1727332166000 | 0 | None | None | Water supply/sewage lines | Providing and laying UGD pipeline and construction of machineholes at RS naidu nagar near munnavar mosque, ward no.9, Mysuru | 1609926.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4079631 | 158779 | None | code01 | Cutting of Asphalt road surface for pipe line trenches and disposing off the excavated stuff as directed excluding barricading, danger lighting etc., in the following classification. | Cum | 935.55 | 935.55 | 40.0 | False | None | None | False | None | False | 37422.0 | 0 | 4079632 | 158779 | None | code02 | Cutting of Macadam road surface for pipe line trenches and disposing off the excavated stuff as directed excluding barricading, danger lighting etc., in the following classification. | Cum | 856.8 | 856.8 | 60.0 | False | None | None | False | None | False | 51408.0 | 0 | 4079633 | 158779 | None | code03 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, excluding setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the vailable excavated earth locally for the work etc., and all other appurtenances complete in the following strata.In all kinds of soils 0 to 1.5 M depth: | Cum | 275.1 | 275.1 | 557.51 | False | None | None | False | None | False | 153371.001 | 0 | 4079634 | 158779 | None | code04 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, excluding setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the vailable excavated earth locally for the work etc., and all other appurtenances complete in the following strata.In all kinds of soils 1.50 to 3.00 M depth: | Cum | 347.55 | 347.55 | 85.07 | False | None | None | False | None | False | 29566.0785 | 0 | 4079635 | 158779 | None | code05 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, excluding setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the vailable excavated earth locally for the work etc., and all other appurtenances complete in the following strata. Ordinary/soft rock (without requiring blasting) 0 to 1.5 M depth: | Cum | 476.7 | 476.7 | 139.38 | False | None | None | False | None | False | 66442.446 | 0 | 4079636 | 158779 | None | code06 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, excluding setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the vailable excavated earth locally for the work etc., and all other appurtenances complete in the following strata. Ordinary/soft rock (without requiring blasting) 1.5 to 3.0 M depth: | Cum | 584.85 | 584.85 | 26.18 | False | None | None | False | None | False | 15311.373 | 0 | 4079637 | 158779 | None | code07 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, excluding setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the vailable excavated earth locally for the work etc., and all other appurtenances complete in the following strata. In Hard rock (requiring blasting) 1.5 to 3.0 M depth: | Cum | 789.6 | 789.6 | 19.63 | False | None | None | False | None | False | 15499.848 | 0 | 4079638 | 158779 | None | code08 | Providing lowering laying, jointing, testing and commissioning of following diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary survey works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with Rubber ring gasket joints200mm dia SW pipe | Rmtr | 772.8 | 772.8 | 500.0 | False | None | None | False | None | False | 386400.0 | 0 | 4079639 | 158779 | None | code09 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, excluding loading unloading at both destinations and cuts of pipes wherever necessary excluding jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift excluding encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or elected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Rmtr | 431.55 | 431.55 | 88.0 | False | None | None | False | None | False | 37976.4 | 0 | 4079640 | 158779 | None | code10 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover) 1.00 M.depth | No | 26248.95 | 26248.95 | 2.0 | False | None | None | False | None | False | 52497.9 | 0 | 4079641 | 158779 | None | code11 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.20M.depth | No | 30891.42 | 30891.42 | 3.0 | False | None | None | False | None | False | 92674.26 | 0 | 4079642 | 158779 | None | code12 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.30M.depth | No | 33212.66 | 33212.66 | 3.0 | False | None | None | False | None | False | 99637.98 | 0 | 4079643 | 158779 | None | code13 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.40M.depth | No | 35533.89 | 35533.89 | 4.0 | False | None | None | False | None | False | 142135.56 | 0 | 4079644 | 158779 | None | code14 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.50M.depth | No | 37855.13 | 37855.13 | 2.0 | False | None | None | False | None | False | 75710.26 | 0 | 4079645 | 158779 | None | code15 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.60M.depth | No | 40176.36 | 40176.36 | 3.0 | False | None | None | False | None | False | 120529.08 | 0 | 4079646 | 158779 | None | code16 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover)1.80M.depth | No | 44818.83 | 44818.83 | 1.0 | False | None | None | False | None | False | 44818.83 | 0 | 4079647 | 158779 | None | code17 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size excluding supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, uring,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. For 1.2m dia (Including Manhole Frame and cover) 2.00M.depth | No | 49461.3 | 49461.3 | 1.0 | False | None | None | False | None | False | 49461.3 | 0 | 4079648 | 158779 | None | code18 | Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation excluding watering, consolidation in layers of 15 cms., thickness excluding disposing off the surplus earth with all lead and lift. | Cum | 168.0 | 168.0 | 827.76 | False | None | None | False | None | False | 139063.68 | 0 |
|