction of the Engineer - in - charge of work including two coats of approved quality paint over one coat of shop paint(Size-10m Length x 8m width x 26m height) with all lead and lift etc complete as per specifications and direction of engineer in charge. | Sqm | 1036.35 | 1036.35 | 93.6 | False | None | None | False | None | False | 97002.36 | 0 |
4033888 | 156493 | None | code231 | 11kV HT Metering Panel 3 CT 3 PT for 3 Phase 4 Wire Metering With Transparent Cover TTB with 30x8mm Cu Bus bars (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated Without Meter) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
4033889 | 156493 | None | code232 | Class ETV Meter with ABT Feature & DLMS Protocal with ToD for above with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 19237.05 | 19237.05 | 1.0 | False | None | None | False | None | False | 19237.05 | 0 |
4033890 | 156493 | None | code233 | KSRB 2-22 : Earthwork excavation for foundation of buildings water supply sanitary lines and electrical conduits either in pits or in trenches 15m and above in width in hard soil not exceeding 15 m in depth including dressing the bottom and sides of pits and trenches stacking the excavated soil clear from edges of excavation with lead upto 50 m after breaking of clods complete as per specifications with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 254.1 | 254.1 | 16.01 | False | None | None | False | None | False | 4068.141 | 0 |
4033891 | 156493 | None | code234 | KSRB 25 : Earthwork excavation (in soil deposits) and filling sides of foundation upto plinth in layers not exceeding 20cms in depth compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications and as directed by engineer in charge. | Cum | 254.1 | 254.1 | 61.23 | False | None | None | False | None | False | 15558.543 | 0 |
4033892 | 156493 | None | code235 | KSRB 4-13 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement at 180kgs with 40mm and down size graded granite metal coarse aggregates at085cum and fine aggregates at 057cum machine mixed machine mixed concrete laid in layers not exceeding 15 cms thick well compacted in foundation including cost of all materials labour HOM of machinery curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 5947.2 | 5947.2 | 3.76 | False | None | None | False | None | False | 22361.472 | 0 |
4033893 | 156493 | None | code236 | KSRB 4-16 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement at 240kgs with 20mm and down size graded granite metal coarse aggregates at 069 cum and fine aggregtes at 0459cum machine mixed concrete laid in layers not exceeding 15 cms thick well compacted in foundation plinth and cills ncluding cost of all materials labour HOM of machinery curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 6555.15 | 6555.15 | 3.56 | False | None | None | False | None | False | 23336.334 | 0 |
4033894 | 156493 | None | code237 | KSRB 54-3 : Providing and constructing granite / trap / basalt size sTonnee masonry in superstructure with cement mortar 1:6 edges of sTonnees chistle dressed in courses not less than 15 cms high bond sTonnees at two m apart in each course including cost of materials labour scaffolding curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 6708.45 | 6708.45 | 3.85 | False | None | None | False | None | False | 25827.5325 | 0 |
4033895 | 156493 | None | code238 | KSRB15-39 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6 to brick masonry including rounding off corners wherever required smooth rendering : Providing and removing scaffolding including cost of materials labour curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 349.65 | 349.65 | 85.0 | False | None | None | False | None | False | 29720.25 | 0 |
4033896 | 156493 | None | code239 | KSRB 15-161 : Providing and finishing external walls in two coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials labour complete as per specifications - with primer with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 93.45 | 93.45 | 96.25 | False | None | None | False | None | False | 8994.5625 | 0 |
4033897 | 156493 | None | code240 | KSRB 6-23 : Providing and constructing burnt brick masonry with approved quality of non-modular bricks of standard size of class designation 50NewTonne per sqmm (table moulded) with cement mortar 1:6 for basement and superstructu/re including cost of materials labour charges scaffolding curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 8631.0 | 8631.0 | 4.5 | False | None | None | False | None | False | 38839.5 | 0 |
4033898 | 156493 | None | code241 | KSRB 15-182 : Providing and applying enamel metal paint two coats ( excluding priming coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil grease dirt and other foreign matter including cost of materials labour with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Sqm | 120.75 | 120.75 | 100.0 | False | None | None | False | None | False | 12075.0 | 0 |
4033899 | 156493 | None | code242 | KSRB 79 : Providing and fixing MSgrill work for windows and ventilators weighing 21kg/sqm using MS flats or MS square rods or combination of MS flats and square rods as per approved design drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer cost of materials fixtures labour and HOM of machinery with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Kg | 176.4 | 176.4 | 609.0 | False | None | None | False | None | False | 107427.6 | 0 |
4033900 | 156493 | None | code243 | Diesel Generator set : Supplying erection testing and commissioning 63 KVA Diesel Generating Set on existing CC platform Comprising of Diesel Engine Developing …BHP at 1500RPM confirming to BS 5514 The engine should be trubocharged Air/water cooled with 10Percentage over load for 1 hour in every 12 hours of operation coupled to suitable capacity alternator rated at 415V08 PF(lag) 50 Hz 3 Phase 4 wire system confirming to Sceenprotected revolving field Mounted on suitable Channel Iron Base Frame Complete wisth suitable capacity Fuel Tank required number of Batteries of 12/24V as per requirement Accoustic enclosure as per CPCB Approved Norms 62.5 KVA / 50 KW with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 673124.55 | 673124.55 | 1.0 | False | None | None | False | None | False | 673124.55 | 0 |
4033901 | 156493 | None | code244 | Supply Erection testing and commissioning of AMF panel suitabe for…KVA DG set The panel is of cubical type base/floor mounting control panel wisth hinged door undrilled bottom gland plate of suitable capacity aluminium Bus Bar with accommodation for 2 pole contactor and 4 pole MCCB for alternator with thermal O/L relay 3pole contactor and 4 pole MCCB for mains HRC fuse/MCB for short circuit protection Microprocessar based AMF module with supply failure timer Restoration timer 3 impulse automatic engine start/stop logic Mains/genrator voltage capacity bypass switch and frequency sensing PCC 1301 controller wisth water tempratureLube oil pressure/eingine speed Voltage amphere/Frequency/KVA Running-hour counte No of start Fault indication over/Under speed Fails to starts low oil preasure High engine temprature Under/over voltage over current Earth fault relay with indications for Mains on Load on Mains Battery charger on Push butTonnes AMF module by pass Mode Battary charger unit with inbuilt AutoMannual and Flot/Boost facility upto 62.5 KVA with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 81656.4 | 81656.4 | 1.0 | False | None | None | False | None | False | 81656.4 | 0 |
4033902 | 156493 | None | code245 | Supplying fixing wiring earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth The connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI specification 733 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the pipe shall have 16 through holes of 122 mm dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3685.5 | 3685.5 | 3.0 | False | None | None | False | None | False | 11056.5 | 0 |
4033903 | 156493 | None | code246 | Supplying and running of GI strips for grounding connections using necessary fixing materials as required 25x6mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 134.4 | 134.4 | 50.0 | False | None | None | False | None | False | 6720.0 | 0 |
4033904 | 156493 | None | code247 | Supplying and running of Copper strips for grounding connections using necessary fixing materials as required 600x600x3mm plate with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 7792.05 | 7792.05 | 3.0 | False | None | None | False | None | False | 23376.15 | 0 |
4033905 | 156493 | None | code248 | Supplying of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 3.5c X 95Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 934.15 | 934.15 | 60.0 | False | None | None | False | None | False | 56049.0 | 0 |
4033906 | 156493 | None | code249 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm | Mtr | 64.39 | 64.39 | 60.0 | False | None | None | False | None | False | 3863.4 | 0 |
4033907 | 156493 | None | code250 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating In soil (Hard) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 408.45 | 408.45 | 55.0 | False | None | None | False | None | False | 22464.75 | 0 |
4033908 | 156493 | None | code251 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm alround the cable with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 17.43 | 17.43 | 55.0 | False | None | None | False | None | False | 958.65 | 0 |
4033909 | 156493 | None | code252 | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting sockets /Couplings /Tees /Bends /End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables 120mm OD / 103mm ID with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 127.05 | 127.05 | 40.0 | False | None | None | False | None | False | 5082.0 | 0 |
4033910 | 156493 | None | code253 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 240sqmm long barrel with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 372.75 | 372.75 | 8.0 | False | None | None | False | None | False | 2982.0 | 0 |
4033911 | 156493 | None | code254 | KSRB 2-22 : Earthwork excavation for foundation of buildings water supply sanitary lines and electrical conduits either in pits or in trenches 15m and above in width in hard soil not exceeding 15 m in depth including dressing the bottom and sides of pits and trenches stacking the excavated soil clear from edges of excavation with lead upto 50 m after breaking of clods with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 254.1 | 254.1 | 4.5 | False | None | None | False | None | False | 1143.45 | 0 |
4033912 | 156493 | None | code255 | KSRB 4-13 :Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement at 180 kgs with 40mm and down size graded granite metal coarse aggregates at 085 cum and fine aggregates at 057cum machine mixed concrete laid in layers not exceeding 15 cms thick well compacted in foundation and plinth including cost of all materials labour HOM of machinery curing with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 5947.2 | 5947.2 | 1.2 | False | None | None | False | None | False | 7136.64 | 0 |
4033913 | 156493 | None | code256 | KSRB 422: Providing and laying in position reinforced cement concrete of design mix M 20 with OPC cement at 320 kgs with 20mm and down size graded granite metal coarse aggregateat 0878 cum and fine aggregates at 0459 cum with superplastisiser at 3lts confirming to IS9103-1999 Reaffirmed -2008 machine mixed concrete laid in layers not exceeding 15 cms thick vibrated for all works in foundation for footingspedestalsretaining walls return walls walls ( any thickness) including attached plasters columnspillerspostsstruts buttresses string or lacing courses parapets coping bed blocks anchor blocks & plinths etcincluding cost of all materials labour HOM of machinery curing complete as per specifications (Excluding cost of steel fabrication & plastering charges) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Cum | 6961.5 | 6961.5 | 5.4 | False | None | None | False | None | False | 37592.1 | 0 |
4033914 | 156493 | None | code257 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts and nuts the free ends shall be welded to the pole and the block pipe at top and bottom as required including cost of all materials labour lead and lifts cutting bending wherever necessary wastage and lapping etc complete as directed by Engineer - in - charge of work including two coats of approved quality paint over one coat of shop paint(Size-10m Length x 8m width x 26m height) | Sqm | 883.05 | 883.05 | 93.6 | False | None | None | False | None | False | 82653.48 | 0 |
4033915 | 156493 | None | code258 | 3HP Monoblock Submersible Pump: Supply and Delivery of Monoblock Submersible pump sets suitable for borewells of 15mm dia with specified duty conditions as details below and satisfying performance charcteristics for pump and motor specified in BIS with ISI mark with a minimum efficiency of 42Percentage pump confirm to IS 8034/2002 and motor confirming to IS 9283/1995 inclusive of all taxes with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 47250.0 | 47250.0 | 1.0 | False | None | None | False | None | False | 47250.0 | 0 |
4033916 | 156493 | None | code259 | Supply of Panel board unit consisits of ammeter voltmeter push butTonne switch single phase preventor indicator fuse cutouts over load relay and danger board indicator fuse cutouts over load relay and danger board indicators fixed in a cubicle type control panel board of size 350 x 380x 150mm made out of 16mm sheet metal to operate 3 phase/ 4ph 50 hz 400/440 volts AC supply including of all taxes Out door type upto 6HP with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 15750.0 | 15750.0 | 1.0 | False | None | None | False | None | False | 15750.0 | 0 |
4033917 | 156493 | None | code260 | Errection of panel board and meter board with all necessary materials and labour charges with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 10500.0 | 10500.0 | 1.0 | False | None | None | False | None | False | 10500.0 | 0 |
4033918 | 156493 | None | code261 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia mm thick confirming to IS 2509 woth suitable size bends metal/PVC junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 81.9 | 81.9 | 110.0 | False | None | None | False | None | False | 9009.0 | 0 |
4033919 | 156493 | None | code262 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 3/5 Way with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
4033920 | 156493 | None | code263 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP-a 25 Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 44.1 | 44.1 | 110.0 | False | None | None | False | None | False | 4851.0 | 0 |
4033921 | 156493 | None | code264 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP-a 4 Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 66.15 | 66.15 | 110.0 | False | None | None | False | None | False | 7276.5 | 0 |
4033922 | 156493 | None | code265 | Supply and fixing of bakelite DP/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per 1293 and IS 3854 Group A 16Amps Flush type Universal socket with all lead and lift etc complete as per specifications and as directed by engineer in charge.32A | Each | 342.3 | 342.3 | 1.0 | False | None | None | False | None | False | 342.3 | 0 |
4033923 | 156493 | None | code266 | Supply and fixing of bakelite DP/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per 1293 and IS 3854 Group A 32Amps Flush/projected type DP switch with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 243.6 | 243.6 | 1.0 | False | None | None | False | None | False | 243.6 | 0 |
4033924 | 156493 | None | code267 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 4786.95 | 4786.95 | 1.0 | False | None | None | False | None | False | 4786.95 | 0 |
4033925 | 156493 | None | code268 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low conductor resistance confirming to table 3class 5of IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts with specified IS-694:1990 & confirming to the attached GTP of GROUP-A 3C x 2.5Sqmm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 122.85 | 122.85 | 120.0 | False | None | None | False | None | False | 14742.0 | 0 |
4033926 | 156493 | None | code269 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating in soil (hard) with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 408.45 | 408.45 | 110.0 | False | None | None | False | None | False | 44929.5 | 0 |
4033927 | 156493 | None | code270 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm alround the cable with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 17.43 | 17.43 | 110.0 | False | None | None | False | None | False | 1917.3 | 0 |
4033928 | 156493 | None | code271 | Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5-32Amps TPN with all lead and lift etc complete as per specifications and direction of engineer in charge. | Each | 1802.85 | 1802.85 | 1.0 | False | None | None | False | None | False | 1802.85 | 0 |
4033929 | 156493 | None | code272 | Supplying and fixing angle iron frame work fabricated out of MS angle iron and MS flat … with bolts washers etc and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 414.75 | 414.75 | 10.0 | False | None | None | False | None | False | 4147.5 | 0 |
4033930 | 156493 | None | code273 | Fixing a shunt capacitor of … KVAR capacity with necessary clamps bolts and nuts on existing wooden or metal board including banking of more than one capacitor upto 5KVAR with all lead and lift etc complete as per specifications and as directed by engineer in charge.PWD ele | Each | 161.7 | 161.7 | 1.0 | False | None | None | False | None | False | 161.7 | 0 |
4033931 | 156493 | None | code274 | Supplying fixing and wiring heavy duty low voltage capacitors conforming to IS 2834 3 phase 400/440 volts grade for power factor improvements of rotating machinery with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Kvar | 504.0 | 504.0 | 3.0 | False | None | None | False | None | False | 1512.0 | 0 |
4033932 | 156493 | None | code275 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 20"x20"25" with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 342.44 | 342.44 | 2.0 | False | None | None | False | None | False | 684.88 | 0 |
4033933 | 156493 | None | code276 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts bolts and washers 32Amps with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 253.05 | 253.05 | 3.0 | False | None | None | False | None | False | 759.15 | 0 |
4033934 | 156493 | None | code277 | Supplying fixing wiring earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 290mm thick GI pipe 25 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth The connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI specification 733 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the pipe shall have 16 through holes of 122 mm dia with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Each | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 |
4033935 | 156493 | None | code278 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers 8SWG COPPER with all lead and lift etc complete as per specifications and as directed by engineer in charge. | Mtr | 78.79 | 78.79 | 20.0 | False | None | None | False | None | False | 1575.8 | 0 |