noticeInvitingTenderDTO
createdTs1727261930118
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd975000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-10-2024 16:00:00
tenderQueryClose08-10-2024 16:00:00
technicalBidOpen28-10-2024 16:00:00
publishedDate25-09-2024 19:29:02
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate09-10-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1727261930139
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT296
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Tayakanahalli Village, Kudlagi Taluk, Vijayanagara District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Tayakanahalli Village, Kudlagi Taluk, Vijayanagara District
categoryWORKS
categoryTextWorks
ecv64926557.92
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount64926558.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/317/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17272619300000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School, Tayakanahalli Village, Kudlagi Taluk, Vijayanagara District64926557.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4074158158563Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Comn-SR V-1, Item No - 1.12)Cum99.7599.75222.57FalseNoneNoneFalseNoneFalse22201.35750
4074159158563Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dessing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m .(Comn-SR V-1, Item No - 1.14.1)Cum107.1107.1856.99FalseNoneNoneFalseNoneFalse91783.6290
4074160158563Nonecode03Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Comn-SR V-1, Item No - 1.9)Cum279.3279.3740.47FalseNoneNoneFalseNoneFalse206813.2710
4074161158563Nonecode04Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. (Comn-SR V-2, Item No - 4.1)Sqm123.9123.9568.51FalseNoneNoneFalseNoneFalse70438.3890
4074162158563Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (7.5) Using 40 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.2)Cum5947.25947.2195.16FalseNoneNoneFalseNoneFalse1160655.5520
4074163158563Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.2.2.1) For RCC Column Footing - Add shuttering, cost-8% :Cum7759.967759.96230.81FalseNoneNoneFalseNoneFalse1791076.36760
4074164158563Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)- Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No -2.3.2) - Plinth Beam - Add shuttering, cost-50% :Cum10206.010206.049.15FalseNoneNoneFalseNoneFalse501624.90
4074165158563Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : a. Upto Plinth Lvl and b. Ground floor - Add shuttering, cost-70% :Cum12214.7612214.7644.12FalseNoneNoneFalseNoneFalse538915.21120
4074166158563Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : First floor - Add shuttering, cost-70% :Cum12336.912336.918.59FalseNoneNoneFalseNoneFalse229342.9710
4074167158563Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : Second floor - Add shuttering, cost-70%Cum12459.0512459.0518.59FalseNoneNoneFalseNoneFalse231613.73950
4074168158563Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : Third floor - Add shuttering, cost-70% :Cum12581.212581.218.59FalseNoneNoneFalseNoneFalse233884.5080
4074169158563Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Columns : Fourth floor - Add shuttering, cost-70% :Cum12703.3512703.3518.59FalseNoneNoneFalseNoneFalse236155.27650
4074170158563Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Columns : Fifth floor - Add shuttering, cost-70% :Cum12825.4912825.497.38FalseNoneNoneFalseNoneFalse94652.11620
4074171158563Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Lintel beam : a. Ground floor - Add shuttering, cost-60% :Cum11496.2411496.245.66FalseNoneNoneFalseNoneFalse65068.71840
4074172158563Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : First floor - Add shuttering, cost-60% :Cum11611.211611.29.58FalseNoneNoneFalseNoneFalse111235.2960
4074173158563Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : Second floor - Add shuttering, cost-60% :Cum11726.1611726.169.58FalseNoneNoneFalseNoneFalse112336.61280
4074174158563Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2For RCC Lintel : Third floor - Add shuttering, cost-60% :Cum11841.1211841.129.58FalseNoneNoneFalseNoneFalse113437.92960
4074175158563Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2 For RCC Lintel : Fourth floor - Add shuttering, cost-60% :Cum11956.0911956.099.58FalseNoneNoneFalseNoneFalse114539.34220
4074176158563Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Roof beam : a. Ground floor - Add shuttering, cost-60% :Cum11496.2411496.2439.31FalseNoneNoneFalseNoneFalse451917.19440
4074177158563Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : First floor - Add shuttering, cost-60% :Cum11611.211611.239.31FalseNoneNoneFalseNoneFalse456436.2720
4074178158563Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Second floor - Add shuttering, cost-60% :Cum11726.1611726.1639.31FalseNoneNoneFalseNoneFalse460955.34960
4074179158563Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Third floor - Add shuttering, cost-60% :Cum11841.1211841.1239.31FalseNoneNoneFalseNoneFalse465474.42720
4074180158563Nonecode23Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Fourth floor - Add shuttering, cost-60% :Cum11956.0911956.0939.31FalseNoneNoneFalseNoneFalse469993.89790
4074181158563Nonecode24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof beam : Fifth floor - Add shuttering, cost-60% :Cum12071.0512071.055.65FalseNoneNoneFalseNoneFalse68201.43250
4074182158563Nonecode25Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Roof Slab : a. Ground floor - Add shuttering, cost-50% :Cum10777.7310777.7391.98FalseNoneNoneFalseNoneFalse991335.60540
4074183158563Nonecode26Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : First floor - Add shuttering, cost-50% :Cum10885.510885.589.21FalseNoneNoneFalseNoneFalse971095.4550
4074184158563Nonecode27Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Second floor - Add shuttering, cost-50% :Cum10993.2810993.2889.21FalseNoneNoneFalseNoneFalse980710.50880
4074185158563Nonecode28Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Third floor - Add shuttering, cost-50% :Cum11101.0511101.0589.21FalseNoneNoneFalseNoneFalse990324.67050
4074186158563Nonecode29Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Fourth floor - Add shuttering, cost-50% :Cum11208.8411208.8489.21FalseNoneNoneFalseNoneFalse999940.61640
4074187158563Nonecode30Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Roof slab : Fifth floor - Add shuttering, cost-50% :Cum11316.311316.38.06FalseNoneNoneFalseNoneFalse91209.3780
4074188158563Nonecode31Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Staircase : a. Ground floor to First floor - Add shuttering, cost-50% :Cum10777.7310777.735.35FalseNoneNoneFalseNoneFalse57660.85550
4074189158563Nonecode32Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : First floor to Second floor - Add shuttering, cost-50% :Cum10885.510885.55.0FalseNoneNoneFalseNoneFalse54427.50
4074190158563Nonecode33Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Second floor to Third floor - Add shuttering, cost-50% :Cum10993.2810993.285.0FalseNoneNoneFalseNoneFalse54966.40
4074191158563Nonecode34Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Third floor to Fourth floor - Add shuttering, cost-50% :Cum11101.0511101.055.0FalseNoneNoneFalseNoneFalse55505.250
4074192158563Nonecode35Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Staircase : Fourth floor to Fifth (Terrace) floor - Add shuttering, cost-50% :Cum11208.8411208.845.0FalseNoneNoneFalseNoneFalse56044.20
4074193158563Nonecode36Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Chejja's & Sill : a. Ground floor - Add shuttering, cost-45% :Cum10418.4710418.475.68FalseNoneNoneFalseNoneFalse59176.90960
4074194158563Nonecode37Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : First floor - Add shuttering, cost-45% :Cum10522.6510522.655.2FalseNoneNoneFalseNoneFalse54717.780
4074195158563Nonecode38Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : Second floor - Add shuttering, cost-45% :Cum10626.8310626.835.2FalseNoneNoneFalseNoneFalse55259.5160
4074196158563Nonecode39Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2) For RCC Chejja's & Sill : Third floor - Add shuttering, cost-45% :Cum10731.0210731.025.2FalseNoneNoneFalseNoneFalse55801.3040
4074197158563Nonecode40Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Comn-SR V-1, Item No -2.5.2)For RCC Chejja's & Sill : Fourth floor - Add shuttering, cost-45% :Cum10835.2110835.215.2FalseNoneNoneFalseNoneFalse56343.0920
4074198158563Nonecode41Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a) a. Ground floorTonne93929.8593929.8555.22FalseNoneNoneFalseNoneFalse5186806.3170
4074199158563Nonecode42Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a) First FloorTonne94869.1594869.1522.45FalseNoneNoneFalseNoneFalse2129812.41750
4074200158563Nonecode43Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Second FloorTonne95808.4595808.4522.45FalseNoneNoneFalseNoneFalse2150899.70250
4074201158563Nonecode44Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Third FloorTonne96747.7596747.7522.45FalseNoneNoneFalseNoneFalse2171986.98750
4074202158563Nonecode45Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Fourth FloorTonne97687.0497687.0422.45FalseNoneNoneFalseNoneFalse2193074.0480
4074203158563Nonecode46Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Comn-SR V-1, Item No -2.11.a)Fifth Floor or Terrace FloorTonne98626.3498626.343.72FalseNoneNoneFalseNoneFalse366889.98480
4074204158563Nonecode47Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator Sill : a. Ground floor - Add shuttering, cost-45% :Cum10444.5610444.561.54FalseNoneNoneFalseNoneFalse16084.62240
4074205158563Nonecode48Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : First floor - Add shuttering, cost-45% :Cum10549.0110549.011.43FalseNoneNoneFalseNoneFalse15085.08430
4074206158563Nonecode49Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Second floor - Add shuttering, cost-45% :Cum10653.4510653.451.43FalseNoneNoneFalseNoneFalse15234.43350
4074207158563Nonecode50Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Third floor - Add shuttering, cost-45% :Cum10757.910757.91.43FalseNoneNoneFalseNoneFalse15383.7970
4074208158563Nonecode51Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Comn-SR V-1, Item No - 2.1.4) For RCC Window & Ventilator - Sill : Fourth floor - Add shuttering, cost-45% :Cum10862.3410862.341.43FalseNoneNoneFalseNoneFalse15533.14620
4074209158563Nonecode52Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Comn-SR V-2, Item No - 5.4)Cum6708.456708.4544.31FalseNoneNoneFalseNoneFalse297251.41950
4074210158563Nonecode53Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) a. Ground floorSqm1375.51375.5202.8FalseNoneNoneFalseNoneFalse278951.40
4074211158563Nonecode54Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) First FloorSqm1389.261389.26194.76FalseNoneNoneFalseNoneFalse270572.27760
4074212158563Nonecode55Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Second FloorSqm1403.011403.01194.76FalseNoneNoneFalseNoneFalse273250.22760
4074213158563Nonecode56Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Third FloorSqm1416.771416.77194.76FalseNoneNoneFalseNoneFalse275930.12520
4074214158563Nonecode57Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32)Fourth FloorSqm1430.521430.52194.76FalseNoneNoneFalseNoneFalse278608.07520
4074215158563Nonecode58Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Comn-SR V-2, Item No - 6.32) Fifth Floor or Terrace FloorSqm1444.281444.28141.24FalseNoneNoneFalseNoneFalse203990.10720
4074216158563Nonecode59Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33) a. Ground floorSqm1292.551292.55209.41FalseNoneNoneFalseNoneFalse270672.89550
4074217158563Nonecode60Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33) First FloorSqm1305.481305.48314.8566FalseNoneNoneFalseNoneFalse411038.9941680
4074218158563Nonecode61Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Second FloorSqm1318.41318.4316.02FalseNoneNoneFalseNoneFalse416640.7680
4074219158563Nonecode62Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Third FloorSqm1331.331331.33316.02FalseNoneNoneFalseNoneFalse420726.90660
4074220158563Nonecode63Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.33)Fourth FloorSqm1344.251344.25316.02FalseNoneNoneFalseNoneFalse424809.8850
4074221158563Nonecode64Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34) a. Ground floorSqm1159.21159.276.09FalseNoneNoneFalseNoneFalse88203.5280
4074222158563Nonecode65Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)First FloorSqm1170.791170.7960.94FalseNoneNoneFalseNoneFalse71347.94260
4074223158563Nonecode66Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)Second FloorSqm1182.381182.3860.94FalseNoneNoneFalseNoneFalse72054.23720
4074224158563Nonecode67Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34)Third FloorSqm1193.981193.9860.94FalseNoneNoneFalseNoneFalse72761.14120
4074225158563Nonecode68Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Comn-SR V-2, Item No - 6.34) Fourth FloorSqm1205.571205.5760.94FalseNoneNoneFalseNoneFalse73467.43580
4074226158563Nonecode69Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) a. Ground floorCum103755.75103755.751.42FalseNoneNoneFalseNoneFalse147333.1650
4074227158563Nonecode70Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) First FloorCum104793.31104793.311.61FalseNoneNoneFalseNoneFalse168717.22910
4074228158563Nonecode71Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Second FloorCum105830.87105830.871.61FalseNoneNoneFalseNoneFalse170387.70070
4074229158563Nonecode72Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Third FloorCum106868.42106868.421.61FalseNoneNoneFalseNoneFalse172058.15620
4074230158563Nonecode73Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Fourth FloorCum107905.98107905.981.61FalseNoneNoneFalseNoneFalse173728.62780
4074231158563Nonecode74Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Comn-SR V-2, Item No - 12.13.1) Fifth FloorCum108943.54108943.540.12FalseNoneNoneFalseNoneFalse13073.22480
4074232158563Nonecode75Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) a. Ground floorNos1066.81066.810.0FalseNoneNoneFalseNoneFalse10668.00
4074233158563Nonecode76Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) First FloorNos1077.471077.4713.0FalseNoneNoneFalseNoneFalse14007.110
4074234158563Nonecode77Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Second FloorNos1088.141088.1413.0FalseNoneNoneFalseNoneFalse14145.820
4074235158563Nonecode78Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Third FloorNos1098.81098.813.0FalseNoneNoneFalseNoneFalse14284.40
4074236158563Nonecode79Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51)Fourth FloorNos1109.471109.4713.0FalseNoneNoneFalseNoneFalse14423.110
4074237158563Nonecode80Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Comn-SR V-2, Item No -12.51) Fifth FloorNos1120.141120.141.0FalseNoneNoneFalseNoneFalse1120.140
4074238158563Nonecode81Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) a. Ground floorSqm5208.05208.033.6FalseNoneNoneFalseNoneFalse174988.80
4074239158563Nonecode82Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) First FloorSqm5260.085260.0831.2FalseNoneNoneFalseNoneFalse164114.4960
4074240158563Nonecode83Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Second FloorSqm5312.165312.1631.2FalseNoneNoneFalseNoneFalse165739.3920
4074241158563Nonecode84Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Third FloorSqm5364.245364.2431.2FalseNoneNoneFalseNoneFalse167364.2880
4074242158563Nonecode85Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Fourth FloorSqm5416.325416.3231.2FalseNoneNoneFalseNoneFalse168989.1840
4074243158563Nonecode86Providing and fixing flush door shutter made out of solid core block board type 40 mm thick Both side teak, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Comn-SR V-2, Item No - 12.57.7) Fifth FloorSqm5468.45468.42.4FalseNoneNoneFalseNoneFalse13124.160
4074244158563Nonecode87Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) a. Ground floorm737.1737.125.05FalseNoneNoneFalseNoneFalse18464.3550
4074245158563Nonecode88Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) First Floorm744.47744.4799.0FalseNoneNoneFalseNoneFalse73702.530
4074246158563Nonecode89Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Second Floorm751.84751.8499.0FalseNoneNoneFalseNoneFalse74432.160
4074247158563Nonecode90Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Third Floorm759.21759.2199.0FalseNoneNoneFalseNoneFalse75161.790
4074248158563Nonecode91Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (Comn-SR V-2, Item No 12.93.1) Fourth Floorm766.58766.5899.0FalseNoneNoneFalseNoneFalse75891.420
4074249158563Nonecode92Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) a. Ground floorSqm3659.253659.258.51FalseNoneNoneFalseNoneFalse31140.21750
4074250158563Nonecode93Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) First FloorSqm3695.843695.8431.5FalseNoneNoneFalseNoneFalse116418.960
4074251158563Nonecode94Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Second FloorSqm3732.443732.4431.5FalseNoneNoneFalseNoneFalse117571.860
4074252158563Nonecode95Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Third FloorSqm3769.033769.0331.5FalseNoneNoneFalseNoneFalse118724.4450
4074253158563Nonecode96Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with ecessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness. (Comn-SR V-2, Item No - 12.94.1) Fourth FloorSqm3805.623805.6231.5FalseNoneNoneFalseNoneFalse119877.030
4074254158563Nonecode97Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) a. Ground floorSqm7070.77070.756.7FalseNoneNoneFalseNoneFalse400908.690
4074255158563Nonecode98Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) First FloorSqm7141.417141.4137.8FalseNoneNoneFalseNoneFalse269945.2980
4074256158563Nonecode99Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Second FloorSqm7212.117212.1137.8FalseNoneNoneFalseNoneFalse272617.7580
4074257158563Nonecode100Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Third FloorSqm7282.827282.8237.8FalseNoneNoneFalseNoneFalse275290.5960
4074258158563Nonecode101Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Comn-SR V-2, Item No -12.90) Fourth FloorSqm7353.537353.5337.8FalseNoneNoneFalseNoneFalse277963.4340
4074259158563Nonecode102Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) a. Ground floorSqm6004.956004.950.9FalseNoneNoneFalseNoneFalse5404.4550
4074260158563Nonecode103Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) First FloorSqm6065.06065.019.62FalseNoneNoneFalseNoneFalse118995.30
4074261158563Nonecode104Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Second FloorSqm6125.056125.0519.62FalseNoneNoneFalseNoneFalse120173.4810
4074262158563Nonecode105Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Third FloorSqm6185.16185.119.62FalseNoneNoneFalseNoneFalse121351.6620
4074263158563Nonecode106Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (Comn-SR V-2, Item No -12.85) Fourth FloorSqm6245.156245.1519.62FalseNoneNoneFalseNoneFalse122529.8430
4074264158563Nonecode107Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) a. Ground floorKgs176.4176.41330.56FalseNoneNoneFalseNoneFalse234710.7840
4074265158563Nonecode108Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) First FloorKgs178.16178.161205.82FalseNoneNoneFalseNoneFalse214828.89120
4074266158563Nonecode109Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Second FloorKgs179.93179.931205.82FalseNoneNoneFalseNoneFalse216963.19260
4074267158563Nonecode110Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Third FloorKgs181.69181.691205.82FalseNoneNoneFalseNoneFalse219085.43580
4074268158563Nonecode111Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Comn-SR V-2, Item No -11.34A) Fourth FloorKgs183.46183.461205.82FalseNoneNoneFalseNoneFalse221219.73720
4074269158563Nonecode112Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) a. Ground floorKgs593.25593.25432.0FalseNoneNoneFalseNoneFalse256284.00
4074270158563Nonecode113Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) First FloorKgs599.18599.18396.0FalseNoneNoneFalseNoneFalse237275.280
4074271158563Nonecode114Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Second FloorKgs605.12605.12396.0FalseNoneNoneFalseNoneFalse239627.520
4074272158563Nonecode115Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Third FloorKgs611.05611.05396.0FalseNoneNoneFalseNoneFalse241975.80
4074273158563Nonecode116Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts. (Comn-SR V-2, Item No -11.28) Fourth FloorKgs616.98616.98396.0FalseNoneNoneFalseNoneFalse244324.080
4074274158563Nonecode117Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) For Ceiling a. Ground floorSqm267.75267.75490.3FalseNoneNoneFalseNoneFalse131277.8250
4074275158563Nonecode118Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) First FloorSqm270.41270.41471.82FalseNoneNoneFalseNoneFalse127584.84620
4074276158563Nonecode119Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Second FloorSqm273.11273.11471.82FalseNoneNoneFalseNoneFalse128858.76020
4074277158563Nonecode120Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Third FloorSqm275.78275.78471.82FalseNoneNoneFalseNoneFalse130118.51960
4074278158563Nonecode121Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Fourth FloorSqm278.46278.46471.82FalseNoneNoneFalseNoneFalse131382.99720
4074279158563Nonecode122Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.1.1) Fifth FloorSqm281.14281.1450.11FalseNoneNoneFalseNoneFalse14087.92540
4074280158563Nonecode123Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall a. Ground floorSqm292.95292.951026.28FalseNoneNoneFalseNoneFalse300648.7260
4074281158563Nonecode124Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall First FloorSqm295.88295.881561.26FalseNoneNoneFalseNoneFalse461945.60880
4074282158563Nonecode125Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wallSecond FloorSqm298.81298.811561.26FalseNoneNoneFalseNoneFalse466520.10060
4074283158563Nonecode126Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Third FloorSqm301.74301.741561.26FalseNoneNoneFalseNoneFalse471094.59240
4074284158563Nonecode127Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Fourth FloorSqm304.67304.671561.26FalseNoneNoneFalseNoneFalse475669.08420
4074285158563Nonecode128Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.2.2) For Inside wall Fifth FloorSqm307.6307.681.88FalseNoneNoneFalseNoneFalse25186.2880
4074286158563Nonecode129Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) a. Ground floorSqm105.0105.01516.58FalseNoneNoneFalseNoneFalse159240.90
4074287158563Nonecode130Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) First FloorSqm106.05106.052033.08FalseNoneNoneFalseNoneFalse215608.1340
4074288158563Nonecode131Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Second FloorSqm107.1107.12033.08FalseNoneNoneFalseNoneFalse217742.8680
4074289158563Nonecode132Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Third FloorSqm108.15108.152033.08FalseNoneNoneFalseNoneFalse219877.6020
4074290158563Nonecode133Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Fourth FloorSqm109.2109.22033.08FalseNoneNoneFalseNoneFalse222012.3360
4074291158563Nonecode134Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Comn-SR V-2, Item No -8.51) Fifth FloorSqm110.25110.25131.99FalseNoneNoneFalseNoneFalse14551.89750
4074292158563Nonecode135Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall a. Ground floorSqm404.25404.25447.96FalseNoneNoneFalseNoneFalse181087.830
4074293158563Nonecode136Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall First FloorSqm408.29408.29451.56FalseNoneNoneFalseNoneFalse184367.43240
4074294158563Nonecode137Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Second FloorSqm412.34412.34451.56FalseNoneNoneFalseNoneFalse186196.25040
4074295158563Nonecode138Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Third FloorSqm416.38416.38451.56FalseNoneNoneFalseNoneFalse188020.55280
4074296158563Nonecode139Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Fourth FloorSqm420.42420.42451.56FalseNoneNoneFalseNoneFalse189844.85520
4074297158563Nonecode140Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Comn-SR V-2, Item No -8.9) For External wall Fifth FloorSqm424.46424.46446.65FalseNoneNoneFalseNoneFalse189585.0590
4074298158563Nonecode141Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) ground floorSqm165.9165.91516.58FalseNoneNoneFalseNoneFalse251600.6220
4074299158563Nonecode142Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) first floorSqm167.56167.562033.08FalseNoneNoneFalseNoneFalse340662.88480
4074300158563Nonecode143Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) second floorSqm169.22169.222033.08FalseNoneNoneFalseNoneFalse344037.79760
4074301158563Nonecode144Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) third floorSqm170.88170.882033.08FalseNoneNoneFalseNoneFalse347412.71040
4074302158563Nonecode145Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) fourth floorSqm172.54172.542033.08FalseNoneNoneFalseNoneFalse350787.62320
4074303158563Nonecode146Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (Comn-SR V-2, Item No -8.33.1) fifth floorSqm174.2174.2131.99FalseNoneNoneFalseNoneFalse22992.6580
4074304158563Nonecode147Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) ground floorSqm55.6555.65447.96FalseNoneNoneFalseNoneFalse24928.9740
4074305158563Nonecode148Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) first floorSqm56.2156.21451.56FalseNoneNoneFalseNoneFalse25382.18760
4074306158563Nonecode149Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) second floorSqm56.7656.76451.56FalseNoneNoneFalseNoneFalse25630.54560
4074307158563Nonecode150Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) third floorSqm57.3257.32451.56FalseNoneNoneFalseNoneFalse25883.41920
4074308158563Nonecode151Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) fourth floorSqm57.8857.88451.56FalseNoneNoneFalseNoneFalse26136.29280
4074309158563Nonecode152Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.27) fifth floorSqm58.4358.43446.65FalseNoneNoneFalseNoneFalse26097.75950
4074310158563Nonecode153Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ ground floorSqm182.7182.7447.96FalseNoneNoneFalseNoneFalse81842.2920
4074311158563Nonecode154Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) : @ first floorSqm184.53184.53451.56FalseNoneNoneFalseNoneFalse83326.36680
4074312158563Nonecode155Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ second floorSqm186.35186.35451.56FalseNoneNoneFalseNoneFalse84148.2060
4074313158563Nonecode156Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ third floorSqm188.18188.18451.56FalseNoneNoneFalseNoneFalse84974.56080
4074314158563Nonecode157Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ fourth floorSqm190.01190.01451.56FalseNoneNoneFalseNoneFalse85800.91560
4074315158563Nonecode158Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.30) @ fifth floorSqm191.84191.84446.65FalseNoneNoneFalseNoneFalse85685.3360
4074316158563Nonecode159Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ ground floorSqm120.75120.75126.72FalseNoneNoneFalseNoneFalse15301.440
4074317158563Nonecode160Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ first floorSqm121.96121.96114.84FalseNoneNoneFalseNoneFalse14005.88640
4074318158563Nonecode161Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ second floorSqm123.17123.17114.84FalseNoneNoneFalseNoneFalse14144.84280
4074319158563Nonecode162Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ third floorSqm124.37124.37114.84FalseNoneNoneFalseNoneFalse14282.65080
4074320158563Nonecode163Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Comn-SR V-2, Item No -8.40) Window & Ventilator Grills @ fourth floorSqm125.58125.58114.84FalseNoneNoneFalseNoneFalse14421.60720
4074321158563Nonecode164Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ ground floorSqm2589.32589.3394.36FalseNoneNoneFalseNoneFalse1021116.3480
4074322158563Nonecode165Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ first floorSqm2615.192615.19115.08FalseNoneNoneFalseNoneFalse300956.06520
4074323158563Nonecode166Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ second floorSqm2641.092641.09115.08FalseNoneNoneFalseNoneFalse303936.63720
4074324158563Nonecode167Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ third floorSqm2666.982666.98115.08FalseNoneNoneFalseNoneFalse306916.05840
4074325158563Nonecode168Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (Comn-SR V-2, Item No -9.23) @ fourth floorSqm2692.872692.87115.08FalseNoneNoneFalseNoneFalse309895.47960
4074326158563Nonecode169Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ ground floorSqm1202.251202.25136.02FalseNoneNoneFalseNoneFalse163530.0450
4074327158563Nonecode170Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ first floorSqm1214.271214.27311.87FalseNoneNoneFalseNoneFalse378694.38490
4074328158563Nonecode171Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ second floorSqm1226.31226.3311.87FalseNoneNoneFalseNoneFalse382446.1810
4074329158563Nonecode172Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ third floorSqm1238.321238.32311.87FalseNoneNoneFalseNoneFalse386194.85840
4074330158563Nonecode173Providing and laying vitrified floor tiles Size of Tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.12.2) @ fourth floorSqm1250.341250.34311.87FalseNoneNoneFalseNoneFalse389943.53580
4074331158563Nonecode174Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ ground floorSqm933.45933.4528.04FalseNoneNoneFalseNoneFalse26173.9380
4074332158563Nonecode175Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ first floorSqm942.78942.7894.5FalseNoneNoneFalseNoneFalse89092.710
4074333158563Nonecode176Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ second floorSqm952.12952.1294.5FalseNoneNoneFalseNoneFalse89975.340
4074334158563Nonecode177Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ third floorSqm961.45961.4594.5FalseNoneNoneFalseNoneFalse90857.0250
4074335158563Nonecode178Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (Comn-SR V-2, Item No -9.11) @ fourth floorSqm970.79970.7994.5FalseNoneNoneFalseNoneFalse91739.6550
4074336158563Nonecode179Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ ground floorSqm1161.31161.347.99FalseNoneNoneFalseNoneFalse55730.7870
4074337158563Nonecode180Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ first floorSqm1172.911172.91264.39FalseNoneNoneFalseNoneFalse310105.67490
4074338158563Nonecode181Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ second floorSqm1184.531184.53264.39FalseNoneNoneFalseNoneFalse313177.88670
4074339158563Nonecode182Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ third floorSqm1196.141196.14264.39FalseNoneNoneFalseNoneFalse316247.45460
4074340158563Nonecode183Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (Comn-SR V-2, Item No -10.14) @ fourth floorSqm1207.751207.75264.39FalseNoneNoneFalseNoneFalse319317.02250
4074341158563Nonecode184Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm866.43866.4353.98FalseNoneNoneFalseNoneFalse46769.89140
4074342158563Nonecode185Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm875.01875.0153.98FalseNoneNoneFalseNoneFalse47233.03980
4074343158563Nonecode186Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm883.59883.5953.98FalseNoneNoneFalseNoneFalse47696.18820
4074344158563Nonecode187Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm892.16892.1653.98FalseNoneNoneFalseNoneFalse48158.79680
4074345158563Nonecode188Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ( UNI-SR-V-2, Item No - 15.1 ) @ first floor levelSqm900.74900.74532.54FalseNoneNoneFalseNoneFalse479680.07960
4074346158563Nonecode189Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete (Comn-SR V-2, Item No - 12.74.1) 125x64x1.90mm : all floorsNos107.1107.1198.0FalseNoneNoneFalseNoneFalse21205.80
4074347158563Nonecode190Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Comn-SR V-2, Item No - 12.72) : all floorsEach86.186.166.0FalseNoneNoneFalseNoneFalse5682.60
4074348158563Nonecode191Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Comn-SR V-2, Item No - 12.73.1) : all floorsEach46.246.266.0FalseNoneNoneFalseNoneFalse3049.20
4074349158563Nonecode192Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(Comn-SR V-2, Item No - 12.60) : all floorsEach1104.61104.666.0FalseNoneNoneFalseNoneFalse72903.60
4074350158563Nonecode193Providing & applying high strength non shrink free flow grout (confirming to BS 1881-Part 116 : 1983)comprising of blend of portland cement, graded fillars and chemical additives which impart controlled expansion in the plastic state duly minimizing water demand. (Minimum 25mm thickness around the pipe) (P.No.299, I.No 38.29 of PW, P&IWTD SR 18-19 ) : all floorsNos257.25257.25170.0FalseNoneNoneFalseNoneFalse43732.50
4074351158563Nonecode194Providing and laying cement concrete flooring 40mm thick,with 20mm nominal size stone aggregates using 1:2:4 ( Cement : 2 corse sand : 4 graded stone aggregates) finished with a floating coat of neat cement, including cement slurry complete. (Page No.59 Item No.9.1) : flagging concreteSqm473.55473.55125.3FalseNoneNoneFalseNoneFalse59335.8150
4074352158563Nonecode195Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) for all floorsEach3030.33030.365.0FalseNoneNoneFalseNoneFalse196969.50
4074353158563Nonecode196Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete.(Comn-SR V-2, Item No - 14.44) all floorsEach11785.211785.245.0FalseNoneNoneFalseNoneFalse530334.00
4074354158563Nonecode197Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. (Market Rate) all floorsNos3000.03000.061.0FalseNoneNoneFalseNoneFalse183000.00
4074355158563Nonecode198Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class (Comn-SR V-2, Item No - 14.60.a) EconomyNos4184.254184.2542.0FalseNoneNoneFalseNoneFalse175738.50
4074356158563Nonecode199Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (Comn-SR V-2, Item No - 13.12)Nos666.75666.7550.0FalseNoneNoneFalseNoneFalse33337.50
4074357158563Nonecode200Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(Comn-SR V-2, Item No - 13.15)Nos761.25761.25203.0FalseNoneNoneFalseNoneFalse154533.750
4074358158563Nonecode201Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31)Each1281.01281.065.0FalseNoneNoneFalseNoneFalse83265.00
4074359158563Nonecode202Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class(Comn-SR V-2, Item No - 14.92a) EconomyNos753.9753.965.0FalseNoneNoneFalseNoneFalse49003.50
4074360158563Nonecode203Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.(Comn-SR V-2, Item No - 14.10)Each5898.95898.92.0FalseNoneNoneFalseNoneFalse11797.80
4074361158563Nonecode204Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangementsv& all necessary accesories complete - Class (Comn-SR V-2, Item No - 14.62a)EconomyNos2024.42024.42.0FalseNoneNoneFalseNoneFalse4048.80
4074362158563Nonecode205600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2)Each520.8520.842.0FalseNoneNoneFalseNoneFalse21873.60
4074363158563Nonecode206Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28)Each96.696.665.0FalseNoneNoneFalseNoneFalse6279.00
4074364158563Nonecode207Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1)Mtr231.0231.0250.0FalseNoneNoneFalseNoneFalse57750.00
4074365158563Nonecode208Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8)Each70.3570.3550.0FalseNoneNoneFalseNoneFalse3517.50
4074366158563Nonecode209Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9)Each201.6201.650.0FalseNoneNoneFalseNoneFalse10080.00
4074367158563Nonecode210Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6)Each122.85122.8550.0FalseNoneNoneFalseNoneFalse6142.50
4074368158563Nonecode211Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7)Mtr431.55431.55180.0FalseNoneNoneFalseNoneFalse77679.00
4074369158563Nonecode212Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8)Each179.55179.5540.0FalseNoneNoneFalseNoneFalse7182.00
4074370158563Nonecode213Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8)Each317.1317.140.0FalseNoneNoneFalseNoneFalse12684.00
4074371158563Nonecode214Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8)Each263.55263.5540.0FalseNoneNoneFalseNoneFalse10542.00
4074372158563Nonecode215Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Comn-SR V-2, Item No - 13.63)Each256.2256.2145.0FalseNoneNoneFalseNoneFalse37149.00
4074373158563Nonecode216Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid. (Comn-SR V-2, Item No - 13.22.2)Nos212.1212.1145.0FalseNoneNoneFalseNoneFalse30754.50
4074374158563Nonecode217Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia(MR)Nos720.0720.0100.0FalseNoneNoneFalseNoneFalse72000.00
4074375158563Nonecode218Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2)Mtr397.95397.95375.0FalseNoneNoneFalseNoneFalse149231.250
4074376158563Nonecode219Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc., 25mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3)Mtr500.85500.85170.0FalseNoneNoneFalseNoneFalse85144.50
4074377158563Nonecode220Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 20mm nominal bore(Comn-SR V-2, Item No - 13.5.2)Mtr329.7329.74.0FalseNoneNoneFalseNoneFalse1318.80
4074378158563Nonecode221Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3)Mtr348.6348.620.0FalseNoneNoneFalseNoneFalse6972.00
4074379158563Nonecode222Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2)Mtr227.85227.85200.0FalseNoneNoneFalseNoneFalse45570.00
4074380158563Nonecode223Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3)Mtr310.8310.8131.0FalseNoneNoneFalseNoneFalse40714.80
4074381158563Nonecode224Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4)Mtr390.6390.6298.0FalseNoneNoneFalseNoneFalse116398.80
4074382158563Nonecode225Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 40 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.5)Mtr500.85500.8572.0FalseNoneNoneFalseNoneFalse36061.20
4074383158563Nonecode226Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 50 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.6)Mtr757.05757.05120.0FalseNoneNoneFalseNoneFalse90846.00
4074384158563Nonecode227Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: (Comn-SR V-1, Item No -13.5) 20mm nominal bore (Comn-SR V-1, 13.5.2)Nos329.7329.710.0FalseNoneNoneFalseNoneFalse3297.00
4074385158563Nonecode228Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 25mm nominal bore (Comn-SR V-1, 13.4.1)Nos576.45576.458.0FalseNoneNoneFalseNoneFalse4611.60
4074386158563Nonecode229Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 32mm nominal bore (Comn-SR V-1, 13.4.2)Nos627.9627.98.0FalseNoneNoneFalseNoneFalse5023.20
4074387158563Nonecode230Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 40mm nominal bore (Comn-SR V-1, 13.4.3)Nos737.1737.110.0FalseNoneNoneFalseNoneFalse7371.00
4074388158563Nonecode231Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 50mm nominal bore (Comn-SR V-1, 13.4.4)Nos897.75897.7510.0FalseNoneNoneFalseNoneFalse8977.50
4074389158563Nonecode232Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(Comn-SR V-1, Item No -13.34)Ltr9.459.4515000.0FalseNoneNoneFalseNoneFalse141750.00
4074390158563Nonecode233Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia (MR)Nos4334.04334.02.0FalseNoneNoneFalseNoneFalse8668.00
4074391158563Nonecode234Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC GratingNos830.0830.010.0FalseNoneNoneFalseNoneFalse8300.00
4074392158563Nonecode235Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5)Mtr231.0231.0361.0FalseNoneNoneFalseNoneFalse83391.00
4074393158563Nonecode236Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6)Each70.3570.3555.0FalseNoneNoneFalseNoneFalse3869.250
4074394158563Nonecode237Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6)Each201.6201.655.0FalseNoneNoneFalseNoneFalse11088.00
4074395158563Nonecode238Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6)Each122.85122.8555.0FalseNoneNoneFalseNoneFalse6756.750
4074396158563Nonecode239Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7)Mtr431.55431.55430.0FalseNoneNoneFalseNoneFalse185566.50
4074397158563Nonecode240Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8)Each179.55179.5550.0FalseNoneNoneFalseNoneFalse8977.50
4074398158563Nonecode241Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9)110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8)Each317.1317.140.0FalseNoneNoneFalseNoneFalse12684.00
4074399158563Nonecode242Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8)Each263.55263.5540.0FalseNoneNoneFalseNoneFalse10542.00
4074400158563Nonecode243Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 160 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.9Mtr648.9648.9123.0FalseNoneNoneFalseNoneFalse79814.70
4074401158563Nonecode244Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 160mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.10)Each351.75351.7515.0FalseNoneNoneFalseNoneFalse5276.250
4074402158563Nonecode245Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 160mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.10)Each494.55494.5515.0FalseNoneNoneFalseNoneFalse7418.250
4074403158563Nonecode246Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 160 mm dia PVC Tee (Comn-SR V-5, Item No -10.10.10)Each489.3489.315.0FalseNoneNoneFalseNoneFalse7339.50
4074404158563Nonecode247Constructing brick masonry chamber of internal dimension 300x230mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Comn-SR V-5,Item No - 16.12)Each2911.652911.659.0FalseNoneNoneFalseNoneFalse26204.850
4074405158563Nonecode248Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Comn-SR V-5,Item No - 16.9)Each5726.75726.715.0FalseNoneNoneFalseNoneFalse85900.50
4074406158563Nonecode249Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.3 M depth & SFRC cover & frame. .(Comn-SR V-5,Item No -16.15.4)Each36423.4536423.452.0FalseNoneNoneFalseNoneFalse72846.90
4074407158563Nonecode250Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling,available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m m3 (Comn-SR V-1, Item No -1.6.1)Cum508.2508.2244.35FalseNoneNoneFalseNoneFalse124178.670
4074408158563Nonecode251Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.(Comn-SR V-1,Item No -1.10)Cum168.0168.0244.35FalseNoneNoneFalseNoneFalse41050.80
4074409158563Nonecode252Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore(Comn-SR V-2,Item No -13.6.3.2)Nos1286.251286.252.0FalseNoneNoneFalseNoneFalse2572.50
4074410158563Nonecode253Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(Comn-SR V-5,Item No -7.5.1) For DI/CI puddle flanges of 80mm dia.Each1659.01659.02.0FalseNoneNoneFalseNoneFalse3318.00
4074411158563Nonecode254Supplying, Intallation, testing and conmissioning of Solar Hot water Heater comprising of solar flat plat collector (FPC) of size 2120 x104 x100mm and stainless steel hot water storage tank with stainless steel Heat exchanges absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity with electrical back up arrangement excluding inlet and outlet pipes. SS model with 100mm thick of 48kg/Cum density rock wool insulation with 22WG Aluminium cladding. '300 Ltrs Capacity. (ELE SR 2-23-24)(7.3.3)Each74955.0174955.015.0FalseNoneNoneFalseNoneFalse374775.050
4074412158563Nonecode255Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Item No 2.2.1 & Page No 4Point282.45282.45330.0FalseNoneNoneFalseNoneFalse93208.50
4074413158563Nonecode256Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box Item No 2.2.2 & Page No 4Point397.95397.95138.0FalseNoneNoneFalseNoneFalse54917.10
4074414158563Nonecode257Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Item No 2.2.3 & Page No 4Point582.75582.75208.0FalseNoneNoneFalseNoneFalse121212.00
4074415158563Nonecode258Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switches Item No 2.2.4 & Page No 4Point710.85710.8528.0FalseNoneNoneFalseNoneFalse19903.80
4074416158563Nonecode259Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box Item No 2.2.5 & Page No 4Point1038.451038.459.0FalseNoneNoneFalseNoneFalse9346.050
4074417158563Nonecode260Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 1-2Way Item No 3.4.1 & Page No 7Each144.9144.910.0FalseNoneNoneFalseNoneFalse1449.00
4074418158563Nonecode261Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way Item No 3.4.2 & Page No 7Each166.95166.9539.0FalseNoneNoneFalseNoneFalse6511.050
4074419158563Nonecode262Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Item No 3.4.3 & Page No 7Each185.85185.857.0FalseNoneNoneFalseNoneFalse1300.950
4074420158563Nonecode263Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Item No 3.4.4 & Page No 7Each231.0231.022.0FalseNoneNoneFalseNoneFalse5082.00
4074421158563Nonecode264Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Item No 3.4.5 & Page No 7Each274.05274.05317.0FalseNoneNoneFalseNoneFalse86873.850
4074422158563Nonecode265Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Item No 3.4.6 & Page No 7Each334.95334.9563.0FalseNoneNoneFalseNoneFalse21101.850
4074423158563Nonecode266Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16Way Item No 3.4.7 & Page No 7Each381.15381.154.0FalseNoneNoneFalseNoneFalse1524.60
4074424158563Nonecode267Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18Way Item No 3.4.8 & Page No 7Each425.25425.258.0FalseNoneNoneFalseNoneFalse3402.00
4074425158563Nonecode268Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..1-2Module Item No 3.5.1 & Page No 7Each143.85143.8510.0FalseNoneNoneFalseNoneFalse1438.50
4074426158563Nonecode269Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2Module Item No 3.5.2 & Page No 7Each169.05169.0539.0FalseNoneNoneFalseNoneFalse6592.950
4074427158563Nonecode270Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module Item No 3.5.3 & Page No 7Each183.75183.757.0FalseNoneNoneFalseNoneFalse1286.250
4074428158563Nonecode271Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module Item No 3.5.4 & Page No 7Each245.7245.722.0FalseNoneNoneFalseNoneFalse5405.40
4074429158563Nonecode272Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Module Item No 3.5.5 & Page No 7Each298.2298.2317.0FalseNoneNoneFalseNoneFalse94529.40
4074430158563Nonecode273Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module Item No 3.5.6 & Page No 7Each361.2361.263.0FalseNoneNoneFalseNoneFalse22755.60
4074431158563Nonecode274Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16Module Item No 3.5.7 & Page No 7Each416.85416.854.0FalseNoneNoneFalseNoneFalse1667.40
4074432158563Nonecode275Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18Module Item No 3.5.8 & Page No 7Each479.85479.858.0FalseNoneNoneFalseNoneFalse3838.80
4074433158563Nonecode276Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -6Amps one Way Item No 3.6.1 & Page No 8Each107.1107.11438.0FalseNoneNoneFalseNoneFalse154009.80
4074434158563Nonecode277Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch Item No 3.6.2 & Page No 8Each174.3174.322.0FalseNoneNoneFalseNoneFalse3834.60
4074435158563Nonecode278Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket Item No 3.6.3 & Page No 8Each179.55179.55738.0FalseNoneNoneFalseNoneFalse132507.90
4074436158563Nonecode279Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Steeped fan Regulator Item No 3.6.4 & Page No 8Each374.85374.85130.0FalseNoneNoneFalseNoneFalse48730.50
4074437158563Nonecode280Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch Item No 3.6.7 & Page No 8Each189.0189.024.0FalseNoneNoneFalseNoneFalse4536.00
4074438158563Nonecode281Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Bell push Item No 3.6.8 & Page No 8Each185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
4074439158563Nonecode282Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch Item No 3.6.9 & Page No 8Each342.3342.34.0FalseNoneNoneFalseNoneFalse1369.20
4074440158563Nonecode283Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket Item No 3.6.10 & Page No 8Each247.8247.828.0FalseNoneNoneFalseNoneFalse6938.40
4074441158563Nonecode284Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone socket Item No 3.6.11 & Page No 8Each163.8163.87.0FalseNoneNoneFalseNoneFalse1146.60
4074442158563Nonecode285Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ 45/IO Outlet CAT - 6 Item No 3.6.12 & Page No 8Each353.85353.8514.0FalseNoneNoneFalseNoneFalse4953.90
4074443158563Nonecode286Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong bell Item No 12.2.1 & Page No 47Each258.3258.31.0FalseNoneNoneFalseNoneFalse258.30
4074444158563Nonecode287Supplying And Fixing Metal Fan Box with Round Hook. Item No 1.13 & Page No 3Each122.85122.85130.0FalseNoneNoneFalseNoneFalse15970.50
4074445158563Nonecode288Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary : 19mm dia 2mm thick Item No 1.2.1 & Page No 1Mtr69.369.31400.0FalseNoneNoneFalseNoneFalse97020.00
4074446158563Nonecode289Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary : 25mm dia 2mm thick Item No 1.2.2 & Page No 1Mtr81.981.95260.0FalseNoneNoneFalseNoneFalse430794.00
4074447158563Nonecode290Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary :325mm dia 2.5mm thick Item No 1.2.3 & Page No 1Mtr108.15108.15330.0FalseNoneNoneFalseNoneFalse35689.50
4074448158563Nonecode291Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19mm dia 2mm thick Item No 1.3.1 & Page No 1Mtr71.471.4600.0FalseNoneNoneFalseNoneFalse42840.00
4074449158563Nonecode292Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25mm dia 2mm thick Item No 1.3.2 & Page No 1Mtr82.9582.952725.0FalseNoneNoneFalseNoneFalse226038.750
4074450158563Nonecode293Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick Item No 1.3.3 & Page No 1Mtr103.95103.95140.0FalseNoneNoneFalseNoneFalse14553.00
4074451158563Nonecode294CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm Item No 2.3.2 & Page No 4Mtr27.327.35985.0FalseNoneNoneFalseNoneFalse163390.50
4074452158563Nonecode295CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm Item No 2.3.3 & Page No 4Mtr44.144.14610.0FalseNoneNoneFalseNoneFalse203301.00
4074453158563Nonecode296CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm Item No 2.3.4 & Page No 4Mtr66.1566.151450.0FalseNoneNoneFalseNoneFalse95917.50
4074454158563Nonecode297CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6sqmm Item No 2.3.5 & Page No 4Mtr96.696.6420.0FalseNoneNoneFalseNoneFalse40572.00
4074455158563Nonecode298CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10sqmm Item No 2.3.6 & Page No 4Mtr175.35175.351235.0FalseNoneNoneFalseNoneFalse216557.250
4074456158563Nonecode299CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16sqmm Item No 2.3.7 & Page No 5Mtr333.9333.930.0FalseNoneNoneFalseNoneFalse10017.00
4074457158563Nonecode300Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Single Door : 16way SP &N Item No 5.19.5 & Page No 17Each3078.63078.62.0FalseNoneNoneFalseNoneFalse6157.20
4074458158563Nonecode301Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door : 6way TP &N Item No 5.19.12 & Page No 17Each5187.05187.01.0FalseNoneNoneFalseNoneFalse5187.00
4074459158563Nonecode302Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door : Double Door : 8way TP &N Item No 5.19.13 & Page No 17Each6395.556395.555.0FalseNoneNoneFalseNoneFalse31977.750
4074460158563Nonecode303Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. 5-32A SP MCB Item No 5.18.1 & Page No 16Each435.75435.75108.0FalseNoneNoneFalseNoneFalse47061.00
4074461158563Nonecode304Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32A DP MCB Item No 5.18.4 & Page No 16Each775.95775.952.0FalseNoneNoneFalseNoneFalse1551.90
4074462158563Nonecode305Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40A TPN MCB Item No 5.18.8 & Page No 16Each3196.23196.21.0FalseNoneNoneFalseNoneFalse3196.20
4074463158563Nonecode306Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2pole Item No 5.20.4 & Page No 17Each4828.954828.951.0FalseNoneNoneFalseNoneFalse4828.950
4074464158563Nonecode307Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 4 pole Item No 5.20.8 & Page No 17Each5404.355404.351.0FalseNoneNoneFalseNoneFalse5404.350
4074465158563Nonecode308Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole Item No 5.20.10 & Page No 17Each5822.255822.256.0FalseNoneNoneFalseNoneFalse34933.50
4074466158563Nonecode309LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10W Item No 11.3.1 & Page No 42Each578.55578.55317.0FalseNoneNoneFalseNoneFalse183400.350
4074467158563Nonecode310LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 20/22W Item No 11.3.2 & Page No 42Each724.5724.5110.0FalseNoneNoneFalseNoneFalse79695.00
4074468158563Nonecode311LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 36/40W Item No 11.3.3 & Page No 42Each1332.451332.455.0FalseNoneNoneFalseNoneFalse6662.250
4074469158563Nonecode312Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Item No 12.46 & Page No 51Each66.1566.1561.0FalseNoneNoneFalseNoneFalse4035.150
4074470158563Nonecode313Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K Item No 11.11.5 & Page No 46Each282.45282.4561.0FalseNoneNoneFalseNoneFalse17229.450
4074471158563Nonecode314Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W Item No 11.5.3 & Page No 43Each1390.21390.2106.0FalseNoneNoneFalseNoneFalse147361.20
4074472158563Nonecode315Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. Item No 11.15 & Page No 46Each884.1884.17.0FalseNoneNoneFalseNoneFalse6188.70
4074473158563Nonecode316Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Item No 6.1 & Page No 29Each1566.61566.62.0FalseNoneNoneFalseNoneFalse3133.20
4074474158563Nonecode317Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm) Item No 6.2.2 & Page No 29Each4668.34668.320.0FalseNoneNoneFalseNoneFalse93366.00
4074475158563Nonecode318Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Item No 6.3.1 & Page No 29Each3133.23133.2130.0FalseNoneNoneFalseNoneFalse407316.00
4074476158563Nonecode319Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70W Item No 11.8.3 & Page No 45Each6291.66291.69.0FalseNoneNoneFalseNoneFalse56624.40
4074477158563Nonecode320Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. : On wall/ceiling/Rafters/Girders Item No 13.7.1 & Page No 55Each128.1128.1606.0FalseNoneNoneFalseNoneFalse77628.60
4074478158563Nonecode321Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Item No 13.10 & Page No 56Each179.55179.55130.0FalseNoneNoneFalseNoneFalse23341.50
4074479158563Nonecode322Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame Item No 13.13 & Page No 56Each742.35742.3522.0FalseNoneNoneFalseNoneFalse16331.70
4074480158563Nonecode323Supplying and Fixing 50mm class A GI pipe up to 4.5 Mtrs. long with a reducing collar of 50x40mm to which, an extension of 250 mm pipe is fixed for 125 or 250/400 watts MV / sodium vapour street light fitting, using suitable clamps, bolts ,nuts, and wiring using suitable capacity wires. Item No 13.3 & Page No 55Each5724.65724.69.0FalseNoneNoneFalseNoneFalse51521.40
4074481158563Nonecode324Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Item No 13.5 & Page No 55Each170.1170.19.0FalseNoneNoneFalseNoneFalse1530.90
4074482158563Nonecode325Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 10L Item No 7.1.1 & Page No 33Each7942.27942.21.0FalseNoneNoneFalseNoneFalse7942.20
4074483158563Nonecode326Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. upto 30 Litres Item No 13.15.1 & Page No 56Each697.2697.21.0FalseNoneNoneFalseNoneFalse697.20
4074484158563Nonecode327Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. Item No 8.3 & Page No 35Mtr46.246.2150.0FalseNoneNoneFalseNoneFalse6930.00
4074485158563Nonecode328Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair Item No 8.2.2 & Page No 35Mtr22.0522.05150.0FalseNoneNoneFalseNoneFalse3307.50
4074486158563Nonecode329Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 20Pair Item No 8.2.7 & Page No 35Mtr157.5157.550.0FalseNoneNoneFalseNoneFalse7875.00
4074487158563Nonecode330Supplying and drawing UTP-CAT 6E LAN cable. Item No 8.1 & Page No 35Mtr39.939.9425.0FalseNoneNoneFalseNoneFalse16957.50
4074488158563Nonecode331Supplying & fixing of I/O socket with back box Single I/o Item No 8.10.1 & Page No 35Each514.5514.514.0FalseNoneNoneFalseNoneFalse7203.00
4074489158563Nonecode332Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Item No 8.12.5 & Page No 36Each8295.08295.01.0FalseNoneNoneFalseNoneFalse8295.00
4074490158563Nonecode333Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Item No 8.9.2 & Page No 35Each43522.543522.51.0FalseNoneNoneFalseNoneFalse43522.50
4074491158563Nonecode334Supplying & Fixing of switch mounting rack with power manager & Cable manager. 9U with 450mm depth Item No 8.4.3 & Page No 35Each8899.88899.81.0FalseNoneNoneFalseNoneFalse8899.80
4074492158563Nonecode335Supplying & Fixing of …Mtrs Cat 6 Patch Cable 1mtr Item No 8.11.1 & Page No 36Each235.2235.22.0FalseNoneNoneFalseNoneFalse470.40
4074493158563Nonecode336Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr Item No 8.11.2 & Page No 36Each269.85269.8512.0FalseNoneNoneFalseNoneFalse3238.20
4074494158563Nonecode337Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair Item No 8.13.2 & Page No 36Each402.15402.151.0FalseNoneNoneFalseNoneFalse402.150
4074495158563Nonecode338Supplying, Installation, testing and commissioning of IP Dome Camera of 1/2.8*2Mega pixel Progressive CMOS, 1902x1080(2MP), 2.7mm to 13.5mm, F1.4, Motorized, with a min illumination of 0.05lux / F1.4 (colour,301RE) 0Lux/F1.4(IRon), 30M IR Distance, BLC/HLC/WDR(120db), min 2streams, compression should be H.265/H / MPEG, 128GB SD card, ONVIF Profiles, profile G&Q, POE camera, oprating temparature of 60 degrees. All the cameras should have CE,FCC,UL, IP66, IK10. The prices should include the necessary mounts and brackets. - MREach21210.021210.010.0FalseNoneNoneFalseNoneFalse212100.00
4074496158563Nonecode339Supplying, Installation, testing and commissioning of IP Bullet Camera of 1/2.8*2Mega pixel Progressive CMOS, 1902x1080(2MP), 2.7mm to 13.5mm, F1.4, Motorized, with a min illumination of 0.05lux / F1.4 (colour,301RE) 0Lux/F1.4(IRon), 60M IR Distance, BLC/HLC/WDR(120db), min 2streams, compression should be H.265/H / MPEG, 128GB SD card, ONVIF Profiles, profile G&Q, POE camera, oprating temparature of 60 degrees. All the cameras should have CE,FCC,UL, IP66, IK10. The prices should include the necessary mounts and brackets. - MREach22785.022785.09.0FalseNoneNoneFalseNoneFalse205065.00
4074497158563Nonecode340Supplying, Installation, testing and commissioning of 4TB Survivelance Hard Disk The rate shall include all mounting accessories complete as required. - MREach15225.015225.01.0FalseNoneNoneFalseNoneFalse15225.00
4074498158563Nonecode341Supplying, Installation, testing and commissioning of Quad face plate Camera side with IOS. The rate shall include all mounting accessories complete as required. - MREach299.25299.2520.0FalseNoneNoneFalseNoneFalse5985.00
4074499158563Nonecode342Supplying, Installation, testing and commissioning of 43" LED Monitor. The rate shall include all mounting accessories complete as required. - MREach63000.063000.01.0FalseNoneNoneFalseNoneFalse63000.00
4074500158563Nonecode343Supplying and drawing UTP-CAT 6E LAN cable. Item No 8.1 & Page No 35Mtr39.939.9925.0FalseNoneNoneFalseNoneFalse36907.50
4074501158563Nonecode344Supplying & fixing of I/O socket with back box Single I/o Item No 8.10.1 & Page No 35Each514.5514.520.0FalseNoneNoneFalseNoneFalse10290.00
4074502158563Nonecode345Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Item No 8.12.5 & Page No 36Each8295.08295.01.0FalseNoneNoneFalseNoneFalse8295.00
4074503158563Nonecode346Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Item No 8.9.2 & Page No 35Each43522.543522.51.0FalseNoneNoneFalseNoneFalse43522.50
4074504158563Nonecode347Supplying & Fixing of …Mtrs Cat 6 Patch Cable 1mtr Item No 8.11.1 & Page No 36Each235.2235.210.0FalseNoneNoneFalseNoneFalse2352.00
4074505158563Nonecode348Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr Item No 8.11.2 & Page No 36Each269.85269.8520.0FalseNoneNoneFalseNoneFalse5397.00
4074506158563Nonecode349Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 250Amps 4Pole 36kA Item No 5.15.15 & Page No 16Each24722.2524722.251.0FalseNoneNoneFalseNoneFalse24722.250
4074507158563Nonecode350Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Item No 5.21 & Page No 17Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
4074508158563Nonecode351Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Item No 5.33 & Page No 18Each9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
4074509158563Nonecode352Supplying, fixing and wiring Electronic Trivector Meter (ETV)5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. Item No 5.35 & Page No 18Each5990.255990.251.0FalseNoneNoneFalseNoneFalse5990.250
4074510158563Nonecode353Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. Item No 5.34 & Page No 18Each590.1590.16.0FalseNoneNoneFalseNoneFalse3540.60
4074511158563Nonecode354Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. Item No 5.38 & Page No 18Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
4074512158563Nonecode355Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminium Strips Item No 5.40.2 & Page No 19Mtr3606.753606.758.0FalseNoneNoneFalseNoneFalse28854.00
4074513158563Nonecode356Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100Amps 4Pole 25kA Item No 5.15.9 & Page No 16Each8911.358911.3512.0FalseNoneNoneFalseNoneFalse106936.20
4074514158563Nonecode357Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm Item No 5.41.3 & Page No 19Mtr582.75582.7548.0FalseNoneNoneFalseNoneFalse27972.00
4074515158563Nonecode358Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG Item No 5.42.1 & Page No 19Sq CM0.530.53167800.0FalseNoneNoneFalseNoneFalse88934.00
4074516158563Nonecode359Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG Item No 5.42.2 & Page No 19Sq CM0.450.4544000.0FalseNoneNoneFalseNoneFalse19800.00
4074517158563Nonecode360Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. Item No 3.9 & Page No 8Sq CM0.370.37118800.0FalseNoneNoneFalseNoneFalse43956.00
4074518158563Nonecode361Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 10ft copper bonded rod with backfill compound Item No 12.60.3 & Page No 54Each8918.78918.72.0FalseNoneNoneFalseNoneFalse17837.40
4074519158563Nonecode362Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 6ft copper bonded rod with backfill compound Item No 12.60.2 & Page No 54Each6541.56541.52.0FalseNoneNoneFalseNoneFalse13083.00
4074520158563Nonecode363Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip Item No 12.58.2 & Page No 53Mtr86.186.140.0FalseNoneNoneFalseNoneFalse3444.00
4074521158563Nonecode364Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 : 4Core 10Sqmm cable Item No 32.03, SL NO 199 ESCOM SR 23-24Mtr123.9123.950.0FalseNoneNoneFalseNoneFalse6195.00
4074522158563Nonecode365Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 : 3.5Core 300Sqmm Item No 32.19, SL NO 215 ESCOM SR 23-24Mtr1119.311119.31225.0FalseNoneNoneFalseNoneFalse251844.750
4074523158563Nonecode366Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct : 2.5 sqmm to 25 sqmm Item No 21.05 SL NO 174 ESCOM SR 23-24Mtr21.9321.9350.0FalseNoneNoneFalseNoneFalse1096.50
4074524158563Nonecode367Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct : 300sqmm to 400Sqmm Item No 21.08 SL NO 177 ESCOM SR 23-24Mtr35.8835.88225.0FalseNoneNoneFalseNoneFalse8073.00
4074525158563Nonecode368Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KVclass (metal only) 25mm dia Item No 63.01 SL NO 507 ESCOM SR 23-24Each82.9582.952.0FalseNoneNoneFalseNoneFalse165.90
4074526158563Nonecode369Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KVclass (metal only) 45mm dia Item No 63.04 SL NO 510 ESCOM SR 23-24Each206.85206.852.0FalseNoneNoneFalseNoneFalse413.70
4074527158563Nonecode370Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10Sqmm Long Barrel Item No 60.01 SL NO 469 ESCOM SR 23-24Each2.12.18.0FalseNoneNoneFalseNoneFalse16.80
4074528158563Nonecode371Heavy Duty Copper Terminal Long Barrel 150 Sqmm Copper Terminal, Apprx Wt: 98 Gm Item No 59.07 SL NO 463 ESCOM SR 23-24Each192.15192.152.0FalseNoneNoneFalseNoneFalse384.30
4074529158563Nonecode372Heavy Duty Copper Terminal Long Barrel 300 Sqmm Copper Terminal Item No 59.11 SL NO 467 ESCOM SR 23-24Each540.75540.756.0FalseNoneNoneFalseNoneFalse3244.50
4074530158563Nonecode373Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washers or welding as required. 300x50mm Item No 12.59.2 & Page No 54Mtr616.35616.355.0FalseNoneNoneFalseNoneFalse3081.750
4074531158563Nonecode374Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (UNI-SR V-1, Item No - 1.14.1 )Cum107.1107.174.83FalseNoneNoneFalseNoneFalse8014.2930
4074532158563Nonecode375Providing and laying in position plain cement concrete for levelling course Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (UNI-SR V-1, Item No - 2.1.2 )Cum5947.25947.24.86FalseNoneNoneFalseNoneFalse28903.3920
4074533158563Nonecode376Providing and laying in position Reinforced cement concrete Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (UNI-SR V-1, Item No - 2.2.2.1 ) : Base Slab (including formwork cost at 8%)Cum7759.967759.9612.74FalseNoneNoneFalseNoneFalse98861.89040
4074534158563Nonecode377Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) : side wall inclusive of formwork at 10%Cum7484.47484.48.18FalseNoneNoneFalseNoneFalse61222.3920
4074535158563Nonecode378Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) : Top covering slab inclusive of formwork at 50%Cum10206.010206.05.25FalseNoneNoneFalseNoneFalse53581.50
4074536158563Nonecode379Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (UNI-SR V-1, Item No - 1.9 )Cum279.3279.316.56FalseNoneNoneFalseNoneFalse4625.2080
4074537158563Nonecode380Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.853.4FalseNoneNoneFalseNoneFalse319361.490
4074538158563Nonecode381Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400% and having solid content of above 90% @ 1.6kg per Sqm in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g/ Sqm. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (UNI-SR V-3, Item No - 9.3 )Sqm932.4932.472.0FalseNoneNoneFalseNoneFalse67132.80
4074539158563Nonecode382Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm (Comn-SR V-5, Item No -11.2, Page No-111)Mtr5041.055041.051.5FalseNoneNoneFalseNoneFalse7561.5750
4074540158563Nonecode383Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (Comn-SR V-5, Item No -13, Page No-111)Each2247.02247.01.0FalseNoneNoneFalseNoneFalse2247.00
4074541158563Nonecode384Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 1.00 HP/0.75KW - 7 STG ( WS & UGD Comm SR V-5, Chapter-15, Item No - 6.1 )Nos13983.913983.91.0FalseNoneNoneFalseNoneFalse13983.90
4074542158563Nonecode385Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.(P.No.140, I.No 12.4 , Vol 5 of PW,P & IWTD S.R 2022-23)Nos5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
4074543158563Nonecode386Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 0.00 to 50.00 mtrs 1.1 O010AMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
4074544158563Nonecode387Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 50.00 to 100.00 mtrs 1.2 O010BMtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
4074545158563Nonecode388Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 100.00 to 150.00 mtrs 1.3 O010CMtr517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
4074546158563Nonecode389Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 150.00 to 200.00 mtrs 1.4 O010DMtr600.6600.650.0FalseNoneNoneFalseNoneFalse30030.00
4074547158563Nonecode390Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 200.00 to 250.00 mtrs 1.5 O010EMtr704.55704.5550.0FalseNoneNoneFalseNoneFalse35227.50
4074548158563Nonecode391Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 250.00 to 260.00 mtrs 1.6 O010FMtr777.0777.010.0FalseNoneNoneFalseNoneFalse7770.00
4074549158563Nonecode392Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socketconforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (P.No.143, I.No 12.32. Vol 5 of PW,P & IWTD S.R 2022-23)Mtr2029.652029.6530.0FalseNoneNoneFalseNoneFalse60889.50
4074550158563Nonecode393Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)Nos172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
4074551158563Nonecode394Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)Nos157.5157.55.0FalseNoneNoneFalseNoneFalse787.50
4074552158563Nonecode395Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For -For -7.5 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00”. (Page No. : 152, Item No.13.15.7 KWS & DB S R Vol-5 2022-23)Each42850.542850.51.0FalseNoneNoneFalseNoneFalse42850.50
4074553158563Nonecode396Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1X3X6 Sqm. (Page No. : 154, Item No.13.22.4, KWS & DB S R Vol-5 2022-23)Mtr194.25194.25230.0FalseNoneNoneFalseNoneFalse44677.50
4074554158563Nonecode397Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Page No. : 156, Item No.13.32 KWS & DB S R Vol-5 2022-23)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
4074555158563Nonecode398Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. 50 mm dia (PWD SR 2022-23 , vol-2, P119, I no 13.10.6)Mtr723.45723.452.0FalseNoneNoneFalseNoneFalse1446.90
4074556158563Nonecode399Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps. (Page No. : 155, Item No.13.23.2 , KWS & DB S R Vol-5 2022-23)Each16695.016695.02.0FalseNoneNoneFalseNoneFalse33390.00
4074557158563Nonecode400Erection of single phase preventer / ammeters / including fixing selector switch / voltmeter / current operated earth leakage circuit breakers / voltage operated circuit breaker / above 100A fuse channel set (3 Nos) HRC fuses above 100A (3 Nos.) / Digital ammeter/digital volt meter/set of 3 indicating lamps /MCB / Relays /A-V selector switches including wiring using suitable capacity wires, bolts, nuts,screws. (PWD Ele SR 2022-23 Pg no.46 Sl no.13.16)Nos207.9207.91.0FalseNoneNoneFalseNoneFalse207.90
4074558158563Nonecode401Fabricating, supplying and mounting MS box made out of 18 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation provided with hinged front cover with with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 Tanks Treatment wit powder coat ed paint & finaly finished with approved colour & etc. (PWD Ele SR 2-23-24 Pg no.20, Sl no.5.42.3)Sqm0.40.430000.0FalseNoneNoneFalseNoneFalse12000.00
4074559158563Nonecode402Supplying and fixing miniature circuit breakers/isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as required - 40 to 63 amps triple pole. ( PWD Ele SR 2-23-24 P-47, It No.6.16.2)Sqm710.85710.851.0FalseNoneNoneFalseNoneFalse710.850
4074560158563Nonecode403Supplying and running of GI copper strip or grounding connection using necessary fixing material required 600x600x3mm GI plate. (PWD Ele SR 2-23-24 (P-54, Sl no.12.58.6)Sqm918.75918.751.0FalseNoneNoneFalseNoneFalse918.750
4074561158563Nonecode404Supplying and fixing Porcelain fuse channel with cut out on the existing wooden /panel using necessary nuts bolts and washer etc., complete. 16 A. (P-No.10 , I.No.5.7.1 KPWD Ele SR 2022-23),Sqm164.85164.853.0FalseNoneNoneFalseNoneFalse494.550
4074562158563Nonecode405Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. (P.No.115, I.No.13.4.4 of KPWD Elec S.R 2022-23)Nos897.75897.751.0FalseNoneNoneFalseNoneFalse897.750
4074563158563Nonecode4061.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 , 4 core 16sqmm. ( Ele SR 22-23 Pg no. sl no. 32.05)Mtr148.93148.9330.0FalseNoneNoneFalseNoneFalse4467.90
4074564158563Nonecode407Labour charges for Laying of 1.1 KV Class UG cable 6 Sqmm to 16 sqmmMtr12.4712.4730.0FalseNoneNoneFalseNoneFalse374.10
4074565158563Nonecode408Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating in Hard soil etc., complete. complete as per specifications and direction of the Engineer-in-Charge. (As per Civil SR KSRB I-1.17.1, P-10, vol -1)Mtr203.7203.730.0FalseNoneNoneFalseNoneFalse6111.00
4074566158563Nonecode409Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 65mm dia. Vol-5 SR(2021-22), P-142, I- 11.2.7Mtr754.95754.9530.0FalseNoneNoneFalseNoneFalse22648.50
4074567158563Nonecode410Supplying and fixing LT cast iron pot heads suitable for 1.1 KV class UG cable filled wiith necessary bitumen / insulating compound complete. With terminals, clamps, bolts nuts and washers etc.complete for 16 Sqmm as per specification. (KPWD Ele SR Pg no.62 sl no.7.13.2)Each283.5283.51.0FalseNoneNoneFalseNoneFalse283.50
4074568158563Nonecode411Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m. (P.No.6, I.No.1.6.1 of KPWD S.R 2022-23)Cum508.2508.274.25FalseNoneNoneFalseNoneFalse37733.850
4074569158563Nonecode412Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/Sqm: 63mm(weight of pipe -0.662 kg) (P.No.134, I.No.M010C of KPWD S.R 2022-23)Mtr145.95145.95165.0FalseNoneNoneFalseNoneFalse24081.750
4074570158563Nonecode413Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (P.No.7, I.No.1.10 of KPWD S.R 2022-23)Cum168.0168.055.69FalseNoneNoneFalseNoneFalse9355.920
4074571158563Nonecode414Design, supplying, erecting testing and commissioning of -passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,. (item No - 14.4.2 PWD Ele SR 2023-2024) D.With Out Machine Room-SS Finish ( 8-Passgenrs 5 - Stops )Each1672311.771672311.771.0FalseNoneNoneFalseNoneFalse1672311.770
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17272619310000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17272619310000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17272619310000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17272619310000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17272619310000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17272619330000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17272619370000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17272619420000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17272619450000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17272619490000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17272619520000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17272619570000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17272619620000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17272619660000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17272619690000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17272619720000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17272619750000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17272619780000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17272619830000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17272619880000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1727272050000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone