4046084 | 157019 | None | Code-01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 178.0 | False | None | None | False | None | False | 19063.8 | 0 |
4046085 | 157019 | None | Code-02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 112.0 | False | None | None | False | None | False | 31281.6 | 0 |
4046086 | 157019 | None | Code-03 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per Cum for every 1.50 m height or part there off | Cum | 497.7 | 497.7 | 5.0 | False | None | None | False | None | False | 2488.5 | 0 |
4046087 | 157019 | None | Code-04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse | Cum | 5947.2 | 5947.2 | 14.0 | False | None | None | False | None | False | 83260.8 | 0 |
4046088 | 157019 | None | Code-05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 2.0 | False | None | None | False | None | False | 13055.7 | 0 |
4046089 | 157019 | None | Code-06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 7.39 | False | None | None | False | None | False | 43538.5545 | 0 |
4046090 | 157019 | None | Code-07 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1375.5 | 1375.5 | 67.0 | False | None | None | False | None | False | 92158.5 | 0 |
4046091 | 157019 | None | Code-08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1159.2 | 1159.2 | 41.5 | False | None | None | False | None | False | 48106.8 | 0 |
4046092 | 157019 | None | Code-09 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 59.0 | False | None | None | False | None | False | 389479.65 | 0 |
4046093 | 157019 | None | Code-10 | Appendix-Additional form work, Centering & Scaffolding. Footings & Foundation-8% | Sqm | 528.1 | 528.1 | 31.554 | False | None | None | False | None | False | 16663.6674 | 0 |
4046094 | 157019 | None | Code-11 | Appendix-Additional form work, Centering & Scaffolding. Columns-70% | Sqm | 4620.94 | 4620.94 | 21.1248 | False | None | None | False | None | False | 97616.433312 | 0 |
4046095 | 157019 | None | Code-12 | Appendix-Additional form work, Centering & Scaffolding. Beams & Lintels of Building-60% | Sqm | 3960.81 | 3960.81 | 3.51 | False | None | None | False | None | False | 13902.4431 | 0 |
4046096 | 157019 | None | Code-13 | Appendix-Additional form work, Centering & Scaffolding. Roof (Straight & Arched)-20% | Sqm | 1320.27 | 1320.27 | 1.9495 | False | None | None | False | None | False | 2573.866365 | 0 |
4046097 | 157019 | None | Code-14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures | Tonne | 82961.55 | 82961.55 | 5.724 | False | None | None | False | None | False | 474871.9122 | 0 |
4046098 | 157019 | None | Code-15 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame | Mtr | 675.15 | 675.15 | 35.2 | False | None | None | False | None | False | 23765.28 | 0 |
4046099 | 157019 | None | Code-16 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood insideat required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. | Sqm | 3364.2 | 3364.2 | 10.5 | False | None | None | False | None | False | 35324.1 | 0 |
4046100 | 157019 | None | Code-17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling anddash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications | Kgs | 474.6 | 474.6 | 11.0 | False | None | None | False | None | False | 5220.6 | 0 |
4046101 | 157019 | None | Code-18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 176.4 | 176.4 | 23.0 | False | None | None | False | None | False | 4057.2 | 0 |
4046102 | 157019 | None | Code-19 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 4.0 | False | None | None | False | None | False | 11978.4 | 0 |
4046103 | 157019 | None | Code-20 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 9.0 | False | None | None | False | None | False | 10451.7 | 0 |
4046104 | 157019 | None | Code-21 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1521.45 | 1521.45 | 52.0 | False | None | None | False | None | False | 79115.4 | 0 |
4046105 | 157019 | None | Code-22 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding, including cost of materials, labour,curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 49.0 | False | None | None | False | None | False | 16618.35 | 0 |
4046106 | 157019 | None | Code-24 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 52.0 | False | None | None | False | None | False | 16107.0 | 0 |
4046107 | 157019 | None | Code-25 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 69.0 | False | None | None | False | None | False | 27893.25 | 0 |
4046108 | 157019 | None | Code-26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 49.0 | False | None | None | False | None | False | 5145.0 | 0 |
4046109 | 157019 | None | Code-27 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 115.5 | 115.5 | 49.0 | False | None | None | False | None | False | 5659.5 | 0 |
4046110 | 157019 | None | Code-28 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 186.9 | 186.9 | 69.0 | False | None | None | False | None | False | 12896.1 | 0 |
4046111 | 157019 | None | Code-29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 2.0 | False | None | None | False | None | False | 241.5 | 0 |
4046112 | 157019 | None | Code-30 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. | Each | 2462.25 | 2462.25 | 2.0 | False | None | None | False | None | False | 4924.5 | 0 |
4046113 | 157019 | None | Code-31 | Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | Each | 300.3 | 300.3 | 6.0 | False | None | None | False | None | False | 1801.8 | 0 |
4046114 | 157019 | None | Code-32 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. | Each | 7123.2 | 7123.2 | 1.0 | False | None | None | False | None | False | 7123.2 | 0 |
4046115 | 157019 | None | Code-33 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests. | Pan | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 |
4046116 | 157019 | None | Code-34 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore. | Each | 313.95 | 313.95 | 4.0 | False | None | None | False | None | False | 1255.8 | 0 |
4046117 | 157019 | None | Code-35 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | Mtr | 303.45 | 303.45 | 15.0 | False | None | None | False | None | False | 4551.75 | 0 |
4046118 | 157019 | None | Code-36 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | Mtr | 404.25 | 404.25 | 25.0 | False | None | None | False | None | False | 10106.25 | 0 |
4046119 | 157019 | None | Code-37 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipes | Mtr | 806.4 | 806.4 | 25.0 | False | None | None | False | None | False | 20160.0 | 0 |
4046120 | 157019 | None | Code-38 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Each | 2710.05 | 2710.05 | 4.0 | False | None | None | False | None | False | 10840.2 | 0 |
4046121 | 157019 | None | Code-39 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5. | No | 5924.1 | 5924.1 | 2.0 | False | None | None | False | None | False | 11848.2 | 0 |
4046122 | 157019 | None | Code-40 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | No | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 |
4046123 | 157019 | None | Code-41 | WATER SUPPLY SYSTEM
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 40.0 | False | None | None | False | None | False | 13356.0 | 0 |
4046124 | 157019 | None | Code-42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -32 mm nominal dia Pipes | Mtr | 420.0 | 420.0 | 20.0 | False | None | None | False | None | False | 8400.0 | 0 |
4046125 | 157019 | None | Code-43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -50 mm nominal dia Pipes | Mtr | 820.05 | 820.05 | 20.0 | False | None | None | False | None | False | 16401.0 | 0 |
4046126 | 157019 | None | Code-44 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore Horizontal | Each | 651.0 | 651.0 | 2.0 | False | None | None | False | None | False | 1302.0 | 0 |
4046127 | 157019 | None | Code-45 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore Vertical | Each | 971.25 | 971.25 | 2.0 | False | None | None | False | None | False | 1942.5 | 0 |
4046128 | 157019 | None | Code-46 | Providing and fixing unplasticised PVC connection pipe with brass unions. 45 cm length -20 mm nominal bore | Set | 115.5 | 115.5 | 4.0 | False | None | None | False | None | False | 462.0 | 0 |
4046129 | 157019 | None | Code-47 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(For 1000 litre capacity) | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
4046130 | 157019 | None | Code-48 | Bottom Frame 100mm X 50mm Specially formed M.S. C CHANNEL, Horizontal CrossMember100mm X 50mm Specially formed M.S. C CHANNEL, Vertical Cross Member.2 Top Frame 50mm X 50mm Specially Formed M.S Square Pipe.3 Stiffener Bottom 100 x 50 mm ISMBC CHANNEL. 4 Stiffener Top 40 x 20 M.S. Sq. Pipe.5 Side Post 65mm x 65mm MS Sq. Pipe .6 Panelling Outside Specially GI Sheet MS CR make jsw, eassar,asian,tata,).7 Internal Wall Panelling 8mm mdf board 1year warranty.8 Roof Outside G I Sheet MS CR (make jsw, eassar, asian, Tata,)thick Properly Sloped and water tight.9 False Ceiling 8mm mdf board 1year warranty).10 Bottom Flooring 18mm Cement Fiber Board with Vinyl Carpet MAKE V BOARD,EVAREST BOARD,SHYADRI BOARD.11 Door Door with MS Structure 40x20 sq pipe composite panel Finish WITH for locking agreement, Hold draft & Handles.12 Insulation Glass Wool density of 16kg per cum Side Wall 25mm .13 Wiring All wiring shall be concealed type & shall be of PVC insulated copper wire.MAKE polycab,HAVELLS)HEAT RESISTANT FLAME RETARDANT.14 Electrical Fittings All electrical fittings in the Portable Cabin shall be 220 240 V, AC 50Hz led light (make :Philips HAVELLS) , Door Light , Fan, Switches, Sockets, Telephone, Air Conditioners Point (MCB) (All Type of Window Air Conditioning Systems as desired upon can be installed.(anchor romaHAVELLS switch & sockets.15 Ear thing Earthling Point shall be provided for SAFETY.16 Outside Painting Phosphate the Cabin and painting with 1coat of Epoxy primer with Two Coat of Epoxy Paint.17 Legs 6inch height, Four legs at all four corners.18 Hooks Specially formed Hooks for Easy lifting and Shifting. | Each | 150000.0 | 150000.0 | 19.0 | False | None | None | False | None | False | 2850000.0 | 0 |
4046131 | 157019 | None | Code-49 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifi cations suitable to withstand the wind speed of 47 m/s for ..... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom .... mm , top mm with 3 mm thick, suitable base plate and 4Nos of......long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 4 m - Top 75 mm and Bottom 115 mm dia | Each | 8925.0 | 8925.0 | 32.0 | False | None | None | False | None | False | 285600.0 | 0 |
4046132 | 157019 | None | Code-50 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary
bolts, nuts etc., complete.
Single Arm Bracket with 1000 mm Standard 40/50 mm dia | Each | 1785.0 | 1785.0 | 32.0 | False | None | None | False | None | False | 57120.0 | 0 |
4046133 | 157019 | None | Code-51 | Single Arm Bracket with 1500 mm Standard 40/50 mm dia | Each | 2205.0 | 2205.0 | 8.0 | False | None | None | False | None | False | 17640.0 | 0 |
4046134 | 157019 | None | Code-52 | LED Flood Light.
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 90012008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 100W | Each | 9960.3 | 9960.3 | 8.0 | False | None | None | False | None | False | 79682.4 | 0 |
4046135 | 157019 | None | Code-53 | LED Street light.
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70W | Each | 6291.6 | 6291.6 | 32.0 | False | None | None | False | None | False | 201331.2 | 0 |
4046136 | 157019 | None | Code-54 | Open Conduit System
Open Conduit System , Supplying heavy gauge PVC conduit pipe ... dia .... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
19/20 mm dia 2 mm thick | m | 72.45 | 72.45 | 50.0 | False | None | None | False | None | False | 3622.5 | 0 |
4046137 | 157019 | None | Code-55 | Open Conduit System
Open Conduit System , Supplying heavy gauge PVC conduit pipe ... dia .... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
25 mm dia 2 mm thick | m | 85.05 | 85.05 | 50.0 | False | None | None | False | None | False | 4252.5 | 0 |
4046138 | 157019 | None | Code-56 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing cappin gusing 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRL Smultistr and PVC insulated copper wire (confirmingtoIS- 694: and late stamendments) without switches all befixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3M trup to 6M tr from tapping point to outlet via switch box | Point | 397.95 | 397.95 | 4.0 | False | None | None | False | None | False | 1591.8 | 0 |
4046139 | 157019 | None | Code-57 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire(confirmingtoIS- 694: and latest amendments) without switches shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto10 Mtr from tapping point to outlet via switch box | Point | 582.75 | 582.75 | 4.0 | False | None | None | False | None | False | 2331.0 | 0 |
4046140 | 157019 | None | Code-58 | supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 10-12way | Each | 334.95 | 334.95 | 2.0 | False | None | None | False | None | False | 669.9 | 0 |
4046141 | 157019 | None | Code-59 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.10-12 module | Each | 361.2 | 361.2 | 2.0 | False | None | None | False | None | False | 722.4 | 0 |
4046142 | 157019 | None | Code-60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch | Each | 107.1 | 107.1 | 10.0 | False | None | None | False | None | False | 1071.0 | 0 |
4046143 | 157019 | None | Code-61 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 179.55 | 179.55 | 2.0 | False | None | None | False | None | False | 359.1 | 0 |
4046144 | 157019 | None | Code-62 | Wiring for lighting /Popwer Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694:2010 . 1.5 sqmm | Mtr | 27.3 | 27.3 | 50.0 | False | None | None | False | None | False | 1365.0 | 0 |
4046145 | 157019 | None | Code-63 | Wiring for lighting /Popwer Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 :2010, . 2.5 Sqmm. | Mtr | 44.1 | 44.1 | 100.0 | False | None | None | False | None | False | 4410.0 | 0 |
4046146 | 157019 | None | Code-64 | Wiring for lighting /Popwer Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 :2010 . 4 Sqmm. | Mtr | 66.15 | 66.15 | 50.0 | False | None | None | False | None | False | 3307.5 | 0 |
4046147 | 157019 | None | Code-65 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Batten Holder | Each | 77.7 | 77.7 | 8.0 | False | None | None | False | None | False | 621.6 | 0 |
4046148 | 157019 | None | Code-66 | Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. | Each | 884.1 | 884.1 | 1.0 | False | None | None | False | None | False | 884.1 | 0 |
4046149 | 157019 | None | Code-67 | Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any
manufacturing defect working under standard electrical condition. 12W 6500K | No | 282.45 | 282.45 | 7.0 | False | None | None | False | None | False | 1977.15 | 0 |
4046150 | 157019 | None | Code-68 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP | Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 |
4046151 | 157019 | None | Code-69 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.4Way SP &N Double Door | Each | 1600.2 | 1600.2 | 2.0 | False | None | None | False | None | False | 3200.4 | 0 |
4046152 | 157019 | None | Code-70 | Supplying, fixingand wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole | Each | 4490.85 | 4490.85 | 2.0 | False | None | None | False | None | False | 8981.7 | 0 |
4046153 | 157019 | None | Code-71 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload & Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insula tion between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole 100 A 25 kA | Each | 8911.35 | 8911.35 | 1.0 | False | None | None | False | None | False | 8911.35 | 0 |
4046154 | 157019 | None | Code-72 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.(48/6.36) | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 |
4046155 | 157019 | None | Code-73 | Supplying ...... amps rated 3 phase with neutral bus bar using required capacity electrolytic allumimium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. -250Amps 4x30x10mm Aluminium Strips | Mtr | 3606.75 | 3606.75 | 2.0 | False | None | None | False | None | False | 7213.5 | 0 |
4046156 | 157019 | None | Code-74 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tank streatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG | Sqm | 0.45 | 0.45 | 22500.0 | False | None | None | False | None | False | 10125.0 | 0 |
4046157 | 157019 | None | Code-75 | Supplying and Fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc, and fixing on existing wood or metal box using N.F screws. | Sqm | 0.36 | 0.36 | 1200.0 | False | None | None | False | None | False | 432.0 | 0 |
4046158 | 157019 | None | Code-76 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG set setc. using 40 mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixedon the top of the earth electrode. The funnel should been closed in a CC chamber of 400x400x400 mm with acastironc over. The earth electrode shall have stag geredholes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4468.8 | 4468.8 | 2.0 | False | None | None | False | None | False | 8937.6 | 0 |
4046159 | 157019 | None | Code-77 | GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required. 25 x 6 mm GI strip | Mtr | 134.4 | 134.4 | 20.0 | False | None | None | False | None | False | 2688.0 | 0 |
4046160 | 157019 | None | Code-78 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor. | Kvar | 504.0 | 504.0 | 5.0 | False | None | None | False | None | False | 2520.0 | 0 |
4046161 | 157019 | None | Code-79 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy
Meter. | Each | 5990.25 | 5990.25 | 1.0 | False | None | None | False | None | False | 5990.25 | 0 |
4046162 | 157019 | None | Code-80 | Supply and fixingpolished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the walll using tapered inverted wooden plugs screws. 20"x20"2.5" | Each | 342.43 | 342.43 | 2.0 | False | None | None | False | None | False | 684.86 | 0 |
4046163 | 157019 | None | Code-81 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe:Heavy Duty GI pipe of 50mm dia
Cable laying on pole side &road crossing | m | 573.3 | 573.3 | 30.0 | False | None | None | False | None | False | 17199.0 | 0 |
4046164 | 157019 | None | Code-82 | Pole mounted fibre glass reinforced aerial fuse board 60 Amps - 3way Way(Dwg No. BESCOM/GM/QS&S/24 Dtd 24.11.2018) | Each | 1008.0 | 1008.0 | 1.0 | False | None | None | False | None | False | 1008.0 | 0 |
4046165 | 157019 | None | Code-83 | Fixing Pole Fuse Board | No | 149.1 | 149.1 | 1.0 | False | None | None | False | None | False | 149.1 | 0 |
4046166 | 157019 | None | Code-84 | FOR POLES
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 148934.1 | 148934.1 | 0.6 | False | None | None | False | None | False | 89360.46 | 0 |
4046167 | 157019 | None | Code-85 | FOR POLES
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff. 2.5 to 25 Sqmm | Km | 21930.3 | 21930.3 | 0.6 | False | None | None | False | None | False | 13158.18 | 0 |
4046168 | 157019 | None | Code-86 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, Up to 4C x 50 Sqmm | Each | 340.2 | 340.2 | 1.0 | False | None | None | False | None | False | 340.2 | 0 |
4046169 | 157019 | None | Code-87 | For earth pits
Guy Wire & GI Wire as per IS-2141, 8 SWG GI Wire(4.064 mm Dia), Std Wt: 131 Kg/KM | Kg | 78.79 | 78.79 | 13.1 | False | None | None | False | None | False | 1032.149 | 0 |
4046170 | 157019 | None | Code-88 | Supplying and fixing Aluminium End Terminal (Lug) suitable for 1.1 kV, LTUG Cable filled with necessary bituumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc - 25 Sqmm | Nos | 2.1 | 2.1 | 300.0 | False | None | None | False | None | False | 630.0 | 0 |
4046171 | 157019 | None | Code-89 | Caution/Danger Board | Each | 333.9 | 333.9 | 1.0 | False | None | None | False | None | False | 333.9 | 0 |
4046172 | 157019 | None | Code-90 | Fixing Danger Board | Unit | 84.0 | 84.0 | 1.0 | False | None | None | False | None | False | 84.0 | 0 |
4046173 | 157019 | None | Code-91 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m ncluding cost of labour, tools, usage& other appurtenances required o complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 262.5 | False | None | None | False | None | False | 133402.5 | 0 |
4046174 | 157019 | None | Code-92 | Spiral Earth Electrode | No | 250.95 | 250.95 | 44.0 | False | None | None | False | None | False | 11041.8 | 0 |
4046175 | 157019 | None | Code-93 | Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,) | No | 97.65 | 97.65 | 50.0 | False | None | None | False | None | False | 4882.5 | 0 |
4046176 | 157019 | None | Code-94 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 2.5 mm2 | m | 118.65 | 118.65 | 350.0 | False | None | None | False | None | False | 41527.5 | 0 |
4046177 | 157019 | None | Code-95 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 170.1 | 170.1 | 12.0 | False | None | None | False | None | False | 2041.2 | 0 |
4046178 | 157019 | None | Code-96 | Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires. | Each | 207.9 | 207.9 | 32.0 | False | None | None | False | None | False | 6652.8 | 0 |
4046179 | 157019 | None | Code-97 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifi cations suitable to withstand the wind speed of 47 m/s for ..... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom .... mm , top mm with 3 mm thick, suitable base plate and 4Nos of......long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended.
8 m - Top 75 mm and Bottom 155 mm dia | Each | 18795.0 | 18795.0 | 12.0 | False | None | None | False | None | False | 225540.0 | 0 |
4046180 | 157019 | None | Code-98 | LED Floodlight 100W
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 9960.3 | 9960.3 | 12.0 | False | None | None | False | None | False | 119523.6 | 0 |
4046181 | 157019 | None | Code-99 | Single Arm Bracket with 1500 mm Standard 40/50 mm dia | Each | 2205.0 | 2205.0 | 12.0 | False | None | None | False | None | False | 26460.0 | 0 |