1726914880000 | 0 | None | None | Buildings | Construction of New Building of Deputy Deirector (Admin) Veterinary Hospital in Dharwad District. | 5854298.44 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4047894 | 157141 | None | 19.3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2571.56 | 2571.56 | 5.8 | False | None | None | False | None | False | 14915.048 | 0 | 4047895 | 157141 | None | 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 147.83 | False | None | None | False | None | False | 56345.4045 | 0 | 4047896 | 157141 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 147.83 | False | None | None | False | None | False | 41288.919 | 0 | 4047897 | 157141 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 6.08 | False | None | None | False | None | False | 38233.776 | 0 | 4047898 | 157141 | None | 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all othe appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 32.4 | False | None | None | False | None | False | 16125.48 | 0 | 4047899 | 157141 | None | 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6652.8 | 6652.8 | 25.52 | False | None | None | False | None | False | 169779.456 | 0 | 4047900 | 157141 | None | 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Centering form work. | Cum | 4656.96 | 4656.96 | 25.52 | False | None | None | False | None | False | 118845.6192 | 0 | 4047901 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, First Floor Columns, Lintel, Chejja, Roof Beam, Slab. | Cum | 7253.58 | 7253.58 | 83.78 | False | None | None | False | None | False | 607704.9324 | 0 | 4047902 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Second Floor Columns, roof beam,Slab. | Cum | 7322.01 | 7322.01 | 3.12 | False | None | None | False | None | False | 22844.6712 | 0 | 4047903 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centering form work First Floor Columns. | Cum | 5077.51 | 5077.51 | 10.14 | False | None | None | False | None | False | 51485.9514 | 0 | 4047904 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centering form work Second Floor Columns | Cum | 5125.41 | 5125.41 | 0.97 | False | None | None | False | None | False | 4971.6477 | 0 | 4047905 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges FF Lintels. | Cum | 4352.15 | 4352.15 | 5.76 | False | None | None | False | None | False | 25068.384 | 0 | 4047906 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges for Chejja. | Cum | 3264.11 | 3264.11 | 4.21 | False | None | None | False | None | False | 13741.9031 | 0 | 4047907 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges for Roof Beam. | Cum | 4352.15 | 4352.15 | 21.86 | False | None | None | False | None | False | 95137.999 | 0 | 4047908 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges for Sf Roof Beam. | Cum | 4393.21 | 4393.21 | 1.06 | False | None | None | False | None | False | 4656.8026 | 0 | 4047909 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges for FF slab. | Cum | 3626.79 | 3626.79 | 41.81 | False | None | None | False | None | False | 151636.0899 | 0 | 4047910 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116 for Centring charges for SF Slab. | Cum | 3661.01 | 3661.01 | 1.09 | False | None | None | False | None | False | 3990.5009 | 0 | 4047911 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116. Ground Floor Sump and Septic Tank Slab. | Cum | 7185.15 | 7185.15 | 6.08 | False | None | None | False | None | False | 43685.712 | 0 | 4047912 | 157141 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Extra Added for Centering & Shuttering Charges as per Appendix I S.No.12 PG No: 115,116. for Centering form work Ground Floor Sump and Septic Tank Slab | Cum | 3592.58 | 3592.58 | 6.08 | False | None | None | False | None | False | 21842.8864 | 0 | 4047913 | 157141 | None | 2.11h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification First Floor. | Kg | 94.82 | 94.82 | 12415.0 | False | None | None | False | None | False | 1177190.3 | 0 | 4047914 | 157141 | None | 2.11h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Second Floor. | Kg | 95.71 | 95.71 | 374.4 | False | None | None | False | None | False | 35833.824 | 0 | 4047915 | 157141 | None | 6.4 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9180.66 | 9180.66 | 84.65 | False | None | None | False | None | False | 777142.869 | 0 | 4047916 | 157141 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 6348.34 | 6348.34 | 3.53 | False | None | None | False | None | False | 22409.6402 | 0 | 4047917 | 157141 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 178.08 | 178.08 | 531.0 | False | None | None | False | None | False | 94560.48 | 0 | 4047918 | 157141 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 146358.44 | 146358.44 | 0.881 | False | None | None | False | None | False | 128941.78564 | 0 | 4047919 | 157141 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7890.64 | 7890.64 | 17.48 | False | None | None | False | None | False | 137928.3872 | 0 | 4047920 | 157141 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 270.3 | 270.3 | 278.75 | False | None | None | False | None | False | 75346.125 | 0 | 4047921 | 157141 | None | 15.12 | Newly Constructed Roof Podium with PU Waterproof coating Above 500 m2 Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof Podium area applied 2.4kg m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer 0.2L m2 and protection with 120gsm Geotextile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85 Tensile strength 2 Mpa as per ASTM D 412, Elongation at break greater 400Percent confirms to ASTM C 1305 for crack bridging ability no cracks up to 3.2mm Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN TS 14416. The finished cost to include surface preparation, making coving of 50 mm 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 1234.9 | 1234.9 | 23.22 | False | None | None | False | None | False | 28674.378 | 0 | 4047922 | 157141 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, .curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 3023.12 | 3023.12 | 212.79 | False | None | None | False | None | False | 643289.7048 | 0 | 4047923 | 157141 | None | 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1140.56 | 1140.56 | 87.8 | False | None | None | False | None | False | 100141.168 | 0 | 4047924 | 157141 | None | 12.90 | Providing fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made. | Sqm | 7138.04 | 7138.04 | 21.24 | False | None | None | False | None | False | 151611.9696 | 0 | 4047925 | 157141 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 337.08 | 337.08 | 6.6 | False | None | None | False | None | False | 2224.728 | 0 | 4047926 | 157141 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. | Sqm | 2507.96 | 2507.96 | 2.3 | False | None | None | False | None | False | 5768.308 | 0 | 4047927 | 157141 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.0 | 106.0 | 697.53 | False | None | None | False | None | False | 73938.18 | 0 | 4047928 | 157141 | None | 8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 56.18 | 56.18 | 1395.06 | False | None | None | False | None | False | 78374.4708 | 0 | 4047929 | 157141 | None | 8.35.2 | Painting with Silicon & Acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 209.88 | 209.88 | 697.53 | False | None | None | False | None | False | 146397.5964 | 0 | 4047930 | 157141 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 299.98 | 299.98 | 315.9 | False | None | None | False | None | False | 94763.682 | 0 | 4047931 | 157141 | None | 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 146.28 | 146.28 | 121.45 | False | None | None | False | None | False | 17765.706 | 0 | 4047932 | 157141 | None | 10.1.4 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:.PVC pipes 63mm dia., 6 kg/sqcm & class 3 | m | 170.66 | 170.66 | 72.0 | False | None | None | False | None | False | 12287.52 | 0 | 4047933 | 157141 | None | 10.1.4 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:.PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 655.08 | 655.08 | 36.0 | False | None | None | False | None | False | 23582.88 | 0 | 4047934 | 157141 | None | 13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. | m | 256.52 | 256.52 | 84.0 | False | None | None | False | None | False | 21547.68 | 0 | 4047935 | 157141 | None | 13.17.4 | Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 90 mm long, weighing not less than 93 g. | Nos | 256.52 | 256.52 | 4.0 | False | None | None | False | None | False | 1026.08 | 0 | 4047936 | 157141 | None | 14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 49.82 | 49.82 | 2.0 | False | None | None | False | None | False | 99.64 | 0 | 4047937 | 157141 | None | 14.3.2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid. | Each | 6153.3 | 6153.3 | 1.0 | False | None | None | False | None | False | 6153.3 | 0 | 4047938 | 157141 | None | 14.7A | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. | Each | 4368.26 | 4368.26 | 1.0 | False | None | None | False | None | False | 4368.26 | 0 | 4047939 | 157141 | None | 14.59B | Providing and fixing Single lever wall mixer made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium. | Each | 8533.0 | 8533.0 | 1.0 | False | None | None | False | None | False | 8533.0 | 0 | 4047940 | 157141 | None | 14.28.2.1 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia | No | 97.52 | 97.52 | 1.0 | False | None | None | False | None | False | 97.52 | 0 | 4047941 | 157141 | None | 13.11.1 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | No | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | 4047942 | 157141 | None | 13.34 | KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification | l | 9.54 | 9.54 | 2000.0 | False | None | None | False | None | False | 19080.0 | 0 | 4047943 | 157141 | None | 13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation | No | 5980.52 | 5980.52 | 4.0 | False | None | None | False | None | False | 23922.08 | 0 | 4047944 | 157141 | None | 1.1.1 | Open Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceilling ans RCC wall/stone structure or rawl plugs in case of bricks walls and cement plastering the damaged portation using heavy guage saddles at an intervak of 700mm using NF screws. | Mtr | 73.14 | 73.14 | 200.0 | False | None | None | False | None | False | 14628.0 | 0 | 4047945 | 157141 | None | 1.7.2 | Extra for groove cutting in brick wall/cc floor to the suitable depth for concealing of conduct/GI pipe and plastering finishing uo to wall surface complete uo to 50mm conduct cc floor. | Mtr | 73.14 | 73.14 | 200.0 | False | None | None | False | None | False | 14628.0 | 0 | 4047946 | 157141 | None | 2.1.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch. | Point | 302.1 | 302.1 | 40.0 | False | None | None | False | None | False | 12084.0 | 0 | 4047947 | 157141 | None | 2.1.2 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch. | Point | 417.64 | 417.64 | 40.0 | False | None | None | False | None | False | 16705.6 | 0 | 4047948 | 157141 | None | 3.1.1 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way. | Each | 135.68 | 135.68 | 50.0 | False | None | None | False | None | False | 6784.0 | 0 | 4047949 | 157141 | None | 3.7 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. | Each | 684.76 | 684.76 | 1.0 | False | None | None | False | None | False | 684.76 | 0 | 4047950 | 157141 | None | 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.12"x12"x3" (300 x 300 x 76 MM) | Each | 127.2 | 127.2 | 20.0 | False | None | None | False | None | False | 2544.0 | 0 | 4047951 | 157141 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments | Mtr | 27.56 | 27.56 | 480.0 | False | None | None | False | None | False | 13228.8 | 0 | 4047952 | 157141 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5sqmm | Mtr | 44.52 | 44.52 | 480.0 | False | None | None | False | None | False | 21369.6 | 0 | 4047953 | 157141 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm | Mtr | 66.78 | 66.78 | 640.0 | False | None | None | False | None | False | 42739.2 | 0 | 4047954 | 157141 | None | 3.8 | Supplying 4mm thick Plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F screws. | Sq CM | 0.43 | 0.43 | 14000.0 | False | None | None | False | None | False | 6020.0 | 0 | 4047955 | 157141 | None | 11.11.7 | Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5hould be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K | Each | 451.56 | 451.56 | 25.0 | False | None | None | False | None | False | 11289.0 | 0 | 4047956 | 157141 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 56" Sweep (1400mm) Regular model | Each | 3212.86 | 3212.86 | 5.0 | False | None | None | False | None | False | 16064.3 | 0 | 4047957 | 157141 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 255.46 | 255.46 | 418.78 | False | None | None | False | None | False | 106981.5388 | 0 | 4047958 | 157141 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 408.1 | 408.1 | 315.9 | False | None | None | False | None | False | 128918.79 | 0 |
|