createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726917456076
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd559500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose09-10-2024 16:30:00
tenderQueryClose05-10-2024 17:30:00
technicalBidOpen14-10-2024 16:00:00
publishedDate21-09-2024 18:04:19
publishedByPostAPMC_SEC_SVN
publishedByUserKPE21717 - PARAMESH G CHATRADAMATH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate08-10-2024 12:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSECRETARY APMC SAVANUR
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9731043307
tenderSupplierListNone
tenderSchedule
createdTs1726917456101
version6
createdDateNone
modifiedDateNone
tenderNumberAPMC/2024-25/OW/WORK_INDENT349
titleINFRASTRUCTURE FACILITIES (CONSTRUCTION OF CC ROAD, RCC DRAINS, PROVIDING UG CABLE, CONSTRUCTION OF COMPOUND WALL AND STORM WATER DRAIN) AT MAIN MARKET YARD OF APMC SAVANUR (UNDER RIDF-28 SCHEME 2022-23)
descriptionINFRASTRUCTURE FACILITIES (CONSTRUCTION OF CC ROAD, RCC DRAINS, PROVIDING UG CABLE, CONSTRUCTION OF COMPOUND WALL AND STORM WATER DRAIN) AT MAIN MARKET YARD OF APMC SAVANUR (UNDER RIDF-28 SCHEME 2022-23)
categoryWORKS
categoryTextWorks
ecv44012690.64
deptNameAgriculture Produce Marketing Committee
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5568
locationNameSECRETARY APMC Office SAVANUR
provisionalAmount50000000.0
groupOverheadTotal6713855.0
fileNumberAPMC/2024-25/WORKS-142
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17269174560000NoneNoneOther WorksINFRASTRUCTURE FACILITIES (CONSTRUCTION OF CC ROAD, RCC DRAINS, PROVIDING UG CABLE, CONSTRUCTION OF COMPOUND WALL AND STORM WATER DRAIN) AT MAIN MARKET YARD OF APMC SAVANUR (UNDER RIDF-28 SCHEME 2022-23)37298835.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4048660157170NoneSVR01Clearing and grubbing road land including uprooting rank vegetation grass bushes shrubs saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness By Mechanical Means using Dozer In area of thorny jungle with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Sqm484.0484.028.0FalseNoneNoneFalseNoneFalse13552.00
4048661157170NoneSVR02Cutting open existing bund by manual means and forming temperary diversion channel including placing the excavated soil in specified dump area & all necessary with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum394.0394.01280.0FalseNoneNoneFalseNoneFalse504320.00
4048662157170NoneSVR03Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum1029.01029.010.5187FalseNoneNoneFalseNoneFalse10823.74230
4048663157170NoneSVR04Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum2426.02426.02.3489FalseNoneNoneFalseNoneFalse5698.43140
4048664157170NoneSVR05Cleaning of reinforcement from rust by Alkaline solution thoroughly with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Sqm184.0184.026.0999FalseNoneNoneFalseNoneFalse4802.38160
4048665157170NoneSVR06Epoxy bonding of new concrete to old concrete with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Sqm771.0771.00.81FalseNoneNoneFalseNoneFalse624.510
4048666157170NoneSVR07Dismantling roofing including ridges, hips, valleys and gutters etc and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. Asbestos cement sheet with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Sqm51.051.0344.25FalseNoneNoneFalseNoneFalse17556.750
4048667157170NoneSVR08Removing the old paint from steel and / or other metal surface with hand scraping and making surface even including cost of labour, with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Sqm121.0121.0335.52FalseNoneNoneFalseNoneFalse40597.920
4048668157170NoneSVR09Earth work excavation for Foundation by mechanical means In all kinds of soils Depth upto 3 mwidth, & Depth for all works as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum102.0102.0962.79FalseNoneNoneFalseNoneFalse98204.580
4048669157170NoneSVR10Earth work excavation for Foundation by mechanical means In all kinds of soils, width, & Depth for all works as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.. including Cost of De-watering uptoCum107.1107.11534.52FalseNoneNoneFalseNoneFalse164347.0920
4048670157170NoneSVR11Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum2682.02682.0329.8545FalseNoneNoneFalseNoneFalse884669.7690
4048671157170NoneSVR12Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum5664.05664.088.428FalseNoneNoneFalseNoneFalse500856.1920
4048672157170NoneSVR13Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6217.06217.0139.2FalseNoneNoneFalseNoneFalse865406.40
4048673157170NoneSVR14Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work Drain raft ConcreteCum6639.156639.1513.2FalseNoneNoneFalseNoneFalse87636.780
4048674157170NoneSVR15Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work Drain wall ConcreteCum8536.058536.0513.2FalseNoneNoneFalseNoneFalse112675.860
4048675157170NoneSVR16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work SWD RAFT CONCRETECum6652.86652.8197.8399FalseNoneNoneFalseNoneFalse1316189.286720
4048676157170NoneSVR17Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work SWD WALL & SLABCum7603.27603.2366.4899FalseNoneNoneFalseNoneFalse2786496.007680
4048677157170NoneSVR18Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6323.06323.051.6075FalseNoneNoneFalseNoneFalse326314.22250
4048678157170NoneSVR19Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6842.886842.8852.8FalseNoneNoneFalseNoneFalse361304.0640
4048679157170NoneSVR20Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum7128.07128.077.93FalseNoneNoneFalseNoneFalse555485.040
4048680157170NoneSVR21Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum11633.0911633.0918.7365FalseNoneNoneFalseNoneFalse217963.3907850
4048681157170NoneSVR22Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum10749.0910749.0914.2312FalseNoneNoneFalseNoneFalse152972.4496080
4048682157170NoneSVR23Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6287.06287.021.6675FalseNoneNoneFalseNoneFalse136223.57250
4048683157170NoneSVR24Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6217.06217.02.745FalseNoneNoneFalseNoneFalse17065.6650
4048684157170NoneSVR25Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work DRAIN & SWDMT79011.079011.080.0FalseNoneNoneFalseNoneFalse6320880.00
4048685157170NoneSVR26Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work for BuildingsMT89457.089457.011.12FalseNoneNoneFalseNoneFalse994761.840
4048686157170NoneSVR27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm1310.01310.0350.1FalseNoneNoneFalseNoneFalse458631.00
4048687157170NoneSVR28Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm349.0349.0771.82FalseNoneNoneFalseNoneFalse269365.180
4048688157170NoneSVR29Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum2677.02677.0174.75FalseNoneNoneFalseNoneFalse467805.750
4048689157170NoneSVR30Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drain- age of surface water including of labour, materials, scaffolding, usage of machinery, curing, with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm1170.01170.0111.15FalseNoneNoneFalseNoneFalse130045.50
4048690157170NoneSVR31Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum433.0433.0197.38FalseNoneNoneFalseNoneFalse85465.540
4048691157170NoneSVR32Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKg113.0113.07976.48FalseNoneNoneFalseNoneFalse901342.240
4048692157170NoneSVR33Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. (Made of G.I. wire of dia 4 mm)Sqm803.0803.01249.2FalseNoneNoneFalseNoneFalse1003107.60
4048693157170NoneSVR34Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm89.089.0850.12FalseNoneNoneFalseNoneFalse75660.680
4048694157170NoneSVR35Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm115.0115.01591.32FalseNoneNoneFalseNoneFalse183001.80
4048695157170NoneSVR36Providing & fixing 20 mm thick compressible fibre board in expansion joint with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr137.0137.047.5FalseNoneNoneFalseNoneFalse6507.50
4048696157170NoneSVR37Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr231.0231.047.5FalseNoneNoneFalseNoneFalse10972.50
4048697157170NoneSVR38Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum105.0105.0250.68FalseNoneNoneFalseNoneFalse26321.40
4048698157170NoneSVR39Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum474.0474.03488.83FalseNoneNoneFalseNoneFalse1653705.420
4048699157170NoneSVR40Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum2487.02487.0184.45FalseNoneNoneFalseNoneFalse458727.150
4048700157170NoneSVR41Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tiper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting withvibratory rollertoachievethedesireddensity. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum2559.02559.0152.25FalseNoneNoneFalseNoneFalse389607.750
4048701157170NoneSVR42Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum4920.04920.033.0FalseNoneNoneFalseNoneFalse162360.00
4048702157170NoneSVR43Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepare sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6754.06754.075.9FalseNoneNoneFalseNoneFalse512628.60
4048703157170NoneSVR44Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm size with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr463.0463.0520.0FalseNoneNoneFalseNoneFalse240760.00
4048704157170NoneSVR45Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm109.0109.0234.0FalseNoneNoneFalseNoneFalse25506.00
4048705157170NoneSVR46Construction of median and Island above road level with approved material brought from borrow pits, spread, sloped and compacted as per clause 408 with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum543.0543.0141.44FalseNoneNoneFalseNoneFalse76801.920
4048706157170NoneSVR47Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work (WMM/WBM Base to be paid separately if necessary as per relevant technical specification)Sqm1068.01068.01015.0FalseNoneNoneFalseNoneFalse1084020.00
4048707157170NoneSVR48Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum568.0568.0334.8FalseNoneNoneFalseNoneFalse190166.40
4048708157170NoneSVR49Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr451.0451.015.5FalseNoneNoneFalseNoneFalse6990.50
4048709157170NoneSVR50Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr1074.01074.051.8FalseNoneNoneFalseNoneFalse55633.20
4048710157170NoneSVR51Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.40 mm dia 2.5 mm thick. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr149.0149.0240.0FalseNoneNoneFalseNoneFalse35760.00
4048711157170NoneSVR52Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible coper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 2.5 mm2. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr113.0113.0994.0FalseNoneNoneFalseNoneFalse112322.00
4048712157170NoneSVR53Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing twocoats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7.Erection of heavy duty pole on Footpath / median 10Mt (5Mt Hb,165.1mm dia 4.85mm thick x3M Hm, 139.7mm dia 4.50mm thick x 2M Ht114.3mm dia 3.65mm thick) as per IS 410 SP 47. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo19100.019100.060.0FalseNoneNoneFalseNoneFalse1146000.00
4048713157170NoneSVR54Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories.Single bracket 1.5 Mtr. Length. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1461.01461.049.0FalseNoneNoneFalseNoneFalse71589.00
4048714157170NoneSVR55Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole with necessary two coats of painting, with all other accessories.Double bracket 2x1.5 m. Length with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo2335.02335.011.0FalseNoneNoneFalseNoneFalse25685.00
4048715157170NoneSVR56Supplying and fixing of 4 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 40 Amps. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo6119.06119.03.0FalseNoneNoneFalseNoneFalse18357.00
4048716157170NoneSVR57Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo14520.014520.03.0FalseNoneNoneFalseNoneFalse43560.00
4048717157170NoneSVR58Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo4843.04843.03.0FalseNoneNoneFalseNoneFalse14529.00
4048718157170NoneSVR59Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 120 W. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo10060.010060.071.0FalseNoneNoneFalseNoneFalse714260.00
4048719157170NoneSVR60Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo162.0162.071.0FalseNoneNoneFalseNoneFalse11502.00
4048720157170NoneSVR61Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo8487.08487.029.0FalseNoneNoneFalseNoneFalse246123.00
4048721157170NoneSVR62Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 36 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo21424.021424.08.0FalseNoneNoneFalseNoneFalse171392.00
4048722157170NoneSVR63Supplying and fixing of Shunt trip suitable for MCCB.CBCT with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1703.01703.04.0FalseNoneNoneFalseNoneFalse6812.00
4048723157170NoneSVR64Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo415.0415.0196.0FalseNoneNoneFalseNoneFalse81340.00
4048724157170NoneSVR65Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo739.0739.088.0FalseNoneNoneFalseNoneFalse65032.00
4048725157170NoneSVR66Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898.6-32 Amps TPN. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1717.01717.08.0FalseNoneNoneFalseNoneFalse13736.00
4048726157170NoneSVR67Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo3088.03088.051.0FalseNoneNoneFalseNoneFalse157488.00
4048727157170NoneSVR68Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo9255.09255.04.0FalseNoneNoneFalseNoneFalse37020.00
4048728157170NoneSVR69Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo9315.09315.017.0FalseNoneNoneFalseNoneFalse158355.00
4048729157170NoneSVR70Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo562.0562.051.0FalseNoneNoneFalseNoneFalse28662.00
4048730157170NoneSVR71Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo515.0515.0186.0FalseNoneNoneFalseNoneFalse95790.00
4048731157170NoneSVR72Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr3435.03435.0136.0FalseNoneNoneFalseNoneFalse467160.00
4048732157170NoneSVR73Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr305.0305.0126.0FalseNoneNoneFalseNoneFalse38430.00
4048733157170NoneSVR74Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr395.0395.0126.0FalseNoneNoneFalseNoneFalse49770.00
4048734157170NoneSVR75Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr555.0555.048.0FalseNoneNoneFalseNoneFalse26640.00
4048735157170NoneSVR76Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr756.0756.048.0FalseNoneNoneFalseNoneFalse36288.00
4048736157170NoneSVR77Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 150 x 75 x 6 mm C channel with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr926.0926.048.0FalseNoneNoneFalseNoneFalse44448.00
4048737157170NoneSVR78Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm0.50.52750000.0FalseNoneNoneFalseNoneFalse1375000.00
4048738157170NoneSVR79Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 40 Amps. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo2258.02258.06.0FalseNoneNoneFalseNoneFalse13548.00
4048739157170NoneSVR80Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKvar480.0480.060.0FalseNoneNoneFalseNoneFalse28800.00
4048740157170NoneSVR81Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo21640.021640.02.0FalseNoneNoneFalseNoneFalse43280.00
4048741157170NoneSVR82Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach1330.01330.02.0FalseNoneNoneFalseNoneFalse2660.00
4048742157170NoneSVR83FRLS PVC insulated 1100V grade, multistrand coper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.6 sq.mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr92.092.0750.0FalseNoneNoneFalseNoneFalse69000.00
4048743157170NoneSVR84FRLS PVC insulated 1100V grade, multistrand coper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.10 sq.mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr167.0167.0400.0FalseNoneNoneFalseNoneFalse66800.00
4048744157170NoneSVR85Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo3510.03510.064.0FalseNoneNoneFalseNoneFalse224640.00
4048745157170NoneSVR86Supplying and running of GI/Coper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr82.082.0480.0FalseNoneNoneFalseNoneFalse39360.00
4048746157170NoneSVR87Supplying and running of GI/Coper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 50x6mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr218.0218.048.0FalseNoneNoneFalseNoneFalse10464.00
4048747157170NoneSVR88Supplying and running GI/Coper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Coper Wire with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr105.0105.0100.0FalseNoneNoneFalseNoneFalse10500.00
4048748157170NoneSVR89600 x 600 x 3 mm Coper plate. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach7421.07421.08.0FalseNoneNoneFalseNoneFalse59368.00
4048749157170NoneSVR901.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm141842.0141842.02.6FalseNoneNoneFalseNoneFalse368789.20
4048750157170NoneSVR91Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm20886.020886.02.6FalseNoneNoneFalseNoneFalse54303.60
4048751157170NoneSVR921.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 35 Sqmm, 4 Core, (15 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm176070.0176070.00.25FalseNoneNoneFalseNoneFalse44017.50
4048752157170NoneSVR931.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm317912.0317912.01.4FalseNoneNoneFalseNoneFalse445076.80
4048753157170NoneSVR94Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.35 to 95 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm31139.031139.01.65FalseNoneNoneFalseNoneFalse51379.350
4048754157170NoneSVR951.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm554655.0554655.00.25FalseNoneNoneFalseNoneFalse138663.750
4048755157170NoneSVR96Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm32278.032278.00.25FalseNoneNoneFalseNoneFalse8069.50
4048756157170NoneSVR97Heavy Duty Coper Terminal Long Barrel.16/25 Sqmm Coper Terminal, Apprx Wt: 11 Gm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo27.027.0336.0FalseNoneNoneFalseNoneFalse9072.00
4048757157170NoneSVR98Heavy Duty Coper Terminal Long Barrel.70 Sqmm Coper Terminal, Apprx Wt: 38 Gm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo89.089.0104.0FalseNoneNoneFalseNoneFalse9256.00
4048758157170NoneSVR99Heavy Duty Coper Terminal Long Barrel.1150 Sqmm Coper Terminal, Apprx Wt: 98 Gm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo183.0183.0128.0FalseNoneNoneFalseNoneFalse23424.00
4048759157170NoneSVR100Brass Cable Gland 25mm.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo79.079.0110.0FalseNoneNoneFalseNoneFalse8690.00
4048760157170NoneSVR101Brass Cable Gland 32mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo95.095.020.0FalseNoneNoneFalseNoneFalse1900.00
4048761157170NoneSVR102Brass Cable Gland 40mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo148.0148.030.0FalseNoneNoneFalseNoneFalse4440.00
4048762157170NoneSVR103Brass Cable Gland 45mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo197.0197.030.0FalseNoneNoneFalseNoneFalse5910.00
4048763157170NoneSVR104Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr (BESCOM SR PART-4,P.NO.8, IT No-29.02) -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum484.0484.01500.0FalseNoneNoneFalseNoneFalse726000.00
4048764157170NoneSVR105Supply of RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo7076.07076.04.0FalseNoneNoneFalseNoneFalse28304.00
4048765157170NoneSVR106Fixing of RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1742.01742.04.0FalseNoneNoneFalseNoneFalse6968.00
4048766157170NoneSVR107Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet646.0646.08.0FalseNoneNoneFalseNoneFalse5168.00
4048767157170NoneSVR108Fixing of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet272.0272.08.0FalseNoneNoneFalseNoneFalse2176.00
4048768157170NoneSVR109Supply of DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet20928.020928.02.0FalseNoneNoneFalseNoneFalse41856.00
4048769157170NoneSVR110Fixing of DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet5392.05392.02.0FalseNoneNoneFalseNoneFalse10784.00
4048770157170NoneSVR111Supply of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNos205.0205.024.0FalseNoneNoneFalseNoneFalse4920.00
4048771157170NoneSVR112Supply of 11 kV, 45 KN Polymeric Insulator with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo186.0186.012.0FalseNoneNoneFalseNoneFalse2232.00
4048772157170NoneSVR113Supply of Guy Set Complete with No. 15 Strain Insulator with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet1170.01170.012.0FalseNoneNoneFalseNoneFalse14040.00
4048773157170NoneSVR114Fixing of Guy Set Complete with No. 15 Strain Insulator with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet593.0593.012.0FalseNoneNoneFalseNoneFalse7116.00
4048774157170NoneSVR115Supply of Rabbit ACSR Conductor with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm46234.046234.00.19FalseNoneNoneFalseNoneFalse8784.460
4048775157170NoneSVR116Laying of Rabbit ACSR Conductor with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm4361.04361.00.19FalseNoneNoneFalseNoneFalse828.590
4048776157170NoneSVR117Supply of PG Clamps for Rabbit Conductor with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo102.0102.012.0FalseNoneNoneFalseNoneFalse1224.00
4048777157170NoneSVR118Supply of Spiral Earth Electrode with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo239.0239.08.0FalseNoneNoneFalseNoneFalse1912.00
4048778157170NoneSVR119Fixing of Spiral Earth Electrode with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo93.093.08.0FalseNoneNoneFalseNoneFalse744.00
4048779157170NoneSVR120Supply of EG Stirrups with GI wire lacing with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet276.0276.07.0FalseNoneNoneFalseNoneFalse1932.00
4048780157170NoneSVR121Fixing ofEG Stirrups with GI wire lacing with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet160.0160.07.0FalseNoneNoneFalseNoneFalse1120.00
4048781157170NoneSVR122Fixing ofGuy concreting with Boulders Mud and Sand with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo250.0250.08.0FalseNoneNoneFalseNoneFalse2000.00
4048782157170NoneSVR123Supply of Caution/Danger Board with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo150.0150.06.0FalseNoneNoneFalseNoneFalse900.00
4048783157170NoneSVR124Fixing ofCaution/Danger Board with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo80.080.06.0FalseNoneNoneFalseNoneFalse480.00
4048784157170NoneSVR125Supply of Anti Climbing Device (12 Mtr GI Barbed Wire) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach89.089.06.0FalseNoneNoneFalseNoneFalse534.00
4048785157170NoneSVR126Fixing of Anti Climbing Device (12 Mtr GI Barbed Wire) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach42.042.06.0FalseNoneNoneFalseNoneFalse252.00
4048786157170NoneSVR127Supply of 11 kV, 3 Phase Aerial Bunched Cable 3x95 + 70 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm959730.0959730.00.19FalseNoneNoneFalseNoneFalse182348.70
4048787157170NoneSVR128Laying of11 kV, 3 Phase Aerial Bunched Cable 3x95 + 70 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm34765.034765.00.19FalseNoneNoneFalseNoneFalse6605.350
4048788157170NoneSVR129Supply of Cable Straight thru' joint kits suitable for 95 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet7685.07685.06.0FalseNoneNoneFalseNoneFalse46110.00
4048789157170NoneSVR130Fixing ofCable Straight thru' joint kits suitable for 95 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet1424.01424.06.0FalseNoneNoneFalseNoneFalse8544.00
4048790157170NoneSVR131Supply of 11 kV AB CableTermination Kits for 95 to 120 Sqmmwith all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet2856.02856.06.0FalseNoneNoneFalseNoneFalse17136.00
4048791157170NoneSVR132Fixing of11 kV AB CableTermination Kits for 95 to 120 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet1139.01139.06.0FalseNoneNoneFalseNoneFalse6834.00
4048792157170NoneSVR133Supply of Suspension Clamp Assembly 16 to 70 mm (Excluding pole clamp & Eye Hook ) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet221.0221.012.0FalseNoneNoneFalseNoneFalse2652.00
4048793157170NoneSVR134Fixing of Suspension Clamp Assembly 16 to 70 mm (Excluding pole clamp & Eye Hook ) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet96.096.012.0FalseNoneNoneFalseNoneFalse1152.00
4048794157170NoneSVR135Supply of Pole clamp for HT/LT AB cable with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet109.0109.012.0FalseNoneNoneFalseNoneFalse1308.00
4048795157170NoneSVR136Fixing of Pole clamp for HT/LT AB cable with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet160.0160.012.0FalseNoneNoneFalseNoneFalse1920.00
4048796157170NoneSVR137Supply of Eye Hook (Flat type) for fixing Clamps with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet102.0102.012.0FalseNoneNoneFalseNoneFalse1224.00
4048797157170NoneSVR138Supply of Dead End Clamp/Anchor Clamp Assembly 16 to 70 Sqmm (excluding pole clamps and Eye hook) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet232.0232.016.0FalseNoneNoneFalseNoneFalse3712.00
4048798157170NoneSVR139Fixing ofDead End Clamp/Anchor Clamp Assembly 16 to 70 Sqmm (excluding pole clamps and Eye hook) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet192.0192.016.0FalseNoneNoneFalseNoneFalse3072.00
4048799157170NoneSVR140Supply of End Caps with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo23.023.016.0FalseNoneNoneFalseNoneFalse368.00
4048800157170NoneSVR141Fixing of End Caps with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo10.010.016.0FalseNoneNoneFalseNoneFalse160.00
4048801157170NoneSVR142Supply of 11 kV Lightning Arrester Metal Oxide 10 kV, 5 kA Polymeric Type with ground disconnector with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet4752.04752.02.0FalseNoneNoneFalseNoneFalse9504.00
4048802157170NoneSVR143Fixing of11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA Polymeric Type with ground disconnector with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet119.0119.02.0FalseNoneNoneFalseNoneFalse238.00
4048803157170NoneSVR144Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet20928.020928.010.0FalseNoneNoneFalseNoneFalse209280.00
4048804157170NoneSVR145Fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet5372.05372.010.0FalseNoneNoneFalseNoneFalse53720.00
4048805157170NoneSVR146Supply of 11 kV 45 KN Polymeric Insulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo186.0186.060.0FalseNoneNoneFalseNoneFalse11160.00
4048806157170NoneSVR147Supply of Guy Set Complete with No. 15 Strain Insulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet1170.01170.020.0FalseNoneNoneFalseNoneFalse23400.00
4048807157170NoneSVR148Laying of Guy Set Complete with No. 15 Strain Insulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet593.0593.020.0FalseNoneNoneFalseNoneFalse11860.00
4048808157170NoneSVR149Supply of Spiral Earth Electrode. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo239.0239.020.0FalseNoneNoneFalseNoneFalse4780.00
4048809157170NoneSVR150Fixing of Spiral Earth Electrode. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo93.093.020.0FalseNoneNoneFalseNoneFalse1860.00
4048810157170NoneSVR151Laying of Guy concreting with Boulders, Mud and Sand. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo250.0250.020.0FalseNoneNoneFalseNoneFalse5000.00
4048811157170NoneSVR152Supply of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo150.0150.010.0FalseNoneNoneFalseNoneFalse1500.00
4048812157170NoneSVR153Fixing of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo80.080.010.0FalseNoneNoneFalseNoneFalse800.00
4048813157170NoneSVR154Supply of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach89.089.020.0FalseNoneNoneFalseNoneFalse1780.00
4048814157170NoneSVR155Fixing of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach42.042.020.0FalseNoneNoneFalseNoneFalse840.00
4048815157170NoneSVR156Supply of 11 kV, 400 Amps Double Break GOS. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet21260.021260.010.0FalseNoneNoneFalseNoneFalse212600.00
4048816157170NoneSVR157Fixing of 11 kV, 400 Amps Double Break GOS. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet1214.01214.010.0FalseNoneNoneFalseNoneFalse12140.00
4048817157170NoneSVR158Supply of H-Frame for mounting GOS. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo4332.04332.010.0FalseNoneNoneFalseNoneFalse43320.00
4048818157170NoneSVR159Fixing of H-Frame for mounting GOS. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo323.0323.010.0FalseNoneNoneFalseNoneFalse3230.00
4048819157170NoneSVR160Supply of DOLO Cut Out. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet5872.05872.010.0FalseNoneNoneFalseNoneFalse58720.00
4048820157170NoneSVR161Fixing of DOLO Cut Out. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSet237.0237.010.0FalseNoneNoneFalseNoneFalse2370.00
4048821157170NoneSVR162Concreting Material for 9mtrs RCC Poles structure.base concreting cc 1:4:8,500x650x150mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo312.0312.020.0FalseNoneNoneFalseNoneFalse6240.00
4048822157170NoneSVR163pole concreting cc 1:2:4,650x500x1700mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo4495.04495.020.0FalseNoneNoneFalseNoneFalse89900.00
4048823157170NoneSVR164providing coping for poles with cc 1:2:4 and as per norms. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo312.0312.020.0FalseNoneNoneFalseNoneFalse6240.00
4048824157170NoneSVR165Supply and Fixing of GI Wire 8 SWG. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKg75.0475.0420.0FalseNoneNoneFalseNoneFalse1500.80
4048825157170NoneSVR166Laying of 1RX0.3 KM Length of 11 kV, 3x240 Sqmm XLPE UG Cable Using Conventional Laying with Excavation in Soil11 kV, 3X240 Sqmm XLPE UG Cable. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm1656048.01656048.00.24FalseNoneNoneFalseNoneFalse397451.520
4048826157170NoneSVR167Supply of Cable termination kit Outdoor HS Type Suitable for 3x240 Sqmm Cable. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workPer Kit5318.05318.010.0FalseNoneNoneFalseNoneFalse53180.00
4048827157170NoneSVR168Supply of Cable Covering Tiles 250x125x40 mm or 125x125x40 mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo5.135.13500.0FalseNoneNoneFalseNoneFalse2565.00
4048828157170NoneSVR169Supply of Artificial/Manufacture Sand with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum1786.01786.05.0FalseNoneNoneFalseNoneFalse8930.00
4048829157170NoneSVR170Supply of RCC Hume pipe, 2000 mm Long, 150 mm Dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo307.0307.015.0FalseNoneNoneFalseNoneFalse4605.00
4048830157170NoneSVR171Supply of Collars for RCC Hume Pipe. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo82.082.015.0FalseNoneNoneFalseNoneFalse1230.00
4048831157170NoneSVR172Supply of GI Pipe, 100 mm Dia for drain crossing, cable raising etc., with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr1235.01235.080.0FalseNoneNoneFalseNoneFalse98800.00
4048832157170NoneSVR173Supply of Route and Joint Indicating Stones. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo133.0133.010.0FalseNoneNoneFalseNoneFalse1330.00
4048833157170NoneSVR174Cable trench excavation, 1000x0.6x1=600 Ordinary soil with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum262.0262.036.0FalseNoneNoneFalseNoneFalse9432.00
4048834157170NoneSVR175Laying of cable in trench. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm64153.064153.00.24FalseNoneNoneFalseNoneFalse15396.720
4048835157170NoneSVR176Refilling and consolidation. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum160.0160.036.0FalseNoneNoneFalseNoneFalse5760.00
4048836157170NoneSVR177Making of cable termination. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo2658.02658.010.0FalseNoneNoneFalseNoneFalse26580.00
4048837157170NoneSVR178Covering the cable with tile. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm4367.04367.00.24FalseNoneNoneFalseNoneFalse1048.080
4048838157170NoneSVR179Spreading Sand and forming with Sand round the cable. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm14810.014810.00.24FalseNoneNoneFalseNoneFalse3554.40
4048839157170NoneSVR180Laying of RCC Hume pipe. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr69.069.015.0FalseNoneNoneFalseNoneFalse1035.00
4048840157170NoneSVR181Laying of GI Pipe. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr93.093.080.0FalseNoneNoneFalseNoneFalse7440.00
4048841157170NoneSVR182Laying of Route and Joint indicating stone. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo116.0116.010.0FalseNoneNoneFalseNoneFalse1160.00
4048842157170NoneSVR183Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm889666.0889666.00.95FalseNoneNoneFalseNoneFalse845182.70
4048843157170NoneSVR184Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKit3744.03744.012.0FalseNoneNoneFalseNoneFalse44928.00
4048844157170NoneSVR185Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKit4067.04067.015.0FalseNoneNoneFalseNoneFalse61005.00
4048845157170NoneSVR186Supply of Cable covering tiles 250x125x40mm.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo10.2510.25600.0FalseNoneNoneFalseNoneFalse6150.00
4048846157170NoneSVR187Supply of River sand. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum1760.01760.024.0FalseNoneNoneFalseNoneFalse42240.00
4048847157170NoneSVR188Supply of RCC humepipes 2000mm long 150mm dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo307.0307.040.0FalseNoneNoneFalseNoneFalse12280.00
4048848157170NoneSVR189Supply of Collars for RCC hume pipes. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo82.082.040.0FalseNoneNoneFalseNoneFalse3280.00
4048849157170NoneSVR190Supply of GI pipe 150mm dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr1021.01021.080.0FalseNoneNoneFalseNoneFalse81680.00
4048850157170NoneSVR191Supply of Route and Joint indicating stones with MS Anchor rod. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo133.0133.050.0FalseNoneNoneFalseNoneFalse6650.00
4048851157170NoneSVR192Earth work excavation for cable treanch of 0.5 to 0.75Mtr Width and Depth up to 1Mtr .BESCOM SR PART-4,PAGE-8,ITEAM NO-29.02 -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum484.0484.080.0FalseNoneNoneFalseNoneFalse38720.00
4048852157170NoneSVR193Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm61322.061322.00.95FalseNoneNoneFalseNoneFalse58255.90
4048853157170NoneSVR194Retailing the cable trenches with selected availble earth from trench excavation including watering,Consolidation in layers of 15Cm thickness including depositing of the surplus earth with a lead of 200Mtrs. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum58.058.0160.0FalseNoneNoneFalseNoneFalse9280.00
4048854157170NoneSVR195Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo2658.02658.016.0FalseNoneNoneFalseNoneFalse42528.00
4048855157170NoneSVR196Covering the cables with tiles. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm4367.04367.01.6FalseNoneNoneFalseNoneFalse6987.20
4048856157170NoneSVR197Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm . with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm14810.014810.01.6FalseNoneNoneFalseNoneFalse23696.00
4048857157170NoneSVR198Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete.RCC Pipe.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
4048858157170NoneSVR199Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workMtr93.093.080.0FalseNoneNoneFalseNoneFalse7440.00
4048859157170NoneSVR200Fixing of Route Joint Indicating Slab.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo116.0116.0200.0FalseNoneNoneFalseNoneFalse23200.00
4048860157170NoneSVR201Supply of Providing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.supply of LT CT's 0.5 Accuracy Class Ring Type Ratio 100/5 for 50/63 kVA DTC with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo660.0660.01.0FalseNoneNoneFalseNoneFalse660.00
4048861157170NoneSVR202Fixing of Providing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.supply of LT CT's 0.5 Accuracy Class Ring Type Ratio 100/5 for 50/63 kVA DTC with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo105.0105.01.0FalseNoneNoneFalseNoneFalse105.00
4048862157170NoneSVR203Supply of Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.supply of LT CT's 0.5 Accuracy Class Ring Type Ratio 150/5 for 100 kVA DTC. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo494.0494.03.0FalseNoneNoneFalseNoneFalse1482.00
4048863157170NoneSVR204Fixing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.supply of LT CT's 0.5 Accuracy Class Ring Type Ratio 150/5 for 100 kVA DTC. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo105.0105.03.0FalseNoneNoneFalseNoneFalse315.00
4048864157170NoneSVR205supply of Electronic Trivector Meter 3 Phase, 4 Wire, 0.5 Accuracy Class. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo3396.03396.04.0FalseNoneNoneFalseNoneFalse13584.00
4048865157170NoneSVR206fixing of Electronic Trivector Meter 3 Phase, 4 Wire, 0.5 Accuracy Class. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo480.0480.04.0FalseNoneNoneFalseNoneFalse1920.00
4048866157170NoneSVR207supply of Weather Proof, Verming Proof LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the existing ground. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo3644.03644.04.0FalseNoneNoneFalseNoneFalse14576.00
4048867157170NoneSVR208fixing of Weather Proof, Verming Proof LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the existing ground. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo550.0550.04.0FalseNoneNoneFalseNoneFalse2200.00
4048868157170NoneSVR209Earth work excavation for Foundation by mechanical means In all kinds of soils, width, & Depth for all works as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum102.0102.038.88FalseNoneNoneFalseNoneFalse3965.760
4048869157170NoneSVR210Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum5664.05664.03.84FalseNoneNoneFalseNoneFalse21749.760
4048870157170NoneSVR211Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6789.966789.9632.4FalseNoneNoneFalseNoneFalse219994.7040
4048871157170NoneSVR212Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing andremoving scaffolding, including cost of materials, labour, curing completeas per specifications and as per directions of Engineer-in-charge.Sqm312.0312.041.4FalseNoneNoneFalseNoneFalse12916.80
4048872157170NoneSVR213Erection of 11kV/433V, 100 kVA, 3 Phase 50 Cys Distribution Transformer BEE - 4 Star Rated with Oil with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1590.01590.04.0FalseNoneNoneFalseNoneFalse6360.00
4048873157170NoneSVR214Releasing of Conductor.Rabbit with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm4012.04012.05.938FalseNoneNoneFalseNoneFalse23823.2560
4048874157170NoneSVR215Releasing of Single/3 Phase Meter with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo103.0103.040.0FalseNoneNoneFalseNoneFalse4120.00
4048875157170NoneSVR216Any Dismantling work.90% of the Pole erection charges. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo1567.81567.852.0FalseNoneNoneFalseNoneFalse81525.60
4048876157170NoneSVR217Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at workspot) NOTE:- Consolidated amount for both loading and unloading. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo142.0142.052.0FalseNoneNoneFalseNoneFalse7384.00
4048877157170NoneSVR218Releasing of HT cable after excavation refilling, consolidation Rewinding to the drum etc. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKm59436.059436.00.25FalseNoneNoneFalseNoneFalse14859.00
4048878157170NoneSVR219Releasing and Refixing Insulator of 11 kV Pin Insulator with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo48.048.0120.0FalseNoneNoneFalseNoneFalse5760.00
4048879157170NoneSVR220Releasing and Refixing Insulator of 11 kV Dead End Insulator Disc, Strain etc with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workNo58.058.065.0FalseNoneNoneFalseNoneFalse3770.00
4048880157170NoneSVR221Earth work excavation for Foundation by mechanical means In all kinds of soils, width, & Depth for all works as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.Cum102.0102.015.54FalseNoneNoneFalseNoneFalse1585.080
4048881157170NoneSVR222Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2682.02682.02.58FalseNoneNoneFalseNoneFalse6919.560
4048882157170NoneSVR223Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum5664.05664.02.58FalseNoneNoneFalseNoneFalse14613.120
4048883157170NoneSVR224Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum6287.06287.06.3FalseNoneNoneFalseNoneFalse39608.10
4048884157170NoneSVR225Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workKg113.0113.02472.0FalseNoneNoneFalseNoneFalse279336.00
4048885157170NoneSVR226Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. (Made of G.I. wire of dia 4 mm)Sqm803.0803.0259.2FalseNoneNoneFalseNoneFalse208137.60
4048886157170NoneSVR227Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workSqm115.0115.0518.4FalseNoneNoneFalseNoneFalse59616.00
4048887157170NoneSVR228Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum1663.01663.021.375FalseNoneNoneFalseNoneFalse35546.6250
4048888157170NoneSVR229Providing Laying Burnt Brick (Class 35 Modular) for laying of UG cable base support with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work A-38Each8.08.020000.0FalseNoneNoneFalseNoneFalse160000.00
4048889157170NoneSVR230Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workCum1965.01965.075.0FalseNoneNoneFalseNoneFalse147375.00
4048890157170NoneSVR231Reinforcement CC M15 grade KM stone of standard design as per IRC: 8-1980, fixing in position including painting and printing etc 200 M stone (precast) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the workEach842.0842.020.0FalseNoneNoneFalseNoneFalse16840.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17269174570000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17269174570000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17269174570000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17269174570000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17269174570000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17269175000001NoneNoneELIGIBILITYAll Other General Conditions of Eligibility as per tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneAll other documents should be as per tender documentOthersAll other documents should be as per tender document
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- All other documents should be as per tender document
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Registration CertificateTrueTechnical Bid
Work done CertificateTrueTechnical Bid
Line of creditTrueTechnical Bid
PancardTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
EARTH WORK 3242 CUMTrueTechnical Bid
RCC & PCC 944 CUMTrueTechnical Bid
STEEL TMT 73 MTTrueTechnical Bid
All other documents should be as per tender documentTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksHaveriSavanuruDharwad NorthSHIGGAONSAVANURNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1726920972000
version0
createdDateNone
modifiedDateNone
blockNumberSecretary APMC Savanur Meeting Hall
streetNone
citySavanur
stateKarnataka
pin581118
tenderRecallDTONone