createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727182787751
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1090000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-10-2024 16:00:00
tenderQueryClose08-10-2024 16:00:00
technicalBidOpen28-10-2024 16:00:00
publishedDate24-09-2024 19:35:18
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate09-10-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1727182787769
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT293
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Bettadapura(Anivalu) Village, Piriyapatana Taluk, Mysuru District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Bettadapura(Anivalu) Village, Piriyapatana Taluk, Mysuru District
categoryWORKS
categoryTextWorks
ecv72616021.58
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount72616022.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/522/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17271827880000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Bettadapura(Anivalu) Village, Piriyapatana Taluk, Mysuru District72616021.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4068299158297Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Comn-SR V-1, Item No - 1.12)Cum97.8597.85148.38FalseNoneNoneFalseNoneFalse14518.9830
4068300158297Nonecode02Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -I Material (Comn-SR V-3, Item No - 4.1 (I) )Cum2562.642562.64184.34FalseNoneNoneFalseNoneFalse472397.05760
4068301158297Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dessing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m .(Comn-SR V-1, Item No - 1.14.1)Cum105.06105.06944.93FalseNoneNoneFalseNoneFalse99274.34580
4068302158297Nonecode04Earth work excavation for Foundation by mechanical means for In ordinary/soft rock without blasting upto 1.5 m depth, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dessing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth .(Comn-SR V-1, Item No - 1.15.1)Cum373.89373.89230.43FalseNoneNoneFalseNoneFalse86155.47270
4068303158297Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Comn-SR V-1, Item No - 1.9)Cum273.98273.98269.94FalseNoneNoneFalseNoneFalse73958.16120
4068304158297Nonecode06Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Comn-SR V-1, Item No - 1.11)Cum445.99445.99462.03FalseNoneNoneFalseNoneFalse206060.75970
4068305158297Nonecode07Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. (Comn-SR V-2, Item No - 4.1)Sqm121.54121.54568.51FalseNoneNoneFalseNoneFalse69096.70540
4068306158297Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (7.5) Using 40 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.2)Cum5833.925833.92198.1672FalseNoneNoneFalseNoneFalse1156091.5914240
4068307158297Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.2.2.1) For RCC Column Footing - Add shuttering, cost-8% :Cum7048.177048.17373.81FalseNoneNoneFalseNoneFalse2634676.42770
4068308158297Nonecode10Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)- Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.3.2) - Plinth Beam - Add shuttering, cost-50% :Cum10011.610011.670.49FalseNoneNoneFalseNoneFalse705717.6840
4068309158297Nonecode11Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.3.2) For Curtain Wall ( Retaining Wall )Cum7341.847341.844.62FalseNoneNoneFalseNoneFalse33919.30080
4068310158297Nonecode12Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.3.2) Flagging ConcreteCum6674.46674.418.8FalseNoneNoneFalseNoneFalse125478.720
4068311158297Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : a. Upto Plinth Lvl and b. Ground floor - Add shuttering, cost-70% :Cum11982.0911982.0952.38FalseNoneNoneFalseNoneFalse627621.87420
4068312158297Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : First floor - Add shuttering, cost-70% :Cum12101.9112101.9118.59FalseNoneNoneFalseNoneFalse224974.50690
4068313158297Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : Second floor - Add shuttering, cost-70%Cum12221.7312221.7318.59FalseNoneNoneFalseNoneFalse227201.96070
4068314158297Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : Third floor - Add shuttering, cost-70% :Cum12341.5612341.5618.59FalseNoneNoneFalseNoneFalse229429.60040
4068315158297Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : Fourth floor - Add shuttering, cost-70% :Cum12461.3812461.3818.59FalseNoneNoneFalseNoneFalse231657.05420
4068316158297Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : Fifth floor - Add shuttering, cost-70% :Cum12581.212581.27.38FalseNoneNoneFalseNoneFalse92849.2560
4068317158297Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Lintel beam : a. Ground floor - Add shuttering, cost-60% :Cum11277.2611277.265.66FalseNoneNoneFalseNoneFalse63829.29160
4068318158297Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : First floor - Add shuttering, cost-60% :Cum11390.0411390.049.58FalseNoneNoneFalseNoneFalse109116.58320
4068319158297Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : Second floor - Add shuttering, cost-60% :Cum11502.8111502.819.58FalseNoneNoneFalseNoneFalse110196.91980
4068320158297Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : Third floor - Add shuttering, cost-60% :Cum11615.5811615.589.58FalseNoneNoneFalseNoneFalse111277.25640
4068321158297Nonecode23Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2 For RCC Lintel : Fourth floor - Add shuttering, cost-60% :Cum11728.3511728.359.58FalseNoneNoneFalseNoneFalse112357.5930
4068322158297Nonecode24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Roof beam : a. Ground floor - Add shuttering, cost-60% :Cum11277.2611277.2639.31FalseNoneNoneFalseNoneFalse443309.09060
4068323158297Nonecode25Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : First floor - Add shuttering, cost-60% :Cum11390.0411390.0439.31FalseNoneNoneFalseNoneFalse447742.47240
4068324158297Nonecode26Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Second floor - Add shuttering, cost-60% :Cum11502.8111502.8139.31FalseNoneNoneFalseNoneFalse452175.46110
4068325158297Nonecode27Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Third floor - Add shuttering, cost-60% :Cum11615.5811615.5839.31FalseNoneNoneFalseNoneFalse456608.44980
4068326158297Nonecode28Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Fourth floor - Add shuttering, cost-60% :Cum11728.3511728.3539.31FalseNoneNoneFalseNoneFalse461041.43850
4068327158297Nonecode29Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Fifth floor - Add shuttering, cost-60% :Cum11841.1311841.135.65FalseNoneNoneFalseNoneFalse66902.38450
4068328158297Nonecode30Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Roof Slab : a. Ground floor - Add shuttering, cost-50% :Cum10572.4410572.4491.98FalseNoneNoneFalseNoneFalse972453.03120
4068329158297Nonecode31Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : First floor - Add shuttering, cost-50% :Cum10678.1610678.1689.21FalseNoneNoneFalseNoneFalse952598.65360
4068330158297Nonecode32Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Second floor - Add shuttering, cost-50% :Cum10783.8810783.8889.21FalseNoneNoneFalseNoneFalse962029.93480
4068331158297Nonecode33Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Third floor - Add shuttering, cost-50% :Cum10889.6110889.6189.21FalseNoneNoneFalseNoneFalse971462.10810
4068332158297Nonecode34Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Fourth floor - Add shuttering, cost-50% :Cum10995.3310995.3389.21FalseNoneNoneFalseNoneFalse980893.38930
4068333158297Nonecode35Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Fifth floor - Add shuttering, cost-50% :Cum11101.0611101.068.06FalseNoneNoneFalseNoneFalse89474.54360
4068334158297Nonecode36Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Staircase : a. Ground floor to First floor - Add shuttering, cost-50% :Cum10572.4410572.445.35FalseNoneNoneFalseNoneFalse56562.5540
4068335158297Nonecode37Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : First floor to Second floor - Add shuttering, cost-50% :Cum10678.1610678.165.0FalseNoneNoneFalseNoneFalse53390.80
4068336158297Nonecode38Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Second floor to Third floor - Add shuttering, cost-50% :Cum10783.8810783.885.0FalseNoneNoneFalseNoneFalse53919.40
4068337158297Nonecode39Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Third floor to Fourth floor - Add shuttering, cost-50% :Cum10889.6110889.615.0FalseNoneNoneFalseNoneFalse54448.050
4068338158297Nonecode40Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Fourth floor to Fifth (Terrace) floor - Add shuttering, cost-50% :Cum10995.3310995.335.0FalseNoneNoneFalseNoneFalse54976.650
4068339158297Nonecode41Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Chejja's & Sill : a. Ground floor - Add shuttering, cost-45% :Cum10220.0210220.025.68FalseNoneNoneFalseNoneFalse58049.71360
4068340158297Nonecode42Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : First floor - Add shuttering, cost-45% :Cum10322.2210322.225.2FalseNoneNoneFalseNoneFalse53675.5440
4068341158297Nonecode43Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : Second floor - Add shuttering, cost-45% :Cum10424.4210424.425.2FalseNoneNoneFalseNoneFalse54206.9840
4068342158297Nonecode44Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Chejja's & Sill : Third floor - Add shuttering, cost-45% :Cum10526.6210526.625.2FalseNoneNoneFalseNoneFalse54738.4240
4068343158297Nonecode45Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : Fourth floor - Add shuttering, cost-45% :Cum10628.8210628.825.2FalseNoneNoneFalseNoneFalse55269.8640
4068344158297Nonecode46Extra for providing throating or drip moulding to RCC Chejja with plastering ( Labour charge only ) as per Specification. ( SR 2018, P-16, Item No - 4.21 ) ground floorMtr33.033.0147.5FalseNoneNoneFalseNoneFalse4867.50
4068345158297Nonecode47Extra for providing throating or drip moulding to RCC Chejja with plastering ( Labour charge only ) as per Specification. ( SR 2018, P-16, Item No - 4.21 ) first floorMtr38.038.0132.2FalseNoneNoneFalseNoneFalse5023.60
4068346158297Nonecode48Extra for providing throating or drip moulding to RCC Chejja with plastering ( Labour charge only ) as per Specification. ( SR 2018, P-16, Item No - 4.21 ) second floorMtr43.043.0132.2FalseNoneNoneFalseNoneFalse5684.60
4068347158297Nonecode49Extra for providing throating or drip moulding to RCC Chejja with plastering ( Labour charge only ) as per Specification. ( SR 2018, P-16, Item No - 4.21 ) third floorMtr48.048.0132.2FalseNoneNoneFalseNoneFalse6345.60
4068348158297Nonecode50Extra for providing throating or drip moulding to RCC Chejja with plastering ( Labour charge only ) as per Specification. ( SR 2018, P-16, Item No - 4.21 ) fourth floorMtr53.053.0132.2FalseNoneNoneFalseNoneFalse7006.60
4068349158297Nonecode51Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a) a. Ground floorTonne92140.7192140.7175.94FalseNoneNoneFalseNoneFalse6997165.51740
4068350158297Nonecode52Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a) First FloorTonne93062.1293062.1223.02FalseNoneNoneFalseNoneFalse2142290.00240
4068351158297Nonecode53Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Second FloorTonne93983.5293983.5223.02FalseNoneNoneFalseNoneFalse2163500.63040
4068352158297Nonecode54Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Third FloorTonne94904.9394904.9323.02FalseNoneNoneFalseNoneFalse2184711.48860
4068353158297Nonecode55Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Fourth FloorTonne95826.3495826.3423.02FalseNoneNoneFalseNoneFalse2205922.34680
4068354158297Nonecode56Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Fifth Floor or Terrace FloorTonne96747.7596747.753.76FalseNoneNoneFalseNoneFalse363771.540
4068355158297Nonecode57Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator Sill : a. Ground floor - Add shuttering, cost-45% :Cum10245.6210245.621.15FalseNoneNoneFalseNoneFalse11782.4630
4068356158297Nonecode58Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : First floor - Add shuttering, cost-45% :Cum10348.0710348.071.08FalseNoneNoneFalseNoneFalse11175.91560
4068357158297Nonecode59Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Second floor - Add shuttering, cost-45% :Cum10450.5310450.531.08FalseNoneNoneFalseNoneFalse11286.57240
4068358158297Nonecode60Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Third floor - Add shuttering, cost-45% :Cum10552.9810552.981.08FalseNoneNoneFalseNoneFalse11397.21840
4068359158297Nonecode61Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Fourth floor - Add shuttering, cost-45% :Cum10655.4410655.441.08FalseNoneNoneFalseNoneFalse11507.87520
4068360158297Nonecode62Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) a. Ground floorSqm1349.31349.3220.64FalseNoneNoneFalseNoneFalse297709.5520
4068361158297Nonecode63Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) First FloorSqm1362.791362.79194.76FalseNoneNoneFalseNoneFalse265416.98040
4068362158297Nonecode64Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Second FloorSqm1376.291376.29194.76FalseNoneNoneFalseNoneFalse268046.24040
4068363158297Nonecode65Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Third FloorSqm1389.781389.78194.76FalseNoneNoneFalseNoneFalse270673.55280
4068364158297Nonecode66Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32)Fourth FloorSqm1403.271403.27194.76FalseNoneNoneFalseNoneFalse273300.86520
4068365158297Nonecode67Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Fifth Floor or Terrace FloorSqm1416.771416.77141.24FalseNoneNoneFalseNoneFalse200104.59480
4068366158297Nonecode68Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33) a. Ground floorSqm1267.931267.93209.41FalseNoneNoneFalseNoneFalse265517.22130
4068367158297Nonecode69Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33) First FloorSqm1280.611280.61316.02FalseNoneNoneFalseNoneFalse404698.37220
4068368158297Nonecode70Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Second FloorSqm1293.291293.29316.02FalseNoneNoneFalseNoneFalse408705.50580
4068369158297Nonecode71Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Third FloorSqm1305.971305.97316.02FalseNoneNoneFalseNoneFalse412712.63940
4068370158297Nonecode72Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Fourth FloorSqm1318.651318.65316.02FalseNoneNoneFalseNoneFalse416719.7730
4068371158297Nonecode73Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34) a. Ground floorSqm1137.121137.1276.09FalseNoneNoneFalseNoneFalse86523.46080
4068372158297Nonecode74Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)First FloorSqm1148.491148.4960.94FalseNoneNoneFalseNoneFalse69988.98060
4068373158297Nonecode75Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)Second FloorSqm1159.861159.8660.94FalseNoneNoneFalseNoneFalse70681.86840
4068374158297Nonecode76Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)Third FloorSqm1171.231171.2360.94FalseNoneNoneFalseNoneFalse71374.75620
4068375158297Nonecode77Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34) Fourth FloorSqm1182.61182.660.94FalseNoneNoneFalseNoneFalse72067.6440
4068376158297Nonecode78Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) a. Ground floorCum101779.45101779.451.14FalseNoneNoneFalseNoneFalse116028.5730
4068377158297Nonecode79Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) First FloorCum102797.24102797.241.01FalseNoneNoneFalseNoneFalse103825.21240
4068378158297Nonecode80Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Second FloorCum103815.04103815.041.01FalseNoneNoneFalseNoneFalse104853.19040
4068379158297Nonecode81Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Third FloorCum104832.83104832.831.01FalseNoneNoneFalseNoneFalse105881.15830
4068380158297Nonecode82Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Fourth FloorCum105850.63105850.631.01FalseNoneNoneFalseNoneFalse106909.13630
4068381158297Nonecode83Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Fifth FloorCum106868.42106868.420.08FalseNoneNoneFalseNoneFalse8549.47360
4068382158297Nonecode84Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) a. Ground floorNos1046.481046.4810.0FalseNoneNoneFalseNoneFalse10464.80
4068383158297Nonecode85Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) First FloorNos1056.941056.9413.0FalseNoneNoneFalseNoneFalse13740.220
4068384158297Nonecode86Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Second FloorNos1067.411067.4113.0FalseNoneNoneFalseNoneFalse13876.330
4068385158297Nonecode87Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Third FloorNos1077.871077.8713.0FalseNoneNoneFalseNoneFalse14012.310
4068386158297Nonecode88Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51)Fourth FloorNos1088.341088.3413.0FalseNoneNoneFalseNoneFalse14148.420
4068387158297Nonecode89Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Fifth FloorNos1098.81098.81.0FalseNoneNoneFalseNoneFalse1098.80
4068388158297Nonecode90Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) a. Ground floorSqm5108.85108.833.6FalseNoneNoneFalseNoneFalse171655.680
4068389158297Nonecode91Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) First FloorSqm5159.895159.8931.2FalseNoneNoneFalseNoneFalse160988.5680
4068390158297Nonecode92Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Second FloorSqm5210.985210.9831.2FalseNoneNoneFalseNoneFalse162582.5760
4068391158297Nonecode93Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Third FloorSqm5262.065262.0631.2FalseNoneNoneFalseNoneFalse164176.2720
4068392158297Nonecode94Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Fourth FloorSqm5313.155313.1531.2FalseNoneNoneFalseNoneFalse165770.280
4068393158297Nonecode95Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Fifth FloorSqm5364.245364.242.4FalseNoneNoneFalseNoneFalse12874.1760
4068394158297Nonecode96Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) a. Ground floorm723.06723.0625.05FalseNoneNoneFalseNoneFalse18112.6530
4068395158297Nonecode97Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) First Floorm730.29730.2999.0FalseNoneNoneFalseNoneFalse72298.710
4068396158297Nonecode98Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Second Floorm737.52737.5299.0FalseNoneNoneFalseNoneFalse73014.480
4068397158297Nonecode99Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Third Floorm744.75744.7599.0FalseNoneNoneFalseNoneFalse73730.250
4068398158297Nonecode100Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Fourth Floorm751.98751.9899.0FalseNoneNoneFalseNoneFalse74446.020
4068399158297Nonecode101Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) a. Ground floorSqm3589.553589.558.51FalseNoneNoneFalseNoneFalse30547.07050
4068400158297Nonecode102Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) First FloorSqm3625.453625.4531.5FalseNoneNoneFalseNoneFalse114201.6750
4068401158297Nonecode103Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Second FloorSqm3661.343661.3431.5FalseNoneNoneFalseNoneFalse115332.210
4068402158297Nonecode104Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Third FloorSqm3697.243697.2431.5FalseNoneNoneFalseNoneFalse116463.060
4068403158297Nonecode105Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Fourth FloorSqm3733.133733.1331.5FalseNoneNoneFalseNoneFalse117593.5950
4068404158297Nonecode106Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) a. Ground floorSqm6936.026936.0256.7FalseNoneNoneFalseNoneFalse393272.3340
4068405158297Nonecode107Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) First FloorSqm7005.387005.3837.8FalseNoneNoneFalseNoneFalse264803.3640
4068406158297Nonecode108Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Second FloorSqm7074.747074.7437.8FalseNoneNoneFalseNoneFalse267425.1720
4068407158297Nonecode109Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Third FloorSqm7144.17144.137.8FalseNoneNoneFalseNoneFalse270046.980
4068408158297Nonecode110Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Fourth FloorSqm7213.467213.4637.8FalseNoneNoneFalseNoneFalse272668.7880
4068409158297Nonecode111Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) a. Ground floorSqm5890.575890.570.9FalseNoneNoneFalseNoneFalse5301.5130
4068410158297Nonecode112Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) First FloorSqm5949.485949.4819.62FalseNoneNoneFalseNoneFalse116728.79760
4068411158297Nonecode113Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Second FloorSqm6008.386008.3819.62FalseNoneNoneFalseNoneFalse117884.41560
4068412158297Nonecode114Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Third FloorSqm6067.296067.2919.62FalseNoneNoneFalseNoneFalse119040.22980
4068413158297Nonecode115Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Fourth FloorSqm6126.196126.1919.62FalseNoneNoneFalseNoneFalse120195.84780
4068414158297Nonecode116Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) a. Ground floorKgs173.04173.041209.6FalseNoneNoneFalseNoneFalse209309.1840
4068415158297Nonecode117Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) First FloorKgs174.77174.771205.82FalseNoneNoneFalseNoneFalse210741.16140
4068416158297Nonecode118Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Second FloorKgs176.5176.51205.82FalseNoneNoneFalseNoneFalse212827.230
4068417158297Nonecode119Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Third FloorKgs178.23178.231205.82FalseNoneNoneFalseNoneFalse214913.29860
4068418158297Nonecode120Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Fourth FloorKgs179.96179.961205.82FalseNoneNoneFalseNoneFalse216999.36720
4068419158297Nonecode121Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.. (Comn-SR V-2, Item No -11.5.1) Main Door Grill GateSqm4612.344612.345.76FalseNoneNoneFalseNoneFalse26567.07840
4068420158297Nonecode122Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) a. Ground floorKgs581.95581.95142.64FalseNoneNoneFalseNoneFalse83009.3480
4068421158297Nonecode123Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) First FloorKgs587.77587.7782.12FalseNoneNoneFalseNoneFalse48267.67240
4068422158297Nonecode124Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Second FloorKgs593.59593.5982.12FalseNoneNoneFalseNoneFalse48745.61080
4068423158297Nonecode125Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Third FloorKgs599.41599.4182.12FalseNoneNoneFalseNoneFalse49223.54920
4068424158297Nonecode126Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Fourth FloorKgs605.23605.2382.12FalseNoneNoneFalseNoneFalse49701.48760
4068425158297Nonecode127Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) For Ceiling a. Ground floorSqm262.65262.65490.3FalseNoneNoneFalseNoneFalse128777.2950
4068426158297Nonecode128Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) First FloorSqm265.28265.28471.82FalseNoneNoneFalseNoneFalse125164.40960
4068427158297Nonecode129Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Second FloorSqm267.9267.9471.82FalseNoneNoneFalseNoneFalse126400.5780
4068428158297Nonecode130Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Third FloorSqm270.53270.53471.82FalseNoneNoneFalseNoneFalse127641.46460
4068429158297Nonecode131Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Fourth FloorSqm273.16273.16471.82FalseNoneNoneFalseNoneFalse128882.35120
4068430158297Nonecode132Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Fifth FloorSqm275.78275.7850.11FalseNoneNoneFalseNoneFalse13819.33580
4068431158297Nonecode133Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall a. Ground floorSqm287.37287.371026.28FalseNoneNoneFalseNoneFalse294922.08360
4068432158297Nonecode134Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall First FloorSqm290.24290.241561.26FalseNoneNoneFalseNoneFalse453140.10240
4068433158297Nonecode135Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wallSecond FloorSqm293.12293.121561.26FalseNoneNoneFalseNoneFalse457636.53120
4068434158297Nonecode136Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Third FloorSqm295.99295.991561.26FalseNoneNoneFalseNoneFalse462117.34740
4068435158297Nonecode137Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Fourth FloorSqm298.86298.861561.26FalseNoneNoneFalseNoneFalse466598.16360
4068436158297Nonecode138Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Fifth FloorSqm301.74301.7481.88FalseNoneNoneFalseNoneFalse24706.47120
4068437158297Nonecode139Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) ground floorMtr39.1439.14102.75FalseNoneNoneFalseNoneFalse4021.6350
4068438158297Nonecode140Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) first floorMtr39.5339.53620.45FalseNoneNoneFalseNoneFalse24526.38850
4068439158297Nonecode141Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) second floorMtr39.9239.92620.45FalseNoneNoneFalseNoneFalse24768.3640
4068440158297Nonecode142Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) third floorMtr40.3140.31620.45FalseNoneNoneFalseNoneFalse25010.33950
4068441158297Nonecode143Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) fourth floorMtr40.7140.71620.45FalseNoneNoneFalseNoneFalse25258.51950
4068442158297Nonecode144Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) (Comn-SR V-2, Item No -8.16.2) fifth floorMtr41.141.179.4FalseNoneNoneFalseNoneFalse3263.340
4068443158297Nonecode145Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) a. Ground floorSqm103.0103.01516.58FalseNoneNoneFalseNoneFalse156207.740
4068444158297Nonecode146Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) First FloorSqm104.03104.032033.08FalseNoneNoneFalseNoneFalse211501.31240
4068445158297Nonecode147Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Second FloorSqm105.06105.062033.08FalseNoneNoneFalseNoneFalse213595.38480
4068446158297Nonecode148Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Third FloorSqm106.09106.092033.08FalseNoneNoneFalseNoneFalse215689.45720
4068447158297Nonecode149Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Fourth FloorSqm107.12107.122033.08FalseNoneNoneFalseNoneFalse217783.52960
4068448158297Nonecode150Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Fifth FloorSqm108.15108.15131.99FalseNoneNoneFalseNoneFalse14274.71850
4068449158297Nonecode151Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall a. Ground floorSqm396.55396.55564.36FalseNoneNoneFalseNoneFalse223796.9580
4068450158297Nonecode152Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall First FloorSqm400.52400.52585.48FalseNoneNoneFalseNoneFalse234496.44960
4068451158297Nonecode153Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Second FloorSqm404.48404.48585.48FalseNoneNoneFalseNoneFalse236814.95040
4068452158297Nonecode154Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Third FloorSqm408.45408.45585.48FalseNoneNoneFalseNoneFalse239139.3060
4068453158297Nonecode155Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Fourth FloorSqm412.41412.41585.48FalseNoneNoneFalseNoneFalse241457.80680
4068454158297Nonecode156Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Fifth FloorSqm416.38416.38446.65FalseNoneNoneFalseNoneFalse185976.1270
4068455158297Nonecode157Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) ground floorSqm162.74162.741516.58FalseNoneNoneFalseNoneFalse246808.22920
4068456158297Nonecode158Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) first floorSqm164.37164.372033.08FalseNoneNoneFalseNoneFalse334177.35960
4068457158297Nonecode159Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) second floorSqm165.99165.992033.08FalseNoneNoneFalseNoneFalse337470.94920
4068458158297Nonecode160Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) third floorSqm167.62167.622033.08FalseNoneNoneFalseNoneFalse340784.86960
4068459158297Nonecode161Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) fourth floorSqm169.25169.252033.08FalseNoneNoneFalseNoneFalse344098.790
4068460158297Nonecode162Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) fifth floorSqm170.88170.88131.99FalseNoneNoneFalseNoneFalse22554.45120
4068461158297Nonecode163Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) ground floorSqm54.5954.59564.36FalseNoneNoneFalseNoneFalse30808.41240
4068462158297Nonecode164Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) first floorSqm55.1455.14585.48FalseNoneNoneFalseNoneFalse32283.36720
4068463158297Nonecode165Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) second floorSqm55.6855.68585.48FalseNoneNoneFalseNoneFalse32599.52640
4068464158297Nonecode166Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) third floorSqm56.2356.23585.48FalseNoneNoneFalseNoneFalse32921.54040
4068465158297Nonecode167Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) fourth floorSqm56.7756.77585.48FalseNoneNoneFalseNoneFalse33237.69960
4068466158297Nonecode168Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) fifth floorSqm57.3257.32446.65FalseNoneNoneFalseNoneFalse25601.9780
4068467158297Nonecode169Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ ground floorSqm179.22179.22564.36FalseNoneNoneFalseNoneFalse101144.59920
4068468158297Nonecode170Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) : @ first floorSqm181.01181.01585.48FalseNoneNoneFalseNoneFalse105977.73480
4068469158297Nonecode171Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ second floorSqm182.8182.8585.48FalseNoneNoneFalseNoneFalse107025.7440
4068470158297Nonecode172Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ third floorSqm184.6184.6585.48FalseNoneNoneFalseNoneFalse108079.6080
4068471158297Nonecode173Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ fourth floorSqm186.39186.39585.48FalseNoneNoneFalseNoneFalse109127.61720
4068472158297Nonecode174Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ fifth floorSqm188.18188.18446.65FalseNoneNoneFalseNoneFalse84050.5970
4068473158297Nonecode175Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ ground floorSqm118.45118.45115.2FalseNoneNoneFalseNoneFalse13645.440
4068474158297Nonecode176Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ first floorSqm119.63119.63114.84FalseNoneNoneFalseNoneFalse13738.30920
4068475158297Nonecode177Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ second floorSqm120.82120.82114.84FalseNoneNoneFalseNoneFalse13874.96880
4068476158297Nonecode178Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ third floorSqm122.0122.0114.84FalseNoneNoneFalseNoneFalse14010.480
4068477158297Nonecode179Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ fourth floorSqm123.19123.19114.84FalseNoneNoneFalseNoneFalse14147.13960
4068478158297Nonecode180Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ ground floorSqm2539.982539.98394.36FalseNoneNoneFalseNoneFalse1001666.51280
4068479158297Nonecode181Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ first floorSqm2565.382565.38115.08FalseNoneNoneFalseNoneFalse295223.93040
4068480158297Nonecode182Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ second floorSqm2590.782590.78115.08FalseNoneNoneFalseNoneFalse298146.96240
4068481158297Nonecode183Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ third floorSqm2616.182616.18115.08FalseNoneNoneFalseNoneFalse301069.99440
4068482158297Nonecode184Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ fourth floorSqm2641.582641.58115.08FalseNoneNoneFalseNoneFalse303993.02640
4068483158297Nonecode185Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ ground floorSqm1179.351179.35136.02FalseNoneNoneFalseNoneFalse160415.1870
4068484158297Nonecode186Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ first floorSqm1191.141191.14311.87FalseNoneNoneFalseNoneFalse371480.83180
4068485158297Nonecode187Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ second floorSqm1202.941202.94311.87FalseNoneNoneFalseNoneFalse375160.89780
4068486158297Nonecode188Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ third floorSqm1214.731214.73311.87FalseNoneNoneFalseNoneFalse378837.84510
4068487158297Nonecode189Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ fourth floorSqm1226.521226.52311.87FalseNoneNoneFalseNoneFalse382514.79240
4068488158297Nonecode190Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ ground floorSqm915.67915.6728.04FalseNoneNoneFalseNoneFalse25675.38680
4068489158297Nonecode191Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ first floorSqm924.83924.8394.5FalseNoneNoneFalseNoneFalse87396.4350
4068490158297Nonecode192Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ second floorSqm933.98933.9894.5FalseNoneNoneFalseNoneFalse88261.110
4068491158297Nonecode193Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ third floorSqm943.14943.1494.5FalseNoneNoneFalseNoneFalse89126.730
4068492158297Nonecode194Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ fourth floorSqm952.3952.394.5FalseNoneNoneFalseNoneFalse89992.350
4068493158297Nonecode195Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Rough Plastering For Bath & WC Walls : ground floorSqm287.37287.3764.37FalseNoneNoneFalseNoneFalse18498.00690
4068494158297Nonecode196Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Rough Plastering For Bath & WC Walls : first floorSqm290.24290.24264.39FalseNoneNoneFalseNoneFalse76736.55360
4068495158297Nonecode197Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Rough Plastering For Bath & WC Walls : second floorSqm293.12293.12264.39FalseNoneNoneFalseNoneFalse77497.99680
4068496158297Nonecode198Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Rough Plastering For Bath & WC Walls : third floorSqm295.99295.99264.39FalseNoneNoneFalseNoneFalse78256.79610
4068497158297Nonecode199Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Rough Plastering For Bath & WC Walls : fourth floorSqm298.86298.86264.39FalseNoneNoneFalseNoneFalse79015.59540
4068498158297Nonecode200Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ ground floorSqm1139.181139.1847.99FalseNoneNoneFalseNoneFalse54669.24820
4068499158297Nonecode201Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ first floorSqm1150.571150.57264.39FalseNoneNoneFalseNoneFalse304199.20230
4068500158297Nonecode202Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ second floorSqm1161.961161.96264.39FalseNoneNoneFalseNoneFalse307210.60440
4068501158297Nonecode203Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ third floorSqm1173.361173.36264.39FalseNoneNoneFalseNoneFalse310224.65040
4068502158297Nonecode204Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ fourth floorSqm1184.751184.75264.39FalseNoneNoneFalseNoneFalse313236.05250
4068503158297Nonecode205Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm849.93849.9353.98FalseNoneNoneFalseNoneFalse45879.22140
4068504158297Nonecode206Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ second floor levelSqm858.34858.3453.98FalseNoneNoneFalseNoneFalse46333.19320
4068505158297Nonecode207Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ third floor levelSqm866.76866.7653.98FalseNoneNoneFalseNoneFalse46787.70480
4068506158297Nonecode208Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ fourth floor levelSqm875.17875.1753.98FalseNoneNoneFalseNoneFalse47241.67660
4068507158297Nonecode209Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ fifth floor levelSqm883.59883.59532.54FalseNoneNoneFalseNoneFalse470547.01860
4068508158297Nonecode210Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : .(Comn-SR V-2, Item No - 12.74.1) 125x64x1.90mm For Toilet doors onlyEach105.06105.06264.0FalseNoneNoneFalseNoneFalse27735.840
4068509158297Nonecode211Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Comn-SR V-2, Item No - 12.72)Each84.4684.46132.0FalseNoneNoneFalseNoneFalse11148.720
4068510158297Nonecode212Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Comn-SR V-2, Item No - 12.73.1)Each45.3245.32132.0FalseNoneNoneFalseNoneFalse5982.240
4068511158297Nonecode213Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(Comn-SR V-2, Item No - 12.60)Each1083.561083.56132.0FalseNoneNoneFalseNoneFalse143029.920
4068512158297Nonecode214Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) first floorCum2098.292098.2927.35FalseNoneNoneFalseNoneFalse57388.23150
4068513158297Nonecode215Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) second floorCum2119.062119.0627.35FalseNoneNoneFalseNoneFalse57956.2910
4068514158297Nonecode216Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) third floorCum2139.842139.8427.35FalseNoneNoneFalseNoneFalse58524.6240
4068515158297Nonecode217Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) fourth floorCum2160.612160.6127.35FalseNoneNoneFalseNoneFalse59092.68350
4068516158297Nonecode218Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. first floorCum6897.196897.196.84FalseNoneNoneFalseNoneFalse47176.77960
4068517158297Nonecode219Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. second floorCum6965.486965.486.84FalseNoneNoneFalseNoneFalse47643.88320
4068518158297Nonecode220Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. third floorCum7033.777033.776.84FalseNoneNoneFalseNoneFalse48110.98680
4068519158297Nonecode221Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Comn-SR V-2, Item No -7.18 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. fouth floorCum7102.067102.066.84FalseNoneNoneFalseNoneFalse48578.09040
4068520158297Nonecode222Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. (Comn-SR V-2, Item No -8.80 ) ground floorMtr67.9867.98165.6FalseNoneNoneFalseNoneFalse11257.4880
4068521158297Nonecode223Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. (Comn-SR V-2, Item No -8.80 ) first floorMtr68.6668.66151.8FalseNoneNoneFalseNoneFalse10422.5880
4068522158297Nonecode224Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. (Comn-SR V-2, Item No -8.80 ) second floorMtr69.3469.34151.8FalseNoneNoneFalseNoneFalse10525.8120
4068523158297Nonecode225Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. (Comn-SR V-2, Item No -8.80 ) third floorMtr70.0270.02151.8FalseNoneNoneFalseNoneFalse10629.0360
4068524158297Nonecode226Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. (Comn-SR V-2, Item No -8.80 ) fourth floorMtr70.770.7151.8FalseNoneNoneFalseNoneFalse10732.260
4068525158297Nonecode227Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, , including cost of materials, mortar, labour, curing complete as per specifications. (Comn-SR V-2, Item No -9.27 )Nos2459.642459.642.25FalseNoneNoneFalseNoneFalse5534.190
4068526158297Nonecode228Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) for all floorsEach2951.982951.9865.0FalseNoneNoneFalseNoneFalse191878.70
4068527158297Nonecode229Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete.(Comn-SR V-2, Item No - 14.44) all floorsEach11560.7211560.725.0FalseNoneNoneFalseNoneFalse57803.60
4068528158297Nonecode230Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(Comn-SR V-2, Item No - 14.1.1)Each5030.525030.5240.0FalseNoneNoneFalseNoneFalse201220.80
4068529158297Nonecode231Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. (Market Rate) all floorsNos3000.03000.061.0FalseNoneNoneFalseNoneFalse183000.00
4068530158297Nonecode232Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class (Comn-SR V-2, Item No - 14.60.a) EconomyNos4104.554104.5542.0FalseNoneNoneFalseNoneFalse172391.10
4068531158297Nonecode233Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (Comn-SR V-2, Item No - 13.12)Nos654.05654.0550.0FalseNoneNoneFalseNoneFalse32702.50
4068532158297Nonecode234Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(Comn-SR V-2, Item No - 13.15)Nos746.75746.75203.0FalseNoneNoneFalseNoneFalse151590.250
4068533158297Nonecode235Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31)Each1256.61256.665.0FalseNoneNoneFalseNoneFalse81679.00
4068534158297Nonecode236Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class(Comn-SR V-2, Item No - 14.92a) EconomyNos739.54739.5465.0FalseNoneNoneFalseNoneFalse48070.10
4068535158297Nonecode237Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.(Comn-SR V-2, Item No - 14.10)Each5786.545786.542.0FalseNoneNoneFalseNoneFalse11573.080
4068536158297Nonecode238Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangementsv& all necessary accesories complete - Class (Comn-SR V-2, Item No - 14.62a)EconomyNos1985.841985.842.0FalseNoneNoneFalseNoneFalse3971.680
4068537158297Nonecode239600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2)Each510.88510.8842.0FalseNoneNoneFalseNoneFalse21456.960
4068538158297Nonecode240Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28)Each94.7694.7665.0FalseNoneNoneFalseNoneFalse6159.40
4068539158297Nonecode241Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1.7)Mtr423.33423.33250.0FalseNoneNoneFalseNoneFalse105832.50
4068540158297Nonecode242Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8.8)Each176.13176.1350.0FalseNoneNoneFalseNoneFalse8806.50
4068541158297Nonecode243Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9.8)Each311.06311.0650.0FalseNoneNoneFalseNoneFalse15553.00
4068542158297Nonecode244Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8)Each258.53258.5350.0FalseNoneNoneFalseNoneFalse12926.50
4068543158297Nonecode245Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 160 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.9)Mtr636.54636.54180.0FalseNoneNoneFalseNoneFalse114577.20
4068544158297Nonecode246Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 160mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8)Each345.05345.0540.0FalseNoneNoneFalseNoneFalse13802.00
4068545158297Nonecode247Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 160mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8)Each485.13485.1340.0FalseNoneNoneFalseNoneFalse19405.20
4068546158297Nonecode248Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 160mm dia PVC Tee (Comn-SR V-5, Item No -10.10.10)Each479.98479.9840.0FalseNoneNoneFalseNoneFalse19199.20
4068547158297Nonecode249Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Comn-SR V-2, Item No - 13.63)Each251.32251.32145.0FalseNoneNoneFalseNoneFalse36441.40
4068548158297Nonecode250Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid. (Comn-SR V-2, Item No - 13.22.2)Nos208.06208.06145.0FalseNoneNoneFalseNoneFalse30168.70
4068549158297Nonecode251Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia(MR)Nos720.0720.0100.0FalseNoneNoneFalseNoneFalse72000.00
4068550158297Nonecode252Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2)Mtr390.37390.37375.0FalseNoneNoneFalseNoneFalse146388.750
4068551158297Nonecode253Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc., 25mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3)Mtr491.31491.31170.0FalseNoneNoneFalseNoneFalse83522.70
4068552158297Nonecode254Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 20mm nominal bore(Comn-SR V-2, Item No - 13.5.2)Mtr323.42323.424.0FalseNoneNoneFalseNoneFalse1293.680
4068553158297Nonecode255Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3)Mtr341.96341.9620.0FalseNoneNoneFalseNoneFalse6839.20
4068554158297Nonecode256Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2)Mtr223.51223.51200.0FalseNoneNoneFalseNoneFalse44702.00
4068555158297Nonecode257Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3)Mtr304.88304.88131.0FalseNoneNoneFalseNoneFalse39939.280
4068556158297Nonecode258Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4)Mtr383.16383.16298.0FalseNoneNoneFalseNoneFalse114181.680
4068557158297Nonecode259Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 40 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.5)Mtr491.31491.3172.0FalseNoneNoneFalseNoneFalse35374.320
4068558158297Nonecode260Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 50 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.6)Mtr742.63742.63120.0FalseNoneNoneFalseNoneFalse89115.60
4068559158297Nonecode261Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: (Comn-SR V-1, Item No -13.5) 20mm nominal bore (Comn-SR V-1, 13.5.2)Nos323.42323.4210.0FalseNoneNoneFalseNoneFalse3234.20
4068560158297Nonecode262Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 25mm nominal bore (Comn-SR V-1, 13.4.1)Nos565.47565.478.0FalseNoneNoneFalseNoneFalse4523.760
4068561158297Nonecode263Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 32mm nominal bore (Comn-SR V-1, 13.4.2)Nos615.94615.948.0FalseNoneNoneFalseNoneFalse4927.520
4068562158297Nonecode264Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 40mm nominal bore (Comn-SR V-1, 13.4.3)Nos723.06723.0610.0FalseNoneNoneFalseNoneFalse7230.60
4068563158297Nonecode265Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 50mm nominal bore (Comn-SR V-1, 13.4.4)Nos880.65880.6510.0FalseNoneNoneFalseNoneFalse8806.50
4068564158297Nonecode266Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(Comn-SR V-1, Item No -13.34)Ltr9.279.2725000.0FalseNoneNoneFalseNoneFalse231750.00
4068565158297Nonecode267Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia (MR)Nos4334.04334.02.0FalseNoneNoneFalseNoneFalse8668.00
4068566158297Nonecode268Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC GratingNos830.0830.010.0FalseNoneNoneFalseNoneFalse8300.00
4068567158297Nonecode269Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5)Mtr226.6226.6361.0FalseNoneNoneFalseNoneFalse81802.60
4068568158297Nonecode270Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6)Each69.0169.0155.0FalseNoneNoneFalseNoneFalse3795.550
4068569158297Nonecode271Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6)Each197.76197.7655.0FalseNoneNoneFalseNoneFalse10876.80
4068570158297Nonecode272Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6)Each120.51120.5155.0FalseNoneNoneFalseNoneFalse6628.050
4068571158297Nonecode273Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7)Mtr423.33423.33430.0FalseNoneNoneFalseNoneFalse182031.90
4068572158297Nonecode274Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8)Each176.13176.1350.0FalseNoneNoneFalseNoneFalse8806.50
4068573158297Nonecode275Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9)110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8)Each311.06311.0640.0FalseNoneNoneFalseNoneFalse12442.40
4068574158297Nonecode276Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8)Each258.53258.5340.0FalseNoneNoneFalseNoneFalse10341.20
4068575158297Nonecode277Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 200 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.9Mtr1148.451148.45210.0FalseNoneNoneFalseNoneFalse241174.50
4068576158297Nonecode278Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 160mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.10)Each487.19487.1915.0FalseNoneNoneFalseNoneFalse7307.850
4068577158297Nonecode279Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 160mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.10)Each607.7607.715.0FalseNoneNoneFalseNoneFalse9115.50
4068578158297Nonecode280Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 160 mm dia PVC Tee (Comn-SR V-5, Item No -10.10.10)Each713.79713.7915.0FalseNoneNoneFalseNoneFalse10706.850
4068579158297Nonecode281Constructing brick masonry chamber of internal dimension 300x230mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Comn-SR V-5,Item No - 16.12)Each2856.192856.1910.0FalseNoneNoneFalseNoneFalse28561.90
4068580158297Nonecode282Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Comn-SR V-5,Item No - 16.9)Each5617.625617.6220.0FalseNoneNoneFalseNoneFalse112352.40
4068581158297Nonecode283Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.3 M depth & SFRC cover & frame. .(Comn-SR V-5,Item No -16.15.4)Each35729.6735729.672.0FalseNoneNoneFalseNoneFalse71459.340
4068582158297Nonecode284Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling,available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m m3 (Comn-SR V-1, Item No -1.6.1)Cum498.52498.52317.01FalseNoneNoneFalseNoneFalse158035.82520
4068583158297Nonecode285Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.(Comn-SR V-1,Item No -1.10)Cum164.8164.8317.01FalseNoneNoneFalseNoneFalse52243.2480
4068584158297Nonecode286Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore(Comn-SR V-2,Item No -13.6.3.2)Nos1261.751261.752.0FalseNoneNoneFalseNoneFalse2523.50
4068585158297Nonecode287Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(Comn-SR V-5,Item No -7.5.1) For DI/CI puddle flanges of 80mm dia.Each1627.41627.42.0FalseNoneNoneFalseNoneFalse3254.80
4068586158297Nonecode288Supplying, Intallation, testing and conmissioning of Solar Hot water Heater comprising of solar flat plat collector (FPC) of size 2120 x104 x100mm and stainless steel hot water storage tank with stainless steel Heat exchanges absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity with electrical back up arrangement excluding inlet and outlet pipes. SS model with 100mm thick of 48kg/Cum density rock wool insulation with 22WG Aluminium cladding. '300 Ltrs Capacity. (ELE SR 2-23-24)(7.3.3)Each73527.373527.35.0FalseNoneNoneFalseNoneFalse367636.50
4068587158297Nonecode289Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Item No 2.2.1 & Page No 4Point277.07277.07363.0FalseNoneNoneFalseNoneFalse100576.410
4068588158297Nonecode290Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box Item No 2.2.2 & Page No 4Point390.37390.37209.0FalseNoneNoneFalseNoneFalse81587.330
4068589158297Nonecode291Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Item No 2.2.3 & Page No 4Point571.65571.65286.0FalseNoneNoneFalseNoneFalse163491.90
4068590158297Nonecode292Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switches Item No 2.2.4 & Page No 4Point697.31697.3131.0FalseNoneNoneFalseNoneFalse21616.610
4068591158297Nonecode293Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box Item No 2.2.5 & Page No 4Point1018.671018.6710.0FalseNoneNoneFalseNoneFalse10186.70
4068592158297Nonecode294Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 1-2Way Item No 3.4.1 & Page No 7Each142.14142.1410.0FalseNoneNoneFalseNoneFalse1421.40
4068593158297Nonecode295Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way Item No 3.4.2 & Page No 7Each163.77163.7744.0FalseNoneNoneFalseNoneFalse7205.880
4068594158297Nonecode296Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Item No 3.4.3 & Page No 7Each182.31182.318.0FalseNoneNoneFalseNoneFalse1458.480
4068595158297Nonecode297Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Item No 3.4.4 & Page No 7Each226.6226.624.0FalseNoneNoneFalseNoneFalse5438.40
4068596158297Nonecode298Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Item No 3.4.5 & Page No 7Each268.83268.83353.0FalseNoneNoneFalseNoneFalse94896.990
4068597158297Nonecode299Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Item No 3.4.6 & Page No 7Each328.57328.5712.0FalseNoneNoneFalseNoneFalse3942.840
4068598158297Nonecode300Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16Way Item No 3.4.7 & Page No 7Each373.89373.8970.0FalseNoneNoneFalseNoneFalse26172.30
4068599158297Nonecode301Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18Way Item No 3.4.8 & Page No 7Each417.15417.158.0FalseNoneNoneFalseNoneFalse3337.20
4068600158297Nonecode302Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..1-2Module Item No 3.5.1 & Page No 7Each141.11141.1110.0FalseNoneNoneFalseNoneFalse1411.10
4068601158297Nonecode303Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2Module Item No 3.5.2 & Page No 7Each165.83165.8344.0FalseNoneNoneFalseNoneFalse7296.520
4068602158297Nonecode304Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module Item No 3.5.3 & Page No 7Each180.25180.258.0FalseNoneNoneFalseNoneFalse1442.00
4068603158297Nonecode305Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module Item No 3.5.4 & Page No 7Each241.02241.0224.0FalseNoneNoneFalseNoneFalse5784.480
4068604158297Nonecode306Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Module Item No 3.5.5 & Page No 7Each292.52292.52353.0FalseNoneNoneFalseNoneFalse103259.560
4068605158297Nonecode307Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module Item No 3.5.6 & Page No 7Each354.32354.3212.0FalseNoneNoneFalseNoneFalse4251.840
4068606158297Nonecode308Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16Module Item No 3.5.7 & Page No 7Each408.91408.9170.0FalseNoneNoneFalseNoneFalse28623.70
4068607158297Nonecode309Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18Module Item No 3.5.8 & Page No 7Each470.71470.718.0FalseNoneNoneFalseNoneFalse3765.680
4068608158297Nonecode310Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -6Amps one Way Item No 3.6.1 & Page No 8Each105.06105.061696.0FalseNoneNoneFalseNoneFalse178181.760
4068609158297Nonecode311Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch Item No 3.6.2 & Page No 8Each170.98170.9824.0FalseNoneNoneFalseNoneFalse4103.520
4068610158297Nonecode312Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket Item No 3.6.3 & Page No 8Each176.13176.13812.0FalseNoneNoneFalseNoneFalse143017.560
4068611158297Nonecode313Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Steeped fan Regulator Item No 3.6.4 & Page No 8Each367.71367.71130.0FalseNoneNoneFalseNoneFalse47802.30
4068612158297Nonecode314Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch Item No 3.6.7 & Page No 8Each185.4185.426.0FalseNoneNoneFalseNoneFalse4820.40
4068613158297Nonecode315Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Bell push Item No 3.6.8 & Page No 8Each182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
4068614158297Nonecode316Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch Item No 3.6.9 & Page No 8Each335.78335.7813.0FalseNoneNoneFalseNoneFalse4365.140
4068615158297Nonecode317Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket Item No 3.6.10 & Page No 8Each243.08243.0839.0FalseNoneNoneFalseNoneFalse9480.120
4068616158297Nonecode318Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone socket Item No 3.6.11 & Page No 8Each160.68160.687.0FalseNoneNoneFalseNoneFalse1124.760
4068617158297Nonecode319Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ 45/IO Outlet CAT - 6 Item No 3.6.12 & Page No 8Each347.11347.1115.0FalseNoneNoneFalseNoneFalse5206.650
4068618158297Nonecode320Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong bell Item No 12.2.1 & Page No 47Each253.38253.381.0FalseNoneNoneFalseNoneFalse253.380
4068619158297Nonecode321Supplying And Fixing Metal Fan Box with Round Hook. Item No 1.13 & Page No 3Each120.51120.51130.0FalseNoneNoneFalseNoneFalse15666.30
4068620158297Nonecode322Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary : 19mm dia 2mm thick Item No 1.2.1 & Page No 1Mtr67.9867.982100.0FalseNoneNoneFalseNoneFalse142758.00
4068621158297Nonecode323Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary : 25mm dia 2mm thick Item No 1.2.2 & Page No 1Mtr80.3480.345950.0FalseNoneNoneFalseNoneFalse478023.00
4068622158297Nonecode324Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary :325mm dia 2.5mm thick Item No 1.2.3 & Page No 1Mtr106.09106.09330.0FalseNoneNoneFalseNoneFalse35009.70
4068623158297Nonecode325Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19mm dia 2mm thick Item No 1.3.1 & Page No 1Mtr70.0470.04925.0FalseNoneNoneFalseNoneFalse64787.00
4068624158297Nonecode326Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25mm dia 2mm thick Item No 1.3.2 & Page No 1Mtr81.3781.372900.0FalseNoneNoneFalseNoneFalse235973.00
4068625158297Nonecode327Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick Item No 1.3.3 & Page No 1Mtr101.97101.97180.0FalseNoneNoneFalseNoneFalse18354.60
4068626158297Nonecode328CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm Item No 2.3.2 & Page No 4Mtr26.7826.788950.0FalseNoneNoneFalseNoneFalse239681.00
4068627158297Nonecode329CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm Item No 2.3.3 & Page No 4Mtr43.2643.269650.0FalseNoneNoneFalseNoneFalse417459.00
4068628158297Nonecode330CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm Item No 2.3.4 & Page No 4Mtr64.8964.891975.0FalseNoneNoneFalseNoneFalse128157.750
4068629158297Nonecode331CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6sqmm Item No 2.3.5 & Page No 4Mtr94.7694.76880.0FalseNoneNoneFalseNoneFalse83388.80
4068630158297Nonecode332CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10sqmm Item No 2.3.6 & Page No 4Mtr172.01172.011300.0FalseNoneNoneFalseNoneFalse223613.00
4068631158297Nonecode333CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16sqmm Item No 2.3.7 & Page No 5Mtr327.54327.54150.0FalseNoneNoneFalseNoneFalse49131.00
4068632158297Nonecode334Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Single Door : 16way SP &N Item No 5.19.5 & Page No 17Each3019.963019.965.0FalseNoneNoneFalseNoneFalse15099.80
4068633158297Nonecode335Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door : 6way TP &N Item No 5.19.12 & Page No 17Each5088.25088.21.0FalseNoneNoneFalseNoneFalse5088.20
4068634158297Nonecode336Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door : Double Door : 8way TP &N Item No 5.19.13 & Page No 17Each6273.736273.736.0FalseNoneNoneFalseNoneFalse37642.380
4068635158297Nonecode337Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. 5-32A SP MCB Item No 5.18.1 & Page No 16Each427.45427.45178.0FalseNoneNoneFalseNoneFalse76086.10
4068636158297Nonecode338Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32A DP MCB Item No 5.18.4 & Page No 16Each761.17761.176.0FalseNoneNoneFalseNoneFalse4567.020
4068637158297Nonecode339Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40A TPN MCB Item No 5.18.8 & Page No 16Each3135.323135.324.0FalseNoneNoneFalseNoneFalse12541.280
4068638158297Nonecode340Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2pole Item No 5.20.4 & Page No 17Each4736.974736.975.0FalseNoneNoneFalseNoneFalse23684.850
4068639158297Nonecode341Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 4 pole Item No 5.20.8 & Page No 17Each5301.415301.411.0FalseNoneNoneFalseNoneFalse5301.410
4068640158297Nonecode342Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole Item No 5.20.10 & Page No 17Each5711.355711.356.0FalseNoneNoneFalseNoneFalse34268.10
4068641158297Nonecode343LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10W Item No 11.3.1 & Page No 42Each567.53567.53317.0FalseNoneNoneFalseNoneFalse179907.010
4068642158297Nonecode344LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 20/22W Item No 11.3.2 & Page No 42Each710.7710.7110.0FalseNoneNoneFalseNoneFalse78177.00
4068643158297Nonecode345LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 36/40W Item No 11.3.3 & Page No 42Each1307.071307.075.0FalseNoneNoneFalseNoneFalse6535.350
4068644158297Nonecode346Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Item No 12.46 & Page No 51Each64.8964.8910.0FalseNoneNoneFalseNoneFalse648.90
4068645158297Nonecode347Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K Item No 11.11.5 & Page No 46Each277.07277.0710.0FalseNoneNoneFalseNoneFalse2770.70
4068646158297Nonecode348Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W Item No 11.5.3 & Page No 43Each1363.721363.72262.0FalseNoneNoneFalseNoneFalse357294.640
4068647158297Nonecode349Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. Item No 11.15 & Page No 46Each867.26867.267.0FalseNoneNoneFalseNoneFalse6070.820
4068648158297Nonecode350Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Item No 6.1 & Page No 29Each1536.761536.762.0FalseNoneNoneFalseNoneFalse3073.520
4068649158297Nonecode351Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm) Item No 6.2.2 & Page No 29Each4579.384579.3820.0FalseNoneNoneFalseNoneFalse91587.60
4068650158297Nonecode352Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Item No 6.3.1 & Page No 29Each3073.523073.52130.0FalseNoneNoneFalseNoneFalse399557.60
4068651158297Nonecode353Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70W Item No 11.8.3 & Page No 45Each6171.766171.769.0FalseNoneNoneFalseNoneFalse55545.840
4068652158297Nonecode354Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. : On wall/ceiling/Rafters/Girders Item No 13.7.1 & Page No 55Each125.66125.66711.0FalseNoneNoneFalseNoneFalse89344.260
4068653158297Nonecode355Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Item No 13.10 & Page No 56Each176.13176.13130.0FalseNoneNoneFalseNoneFalse22896.90
4068654158297Nonecode356Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame Item No 13.13 & Page No 56Each728.21728.2122.0FalseNoneNoneFalseNoneFalse16020.620
4068655158297Nonecode357Supplying and Fixing 50mm class A GI pipe up to 4.5 Mtrs. long with a reducing collar of 50x40mm to which, an extension of 250 mm pipe is fixed for 125 or 250/400 watts MV / sodium vapour street light fitting, using suitable clamps, bolts ,nuts, and wiring using suitable capacity wires. Item No 13.3 & Page No 55Each5615.565615.569.0FalseNoneNoneFalseNoneFalse50540.040
4068656158297Nonecode358Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Item No 13.5 & Page No 55Each166.86166.869.0FalseNoneNoneFalseNoneFalse1501.740
4068657158297Nonecode359Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 10L Item No 7.1.1 & Page No 33Each7790.927790.924.0FalseNoneNoneFalseNoneFalse31163.680
4068658158297Nonecode360Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. upto 30 Litres Item No 13.15.1 & Page No 56Each683.92683.924.0FalseNoneNoneFalseNoneFalse2735.680
4068659158297Nonecode361Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. Item No 8.3 & Page No 35Mtr45.3245.32150.0FalseNoneNoneFalseNoneFalse6798.00
4068660158297Nonecode362Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair Item No 8.2.2 & Page No 35Mtr21.6321.63150.0FalseNoneNoneFalseNoneFalse3244.50
4068661158297Nonecode363Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 20Pair Item No 8.2.7 & Page No 35Mtr154.5154.5100.0FalseNoneNoneFalseNoneFalse15450.00
4068662158297Nonecode364Supplying and drawing UTP-CAT 6E LAN cable. Item No 8.1 & Page No 35Mtr39.1439.14600.0FalseNoneNoneFalseNoneFalse23484.00
4068663158297Nonecode365Supplying & fixing of I/O socket with back box Single I/o Item No 8.10.1 & Page No 35Each504.7504.715.0FalseNoneNoneFalseNoneFalse7570.50
4068664158297Nonecode366Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Item No 8.12.5 & Page No 36Each8137.08137.01.0FalseNoneNoneFalseNoneFalse8137.00
4068665158297Nonecode367Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Item No 8.9.2 & Page No 35Each42693.542693.51.0FalseNoneNoneFalseNoneFalse42693.50
4068666158297Nonecode368Supplying & Fixing of switch mounting rack with power manager & Cable manager. 9U with 450mm depth Item No 8.4.3 & Page No 35Each8730.288730.281.0FalseNoneNoneFalseNoneFalse8730.280
4068667158297Nonecode369Supplying & Fixing of …Mtrs Cat 6 Patch Cable 1mtr Item No 8.11.1 & Page No 36Each230.72230.722.0FalseNoneNoneFalseNoneFalse461.440
4068668158297Nonecode370Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr Item No 8.11.2 & Page No 36Each264.71264.7112.0FalseNoneNoneFalseNoneFalse3176.520
4068669158297Nonecode371Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair Item No 8.13.2 & Page No 36Each394.49394.491.0FalseNoneNoneFalseNoneFalse394.490
4068670158297Nonecode372Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPS Item No 9.3.5 & Page No 37Each106677.1106677.11.0FalseNoneNoneFalseNoneFalse106677.10
4068671158297Nonecode373Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.75/80 AH capacity Item No 9.5.6 & Page No 38Each10477.1610477.1610.0FalseNoneNoneFalseNoneFalse104771.60
4068672158297Nonecode374Supplying, Installation, testing and commissioning of IP Dome Camera of 1/2.8*2Mega pixel Progressive CMOS, 1902x1080(2MP), 2.7mm to 13.5mm, F1.4, Motorized, with a min illumination of 0.05lux / F1.4 (colour,301RE) 0Lux/F1.4(IRon), 30M IR Distance, BLC/HLC/WDR(120db), min 2streams, compression should be H.265/H / MPEG, 128GB SD card, ONVIF Profiles, profile G&Q, POE camera, oprating temparature of 60 degrees. All the cameras should have CE,FCC,UL, IP66, IK10. The prices should include the necessary mounts and brackets. - MREach20806.020806.010.0FalseNoneNoneFalseNoneFalse208060.00
4068673158297Nonecode375Supplying, Installation, testing and commissioning of IP Bullet Camera of 1/2.8*2Mega pixel Progressive CMOS, 1902x1080(2MP), 2.7mm to13.5mm, F1.4, Motorized, with a min illumination of 0.05lux / F1.4 (colour,301RE) 0Lux/F1.4(IRon), 60M IR Distance, BLC/HLC/WDR(120db), min 2streams, compression should be H.265/H / MPEG, 128GB SD card, ONVIF Profiles, profile G&Q, POE camera, oprating temparature of 60 degrees. All the cameras should have CE,FCC,UL, IP66, IK10. The prices should include the necessary mounts and brackets. - MREach22351.022351.09.0FalseNoneNoneFalseNoneFalse201159.00
4068674158297Nonecode376Supplying, Installation, testing and commissioning of 4TB Survivelance Hard Disk The rate shall include all mounting accessories complete as required. - MREach14935.014935.01.0FalseNoneNoneFalseNoneFalse14935.00
4068675158297Nonecode377Supplying, Installation, testing and commissioning of Quad face plate Camera side with IOS. The rate shall include all mounting accessories complete as required. - MREach293.55293.5520.0FalseNoneNoneFalseNoneFalse5871.00
4068676158297Nonecode378Supplying, Installation, testing and commissioning of 43" LED Monitor. The rate shall include all mounting accessories complete as required. - MREach61800.061800.01.0FalseNoneNoneFalseNoneFalse61800.00
4068677158297Nonecode379Supplying and drawing UTP-CAT 6E LAN cable. Item No 8.1 & Page No 35Mtr39.1439.14925.0FalseNoneNoneFalseNoneFalse36204.50
4068678158297Nonecode380Supplying & fixing of I/O socket with back box Single I/o Item No 8.10.1 & Page No 35Each504.7504.720.0FalseNoneNoneFalseNoneFalse10094.00
4068679158297Nonecode381Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Item No 8.12.5 & Page No 36Each8137.08137.01.0FalseNoneNoneFalseNoneFalse8137.00
4068680158297Nonecode382Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Item No 8.9.2 & Page No 35Each42693.542693.51.0FalseNoneNoneFalseNoneFalse42693.50
4068681158297Nonecode383Supplying & Fixing of …Mtrs Cat 6 Patch Cable 1mtr Item No 8.11.1 & Page No 36Each230.72230.7210.0FalseNoneNoneFalseNoneFalse2307.20
4068682158297Nonecode384Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr Item No 8.11.2 & Page No 36Each264.71264.7120.0FalseNoneNoneFalseNoneFalse5294.20
4068683158297Nonecode385Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 250Amps 4Pole 36kA Item No 5.15.15 & Page No 16Each24251.3524251.351.0FalseNoneNoneFalseNoneFalse24251.350
4068684158297Nonecode386Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Item No 5.21 & Page No 17Each9532.659532.651.0FalseNoneNoneFalseNoneFalse9532.650
4068685158297Nonecode387Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Item No 5.33 & Page No 18Each9594.459594.451.0FalseNoneNoneFalseNoneFalse9594.450
4068686158297Nonecode388Supplying, fixing and wiring Electronic Trivector Meter (ETV)5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. Item No 5.35 & Page No 18Each5876.155876.151.0FalseNoneNoneFalseNoneFalse5876.150
4068687158297Nonecode389Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. Item No 5.34 & Page No 18Each578.86578.866.0FalseNoneNoneFalseNoneFalse3473.160
4068688158297Nonecode390Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. Item No 5.38 & Page No 18Each530.45530.453.0FalseNoneNoneFalseNoneFalse1591.350
4068689158297Nonecode391Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminium Strips Item No 5.40.2 & Page No 19Mtr3538.053538.058.0FalseNoneNoneFalseNoneFalse28304.40
4068690158297Nonecode392Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100Amps 4Pole 25kA Item No 5.15.9 & Page No 16Each8741.618741.6112.0FalseNoneNoneFalseNoneFalse104899.320
4068691158297Nonecode393Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. 63A TPN MCB Item No 5.18.9 & Page No 16Each3180.643180.643.0FalseNoneNoneFalseNoneFalse9541.920
4068692158297Nonecode394Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. 6-32A DP MCB Item No 5.18.4 & Page No 16Each761.17761.173.0FalseNoneNoneFalseNoneFalse2283.510
4068693158297Nonecode395Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm Item No 5.41.3 & Page No 19Mtr571.65571.6548.0FalseNoneNoneFalseNoneFalse27439.20
4068694158297Nonecode396Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG Item No 5.42.1 & Page No 19Sq CM0.520.52167800.0FalseNoneNoneFalseNoneFalse87256.00
4068695158297Nonecode397Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG Item No 5.42.2 & Page No 19Sq CM0.440.4444000.0FalseNoneNoneFalseNoneFalse19360.00
4068696158297Nonecode398Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. Item No 3.9 & Page No 8Sq CM0.360.36118800.0FalseNoneNoneFalseNoneFalse42768.00
4068697158297Nonecode399Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 10ft copper bonded rod with backfill compound Item No 12.60.3 & Page No 54Each8748.828748.824.0FalseNoneNoneFalseNoneFalse34995.280
4068698158297Nonecode400Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 6ft copper bonded rod with backfill compound Item No 12.60.2 & Page No 54Each6416.96416.92.0FalseNoneNoneFalseNoneFalse12833.80
4068699158297Nonecode401Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip Item No 12.58.2 & Page No 53Mtr84.4684.4640.0FalseNoneNoneFalseNoneFalse3378.40
4068700158297Nonecode402Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip Item No 12.58.7 & Page No 54Mtr587.1587.120.0FalseNoneNoneFalseNoneFalse11742.00
4068701158297Nonecode403Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 : 4Core 10Sqmm cable Item No 32.03, SL NO 199 ESCOM SR 23-24Mtr121.54121.5450.0FalseNoneNoneFalseNoneFalse6077.00
4068702158297Nonecode404Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 : 3.5Core 300Sqmm Item No 32.19, SL NO 215 ESCOM SR 23-24Mtr1097.991097.99225.0FalseNoneNoneFalseNoneFalse247047.750
4068703158297Nonecode405Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct : 2.5 sqmm to 25 sqmm Item No 21.05 SL NO 174 ESCOM SR 23-24Mtr21.5121.5150.0FalseNoneNoneFalseNoneFalse1075.50
4068704158297Nonecode406Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct : 300sqmm to 400Sqmm Item No 21.08 SL NO 177 ESCOM SR 23-24Mtr35.235.2225.0FalseNoneNoneFalseNoneFalse7920.00
4068705158297Nonecode407Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KVclass (metal only) 25mm dia Item No 63.01 SL NO 507 ESCOM SR 23-24Each81.3781.372.0FalseNoneNoneFalseNoneFalse162.740
4068706158297Nonecode408Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KVclass (metal only) 45mm dia Item No 63.04 SL NO 510 ESCOM SR 23-24Each202.91202.912.0FalseNoneNoneFalseNoneFalse405.820
4068707158297Nonecode409Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10Sqmm Long Barrel Item No 60.01 SL NO 469 ESCOM SR 23-24Each2.062.068.0FalseNoneNoneFalseNoneFalse16.480
4068708158297Nonecode410Heavy Duty Copper Terminal Long Barrel 150 Sqmm Copper Terminal, Apprx Wt: 98 Gm Item No 59.07 SL NO 463 ESCOM SR 23-24Each188.49188.492.0FalseNoneNoneFalseNoneFalse376.980
4068709158297Nonecode411Heavy Duty Copper Terminal Long Barrel 300 Sqmm Copper Terminal Item No 59.11 SL NO 467 ESCOM SR 23-24Each530.45530.456.0FalseNoneNoneFalseNoneFalse3182.70
4068710158297Nonecode412Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washers or welding as required. 300x50mm Item No 12.59.2 & Page No 54Mtr604.61604.615.0FalseNoneNoneFalseNoneFalse3023.050
4068711158297Nonecode413Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (UNI-SR V-1, Item No - 1.14.1 )Cum105.06105.06122.64FalseNoneNoneFalseNoneFalse12884.55840
4068712158297Nonecode414Providing and laying in position plain cement concrete for levelling course Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (UNI-SR V-1, Item No - 2.1.2 )Cum5833.925833.927.49FalseNoneNoneFalseNoneFalse43696.06080
4068713158297Nonecode415Providing and laying in position Reinforced cement concrete Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (UNI-SR V-1, Item No - 2.2.2.1 ) : Base Slab (including formwork cost at 8%)Cum7048.177048.1726.92FalseNoneNoneFalseNoneFalse189736.73640
4068714158297Nonecode416Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) : side wall inclusive of formwork at 10%Cum7341.847341.8412.24FalseNoneNoneFalseNoneFalse89864.12160
4068715158297Nonecode417Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) : Top covering slab inclusive of formwork at 50%Cum10011.610011.68.42FalseNoneNoneFalseNoneFalse84297.6720
4068716158297Nonecode418Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (UNI-SR V-1, Item No - 1.9 )Cum273.98273.9821.76FalseNoneNoneFalseNoneFalse5961.80480
4068717158297Nonecode419Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne92140.7192140.716.9FalseNoneNoneFalseNoneFalse635770.8990
4068718158297Nonecode420Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400% and having solid content of above 90% @ 1.6kg per Sqm in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g/ Sqm. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (UNI-SR V-3, Item No - 9.3 )Sqm914.64914.64106.2FalseNoneNoneFalseNoneFalse97134.7680
4068719158297Nonecode421Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm (Comn-SR V-5, Item No -11.2, Page No-111)Mtr4945.034945.031.5FalseNoneNoneFalseNoneFalse7417.5450
4068720158297Nonecode422Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (Comn-SR V-5, Item No -13, Page No-111)Each2204.22204.21.0FalseNoneNoneFalseNoneFalse2204.20
4068721158297Nonecode423Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 1.00 HP/0.75KW - 7 STG ( WS & UGD Comm SR V-5, Chapter-15, Item No - 6.1 )Nos20716.3920716.391.0FalseNoneNoneFalseNoneFalse20716.390
4068722158297Nonecode424Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.(P.No.140, I.No 12.4 , Vol 5 of PW,P & IWTD S.R 2022-23)Nos5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
4068723158297Nonecode425Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 0.00 to 50.00 mtrs 1.1 O010AMtr381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
4068724158297Nonecode426Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 50.00 to 100.00 mtrs 1.2 O010BMtr477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
4068725158297Nonecode427Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 100.00 to 150.00 mtrs 1.3 O010CMtr507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
4068726158297Nonecode428Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 150.00 to 200.00 mtrs 1.4 O010DMtr589.16589.1650.0FalseNoneNoneFalseNoneFalse29458.00
4068727158297Nonecode429Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 200.00 to 250.00 mtrs 1.5 O010EMtr691.13691.1350.0FalseNoneNoneFalseNoneFalse34556.50
4068728158297Nonecode430Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 250.00 to 300.00 mtrs 1.6 O010FMtr762.2762.250.0FalseNoneNoneFalseNoneFalse38110.00
4068729158297Nonecode431Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 300.00 to 350.00 mtrs 1.7 O010FMtr894.04894.0450.0FalseNoneNoneFalseNoneFalse44702.00
4068730158297Nonecode432Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 350.00 to 400.00 mtrs 1.6 O010FMtr965.11965.1150.0FalseNoneNoneFalseNoneFalse48255.50
4068731158297Nonecode433Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 400.00 to 450.00 mtrs 1.6 O010FMtr1219.521219.5250.0FalseNoneNoneFalseNoneFalse60976.00
4068732158297Nonecode434Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socketconforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (P.No.143, I.No 12.32. Vol 5 of PW,P & IWTD S.R 2022-23)Mtr1990.991990.9930.0FalseNoneNoneFalseNoneFalse59729.70
4068733158297Nonecode435Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)Nos168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
4068734158297Nonecode436Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)Nos154.5154.55.0FalseNoneNoneFalseNoneFalse772.50
4068735158297Nonecode437Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For -For -7.5 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00”. (Page No. : 152, Item No.13.15.7 KWS & DB S R Vol-5 2022-23)Each42034.342034.31.0FalseNoneNoneFalseNoneFalse42034.30
4068736158297Nonecode438Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1X3X6 Sqm. (Page No. : 154, Item No.13.22.4, KWS & DB S R Vol-5 2022-23)Mtr190.55190.55450.0FalseNoneNoneFalseNoneFalse85747.50
4068737158297Nonecode439Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Page No. : 156, Item No.13.32 KWS & DB S R Vol-5 2022-23)Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
4068738158297Nonecode440Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. 50 mm dia (PWD SR 2022-23 , vol-2, P119, I no 13.10.6)Mtr709.67709.672.0FalseNoneNoneFalseNoneFalse1419.340
4068739158297Nonecode441Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps. (Page No. : 155, Item No.13.23.2 , KWS & DB S R Vol-5 2022-23)Each16377.016377.02.0FalseNoneNoneFalseNoneFalse32754.00
4068740158297Nonecode442Erection of single phase preventer / ammeters / including fixing selector switch / voltmeter / current operated earth leakage circuit breakers / voltage operated circuit breaker / above 100A fuse channel set (3 Nos) HRC fuses above 100A (3 Nos.) / Digital ammeter/digital volt meter/set of 3 indicating lamps /MCB / Relays /A-V selector switches including wiring using suitable capacity wires, bolts, nuts,screws. (PWD Ele SR 2022-23 Pg no.46 Sl no.13.16)Nos203.94203.941.0FalseNoneNoneFalseNoneFalse203.940
4068741158297Nonecode443Fabricating, supplying and mounting MS box made out of 18 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation provided with hinged front cover with with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 Tanks Treatment wit powder coat ed paint & finaly finished with approved colour & etc. (PWD Ele SR 2-23-24 Pg no.20, Sl no.5.42.3)Sqm0.390.3930000.0FalseNoneNoneFalseNoneFalse11700.00
4068742158297Nonecode444Supplying and fixing miniature circuit breakers/isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as required - 40 to 63 amps triple pole. ( PWD Ele SR 2-23-24 P-47, It No.6.16.2)Each3180.643180.641.0FalseNoneNoneFalseNoneFalse3180.640
4068743158297Nonecode445Supplying and running of GI copper strip or grounding connection using necessary fixing material required 600x600x3mm GI plate. (PWD Ele SR 2-23-24 (P-54, Sl no.12.58.6)Each901.25901.251.0FalseNoneNoneFalseNoneFalse901.250
4068744158297Nonecode446Supplying and fixing Porcelain fuse channel with cut out on the existing wooden /panel using necessary nuts bolts and washer etc., complete. 16 A. (P-No.10 , I.No.5.7.1 KPWD Ele SR 2022-23),Each161.71161.713.0FalseNoneNoneFalseNoneFalse485.130
4068745158297Nonecode447Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. (P.No.115, I.No.13.4.4 of KPWD Elec S.R 2022-23)Nos880.65880.651.0FalseNoneNoneFalseNoneFalse880.650
4068746158297Nonecode4481.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 , 4 core 16sqmm. ( Ele SR 22-23 Pg no. sl no. 32.05)Mtr146.1146.130.0FalseNoneNoneFalseNoneFalse4383.00
4068747158297Nonecode449Labour charges for Laying of 1.1 KV Class UG cable 6 Sqmm to 16 sqmmMtr12.2412.2430.0FalseNoneNoneFalseNoneFalse367.20
4068748158297Nonecode450Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating in Hard soil etc., complete. complete as per specifications and direction of the Engineer-in-Charge. (As per Civil SR KSRB I-1.17.1, P-10, vol -1)Mtr199.82199.8230.0FalseNoneNoneFalseNoneFalse5994.60
4068749158297Nonecode451Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 65mm dia. Vol-5 SR(2021-22), P-142, I- 11.2.7Mtr740.57740.5730.0FalseNoneNoneFalseNoneFalse22217.10
4068750158297Nonecode452Supplying and fixing LT cast iron pot heads suitable for 1.1 KV class UG cable filled wiith necessary bitumen / insulating compound complete. With terminals, clamps, bolts nuts and washers etc.complete for 16 Sqmm as per specification. (KPWD Ele SR Pg no.62 sl no.7.13.2)Each578.86578.861.0FalseNoneNoneFalseNoneFalse578.860
4068751158297Nonecode453Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m. (P.No.6, I.No.1.6.1 of KPWD S.R 2022-23)Cum498.52498.5274.25FalseNoneNoneFalseNoneFalse37015.110
4068752158297Nonecode454Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/Sqm: 63mm(weight of pipe -0.662 kg) (P.No.134, I.No.M010C of KPWD S.R 2022-23)Mtr143.17143.17165.0FalseNoneNoneFalseNoneFalse23623.050
4068753158297Nonecode455Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (P.No.7, I.No.1.10 of KPWD S.R 2022-23)Cum164.8164.855.69FalseNoneNoneFalseNoneFalse9177.7120
4068754158297Nonecode456Design, supplying, erecting testing and commissioning of -passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,. (item No - 14.4.2 PWD Ele SR 2023-2024) D.With Out Machine Room-SS Finish ( 8-Passgenrs 5 - Stops )Each1640458.221640458.221.0FalseNoneNoneFalseNoneFalse1640458.220
4068755158297Nonecode457Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards. 2. After commissioning of plant necessary testing to be done for the Satisfaction of the Engineer in charge. 3. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. (UNI-SR V-5, Item No - 22.2.2 Page No - 251 ) (50KLD)Each2621350.02621350.01.0FalseNoneNoneFalseNoneFalse2621350.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17271827890000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17271827890000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17271827890000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17271827890000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17271827890000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17271828090000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17271828120000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17271828180000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17271828210000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17271828250000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17271828280000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17271828330000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17271828370000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17271828410000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17271828490000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17271828520000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17271828560000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17271828590000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17271828640000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17271828690000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1727185972000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone