createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725520632370
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd28500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-09-2024 16:30:00
tenderQueryClose27-09-2024 16:00:00
technicalBidOpen01-10-2024 16:45:00
publishedDate23-09-2024 11:55:40
publishedByPostTP_CO_BLGN
publishedByUserKPE17303 - GARADI KALAKA MALLESHA
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonMeenaxamma
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber7022169727
tenderSupplierListNone
tenderSchedule
createdTs1725520632373
version14
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT25458/CALL-2
titleConstruction Of Shed Material Recovery Facility In Balaganur TP Limits.
descriptionConstruction Of Shed Material Recovery Facility In Balaganur TP Limits.
categoryWORKS
categoryTextWorks
ecv1130054.63
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2381
locationNameDMA Town Panchayat Balaganuru
provisionalAmount1140000.0
groupOverheadTotalNone
fileNumberTPBAL/SBM2/MRF/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17255206320001NoneNoneBuildingsConstruction Of Shed Material Recovery Facility In Balaganur TP Limits.1130054.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3927238151437Nonecode01Clearing and Grubbing Road Land : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. ( CM SR 2023-24 P.No. 7/Vol-3/ 2.5 (ii)/A ) By Mechanical Means using Dozer, In area of light jungleSqm486.92486.9248.0FalseNoneNoneFalseNoneFalse23372.160
3927239151437Nonecode02Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete In ordinary/soft rock without blasting upto 1.5 m depth. In all kinds of soils Depth upto 3 m ( CM SR 2023-24 P.No. 8/Vol-1/ 1.15.1 )Cum126.37126.3745.4FalseNoneNoneFalseNoneFalse5737.1980
3927240151437Nonecode03Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete In ordinary/soft rock without blasting upto 1.5 m depth. In all kinds of soils Depth upto 3 m ( CM SR 2023-24 P.No. 8/Vol-1/ 1.15.1 )Cum126.37126.3740.86FalseNoneNoneFalseNoneFalse5163.47820
3927241151437Nonecode04Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete In ordinary/soft rock without blasting upto 1.5 m depth. In all kinds of soils Depth upto 3 m ( CM SR 2023-24 P.No. 8/Vol-1/ 1.15.1 )Cum449.75449.754.54FalseNoneNoneFalseNoneFalse2041.8650
3927242151437Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ( CM SR 2023-24 P.No.15/Vol-1/2.1.3 )Cum7420.377420.373.936FalseNoneNoneFalseNoneFalse29206.576320
3927243151437Nonecode06Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coaSDe sand) (CM SR 2023-24/P.No.9/Vol-2/5.4)Cum7915.977915.9713.464FalseNoneNoneFalseNoneFalse106580.620080
3927244151437Nonecode07Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately))(CM SR 2023-24/P.No.16/Vol-1/2.4.2) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8460.938460.933.5279FalseNoneNoneFalseNoneFalse29849.3149470
3927245151437Nonecode08Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (CM SR 2023-24/P.No.16/Vol-1/2.3.1)Cum11751.2911751.292.358FalseNoneNoneFalseNoneFalse27709.541820
3927246151437Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (CM SR 2023-24/P.No.16/Vol-1/2.5.1)Cum13143.3113143.314.716FalseNoneNoneFalseNoneFalse61983.849960
3927247151437Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (CM SR 2023-24/P.No.16/Vol-1/2.5.1)Cum13964.7613964.763.6179FalseNoneNoneFalseNoneFalse50523.1052040
3927248151437Nonecode11KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne110837.22110837.221.362FalseNoneNoneFalseNoneFalse150960.293640
3927249151437Nonecode12Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CM SR 2023-24/P.No.7/Vol-1/1.9) Filling.Cum329.57329.5721.119FalseNoneNoneFalseNoneFalse6960.188830
3927250151437Nonecode13Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (CM SR 2023-24/P.No.26/Vol-3/4.17)Cum3170.63170.67.728FalseNoneNoneFalseNoneFalse24502.39680
3927251151437Nonecode14Providing and constructing un-reinforced plain cementconcrete pavement, thickness as per design, over a preparedsub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregatesconforming to IS:383:2016:, maximum size of coarseaggregate not exceeding 25 mm, mixed in a concrete mixerof not less than 0.2 cum capacity and appropriate weighbatcher using approved mix design, laid in approved fixedside formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (CM SR 2023-24/P.No.149/Vol-3/16.28)Cum12552.312552.39.6FalseNoneNoneFalseNoneFalse120502.080
3927252151437Nonecode15Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CM SR 2023-24/P.No.82/Vol-2/11.16.1)Kg168.5168.5960.0FalseNoneNoneFalseNoneFalse161760.00
3927253151437Nonecode16Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( CM SR 2023-24/ P.No.17/Vol-2/6.32)Cum1623.091623.095.424FalseNoneNoneFalseNoneFalse8803.640160
3927254151437Nonecode17Providing 18mm cement plaster in two coats under layer 12mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with atuoplayer 6mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24 V-2,/P.No.42, I-8.8)Sqm459.66459.6657.86FalseNoneNoneFalseNoneFalse26595.92760
3927255151437Nonecode18Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24/P.No.46/Vol-2/8.30)Sqm215.58215.5864.7FalseNoneNoneFalseNoneFalse13948.0260
3927256151437Nonecode19Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approvedsteel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. (CM SR 2023-24/P.No.21/Vol-2/7.1.1) 0.63 mm thick with zinc coating not less than 275 g/ m²Sqm1089.081089.0855.8FalseNoneNoneFalseNoneFalse60770.6640
3927257151437Nonecode20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)Each7396.927396.924.0FalseNoneNoneFalseNoneFalse29587.680
3927258151437Nonecode21Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Four Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24)Each10315.0910315.093.0FalseNoneNoneFalseNoneFalse30945.270
3927259151437Nonecode22Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24)Each255.23255.236.0FalseNoneNoneFalseNoneFalse1531.380
3927260151437Nonecode23Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 63 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)Each1452.41452.43.0FalseNoneNoneFalseNoneFalse4357.20
3927261151437Nonecode24Supplying.........A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Strips (P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24)Mtr2995.962995.964.0FalseNoneNoneFalseNoneFalse11983.840
3927262151437Nonecode25Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat......with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)Mtr370.69370.696.0FalseNoneNoneFalseNoneFalse2224.140
3927263151437Nonecode26Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)Sqm0.60.635000.0FalseNoneNoneFalseNoneFalse21000.00
3927264151437Nonecode27Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24)Each1567.861567.862.0FalseNoneNoneFalseNoneFalse3135.720
3927265151437Nonecode28Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)Each5886.185886.181.0FalseNoneNoneFalseNoneFalse5886.180
3927266151437Nonecode29Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)Each1616.481616.483.0FalseNoneNoneFalseNoneFalse4849.440
3927267151437Nonecode30Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24)Each549.51549.512.0FalseNoneNoneFalseNoneFalse1099.020
3927268151437Nonecode31Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)Each741.22741.222.0FalseNoneNoneFalseNoneFalse1482.440
3927269151437Nonecode32Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)Each565.16565.164.0FalseNoneNoneFalseNoneFalse2260.640
3927270151437Nonecode33Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)Each549.36549.361.0FalseNoneNoneFalseNoneFalse549.360
3927271151437Nonecode34Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)Each243.07243.074.0FalseNoneNoneFalseNoneFalse972.280
3927272151437Nonecode35Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)Each194.46194.461.0FalseNoneNoneFalseNoneFalse194.460
3927273151437Nonecode36Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)Each683.05683.054.0FalseNoneNoneFalseNoneFalse2732.20
3927274151437Nonecode37Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)Each1185.011185.011.0FalseNoneNoneFalseNoneFalse1185.010
3927275151437Nonecode38Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)Kvar583.39583.395.0FalseNoneNoneFalseNoneFalse2916.950
3927276151437Nonecode391.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13Km217523.78217523.780.01FalseNoneNoneFalseNoneFalse2175.23780
3927277151437Nonecode401.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13Km218582.39218582.390.01FalseNoneNoneFalseNoneFalse2185.82390
3927278151437Nonecode411.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13Km172394.76172394.760.02FalseNoneNoneFalseNoneFalse3447.89520
3927279151437Nonecode421.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13Km143422.06143422.060.02FalseNoneNoneFalseNoneFalse2868.44120
3927280151437Nonecode43Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT cable 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52Km25384.8425384.840.06FalseNoneNoneFalseNoneFalse1523.09040
3927281151437Nonecode4435 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52Km37846.3437846.340.03FalseNoneNoneFalseNoneFalse1135.39020
3927282151437Nonecode45Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24 In all kind of soils, Depth upto 1.50mCum588.25588.256.75FalseNoneNoneFalseNoneFalse3970.68750
3927283151437Nonecode46Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 2.5 to 25 Sqmm .ESCOM SR 2023-24 I No. 22.13 Pg.53Set114.24114.2412.0FalseNoneNoneFalseNoneFalse1370.880
3927284151437Nonecode47Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53Set230.92230.922.0FalseNoneNoneFalseNoneFalse461.840
3927285151437Nonecode48Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr83.8683.8625.0FalseNoneNoneFalseNoneFalse2096.50
3927286151437Nonecode4925mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr98.4498.4425.0FalseNoneNoneFalseNoneFalse2461.00
3927287151437Nonecode5032mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr128.83128.8320.0FalseNoneNoneFalseNoneFalse2576.60
3927288151437Nonecode5140mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr181.09181.0920.0FalseNoneNoneFalseNoneFalse3621.80
3927289151437Nonecode52Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5Nos346.38346.385.0FalseNoneNoneFalseNoneFalse1731.90
3927290151437Nonecode53Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos478.86478.865.0FalseNoneNoneFalseNoneFalse2394.30
3927291151437Nonecode54Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5Nos692.77692.774.0FalseNoneNoneFalseNoneFalse2771.080
3927292151437Nonecode55Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos860.5860.52.0FalseNoneNoneFalseNoneFalse1721.00
3927293151437Nonecode56Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1257.931257.932.0FalseNoneNoneFalseNoneFalse2515.860
3927294151437Nonecode57Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr23.0923.09200.0FalseNoneNoneFalseNoneFalse4618.00
3927295151437Nonecode581.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr31.631.680.0FalseNoneNoneFalseNoneFalse2528.00
3927296151437Nonecode592.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr51.0451.0440.0FalseNoneNoneFalseNoneFalse2041.60
3927297151437Nonecode604.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr76.5776.5740.0FalseNoneNoneFalseNoneFalse3062.80
3927298151437Nonecode616.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr111.81111.8130.0FalseNoneNoneFalseNoneFalse3354.30
3927299151437Nonecode62Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8Nos418.09418.095.0FalseNoneNoneFalseNoneFalse2090.450
3927300151437Nonecode633 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5Nos195.67195.674.0FalseNoneNoneFalseNoneFalse782.680
3927301151437Nonecode64Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8Nos150.7150.75.0FalseNoneNoneFalseNoneFalse753.50
3927302151437Nonecode6510-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8Nos317.21317.215.0FalseNoneNoneFalseNoneFalse1586.050
3927303151437Nonecode66Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos123.97123.974.0FalseNoneNoneFalseNoneFalse495.880
3927304151437Nonecode676A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9Nos207.83207.834.0FalseNoneNoneFalseNoneFalse831.320
3927305151437Nonecode686/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9Nos286.83286.832.0FalseNoneNoneFalseNoneFalse573.660
3927306151437Nonecode69Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. PowerFactor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application.Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with.......W System Power consumption.LED Efficiency 1301m/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. LED flood light 100W PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46Nos11529.2811529.281.0FalseNoneNoneFalseNoneFalse11529.280
3927307151437Nonecode70GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54Mtr99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
3927308151437Nonecode712 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55 300x50mmMtr713.43713.434.0FalseNoneNoneFalseNoneFalse2853.720
3927309151437Nonecode72Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54Nos4266.054266.051.0FalseNoneNoneFalseNoneFalse4266.050
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17255206320000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17255206320000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17255206320000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17255206320000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17255206320000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17255206320000NoneNoneELIGIBILITYAs per bid documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDepartment Registration DetailsNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing workNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker DetailsNoneNone
NoneNoneNoneNonePWD Contractor Registration CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneSatisfactory completed, at least one similar Work of value not less (50%) than Rs. 6.20 Lakhs. as prime contractor Work done Certificate issued by the officer not below the rank of Asst. Executive Engineer or Above OfficerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in one year (for a continues period of 12 months) the following minimum quantities of work (usually 80% of the annual of requirement) by the officer not below the rank of Executive Engineer or EquivalentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid assets and or availability of credit (30%) facilities of no less than Rs.3.42 Lakhs (Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc. (Bank Certificate)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Contractor Registration CertificateTrueTechnical Bid
Annual Turnover CertificateTrueTechnical Bid
GST and PAN CARD Registration CertificateTrueTechnical Bid
Unbalanced amount less DDTrueTechnical Bid
Bankers certificate Unconditional /Line of CreditTrueTechnical Bid
Similar nature of Work done CertificateTrueTechnical Bid
Executed 80 Percentage Work Done QuantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone