createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726916454925
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1610.00
emd109100.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-10-2024 17:30:00
tenderQueryClose07-10-2024 11:00:00
technicalBidOpen10-10-2024 11:00:00
publishedDate21-09-2024 16:52:11
publishedByPostRDPR_EE_DIV_VJP
publishedByUserKPE13083 - NABILAL M GABASAVALGI
bidValidityPeriod90
noOfCalls1
preBidMeetingDate07-10-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonR R Rajaput JE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9538547624
tenderSupplierListNone
tenderSchedule
createdTs1726916454966
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8877
titlePackage-1 - (1) Construction of Science Lab to Govt High School in Talikoti Town of Vijayapur Dist (2) Repairs to Model Higher Primary School in Talikoti Town o0f Vijayapur Dist (H/Ac 4202 Mahatwakanshi Yojane 2023-24)
descriptionPackage-1 - (1) Construction of Science Lab to Govt High School in Talikoti Town of Vijayapur Dist (2) Repairs to Model Higher Primary School in Talikoti Town o0f Vijayapur Dist (H/Ac 4202 Mahatwakanshi Yojane 2023-24)
categoryWORKS
categoryTextWorks
ecv6432438.68
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location803
locationNameRDPR Division Office Vijayapura
provisionalAmount6548000.0
groupOverheadTotal981219.46
fileNumberScience-Lab-and-MPS-Talikoti
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17269164550000NoneNoneBuildingsConstruction of Ground Floor1520023.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4048359157157Nonecode01Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum242.0242.049.52FalseNoneNoneFalseNoneFalse11983.840
4048360157157Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5664.05664.016.96FalseNoneNoneFalseNoneFalse96061.440
4048361157157Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6287.06287.09.18FalseNoneNoneFalseNoneFalse57714.660
4048362157157Nonecode04For Additionalities for Formwork,Centring & Scaffolding for columns footingsCum502.96502.965.91FalseNoneNoneFalseNoneFalse2972.49360
4048363157157Nonecode05For Additionalities for Formwork,Centring & Scaffolding for Plinth BeamCum3143.53143.53.27FalseNoneNoneFalseNoneFalse10279.2450
4048364157157Nonecode06Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5611.05611.043.12FalseNoneNoneFalseNoneFalse241946.320
4048365157157Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6630.06630.019.83FalseNoneNoneFalseNoneFalse131472.90
4048366157157Nonecode08For Additionalities for Formwork,Centring & Scaffolding for ColumnsCum4641.04641.04.62FalseNoneNoneFalseNoneFalse21441.420
4048367157157Nonecode09For Additionalities for Formwork,Centring & Scaffolding for lintelsCum3978.03978.01.22FalseNoneNoneFalseNoneFalse4853.160
4048368157157Nonecode10For Additionalities for Formwork,Centring & Scaffolding for ChajjaaCum2983.52983.50.19FalseNoneNoneFalseNoneFalse566.8650
4048369157157Nonecode11For Additionalities for Formwork,Centring & Scaffolding for Roof BeamCum3978.03978.04.18FalseNoneNoneFalseNoneFalse16628.040
4048370157157Nonecode12For Additionalities for Formwork,Centring & Scaffolding for SlabCum3315.03315.09.62FalseNoneNoneFalseNoneFalse31890.30
4048371157157Nonecode13Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift upto 1.5 m.Cum433.0433.073.8FalseNoneNoneFalseNoneFalse31955.40
4048372157157Nonecode14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8211.08211.018.49FalseNoneNoneFalseNoneFalse151821.390
4048373157157Nonecode15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) mix 1:3:6 ( M 10) Using 20 mm nominal size graded crushed coarse aggregatesCum6217.06217.01.08FalseNoneNoneFalseNoneFalse6714.360
4048374157157Nonecode16Providing Jungle wood such as Nerale, Neem wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications.Cum44929.044929.00.226FalseNoneNoneFalseNoneFalse10153.9540
4048375157157Nonecode17Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNo1016.01016.01.0FalseNoneNoneFalseNoneFalse1016.00
4048376157157Nonecode18Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNo773.0773.04.0FalseNoneNoneFalseNoneFalse3092.00
4048377157157Nonecode19Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm6576.06576.02.52FalseNoneNoneFalseNoneFalse16571.520
4048378157157Nonecode20Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7013.07013.07.2FalseNoneNoneFalseNoneFalse50493.60
4048379157157Nonecode21Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mmNo55.055.032.0FalseNoneNoneFalseNoneFalse1760.00
4048380157157Nonecode22Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.No60.060.024.0FalseNoneNoneFalseNoneFalse1440.00
4048381157157Nonecode23Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg168.0168.0151.2FalseNoneNoneFalseNoneFalse25401.60
4048382157157Nonecode24Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne89457.089457.02.49FalseNoneNoneFalseNoneFalse222747.930
4048383157157Nonecode25Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm354.0354.045.38FalseNoneNoneFalseNoneFalse16064.520
4048384157157Nonecode26Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.0349.0358.22FalseNoneNoneFalseNoneFalse125018.780
4048385157157Nonecode27Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm312.0312.062.19FalseNoneNoneFalseNoneFalse19403.280
4048386157157Nonecode28Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm100.0100.0162.5FalseNoneNoneFalseNoneFalse16250.00
4048387157157Nonecode29Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge.Sqm138.0138.085.05FalseNoneNoneFalseNoneFalse11736.90
4048388157157Nonecode30Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1545.01545.070.88FalseNoneNoneFalseNoneFalse109509.60
4048389157157Nonecode31Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conferming to IS :13592 type A Including Jointing with seal ring conferming to IS 5382 leaving to 10 mm gap for thermal expansion (i)Single socketed pipes 75 mm daimeterMtr197.0197.015.0FalseNoneNoneFalseNoneFalse2955.00
4048390157157Nonecode32Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm137.0137.0188.37FalseNoneNoneFalseNoneFalse25806.690
4048391157157Nonecode33Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., including cost of materials, labour, HOM complete as per specifications.No772.0772.02.0FalseNoneNoneFalseNoneFalse1544.00
4048392157157Nonecode34Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm178.0178.0205.5FalseNoneNoneFalseNoneFalse36579.00
4048393157157Nonecode35Applying priming coat: With ready mixed pink or Grey primer ofapproved brand and manufacture on wood work (hard and soft wood)including preparing the surface after thorougly cleaning oil, grease,dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge.Sqm53.053.021.87FalseNoneNoneFalseNoneFalse1159.110
4048394157157Nonecode36Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm138.0138.021.87FalseNoneNoneFalseNoneFalse3018.060
17269164550000NoneNoneBuildingsElectrification to Building47943.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4048395157158Nonecode01Suppling heavy gauge P V C Conduit pipe …. Mm dai … mm thick Confireming to I S 2509 with suitable size bends P V C Junction boxes ETC and running before concreting slab the conduite shouldbe tide to the reinforcement rod by using binding wires and pipe ends should be covered using P V C end enclosures run with 18 SWG GI fish wire wherever necessary . 19/20mmdai 2mm thick For 10 roomsMtr69.069.070.0FalseNoneNoneFalseNoneFalse4830.00
4048396157158Nonecode02Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxPoint285.0285.08.0FalseNoneNoneFalseNoneFalse2280.00
4048397157158Nonecode03do- Short point Up to 3Mt from tapping point to out let via switch boxPoint394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
4048398157158Nonecode04Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.Mtr29.029.030.0FalseNoneNoneFalseNoneFalse870.00
4048399157158Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5sqmmMtr26.026.0160.0FalseNoneNoneFalseNoneFalse4160.00
4048400157158Nonecode06Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way . complete as per direction of engineer in charge.Mtr42.042.0170.0FalseNoneNoneFalseNoneFalse7140.00
4048401157158Nonecode07Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way . complete as per direction of engineer in charge. 4-5 wayNo137.0137.04.0FalseNoneNoneFalseNoneFalse548.00
4048402157158Nonecode08Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6-8Way . complete as per direction of engineer in charge. 8 wayNo219.0219.02.0FalseNoneNoneFalseNoneFalse438.00
4048403157158Nonecode09Supplying and fixing of modular Stepped Fan Regulator.No357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
4048404157158Nonecode10Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing systemNo2984.02984.04.0FalseNoneNoneFalseNoneFalse11936.00
4048405157158Nonecode11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wiredNo150.0150.04.0FalseNoneNoneFalseNoneFalse600.00
4048406157158Nonecode12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293 6 Amps 3 way SocketNo171.0171.012.0FalseNoneNoneFalseNoneFalse2052.00
4048407157158Nonecode13Supplying and fixing of 400 Watts DimmerNo276.0276.02.0FalseNoneNoneFalseNoneFalse552.00
4048408157158Nonecode14Supplying and fixing of 32 Ams D P SwitchNo326.0326.02.0FalseNoneNoneFalseNoneFalse652.00
4048409157158Nonecode15Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WNo551.0551.06.0FalseNoneNoneFalseNoneFalse3306.00
4048410157158Nonecode16do- LED light fitting 1 x 4' - 20/22 WNo690.0690.02.0FalseNoneNoneFalseNoneFalse1380.00
4048411157158Nonecode17Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6-32 A DPNo1241.01241.01.0FalseNoneNoneFalseNoneFalse1241.00
4048412157158Nonecode18Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo2999.72999.71.0FalseNoneNoneFalseNoneFalse2999.70
4048413157158Nonecode19Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.12 SWG GI WireNo14.014.01.0FalseNoneNoneFalseNoneFalse14.00
4048414157158Nonecode20Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.40mmMtr335.0335.01.0FalseNoneNoneFalseNoneFalse335.00
17269164550000NoneNoneBuildingsRepair Estimate MPS Talikoti3655822.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4048415157159Nonecode01Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-chargeCum1684.01684.014.85FalseNoneNoneFalseNoneFalse25007.40
4048416157159Nonecode02Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2426.02426.046.2FalseNoneNoneFalseNoneFalse112081.20
4048417157159Nonecode03Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the workCum177.0177.08.91FalseNoneNoneFalseNoneFalse1577.070
4048418157159Nonecode04Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6323.06323.00.32FalseNoneNoneFalseNoneFalse2023.360
4048419157159Nonecode05Appendix I Additionalities for Formwork, Centering - 12. Columns of Building - 70%Cum4426.14426.10.32FalseNoneNoneFalseNoneFalse1416.3520
4048420157159Nonecode06Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6389.06389.056.67FalseNoneNoneFalseNoneFalse362064.630
4048421157159Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6630.06630.046.19FalseNoneNoneFalseNoneFalse306239.70
4048422157159Nonecode08Appendix I Additionalities for Formwork, Centering - 12. Beams & Lintels of Building - 60%Cum3978.03978.07.72FalseNoneNoneFalseNoneFalse30710.160
4048423157159Nonecode09Appendix I Additionalities for Formwork, Centering - 12. Roof of Building - 50%Cum3315.03315.038.46FalseNoneNoneFalseNoneFalse127494.90
4048424157159Nonecode10Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete asper drawing and technical specificationKg89.4589.453273.51FalseNoneNoneFalseNoneFalse292815.46950
4048425157159Nonecode11Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm241.0241.0197.7FalseNoneNoneFalseNoneFalse47645.70
4048426157159Nonecode12Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm354.0354.0228.6FalseNoneNoneFalseNoneFalse80924.40
4048427157159Nonecode13Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum433.0433.059.31FalseNoneNoneFalseNoneFalse25681.230
4048428157159Nonecode14Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5664.05664.026.79FalseNoneNoneFalseNoneFalse151738.560
4048429157159Nonecode15Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1545.01545.0364.37FalseNoneNoneFalseNoneFalse562951.650
4048430157159Nonecode16Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm137.0137.01728.13FalseNoneNoneFalseNoneFalse236753.810
4048431157159Nonecode17Finishing walls with textured exterior paint of required shade :Old work (Two coats on existing cement paint surface applied @ 3.28 l/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter,Sqm216.0216.0241.2FalseNoneNoneFalseNoneFalse52099.20
4048432157159Nonecode18Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum124202.0124202.01.26FalseNoneNoneFalseNoneFalse156494.520
4048433157159Nonecode19Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1016.01016.05.0FalseNoneNoneFalseNoneFalse5080.00
4048434157159Nonecode20Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNo773.0773.05.0FalseNoneNoneFalseNoneFalse3865.00
4048435157159Nonecode21Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7444.07444.012.6FalseNoneNoneFalseNoneFalse93794.40
4048436157159Nonecode22Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7574.07574.018.9FalseNoneNoneFalseNoneFalse143148.60
4048437157159Nonecode23Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mmNo55.055.0120.0FalseNoneNoneFalseNoneFalse6600.00
4048438157159Nonecode24Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.No60.060.0120.0FalseNoneNoneFalseNoneFalse7200.00
4048439157159Nonecode25Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm115.0115.0225.38FalseNoneNoneFalseNoneFalse25918.70
4048440157159Nonecode26Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.Sqm50.050.0399.3FalseNoneNoneFalseNoneFalse19965.00
4048441157159Nonecode27Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace /Chajjas /Sunken portion of WC:Bathroom, cold applied PU wa terproofingmembrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm817.0817.0693.0FalseNoneNoneFalseNoneFalse566181.00
4048442157159Nonecode28Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum2559.02559.011.55FalseNoneNoneFalseNoneFalse29556.450
4048443157159Nonecode29Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification).Sqm1161.01161.0154.0FalseNoneNoneFalseNoneFalse178794.00
17269164550000NoneNoneBuildingsElectrification to MPS Building227429.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4048444157160Nonecode01Suppling heavy gauge P V C Conduit pipe …. Mm dai … mm thick Confireming to I S 2509 with suitable size bends P V C Junction boxes ETC and running before concreting slab the conduite shouldbe tide to the reinforcement rod by using binding wires and pipe ends should be covered using P V C end enclosures run with 18 SWG GI fish wire wherever necessary . 19/20mmdai 2mm thick For 10 roomsMtr69.069.0300.0FalseNoneNoneFalseNoneFalse20700.00
4048445157160Nonecode02Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxPoint285.0285.060.0FalseNoneNoneFalseNoneFalse17100.00
4048446157160Nonecode03do- Short point Up to 3Mt from tapping point to out let via switch boxPoint394.0394.030.0FalseNoneNoneFalseNoneFalse11820.00
4048447157160Nonecode04Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.Mtr29.029.0300.0FalseNoneNoneFalseNoneFalse8700.00
4048448157160Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5sqmmMtr26.026.0800.0FalseNoneNoneFalseNoneFalse20800.00
4048449157160Nonecode06Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way . complete as per direction of engineer in charge. 4-5 wayNo137.0137.060.0FalseNoneNoneFalseNoneFalse8220.00
4048450157160Nonecode07Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6-8Way . complete as per direction of engineer in charge. 8 wayNo219.0219.020.0FalseNoneNoneFalseNoneFalse4380.00
4048451157160Nonecode08Supplying and fixing of modular Stepped Fan Regulator.No357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
4048452157160Nonecode09Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing systemNo2984.02984.020.0FalseNoneNoneFalseNoneFalse59680.00
4048453157160Nonecode10Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wiredNo150.0150.020.0FalseNoneNoneFalseNoneFalse3000.00
4048454157160Nonecode11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293 6 Amps 3 way SocketNo171.0171.0120.0FalseNoneNoneFalseNoneFalse20520.00
4048455157160Nonecode12Supplying and fixing of 400 Watts DimmerNo276.0276.020.0FalseNoneNoneFalseNoneFalse5520.00
4048456157160Nonecode13Supplying and fixing of 32 Ams D P SwitchNo326.0326.020.0FalseNoneNoneFalseNoneFalse6520.00
4048457157160Nonecode14Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WNo551.0551.020.0FalseNoneNoneFalseNoneFalse11020.00
4048458157160Nonecode15do- LED light fitting 1 x 4' - 20/22 WNo690.0690.010.0FalseNoneNoneFalseNoneFalse6900.00
4048459157160Nonecode16Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6-32 A DPNo1241.01241.010.0FalseNoneNoneFalseNoneFalse12410.00
4048460157160Nonecode17Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo2999.72999.71.0FalseNoneNoneFalseNoneFalse2999.70
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17269164560000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17269164560000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17269164560000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17269164560000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17269164560000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17269166120000NoneNoneELIGIBILITYTo qualify for award of this contract each tenderer in his name should have in the last five years period (i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24) Turnover Certificate obtained from Charted Accountant and achieved in at least two financial years an average Annual Financial Turnover (in all classes of civil Engineering construction works only) of Rs. 54.51 lakhs (usually not less than the estimated cost under this contractNone
17269166210000NoneNoneELIGIBILITYIn last five years (i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24) Satisfactorily completed as a prime contractor for at least one similar nature of work done 50% of the cost of the work i.e., not less than the amount Rs 27.26 lakhs, certificate issued from the rank of Executive Engineer and above for the same should be furnished by the contractor. (With Work Indent Number).None
17269166240000NoneNoneELIGIBILITYLiquid assets and /or availability of credit facilities of not less than Rs 16.35 lakhs (30% of amount put to tender) (Credit lines/ letter of credit/ certificates from Nationalized banks for meeting the fund requirement etc.) for particularly this work only. (Unconditional) in given formatNone
17269166360000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years Executed in any one year, the following minimum 80 % quantities of work in last five years. 1. Earth Work Exavation - 46.74 Cum 2. RCC/PCC - 98.68 Cum 3. UCR - 91.71 Cum 4. BBM - 14.79 Cum 5. Steel - 4.61 Tonne 6. Plaster - 713.67 Sqm 7. Flooring - 348.20 SqmNone
17269166450000NoneNoneELIGIBILITYEMD may be paid fully by E-payment Rs. 1,09,100/-None
17269166580000NoneNoneELIGIBILITYContractor should obey with the above conditions in addition to the KW-3None
17269166630000NoneNoneELIGIBILITYContractor should upload KPWD renewal registration copy.None
17269166670000NoneNoneELIGIBILITYThe contractor should scan the GST Certificate, PAN card & Contact Phone No, Postal Address DetailsNone
17269166700000NoneNoneELIGIBILITYPeriod of completion 3 Months including MonsoonNone
17269166740000NoneNoneELIGIBILITYCalculation sheet of Bidder Capacity AxNX2.50-BNone
17269166800000NoneNoneELIGIBILITYIn case the contractor participating in the tender submits a lower rate, the difference amount shall be paid in advance as security deposit in any nationalized bank and the relevant document shall be uploaded, in case not uploaded, which such tender proposal shall be rejected.None
17269166830000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17269166860000NoneNoneELIGIBILITYPWD Registration Certificate Class I and AboveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in his name should have in the last five years period (i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24) Turnover Certificate obtained from Charted Accountant and achieved in at least two financial years an average Annual Financial Turnover (in all classes of civil Engineering construction works only) of Rs. 54.51 lakhs (usually not less than the estimated cost under this contractCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneIn last five years (i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24) Satisfactorily completed as a prime contractor for at least one similar nature of work done 50% of the cost of the work i.e., not less than the amount Rs 27.26 lakhs, certificate issued from the rank of Executive Engineer and above for the same should be furnished by the contractor. (With Work Indent Number).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of not less than Rs 16.35 lakhs (30% of amount put to tender) (Credit lines/ letter of credit/ certificates from Nationalized banks for meeting the fund requirement etc.) for particularly this work only. (Unconditional) in given formatCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years Executed in any one year, the following minimum 80 % quantities of work in last five years. 1. Earth Work Exavation - 46.74 Cum 2. RCC/PCC - 98.68 Cum 3. UCR - 91.71 Cum 4. BBM - 14.79 Cum 5. Steel - 4.61 Tonne 6. Plaster - 713.67 Sqm 7. Flooring - 348.20 SqmCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneEMD may be paid fully by E-payment Rs. 1,09,100/-Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EMD
NoneNoneNoneNoneThe contractor should scan the GST Certificate, PAN card & Contact Phone No, Postal Address DetailsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN Adhar and GST
NoneNoneNoneNoneCalculation sheet of Bidder Capacity AxNX2.50-BCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bidder Capacity
NoneNoneNoneNoneIn case the contractor participating in the tender submits a lower rate, the difference amount shall be paid in advance as security deposit in any nationalized bank and the relevant document shall be uploaded, in case not uploaded, which such tender proposal shall be rejected.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Difference Amount in FDR or DD
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD CLASS-1 and Above Registration CertificationTrueTechnical Bid
Tendere Must Submnit PAN & GST CertificateTrueTechnical Bid
Tenderer must have of value 2019-20, 2020-21, 2021-22, 2022-23 to 2023-24 satisfactory completed as a prime contractor at least one similar nature of Work of 50PERCENT of the Amount Put to Tender Percent of nor less than Rs 27.26 lakhs issued by the officer not below tha rank of Executive Engineer for Similer Single nature of Works Work Done certificate with works should be produced Work Done with Indent No.TrueTechnical Bid
Work Order / Commitments of ongoing works issued by an officer not below the rank of Executive EngineerTrueTechnical Bid
To quality for award of this contant each tenderer in his name should have in the 2019-20 to 2023-24 years period achieved in at least two financial years an average finance turnover of Rs 54.51 lakhs usually not less than amount put to tender from CA on letter Head with UDIN No otherwise bid will be directly disqualifiedTrueTechnical Bid
Accurate postal address and Phone / cell NumberTrueTechnical Bid
Tender who meet the above specified minimum qualifying will only be qualified if there available tender capacity is more than the total tinder value the web available tender capacity will be calculated as under associated available tender capacity A X N X 2.50 - BTrueTechnical Bid
Contractor should submit the difference amount as per the CSR 2023 24 and it is to be handed over to the EE PRE Division Office Vijayapur after issuing the LOITrueTechnical Bid
LIQUID ASSETS AND OR AVAILABILITY OF CREDIT FACILITIES OF NOT LESS THAN 30 PERCENT OF THE AMOUNT OF CONTRACT THE VALUE SHOULD NOT LESS THAN RS 16.35 LAKHSTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1726917290000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive Engineer PRE Division ZP Campus VIJAYAPUR
streetNone
cityVIJAYAPUR
stateKarnataka
pin586101
tenderRecallDTONone