createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726228457411
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4050.00
emd206000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-10-2024 17:30:00
tenderQueryClose27-09-2024 17:30:00
technicalBidOpen14-10-2024 11:00:00
publishedDate23-09-2024 13:13:21
publishedByPostDUDC_EE_SMG
publishedByUserKPE11254 - NADAF VAHIDA BEGUM
bidValidityPeriod90
noOfCalls1
preBidMeetingDate27-09-2024 17:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonLingaraju AEE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08182226868
mobileNumber9916541515
tenderSupplierListNone
tenderSchedule
createdTs1726228457457
version20
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT20416
titleConstruction of Building and other works for the urban local Body TMC Shiralkoppa Limits under Amrutha Nagarothana (Municipality) Phase-4 Project.
descriptionConstruction of Building and other works for the urban local Body TMC Shiralkoppa Limits under Amrutha Nagarothana (Municipality) Phase-4 Project.
categoryWORKS
categoryTextWorks
ecv16173146.27
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2202
locationNameDMA District Urban Development Cell Shivamogga
provisionalAmount16229000.0
groupOverheadTotal2467090.11
fileNumberSMGDC-DUDC/PLAN/91934/2022
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17262284570000NoneNoneBuildingsConstruction of Building and other works for the urban local Body TMC Shiralkoppa Limits under Amrutha Nagarothana (Municipality) Phase-4 Project. (other work )13706056.16
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4002663154892NoneSR-2021-22 Vol 2 Page No 163 Item No. 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.: In cement mortarCum812.67812.6759.52FalseNoneNoneFalseNoneFalse48370.11840
4002664154892NoneSR-2021-22 Vol. 2 Page No. 166 Item No. 19.30Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Sqm112.27112.27247.0FalseNoneNoneFalseNoneFalse27730.690
4002665154892NoneSR-2021-22 Vol. 2 Page No. 164 - Item No. 19.12.2Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge.Sqm207.03207.0355.08FalseNoneNoneFalseNoneFalse11403.21240
4002666154892NoneSR-2021-22 - Vol. 1 - Page No. 8 - Item No. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum66.9566.9542.58FalseNoneNoneFalseNoneFalse2850.7310
4002667154892NoneSR-2021-22 Vol. 1 Page No. 8 Item No. 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In ordinary/soft rock without blasting upto 1.5 m depthCum280.16280.16208.63FalseNoneNoneFalseNoneFalse58449.78080
4002668154892NoneSR-2021-22 Vol. 1 Page No. 8 Item No. 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5512.565512.56259.49FalseNoneNoneFalseNoneFalse1430454.19440
4002669154892NoneSR-2021-22 Vol. 1 Page No. 15 Item No. 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Cum5720.625720.6239.342FalseNoneNoneFalseNoneFalse225060.632040
4002670154892NoneSR-2021-22 Vol. 1 Page No. 15 Item No. 2.2.1.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6610.996610.9949.664FalseNoneNoneFalseNoneFalse328328.207360
4002671154892NonePWD SR-2021-22 Vol. 1 Page No. 17 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10824.6810824.6820.19FalseNoneNoneFalseNoneFalse218550.28920
4002672154892NonePWD SR-2021-22 Vol. 1 Page No. 17 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9551.199551.198.85FalseNoneNoneFalseNoneFalse84528.03150
4002673154892NoneSR-2021-22 Vol. 1 Page No. 17 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10187.9410187.9439.92FalseNoneNoneFalseNoneFalse406702.56480
4002674154892NoneSR-2021-22 Vol. 1 Page No. 17 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9551.199551.19105.6FalseNoneNoneFalseNoneFalse1008605.6640
4002675154892NoneSR-2021-22 Vol. 1 Page No. 17 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9232.819232.812.83FalseNoneNoneFalseNoneFalse26128.85230
4002676154892NonePWD SR-2021-22 Vol. 2 Page No. 84 Item No. 11.32Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg94.7694.7623353.0425FalseNoneNoneFalseNoneFalse2212934.30730
4002677154892NoneSR-2021-22 Vol. 1 Page No. 7 Item No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum210.12210.12159.3FalseNoneNoneFalseNoneFalse33472.1160
4002678154892NoneSR-2021-22 Vol. 2 Page No. 17 Item No. 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1231.881231.88897.26FalseNoneNoneFalseNoneFalse1105316.64880
4002679154892NoneSR-2021-22 Vol. 2 Page No. 17 Item No. 6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1092.831092.83154.8918FalseNoneNoneFalseNoneFalse169270.4057940
4002680154892NoneSR-2021-22 Vol. 2 Page No. 41 Item No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm219.39219.391593.18FalseNoneNoneFalseNoneFalse349527.76020
4002681154892NoneSR-2021-22 Vol. 2 Page No. 41 Item No.8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm236.9236.9828.529FalseNoneNoneFalseNoneFalse196278.52010
4002682154892NoneSR-2021-22 Vol. 2 Page No. 46 Item No. 8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm140.08140.08828.529FalseNoneNoneFalseNoneFalse116060.342320
4002683154892NoneSR-2021-22 Vol. 2 Page 82 Item No.11.26.1Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.Kgs114.33114.33400.0FalseNoneNoneFalseNoneFalse45732.00
4002684154892NonePWD SR-2021-22 Vol. 2 Page 62 Item No.9.19Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1269.991269.99412.9FalseNoneNoneFalseNoneFalse524378.8710
4002685154892NoneSR-2021-22 Vol. 2 Page No. 45 Item No. 8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm108.15108.152057.34FalseNoneNoneFalseNoneFalse222501.3210
4002686154892NoneSR-2021-22 Vol. 2 Page No. 85 Item No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg149.35149.351142.82FalseNoneNoneFalseNoneFalse170680.1670
4002687154892NoneSR-2021-22 Vol. 2 Page No. 48 Item No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm92.792.741.49FalseNoneNoneFalseNoneFalse3846.1230
4002688154892NoneSR-2021-22 Vol. 2 Page No. 46 Item No. 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm115.36115.36828.529FalseNoneNoneFalseNoneFalse95579.105440
4002689154892NoneSR-2021-22 Vol. 2 Page No. 100 Item No. 12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum77604.3277604.320.75FalseNoneNoneFalseNoneFalse58203.240
4002690154892NoneSR-2021-22 Vol. 2 Page No. 100 Item No. 12.15Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4692.684692.6818.48FalseNoneNoneFalseNoneFalse86720.72640
4002691154892NoneSR-2021-22 Vol. 2 Page No. 108 Item No.12.69.2Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc.((125mm))Nos194.67194.6724.0FalseNoneNoneFalseNoneFalse4672.080
4002692154892NoneSR-2021-22 Vol. 2 Page No. 108 Item No.12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :Nos37.0837.088.0FalseNoneNoneFalseNoneFalse296.640
4002693154892NoneSR-2021-22 Vol. 2 Page No. 108 Item No.12.73.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :((125mm))Nos30.930.916.0FalseNoneNoneFalseNoneFalse494.40
4002694154892NoneSR-2021-22 Vol. 2 Page No. 107 Item No.12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos856.96856.968.0FalseNoneNoneFalseNoneFalse6855.680
4002695154892NoneSR-2021-22 Vol. 2 Page No. 107 Item No.12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos112.27112.278.0FalseNoneNoneFalseNoneFalse898.160
4002696154892NoneSR-2021-22 Vol. 2 Page No. 105 Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Sqm489.25489.2533.03FalseNoneNoneFalseNoneFalse16159.92750
4002697154892NoneSR-2021-22 Vol. 2 Page No. 105 Item No.12.55.2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelamSqm2941.682941.6824.78FalseNoneNoneFalseNoneFalse72894.83040
4002698154892NoneSR-2021-22 Vol. 2 Page No. 60 Item No.9.10Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm638.6638.641.022FalseNoneNoneFalseNoneFalse26196.64920
4002699154892NoneSR-2021-22 Vol. 2 Page No. 71 Item No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm992.92992.9290.72FalseNoneNoneFalseNoneFalse90077.70240
4002700154892NoneSR-2021-22 Vol. 2 Page No. 110 Item No.12.84PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm4237.424237.4248.0FalseNoneNoneFalseNoneFalse203396.160
4002701154892NoneSR-2021-22 Vol. 2 Page No. 110 Item No.12.85Providing & fixing of louvered ventilator made out of multi chambered PVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5016.15016.11.89FalseNoneNoneFalseNoneFalse9480.4290
4002702154892NoneSR-2021-22 Vol. 5 Page No.164 Item No. P440ASupply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 65x50 Head 13M, Discharge 462 LPMNos15887.7515887.752.0FalseNoneNoneFalseNoneFalse31775.50
4002703154892NoneSR-2021-22 Vol.2(1st Addenda) Item No. 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr8.248.242000.0FalseNoneNoneFalseNoneFalse16480.00
4002704154892NoneSR-2021-22 Vol. 2 Page No. 76 Item No.11.6.1Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2585.32585.349.572FalseNoneNoneFalseNoneFalse128158.49160
4002705154892NoneI.NO 4.27 Morth 406 A Vol- III Page No 24Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densityCum2465.822465.8219.1FalseNoneNoneFalseNoneFalse47097.1620
4002706154892NoneI.NO 2.1.4 Vol- I Page No 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum5899.845899.849.43FalseNoneNoneFalseNoneFalse55635.49120
4002707154892NoneI.NO 9.32 Vol- II Page No 64Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.Sqm1179.351179.35191.0829FalseNoneNoneFalseNoneFalse225353.6181150
4002708154892NoneI.NO 1.14.1 Vol- I Page No 08Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labor, tools, usage of machinery & other appurtenances required to complete the workCum75.1975.19293.15FalseNoneNoneFalseNoneFalse22041.94850
4002709154892NoneI.NO 2.1.2 Vol- I Page No15Providing and laying in position plain cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)((Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates))Cum5362.185362.1886.979FalseNoneNoneFalseNoneFalse466397.054220
4002710154892NoneI.NO 2.3.1 Vol- I Page No 16Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum9220.569220.5610.44FalseNoneNoneFalseNoneFalse96262.64640
4002711154892NoneI.NO 2.3.1 Vol- I Page No 16Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum10449.9610449.967.83FalseNoneNoneFalseNoneFalse81823.18680
4002712154892NoneI.NO 8.9 Vol- II Page No 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm331.66331.66464.16FalseNoneNoneFalseNoneFalse153943.30560
4002713154892NoneSR-2021-22 Vol. 2 Page No. 75 Item No.11.1Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs99.9199.913166.08FalseNoneNoneFalseNoneFalse316323.05280
4002714154892NoneSR-2021-22 Vol. 2 Page No.95. Item No. 11.58Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia 4 mm).Sqm696.28696.28436.5FalseNoneNoneFalseNoneFalse303926.220
4002715154892NoneSR-2021-22 Vol. 2 Page No. 48 Item No. 8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm133.9133.9436.5FalseNoneNoneFalseNoneFalse58447.350
4002716154892NoneSR-2021-22 Vol. 2 Page No. 47 Sl. No.8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm109.18109.1821.0FalseNoneNoneFalseNoneFalse2292.780
4002717154892NoneS.R. Electrical 2021-22 Chapter 1, Item No.1.1.1Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 19/20 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.19/20 mm dia 2 mm thickm68.068.0500.0FalseNoneNoneFalseNoneFalse34000.00
4002718154892NoneS.R. Electrical 2021-22 Chapter 1. Item No.1.2.2Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thickm70.070.0300.0FalseNoneNoneFalseNoneFalse21000.00
4002719154892NoneS.R. Electrical2021-22 Chapter 1, Item No.1.3.1Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal/PVE junction boxes adhesive paste etc., by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20 mm dia 2 mm thickm75.075.0250.0FalseNoneNoneFalseNoneFalse18750.00
4002720154892NoneS.R. Electrical 2021-22 Chapter 1, Item No.1.3.2Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal/PVE junction boxes adhesive paste etc., by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25 mm dia 2 mm thickm80.080.0300.0FalseNoneNoneFalseNoneFalse24000.00
4002721154892NoneS.R. Electrical 2021-22 Chapter 1, Item No.1.1.3Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 32mm dia 2.5 mm thick with Confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosure. Run with 18SWG GI fish wire wherever necessary 25 mm dia 2.5 mm thickm100.0100.0200.0FalseNoneNoneFalseNoneFalse20000.00
4002722154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-3 waysEach91.091.016.0FalseNoneNoneFalseNoneFalse1456.00
4002723154892NoneS.R. Electrical2021-22 Chapter 3, Item No.3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 waysEach122.0122.016.0FalseNoneNoneFalseNoneFalse1952.00
4002724154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 waysEach195.0195.016.0FalseNoneNoneFalseNoneFalse3120.00
4002725154892NoneS.R. Electrica 2021-22 Chapter 3, Item No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach152.0152.016.0FalseNoneNoneFalseNoneFalse2432.00
4002726154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 ModuleEach175.0175.016.0FalseNoneNoneFalseNoneFalse2800.00
4002727154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach302.0302.016.0FalseNoneNoneFalseNoneFalse4832.00
4002728154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A one way switchEach88.088.030.0FalseNoneNoneFalseNoneFalse2640.00
4002729154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way SwitchEach152.0152.010.0FalseNoneNoneFalseNoneFalse1520.00
4002730154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socketEach162.0162.010.0FalseNoneNoneFalseNoneFalse1620.00
4002731154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP SwitchEach375.0375.010.0FalseNoneNoneFalseNoneFalse3750.00
4002732154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal SocketEach249.0249.010.0FalseNoneNoneFalseNoneFalse2490.00
4002733154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.1.1Point Wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3 Mtr from tapping point to outlet via switch.No276.0276.030.0FalseNoneNoneFalseNoneFalse8280.00
4002734154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.1.2Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch.No386.0386.030.0FalseNoneNoneFalseNoneFalse11580.00
4002735154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.1.3Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to outlet via switch.No567.0567.015.0FalseNoneNoneFalseNoneFalse8505.00
4002736154892NoneS.R. Electrical 2021-22 Chapter 3, Item No.3.1.2Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654 6 Amps 3/5 wayEach143.0143.015.0FalseNoneNoneFalseNoneFalse2145.00
4002737154892NoneS.R Electrical2021-22 Chapter - 2, Item No.2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1 mm2m18.018.0250.0FalseNoneNoneFalseNoneFalse4500.00
4002738154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1.5 mm2m26.026.0250.0FalseNoneNoneFalseNoneFalse6500.00
4002739154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 2.5 mm2m40.040.0100.0FalseNoneNoneFalseNoneFalse4000.00
4002740154892NoneS.R. Electrical 2021-22 Chapter 2, Item No.2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 4 mm2m59.059.0100.0FalseNoneNoneFalseNoneFalse5900.00
4002741154892NoneS.R. Electrical 2021-22 Chapter 6, Item No.6.2.2Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.15" Sweep (450 mm)Each4126.04126.07.0FalseNoneNoneFalseNoneFalse28882.00
4002742154892NoneS.R. Electrical 2021-22 Chapter 13, Item No.13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Exhaust fanEach702.0702.07.0FalseNoneNoneFalseNoneFalse4914.00
4002743154892NoneS.R. Electrical 2021-22 Chapter 11, Item No.11.3.2Supplying of .4feet -PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours 70 percentage lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1x4 inch 20/22 wEach740.0740.050.0FalseNoneNoneFalseNoneFalse37000.00
4002744154892NoneS.R. Electrical 2021-22 Chapter 13, Item No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. Onwall/ceiling/Rafter/ GirdersEach119.0119.025.0FalseNoneNoneFalseNoneFalse2975.00
4002745154892NoneS.R. Electrical2021-22 Chapter 5, Item No.5.7.3Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 AmpsEach372.0372.025.0FalseNoneNoneFalseNoneFalse9300.00
4002746154892NoneS.R. Electrical2021-22 Chapter 5, Item No.5.17.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6 - 32 Amps DPEach1103.01103.025.0FalseNoneNoneFalseNoneFalse27575.00
4002747154892NoneS.R. Electrical 2021-22 Chapter 5, Item No.5.18.10Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.16 Way SP & NEach2650.02650.028.0FalseNoneNoneFalseNoneFalse74200.00
4002748154892NoneS.R. Electrical 2021-22 Chapter 5, Item No.5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 16 - 25 Amps 2 PoleEach2536.02536.037.0FalseNoneNoneFalseNoneFalse93832.00
4002749154892NoneS.R. Electrical 2021-22 Chapter 5, Item No.5.42.2Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG (Box 50 cm X 60 cm X 30 cm)Sq CM0.380.3852500.0FalseNoneNoneFalseNoneFalse19950.00
4002750154892NoneS.R Electrical 2021-22 Chapter 11, Item No.11.11.4Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500KEach160.0160.018.0FalseNoneNoneFalseNoneFalse2880.00
4002751154892NoneS.R Electrical 2021-22 Chapter 11, Item No.11.11.5Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500KEach237.0237.018.0FalseNoneNoneFalseNoneFalse4266.00
4002752154892NoneS.R. Electrical2021-22 Chapter 6, Item No.6.3.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M hms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.56" Sweep 5 Star (1400 mm)Each4068.04068.020.0FalseNoneNoneFalseNoneFalse81360.00
4002753154892NoneElectrical SR-2021-22 Part I Pg No.23 It No. 6.7.2Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 1.5 Ton capacityEach58900.058900.05.0FalseNoneNoneFalseNoneFalse294500.00
4002754154892NoneSR-2021-22 1st Addenda Vol. 2 Item No.13.32.1Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.). 15mm nominal dia pipesm315.18315.18160.0FalseNoneNoneFalseNoneFalse50428.80
4002755154892NoneSR-2021-22 1st Addenda Vol. 2 Item No.13.32.2Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.). 20mm nominal dia pipesm384.19384.19160.0FalseNoneNoneFalseNoneFalse61470.40
4002756154892NoneSR-2021-22 1st Addenda Vol. 2 Item No.13.32.3Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.). 25mm nominal dia pipesm490.28490.28175.0FalseNoneNoneFalseNoneFalse85799.00
4002757154892NoneSR-2021-22 1st Addenda Vol. 2 Item No.13.32.4Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.).32mm nominal dia pipesm572.68572.68110.0FalseNoneNoneFalseNoneFalse62994.80
4002758154892NoneSR-2021-22 1st Addenda Vol. 2 Item No.13.48Providing and fixing on wall face unplasticised rigid PVC Rain pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single soaked pipes 100mm diam260.59260.59100.0FalseNoneNoneFalseNoneFalse26059.00
4002759154892NoneSR-2021-22 Vol. 2 Page No. 115 Item No. 13.1.1Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :No485.13485.1350.0FalseNoneNoneFalseNoneFalse24256.50
4002760154892NoneSR-2021-22 Vol. 2 Page No 118 Item No. 13.18.1Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gNo146.26146.2640.0FalseNoneNoneFalseNoneFalse5850.40
4002761154892NoneSR-2021-22 Vol. 2 Page No. 118 Item No. 13.18.2Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 89 mm long,No155.53155.5340.0FalseNoneNoneFalseNoneFalse6221.20
4002762154892NoneSR-2021-22 Vol. 2 Page No. 115 Item No. 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNo543.84543.8415.0FalseNoneNoneFalseNoneFalse8157.60
4002763154892NoneSR-2021-22 Vol. 2 Page No. 115 Item No. 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal boreNo605.85605.8515.0FalseNoneNoneFalseNoneFalse9087.750
4002764154892NoneSR-2021-22 Vol. 2 Page No. 118 Item No. 13.17.1Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gNo152.44152.4440.0FalseNoneNoneFalseNoneFalse6097.60
4002765154892NoneSR-2021-22 Vol. 2 Page No. 115 Item No. 13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNo395.52395.5224.0FalseNoneNoneFalseNoneFalse9492.480
4002766154892NoneSR-2021-22 Vol. 2 Page No. 117 Item No. 13.11.2Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal boreSet450.11450.1124.0FalseNoneNoneFalseNoneFalse10802.640
4002767154892NoneSR-2021-22 Vol 2 Page No. 115 Item No. 13.6.1.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore HorizontalNo507.79507.7925.0FalseNoneNoneFalseNoneFalse12694.750
4002768154892NoneSR-2021-22 Vol. 2 Page No. 125 Item No. 14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerNo3706.973706.9710.0FalseNoneNoneFalseNoneFalse37069.70
4002769154892NoneCSR Vol-5, Pg. 187, It No. 9 SOR CODE T130BConstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..No5126.315126.3110.0FalseNoneNoneFalseNoneFalse51263.10
4002770154892NoneCSR Vol-5, Pg. 192, Item No. 22, SOR Code T380ASupplying and fixing SFRC frame and cover conforming to IS 12592 (part- I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete.Medium DutyNo1818.981818.9810.0FalseNoneNoneFalseNoneFalse18189.80
4002771154892NoneSR-2021-22 Vol 2 Page No. 123 Item No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach5155.155155.1512.0FalseNoneNoneFalseNoneFalse61861.80
4002772154892NoneSR-2021-22 Vol 2 Page No. 123 Item No. 14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach3642.083642.084.0FalseNoneNoneFalseNoneFalse14568.320
4002773154892NoneSR-2021-22 Vol. 2 Page No. 117 Item No. 13.10.5Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal boreNo414.06414.0636.0FalseNoneNoneFalseNoneFalse14906.160
4002774154892NoneCSR-2021-22 Vol V Page No 134 Item No. 1.1 M010FSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 (WATER SUPPLY AND SEWERAGE CSR-2021-22 Vol. V Page No. 134 Item No. 1.1 M010F)m269.16269.1650.0FalseNoneNoneFalseNoneFalse13458.00
4002775154892NoneCSR-2021-22 Vol V Page No 134 Item No. 1.1 M010GSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (WATER SUPPLY AND SEWERAGE CSR-2021-22 Vol. V Page No. 134 Item No. 1.1/M010G)m377.41377.4155.0FalseNoneNoneFalseNoneFalse20757.550
4002776154892NoneSR-2021-22 Vol 2 Page No 128 Item No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1000.131000.1310.0FalseNoneNoneFalseNoneFalse10001.30
4002777154892NoneSR-2021-22 Vol. 2 Page No 133 Item No.15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm767.35767.35265.5FalseNoneNoneFalseNoneFalse203731.4250
4002778154892NoneCOST DATA SHEET .1Supplying and errection of double pole TC structural set including all hardwares suitable for 100 to 300 KVA transformers etc., complete as per the standard technical specification.Set28491.028491.01.0FalseNoneNoneFalseNoneFalse28491.00
4002779154892NoneCOST DATA SHEET .1Supplying and erection of 9Mtr 145 Kg WL RCC pole including earth work etc. complete as per the standard technical specification - a)No8319.08319.06.0FalseNoneNoneFalseNoneFalse49914.00
4002780154892None5.8.1Supplying and fixing H frame set including all hardwares complete as per the standard technical specifications-Each4376.04376.04.0FalseNoneNoneFalseNoneFalse17504.00
4002781154892None5.8.8Supplying and fixing GOS set 200 Amps including all hardwares complete as per the standard technical specifications- GOS set 200 AmpsEach9930.09930.05.0FalseNoneNoneFalseNoneFalse49650.00
4002782154892None5.8.10Supplying and fixing Horn Gap Fuse Unit including all hardwares complete as per the standard technical specifications-No1210.01210.03.0FalseNoneNoneFalseNoneFalse3630.00
4002783154892NoneCOST DATA SHEET .24Supplying and fixing Lightning Arrestor 9KV 5 KA poymeric type including all hardwares complete as per the standard technical specifications-Each1736.01736.06.0FalseNoneNoneFalseNoneFalse10416.00
4002784154892NoneCOST DATA SHEET .24Supplying and fixing Disc Insulator 45 KN including all hardwares complete as per the standard technical specificationsNo202.0202.012.0FalseNoneNoneFalseNoneFalse2424.00
4002785154892NoneCOST DATA SHEET .24Supplying and fixing 11KV pin Insulator including all hardwares complete as per the standard technical specifications-Each221.0221.06.0FalseNoneNoneFalseNoneFalse1326.00
4002786154892NoneCOST DATA SHEET .24Supplying and fixing GUY set including all hardwares complete as per the standard technical specifications-Each1657.01657.03.0FalseNoneNoneFalseNoneFalse4971.00
4002787154892NoneBESCOMconcreting with material & labour- base concreting CC 1:4:8 (a) pole base 9/8 mtrs pole supportsNo200.0200.04.0FalseNoneNoneFalseNoneFalse800.00
4002788154892NoneCOST DATA SHEET .24Earthing Materials Pipe Type For Grounding Copper Plates 2X2 FeetSet12650.012650.08.0FalseNoneNoneFalseNoneFalse101200.00
4002789154892None5.10Supplying and fixing of PG clamp including all Hardwares etc complete as per standard technical specificationNo116.0116.015.0FalseNoneNoneFalseNoneFalse1740.00
4002790154892None55.01Supplying and fixing of Alkathine Tube of 25mm dia as per standard technocal specification.Mtr504.0504.010.0FalseNoneNoneFalseNoneFalse5040.00
4002791154892None7.07Releasing of Existing TransformerNo3163.03163.01.0FalseNoneNoneFalseNoneFalse3163.00
4002792154892None7.04Errection of Existing TransformerNo2301.02301.01.0FalseNoneNoneFalseNoneFalse2301.00
4002793154892None7.02Rabbit ACSR ConductorKms61515.061515.00.2FalseNoneNoneFalseNoneFalse12303.00
4002794154892None5501Transparent Alkathine tube 19 mm dia, 2mm thick in coils of 30 mtrsCoil504.0504.03.0FalseNoneNoneFalseNoneFalse1512.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17262284580000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17262284580000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17262284580000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17262284580000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17262284580000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17262284710000NoneNoneELIGIBILITYBlacklisted agencies/contractors are not eligible to participate in the tender.None
17262284770000NoneNoneELIGIBILITYThe work done certificate attached should be issued by an officer not below the rank of Executive EngineerNone
17262284830000NoneNoneELIGIBILITYConditional LOC (Line of credit)/ Bankers certificate shall not be accepted and the tender bid shall be reject...None
17262284890000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17262284950001NoneNoneELIGIBILITYGST Will be paid to the tendered amount separately.None
17262285020000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price lev...None
17262285190000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17262285290000NoneNoneELIGIBILITYAll conditions as per bid document attachedNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Executed in any one year for a continuous period of 12 months the following minimum quantities of work, Earthwork excavation/Embankment-435.49 cum, PCC/RCC/DLC/PQC-304.87 Cum, Reinforcement Steel/Structural Steel-21.21 Tonne, BBM/SSM Work (all types of Masonary)-375.94 Cum, Plastering work-2308.70 Sqm, Flooring-435.72 Sqm,Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done Certificates
NoneNoneNoneNoneCompany registration certificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBid capacity (AXNX1.5-B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID Capacity
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs. 274.12 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e., 2019-20 to 2023-24, satisfactory completed, at least one similar Building work of value not less than Rs. 41.118 Lakhs as prime contractorFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 68.53 Lakhs (estimated cash flow for 3 months of peak construction period (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Credit lines/ letters of credit/ certificates from banksTrueTechnical Bid
Work Done CertificateTrueTechnical Bid
List of existing commitments and ongoing worksTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsShivamoggaShikaripuraShimogaSHIKARIPURShiralkoppaNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1726573840000
version0
createdDateNone
modifiedDateNone
blockNumberDISTRICT URBAN DEVELOPMENT CELL SHIVAMOGGA DISTRICT
streetNone
cityShivamogga
stateKarnataka
pin577201
tenderRecallDTONone