createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726229812329
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3310.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-10-2024 17:30:00
tenderQueryClose27-09-2024 17:30:00
technicalBidOpen14-10-2024 11:00:00
publishedDate23-09-2024 13:07:35
publishedByPostDUDC_EE_SMG
publishedByUserKPE11254 - NADAF VAHIDA BEGUM
bidValidityPeriod90
noOfCalls1
preBidMeetingDate27-09-2024 17:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonNadaf Vahida Begum.EE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08182226868
mobileNumber8123668752
tenderSupplierListNone
tenderSchedule
createdTs1726229812381
version15
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT28719
titleConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project.
descriptionConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project.
categoryWORKS
categoryTextWorks
ecv13200793.40
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2202
locationNameDMA District Urban Development Cell Shivamogga
provisionalAmount13323000.0
groupOverheadTotal2013680.35
fileNumberSMGDC-DUDC/PLAN/90/103928/2022
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17262298120000NoneNoneBuildingsConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project. (50lakhs other work)4236330.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4003344154904NonePWD SR-2023-24 Vol. 2 Pg No. 41 Item No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as peSqm262.65262.65969.553FalseNoneNoneFalseNoneFalse254653.095450
4003345154904NonePWD SR-2023-24 - Vol. 2 Pg No.41 Item No.8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, cSqm287.37287.37457.9FalseNoneNoneFalseNoneFalse131586.7230
4003346154904NonePWD SR-2023-24 Vol.2 Pg No. 50 Item No.8.5.1Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargSqm103.0103.03018.85FalseNoneNoneFalseNoneFalse310941.550
4003347154904NoneSR-2023-24 Vol. 2 - Page No. 71 - Item No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-ChargSqm1139.181139.18172.12FalseNoneNoneFalseNoneFalse196075.66160
4003348154904NonePWD SR-2023-24 Vol. 2 Page No. 60 Item No.9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick baseSqm2539.982539.98620.31FalseNoneNoneFalseNoneFalse1575574.99380
4003349154904NonePWD SR-2023-24 Vol. 2 - Pg No. 45 Item No.8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dustSqm141.11141.11969.553FalseNoneNoneFalseNoneFalse136813.623830
4003350154904NonePWD SR-2023-24 Vol. 2 Pg No. 46 Item No. 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm160.68160.68457.9FalseNoneNoneFalseNoneFalse73575.3720
4003351154904NoneSR-2023-24 Vol. 2 - Page No. 86 - Item No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs173.04173.04535.5FalseNoneNoneFalseNoneFalse92662.920
4003352154904NonePWD SR-2023-24 Vol. 2 Pg No.109 Item No.12.84Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be madeSqm5173.695173.6925.5FalseNoneNoneFalseNoneFalse131929.0950
4003353154904NoneSR-2023-24 Vol. 2 - Page No. 99 Item No. 12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum127928.06127928.060.38FalseNoneNoneFalseNoneFalse48612.66280
4003354154904NoneSR-2023-24 Vol. 2 Pg No.100 Item No. 12.15Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7667.327667.3218.7FalseNoneNoneFalseNoneFalse143378.8840
4003355154904NoneSR-2023-24 Vol. 2 Page No. 108 Item No.12.69.2Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc.((125mm))Nos250.29250.2924.0FalseNoneNoneFalseNoneFalse6006.960
4003356154904NoneSR-2023-24 Vol. 2 Page No. 107 Item No.12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :Each84.4684.468.0FalseNoneNoneFalseNoneFalse675.680
4003357154904NoneSR-2023-24 Vol. 2 Page No. 107 Item No.12.73.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :((125mm))Each45.3245.3216.0FalseNoneNoneFalseNoneFalse725.120
4003358154904NoneSR-2023-24 Vol. 2 Page No. 105 Item No.12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1083.561083.568.0FalseNoneNoneFalseNoneFalse8668.480
4003359154904NoneSR-2023-24 Vol. 2 Page No. 105 Item No.12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos123.6123.68.0FalseNoneNoneFalseNoneFalse988.80
4003360154904NoneSR-2023-24 Vol. 2 Page No. 104 Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargem327.54327.5424.8FalseNoneNoneFalseNoneFalse8122.9920
4003361154904NoneSR-2023-24 Vol. 2 Page No. 104 Item No.12.55.2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.do- with one side prelamSqm2101.22101.27.56FalseNoneNoneFalseNoneFalse15885.0720
4003362154904NoneSR-2023-24 Vol. 2 Page 85 Item No.11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs581.95581.95500.0FalseNoneNoneFalseNoneFalse290975.00
4003363154904NoneSR-2023-24 Vol. 2 Page No.109 Item No.12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5890.575890.571.89FalseNoneNoneFalseNoneFalse11133.17730
4003364154904NoneSR 2023-24 Vol 2 P.No 149 Item No.15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm759.11759.11115.64FalseNoneNoneFalseNoneFalse87783.48040
4003365154904NoneSR-2023-24 Vol. 5 Page No.113- Item No.10.1.1Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloadim49.4449.44100.0FalseNoneNoneFalseNoneFalse4944.00
4003366154904NoneSR-2023-24 - Vol. 5 - Page No. 113- Item No.10.1.2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloadim69.0169.01100.0FalseNoneNoneFalseNoneFalse6901.00
4003367154904NoneSR-2023-24 Vol. 2 Page No. 117 Item No. 13.1.1Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. completeNos626.24626.248.0FalseNoneNoneFalseNoneFalse5009.920
4003368154904NoneSR-2023-24 Vol. 2 Page No. 120 Item No. 13.18.1Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gNos134.93134.938.0FalseNoneNoneFalseNoneFalse1079.440
4003369154904NoneSR-2023-24 Vol. 2 Page No. 120 Item No. 13.18.2Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 86 mm long,Nos148.32148.328.0FalseNoneNoneFalseNoneFalse1186.560
4003370154904NoneSR-2023-24 Vol. 2 Page No. 117 Item No. 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNos565.47565.478.0FalseNoneNoneFalseNoneFalse4523.760
4003371154904NoneSR-2023-24 Vol. 2 Page No. 117 Item No. 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal boreNos615.94615.944.0FalseNoneNoneFalseNoneFalse2463.760
4003372154904NoneSR-2023-24 Vol. 2 Page No. 118 Item No. 13.17.1Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gNos162.74162.748.0FalseNoneNoneFalseNoneFalse1301.920
4003373154904NoneSR-2023-24 Vol. 2 Page No.115 Item No. 13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNos341.96341.968.0FalseNoneNoneFalseNoneFalse2735.680
4003374154904NoneSR-2023-24 Vol. 2 Page No. 119 Item No. 13.11.2Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal boreNos581.95581.958.0FalseNoneNoneFalseNoneFalse4655.60
4003375154904NoneSR-2023-24 Vol. 2 Page No. 117 Item No. 13.6.1.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore HorizontalNos638.6638.64.0FalseNoneNoneFalseNoneFalse2554.40
4003376154904NoneSR-2023-24 Vol. 2 Page No. 123 Item No. 13.34AProviding and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flowl9.279.272000.0FalseNoneNoneFalseNoneFalse18540.00
4003377154904NoneSR-2023-24 Vol. 2 Page No. 133 Item No. 14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China WaEach4244.634244.638.0FalseNoneNoneFalseNoneFalse33957.040
4003378154904NoneSR-2023-24 Vol. 5 Page No. 191 Item No. 116.8Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 copingEach4934.734934.732.0FalseNoneNoneFalseNoneFalse9869.460
4003379154904NoneSR-2023-24 Vol. 2 Page No. 123 Item No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flushbend, overflow arrangement withEach5126.315126.318.0FalseNoneNoneFalseNoneFalse41010.480
4003380154904NoneSR-2023-24 Vol. 2 Page No. 131 Item No. 14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions aEach4587.624587.628.0FalseNoneNoneFalseNoneFalse36700.960
4003381154904NoneSR-2023-24 Vol. 2 Page No. 119 Item No. 13.10.5Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal boreNos524.27524.2716.0FalseNoneNoneFalseNoneFalse8388.320
4003382154904NoneSR-2023-24 - Vol. 5 - Page No. 113- Item No.10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloadim302.82302.82100.0FalseNoneNoneFalseNoneFalse30282.00
4003383154904NoneSR-2023-24 Vol. 5 Page No. 113- Item No.10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloadim423.33423.33100.0FalseNoneNoneFalseNoneFalse42333.00
4003384154904NoneSR-2023-24 Vol. 5 Page No.157 Item No. 13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPMEach16078.316078.31.0FalseNoneNoneFalseNoneFalse16078.30
4003385154904NoneS.R. Ele 2023-24 Chapter -1, Item No.1.1.1 Pg No 2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick S.R. Electrical Works for 2023-24 Chapter - 1, Item No.1.1.1 Page No 2Mtr69.069.0120.0FalseNoneNoneFalseNoneFalse8280.00
4003386154904NoneS.R. Elec 2023-24 Chapter 1. Item No.1.2.2 Pg No 2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 m m dia 2 mm thickS.R. Electrical Works for 2023-24 Chapter - 1. Item No.1.2.2 Page No 2Mtr78.078.080.0FalseNoneNoneFalseNoneFalse6240.00
4003387154904NoneS.R. Ele 2023-24 Chapter 1, Item No.1.3.1 Pg No 2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19 or 20 mm dia 2 mm thickMtr68.068.060.0FalseNoneNoneFalseNoneFalse4080.00
4003388154904NoneS.R. Ele 2023-24 Chapter1, Item No.1.3.2 Page No 2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick. S.R. Electrical Works for 2023-24 Chapter - 1, Item No.1.3.2 Page No 2Mtr79.079.060.0FalseNoneNoneFalseNoneFalse4740.00
4003389154904NoneS.R. El 2023-24 Chapter - 1, Item No.1.1.3 Pg No 2Supplying heavy gauge PVC conduit pipe ....... dia...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32 mm dia 2.5 mm thick S.R. Electrical Works for 2023-24 Chapter 1, Item No.1.1.3 Page No 2Each106.0106.050.0FalseNoneNoneFalseNoneFalse5300.00
4003390154904NoneS.R. Elec 2023-24 Chapter 3, Item No.3.3.2 Pg No 8Supplying and fixing surface or flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick or C.C wall, including necessary rawl plugs, Machine or NF screws etc., complete. 3 WayEach124.0124.040.0FalseNoneNoneFalseNoneFalse4960.00
4003391154904NoneS.R. Elec 2023-24 Chapter 3, Item No.3.3.3 Pg No 8Supplying and fixing surface or flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.3.3 Page No 8Each137.0137.020.0FalseNoneNoneFalseNoneFalse2740.00
4003392154904NoneS.R. El 2023-24 Chapter 3, Item No.3.3.5 Page No 8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.3.5 Page No 8)Each219.0219.030.0FalseNoneNoneFalseNoneFalse6570.00
4003393154904NoneS.R. Ele 2023-24 Chapter 3, Item No.3.5.2 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module (S.R. Electrical 2023-24 Chapter 3, Item No.3.5.2 Pg No 8)Each161.0161.040.0FalseNoneNoneFalseNoneFalse6440.00
4003394154904NoneS.R. Elect 2023-24 Chapter3, Item No.3.5.3 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.5.3 Page No 8)Each175.0175.020.0FalseNoneNoneFalseNoneFalse3500.00
4003395154904NoneS.R. Elec 2023-24 Chapter 3, Item No.3.5.5 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module (S.R. Electrical 2023-24 Chapter 3, Item No.3.5.5 Pg No 8)Each284.0284.030.0FalseNoneNoneFalseNoneFalse8520.00
4003396154904NoneS.R. Elec 2023-24 Chapter 3, Item No.3.6.1 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.1 Page No 9)Each102.0102.0140.0FalseNoneNoneFalseNoneFalse14280.00
4003397154904NoneS.R. Elec 2023-24 Chapter 3, Item No.3.6.2 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.2 Page No 9)Each166.0166.010.0FalseNoneNoneFalseNoneFalse1660.00
4003398154904NoneS.R. El 2023-24 Chapter 3, Item No.3.6.3 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.3 Page No 9)Each171.0171.052.0FalseNoneNoneFalseNoneFalse8892.00
4003399154904NoneS.R. Ele 2023-24 Chapter 3, Item No.3.6.9 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.9 Page No 9)Each326.0326.010.0FalseNoneNoneFalseNoneFalse3260.00
4003400154904NoneS.R. Ele 2023-24 Chapter 3, Item No.3.6.10 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.10 Page No 9)Each236.0236.026.0FalseNoneNoneFalseNoneFalse6136.00
4003401154904NoneS.R. Ele 2023-24 Chapter 2, Item No.2.1.1 Pg No 5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.1.1 Page No 5)Point285.0285.030.0FalseNoneNoneFalseNoneFalse8550.00
4003402154904NoneS.R. El 2023-24 Chapter 2, Item No.2.1.2 Page No 5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (S.R. Electrical 2023-24 Chapter 2, Item No.2.1.2 Page No 5)Point394.0394.050.0FalseNoneNoneFalseNoneFalse19700.00
4003403154904NoneS.R. Ele 2023-24 Chapter 2, Item No.2.1.3 Pg No 5Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to outlet via switch. (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.1.3 Page No 5)Nos570.0570.050.0FalseNoneNoneFalseNoneFalse28500.00
4003404154904NoneS.R. Ele 2023-24 Chapter 3, Item No.3.1.2 Pg No 8Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654 6 Amps 3/5 way (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.1.2 Page No 8)Each147.0147.010.0FalseNoneNoneFalseNoneFalse1470.00
4003405154904NoneS.R. Ele 2023-24 Chapter 2, Item No.2.3.1 Pg No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.1 Page No 5)m19.019.0320.0FalseNoneNoneFalseNoneFalse6080.00
4003406154904NoneS.R. Ele 2023-24 Chapter -2, Item No.2.3.2 Page, 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1.5 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.4 Page No 5)m26.026.01280.0FalseNoneNoneFalseNoneFalse33280.00
4003407154904NoneS.R. Ele 2023-24 Chapter 2, Item No.2.3.3 pg No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 2.5 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.3 Page No 5)m42.042.0640.0FalseNoneNoneFalseNoneFalse26880.00
4003408154904NoneS.R. El 2023-24 Chapter 2, Item No.2.3.4 Page No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 4 mm2m63.063.0240.0FalseNoneNoneFalseNoneFalse15120.00
4003409154904NoneS.R. Ele 2023-24 Chapter 11, It No.11.3.2 Pg No 43Supplying of .4 .feet PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (S.R. Electrical Works for 2023-24 Chapter 11, Item No.11.3.2 Page No 43)Each690.0690.060.0FalseNoneNoneFalseNoneFalse41400.00
4003410154904NoneS.R. El 2023-24 Chapter 13, It No.13.7.1 Pg No 56Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. (S.R. Electrical Works for 2023-24 Chapter - 13, Item No.13.7.1 Page No 56)Each122.0122.020.0FalseNoneNoneFalseNoneFalse2440.00
4003411154904NoneS.R. Ele 2023-24 Chapter 5, Item No.5.7.3 Pg No 14Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 Amps (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.7.3 Page No 14)Each401.0401.02.0FalseNoneNoneFalseNoneFalse802.00
4003412154904NoneS.R. Ele 2023-24 Chapter 5, It No.5.18.4 Pg No 17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 - 32 Amps DP 9S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.18.4 Page No 17)Each739.0739.010.0FalseNoneNoneFalseNoneFalse7390.00
4003413154904NoneS.R. Ele2023-24 Chapter 5, Item No.5.19.5 Pg No 18Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.19.5 Page No 18)Each2932.02932.08.0FalseNoneNoneFalseNoneFalse23456.00
4003414154904NoneS.R. Ele 2023-24 Chapter 5, It No.5.20.6 Pg No 18Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25A 4 pole (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.20.6 Page No 18)Each5066.05066.016.0FalseNoneNoneFalseNoneFalse81056.00
4003415154904NoneS.R. Ele 2023-24 Chapter 5, It No.5.17.3 Pg No 542Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.17.3 Page No 542)Each15529.015529.01.0FalseNoneNoneFalseNoneFalse15529.00
4003416154904NoneEle 2023-24 Chapter11, It No.11.11.4 Page No 47Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,RI graeter than 70 per. efficacy graeter than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF graeter than 0.95, power loss should lesser than 5per of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20per, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each154.0154.010.0FalseNoneNoneFalseNoneFalse1540.00
4003417154904NoneEle 2023-24 Chapter 11, Item No.11.11.5 Pg No 47Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. (S.R. Electrical Works for 2023-24 Chapter - 11, Item No.11.11.5 Page No 47)Each269.0269.010.0FalseNoneNoneFalseNoneFalse2690.00
4003418154904NoneESCOMs SR 2023-24 , Item No. 32.04 Page No 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975Km88418.088418.00.15FalseNoneNoneFalseNoneFalse13262.70
4003419154904NoneEl 2023-24 Chapter - 11, It No.12.56 Pg No 579Supplying, fixing, wiring, earth electrode for grounding conduits,I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.02.0FalseNoneNoneFalseNoneFalse7020.00
4003420154904NoneBESCOM Electrical 2023-24, It No. 53.17 Pg No 454.LT AC 3 Phase 4 Wire, 10-60 Amps Smart Energy Meter, Class 1.0 Accuracy with RF Communication Module (BESCOM Electrical Works for 2023-24, Item No. 53.17,Page No - 454.)No3282.03282.01.0FalseNoneNoneFalseNoneFalse3282.00
17262298120000NoneNoneBuildingsConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project. (drinking water 26.98L and LED fix10L)3077651.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4003421154905NonePWD SR-2023-24 Vol.1 Pg No. 8 It No. 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m Note: Cost of De-watering upto 5 % of (A+B) may be added, where required as sessment for dewatering shall be made as per site conditionCum105.06105.0639.14FalseNoneNoneFalseNoneFalse4112.04840
4003422154905NonePWD SR-2023-24 Vol. 1 Pg No.8 It No. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum97.8597.857.2FalseNoneNoneFalseNoneFalse704.520
4003423154905NonePWD SR-2023-24 Vol. 1 Pg No. 15 It No. 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.676.42FalseNoneNoneFalseNoneFalse39602.86140
4003424154905NonePWD SR-2023-24 Vol.1 Pg No. 15 It No. 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6403.516403.510.88FalseNoneNoneFalseNoneFalse5635.08880
4003425154905NonePWD SR-2023-24 Vol. 2 Pg No.13 It No. 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9140.229140.225.06FalseNoneNoneFalseNoneFalse46249.51320
4003426154905NonePWD SR-2023-24 Vol. 1 Pg No. 16 It No. 2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7033.77033.70.52FalseNoneNoneFalseNoneFalse3657.5240
4003427154905NonePWD SR-2023-24 Vol. 1 Pg No.16 It No. 2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7033.77033.76.0FalseNoneNoneFalseNoneFalse42202.20
4003428154905NonePWD SR-2023-24 Vol.1 Pg No. 16 It No. 2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11071.5711071.570.56FalseNoneNoneFalseNoneFalse6200.07920
4003429154905NonePWD SR-2023-24 Vol. 1 Pg No. 16 It No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10243.3510243.358.89FalseNoneNoneFalseNoneFalse91063.38150
4003430154905NonePWD SR-2023-24 Vol. 1 Pg No. 16 Item No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11609.1311609.133.05FalseNoneNoneFalseNoneFalse35407.84650
4003431154905NonePWD SR-2023-24 Vol. 1 Pg No. 16 It No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10926.2410926.240.24FalseNoneNoneFalseNoneFalse2622.29760
4003432154905NonePWD SR-2023-24 Vol.1 Pg No. 16 It No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9901.99901.90.48FalseNoneNoneFalseNoneFalse4752.9120
4003433154905NonePWD SR-2023-24 Vol. 1 Pg No.18 It No. 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour,cleaning,straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne92140.7192140.712.15FalseNoneNoneFalseNoneFalse198102.52650
4003434154905NonePWD SR-2023-24 Vol.2 Pg No. 14 Item No.6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8208.078208.0725.98FalseNoneNoneFalseNoneFalse213245.65860
4003435154905NonePWD SR-2023-24 Vol.2 Pg No. 41 It No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm262.65262.6520.92FalseNoneNoneFalseNoneFalse5494.6380
4003436154905NonePWD SR-2023-24 Vol. 2 Pg No 42 It No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm382.13382.13201.74FalseNoneNoneFalseNoneFalse77090.90620
4003437154905NonePWD SR-2023-24 Vol. 2 Pg No.46 It No. 8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm179.22179.22120.79FalseNoneNoneFalseNoneFalse21647.98380
4003438154905NonePWD SR-2023-24 Vol.2 Pg No. 45 Item No. 8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm141.11141.11110.56FalseNoneNoneFalseNoneFalse15601.12160
4003439154905NonePWD SR-2023-24 Vol. 2 Pg No.85 It No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs173.04173.0472.0FalseNoneNoneFalseNoneFalse12458.880
4003440154905NonePWD SR-2023-24 Vol. 2 Page No. 108 It No.12.84Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5173.695173.694.8FalseNoneNoneFalseNoneFalse24833.7120
4003441154905NonePWD SR-2023-24 Vol.2 Page No. 104 It No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargem327.54327.5412.0FalseNoneNoneFalseNoneFalse3930.480
4003442154905NonePWD SR-2023-24 Vol.2 Pg No.106 Item No.12.55.2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.do- with one side prelamSqm2101.22101.23.78FalseNoneNoneFalseNoneFalse7942.5360
4003443154905NonePWD SR-2023-24 Vol.2 Pg No 112 Item No.12.96Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the framem662.29662.2913.2FalseNoneNoneFalseNoneFalse8742.2280
4003444154905NonePWD SR-2023-24 Vol.2 Pg No 112 It No.12.97.1Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames 30 mm thicknessSqm3300.123300.125.04FalseNoneNoneFalseNoneFalse16632.60480
4003445154905NonePWD SR-2023-24 Vol.2-Pg No.64 It No. 9.37Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications.Sqm809.58809.5829.12FalseNoneNoneFalseNoneFalse23574.96960
4003446154905NonePWD SR-2023-24 Vol.2 Pg No.64 It No. 11.39Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer- in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg711.73711.73160.0FalseNoneNoneFalseNoneFalse113876.80
4003447154905NonePWD SR-2023-24 Vol. 2 Pg No. 150 It No. 15.6Providing and laying water proofing treatment to the Water tanks & Liq uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm522.21522.2127.9FalseNoneNoneFalseNoneFalse14569.6590
4003448154905NonePWD SR-2023-24 Vol. 2 Pg No. 43 It No. 8.12Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 90mm dia., 6 kg/sqcm & class 3Kg65.9265.9220.0FalseNoneNoneFalseNoneFalse1318.40
4003449154905NonePWD SR-2023-24 Vol.5 PgNo. 113 It No.10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 90mm dia., 6 kg/sqcm & class 3m302.82302.8290.0FalseNoneNoneFalseNoneFalse27253.80
4003450154905NonePWD SR-2023-24 Vol. 1 pg No. 7 It No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..Cum273.98273.98132.232FalseNoneNoneFalseNoneFalse36228.923360
4003451154905NonePWD SR-2023-24 Vol. 2 Pg No. A-33 It No.709Rectangular cover 600X850 mm with frame (low duty)No1802.51802.52.0FalseNoneNoneFalseNoneFalse3605.00
4003452154905NonePWD SR-2023-24 Vol. 5 PgNo.157 It No. 13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPMEach16078.316078.34.0FalseNoneNoneFalseNoneFalse64313.20
4003453154905NoneSR-2023-24 Vol. 5 Pg No. 247 It No. 21.1.9Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 500 LPH SS : Skid TypeEach336810.0336810.03.0FalseNoneNoneFalseNoneFalse1010430.00
4003454154905NonePWD Ele SR 2-23-24 Page no 2 It No 1.2.1Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickMtr66.066.090.0FalseNoneNoneFalseNoneFalse5940.00
4003455154905NonePWD Ele SR 2-23-24 Pg no 2 Item No 1.2.2Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickMtr78.078.090.0FalseNoneNoneFalseNoneFalse7020.00
4003456154905NonePWD Ele SR 2-23-24 Pg no 5 It No 2.1.3Point Wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.06.0FalseNoneNoneFalseNoneFalse3420.00
4003457154905NonePWD Ele SR 2-23-24 Page no 5 It No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 mm2Mtr19.019.090.0FalseNoneNoneFalseNoneFalse1710.00
4003458154905NonePWD Ele SR 2-23-24 Page no 5 It No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2Mtr42.042.090.0FalseNoneNoneFalseNoneFalse3780.00
4003459154905NonePWD Ele SR 2-23-24 Pg no 5 It No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010. 4.0 mm2Mtr63.063.090.0FalseNoneNoneFalseNoneFalse5670.00
4003460154905NonePWD Ele SR 2-23-24 Pg no 18 It No 5.18.14Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity CB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way SP & NEach1863.01863.03.0FalseNoneNoneFalseNoneFalse5589.00
4003461154905NonePWD Ele SR 2-23-24 Page no 18 It No 5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 poleEach4277.04277.03.0FalseNoneNoneFalseNoneFalse12831.00
4003462154905NonePWD Ele SR 2-23-24 Page no 8 It No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Model Metal Boxes 4-5 WayEach177.0177.03.0FalseNoneNoneFalseNoneFalse531.00
4003463154905NonePWD Ele SR 2-23-24 Page no 8 It No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Model Metal BoxesEach319.0319.03.0FalseNoneNoneFalseNoneFalse957.00
4003464154905NonePWD Ele SR 2-23-24 Page no 9 It No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps one way SwitchesEach102.0102.06.0FalseNoneNoneFalseNoneFalse612.00
4003465154905NonePWD Ele SR 2-23-24 Pg no 9 It No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6 amps 3 way socketEach171.0171.06.0FalseNoneNoneFalseNoneFalse1026.00
4003466154905NonePWD Ele SR 2-23-24 Pg no 9 It No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 Amps one way SwitchesEach180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
4003467154905NonePWD Ele SR 2-23-24 Pg no 43 It No 11.3.3Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Light Fitting 1 x 4 - 36/40 wattsEach1269.01269.06.0FalseNoneNoneFalseNoneFalse7614.00
4003468154905NonePWD Ele SR 2-23-24 Pg no 43 It No 5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600 mm x 600 mm x 170 mm Out door Thermoplastic Modular PanelEach14520.014520.03.0FalseNoneNoneFalseNoneFalse43560.00
4003469154905NoneESCOMs SR 2023-24 Pg no 13 It No.32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Kms141842.0141842.00.09FalseNoneNoneFalseNoneFalse12765.780
4003470154905NonePWD SR 2023-24 Vol 1 It No 1.17.1 pg No 10Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum269.86269.86102.6FalseNoneNoneFalseNoneFalse27687.6360
4003471154905NonePWD SR 2023-24 Vol 1 It No 2.11h pg No 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresTonne81381.3381381.330.499FalseNoneNoneFalseNoneFalse40609.283670
4003472154905NonePWD SR 2023-24 Vol 1 Item No 2.2.1 page No 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6993.656993.653.456FalseNoneNoneFalseNoneFalse24170.05440
4003473154905NonePWD SR 2023-24 Vol 1 It No 2.2.1 pg No 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11008.5311008.533.072FalseNoneNoneFalseNoneFalse33818.204160
4003474154905NoneMarket rateDecorative light poles: Fabricating, supplying and erection of 11 mtrs long hot dip galvanized conical pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCB's as per IS specifications suitable to withstand the wind speed of 47m/sec for 11 mtrs pole in double/single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom 200mm, top 70mm with 3 mm thick. The pole should be painted asthetically using good quality Dupont paint. The side pole should be 3 Mtr height 165 mm dia 3mm thick having 1 mtr Perforation from 1.5 mtr to 2.5 mtr height the polycorbonate pipe housed inside perforation along with color changing LED visible from all side foundation plate should be suitable to fix the 2 Nos. of 11 Mtr bent at side of this pole suitable aluminium head placed at the top including pole cover having 7 watt LED bulb inside. Suitable base plate 4 Nos. of m-24 long J bolts along with teplate and the pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM A123 and 153 etc., as shown is attached pictureEach51648.051648.08.0FalseNoneNoneFalseNoneFalse413184.00
4003475154905NonePWD Electrical Page No - 570, Item No - 11.8.5Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 120 WEach10060.010060.08.0FalseNoneNoneFalseNoneFalse80480.00
4003476154905NonePWD Electrical pg No 56, It No 13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each162.0162.08.0FalseNoneNoneFalseNoneFalse1296.00
4003477154905NonePWD Electrical Pg No 443, It No 32.081.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Kms179844.0179844.00.3FalseNoneNoneFalseNoneFalse53953.20
4003478154905NonePWD Electrical Pg No 546, It No 5.44.4Supply and Installation / Fixing / Provision of Outdoor typeThermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600 mm x 600 mm x 170 mmEach14520.014520.01.0FalseNoneNoneFalseNoneFalse14520.00
4003479154905NonePWD SR 2023-24, Page No 6, It No 2.5.2Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 1.5 mm2Mtr72.072.0104.0FalseNoneNoneFalseNoneFalse7488.00
4003480154905NonePWD SR 2023-24, Page No 6, It No 2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 10 mm2Mtr167.0167.020.0FalseNoneNoneFalseNoneFalse3340.00
4003481154905NonePWD SR 2023-24, Page No 20, It No 5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmNos305.0305.08.0FalseNoneNoneFalseNoneFalse2440.00
4003482154905NonePWD SR 2023-24, Pg No 14, It No -5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32AEach241.0241.03.0FalseNoneNoneFalseNoneFalse723.00
4003483154905NonePWD SR 2023-24, Pg No -21, It No 5.48Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.Each4843.04843.01.0FalseNoneNoneFalseNoneFalse4843.00
4003484154905NonePWD SR 2023-24, Page No-17, It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
4003485154905NoneSR 2023-24, Pg No- 455, It No -55.09Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Swith, Contactors with Single Phase 5-30 Amps meter & 50/5A CT (BESCOM SR 2023 - 24, Page No - 455, Item No - 55.09)Each5984.05984.02.0FalseNoneNoneFalseNoneFalse11968.00
4003486154905NoneSR 2023-24, Pg No 27, It No -60.02Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (ESCOM SR 2023 - 24, Page No - 27, Item No - 60.02)Each5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
4003487154905NonePWD SR 202 -24, Page No-19, It No 5.35Aluminium End Terminal (Lug) 16sqmmEach2.02.02.0FalseNoneNoneFalseNoneFalse4.00
4003488154905NoneSR 2023 24, Pg No-454, It No -53.18LT AC 3 Phase 4 Wire CT Operated, 5 Amps Smart Energy Meter, Class 0.5s Accuracy with GPRS Communication Module (BESCOM SR 2023 - 24, Page No - 454, Item No - 53.18)Each4102.04102.01.0FalseNoneNoneFalseNoneFalse4102.00
4003489154905NoneSR 2023-24 Ele Pg No - 579, It No 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (PWD SR 2023 -24 Electrical Page No - 579, Item No - 12.56)Each3510.03510.08.0FalseNoneNoneFalseNoneFalse28080.00
4003490154905NoneSR 2023 -24 Ele Pg No-527, Item No-1.1.3Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick (PWD SR 2023 -24 Electrical Page No - 527, Item No - 1.1.3)Mtr106.0106.0200.0FalseNoneNoneFalseNoneFalse21200.00
17262298120000NoneNoneBuildingsConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project. (PKS work 25Lakh)2072874.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4003491154906NoneItem No 1.14.1 pg no 8 Vol-IEarth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum75.1975.1912.0FalseNoneNoneFalseNoneFalse902.280
4003492154906NoneItem No 2.1.3 pg no 15 Vol-IProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum5720.625720.621.52FalseNoneNoneFalseNoneFalse8695.34240
4003493154906NoneItem No 2.2.1.1 pg no 15 Vol-IProviding and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (Included 50% Shuttering for Slab) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9181.949181.944.86FalseNoneNoneFalseNoneFalse44624.22840
4003494154906NoneItem No 2.2.1.1 pg no 15 Vol-IProviding and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (Included 50% Shuttering for Slab) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6121.296121.298.87FalseNoneNoneFalseNoneFalse54295.84230
4003495154906NoneItem No 5.4 pg no 9 Vol-IIProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5512.565512.567.42FalseNoneNoneFalseNoneFalse40903.19520
4003496154906NoneItem No 7.38 pg no 26 Vol-IIProviding and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Kgs572.68572.68600.6FalseNoneNoneFalseNoneFalse343951.6080
4003497154906NoneItem No 7.39.6 pg no 27 Vol-IIProviding and fixing precoated galvanised steel sheet roofing accessories 0.50mm(+0.05 %) total coated thickness, zinc coating 120 grams per m2 as per IS:277,in 240 mpa steel grade,5-7 microns epoxy primer on bith side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Gutter (600 mm over all girth)m880.65880.65171.6FalseNoneNoneFalseNoneFalse151119.540
4003498154906NoneItem No 8.8 pg no 42 Vol-IIProviding 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) Basic with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm316.21316.21187.2FalseNoneNoneFalseNoneFalse59194.5120
4003499154906NoneItem No. 8.41 Page No. 48 Vol-IIPainting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm133.9133.9763.9FalseNoneNoneFalseNoneFalse102286.210
4003500154906NoneItem No 11.2 pg no 75 Vol-IIProviding and fixing Structural Steel work riveted,bolted or welded in built up sections,trusses and frramed work,including cutting,hosting,fixing in position and applying a priming coat of approved steeel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs104.03104.034440.07FalseNoneNoneFalseNoneFalse461900.48210
4003501154906NoneItem No 11.32 pg no 84 Vol-IIProviding Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kgs94.7694.76443.2FalseNoneNoneFalseNoneFalse41997.6320
4003502154906NoneItem No 11.34A pg no 85 Vol-IIProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs149.35149.3590.72FalseNoneNoneFalseNoneFalse13549.0320
4003503154906NoneItem No. 12.54 Page No. 105 Vol-IIProviding & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Sqm489.25489.2519.84FalseNoneNoneFalseNoneFalse9706.720
4003504154906NoneItem No. 12.55.2 Page No. 106 Vol-IIProviding & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hingese.Sqm2941.682941.6819.84FalseNoneNoneFalseNoneFalse58362.93120
4003505154906NoneItem No. 12.85 Page No. 110 Vol-IIProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mmX53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mmx21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mmx1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Sqm5016.15016.12.16FalseNoneNoneFalseNoneFalse10834.7760
4003506154906NoneItem No 19.10.1 pg no 164 Vol-IIDismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum788.98788.983.77FalseNoneNoneFalseNoneFalse2974.45460
4003507154906NoneItem No 19.32 pg no 166 Vol-IIDismantling wooden ballies in posts and struts including stacking to the appropriate disposal area as per direction of Engineer-in-chargeCum11.3311.33163.8FalseNoneNoneFalseNoneFalse1855.8540
4003508154906NoneItem No 2.2.1.1 pg no 15 Vol-IProviding and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9794.069794.060.68FalseNoneNoneFalseNoneFalse6659.96080
4003509154906NoneItem No 6.1 pg no 16 Vol-IIProviding Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7163.657163.652.89FalseNoneNoneFalseNoneFalse20702.94850
4003510154906NoneIt No 8.24 pg no 45 Vol-IIDistempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm85.4985.49964.26FalseNoneNoneFalseNoneFalse82434.58740
4003511154906NoneIt No 7.39.1 pg no 23 Vol-IIProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05%) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500-600mm)Sqm371.83371.83300.3FalseNoneNoneFalseNoneFalse111660.5490
4003512154906NoneItem No13.34 Vol-IIProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr8.248.242500.0FalseNoneNoneFalseNoneFalse20600.00
4003513154906NoneItem No9.7.1 Vol-IIProviding and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1091.81091.815.6FalseNoneNoneFalseNoneFalse17032.080
4003514154906NoneItem No 6.33 pg no 17 Vol-IIProviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1092.831092.83126.08FalseNoneNoneFalseNoneFalse137784.00640
4003515154906NoneItem No 9.7.2 pg no 60 Vol-IIProviding and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.Nos1127.851127.8575.6FalseNoneNoneFalseNoneFalse85265.460
4003516154906NoneItem No 13.22.1.2 pg no.118 Vol-IIProviding and fixing PTMT grating of approved quality and colour: 125 mm nominal diaNos101.97101.978.0FalseNoneNoneFalseNoneFalse815.760
4003517154906NoneItem No 14.40.1 pg no.130 Vol-II450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.Each366.68366.688.0FalseNoneNoneFalseNoneFalse2933.440
4003518154906NoneItem No 13.17.2 pg no.118 Vol-IIProviding and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 122mm long, weighing not less than 99 gEach183.34183.348.0FalseNoneNoneFalseNoneFalse1466.720
4003519154906NoneItem No 13.4.1 pg no.118 Vol-IIProviding and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreEach543.84543.848.0FalseNoneNoneFalseNoneFalse4350.720
4003520154906NoneItem No 13.48 Vol-IIProviding and fixing on wall face unplasticised rigid PVC Rain pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single soaked pipes 100mm diam260.59260.5980.0FalseNoneNoneFalseNoneFalse20847.20
4003521154906NoneItem No 13.32.3 Vol-IIProviding and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.). 25mm nominal dia pipesm490.28490.28280.0FalseNoneNoneFalseNoneFalse137278.40
4003522154906NoneItem NoP440A Vol-IISupply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 65x50 Head 13M, Discharge 462 LPMNo15887.7515887.751.0FalseNoneNoneFalseNoneFalse15887.750
17262298120000NoneNoneBuildingsConstruction of Building and other works for the urban local Body TMC soraba Limits under Amrutha Nagarothana (Municipality) Phase-4 Project. (phsysical 21.25 Lakhs)1800256.75
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4003523154907NonePWD SR-2023-24 Vol.1 Pg No. 8 It No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m Note: Cost of De-watering upto 5 % of (A+B) may be added, where required as sessment for dewatering shall be made as per site conditionCum105.06105.0625.07FalseNoneNoneFalseNoneFalse2633.85420
4003524154907NonePWD SR-2023-24 Vol.2 Pg No. 5 It No. 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top Surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm121.54121.5419.56FalseNoneNoneFalseNoneFalse2377.32240
4003525154907NonePWD SR-2023-24 Vol.1 Pg No.15 It No. 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.676.56FalseNoneNoneFalseNoneFalse40466.47520
4003526154907NonePWD SR-2023-24 Vol.1 Pg No. 15 It No. 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6403.516403.510.44FalseNoneNoneFalseNoneFalse2817.54440
4003527154907NonePWD SR-2023-24 - Vol. 1- Page No. 7 - Item No. 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum488.22488.2226.54FalseNoneNoneFalseNoneFalse12957.35880
4003528154907NonePWD SR-2023-24 Vol.1 Pg No.16 It No. 2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7033.77033.70.26FalseNoneNoneFalseNoneFalse1828.7620
4003529154907NonePWD SR-2023-24 Vol.1 Pg No 16 It No. 2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7033.77033.73.6FalseNoneNoneFalseNoneFalse25321.320
4003530154907NonePWD SR-2023-24 Vol.1 Pg No.16 It No.2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11071.5711071.570.4FalseNoneNoneFalseNoneFalse4428.6280
4003531154907NonePWD SR-2023-24 Vol.1 Pg No. 16 It No. 2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9769.09769.06.64FalseNoneNoneFalseNoneFalse64866.160
4003532154907NonePWD SR-2023-24 Vol.1 Pg No.16 It No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11609.1311609.132.56FalseNoneNoneFalseNoneFalse29719.37280
4003533154907NonePWD SR-2023-24 Vol.1 Pg No. 16 It No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10926.2410926.245.19FalseNoneNoneFalseNoneFalse56707.18560
4003534154907NonePWD SR-2023-24 Vol.1 Pg No. 16 It No. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10243.3510243.358.57FalseNoneNoneFalseNoneFalse87785.50950
4003535154907NonePWD SR-2023-24 Vol.1 Pg No. 18 It No. 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour,cleaning,straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t92140.7192140.712.93FalseNoneNoneFalseNoneFalse269972.28030
4003536154907NonePWD SR-2023-24 Vol. 1 Pg No. 7 It No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.987.0FalseNoneNoneFalseNoneFalse1917.860
4003537154907NonePWD SR-2023-24 Vol. 2 Pg No.14 It No.6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8208.078208.0741.3FalseNoneNoneFalseNoneFalse338993.2910
4003538154907NonePWD SR-2023-24 Vol.2 Pg No.13 It No. 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9140.229140.222.53FalseNoneNoneFalseNoneFalse23124.75660
4003539154907NonePWD SR-2023-24 Vol.2 Pg No 41-It No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm262.65262.6559.714FalseNoneNoneFalseNoneFalse15683.88210
4003540154907NonePWD SR-2023-24 Vol.2 Pg No-41-It No.8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm287.37287.37167.53FalseNoneNoneFalseNoneFalse48143.09610
4003541154907NonePWD SR-2023-24 Vol.2 Pg No.60-It No.9.10Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm1139.181139.1839.67FalseNoneNoneFalseNoneFalse45191.27060
4003542154907NonePWD SR-2023-24 Vol.2 Pg No. 71-It No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade completeSqm1139.181139.1867.536FalseNoneNoneFalseNoneFalse76935.660480
4003543154907NonePWD SR-2023-24 - Vol. 2-Pg No. 45 - Item No. 8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm141.11141.1149.254FalseNoneNoneFalseNoneFalse6950.231940
4003544154907NonePWD SR-2023-24 Vol. 2-Pg No.46 It No. 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm160.68160.68167.53FalseNoneNoneFalseNoneFalse26918.72040
4003545154907NonePWD SR-2023-24-Vol. 2 Pg No. 104 - Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargem327.54327.5460.0FalseNoneNoneFalseNoneFalse19652.40
4003546154907NonePWD SR-2023-24-Vol. 2 Pg No. 104 - Item No.12.55.2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.do- with one side prelamSqm2101.22101.218.9FalseNoneNoneFalseNoneFalse39712.680
4003547154907NonePWD SR-2023-24 Vol.2-Pg 85-It No.11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs581.95581.95200.0FalseNoneNoneFalseNoneFalse116390.00
4003548154907NonePWD SR-2023-24 Vol.2 -Pg-77, It No.11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4369.264369.265.04FalseNoneNoneFalseNoneFalse22021.07040
4003549154907NonePWD SR-2023-24 -Vol.2 -Pg No.109 -It No.12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5890.575890.573.24FalseNoneNoneFalseNoneFalse19085.44680
4003550154907NonePWD SR-2023-24 Vol. 2 Pg No.149-It No.15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm841.51841.5154.621FalseNoneNoneFalseNoneFalse45964.117710
4003551154907NonePWD SR-2023-24 Vol. 2 Page No. 150 - Item No. 15.6Providing and laying water proofing treatment to the Water tanks & Liq uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm522.21522.2113.95FalseNoneNoneFalseNoneFalse7284.82950
4003552154907NonePWD SR-2023-24 Vol. 2 Page No. 43- Item No. 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.Kgs65.9265.9210.0FalseNoneNoneFalseNoneFalse659.20
4003553154907NonePWD SR-2023-24 -Vol.5 Pg No.113 It No.10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 90mm dia., 6 kg/sqcm & class 3m302.82302.8220.0FalseNoneNoneFalseNoneFalse6056.40
4003554154907NonePWD SR-2023-24 Vol. 2 Pg No. A-33 -It No.709Rectangular cover 600X850 mm with frame (low duty)No1802.51802.51.0FalseNoneNoneFalseNoneFalse1802.50
4003555154907NonePWD SR-2023-24 Vol.5 Pg No.113-It No.10.1.1Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 25mm dia, 10 kg/sqcm & class 5m49.4449.4455.0FalseNoneNoneFalseNoneFalse2719.20
4003556154907NonePWD SR-2023-24 Vol.5 Pg No.113-It No.10.1.2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 25mm dia, 10 kg/sqcm & class 5m69.0169.0155.0FalseNoneNoneFalseNoneFalse3795.550
4003557154907NonePWD SR-2023-24 Vol. 2 Pg No.117 It No.13.1.1Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. completeNos626.24626.2412.0FalseNoneNoneFalseNoneFalse7514.880
4003558154907NonePWD SR-2023-24 Vol.2 Pg No 120-It No. 13.18.1Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gNos134.93134.9312.0FalseNoneNoneFalseNoneFalse1619.160
4003559154907NonePWD SR-2023-24 Vol. 2 Pg No.120 It No. 13.18.2Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 86 mm longNos148.32148.326.0FalseNoneNoneFalseNoneFalse889.920
4003560154907NonePWD SR-2023-24 Vol. 2 Pg No.117 It No. 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNos565.47565.476.0FalseNoneNoneFalseNoneFalse3392.820
4003561154907NonePWD SR-2023-24 Vol. 2 Pg No.117-It No. 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal boreNos615.94615.945.0FalseNoneNoneFalseNoneFalse3079.70
4003562154907NonePWD SR-2023-24 Vol.2 Pg No.118 It No.13.17.1Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gNos162.74162.745.0FalseNoneNoneFalseNoneFalse813.70
4003563154907NonePWD SR-2023-24 Vol. 2 Pg No. 115-It No. 13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNos341.96341.965.0FalseNoneNoneFalseNoneFalse1709.80
4003564154907NonePWD SR-2023-24 Vol.2 Pg No.119-It No. 13.11.2Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal boreNos581.95581.954.0FalseNoneNoneFalseNoneFalse2327.80
4003565154907NonePWD SR-2023-24 Vol. 2 Pg No.117 It No. 13.6.1.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore HorizontalNos638.6638.64.0FalseNoneNoneFalseNoneFalse2554.40
4003566154907NonePWD SR-2023-24 Vol.2 Pg No.123 -ItNo. 13.34AProviding and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.l9.279.271500.0FalseNoneNoneFalseNoneFalse13905.00
4003567154907NonePWD SR-2023-24 Vol.2 Pg No. 133 It No. 14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach4244.634244.634.0FalseNoneNoneFalseNoneFalse16978.520
4003568154907NonePWD SR-2023-24 Vol.5 Pg No. 191 It No. 11.6.8Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixingCI cover & frame etc. excluding the cost of CI frame and coverEach4934.734934.734.0FalseNoneNoneFalseNoneFalse19738.920
4003569154907NonePWD SR-2023-24 Vol.2 Pg No.123 -It No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lidEach5126.315126.314.0FalseNoneNoneFalseNoneFalse20505.240
4003570154907NonePWD SR-2023-24 - Vol. 2 Pg No. 123 It No. 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5030.525030.522.0FalseNoneNoneFalseNoneFalse10061.040
4003571154907NonePWD SR-2023-24 Vol.2 Pg No.132 It No. 14.6.1Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required:Single squatting plate with 5 litre P.V.C. automatic flushing cisternEach6818.66818.64.0FalseNoneNoneFalseNoneFalse27274.40
4003572154907NonePWD SR-2023-24 Vol.2 Pg No. 131 -It No. 14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach4587.624587.626.0FalseNoneNoneFalseNoneFalse27525.720
4003573154907NonePWD SR-2023-24 - Vol. 2 Pg No. 119 It No. 13.10.5Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal boreNos524.27524.278.0FalseNoneNoneFalseNoneFalse4194.160
4003574154907NonePWD SR-2023-24 Vol.5 Pg No. 113- ItNo.10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 90mm dia., 6 kg/sqcm & class 3m302.82302.8250.0FalseNoneNoneFalseNoneFalse15141.00
4003575154907NonePWD SR-2023-24 Vol.5 Pg No.113-It No.10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3m423.33423.3345.0FalseNoneNoneFalseNoneFalse19049.850
4003576154907NonePWD SR-2023-24 Vol. 5 -Pg No.157 Item No. 13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPMEach16078.316078.32.0FalseNoneNoneFalseNoneFalse32156.60
4003577154907NoneS.R. El2023-24 Chptr 1, Item No.1.1.1 Page No 2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.050.0FalseNoneNoneFalseNoneFalse3450.00
4003578154907NoneS.R. Ele 2023-24 Chapt -1. It No.1.2.2 Pg No 2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick (S.R. Electrical Works for 2023-24 Chapter - 1. Item No.1.2.2 Page No 2)Mtr78.078.050.0FalseNoneNoneFalseNoneFalse3900.00
4003579154907NoneS.R. Ele 2023-24 Chapt 1, It No.1.3.1 Pg No 2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (S.R. Electrical Works for 2023-24 Chapter - 1, Item No.1.3.1 Page No 2)Mtr68.068.050.0FalseNoneNoneFalseNoneFalse3400.00
4003580154907NoneS.R. Ele2023-24 Chapt-1, It No.1.3.2 Pg No 2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick (S.R. Electrical Works for 2023-24 Chapter - 1, Item No.1.3.2 Page No 2)Mtr79.079.050.0FalseNoneNoneFalseNoneFalse3950.00
4003581154907NoneS.R. Ele 2023-24 Chptr-1, It No.1.1.3 Pg No 2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32 mm dia 2.5 mm thickMtr106.0106.060.0FalseNoneNoneFalseNoneFalse6360.00
4003582154907NoneS.R. Ele2023-24 Chapt -3, It No.3.3.2 Pg No 8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way (S.R. Electrical Works for 2023-24 Chapter-3, Item No.3.3.2 Page No 8)Each124.0124.04.0FalseNoneNoneFalseNoneFalse496.00
4003583154907NoneS.R. Ele2023-24 Chapt-3, It No.3.3.3 Pg No 8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.3.3 Page No 8)Each137.0137.04.0FalseNoneNoneFalseNoneFalse548.00
4003584154907NoneS.R. Ele 2023-24 Chapt-3, It No.3.3.5 Pg No 8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.3.5 Page No 8)Each219.0219.04.0FalseNoneNoneFalseNoneFalse876.00
4003585154907NoneS.R. Ele2023-24 Chapt-3, It No.3.5.2 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.5.2 Page No 8)Each161.0161.04.0FalseNoneNoneFalseNoneFalse644.00
4003586154907NoneS.R. Ele 2023-24 Chapt -3, It No.3.5.3 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.5.3 Page No 8)Each175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
4003587154907NoneS.R. Ele2023-24 Chapt-3, It No.3.5.5 Pg No 8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.5.5 Page No 8)Each284.0284.04.0FalseNoneNoneFalseNoneFalse1136.00
4003588154907NoneS.R. Ele2023-24 Chapt-3, It No.3.6.1 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.1 Page No 9)Each102.0102.04.0FalseNoneNoneFalseNoneFalse408.00
4003589154907NoneS.R. Ele2023-24 Chapt-3, It No.3.6.2 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.2 Page No 90Each166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
4003590154907NoneS.R. Ele 2023-24 Chapt-3, It No.3.6.3 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (S.R. Electrical Works for 2023-24 Chapt-3, It No.3.6.3 Pg No 9)Each171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
4003591154907NoneS.R. Ele 2023-24 Chapt-3, It No.3.6.9 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.9 Page No 9)Each326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
4003592154907NoneS.R. Ele 2023-24 Chapt-3, It No.3.6.10 Pg No 9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.6.10 Page No 9)Each236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
4003593154907NoneS.R. Elc 2023-24 Chapt-2, It No.2.1.1 Pg No 5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.1.1 Page No 5)Point285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
4003594154907NoneS.R. Ele 2023-24 Chapt-2, It No.2.1.2 Pg No 5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.1.2 Page No 5)Point394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
4003595154907NoneS.R. Ele 2023-24 Chapt-2, It No.2.1.3 Pg No 5Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to outlet via switch. (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.1.3 Page No 5)Nos570.0570.04.0FalseNoneNoneFalseNoneFalse2280.00
4003596154907NoneS.R. Ele 2023-24 Chapt-3, It No.3.1.2 Pg No 8Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654 6 Amps 3/5 way (S.R. Electrical Works for 2023-24 Chapter - 3, Item No.3.1.2 Page No 8)Each147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
4003597154907NoneS.R. Ele 2023-24 Chapt-2, It No.2.3.1 Pg No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.1 Page No 5)m19.019.040.0FalseNoneNoneFalseNoneFalse760.00
4003598154907NoneS.R. Ele2023-24 Chapter 2, Item No.2.3.2 Page No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1.5 mm2m26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
4003599154907NoneS.R. Ele2023-24 Chapt-2, It No.2.3.3 Pg No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 2.5 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.3 Page No 5)m42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
4003600154907NoneS.R. Ele2023-24 Chapt-2, It No.2.3.4 Pg No 5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 4 mm2 (S.R. Electrical Works for 2023-24 Chapter - 2, Item No.2.3.4 Page No 5)m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
4003601154907None2023-24 Chapt 11, Item No.11.3.2 Page No 43Supplying of .4 feet -PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each690.0690.04.0FalseNoneNoneFalseNoneFalse2760.00
4003602154907NoneS.R. Ele2023-24 Chapt-13, It No.13.7.1 Pg No 56Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. (S.R. Electrical Works for 2023-24 Chapter - 13, Item No.13.7.1 Page No 56)Each122.0122.04.0FalseNoneNoneFalseNoneFalse488.00
4003603154907NoneS.R. Ele 2023-24 Chapter-5, It No.5.7.3 Pg No 14Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 Amps (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.7.3 Page No 14)Each401.0401.04.0FalseNoneNoneFalseNoneFalse1604.00
4003604154907NoneS.R. Ele2023-24 Chapt -5, It No.5.18.4 Pg No 17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 - 32 Amps DP (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.18.4 Page No 17)Each739.0739.04.0FalseNoneNoneFalseNoneFalse2956.00
4003605154907NoneS.R. Ele2023-24 Chapt-5, It No.5.19.5 Pg No 18Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.19.5 Page No 18)Each2932.02932.04.0FalseNoneNoneFalseNoneFalse11728.00
4003606154907NoneS.R. Ele2023-24 Chapt -5, It No.5.20.6 Pg No 18Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25A 4 pole (S.R. Electrical Works for 2023-24 Chapter - 5, Item No.5.20.6 Page No 18)Each5066.05066.04.0FalseNoneNoneFalseNoneFalse20264.00
4003607154907NoneS.R. Ele2023-24 Chptr 5, Item No.5.42.2 Page No 20Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.430.432500.0FalseNoneNoneFalseNoneFalse1075.00
4003608154907NoneS.R. Ele2023-24 Chapt-11, It No.11.11.4 Pg No 47Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PFgreater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. (S.R. Electrical Works for 2023-24 Chapter - 11, Item No.11.11.4 Page No 47)Each154.0154.04.0FalseNoneNoneFalseNoneFalse616.00
4003609154907NoneS.R. Ele 2023-24 Chapt-11, It No.11.11.5 Pg No 47Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. (S.R. Electrical Works for 2023-24 Chapter - 11, Item No.11.11.5 Page No 47)Each269.0269.05.0FalseNoneNoneFalseNoneFalse1345.00
4003610154907NoneESCOMs SR 2023-24 , Item No. 32.04 Page No 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975Km88418.088418.00.01FalseNoneNoneFalseNoneFalse884.180
4003611154907NoneS.R. Ele 2023-24 Chptr 11, It No.12.56 Page No 579Supplying, fixing, wiring, earth electrode for grounding conduits,I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (S.R. Electrical Works for 2023-24 Chapter - 11, Item No.12.56 Page No 579)No3510.03510.02.0FalseNoneNoneFalseNoneFalse7020.00
4003612154907NoneBESCOM Ele2023-24, It No. 53.17,Pg No - 454.LT AC 3 Phase 4 Wire, 10-60 Amps Smart Energy Meter, Class 1.0 Accuracy with RF Communication Module (BESCOM Electrical Works for 2023-24, Item No. 53.17,Page No - 454.)No3282.03282.02.0FalseNoneNoneFalseNoneFalse6564.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17262298130000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17262298130000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17262298130000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17262298130000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17262298130000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17262298310000NoneNoneELIGIBILITYBlacklisted agencies/contractors are not eligible to participate in the tender.None
17262298400000NoneNoneELIGIBILITYThe work done certificate attached should be issued by an officer not below the rank of Executive EngineerNone
17262298450000NoneNoneELIGIBILITYConditional LOC (Line of credit)/ Bankers certificate shall not be accepted and the tender bid shall be reject...None
17262298510000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17262298560001NoneNoneELIGIBILITYGST Will be paid to the tendered amount separatelyNone
17262298630000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price levelNone
17262298690000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17262298740000NoneNoneELIGIBILITYAll conditions as per bid document attachedNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e., 2019-20 to 2023-24, satisfactory completed, at least one similar Building work of value not less than Rs. 55.93 Lakhs as prime contractorPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Executed in any one year for a continuous period of 12 months the following minimum quantities of work, Earthwork excavation/Embankment 143.52 cum, PCC/RCC/DLC/PQC 65.89 Cum, Reinforcement Steel/Structural Steel 8.30 Tonne, BBM/SSM Work (all types of Masonary) 166.56 Cum, Plastering work 1634.91 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done Certificates
NoneNoneNoneNoneCompany registration certificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBid capacity (AXNX1.5-B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID Capacity
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs. 223.74 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 33.56 Lakhs (estimated cash flow for 3 months of peak construction period (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- loc
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Credit lines/ letters of credit/ certificates from banksTrueTechnical Bid
Work Done CertificateTrueTechnical Bid
List of existing commitments and ongoing worksTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsShivamoggaSorabaShimogaSORABSoraba TMCNoneNoneNoneNoneNoneNone
BuildingsShivamoggaSorabaShimogaSORABSorabaNoneNoneNoneNoneNoneNone
BuildingsShivamoggaSorabaShimogaSORABsorabaNoneNoneNoneNoneNoneNone
BuildingsShivamoggaSorabaShimogaSORABSorabaNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1726573771000
version0
createdDateNone
modifiedDateNone
blockNumberDISTRICT URBAN DEVELOPMENT CELL SHIVAMOGGA DISTRICT
streetNone
cityShivamogga
stateKarnataka
pin577201
tenderRecallDTONone