tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727242634000 | 0 | None | None | Buildings | Construction of New Anganawadi Building at Kenganur village in Bailhongal Taluka | 774632.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4070862 | 158377 | None | code01 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7978.0 | 7978.0 | 31.43 | False | None | None | False | None | False | 250748.54 | 0 | 4070863 | 158377 | None | code02 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 976.0 | 976.0 | 16.57 | False | None | None | False | None | False | 16172.32 | 0 | 4070864 | 158377 | None | code03 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 136.0 | 136.0 | 16.28 | False | None | None | False | None | False | 2214.08 | 0 | 4070865 | 158377 | None | code04 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 333.0 | 333.0 | 200.84 | False | None | None | False | None | False | 66879.72 | 0 | 4070866 | 158377 | None | code05 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 255.0 | 255.0 | 127.89 | False | None | None | False | None | False | 32611.95 | 0 | 4070867 | 158377 | None | code06 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1326.0 | 1326.0 | 53.33 | False | None | None | False | None | False | 70715.58 | 0 | 4070868 | 158377 | None | code07 | Ceramic Glazed Tiles Ist quality 300 x 300mm in all shades and designs of White, Ivory, grey, Fuem Red brown etc. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 495.0 | 495.0 | 6.16 | False | None | None | False | None | False | 3049.2 | 0 | 4070869 | 158377 | None | code08 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1449.0 | 1449.0 | 14.87 | False | None | None | False | None | False | 21546.63 | 0 | 4070870 | 158377 | None | code09 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 136.0 | 136.0 | 32.96 | False | None | None | False | None | False | 4482.56 | 0 | 4070871 | 158377 | None | code10 | Cudddapah slab 2.5cms thick with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 462.0 | 462.0 | 20.48 | False | None | None | False | None | False | 9461.76 | 0 | 4070872 | 158377 | None | code11 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 3359.0 | 3359.0 | 6.05 | False | None | None | False | None | False | 20321.95 | 0 | 4070873 | 158377 | None | code12 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 764.0 | 764.0 | 23.0 | False | None | None | False | None | False | 17572.0 | 0 | 4070874 | 158377 | None | code13 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 764.0 | 764.0 | 5.46 | False | None | None | False | None | False | 4171.44 | 0 | 4070875 | 158377 | None | code14 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder /rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. (Cost of Fixtures to be paid separately)30 mm thickness with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 3485.0 | 3485.0 | 8.82 | False | None | None | False | None | False | 30737.7 | 0 | 4070876 | 158377 | None | code15 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder /rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. (Cost of Fixtures to be paid separately)30 mm thickness with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 3485.0 | 3485.0 | 1.6 | False | None | None | False | None | False | 5576.0 | 0 | 4070877 | 158377 | None | code16 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 5390.0 | 5390.0 | 9.0 | False | None | None | False | None | False | 48510.0 | 0 | 4070878 | 158377 | None | code17 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 5390.0 | 5390.0 | 0.36 | False | None | None | False | None | False | 1940.4 | 0 | 4070879 | 158377 | None | code18 | Hold fasts with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 50.0 | 50.0 | 32.0 | False | None | None | False | None | False | 1600.0 | 0 | 4070880 | 158377 | None | code19 | Door lock.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 348.0 | 348.0 | 5.0 | False | None | None | False | None | False | 1740.0 | 0 | 4070881 | 158377 | None | code20 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 107.0 | 107.0 | 20.0 | False | None | None | False | None | False | 2140.0 | 0 | 4070882 | 158377 | None | code21 | Providing and fixing magnetic catcher of approved quality in cupboard /
ward robe shutters, including fixing with necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 59.0 | 59.0 | 16.0 | False | None | None | False | None | False | 944.0 | 0 | 4070883 | 158377 | None | code22 | Brass screws 25 mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 250.0 | 250.0 | 1.2 | False | None | None | False | None | False | 300.0 | 0 | 4070884 | 158377 | None | code23 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 237.0 | 237.0 | 8.0 | False | None | None | False | None | False | 1896.0 | 0 | 4070885 | 158377 | None | code24 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 130.0 | 130.0 | 5.0 | False | None | None | False | None | False | 650.0 | 0 | 4070886 | 158377 | None | code25 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after horoughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 158.0 | 158.0 | 210.16 | False | None | None | False | None | False | 33205.28 | 0 | 4070887 | 158377 | None | code26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 100.0 | 100.0 | 200.88 | False | None | None | False | None | False | 20088.0 | 0 | 4070888 | 158377 | None | code27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 158.0 | 158.0 | 187.08 | False | None | None | False | None | False | 29558.64 | 0 | 4070889 | 158377 | None | code28 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 53.0 | 53.0 | 16.32 | False | None | None | False | None | False | 864.96 | 0 | 4070890 | 158377 | None | code29 | Engaging Painter Class I for Educational Wall art painting with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Days | 514.28 | 514.28 | 8.0 | False | None | None | False | None | False | 4114.24 | 0 | 4070891 | 158377 | None | code30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 183.0 | 183.0 | 293.76 | False | None | None | False | None | False | 53758.08 | 0 | 4070892 | 158377 | None | code31 | Chain link fabric fencing mesh of size 25x25 mm made of G.I. wire of dia 3 mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 400.0 | 400.0 | 18.36 | False | None | None | False | None | False | 7344.0 | 0 | 4070893 | 158377 | None | code32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 115.0 | 115.0 | 26.46 | False | None | None | False | None | False | 3042.9 | 0 | 4070894 | 158377 | None | code33 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 475.0 | 475.0 | 1.8 | False | None | None | False | None | False | 855.0 | 0 | 4070895 | 158377 | None | code34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 291.0 | 291.0 | 20.0 | False | None | None | False | None | False | 5820.0 | 0 |
| 1727242634000 | 0 | None | None | Buildings | ELECTRICAL WORK | 70048.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4070896 | 158378 | None | code01 | Open Conduit System : Supplying heavygaugePVCconduit pipe ....... dia .......mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , and fixing using inverted wood plugs in case of RCCceiling and RCC wall/ stone structure or rawl plugs incase of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 81.0 | 81.0 | 80.0 | False | None | None | False | None | False | 6480.0 | 0 | 4070897 | 158378 | None | code02 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction boxVolume 6 with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 56.0 | 56.0 | 50.0 | False | None | None | False | None | False | 2800.0 | 0 | 4070898 | 158378 | None | code03 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | 4070899 | 158378 | None | code04 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50HzAC supply& completely wired on existing box with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 646.0 | 646.0 | 2.0 | False | None | None | False | None | False | 1292.0 | 0 | 4070900 | 158378 | None | code05 | Supplying and drawing PVC insulated flexible copper wire of approved make as per IS: 694: 2010 23/0.0040" with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 22.0 | 22.0 | 100.0 | False | None | None | False | None | False | 2200.0 | 0 | 4070901 | 158378 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 | 4070902 | 158378 | None | code07 | Supplying 6A flush type socket and 6A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 128.0 | 128.0 | 30.0 | False | None | None | False | None | False | 3840.0 | 0 | 4070903 | 158378 | None | code08 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 4070904 | 158378 | None | code09 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable form ounting modular switch plates with due groove cutting in Brick/C.Cwall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 124.0 | 124.0 | 15.0 | False | None | None | False | None | False | 1860.0 | 0 | 4070905 | 158378 | None | code10 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 161.0 | 161.0 | 15.0 | False | None | None | False | None | False | 2415.0 | 0 | 4070906 | 158378 | None | code11 | Supplying PVC flexible conduit pipe ....mm dia fixing on surface over inverted tape red wooden plugs or phill plug sorrawl plugs and clamped using heavy gauges add lesatan interval of 300mm using NFscrews and on either end of the pipe terminated completely 20 mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | m | 19.0 | 19.0 | 50.0 | False | None | None | False | None | False | 950.0 | 0 | 4070907 | 158378 | None | code12 | Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 171.0 | 171.0 | 5.0 | False | None | None | False | None | False | 855.0 | 0 | 4070908 | 158378 | None | code13 | Supplying capacitor type ceiling fan complete with down rod blades,shackle ,canopies etc, for operation on 230V,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200 mm) Regular model with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 2984.0 | 2984.0 | 5.0 | False | None | None | False | None | False | 14920.0 | 0 | 4070909 | 158378 | None | code14 | Supplying of .....feet-PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz&Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 551.0 | 551.0 | 10.0 | False | None | None | False | None | False | 5510.0 | 0 | 4070910 | 158378 | None | code15 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 490.0 | 490.0 | 10.0 | False | None | None | False | None | False | 4900.0 | 0 | 4070911 | 158378 | None | code16 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED ofPower /COB with CCT6500 degree K, CRI70%. efficacy100 lumen per W,120degree beam spread , life25000 burning hours and Compliance to IS1 0322/IEC60598, LM79 & LM80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly. ,withPF0.95 ,power loss should5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit,THD less than 20% ,Life as per LM79.The operating input voltage should be between 130 to 275V. BIS Approved and Tested by NABL / CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6W with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 805.0 | 805.0 | 6.0 | False | None | None | False | None | False | 4830.0 | 0 | 4070912 | 158378 | None | code17 | Supplying & Fixing of 70-150 W lamp holder 2 Pin with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 | 4070913 | 158378 | None | code18 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x 400x 400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 4256.0 | 4256.0 | 1.0 | False | None | None | False | None | False | 4256.0 | 0 |
|
|
---|