4066435 | 158136 | None | C001 | manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage and other appurtenances required to complete the work | Cum | 93.73 | 93.73 | 25.0 | False | None | None | False | None | False | 2343.25 | 0 |
4066436 | 158136 | None | C002 | Earth work excavation by manual means for drains canals waste weir draft approach channels key trenches foundation of bridges and such simillar works in all kinds of soils as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools and other appurtenaces required to complete the work. in all kinds of soil Depth upto 1.5m | Cum | 249.26 | 249.26 | 160.0 | False | None | None | False | None | False | 39881.6 | 0 |
4066437 | 158136 | None | C003 | Providing and Filling in foundation with granite trap broken metal 100mm. and down size and with approved sand including hand packing ramming watering including cost of all materials and labour with all lead and lift. complete as per specifications | Cum | 2762.46 | 2762.46 | 25.0 | False | None | None | False | None | False | 69061.5 | 0 |
4066438 | 158136 | None | C004 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 1:4:8 M5 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 20.0 | False | None | None | False | None | False | 116678.4 | 0 |
4066439 | 158136 | None | C005 | Providing and laying in position Reinforced cement concrete for all Sub structures of building Irrigation works Sub structure works of bridges Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necesary including all lead and lifts cost of all materials of quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separatelyM25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates RCC WALLS AND DRAINS | Cum | 8810.21 | 8810.21 | 24.0 | False | None | None | False | None | False | 211445.04 | 0 |
4066440 | 158136 | None | C006 | Providing and laying in position Reinforced cement concrete for all Sub structures of building Irrigation works Sub structure works of bridges Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necesary including all lead and lifts cost of all materials of quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separatelyM25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates RCC slab | Cum | 9789.12 | 9789.12 | 2.0 | False | None | None | False | None | False | 19578.24 | 0 |
4066441 | 158136 | None | C007 | Supplying fitting and placing TMT FE 550 550D Steel Reinforcementincluding cost of all materials machinery labour cleaning straightening cutting bending hooking laping welding joints tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification . All other type of structures | Tonne | 81381.33 | 81381.33 | 3.2 | False | None | None | False | None | False | 260420.256 | 0 |
4066442 | 158136 | None | C008 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brick stone masonary including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge | Sqm | 364.62 | 364.62 | 230.0 | False | None | None | False | None | False | 83862.6 | 0 |
4066443 | 158136 | None | C009 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives New work Two coats applied @ 1.43 litre 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre 10 m² with paint of approved quality to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge | Sqm | 160.68 | 160.68 | 230.0 | False | None | None | False | None | False | 36956.4 | 0 |
4066444 | 158136 | None | C010 | Providing and fixing Steel work in built up tubular round square or rectangular hollow tubes etc. trusses etc. including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge | Kgs | 151.41 | 151.41 | 1000.0 | False | None | None | False | None | False | 151410.0 | 0 |
4066445 | 158136 | None | C011 | Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats square or round bars etc. including primingcoat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc | Kgs | 188.49 | 188.49 | 500.0 | False | None | None | False | None | False | 94245.0 | 0 |
4066446 | 158136 | None | C012 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour including lowering into trenches laying true to line level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg m2: 160mm | Rmtr | 665.38 | 665.38 | 60.0 | False | None | None | False | None | False | 39922.8 | 0 |
4066447 | 158136 | None | C013 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6 bed concrete 150mm thick with 1:3:6 plastering 12 mm thick with cement mortar 1:4 CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover | No | 5617.62 | 5617.62 | 6.0 | False | None | None | False | None | False | 33705.72 | 0 |
4066448 | 158136 | None | C014 | Providing and fixing 455x610 mm cast iron cover with frame weight to be not less 38Kgs weight of cover 23 Kgs and weight of frame 15 Kgsand necessary locking arrangements with M.S flats 32x6 mm etc and painting with two or more coats with black Japan paint etc. complete as directed by the engineer in charge | No | 2020.86 | 2020.86 | 6.0 | False | None | None | False | None | False | 12125.16 | 0 |
4066449 | 158136 | None | C015 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour including lowering into trenches laying true to line level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg m2: 110mmweight of pipe 1.894 kg | Rmtr | 368.74 | 368.74 | 20.0 | False | None | None | False | None | False | 7374.8 | 0 |
4066450 | 158136 | None | C016 | Providing and fixing chorinated poly vinyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete. external work.V2 item no 13.33.4 Crri 01 32mm nominal OD pipes | Rmtr | 383.16 | 383.16 | 30.0 | False | None | None | False | None | False | 11494.8 | 0 |
4066451 | 158136 | None | C017 | Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 40mm size aggregate | Cum | 1225.7 | 1225.7 | 10.0 | False | None | None | False | None | False | 12257.0 | 0 |
4066452 | 158136 | None | C018 | Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 20mm size aggregate | Cum | 1372.99 | 1372.99 | 10.0 | False | None | None | False | None | False | 13729.9 | 0 |
4066453 | 158136 | None | C019 | Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 06mm size aggregate | Cum | 1452.3 | 1452.3 | 10.0 | False | None | None | False | None | False | 14523.0 | 0 |
4066454 | 158136 | None | C020 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 1 cement : 6 coarse sand including cost of all materials labour scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work | Cum | 8208.07 | 8208.07 | 4.0 | False | None | None | False | None | False | 32832.28 | 0 |
4066455 | 158136 | None | C021 | Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m | Cum | 273.98 | 273.98 | 160.0 | False | None | None | False | None | False | 43836.8 | 0 |
4066456 | 158136 | None | C022 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge | Sqm | 118.45 | 118.45 | 99.0 | False | None | None | False | None | False | 11726.55 | 0 |
4066457 | 158136 | None | C023 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts bolts and washers as required complete as per the direction of Engineer in charge. Made of G.I. wire of dia 4 mm | Sqm | 827.09 | 827.09 | 99.0 | False | None | None | False | None | False | 81881.91 | 0 |
4066458 | 158136 | None | C024 | Providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by Engineer in charge 0.50 mm 0.05 % total coated thickness with zinc coating 120 grams per m2 as per IS: 277 in 240 mpa steel grade 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in charge. The sheet shall be fixed using self drilling self tapping screws of size 5.5x 55 mm with EPDM seal complete upto any pitch in horizontal vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required | Sqm | 585.04 | 585.04 | 31.0 | False | None | None | False | None | False | 18136.24 | 0 |
4066459 | 158136 | None | C025 | Electrical : Supplying of Three phase 2HP Submersible Raw water Sewage mud pumpsets 5M3 hr capacity and 7.5 Rmtr Head pump sets. CI | No | 15491.07 | 15491.07 | 2.0 | False | None | None | False | None | False | 30982.14 | 0 |
4066460 | 158136 | None | C026 | Supplying of Three phase 2HP SubmersibleFilter Feed pump sets 5M3 hr capacity and 15 Rmtr Head pump sets.CI | No | 27444.64 | 27444.64 | 1.0 | False | None | None | False | None | False | 27444.64 | 0 |
4066461 | 158136 | None | C027 | Supplying of Three phase 2HP Submersible Aerator pump sets 15M3 hr Air capacity .CI | No | 32991.07 | 32991.07 | 1.0 | False | None | None | False | None | False | 32991.07 | 0 |
4066462 | 158136 | None | C028 | Supplying Installation and Commissioning of Dual Media Filter with multi port valve and Required media | No | 34392.86 | 34392.86 | 1.0 | False | None | None | False | None | False | 34392.86 | 0 |
4066463 | 158136 | None | C029 | Supplying and fixing of DANGER BOARD made out of MS sheet metal with two coats of non corrossive enamel paint | No | 61.5 | 61.5 | 2.0 | False | None | None | False | None | False | 123.0 | 0 |
4066464 | 158136 | None | C030 | Supplying and Installation of RUBBER MAT 1mt X 2mt 10mm thick | No | 906.1 | 906.1 | 1.0 | False | None | None | False | None | False | 906.1 | 0 |
4066465 | 158136 | None | C031 | Supply and laying double walled corrugated DWC HDPE Pipe including all necessary connecting Sockets Couplings Tees Bends End caps of same materials in exisiting trench as per IS 14930 part II suitable for drawing under ground cables.50mm OD 38mm | Mtr | 134.82 | 134.82 | 180.0 | False | None | None | False | None | False | 24267.6 | 0 |
4066466 | 158136 | None | C032 | Fabricating supplying and mounting MS box made out 16 SWG suitable for floor wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland a nd box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc. complete. 16 SWG | Sq CM | 0.44 | 0.44 | 125000.0 | False | None | None | False | None | False | 55000.0 | 0 |
4066467 | 158136 | None | C033 | Supplying 100 amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls nuts and washers etc. complete 100Amps 4x30x6mm Aluminium Strips | Mtr | 2538.95 | 2538.95 | 0.5 | False | None | None | False | None | False | 1269.475 | 0 |
4066468 | 158136 | None | C034 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32Amps TPN MCB | No | 1768.51 | 1768.51 | 8.0 | False | None | None | False | None | False | 14148.08 | 0 |
4066469 | 158136 | None | C035 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 .50 63Amps TPN MCB | No | 3180.64 | 3180.64 | 6.0 | False | None | None | False | None | False | 19083.84 | 0 |
4066470 | 158136 | None | C036 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 Amps D.P | No | 761.17 | 761.17 | 4.0 | False | None | None | False | None | False | 3044.68 | 0 |
4066471 | 158136 | None | C037 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood panel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic release Micro processor release shall have Earth Fault as per IS 13947. Icu = 100% Ics.In 4P MCCB all poles should have protection for short circuit over load for Microprocessor MCCB'S Facility for segregating Priority and Non Priority loads must be available in the MCCB . MCCB shall be provided with double insulation Insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi pole breakers shall be designed to break all the poles simeltaneously and they shall have a single mechanism. 100 Amps 25kA 4 Pole | No | 8741.61 | 8741.61 | 1.0 | False | None | None | False | None | False | 8741.61 | 0 |
4066472 | 158136 | None | C038 | Supplying of multi function digital meter with three line back light LCD type display for voltage Current frequency Power power factor KVA KWH KVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | No | 9594.45 | 9594.45 | 1.0 | False | None | None | False | None | False | 9594.45 | 0 |
4066473 | 158136 | None | C039 | Supplying fixing and wiring 50 5 to 400 5Amps 5VA burden Current Transformer.class 0.5 accurecy with Tape Wound | No | 578.86 | 578.86 | 3.0 | False | None | None | False | None | False | 1736.58 | 0 |
4066474 | 158136 | None | C040 | Supplying and running Copper conductor for grounding and along with other wires in conduit system of wiring using necessary suitable size clamps nails guttas spacers etc. 8 SWG Copper Wire | Mtr | 105.0 | 105.0 | 80.0 | False | None | None | False | None | False | 8400.0 | 0 |
4066475 | 158136 | None | C041 | Supplying and running of GI Copper strips for grounding connections using necessary fixing materials as required.600x600x3mm Copper plate | No | 6900.0 | 6900.0 | 2.0 | False | None | None | False | None | False | 13800.0 | 0 |
4066476 | 158136 | None | C042 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230 440v A.C 50Hz 12 24v D.C | No | 530.45 | 530.45 | 2.0 | False | None | None | False | None | False | 1060.9 | 0 |
4066477 | 158136 | None | C043 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm | Mtr | 314.15 | 314.15 | 8.0 | False | None | None | False | None | False | 2513.2 | 0 |
4066478 | 158136 | None | C044 | 1.1 kv XLPE or Heat resistant PVC insulated PVC extruted Inner seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975. 25 Sqmm 3.5 core 12 GI Strips 4 X 0.8mm | Km | 143735.47 | 143735.47 | 0.11 | False | None | None | False | None | False | 15810.9017 | 0 |
4066479 | 158136 | None | C045 | Providing Laying and Fixing of GI pipes conforming to IS 1239:1990with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary including testingfor water tightness with all lead and commissioning. contractor will make his own Arrangements for procuring water for testing For:Heavy Duty GI Pipe etc. complete | Mtr | 424.36 | 424.36 | 20.0 | False | None | None | False | None | False | 8487.2 | 0 |
4066480 | 158136 | None | C046 | Earth work excavation by manual means for drains canals waste weir draft approach channels key trenches foundation of bridges and such simillar works in all kinds of soils as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools and other appurtenaces required to complete the work.V1 P 5 1.4.1 in all kinds of soil Depth upto 1.5m | Cum | 249.26 | 249.26 | 20.0 | False | None | None | False | None | False | 4985.2 | 0 |
4066481 | 158136 | None | C047 | Refilling available earth around trenches pipelines cables in layers notexceeding 20 cms in depth ompacting each deposited layer by ramming afterwatering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 20.0 | False | None | None | False | None | False | 3296.0 | 0 |
4066482 | 158136 | None | C048 | Laying of cable in Existing Trench GI Pipe Stoneware RCC Hume pipe using Wooden Aluminium Rollers as directed by the departmental staff. LT Cable 2.5 sqmm to 25 sqmm | Km | 21512.58 | 21512.58 | 0.15 | False | None | None | False | None | False | 3226.887 | 0 |
4066483 | 158136 | None | C049 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 :1990 Confirming to latest amendments. 2.5Sqmm | Mtr | 43.26 | 43.26 | 300.0 | False | None | None | False | None | False | 12978.0 | 0 |
4066484 | 158136 | None | C050 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 Confirming to latest amendments. 4 Sqmm | Mtr | 64.89 | 64.89 | 230.0 | False | None | None | False | None | False | 14924.7 | 0 |
4066485 | 158136 | None | C051 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 Confirming to latest amendments. 16 Sqmm | Mtr | 327.54 | 327.54 | 10.0 | False | None | None | False | None | False | 3275.4 | 0 |
4066486 | 158136 | None | C052 | Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick | Mtr | 83.43 | 83.43 | 300.0 | False | None | None | False | None | False | 25029.0 | 0 |
4066487 | 158136 | None | C053 | Supplying PVC flexible conduit pipe 25 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on the either end of the pipe terminated completely. 25mm | Mtr | 74.16 | 74.16 | 38.0 | False | None | None | False | None | False | 2818.08 | 0 |
4066488 | 158136 | None | C054 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130 1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS 694:2010. 3C x 4.0 Sqmm | Mtr | 173.04 | 173.04 | 187.0 | False | None | None | False | None | False | 32358.48 | 0 |
4066489 | 158136 | None | C055 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrossion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230 440 volts 3 phase motor single phase motor upto 5HP | No | 1984.51 | 1984.51 | 8.0 | False | None | None | False | None | False | 15876.08 | 0 |
4066490 | 158136 | None | C056 | Labour charges for Errection Electrification and commissioning of Pump sets including aligning and balancing of all items including supply and errection of two pair of supporting clamps borewell caps cable clips and water tight gland cable protectors bolts nuts valve and gauges tools and equipments etc involved in the job as per the specifications with Necessary testing as per specifications with testing of as per the instructions of engineer in charge of work | No | 6695.0 | 6695.0 | 3.0 | False | None | None | False | None | False | 20085.0 | 0 |
4066491 | 158136 | None | C057 | Labour charges for the errection of Indoor type panel boardUNITS with all necessary materials and labour tools and equipments including cement concrete for foundation bed etc complete as per specification with testing of as per instructions of engineer in charge of work | Job | 1390.5 | 1390.5 | 1.0 | False | None | None | False | None | False | 1390.5 | 0 |
4066492 | 158136 | None | C058 | Digging of Pit for providing G I pipe type earthing. Hard soil | No | 3079.7 | 3079.7 | 3.0 | False | None | None | False | None | False | 9239.1 | 0 |
4066493 | 158136 | None | C059 | Grounding materials Pipe type grounding G I grounding Pipe B class 42mm dia 2.5 mtr long 3.2mm thick with bolts nut G I strips and washer complete | No | 765.29 | 765.29 | 3.0 | False | None | None | False | None | False | 2295.87 | 0 |
4066494 | 158136 | None | C060 | Good quality well burnt charcoal for grounding purposes packed in non returnable gunny bagg of 30 kg each | No | 696.28 | 696.28 | 3.0 | False | None | None | False | None | False | 2088.84 | 0 |
4066495 | 158136 | None | C061 | Good Quality salt for grounding purposes packed in 50 kg gunny bag | Bag | 319.3 | 319.3 | 3.0 | False | None | None | False | None | False | 957.9 | 0 |
4066496 | 158136 | None | C062 | ACTVATED SAND FILTERS :Providing and fixing of 0.8 m dia pressure sand filter comprising of 5 mm thick 0.8 m dia shell joined with 10 mm thick M S flanges and Air vent pipe with gate value graded filter media comprising of sand pebbles grit etc complete as per direction of engineer in charge including all lead and lifts as per the direction of engineer in charge of work APPVD RATE | No | 78000.0 | 78000.0 | 1.0 | False | None | None | False | None | False | 78000.0 | 0 |
4066497 | 158136 | None | C063 | BELT SKIMMER : Providing and fixing of BELT SKIMMER with 5 LPH tray with complete arrangement for skimming out oil etc complete including all lead and lifts as per the direction of engineer in charge of work APPVD RATE | Set | 45000.0 | 45000.0 | 1.0 | False | None | None | False | None | False | 45000.0 | 0 |
4066498 | 158136 | None | C064 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70% CCT 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains Surge Protection Min 5KV along with Over voltage Overload short circuit miss wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598 LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m w nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given of LED Floodlight 70W | No | 6971.04 | 6971.04 | 3.0 | False | None | None | False | None | False | 20913.12 | 0 |
4066499 | 158136 | None | C065 | Fixing halogen metal halide SVL IL LED floodlight fitting over existing pole wall ceiling including clA bolts nuts and wiring using suitable capacity wires | No | 203.94 | 203.94 | 3.0 | False | None | None | False | None | False | 611.82 | 0 |
4066500 | 158136 | None | C066 | Pressure Sand Filter: Providing and fixing of 0.8m dia Pressure sand filter comprising of 5mm thick 0.8mm dia shell joined sand with 10 mm thick MS Flanges and air vent pipe with gate valve graded filter media comprising of sand pebbles grit etc. complete as per direction of engg inchargeApproved rate | No | 75000.0 | 75000.0 | 1.0 | False | None | None | False | None | False | 75000.0 | 0 |
4066501 | 158136 | None | C067 | Dozing pumps with tanks providing fixing of poly electrode dozing tanks comprising of 100 litre capacity LDPE tank with electronic metering pump etc complete Approved rate | No | 10500.0 | 10500.0 | 1.0 | False | None | None | False | None | False | 10500.0 | 0 |