tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1726918709000 | 0 | None | None | Other Works | CONSTRUCTION OF SHOPS BEHIND JAGALUR BUS STAND AND MUTTON MARKET ROAD IN WARD NO.14 (Electrical Work) | 894318.32 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4049133 | 157180 | None | 2.1.3 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Short point upto 3Mtr from tapping point to out let via switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Point | 276.0 | 276.0 | 60.0 | False | None | None | False | None | False | 16560.0 | 0 | 4049134 | 157180 | None | 2.1.3 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Point | 386.0 | 386.0 | 60.0 | False | None | None | False | None | False | 23160.0 | 0 | 4049135 | 157180 | None | 2.1.3 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Point | 567.0 | 567.0 | 60.0 | False | None | None | False | None | False | 34020.0 | 0 | 4049136 | 157180 | None | 3.6.11 | Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6A One Way Switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 88.0 | 88.0 | 180.0 | False | None | None | False | None | False | 15840.0 | 0 | 4049137 | 157180 | None | 3.6.11 | Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6A Three Way socket ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 162.0 | 162.0 | 120.0 | False | None | None | False | None | False | 19440.0 | 0 | 4049138 | 157180 | None | 3.6.8 | Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) Stepped Fan Regulator Two Module ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 313.0 | 313.0 | 60.0 | False | None | None | False | None | False | 18780.0 | 0 | 4049139 | 157180 | None | 7.0 | Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 16A One Way Switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 249.0 | 249.0 | 60.0 | False | None | None | False | None | False | 14940.0 | 0 | 4049140 | 157180 | None | 8.0 | Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6/16A Universal Socket ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 249.0 | 249.0 | 60.0 | False | None | None | False | None | False | 14940.0 | 0 | 4049141 | 157180 | None | 9.0 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 ( P-3, I-2.3.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 26.0 | 26.0 | 500.0 | False | None | None | False | None | False | 13000.0 | 0 | 4049142 | 157180 | None | 10.0 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 ( P-3, I-2.3.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 40.0 | 40.0 | 300.0 | False | None | None | False | None | False | 12000.0 | 0 | 4049143 | 157180 | None | 11.0 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 ( P-3, I-2.3.4) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 59.0 | 59.0 | 120.0 | False | None | None | False | None | False | 7080.0 | 0 | 4049144 | 157180 | None | 12.0 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way (Item No 3.3.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 122.0 | 122.0 | 60.0 | False | None | None | False | None | False | 7320.0 | 0 | 4049145 | 157180 | None | 13.0 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way (Item No 3.3.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 149.0 | 149.0 | 60.0 | False | None | None | False | None | False | 8940.0 | 0 | 4049146 | 157180 | None | 14.0 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10/12 Way (Item No 3.3.5) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 277.0 | 277.0 | 15.0 | False | None | None | False | None | False | 4155.0 | 0 | 4049147 | 157180 | None | 11.4.3 | Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greater than70%. efficacy greater than 100 lumen per watt, 120 degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 3) 15-18W (P-34, I-11.4.3)
---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 2174.0 | 2174.0 | 60.0 | False | None | None | False | None | False | 130440.0 | 0 | 4049148 | 157180 | None | 12.46 | Supplying & Fixing of 70-150 W lamp holder 2 Pin ( P-43, I-12.46) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 118.0 | 118.0 | 60.0 | False | None | None | False | None | False | 7080.0 | 0 | 4049149 | 157180 | None | 1.1.2 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick (P-01, I.No.- 1.1.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 80.0 | 80.0 | 500.0 | False | None | None | False | None | False | 40000.0 | 0 | 4049150 | 157180 | None | 3.7 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230V 50Hz AC supply & completetly wired on existing box.(P-06,I-3.7) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 747.0 | 747.0 | 60.0 | False | None | None | False | None | False | 44820.0 | 0 | 4049151 | 157180 | None | 5.7.2 | Supplying & fixing of 32Amps Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.(P-10,I-5.7.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 200.0 | 200.0 | 60.0 | False | None | None | False | None | False | 12000.0 | 0 | 4049152 | 157180 | None | 5.17.6 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63Amps DP. (P-13, I-5.17.6) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 1376.0 | 1376.0 | 60.0 | False | None | None | False | None | False | 82560.0 | 0 | 4049153 | 157180 | None | 12.52.2 | Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting. (P-41,I-12.25.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 310.0 | 310.0 | 60.0 | False | None | None | False | None | False | 18600.0 | 0 | 4049154 | 157180 | None | 12.12.1 | Supplying and fixing/replacing of fluorescent tube. 18 to 40W (P-39, I-12.12.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 92.0 | 92.0 | 60.0 | False | None | None | False | None | False | 5520.0 | 0 | 4049155 | 157180 | None | 11.2.2 | Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI greater than70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18-20 W (P-34, I-11.2.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 691.0 | 691.0 | 10.0 | False | None | None | False | None | False | 6910.0 | 0 | 4049156 | 157180 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model (P-22,I No 6.3.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 2085.0 | 2085.0 | 60.0 | False | None | None | False | None | False | 125100.0 | 0 | 4049157 | 157180 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (P-46,I-13.10) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 162.0 | 162.0 | 60.0 | False | None | None | False | None | False | 9720.0 | 0 | 4049158 | 157180 | None | 3.14.5 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose (P-6, I.no-3.14.5) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 63.0 | 63.0 | 60.0 | False | None | None | False | None | False | 3780.0 | 0 | 4049159 | 157180 | None | 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long gburied in a pit…The pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia. (P-40, I-6.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 2999.7 | 2999.7 | 20.0 | False | None | None | False | None | False | 59994.0 | 0 | 4049160 | 157180 | None | 32.5 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm (BESCOM Part3 P-9, I no.-32.5) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 183442.0 | 183442.0 | 0.06 | False | None | None | False | None | False | 11006.52 | 0 | 4049161 | 157180 | None | 6.5.1 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 6 sqmm to 16 sqmm (I no.-6.5.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Km | 11.88 | 11.88 | 60.0 | False | None | None | False | None | False | 712.8 | 0 | 4049162 | 157180 | None | 7.20.1 | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 40mm OD / 32mm ID (I no.-7.20.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 98.0 | 98.0 | 60.0 | False | None | None | False | None | False | 5880.0 | 0 | 4049163 | 157180 | None | 31.0 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)CC Cutting ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Mtr | 205.0 | 205.0 | 60.0 | False | None | None | False | None | False | 12300.0 | 0 | 4049164 | 157180 | None | 13.7 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders. (P-45,I-13.7) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 119.0 | 119.0 | 130.0 | False | None | None | False | None | False | 15470.0 | 0 | 4049165 | 157180 | None | 5.3 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. (P-18, I-5.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | No | 1380.0 | 1380.0 | 60.0 | False | None | None | False | None | False | 82800.0 | 0 | 4049166 | 157180 | None | 21.11 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angleof size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec.No. As directed by Engineer in Charge & MoRTH specification 804 (Vol-03 SR-2021-22 SL.NO.21.11 PG NO-151) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 |
| 1726918709000 | 0 | None | None | Other Works | CONSTRUCTION OF SHOPS BEHIND JAGALUR BUS STAND AND MUTTON MARKET ROAD IN WARD NO.14(CIVIL WORK) | 9903006.48 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4049167 | 157181 | None | 2.7 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Lime /Cement Concrete by manual means Lime Concrete, cement concrete grade M-10 and below(Vol-03 SR-2023-24 P No 10 I NO 2.7(1)(i)a)
---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 824.25 | 824.25 | 192.4 | False | None | None | False | None | False | 158585.7 | 0 | 4049168 | 157181 | None | 1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth upto 1.5 m (Vol-01 SR-2023-24 P No 05 I NO 1.4.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 254.1 | 254.1 | 480.61 | False | None | None | False | None | False | 122123.001 | 0 | 4049169 | 157181 | None | 3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (Vol-3 SR-2023-24 I no 3.1 P No 17) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 89.25 | 89.25 | 480.61 | False | None | None | False | None | False | 42894.4425 | 0 | 4049170 | 157181 | None | 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(Vol-1 SR-2023-24 P NO-7 SL.NO.1.8 ) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 497.7 | 497.7 | 103.95 | False | None | None | False | None | False | 51735.915 | 0 | 4049171 | 157181 | None | 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Vol-01 SR-2023-24 P No 15 I NO 2.1.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 5947.2 | 5947.2 | 75.22 | False | None | None | False | None | False | 447348.384 | 0 | 4049172 | 157181 | None | 2.4.3 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Vol-01 SR-2023-24 P No 16 I NO 2.4.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 6652.8 | 6652.8 | 44.06 | False | None | None | False | None | False | 293122.368 | 0 | 4049173 | 157181 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(Vol-02 SR-2023-24 P No 9 I NO 5.4) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 6708.45 | 6708.45 | 110.12 | False | None | None | False | None | False | 738734.514 | 0 | 4049174 | 157181 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-01 SR-2023-24 P No 16 I NO 2.5.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 7185.15 | 7185.15 | 158.26 | False | None | None | False | None | False | 1137121.839 | 0 | 4049175 | 157181 | None | 1.0 | addendum 1-Additionalities for Formwork, centering & Scaffolding Foundation upto Plinth all other type (3%) (Vol-01 SR-2023-24 P.No.111 Sl.No.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 199.58 | 199.58 | 44.06 | False | None | None | False | None | False | 8793.4948 | 0 | 4049176 | 157181 | None | 2.0 | addendum 1-Additionalities for Formwork, centering & Scaffolding Plinth beams of buildings (50%) (Vol-01 SR-2023-24 P.No.111 Sl.No.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 3592.58 | 3592.58 | 33.05 | False | None | None | False | None | False | 118734.769 | 0 | 4049177 | 157181 | None | 9.0 | addendum 1-Additionalities for Formwork, centering & ScaffoldingRCC Columns / Shaft (Slip Centering)(70%) (Vol-01 SR-2023-24 P.No.111 Sl.No.9) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 5029.61 | 5029.61 | 23.11 | False | None | None | False | None | False | 116234.2871 | 0 | 4049178 | 157181 | None | 14.0 | addendum 1-Additionalities for Formwork, centering & ScaffoldingRCC Beams, Lintels & Troughs of AqueductsSlip Centering)(60%) (Vol-01 SR-2023-24 P.No.112 Sl.No.14) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 4311.09 | 4311.09 | 34.45 | False | None | None | False | None | False | 148517.0505 | 0 | 4049179 | 157181 | None | 15.0 | addendum 1-Additionalities for Formwork, centering & ScaffoldingRCC Roof Slabs(50%) (Vol-01 SR-2023-24 P.No.112 Sl.No.15) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Cum | 3592.58 | 3592.58 | 67.65 | False | None | None | False | None | False | 243038.037 | 0 | 4049180 | 157181 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Vol-02 SR-2023-24 P No 17 I NO 6.32) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 1375.5 | 1375.5 | 1207.64 | False | None | None | False | None | False | 1661108.82 | 0 | 4049181 | 157181 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification(Vol-1 SR-2023-24 P No 18 I NO 2.11 a) (buildings) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Tonne | 93929.85 | 93929.85 | 16.93 | False | None | None | False | None | False | 1590232.3605 | 0 | 4049182 | 157181 | None | 11.6.1 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(Vol-02 SR-2023-24 P No 78 I NO 11.6.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 2764.65 | 2764.65 | 311.85 | False | None | None | False | None | False | 862156.1025 | 0 | 4049183 | 157181 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol-02 SR-203-24 P No 41 I NO 8.1.1) 3rd quarter issue rate ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 267.75 | 267.75 | 1362.15 | False | None | None | False | None | False | 364715.6625 | 0 | 4049184 | 157181 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol-02 SR-2023-24 P No 42 I NO 8.8) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 389.55 | 389.55 | 860.47 | False | None | None | False | None | False | 335196.0885 | 0 | 4049185 | 157181 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.(Vol-02 SR-2023-24 P No 60 I NO 9.12.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 1202.25 | 1202.25 | 426.0 | False | None | None | False | None | False | 512158.5 | 0 | 4049186 | 157181 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol-02 SR-2023-24 P No 50 I NO 8.51) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 105.0 | 105.0 | 1708.65 | False | None | None | False | None | False | 179408.25 | 0 | 4049187 | 157181 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol-02 SR-2023-24 P No 46 I NO 8.32) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 163.8 | 163.8 | 1708.65 | False | None | None | False | None | False | 279876.87 | 0 | 4049188 | 157181 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-02 SR-2023-24 P No 46 I NO 8.30) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 182.7 | 182.7 | 860.47 | False | None | None | False | None | False | 157207.869 | 0 | 4049189 | 157181 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-02 SR-2023-24 P No 47 I NO 8.33.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 145.95 | 145.95 | 613.8 | False | None | None | False | None | False | 89584.11 | 0 | 4049190 | 157181 | None | 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Vol-02 SR-23-2024 I.No. 11.25.2 P.No. 84) assumimg each chamber as 25kg ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Sqm | 142.8 | 142.8 | 1550.0 | False | None | None | False | None | False | 221340.0 | 0 | 4049191 | 157181 | None | 10.1.2 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for(pg No.113 I.No.10.1.2 Vol-5 2023-24 SR) PVC pipes 32mm dia., 10 kg/sqcm & class 5 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | m | 70.35 | 70.35 | 240.0 | False | None | None | False | None | False | 16884.0 | 0 | 4049192 | 157181 | None | 4.0 | Providing and fixing RCC name board of size 1.35x0.60x0.04 m fixed in reinforced cement concrete poles of size 0.10x0.10x2.60m in cement concrete M 20 proportion using 20mm and down size graded metal machine mixed with 10mm dia main steel bars and 8mm dia stirpes as shown in drawing. The board shall be provided with 12mm thick cement plaster in cement mortar 1:4 on both the sides. The poles shall be embedded in the ground for a depth of 0.5 m with cement concrete M 10 proportion. The board shall be fixed as per the drawing and at the place indicated by the Engineer in charge of the work. The cost includes excavation, cost of all materials, cost of steel, painting, centering, transportation charges & fixing charges. (Vol-3 P NO 151 SL NO 4) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. | Each | 6154.05 | 6154.05 | 1.0 | False | None | None | False | None | False | 6154.05 | 0 |
|
|
---|