createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726928231720
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd45000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-10-2024 17:29:00
tenderQueryClose04-10-2024 17:30:00
technicalBidOpenNone
publishedDate21-09-2024 20:02:30
publishedByPostKPTCL_SE_TRM_CIR_BNGS
publishedByUserKPE21940 - SHAIKE KHADER VALI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPuttappa R V
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448365237
tenderSupplierListNone
tenderSchedule
createdTs1726928231754
version4
createdDateNone
modifiedDateNone
tenderNumberKPTCL/2024-25/BD/WORK_INDENT1246
titleConstruction of AEE TLI office above the 220 KV Control room building, Hoody.
descriptionConstruction of AEE TLI office above the 220 KV Control room building, Hoody.
categoryWORKS
categoryTextWorks
ecv1799492.18
deptNameKarnataka Power Transmission Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location4607
locationNameKPTCL SEE Transmission And Mantainance Circle BMAZ South Bengaluru
provisionalAmount18000000.0
groupOverheadTotalNone
fileNumberEPRC-069
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17269282320000NoneNoneBuildingsConstruction of AEE TLI office above the 220 KV Control room building, Hoody.1799492.18
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4052017157271Nonecode01Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. (KPWD SR 2023-24, Vol-2, P - 187 / I - 19.2.1)Cum2158.572158.572.0FalseNoneNoneFalseNoneFalse4317.140
4052018157271Nonecode02Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar (KPWD SR 2023-24, Vol-2, P - 187 / I - 19.7.3)Cum1335.641335.643.0FalseNoneNoneFalseNoneFalse4006.920
4052019157271Nonecode03Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles above 25 mm and up to 40 mm (KPWD SR 2023-24, Vol-2, P - 189 / I - 19.22.2)Cum96.0596.0570.0FalseNoneNoneFalseNoneFalse6723.50
4052020157271Nonecode04Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (KPWD SR 2023-24 Volume-I, Page 17 Item No:2.4.2)Cum9027.989027.9822.0FalseNoneNoneFalseNoneFalse198615.560
4052021157271Nonecode05Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work.(PWD SR 2023-24 Volume-2, Page 13 Item No: 6.2)Cum10355.4410355.4418.5FalseNoneNoneFalseNoneFalse191575.640
4052022157271Nonecode06Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. Buildings. (KPWD SR 2023-24 Volume-I, Page 18, Item No: 2.11(a))t116115.19116115.192.4FalseNoneNoneFalseNoneFalse278676.4560
4052023157271Nonecode07Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Volume-2, Page 41 Item No: 8.3.2)Sqm432.23432.23320.0FalseNoneNoneFalseNoneFalse138313.60
4052024157271Nonecode08Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200 mm (PWD SR 2023-24 Volume-2, Page 60, Item No: 9.12.5)Sqm1705.571705.5760.0FalseNoneNoneFalseNoneFalse102334.20
4052025157271Nonecode09Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR 2023-24, Volume-2, Page 50, Item No: 8.51)Sqm129.8129.8180.0FalseNoneNoneFalseNoneFalse23364.00
4052026157271Nonecode10Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Win Dows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR 2023-24, Volume-2, Page 108, Item No: 12.84)Sqm6519.856519.858.0FalseNoneNoneFalseNoneFalse52158.80
4052027157271Nonecode11Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR 2023-24, Volume-2, Page 108, Item No: 12.92)Sqm8106.018106.012.1FalseNoneNoneFalseNoneFalse17022.6210
4052028157271Nonecode12Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge. 42x50 mm PVC Extruded section (PWD SR 2023-24, Volume-2, Page 108, Item No: 12.83.2)Mtr310.22310.226.2FalseNoneNoneFalseNoneFalse1923.3640
4052029157271Nonecode13Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. (KPWD SR 2023-24 Volume-1, Page 17 Item No: 2.4.1)Cum8312.398312.398.0FalseNoneNoneFalseNoneFalse66499.120
4052030157271Nonecode14Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 litre/10 m² over and including one coat of Special primer applied @ 0.75 litre /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(PWD SR 2022 Volume-2, Page 46 Item No:8.33.1)Sqm205.08205.08170.0FalseNoneNoneFalseNoneFalse34863.60
4052031157271Nonecode15Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 litre/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, Volume-2, Page 132 Item No:8.31)Sqm231.04231.04160.0FalseNoneNoneFalseNoneFalse36966.40
4052032157271Nonecode16Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For PVC pipes 110mm dia., 6 kg/sqcm & class 3 (BWSSB SR 2023-24, P - 113 / I - 10.1.7)Mtr533.48533.4860.0FalseNoneNoneFalseNoneFalse32008.80
4052033157271Nonecode17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, panelling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (KPWD SR 2023-24, P - 88 / I - 11.35.2.3)Kgs755.44755.44280.0FalseNoneNoneFalseNoneFalse211523.20
4052034157271Nonecode18Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (KPWD SR 2023-24, P - 88 / I - 11.37.1)Sqm1282.421282.4216.5FalseNoneNoneFalseNoneFalse21159.930
4052035157271Nonecode19Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.. (KPWD SR 2023-24, P - 89 / I - 11.36.2)Sqm1275.931275.9353.0FalseNoneNoneFalseNoneFalse67624.290
4052036157271Nonecode20Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 25mm dia (KPWD SR 2023-24, P - 106 / I - 12.66.3)Mtr995.57995.577.0FalseNoneNoneFalseNoneFalse6968.990
4052037157271Nonecode21Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge (KPWD SR 2023-24, P - 219 / I - 22.24)Sqm1557.61557.69.0FalseNoneNoneFalseNoneFalse14018.40
4052038157271Nonecode22Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC Elbows (BWSSB SR 2023-24, P - 117 / I - 10.9.8)Nos391.99391.9912.0FalseNoneNoneFalseNoneFalse4703.880
4052039157271Nonecode23Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. 110 mm dia PVC couplers (BWSSB SR 2023-24, P - 116 / I - 10.8.8)Nos221.96221.9612.0FalseNoneNoneFalseNoneFalse2663.520
4052040157271Nonecode24Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(KPWD SR 2023-24 Volume-II, Page 75 Item No:11.2)Kg146.67146.67250.0FalseNoneNoneFalseNoneFalse36667.50
4052041157271Nonecode25Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (KPWD SR 2023-24 Volume-2, Page 132, Item No:14.7.1)Nos4000.444000.441.0FalseNoneNoneFalseNoneFalse4000.440
4052042157271Nonecode26Providing and fixing white vitreous China pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (KPWD SR 2023-24 Volume-2, Page 132, Item No:14.8)Nos1847.051847.051.0FalseNoneNoneFalseNoneFalse1847.050
4052043157271Nonecode27Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge for 20mm nominal OD pipes. (KPWD SR 2021-12, Vol-2, I - 13.33.2)Mtr290.48290.48100.0FalseNoneNoneFalseNoneFalse29048.00
4052044157271Nonecode28For 25mm nominal OD pipes. (KPWD SR 2021-12, Vol-2, I - 13.33.3)Mtr384.21384.2140.0FalseNoneNoneFalseNoneFalse15368.40
4052045157271Nonecode29Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy (KPWD SR 2021-12, Vol-2, P-139, I - 14.55(a))Nos1449.871449.876.0FalseNoneNoneFalseNoneFalse8699.220
4052046157271Nonecode30Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (KPWD SR 2021-12, Vol-2, P-123, I - 13.34)Ltr11.6811.684000.0FalseNoneNoneFalseNoneFalse46720.00
4052047157271Nonecode31Providing & fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete (KPWD SR 2021-12, Vol-2, P-23, I - 7.16)Sqm733.37733.3772.0FalseNoneNoneFalseNoneFalse52802.640
4052048157271Nonecode32Supplying and fixing regular MCB distribution boards on wall/old board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & N (PWD Ele SR 2023-24, P-18, I -5.19.1)Nos1610.821610.821.0FalseNoneNoneFalseNoneFalse1610.820
4052049157271Nonecode33Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sum (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch.(PWD Ele SR 2023-24, P-5, I -2.1.1)No369.93369.9315.0FalseNoneNoneFalseNoneFalse5548.950
4052050157271Nonecode34Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch. (PWD Ele SR 2023-24, P-5, I -2.1.2)No511.41511.4115.0FalseNoneNoneFalseNoneFalse7671.150
4052051157271Nonecode35Long point above 6Mtr up to 10Mtr from tapping point to out let via switch. (PWD Ele SR 2023-24, P-5, I -2.1.3)No739.86739.8615.0FalseNoneNoneFalseNoneFalse11097.90
4052052157271Nonecode36Supplying heavy gauge PVC Conduit Pipe 20 dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. A).20mm (PWD Ele SR 2023-24, P-2, I -1.1.1)Mtr85.6785.6750.0FalseNoneNoneFalseNoneFalse4283.50
4052053157271Nonecode37Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box. (PWD Ele SR 2023-24, P-2, I -1.5.1)No63.663.66.0FalseNoneNoneFalseNoneFalse381.60
4052054157271Nonecode38Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way.. (PWD Ele SR 2023-24, P-8, I -3.3.5)No284.26284.266.0FalseNoneNoneFalseNoneFalse1705.560
4052055157271Nonecode39Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP (PWD Ele SR 2023-24, P - 17 / I - 5.17.2)Nos959.22959.222.0FalseNoneNoneFalseNoneFalse1918.440
4052056157271Nonecode40Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch. (PWD Ele SR 2023-24, P - 9 / I - 3.6.1)Nos132.4132.450.0FalseNoneNoneFalseNoneFalse6620.00
4052057157271Nonecode41Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 W (PWD Ele SR 2023-24, P - 43 / I - 11.3.3)Nos1647.161647.1614.0FalseNoneNoneFalseNoneFalse23060.240
4052058157271Nonecode42Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders (PWD Ele SR 2023-24, P - 56 / I - 13.7.1)Nos158.36158.3614.0FalseNoneNoneFalseNoneFalse2217.040
4052059157271Nonecode43Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model (PWD Ele SR 2023-24, P - 30 / I - 6.3.1)Nos3873.233873.234.0FalseNoneNoneFalseNoneFalse15492.920
4052060157271Nonecode44Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (PWD Ele SR 2023-24, P - 57 / I - 13.11)Nos408.87408.874.0FalseNoneNoneFalseNoneFalse1635.480
4052061157271Nonecode451.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 . 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) (ESCOMs Ele SR 2023-24, P-13 /Sl. No. 199/ I-32.03)Mtr153.17153.1720.0FalseNoneNoneFalseNoneFalse3063.40
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17269282330000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17269282330000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17269282330000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17269282330000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17269282330000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17269282330000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17269282330000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17269282330000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17269282330000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17269282330000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
The bidder shall be registered KPWD/ CPWD Contractors Class-III and above.TrueTechnical Bid
The bidder shall have GST registration certificate issued by competent authority.TrueTechnical Bid
Eligible Tenderers will be qualified only if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under- Assessed available tender capacity AxNx2.5-B, For Reserved category AxNx5.0-BTrueTechnical Bid
The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.TrueTechnical Bid
The bidder shall submit the certificate of Income Tax returns and balance sheets/ statement of affairs ITR-4, ITR-4S, ITR-6 confirmed by the Income tax department for the year from FY 2020-21 to 2022-23 duly certified by the Charted Accountant.TrueTechnical Bid
The bidder shall enclose the Turn over statement for the above three years FY 2020-21 to 2022-23, duly certified by the Charted Accountant.TrueTechnical Bid
The bidder shall scan and upload all the above necessary certificates/ documents. Originals of all the uploaded documents should be produced at this office for verification during scrutiny of the bids.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone