createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727177960192
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd3449000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-10-2024 15:00:00
tenderQueryClose25-09-2024 10:14:00
technicalBidOpen05-10-2024 16:00:00
publishedDate24-09-2024 17:52:21
publishedByPostKPTCL_SE2_TP_BNG
publishedByUserKPE11138 - KRISHNAREDDY G T
bidValidityPeriod180
noOfCalls1
preBidMeetingDate25-09-2024 10:05:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonKRISHNAREDDY G.T
splitEmdRequiredYnTrue
emdBankGuarantee2449000.00
emdCash1000000.00
bgValidityPeriod225
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022274744
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1727177960193
version11
createdDateNone
modifiedDateNone
tenderNumberKPTCL/2024-25/TL/WORK_INDENT872
titleConst. of 220kV DC line to LILO 2nd circuit of 220kV Mahalingapur- Kudachi DC line at 220kV Athani Ss for a distance of 25.567km along with shifting of 110kV Athani Haliyal DC line for a distance of 2.319km along with decommissioning of 220kV and 110kV line matrls and equips and Construction of 2 Nos. of 220kV TBs at 220kV Athani Ss in Athani Taluk Belagavi District on TTK basis under GEC scheme
descriptionConstruction of 220kV DC Transmission line to LILO 2nd circuit of 220kV Mahalingapur- Kudachi DC Transmission line at 220kV Athani Sub-station for a distance of 25.567km along with shifting of 110kV Athani- Haliyal DC Transmission line from Tower No. 11 to 3 for a distance of 2.319km and decommissioning of 220kV & 110kV line Materials/ Equipments and Construction of 2 Nos. of 220kV Terminal Bays at 220kV Athani Sub-station in Athani Taluk, Belagavi District on Total Turnkey Basis under Green Energy Corridor -Phase II including Supply of all Materials/Equipments and Erection (including Civil Works) of all Materials/Equipments, Testing and Commissioning
categoryWORKS
categoryTextWorks
ecv344903678.56
deptNameKarnataka Power Transmission Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location4550
locationNameKPTCL CEE Corporate Office Tendering and Procurement Bengaluru
provisionalAmount344904587.82
groupOverheadTotalNone
fileNumberCEE/TnP/220kV/MAHALINGAPURKUDACHI/TTK/TLTB1559
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17271779600000NoneNoneTransmission LineTB Supply33388910.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067579158221NoneSS1CIRCUIT BREAKER : SF-6 circuit breakers with rigid, bi-metallic terminal connector suitable for Drake ACSR with spring/semi pneumatic/ pneumatic type operating mechanism with mounting structure complete as per technical specifications. 220 kV, 1250 A, 40 kA SF6 CBNo1980358.591980358.592.0FalseNoneNoneFalseNoneFalse3960717.180
4067580158221NoneSS2ISOLATORS : Isolators including marshalling box,Rigid type terminal connectors with solid core cylindrical post insulators as per technical specifications. 220 kV, 1250 A, 40kA class double break Electrically cum manually operated isolator with solid core insulators 1) Upright mounting type with manually operated Earth Switch LPH 5750 mmSet668210.39668210.392.0FalseNoneNoneFalseNoneFalse1336420.780
4067581158221NoneSS32) Upright mounting type without Earth switch LPH 8250 mm.Set566836.6566836.64.0FalseNoneNoneFalseNoneFalse2267346.40
4067582158221NoneSS43)Upright mounting type without Earth switch LPH 5750 mm.Set559697.6559697.62.0FalseNoneNoneFalseNoneFalse1119395.20
4067583158221NoneSS54)Underhung mounting type without earth switch Note:Terminal connectors for Isolators : Rigid type suitable for Drake ACSR- 48 Nos Flexible type suitable for 63mm Al.pipe -12NosSet585398.0585398.02.0FalseNoneNoneFalseNoneFalse1170796.00
4067584158221NoneSS6CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR with with marshalling KIOSK complete as per technical specifications. 1)220 kV class, 31.5 KA, CT of ratio 800-600-400-300/1-1-1A with additional 2 cores of 800/1A Type-1(1no. of main CTs are used as NCTs) For metering : Accuracy 0.2s, Burden 10 VA For differential /Distance protection PS class , Knee Point Voltage = 1600 V at 800/1 A RCt 5 ohms & 600V at 300/1A Rct 1.5 ohms For Bus bar protection : PS class, Knee Point Voltage = 1600 V at 800/1 A RCt 5 ohms Note: All the CTs in each kV class shall be of one and the same make for inter-changeability & reliability of performance.No419773.19419773.196.0FalseNoneNoneFalseNoneFalse2518639.140
4067585158221NoneSS7CAPACITIVE VOLTAGE TRANSFORMER :Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications. 245kV class,CVTs 4400 PF, 220kV/root 3/110V/root 3-110V/root 3. Protection Core - 1 & 2 :150 VA, class 3PNo191325.19191325.196.0FalseNoneNoneFalseNoneFalse1147951.140
4067586158221NoneSS8SURGE ARRESTOR : (Procelain housing) metal oxide gapless type with rigid bimetallic terminal connectors as per technical specifications.. 198 kV, 10 KA, class -III, Heavy duty Metal oxide. Note: Surge arrestors are provided with surge monitors & insulating baseNo69962.269962.26.0FalseNoneNoneFalseNoneFalse419773.20
4067587158221NoneSS9Control and Relay panel Complete SAS Compatible : 220 kV Line panel Type 2L( as per Annexure RPP1-SAS) Note:- Note : 1)The Accuracy class of metering core of CTs and also trivector meter of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents. 2)The proposed C&R Panel shall be interfaced with M/s.Sifang make SAS. 3) The proposed C&R Panel shall be interfaced with existing Bus-bar protection Scheme and Sifang make SAS and also to provide gate way for SLDC integration. 4) SLDC end, KPTCL SCADA will take care. 5) The Electronic Trivector meter with ABT-DLMS features shall be provided for both line TBsNo1867562.41867562.42.0FalseNoneNoneFalseNoneFalse3735124.80
4067588158221NoneSS10Total Weight of Station structures & Mounting Structures (excluding Bolts & nuts)MT159913.6159913.629.08FalseNoneNoneFalseNoneFalse4650287.4880
4067589158221NoneSS11Total Weight of Bolts & nuts of Station structures & Mounting StructuresMT168480.4168480.41.4279FalseNoneNoneFalseNoneFalse240573.163160
4067590158221NoneSS13Rigid bus with taps & clamps: (i) Aluminium Tube conforming to 6340 WP of IS-5082 / 1969 (BS 1600-Sch.40) of 75 mm size - 220 kV sideMtr1871.481871.48180.0FalseNoneNoneFalseNoneFalse336866.40
4067591158221NoneSS14ii. Aluminium Tube conforming to 6340 WP of IS-5082 / 1969 (BS 1600-Sch.40) of 63 mm size for connecting isolator to vertical tap - 220 kV side & 110kV sideMtr1713.361713.36126.0FalseNoneNoneFalseNoneFalse215883.360
4067592158221NoneSS15iii. Inverted V taps made of 63 mm Aluminium Tube (BS - 1600) of 2500mm vertical height for vertical portion and cross bus on 220 kV Side with rounded off End.No5370.185370.1812.0FalseNoneNoneFalseNoneFalse64442.160
4067593158221NoneSS16iv. Post insulator clamps suitable for 75 mm Aluminium pipe and post insulator Solid core type 220 kV side a) Rigid typeNo2204.242204.2412.0FalseNoneNoneFalseNoneFalse26450.880
4067594158221NoneSS17b) Expansion typeNo6279.966279.9612.0FalseNoneNoneFalseNoneFalse75359.520
4067595158221NoneSS18c)Corona Bell suitable for Aluminium pipe 75mm on 220kVsideNo801.22801.226.0FalseNoneNoneFalseNoneFalse4807.320
4067596158221NoneSS19INSULATORS: Post Insulators-Cylindrical Solid Core Insulators as per IS : 5350, Part-II & III & as per technical specification: 1. For 220kV side -2 units/stack Post Insulators of Rigid BusStack32336.7232336.7224.0FalseNoneNoneFalseNoneFalse776081.280
4067597158221NoneSS202.11kV,120 KN Disc Insulators: (Refer TechnoCommercial Sheet for details)No946.36946.36192.0FalseNoneNoneFalseNoneFalse181701.120
4067598158221NoneSS213.11kV,90 KN Disc Insulators : (Refer TechnoCommercial Sheet for details)No699.74699.7484.0FalseNoneNoneFalseNoneFalse58778.160
4067599158221NoneSS22INSULATOR HARDWARE & CLAMPS as per technical specification: 1. Bolted type Single Tension clamp with hardware suitable for DRAKE ACSR 120KN,20mm -220 kV sideNo2957.082957.0812.0FalseNoneNoneFalseNoneFalse35484.960
4067600158221NoneSS232. Bolted type Single Suspension clamp with hardware suitable for Drake ACSR 90KN,16mm -220 kV sideNo1797.141797.146.0FalseNoneNoneFalseNoneFalse10782.840
4067601158221NoneSS243.C type Wedge connectors: C type Wedge connectors(T-Type) suitable for Drake to Drake ACSR - 220 kV sideNo2719.92719.942.0FalseNoneNoneFalseNoneFalse114235.80
4067602158221NoneSS25AC Distribution box (out door ): AC distribution Box double front (out door) 24 terminal 1200 x 1350 x 600 mm , 2 I/C of 100 Amps MCCB 20 KA + 24 O/G MCB 16 Amps + 2 O / G of 100 A HRC fuseNo144207.8144207.81.0FalseNoneNoneFalseNoneFalse144207.80
4067603158221NoneSS26LT Power Cable: 1.1 kV class PVC insulated Alluminium power cable(AC supply for lighting etc,.) 4 x 70 Sq mm with glands/lugs/ferrulesMtr639.56639.56200.0FalseNoneNoneFalseNoneFalse127912.00
4067604158221NoneSS27PVC insulated Copper Control Cable with Lugs / Ferrules. 1.1 KV class,Size of cable: i) 19 Core 2.5 Sq.mm. Copper Control CablesKm619500.0619500.02.0FalseNoneNoneFalseNoneFalse1239000.00
4067605158221NoneSS28ii) 10 Core 2.5 Sq.mm. Copper Control CablesKm369340.0369340.01.5FalseNoneNoneFalseNoneFalse554010.00
4067606158221NoneSS29iii) 4 Core 6.0 Sq.mm. Copper Control CablesKm291460.0291460.03.5FalseNoneNoneFalseNoneFalse1020110.00
4067607158221NoneSS30iv) 4 Core 2.5 Sq.mm. Copper Control CablesKm167560.0167560.00.7FalseNoneNoneFalseNoneFalse117292.00
4067608158221NoneSS31v) 4 Core 4 Sq.mm. Copper Control CablesKm208860.0208860.00.8FalseNoneNoneFalseNoneFalse167088.00
4067609158221NoneSS32vi) Copper PVC instrumentation cable armoured (screened cable) 1P X 1.5 Sq mmKm33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
4067610158221NoneSS33PLCC equipments: 1. Wave Trap (suspension type) 0.5mH, 1250A, 31.5 kA, 50-150Hz and 100-500kHzNo349811.0349811.04.0FalseNoneNoneFalseNoneFalse1399244.00
4067611158221NoneSS342. 40 W Carrier cabinet Single channel-40WSet858107.8858107.82.0FalseNoneNoneFalseNoneFalse1716215.60
4067612158221NoneSS353. Coupling device MCD 80 LMU+LMDUSet241298.2241298.22.0FalseNoneNoneFalseNoneFalse482596.40
4067613158221NoneSS364. Protection coupler-4 command versionSet416917.6416917.62.0FalseNoneNoneFalseNoneFalse833835.20
4067614158221NoneSS375. Co axial cable 75 OhmKm344560.0344560.01.0FalseNoneNoneFalseNoneFalse344560.00
4067615158221NoneSS38Station and Yard Lighting (Outdoor and Indoor) Lighting/ Lightning Masts. (Refer TechnoCommercial Sheet for details)LS236000.0236000.01.0FalseNoneNoneFalseNoneFalse236000.00
4067616158221NoneSS39Earth Mat formation : iv) Supplying of Grounding of equipments by providing Cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm as per specification and supplying and fixing of RCC collar of size 450mm dia, 450mm height and 50mm thick.Set16863.3816863.3830.0FalseNoneNoneFalseNoneFalse505901.40
17271779600000NoneNoneTransmission LineLine Supply236693372.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067617158222NoneLS1Total weight of the Towers (High Tensile Steel) excluding Bolt & NutsMT183602.1183602.1273.9935FalseNoneNoneFalseNoneFalse50305781.986350
4067618158222NoneLS2Total weight of the Towers (Mild Steel) excluding Bolt & NutsMT167182.4167182.4415.1737FalseNoneNoneFalseNoneFalse69409735.582880
4067619158222NoneLS3Total weight of the Bolts and NutsMT176138.6176138.633.1709FalseNoneNoneFalseNoneFalse5842675.886740
4067620158222NoneLS4Tower Accessories: a) Supplying and fixing GI angle iron 450X450x50 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5mts length each at inner and outer surface of tower to facilitate running of barbed wireSet5084.625084.62109.0FalseNoneNoneFalseNoneFalse554223.580
4067621158222NoneLS5b) Supplying and fixing of Barbed wire as per the specification.Rmtr94.494.425100.0FalseNoneNoneFalseNoneFalse2369440.00
4067622158222NoneLS6c) Number Plates (1 No. per tower)No392.94392.94109.0FalseNoneNoneFalseNoneFalse42830.460
4067623158222NoneLS7d) Danger Board (1 No. per tower)No392.94392.94109.0FalseNoneNoneFalseNoneFalse42830.460
4067624158222NoneLS8e) Circuit Plates (1 No. per circuit)No392.94392.94218.0FalseNoneNoneFalseNoneFalse85660.920
4067625158222NoneLS9f) Phase Plates (Set of 3 Nos.)Set325.68325.68218.0FalseNoneNoneFalseNoneFalse70998.240
4067626158222NoneLS10g) Earth Bonds300mm longNo579.38579.3859.0FalseNoneNoneFalseNoneFalse34183.420
4067627158222NoneLS11h) Earth Bonds 450mm longNo664.34664.3450.0FalseNoneNoneFalseNoneFalse33217.00
4067628158222NoneLS12i) Supplying of Grounding of tower including cost of 40mm dia, 2.5mm thick, class 'C' GI pipe of 3mtrs length as per specifications with 50x6 GI flats 3 mtrs long, salt, charcoal.Set6443.986443.98109.0FalseNoneNoneFalseNoneFalse702393.820
4067629158222NoneLS13Conductors: i. Drake ACSR (Also added Sl. no. SS12 of Station Supply portion)Km456660.0456660.0156.303FalseNoneNoneFalseNoneFalse71377327.980
4067630158222NoneLS14ii. Lynx ACSRKm226560.0226560.014.123FalseNoneNoneFalseNoneFalse3199706.880
4067631158222NoneLS15iii.7/3.15 GI wire for ground conductorKm103840.0103840.02.354FalseNoneNoneFalseNoneFalse244439.360
4067632158222NoneLS16Insulators strings suitable for DRAKE ACSR CONDUCTOR i. Single Tension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X16nos. of 120kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X16nos.of 120kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X16nos. of 120kN Disc insulatorsStrings15141.7615141.76714.0FalseNoneNoneFalseNoneFalse10811216.640
4067633158222NoneLS17ii. Single Suspension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X14nos. of 90kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X14nos. of 90kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X14nos. of 90kN Disc insulatorsStrings9796.369796.36480.0FalseNoneNoneFalseNoneFalse4702252.80
4067634158222NoneLS18Insulators strings suitable for LYNX ACSR CONDUCTOR : i. Single Tension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X8nos. of 90kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X8nos. of 90kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X8nos. of 90kN Disc insulatorsStrings5597.925597.92108.0FalseNoneNoneFalseNoneFalse604575.360
4067635158222NoneLS19ii .Single Suspension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X7nos. of 90kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X7nos. of 90kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X7nos. of 90kN Disc insulatorsStrings4898.184898.186.0FalseNoneNoneFalseNoneFalse29389.080
4067636158222NoneLS20Insulator Hardwares for DRAKE ACSR CONDUCTOR: i. Compression type Single Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 1X16 units of 120kN Disc insulators to suit DRAKE ACSR conductorNo4434.444434.44342.0FalseNoneNoneFalseNoneFalse1516578.480
4067637158222NoneLS21ii. Compression type Double Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 2X16 units of 120kN Disc insulators to suit DRAKE ACSR conductorNo7898.927898.92186.0FalseNoneNoneFalseNoneFalse1469199.120
4067638158222NoneLS22iii. Compression type Single Suspension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for: a. 1X14 units of 90kN Disc insulators to suit DRAKE ACSR conductorNo2769.462769.46228.0FalseNoneNoneFalseNoneFalse631436.880
4067639158222NoneLS23iv. Compression type Double Suspension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 2X14 units of 90kN Disc insulators to suit DRAKE ACSR conductorNo5258.085258.08126.0FalseNoneNoneFalseNoneFalse662518.080
4067640158222NoneLS24Insulator Hardwares for LYNX ACSR CONDUCTOR: i. Compression type Single Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 1X8 units of 90kN Disc insulators to suit LYNX ACSR conductorNo1936.381936.3860.0FalseNoneNoneFalseNoneFalse116182.80
4067641158222NoneLS25ii. Compression type Double Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 2X8 units of 90kN Disc insulators to suit LYNX ACSR conductorNo5511.785511.7824.0FalseNoneNoneFalseNoneFalse132282.720
4067642158222NoneLS26iii. Compression type Single Suspension (excluding Disc Insulators) with hardwares & arcing horns suitable for 1X7units of 90kN Disc insulators to suit LYNX ACSR conductorNo2351.742351.746.0FalseNoneNoneFalseNoneFalse14110.440
4067643158222NoneLS27Accessories for Conductors: A.Drake ACSR: a) Mid Span Compression JointsNo1357.01357.050.0FalseNoneNoneFalseNoneFalse67850.00
4067644158222NoneLS28b) Pre formed armour rods suitable for 220kV lineNo3945.923945.92351.0FalseNoneNoneFalseNoneFalse1385017.920
4067645158222NoneLS29c) Repair sleevesNo1044.31044.330.0FalseNoneNoneFalseNoneFalse31329.00
4067646158222NoneLS30d) P G ClampsNo953.44953.44528.0FalseNoneNoneFalseNoneFalse503416.320
4067647158222NoneLS31e) Vibration dampersNo1820.741820.741224.0FalseNoneNoneFalseNoneFalse2228585.760
4067648158222NoneLS32B. Lynx ACSR: a) Mid Span Compression JointsNo788.24788.245.0FalseNoneNoneFalseNoneFalse3941.20
4067649158222NoneLS33b) Pre formed armour rodsNo1490.341490.346.0FalseNoneNoneFalseNoneFalse8942.040
4067650158222NoneLS34c) Repair sleevesNo698.56698.565.0FalseNoneNoneFalseNoneFalse3492.80
4067651158222NoneLS35d) P G ClampsNo915.68915.6884.0FalseNoneNoneFalseNoneFalse76917.120
4067652158222NoneLS36e) Vibration dampersNo1196.521196.5296.0FalseNoneNoneFalseNoneFalse114865.920
4067653158222NoneLS37Hardwares & Accessories for Earthwire: a) Mid Span Compression JointsNo539.26539.263.0FalseNoneNoneFalseNoneFalse1617.780
4067654158222NoneLS38b) Repair sleevesNo364.62364.623.0FalseNoneNoneFalseNoneFalse1093.860
4067655158222NoneLS39c) P G ClampsNo475.54475.5414.0FalseNoneNoneFalseNoneFalse6657.560
4067656158222NoneLS40d) Single Tension clamps (bolted type)No1456.121456.1214.0FalseNoneNoneFalseNoneFalse20385.680
4067657158222NoneLS41e) Single Suspension clamps (bolted type)No1535.181535.181.0FalseNoneNoneFalseNoneFalse1535.180
4067658158222NoneLS42OPGW Cable and its Tower accessories required for replacement of existing ground wire by OPGW & Joint box Assembly for 220kV lines . A.OPGW Cable & its accessories : a) 48Fibre (DWSM) OPGW fibre optic cable for 220kV line (inclusive of conductor offline stringing)Km227740.0227740.028.0FalseNoneNoneFalseNoneFalse6376720.00
4067659158222NoneLS43b) Suspension clamp assembly for 48 fibre OPGWNo2499.242499.2458.0FalseNoneNoneFalseNoneFalse144955.920
4067660158222NoneLS44c) Tension fitting Assembly for 48fibre OPGW including all accessories for joint box(splicing location)No5534.25534.27.0FalseNoneNoneFalseNoneFalse38739.40
4067661158222NoneLS45d) Tension Assembly for dead end for 48fibre OPGWSet2767.12767.12.0FalseNoneNoneFalseNoneFalse5534.20
4067662158222NoneLS46e) Tension Assembly -Double Tension pass through for 48fibre OPGWNo5097.65097.636.0FalseNoneNoneFalseNoneFalse183513.60
4067663158222NoneLS47f) Vibration dampers for 48fibre OPGWNo578.2578.2202.0FalseNoneNoneFalseNoneFalse116796.40
4067664158222NoneLS48g) Down lead clamp assembly for 48fibre OPGWNo265.5265.521.0FalseNoneNoneFalseNoneFalse5575.50
4067665158222NoneLS49h) Joint box for 48fibre OPGWNo9349.149349.149.0FalseNoneNoneFalseNoneFalse84142.260
4067666158222NoneLS50B. FODP: FODP 48 F: Indoor type consisting of 2nos of rack mounted LIU (to be housed in FODP) with 24 ports each with FCPC coupling & pigtailsNo78099.4878099.482.0FalseNoneNoneFalseNoneFalse156198.960
4067667158222NoneLS51C. Fibre Optic approach Cable: 48 fibre(DWSM)-including installation hardware set for 48 fibre approach cableKm240720.0240720.00.5FalseNoneNoneFalseNoneFalse120360.00
17271779600000NoneNoneTransmission LineTB Erection3756530.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067668158223NoneSE1CIRCUIT BREAKER : SF-6 circuit breakers with rigid, bi-metallic terminal connector suitable for Drake ACSR with spring/semi pneumatic/pneumatic type operating mechanism with mounting structure complete as per technical specifications. 220 kV, 1250 A, 40 kA SF6 CBNo84774.7484774.742.0FalseNoneNoneFalseNoneFalse169549.480
4067669158223NoneSE2ISOLATORS : Isolators including marshalling box,Rigid type terminal connectors with solid core cylindrical post insulators as per technical specifications. 220 kV, 1250 A, 40kA class double break Electrically cum manually operated isolator with solid core insulators 1) Upright mounting type with manually operated Earth Switch LPH 5750 mmSet10152.7210152.722.0FalseNoneNoneFalseNoneFalse20305.440
4067670158223NoneSE32) Upright mounting type without Earth switch LPH 8250 mm.Set10152.7210152.724.0FalseNoneNoneFalseNoneFalse40610.880
4067671158223NoneSE43)Upright mounting type without Earth switch LPH 5750 mm.Set10152.7210152.722.0FalseNoneNoneFalseNoneFalse20305.440
4067672158223NoneSE54)Underhung mounting type without earth switch Note:Terminal connectors for Isolators : Rigid type suitable for Drake ACSR- 48 Nos Flexible type suitable for 63mm Al.pipe -12NosSet14466.814466.82.0FalseNoneNoneFalseNoneFalse28933.60
4067673158223NoneSE6CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR with with marshalling KIOSK complete as per technical specifications. 1)220 kV class, 31.5 KA, CT of ratio 800-600-400-300/1-1-1A with additional 2 cores of 800/1A Type-1(1no. of main CTs are used as NCTs) For metering : Accuracy 0.2s, Burden 10 VA For differential /Distance protection PS class , Knee Point Voltage = 1600 V at 800/1 A RCt 5 ohms & 600V at 300/1A Rct 1.5 ohms For Bus bar protection : PS class, Knee Point Voltage = 1600 V at 800/1 A RCt 5 ohms Note: All the CTs in each kV class shall be of one and the same make for inter-changeability & reliability of performance.No15134.2915134.296.0FalseNoneNoneFalseNoneFalse90805.740
4067674158223NoneSE7CAPACITIVE VOLTAGE TRANSFORMER :Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications. 245kV class,CVTs 4400 PF, 220kV/root 3/110V/root 3-110V/root 3. Protection Core - 1 & 2 :150 VA, class 3PNo9397.919397.916.0FalseNoneNoneFalseNoneFalse56387.460
4067675158223NoneSE8SURGE ARRESTOR : (Procelain housing) metal oxide gapless type with rigid bimetallic terminal connectors as per technical specifications.. 198 kV, 10 KA, class -III, Heavy duty Metal oxide. Note:Surge arrestors are provided with surge monitors & insulating base.No668.67668.676.0FalseNoneNoneFalseNoneFalse4012.020
4067676158223NoneSE9Control and Relay panel Complete SAS Compatible : 220 kV Line panel Type 2L( as per Annexure RPP1-SAS) Note:- Note : 1)The Accuracy class of metering core of CTs and also trivector meter of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents. 2)The proposed C&R Panel shall be interfaced with M/s.Sifang make SAS. 3) The proposed C&R Panel shall be interfaced with existing Bus-bar protection Scheme and Sifang make SAS and also to provide gate way for SLDC integration. 4) SLDC end, KPTCL SCADA will take care. 5) The Electronic Trivector meter with ABT-DLMS features shall be provided for both line TBsNo93785.2293785.222.0FalseNoneNoneFalseNoneFalse187570.440
4067677158223NoneSE10Integration charges with existing SAS system and gatewayLS285560.0285560.02.0FalseNoneNoneFalseNoneFalse571120.00
4067678158223NoneSE11Total Weight of Station structures & Mounting Structures (including Bolts & nuts) Also added Sl. no. SE12 of Station Erection portion) (Refer TechnoCommercial Sheet for details)MT6753.146753.1430.5079FalseNoneNoneFalseNoneFalse206024.1198060
4067679158223NoneSE13Formation of Main/Cross bus with single Drake ACSR 220kV sideNo14262.6614262.662.0FalseNoneNoneFalseNoneFalse28525.320
4067680158223NoneSE14INSULATORS: Post Insulators-Cylindrical Solid Core Insulators as per IS : 5350, Part-II & III & as per technical specification: For 220kV side -2 units/stack Post Insulators of Rigid BusStack667.88667.8824.0FalseNoneNoneFalseNoneFalse16029.120
4067681158223NoneSE15AC Distribution box (out door ): AC distribution Box double front (out door) 24 terminal 1200 x 1350 x 600 mm , 2 I/C of 100 Amps MCCB 20 KA + 24 O/G MCB 16 Amps + 2 O / G of 100 A HRC fuseNo2909.882909.881.0FalseNoneNoneFalseNoneFalse2909.880
4067682158223NoneSE16LT Power Cable: 1.1 kV class PVC insulated Alluminium power cable(AC supply for lighting etc,.) 4 x 70 Sq mm with glands/lugs/ferrulesMtr17.717.7200.0FalseNoneNoneFalseNoneFalse3540.00
4067683158223NoneSE17Laying of PVC insulated Copper Control Cable with Lugs / Ferrules 1.1kV class (Refer TechnoCommercial Sheet for split up)Mtr17700.017700.09.5FalseNoneNoneFalseNoneFalse168150.00
4067684158223NoneSE18PLCC equipments: 1.Wave Trap (suspension type) 0.5mH, 1250A, 31.5 kA, 50-150Hz and 100-500kHzNo4594.924594.924.0FalseNoneNoneFalseNoneFalse18379.680
4067685158223NoneSE192.40 W Carrier cabinet Single channel-40WSet11165.1611165.162.0FalseNoneNoneFalseNoneFalse22330.320
4067686158223NoneSE203.Coupling device MCD 80 LMU+LMDUSet1642.561642.562.0FalseNoneNoneFalseNoneFalse3285.120
4067687158223NoneSE214.Co axial cable 75 OhmKm22420.022420.01.0FalseNoneNoneFalseNoneFalse22420.00
4067688158223NoneSE22Releasing & Reerection of Lightning Mast-1 No.MT6753.146753.142.81FalseNoneNoneFalseNoneFalse18976.32340
4067689158223NoneSE23Earth Mat formation : i. Supplying and laying MS Flat 50 x 6 mm flat welding and applying ACB paint to welded portion as per approved drawing, specification and direction of Engineer in-charge of work.Mtr476.72476.722754.0FalseNoneNoneFalseNoneFalse1312886.880
4067690158223NoneSE24ii.Supplying and Grounding of Equipment and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. G.I.Flat 50x6mmMtr395.3395.31414.0FalseNoneNoneFalseNoneFalse558954.20
4067691158223NoneSE25iii)Supplying and Providing 25mm dia M.S.Rod 1.05m long earthman spikes including heating, bending top 50mm overlap flattening and making spike edge at the ground level and welding the rod with ground mat flat with necessary earth work.No534.54534.54114.0FalseNoneNoneFalseNoneFalse60937.560
4067692158223NoneSE26iv) Erection portion of Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing including the cost of excavation, providing & laying homogeneous mixture of charcoal lumps, salt & sand all round the pipe as per specification .Set4119.384119.3830.0FalseNoneNoneFalseNoneFalse123581.40
17271779600000NoneNoneTransmission LineLine Erection13376242.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067693158224NoneLE1Check Survey and Towers Spotting Towers- all types of Terrain: a Survey using their own equipment including clearing for bushes tree branches upto 3mtr width etc., I For 220kVKm3569.53569.525.567FalseNoneNoneFalseNoneFalse91261.40650
4067694158224NoneLE2ii For 110kVKm3426.723426.722.319FalseNoneNoneFalseNoneFalse7946.563680
4067695158224NoneLE3b Installing insulator strings complete with necessary Hardwares, Installing and stringing of conductor including fixing of conductor accessories, etc., (including all the conductors in each phase of all the circuits) - 220/110kV Line i DRAKE ACSRKm15340.015340.0155.703FalseNoneNoneFalseNoneFalse2388484.020
4067696158224NoneLE4ii Lynx ACSRKm9440.09440.014.123FalseNoneNoneFalseNoneFalse133321.120
4067697158224NoneLE5iii Ground wire for 110kV lineKm12980.012980.02.354FalseNoneNoneFalseNoneFalse30554.920
4067698158224NoneLE6c Installing of OPGW cable along with associated hardware fittings and vibration dampers for Offline Condition. (220kV Line)Km103840.0103840.028.0FalseNoneNoneFalseNoneFalse2907520.00
4067699158224NoneLE7d Tower Accessories required for replacement of existing ground wire by OPGW & Joint box Assembly i. 48 fibre(DWSM)-including installation hardware set for 48 fibre approach cableKm71980.071980.00.5FalseNoneNoneFalseNoneFalse35990.00
4067700158224NoneLE8ii FODP 48 F: Indoor type consisting of 2nos of rack mounted LIU (to be housed in FODP) with 24 ports each with FCPC coupling & pigtailsNo31411.631411.62.0FalseNoneNoneFalseNoneFalse62823.20
4067701158224NoneLE9Erection of Towers (excluding earthing ) Note : 1 The tenderers are required to quote the rates taking in to consideration the charges for sorting of towers parts, loading, unloading, stub seting, fixing of tower accessories,vibration dampers and tack welding etc., 2 The rates shall be on MT basis.MT8471.378471.37722.3381FalseNoneNoneFalseNoneFalse6119193.3101970
4067702158224NoneLE103 Grounding of tower including cost of 40mm dia, 2.5mm thick, class C GI pipe of 3mtrs length as per specifications with 50x6 GI flats 3 mtrs long, salt, charcoal including excavation charges.Set2604.262604.26109.0FalseNoneNoneFalseNoneFalse283864.340
4067703158224NoneLE11Releasing of existing Drake, Lynx Conductor & Ground wire i Releasing of existing Drake conductor - 220kV line portionKm15340.015340.029.58FalseNoneNoneFalseNoneFalse453757.20
4067704158224NoneLE12ii Releasing of existing Lynx conductor - 110kV line portionKm9440.09440.013.944FalseNoneNoneFalseNoneFalse131631.360
4067705158224NoneLE13iii Releasing of existing ground wires a 220kV line portionKm12980.012980.04.96FalseNoneNoneFalseNoneFalse64380.80
4067706158224NoneLE14b 110kV line portionKm12980.012980.02.324FalseNoneNoneFalseNoneFalse30165.520
4067707158224NoneLE15Dismantling of existing 220kV & 110kV Towers Dismantling of existing type tower parts without stubs including loading and unloading from site to store a 220kV Tower : 220kV D/C - 16nosMT6753.146753.1469.491FalseNoneNoneFalseNoneFalse469282.451740
4067708158224NoneLE16b 110kV Tower : 110kV D/C - 8nos Note: a Payment will be made only for the actual weight of towers/conductor length/earth wire length which are dismantled. b Released/dismantled charges shall include loading/unloading and transportation charges. c Released/Dismantled materials shall be transported to nearest KPTCL MW storesMT6753.146753.1424.591FalseNoneNoneFalseNoneFalse166066.465740
17271779600000NoneNoneTransmission LineCivil TB portion18503179.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067709158225NoneCVL TB 1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling, water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.329750.0FalseNoneNoneFalseNoneFalse5453370.00
4067710158225NoneCVL TB 2Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. n all kinds of soils Depth upto 1.5 mCum285.56285.56460.0FalseNoneNoneFalseNoneFalse131357.60
4067711158225NoneCVL TB 3Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum352.82352.8247.0FalseNoneNoneFalseNoneFalse16582.540
4067712158225NoneCVL TB 4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6683.526683.5267.0FalseNoneNoneFalseNoneFalse447795.840
4067713158225NoneCVL TB 5Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundationCum7641.227641.22151.0FalseNoneNoneFalseNoneFalse1153824.220
4067714158225NoneCVL TB 6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88530.0FalseNoneNoneFalseNoneFalse166356.40
4067715158225NoneCVL TB 7Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workCum100.3100.31090.0FalseNoneNoneFalseNoneFalse109327.00
4067716158225NoneCVL TB 8Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structuresKg93.2393.238742.0FalseNoneNoneFalseNoneFalse815016.660
4067717158225NoneCVL TB 9Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg133.34133.342700.0FalseNoneNoneFalseNoneFalse360018.00
4067718158225NoneCVL TB 10Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7539.027539.021106.0FalseNoneNoneFalseNoneFalse8338156.120
4067719158225NoneCVL TB 11Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge.Sqm392.94392.94111.0FalseNoneNoneFalseNoneFalse43616.340
4067720158225NoneCVL TB 12Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregate for copingCum7702.867702.868.0FalseNoneNoneFalseNoneFalse61622.880
4067721158225NoneCVL TB 13Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm205.32205.32141.0FalseNoneNoneFalseNoneFalse28950.120
4067722158225NoneCVL TB 14Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3m484.98484.98245.0FalseNoneNoneFalseNoneFalse118820.10
4067723158225NoneCVL TB 15Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Nos7313.647313.645.0FalseNoneNoneFalseNoneFalse36568.20
4067724158225NoneCVL TB 16Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wirem21.2421.24853.0FalseNoneNoneFalseNoneFalse18117.720
4067725158225NoneCVL TB 17Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia 4 mmSqm947.54947.54425.0FalseNoneNoneFalseNoneFalse402704.50
4067726158225NoneCVL TB 18Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm300.9300.9663.0FalseNoneNoneFalseNoneFalse199496.70
4067727158225NoneCVL TB 19Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer in-charge of works as per the standard procedure.Sqm209.21209.212875.0FalseNoneNoneFalseNoneFalse601478.750
17271779600000NoneNoneTransmission LineCivil Line portion39185442.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4067728158226NoneCVLL1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum125.92125.9212693.0FalseNoneNoneFalseNoneFalse1598302.560
4067729158226NoneCVLL2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth.Cum447.36447.361399.0FalseNoneNoneFalseNoneFalse625856.640
4067730158226NoneCVLL3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth exceeding 1.5 m but not exceeding 3 m depthCum524.3524.32000.0FalseNoneNoneFalseNoneFalse1048600.00
4067731158226NoneCVLL4Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock (requiring blasting) Depth upto 1.50mCum683.55683.55566.0FalseNoneNoneFalseNoneFalse386889.30
4067732158226NoneCVLL5Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 mCum767.96767.96567.0FalseNoneNoneFalseNoneFalse435433.320
4067733158226NoneCVLL6Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum7670.07670.0263.0FalseNoneNoneFalseNoneFalse2017210.00
4067734158226NoneCVLL7Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8375.988375.982037.0FalseNoneNoneFalseNoneFalse17061871.260
4067735158226NoneCVLL8Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structuresKg97.4697.46114914.0FalseNoneNoneFalseNoneFalse11199518.440
4067736158226NoneCVLL9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum328.56328.5614645.0FalseNoneNoneFalseNoneFalse4811761.20
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17271779600000NoneNoneELIGIBILITYTenders from consortium arrangements/Joint ventures are not acceptable.None
17271779600000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17271779600000NoneNoneELIGIBILITYThe Tenderer is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitchesNone
17271779600000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17271779600000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17271779600000NoneNoneELIGIBILITYThe Bidder shall scan the Bank Guarantee towards EMD over and above Rs.10.00Lakh as per Annexure-II of Section-4 and upload the same in the prescribed format in the e-procurement portal to enable the owner for verification of EMD BG at the time of opening of Techno Commercial Bid, failing which the offer will be rejected. Also, the Bidder shall ensure that the Bank Guarantee towards EMD shall be sent in original to the Chief Engineer, Electy., (T&P), KPTCL, Bengaluru, so as to reach after the last date of submission of bid & on or before the date & time notified for opening of Techno Commercial Bids, in a sealed cover, failing which their bid will not be openedNone
17271779600000NoneNoneELIGIBILITYTenderer shall upload the legible documents only.None
17271779600000NoneNoneELIGIBILITYBidder shall not take any deviations on the clauses listed in the No Deviation Certificate(Annexure-I) & Schedule 5 and Schedule 6None
17271779600000NoneNoneELIGIBILITYFilled in Techno commercial sheet shall be uploaded along with all other QR documents. Offers shall be quoted in the item-wise bid Financial offer, provisioned in the e-procurement portal. In case the Prices are uploaded in/along the Techno commercial Bid, then Bid will be summarily rejected. The Techno-commercial sheets shall be uploaded in KPTCL excel formats onlyNone
17271779600000NoneNoneELIGIBILITYAll other terms and conditions as per Tender documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDocumentary proof for clause no.3.2 (b)(i) of ITT,Tenderer such as P.O, LOI/LOA, DWA, Work done, Performance Certificates issued by the end users not below the rank of Executive/ Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- P.O, LOI/LOA, DWA, Work done, Performance Certificates issued by the end users
NoneNoneNoneNoneDocumentary proof for clause no.3.2 (b)(ii) of ITT, Tenderer such as P.O, LOI/LOA, DWA, Work done, Performance Certificates issued by the end users not below the rank of Executive/ Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- P.O, LOI/LOA, DWA, Work done, Performance Certificates issued by the end users
NoneNoneNoneNoneAudited Financial statements i.e Balance sheets, P&L statements, Turnover certificates and Auditors Reports of the last five years preceding the date of bid submission of the Bidder duly certified by chartered Accountant as in clause no.3.2 (a) of ITTFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Audited Financial statements i.e Balance sheets, P&L statements, Turnover certificates and Auditors Reports
NoneNoneNoneNoneBankers Certificate duly signed by authorized person in the prescribed format as at Annexure XVIII of Section-4 and as per the clause no.3.3 (b) of ITT (Liquid Assets and /or availability of credit facilities) for assessing the Liquid Assets (Letter of Credit/ Certificate from banks for meeting fund requirement)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bankers Certificate
NoneNoneNoneNonei.Documentary proof for Clause No: 3.6 of ITT: Assessed available tender capacity such as, Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years taking into account the completed as well as works in progress and the statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent as sought in Note of the said clause and shall be in the prescribed format as in clause No: 1.5 of QIFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed available tender capacity- Relevant documents
NoneNoneNoneNoneOR Documentary proof for Clause No: 3.6 of ITT: Assessed available tender capacity such as, Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years taking into account the completed as well as works in progress and statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be verified and certified by Chartered Accountant/ Cost Auditor. However, the Bidder has to upload the PO/Work Award copies for existing commitments and on-going works as sought in Note of the said clause and shall be in the prescribed format as in clause No: 1.5 of QIFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed available tender capacity - Relevant documents
NoneNoneNoneNoneSelf-declaration as sought in clause no.3.6 Note (ii) of ITT and at clause No.1.5 of Section-3-QI stating that, the information with regard to assessed available tender capacity (Works on Hand) furnished are correct to be uploadedOthersSelf-declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self-declaration-Relevant documents
NoneNoneNoneNoneValid Super grade Electrical Contractors License issued by the Government of Karnataka as on the date of bid submission as per clause no.2.3 of ITT, failing which the offer is liable to be rejectedOthersSuper grade Electrical Contractors License
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents/SGL
NoneNoneNoneNonePower of Attorney in favor of all the persons signing the documents and a certified copy by the Company Secretary/ Authorized Signatory for power of attorney holder shall be attached as evidence for authentication as in Annexure-X1OthersPower of Attorney
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Power of Attorney-Relevant documents
NoneNoneNoneNoneLetter of Undertaking as per Annexure-V of Section-4OthersLetter of Under taking (LOU)
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Letter of Under taking (LOU) -Relevant document
NoneNoneNoneNoneCertificate of Incorporation of the Individual or any relevant document in respect of Partnership/Proprietorship firms as per the tender documentOthersCertificate of Incorporation
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate of Incorporation-Relevant documents
NoneNoneNoneNoneSelf-declarations in respect of Litigation, dis-qualification/Black listed due to non-performance & Risk & cost, Country which shares a land border with India as specified in Annexure XVI and Annexure XVII and as per clause no. 2.3 & 2.4 (b), (c), (d) & (e) of ITTOthersSelf-declarations
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self-declarations -Relevant documents
NoneNoneNoneNoneGST registration, PAN etc., of the Tenderer as per clause no.3.10 (xiii) of ITTOthersGST registration, PAN etc
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST registration, PAN etc-Relevant documents
NoneNoneNoneNoneThe Qualification and experience of key Personnel proposed for carrying out the WorkOtherskey Personnel
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- key Personnel -Relevant documents
NoneNoneNoneNoneDescription of the Tools & Plant available with them for execution of the WorkOthersTools & Plant available
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tools & Plant available -Relevant documents
NoneNoneNoneNoneNo Deviation Certificate as per Annexure-I of Section-4OthersNo Deviation Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents/ Certificate
NoneNoneNoneNoneThe Tenderer shall upload declarations for Deviations, if any as per Schedule-5 and Schedule-6 of the Techno Commercial sheetsOthersTechnical and Commercial Deviations
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Declarations-Relevant documents
NoneNoneNoneNoneCopies of original documents defining the Constitution or legal status, Place of Registration(upload copy) and Principal place of business of the Bidder written Power of Attorney to the Signatory of the Bid to commit the Bidder to the Contract along with the resolution passed in this regard by the Board of Directors / all the Partners of the FirmOthersConstitution or legal status, Place of Registration etc.,
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneInformation on litigations in which the Tenderer is involved as per prescribed format as at 1.12 of Qualification InformationOthersInformation on litigations
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneUndertaking to source the supply of equipment/material from KPTCL approved Vendors only as per the QR for Vendor registration, available in the KPTCL website i.e., https//kptcl.karnataka.gov.in, Link Tendering & Procurement application for Vendor registration etc as per Annexure -XIV of Section-4OthersUndertaking
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents/ Undertaking
NoneNoneNoneNoneCertificate is to be uploaded by the Tenderer agreeing to source the equipment/ material for the work from the Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as per Annexure -XVII of Section-4OthersCertificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents/ Certificate
NoneNoneNoneNoneproposed methodology and program of construction backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per approved Activity chart as per clause No.1.13 of Section-3-Qualification InformationOthersProposed methodology and program of construction
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneType test reports as per tender documents / technical specificationsOthersType test reports
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneAll details as called for in the Technical specifications of all the equipments/ materials of the TenderOthersDocuments as per Technical Specs
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneAny other required documents as per the qualifying requirements, terms and conditions of the tender, NIT & Technical specificationsOthersDocuments as per terms and conditions of the tender
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneFilled in Techno commercial sheet shall be uploaded along with all other QR documents. Offers shall be quoted in the item-wise bid Financial offer, provisioned in the e-procurement portal. In case the Prices are uploaded in/along the Techno commercial Bid, then Bid will be summarily rejected. The Techno-commercial sheets shall be uploaded in KPTCL excel formats onlyOthersBid Proposal Sheets
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Techno commercial sheetsTrueTechnical Bid
OthersTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1727179523000
version0
createdDateNone
modifiedDateNone
blockNumberKPTCL,CAUVERY BHAVAN
streetNone
cityBangalore
stateKarnataka
pin560009