tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727326685000 | 0 | None | None | Buildings | Construction of building to Anganawadi centre no.13 at Ghanti Plot in Hidkal Village at Raibag Taluka Belagavi Dist.(MGNREGA and CONVERGENCY FUND) | 801806.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4077890 | 158704 | None | code01 | Supplying fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (The laps and wastages shall not be measured separately) etc complete as per direction of the Engineer incharge of the work. | Tonne | 93929.85 | 93929.85 | 1.96 | False | None | None | False | None | False | 184102.506 | 0 | 4077891 | 158704 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately etc complete as per direction of the Engineer incharge of the work. | Cum | 6527.85 | 6527.85 | 5.94 | False | None | None | False | None | False | 38775.429 | 0 | 4077892 | 158704 | None | code03 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 309.75 | 309.75 | 215.16 | False | None | None | False | None | False | 66645.81 | 0 | 4077893 | 158704 | None | code04 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 389.55 | 389.55 | 190.4 | False | None | None | False | None | False | 74170.32 | 0 | 4077894 | 158704 | None | code05 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Sqm | 105.0 | 105.0 | 215.16 | False | None | None | False | None | False | 22591.8 | 0 | 4077895 | 158704 | None | code06 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). | Sqm | 1299.9 | 1299.9 | 45.48 | False | None | None | False | None | False | 59119.452 | 0 | 4077896 | 158704 | None | code07 | Providing and fxing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/m2 including pointing with white cement mixed with pigment of matching shade, all complete as approved etc complete as per direction of the Engineer incharge of the work. | m | 142.8 | 142.8 | 44.2 | False | None | None | False | None | False | 6311.76 | 0 | 4077897 | 158704 | None | code08 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1732.5 | 1732.5 | 8.1 | False | None | None | False | None | False | 14033.25 | 0 | 4077898 | 158704 | None | code09 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2994.6 | 2994.6 | 23.12 | False | None | None | False | None | False | 69235.152 | 0 | 4077899 | 158704 | None | code10 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.etc complete as per direction of the Engineer incharge of the work. | Sqm | 1521.45 | 1521.45 | 23.6 | False | None | None | False | None | False | 35906.22 | 0 | 4077900 | 158704 | None | code11 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 196.56 | False | None | None | False | None | False | 37769.004 | 0 | 4077901 | 158704 | None | code12 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor TP shall not be made) | Sqm | 5274.15 | 5274.15 | 9.36 | False | None | None | False | None | False | 49366.044 | 0 | 4077902 | 158704 | None | code13 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete etc complete as per direction of the Engineer incharge of the work. | Sqm | 843.15 | 843.15 | 11.24 | False | None | None | False | None | False | 9477.006 | 0 | 4077903 | 158704 | None | code14 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged etc complete as per direction of the Engineer incharge of the work. | Kg | 593.25 | 593.25 | 15.53 | False | None | None | False | None | False | 9213.1725 | 0 | 4077904 | 158704 | None | code15 | Providing Sal wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Cum | 101862.6 | 101862.6 | 0.361 | False | None | None | False | None | False | 36772.3986 | 0 | 4077905 | 158704 | None | code16 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 3.0 | False | None | None | False | None | False | 3200.4 | 0 | 4077906 | 158704 | None | code17 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. etc complete as per direction of the Engineer incharge of the work. | Sqm | 7816.2 | 7816.2 | 6.93 | False | None | None | False | None | False | 54166.266 | 0 | 4077907 | 158704 | None | code18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 143.85 | 143.85 | 215.16 | False | None | None | False | None | False | 30950.766 | 0 |
| 1727326685000 | 0 | None | None | Buildings | 15th Finance | 166368.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4077908 | 158705 | None | code01 | Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification etc complete as per direction of the Engineer incharge of the work. | m | 333.9 | 333.9 | 11.7 | False | None | None | False | None | False | 3906.63 | 0 | 4077909 | 158705 | None | code02 | Providing and fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. etc complete as per direction of the Engineer incharge of the work. | Sqm | 1667.4 | 1667.4 | 3.47 | False | None | None | False | None | False | 5785.878 | 0 | 4077910 | 158705 | None | code03 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 297.15 | 297.15 | 190.4 | False | None | None | False | None | False | 56577.36 | 0 | 4077911 | 158705 | None | code04 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 144.9 | 144.9 | 52.96 | False | None | None | False | None | False | 7673.904 | 0 | 4077912 | 158705 | None | code05 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per pecifications etc complete as per direction of the Engineer incharge of the work. | cm | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 | 4077913 | 158705 | None | code06 | Providing and placing on terrace(at floor levels) polyethylene water storage tank, IS:12701 marked, with over and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank etc complete as per direction of the Engineer incharge of the work. | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 4077914 | 158705 | None | code07 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required etc complete as per direction of the Engineer incharge of the work. | Nos | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 4077915 | 158705 | None | code08 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap etc complete as per direction of the Engineer incharge of the work. | Nos | 2462.25 | 2462.25 | 1.0 | False | None | None | False | None | False | 2462.25 | 0 | 4077916 | 158705 | None | code09 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete etc complete as per direction of the Engineer incharge of the work. | m | 296.1 | 296.1 | 20.0 | False | None | None | False | None | False | 5922.0 | 0 | 4077917 | 158705 | None | code10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction etc complete as per direction of the Engineer incharge of the work. | m | 254.1 | 254.1 | 30.0 | False | None | None | False | None | False | 7623.0 | 0 | 4077918 | 158705 | None | code11 | Providing and fixing on wall surface 2.5 kg / sq.cm H.D.P.E. rain down water pipes 110 mm outer dia approved make and brand with necessary specials like shoes, bends and offsets fixed with, iron clamps, wall plugs, screws, including cost of materials, labour, curing complete etc complete as per direction of the Engineer incharge of the work. | m | 453.6 | 453.6 | 12.4 | False | None | None | False | None | False | 5624.64 | 0 | 4077919 | 158705 | None | code12 | Providing and fixing brass stop cock of approved quality etc complete as per direction of the Engineer incharge of the work. | Nos | 313.95 | 313.95 | 14.0 | False | None | None | False | None | False | 4395.3 | 0 | 4077920 | 158705 | None | code13 | Providing and fixing gun metal non- return valve of approved quality (screwed end) etc complete as per direction of the Engineer incharge of the work. | Nos | 651.0 | 651.0 | 3.0 | False | None | None | False | None | False | 1953.0 | 0 | 4077921 | 158705 | None | code14 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction etc complete as per direction of the Engineer incharge of the work. | Sqm | 603.75 | 603.75 | 72.16 | False | None | None | False | None | False | 43566.6 | 0 |
| 1727326685000 | 0 | None | None | Buildings | Supply of various civil material to Construction of Anganawadi Building | 467304.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4077922 | 158706 | None | code01 | Supplying of Cement etc complete as per direction of the Engineer incharge of the work. | Bag | 293.0 | 293.0 | 295.0 | False | None | None | False | None | False | 86435.0 | 0 | 4077923 | 158706 | None | code02 | Supplying of Sand etc complete as per direction of the Engineer incharge of the work. | Cum | 1476.0 | 1476.0 | 30.05 | False | None | None | False | None | False | 44353.8 | 0 | 4077924 | 158706 | None | code03 | Supplying of 10mm Broken Stone Agaregate etc complete as per direction of the Engineer incharge of the work. | Cum | 1362.0 | 1362.0 | 9.35 | False | None | None | False | None | False | 12734.7 | 0 | 4077925 | 158706 | None | code04 | Supplying of 20mm Broken Stone Agaregate etc complete as per direction of the Engineer incharge of the work. | Cum | 1333.0 | 1333.0 | 16.38 | False | None | None | False | None | False | 21834.54 | 0 | 4077926 | 158706 | None | code05 | Supplying of 40mm Broken Stone Agaregate etc complete as per direction of the Engineer incharge of the work. | Cum | 1190.0 | 1190.0 | 3.47 | False | None | None | False | None | False | 4129.3 | 0 | 4077927 | 158706 | None | code06 | Supplying of Brick etc complete as per direction of the Engineer incharge of the work. | No | 8.0 | 8.0 | 13538.0 | False | None | None | False | None | False | 108304.0 | 0 | 4077928 | 158706 | None | code07 | Supplying of Rubber Stone etc complete as per direction of the Engineer incharge of the work. | Cum | 476.19 | 476.19 | 12.97 | False | None | None | False | None | False | 6176.1843 | 0 | 4077929 | 158706 | None | code08 | Supplying of Concrete Mixer etc complete as per direction of the Engineer incharge of the work. | hr | 369.0 | 369.0 | 10.0 | False | None | None | False | None | False | 3690.0 | 0 | 4077930 | 158706 | None | code09 | Supplying of Vibrator etc complete as per direction of the Engineer incharge of the work. | hr | 411.0 | 411.0 | 15.0 | False | None | None | False | None | False | 6165.0 | 0 | 4077931 | 158706 | None | code10 | Supplying of Manson etc complete as per direction of the Engineer incharge of the work. | Day | 601.0 | 601.0 | 140.0 | False | None | None | False | None | False | 84140.0 | 0 | 4077932 | 158706 | None | code11 | Centring Shutting Work Footing etc complete as per direction of the Engineer incharge of the work. | Sqm | 218.0 | 218.0 | 19.26 | False | None | None | False | None | False | 4198.68 | 0 | 4077933 | 158706 | None | code12 | Centring Shutting Work Column etc complete as per direction of the Engineer incharge of the work. | Sqm | 385.44 | 385.44 | 60.98 | False | None | None | False | None | False | 23504.1312 | 0 | 4077934 | 158706 | None | code13 | Centring Shutting Work Super Structure ( Beam Slab Lintel) etc complete as per direction of the Engineer incharge of the work. | Sqm | 408.18 | 408.18 | 151.01 | False | None | None | False | None | False | 61639.2618 | 0 |
| 1727326685000 | 0 | None | None | Buildings | Electrical Work | 40000.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4077935 | 158707 | None | code1 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm etc complete as per direction of the Engineer incharge of the work. | Mtr | 35.0 | 35.0 | 100.0 | False | None | None | False | None | False | 3500.0 | 0 | 4077936 | 158707 | None | code2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch box | Point | 285.0 | 285.0 | 3.0 | False | None | None | False | None | False | 855.0 | 0 | 4077937 | 158707 | None | code3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 4077938 | 158707 | None | code4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 | 4077939 | 158707 | None | code5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified 1.5 mm2 etc complete as per direction of the Engineer incharge of the work. | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 4077940 | 158707 | None | code6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified 2.5 mm2 etc complete as per direction of the Engineer incharge of the work. | Mtr | 42.0 | 42.0 | 120.0 | False | None | None | False | None | False | 5040.0 | 0 | 4077941 | 158707 | None | code7 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way | Each | 261.0 | 261.0 | 1.0 | False | None | None | False | None | False | 261.0 | 0 | 4077942 | 158707 | None | code8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 319.0 | 319.0 | 1.0 | False | None | None | False | None | False | 319.0 | 0 | 4077943 | 158707 | None | code9 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 284.0 | 284.0 | 1.0 | False | None | None | False | None | False | 284.0 | 0 | 4077944 | 158707 | None | code10 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 | 4077945 | 158707 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.6 Amps one way Switch | Each | 102.0 | 102.0 | 6.0 | False | None | None | False | None | False | 612.0 | 0 | 4077946 | 158707 | None | code12 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.6Amps 3 way Socket | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 | 4077947 | 158707 | None | code13 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.Stepped fan Regulator | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 | 4077948 | 158707 | None | code14 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.32 Amps Dp switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 4077949 | 158707 | None | code15 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.Supplying & Fixing of 70-150 W lamp holder 2 Pin | Each | 63.0 | 63.0 | 4.0 | False | None | None | False | None | False | 252.0 | 0 | 4077950 | 158707 | None | code16 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 157.0 | 157.0 | 2.0 | False | None | None | False | None | False | 314.0 | 0 | 4077951 | 158707 | None | code16 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 | 4077952 | 158707 | None | code17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 4077953 | 158707 | None | code18 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V 50Hz AC power Supply. | Each | 520.0 | 520.0 | 5.0 | False | None | None | False | None | False | 2600.0 | 0 | 4077954 | 158707 | None | code19 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum | Each | 3754.0 | 3754.0 | 3.0 | False | None | None | False | None | False | 11262.0 | 0 | 4077955 | 158707 | None | code20 | SFixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (on wall/ceiling/rafter/girders | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 4077956 | 158707 | None | code21 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 10sqmm | Mtr | 167.0 | 167.0 | 22.54 | False | None | None | False | None | False | 3764.18 | 0 | 4077957 | 158707 | None | code22 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
|
|
---|