tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1726039107000 | 0 | None | None | Buildings | BUILDING | 4209559.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954896 | 153247 | None | code01 | Earth work in surface excavation by mechanical means for lowering & levelingthe ground for all works other than foundation in all kinds of soils & upto depthnot exceeding 300mm as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting & stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth complete as per direction of the Engineer-in-charge of the work | Sqm | 99.75 | 99.75 | 234.9 | False | None | None | False | None | False | 23431.275 | 0 | 3954897 | 153247 | None | code02 | Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m complete as per direction of the Engineer-in-charge of the work | Cum | 107.1 | 107.1 | 105.16 | False | None | None | False | None | False | 11262.636 | 0 | 3954898 | 153247 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6288.45 | 6288.45 | 11.94 | False | None | None | False | None | False | 75084.093 | 0 | 3954899 | 153247 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6652.8 | 6652.8 | 18.46 | False | None | None | False | None | False | 122810.688 | 0 | 3954900 | 153247 | None | code05 | Formwork & Centring Charges @ 8% complete as per direction of the Engineer-in-charge of the work | Cum | 532.22 | 532.22 | 18.46 | False | None | None | False | None | False | 9824.7812 | 0 | 3954901 | 153247 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6652.8 | 6652.8 | 11.18 | False | None | None | False | None | False | 74378.304 | 0 | 3954902 | 153247 | None | code07 | Formwork & Centring Charges @ 70% complete as per direction of the Engineer-in-charge of the work | Cum | 4656.96 | 4656.96 | 1.92 | False | None | None | False | None | False | 8941.3632 | 0 | 3954903 | 153247 | None | code08 | Formwork & Centring Charges @ 50% complete as per direction of the Engineer-in-charge of the work | Cum | 3326.4 | 3326.4 | 9.26 | False | None | None | False | None | False | 30802.464 | 0 | 3954904 | 153247 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 7185.15 | 7185.15 | 27.28 | False | None | None | False | None | False | 196010.892 | 0 | 3954905 | 153247 | None | code10 | Formwork & Centring Charges @ 70% complete as per direction of the Engineer-in-charge of the work | Cum | 5029.6 | 5029.6 | 10.64 | False | None | None | False | None | False | 53514.944 | 0 | 3954906 | 153247 | None | code11 | Formwork & Centring Charges @ 60% complete as per direction of the Engineer-in-charge of the work | Cum | 4311.09 | 4311.09 | 16.64 | False | None | None | False | None | False | 71736.5376 | 0 | 3954907 | 153247 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 7185.15 | 7185.15 | 1.15 | False | None | None | False | None | False | 8262.9225 | 0 | 3954908 | 153247 | None | code13 | Formwork & Centring Charges @ 45% complete as per direction of the Engineer-in-charge of the work | Cum | 3233.31 | 3233.31 | 1.15 | False | None | None | False | None | False | 3718.3065 | 0 | 3954909 | 153247 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 7185.15 | 7185.15 | 23.97 | False | None | None | False | None | False | 172228.0455 | 0 | 3954910 | 153247 | None | code15 | Formwork & Centring Charges @ 50% complete as per direction of the Engineer-in-charge of the work | Cum | 3592.57 | 3592.57 | 23.97 | False | None | None | False | None | False | 86113.9029 | 0 | 3954911 | 153247 | None | code16 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete as per direction of the Engineer-in-charge of the work | Cum | 6948.9 | 6948.9 | 12.59 | False | None | None | False | None | False | 87486.651 | 0 | 3954912 | 153247 | None | code17 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) complete as per direction of the Engineer-in-charge of the work | Cum | 6515.25 | 6515.25 | 12.28 | False | None | None | False | None | False | 80007.27 | 0 | 3954913 | 153247 | None | code18 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.complete as per direction of the Engineer-in-charge of the work | Cum | 8367.45 | 8367.45 | 61.55 | False | None | None | False | None | False | 515016.5475 | 0 | 3954914 | 153247 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. complete as per direction of the Engineer-in-charge of the work | Tonne | 93929.85 | 93929.85 | 7.4 | False | None | None | False | None | False | 695080.89 | 0 | 3954915 | 153247 | None | code20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete as per direction of the Engineer-in-charge of the work | Cum | 279.3 | 279.3 | 156.66 | False | None | None | False | None | False | 43755.138 | 0 | 3954916 | 153247 | None | code21 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) complete as per direction of the Engineer-in-charge of the work | Cum | 6527.85 | 6527.85 | 25.62 | False | None | None | False | None | False | 167243.517 | 0 | 3954917 | 153247 | None | code22 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 292.95 | 292.95 | 523.96 | False | None | None | False | None | False | 153494.082 | 0 | 3954918 | 153247 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 504.25 | False | None | None | False | None | False | 196430.5875 | 0 | 3954919 | 153247 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 523.96 | False | None | None | False | None | False | 55015.8 | 0 | 3954920 | 153247 | None | code25 | Providing and laying Polished Glazed Vitrifed tiles in floor with different sizes (thickness to be specifed by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modifed quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x1200 mm | Sqm | 1392.3 | 1392.3 | 172.63 | False | None | None | False | None | False | 240352.749 | 0 | 3954921 | 153247 | None | code26 | Providing and fxing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/m2 including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge. | m | 142.8 | 142.8 | 103.58 | False | None | None | False | None | False | 14791.224 | 0 | 3954922 | 153247 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2994.6 | 2994.6 | 44.1 | False | None | None | False | None | False | 132061.86 | 0 | 3954923 | 153247 | None | code28 | Providing and fxing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 176.4 | 176.4 | 547.2 | False | None | None | False | None | False | 96526.08 | 0 | 3954924 | 153247 | None | code29 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. | Sqm | 7070.7 | 7070.7 | 28.8 | False | None | None | False | None | False | 203636.16 | 0 | 3954925 | 153247 | None | code30 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged | Kg | 593.25 | 593.25 | 309.6 | False | None | None | False | None | False | 183670.2 | 0 | 3954926 | 153247 | None | code31 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. --do-- sal wood frames. | Cum | 103755.75 | 103755.75 | 0.432 | False | None | None | False | None | False | 44822.484 | 0 | 3954927 | 153247 | None | code32 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifcations. | Nos | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3954928 | 153247 | None | code33 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures) | Sqm | 7241.85 | 7241.85 | 11.52 | False | None | None | False | None | False | 83426.112 | 0 | 3954929 | 153247 | None | code34 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 511.96 | False | None | None | False | None | False | 73645.446 | 0 | 3954930 | 153247 | None | code35 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 504.25 | False | None | None | False | None | False | 149837.8875 | 0 | 3954931 | 153247 | None | code36 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 25.92 | False | None | None | False | None | False | 3755.808 | 0 | 3954932 | 153247 | None | code36 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge complete as per specifcations. complete as per direction of the Engineer-in-charge of the work | Kg | 154.35 | 154.35 | 151.2 | False | None | None | False | None | False | 23337.72 | 0 | 3954933 | 153247 | None | code36 | Providing and fxing precoated galvanised iron profle sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm(+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard flm of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12m or as desired by Engineer-in-charge. The sheet shall be fxed usingself drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. complete as per specifcations. complete as per direction of the Engineer-in-charge of the work | Sqm | 596.4 | 596.4 | 23.1 | False | None | None | False | None | False | 13776.84 | 0 |
| 1726039107000 | 0 | None | None | Buildings | Borewell and pumping machinery | 280684.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954934 | 153248 | None | code01 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of
capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete I) 0.00mtrs. to 50.00 mtrs depth complete as per direction of the Engineer-in-charge of the work | Mtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3954935 | 153248 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of
capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete II) Above 50.00mtrs. and upto 100.00 mtrs Depth complete as per direction of the Engineer-in-charge of the work | Mtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3954936 | 153248 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of
capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete III) Above 100.00mtrs. and upto 150.00 mtrs Depth complete as per direction of the Engineer-in-charge of the work | Mtr | 517.65 | 517.65 | 50.0 | False | None | None | False | None | False | 25882.5 | 0 | 3954937 | 153248 | None | code04 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of
capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete IV) Above 150.00mtrs. and upto 200.00 mtrs Depth complete as per direction of the Engineer-in-charge of the work | Mtr | 600.6 | 600.6 | 30.0 | False | None | None | False | None | False | 18018.0 | 0 | 3954938 | 153248 | None | code05 | Providing and installing at site of work P.V.C. pipes including cost of
pipes and specials and labour, including lowering into trenches, laying
true to line, level and perfect linking at joints leak proof including
jointing of approved type with all labour charges and all lift charges,
handling charges including encasing the pipe around to a depth not less
than 15 cms with gravel or selected earth available from the excavation
etc. complete.. complete as per direction of the Engineer-in-charge of the work | Mtr | 1015.35 | 1015.35 | 10.0 | False | None | None | False | None | False | 10153.5 | 0 | 3954939 | 153248 | None | code06 | Providing and laying at site of work MS casing caps as per IS 1239 (part-
II) 1982 with all latest amendments if any for any dia. The thickness of
plate used for covering one end shall be 3mm (minimum). The dimensionsof caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineerin chargecomplete as per direction of the Engineer-in-charge of the work | Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 | 3954940 | 153248 | None | code07 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.complete as per direction of the Engineer-in-charge of the work | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3954941 | 153248 | None | code08 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00complete. complete as per direction of the Engineer-in-charge of the work | Each | 33743.85 | 33743.85 | 1.0 | False | None | None | False | None | False | 33743.85 | 0 | 3954942 | 153248 | None | code09 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. complete as per direction of the Engineer-in-charge of the work | m | 141.75 | 141.75 | 190.0 | False | None | None | False | None | False | 26932.5 | 0 | 3954943 | 153248 | None | code10 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. complete as per direction of the Engineer-in-charge of the work | Each | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 | 3954944 | 153248 | None | code11 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.complete as per direction of the Engineer-in-charge of the work | Kvar | 577.5 | 577.5 | 3.0 | False | None | None | False | None | False | 1732.5 | 0 | 3954945 | 153248 | None | code12 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentscomplete as per direction of the Engineer-in-charge of the work | m | 577.5 | 577.5 | 160.0 | False | None | None | False | None | False | 92400.0 | 0 | 3954946 | 153248 | None | code13 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. complete as per direction of the Engineer-in-charge of the work | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3954947 | 153248 | None | code14 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. complete as per direction of the Engineer-in-charge of the work | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3954948 | 153248 | None | code15 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia complete as per direction of the Engineer-in-charge of the work | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |
| 1726039107000 | 0 | None | None | Buildings | Electrification | 90034.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954949 | 153249 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mm complete as per direction of the Engineer-in-charge of the work | Mtr | 35.0 | 35.0 | 80.0 | False | None | None | False | None | False | 2800.0 | 0 | 3954950 | 153249 | None | code02 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 | 3954951 | 153249 | None | code03 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 394.0 | 394.0 | 12.0 | False | None | None | False | None | False | 4728.0 | 0 | 3954952 | 153249 | None | code04 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 570.0 | 570.0 | 10.0 | False | None | None | False | None | False | 5700.0 | 0 | 3954953 | 153249 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694: 1990 & confirming to GTP of GROUP A. 1.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 26.0 | 26.0 | 320.0 | False | None | None | False | None | False | 8320.0 | 0 | 3954954 | 153249 | None | code06 | 2.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 42.0 | 42.0 | 150.0 | False | None | None | False | None | False | 6300.0 | 0 | 3954955 | 153249 | None | code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way complete as per direction of the Engineer-in-charge of the work | Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 | 3954956 | 153249 | None | code08 | 10-12Way complete as per direction of the Engineer-in-charge of the work | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 3954957 | 153249 | None | code09 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module complete as per direction of the Engineer-in-charge of the work | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 | 3954958 | 153249 | None | code10 | 10-12 Module complete as per direction of the Engineer-in-charge of the work | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 3954959 | 153249 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A. 6 Amps one way Switch complete as per direction of the Engineer-in-charge of the work | Each | 102.0 | 102.0 | 24.0 | False | None | None | False | None | False | 2448.0 | 0 | 3954960 | 153249 | None | code12 | 6Amps 3 way Socket complete as per direction of the Engineer-in-charge of the work | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 3954961 | 153249 | None | code13 | Stepped fan Regulator complete as per direction of the Engineer-in-charge of the work | Each | 357.0 | 357.0 | 6.0 | False | None | None | False | None | False | 2142.0 | 0 | 3954962 | 153249 | None | code14 | 32 Amps Dp switch complete as per direction of the Engineer-in-charge of the work | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 3954963 | 153249 | None | code15 | Supplying & Fixing of 70-150 W lamp holder 2 Pin complete as per direction of the Engineer-in-charge of the work | Each | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | 3954964 | 153249 | None | code16 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps complete as per direction of the Engineer-in-charge of the work | Each | 157.0 | 157.0 | 2.0 | False | None | None | False | None | False | 314.0 | 0 | 3954965 | 153249 | None | code17 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT. complete as per direction of the Engineer-in-charge of the work | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 | 3954966 | 153249 | None | code18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP complete as per direction of the Engineer-in-charge of the work | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 3954967 | 153249 | None | code19 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with
54W power consumption with low 3mg Mercury content less
phosphor coating Operating voltage range from 180V to 265V,
50Hz AC power Supply. complete as per direction of the Engineer-in-charge of the work | Each | 520.0 | 520.0 | 15.0 | False | None | None | False | None | False | 7800.0 | 0 | 3954968 | 153249 | None | code20 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48 Sweep 5 Star (1200 mm) complete as per direction of the Engineer-in-charge of the work | Each | 4303.0 | 4303.0 | 6.0 | False | None | None | False | None | False | 25818.0 | 0 | 3954969 | 153249 | None | code21 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (on wall/ceiling/rafter/girders complete as per direction of the Engineer-in-charge of the work | Each | 122.0 | 122.0 | 30.0 | False | None | None | False | None | False | 3660.0 | 0 | 3954970 | 153249 | None | code22 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 10sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 167.0 | 167.0 | 30.0 | False | None | None | False | None | False | 5010.0 | 0 | 3954971 | 153249 | None | code23 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box complete as per direction of the Engineer-in-charge of the work | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 | 3954972 | 153249 | None | code24 | LT AC Single Phase 2 Wire, 5-30 Amps Smart Energy
Meter, Class 1.0 Accuracy with RF Communication
Module complete as per direction of the Engineer-in-charge of the work | Each | 2461.0 | 2461.0 | 1.0 | False | None | None | False | None | False | 2461.0 | 0 |
| 1726039107000 | 0 | None | None | Buildings | Repair work | 681120.81 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954973 | 153250 | None | code01 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mmthick on 10mm thick cement plaster 1:3 and jointed with white cementslurry over existing rough plaster surface using glazed tiles of approvedmake and size including cost of materials, labour, complete as perspecifications complete as per direction of the Engineer-in-charge of the work | Sqm | 1461.6 | 1461.6 | 146.61 | False | None | None | False | None | False | 214285.176 | 0 | 3954974 | 153250 | None | code02 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge complete as per direction of the Engineer-in-charge of the work | Sqm | 1231.65 | 1231.65 | 15.08 | False | None | None | False | None | False | 18573.282 | 0 | 3954975 | 153250 | None | code03 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc complete as per direction of the Engineer-in-charge of the work | m | 500.85 | 500.85 | 65.0 | False | None | None | False | None | False | 32555.25 | 0 | 3954976 | 153250 | None | code04 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc complete as per direction of the Engineer-in-charge of the work | m | 584.85 | 584.85 | 25.0 | False | None | None | False | None | False | 14621.25 | 0 | 3954977 | 153250 | None | code05 | Providing flooring with 25mm thick polished Cuddapah slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of rooflaid to line and level and jointed with cement slurry mixed with pigmentto match the shade of the slab , including cost of materials, labour, curing,polishing complete as per specifications. complete as per direction of the Engineer-in-charge of the work | Sqm | 825.3 | 825.3 | 13.5 | False | None | None | False | None | False | 11141.55 | 0 | 3954978 | 153250 | None | code06 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required complete as per direction of the Engineer-in-charge of the work | Each | 4676.7 | 4676.7 | 6.0 | False | None | None | False | None | False | 28060.2 | 0 | 3954979 | 153250 | None | code07 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizesrespectively. complete as per direction of the Engineer-in-charge of the work | Each | 1211.7 | 1211.7 | 6.0 | False | None | None | False | None | False | 7270.2 | 0 | 3954980 | 153250 | None | code08 | Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primerincluding cost of materials ,labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge. complete as per direction of the Engineer-in-charge of the work | Sqm | 8689.8 | 8689.8 | 17.79 | False | None | None | False | None | False | 154591.542 | 0 | 3954981 | 153250 | None | code09 | Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. complete as per direction of the Engineer-in-charge of the work | Sqm | 1023.75 | 1023.75 | 17.64 | False | None | None | False | None | False | 18058.95 | 0 | 3954982 | 153250 | None | code10 | Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to steel windows by welding complete as per direction of the Engineer-in-charge of the work | Kg | 176.4 | 176.4 | 402.67 | False | None | None | False | None | False | 71030.988 | 0 | 3954983 | 153250 | None | code11 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications complete as per direction of the Engineer-in-charge of the work | Sqm | 113.4 | 113.4 | 978.24 | False | None | None | False | None | False | 110932.416 | 0 |
|
|
---|