4082791 | 158901 | None | 001 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 37.72 | False | None | None | False | None | False | 11842.194 | 0 |
4082792 | 158901 | None | 002 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting Depth exceeding 1.5m, but not exceeding 3 m | Cum | 467.25 | 467.25 | 5.63 | False | None | None | False | None | False | 2630.6175 | 0 |
4082793 | 158901 | None | 003 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 329.65 | 329.65 | 46.44 | False | None | None | False | None | False | 15308.946 | 0 |
4082794 | 158901 | None | 004 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 6.39 | False | None | None | False | None | False | 38002.608 | 0 |
4082795 | 158901 | None | 005 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 | Cum | 6948.9 | 6948.9 | 8.53 | False | None | None | False | None | False | 59274.117 | 0 |
4082796 | 158901 | None | 006 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement | Cum | 6708.45 | 6708.45 | 6.79 | False | None | None | False | None | False | 45550.3755 | 0 |
4082797 | 158901 | None | 007 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8376.9 | 8376.9 | 40.31 | False | None | None | False | None | False | 337672.839 | 0 |
4082798 | 158901 | None | 008 | Providing and laying 40mm size graded coarse aggregates /pebble stones for side as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour etc., | Cum | 1249.5 | 1249.5 | 2.99 | False | None | None | False | None | False | 3736.005 | 0 |
4082799 | 158901 | None | 009 | Providing and laying 100mm size graded coarse aggregates /pebble stones (For filter bed)as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour | Cum | 1200.15 | 1200.15 | 1.81 | False | None | None | False | None | False | 2172.2715 | 0 |
4082800 | 158901 | None | 010 | Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete | Cum | 2285.85 | 2285.85 | 2.78 | False | None | None | False | None | False | 6354.663 | 0 |
4082801 | 158901 | None | 011 | Providing and laying 25mm size graded coarse aggregates /pebble stones (For filter bed)as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour | Cum | 1399.65 | 1399.65 | 0.75 | False | None | None | False | None | False | 1049.7375 | 0 |
4082802 | 158901 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 10442.25 | 10442.25 | 0.52 | False | None | None | False | None | False | 5429.97 | 0 |
4082803 | 158901 | None | 013 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24 Volume 1 (P No: 16 I.No:2.5.1) | Cum | 6961.5 | 6961.5 | 22.12 | False | None | None | False | None | False | 153988.38 | 0 |
4082804 | 158901 | None | 014 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24 Volume 1 (P No: 15 I.No:2.1.4 ) | Cum | 6527.85 | 6527.85 | 4.29 | False | None | None | False | None | False | 28004.4765 | 0 |
4082805 | 158901 | None | 015 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CM SR 2023-24/P.No.16/Vol-1/2.4.2) | Cum | 7303.06 | 7303.06 | 8.082 | False | None | None | False | None | False | 59023.33092 | 0 |
4082806 | 158901 | None | 016 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 82961.55 | 82961.55 | 3.26 | False | None | None | False | None | False | 270454.653 | 0 |
4082807 | 158901 | None | 017 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC Beams, Lintels & Troughs of Aqueducts | Cum | 4176.9 | 4176.9 | 8.05 | False | None | None | False | None | False | 33624.045 | 0 |
4082808 | 158901 | None | 018 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Roof Slab of builing | Cum | 3480.75 | 3480.75 | 7.35 | False | None | None | False | None | False | 25583.5125 | 0 |
4082809 | 158901 | None | 019 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 497.7 | 497.7 | 49.32 | False | None | None | False | None | False | 24546.564 | 0 |
4082810 | 158901 | None | 020 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 334.85 | False | None | None | False | None | False | 113564.3775 | 0 |
4082811 | 158901 | None | 021 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 44.0 | False | None | None | False | None | False | 4111.8 | 0 |
4082812 | 158901 | None | 022 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including. preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in-charge | Sqm | 133.35 | 133.35 | 334.85 | False | None | None | False | None | False | 44652.2475 | 0 |
4082813 | 158901 | None | 023 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral | Each | 5128.2 | 5128.2 | 2.0 | False | None | None | False | None | False | 10256.4 | 0 |
4082814 | 158901 | None | 024 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 41.82 | False | None | None | False | None | False | 39036.879 | 0 |
4082815 | 158901 | None | 025 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour,complete as per specifications | Sqm | 1521.45 | 1521.45 | 23.1 | False | None | None | False | None | False | 35145.495 | 0 |
4082816 | 158901 | None | 026 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 130412.1 | 130412.1 | 0.2 | False | None | None | False | None | False | 26082.42 | 0 |
4082817 | 158901 | None | 027 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials,labour,usage charges complete as per specification | Sqm | 7241.85 | 7241.85 | 18.72 | False | None | None | False | None | False | 135567.432 | 0 |
4082818 | 158901 | None | 028 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Foundation upto Plinth All other types | Cum | 152.4 | 152.4 | 4.42 | False | None | None | False | None | False | 673.608 | 0 |
4082819 | 158901 | None | 029 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC Columns / Shaft (Slip Centering) Form Works | Cum | 3555.93 | 3555.93 | 1.77 | False | None | None | False | None | False | 6293.9961 | 0 |
4082820 | 158901 | None | 030 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 | No | 761.25 | 761.25 | 3.0 | False | None | None | False | None | False | 2283.75 | 0 |
4082821 | 158901 | None | 031 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete | No | 329.7 | 329.7 | 1.0 | False | None | None | False | None | False | 329.7 | 0 |
4082822 | 158901 | None | 032 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excludingcost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or ected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for PVC pipes 25mm dia, 10 kg/sqcm & class 5 | m | 50.4 | 50.4 | 100.0 | False | None | None | False | None | False | 5040.0 | 0 |
4082823 | 158901 | None | 033 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | No | 16.8 | 16.8 | 5.0 | False | None | None | False | None | False | 84.0 | 0 |
4082824 | 158901 | None | 034 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | No | 22.05 | 22.05 | 5.0 | False | None | None | False | None | False | 110.25 | 0 |
4082825 | 158901 | None | 035 | Providing and placing on terrace at all floor levels polyethylene water storage tanks IS 12701marked with cover and suitable locking arrangements, making necessary holes for inlet outlet and over flow pipes but with out fittings and the base support for tank | Per Litre | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
4082826 | 158901 | None | 036 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:( PVC pipes 140mm dia., 6 kg/sqcm & class 3 | m | 613.2 | 613.2 | 35.0 | False | None | None | False | None | False | 21462.0 | 0 |
4082827 | 158901 | None | 037 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 231.0 | 231.0 | 65.0 | False | None | None | False | None | False | 15015.0 | 0 |
4082828 | 158901 | None | 038 | Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap | Each | 3693.9 | 3693.9 | 2.0 | False | None | None | False | None | False | 7387.8 | 0 |
4082829 | 158901 | None | 039 | Supply and delivery at site special moulded variety 140 mm dia PVC Elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Each | 374.85 | 374.85 | 2.0 | False | None | None | False | None | False | 749.7 | 0 |
4082830 | 158901 | None | 040 | Providing fixing of louvered ventilator made out of multi chambered UPVCMatching to RAL-016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along ith plastic parts for fixing the 4 mm pin headglass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm 1000mm.The cost is inclusive of all fixtures and separate charges for minorTPsshall not be made | Sqm | 6004.95 | 6004.95 | 0.81 | False | None | None | False | None | False | 4864.0095 | 0 |
4082831 | 158901 | None | 041 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Kg | 192.15 | 192.15 | 20.25 | False | None | None | False | None | False | 3891.0375 | 0 |
4082832 | 158901 | None | 042 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Each | 5079.9 | 5079.9 | 1.0 | False | None | None | False | None | False | 5079.9 | 0 |
4082833 | 158901 | None | 043 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector has swivelling unit of aluminium die cast eye ball LED Lamp position retained by circular wire spring with Life of 25000 burning hours 70 lumen maintenance with CRI 80 Power Input: 220-240V 50/60Hz Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 5-6W PWD Electrical SR 2023-24 item. No 11.5.1 page no 44 | Each | 571.0 | 571.0 | 3.0 | False | None | None | False | None | False | 1713.0 | 0 |
4082834 | 158901 | None | 044 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders PWD Electrical SR 2023-24 item. No 13.7.1 & page no 56 | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 |
4082835 | 158901 | None | 045 | Supplying heavy gauge PVC conduit pipe ...... mm
dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick PWD Electrical SR 2023-24 item. No 1.2.1 & page no 2 | Mtr | 66.0 | 66.0 | 50.0 | False | None | None | False | None | False | 3300.0 | 0 |
4082836 | 158901 | None | 046 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thickPWD Electrical SR 2023-24 item. No 1.1.1 & page no2 | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 |
4082837 | 158901 | None | 047 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. PWD Electrical SR 2023-24 item. No 5.44.3 & page no 21 | Each | 6867.0 | 6867.0 | 1.0 | False | None | None | False | None | False | 6867.0 | 0 |
4082838 | 158901 | None | 048 | Grounding of towers including cost of 40 mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 metres length as per specifications, with 50 X 6 mm GI Flats 3 metre long,
salt charcoal, including excavation charges.KPTCL Electrical SR 2021-22 item. No 11 a & 12 | Set | 4950.0 | 4950.0 | 1.0 | False | None | None | False | None | False | 4950.0 | 0 |
4082839 | 158901 | None | 049 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 mm2 PWD Electrical SR 2023-24 item. No 2.3.2 & page no5 | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
4082840 | 158901 | None | 050 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 PWD Electrical SR 2023-24 item. No 2.3.3 & page no 5 | Mtr | 42.0 | 42.0 | 75.0 | False | None | None | False | None | False | 3150.0 | 0 |
4082841 | 158901 | None | 051 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4.0 mm2 PWD Electrical SR 2023-24 item. No 2.3.4 & page no 5 | Mtr | 63.0 | 63.0 | 50.0 | False | None | None | False | None | False | 3150.0 | 0 |
4082842 | 158901 | None | 052 | Supplying and fixing PVC/metal conduit Deep junction
box. 19/20mm deep junction box PWD Electrical SR 2023-24 item. No 1.5.1 page no 2 | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
4082843 | 158901 | None | 053 | Fabricating supplying and mounting MS box made out
....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG PWD Electrical SR 2023-24 item. No 5.42.1 & page no 20 | Sq CM | 0.5 | 0.5 | 3000.0 | False | None | None | False | None | False | 1500.0 | 0 |
4082844 | 158901 | None | 054 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 6.4.5 3.5 core 25 sqmm PWD Electrical SR 2019-20
Item 6.4.5
page 40 | Mtr | 180.0 | 180.0 | 20.0 | False | None | None | False | None | False | 3600.0 | 0 |
4082845 | 158901 | None | 055 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole PWD Electrical SR 2023-24 item. No 5.20.1 & page no 18 | Each | 4277.0 | 4277.0 | 2.0 | False | None | None | False | None | False | 8554.0 | 0 |
4082846 | 158901 | None | 056 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the
poles simultaneously and they shall have a single mechanism. 100 A 25 kA PWD Electrical SR 2023-24 item. No 5.15.9 & page no 17 | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
4082847 | 158901 | None | 057 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP PWD Electrical SR 2023-24 item. No 5.18.4 & page no 17 | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 |
4082848 | 158901 | None | 058 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN PWD Electrical SR 2023-24 item. No 5.18.7 & page no 17 | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
4082849 | 158901 | None | 059 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP PWD Electrical SR 2023-24 item. No 5.18.1 & page no 17 | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
4082850 | 158901 | None | 060 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 way PWD Electrical SR 2023-24, sl. No. 3.3.3page no 8 | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 |
4082851 | 158901 | None | 061 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 way PWD Electrical SR 2023-24, sl. No. 3.3.4 page no 8 | Each | 173.0 | 173.0 | 2.0 | False | None | None | False | None | False | 346.0 | 0 |
4082852 | 158901 | None | 062 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 way PWD Electrical SR 2023-24, sl. No. 3.4.3 page no 8 | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
4082853 | 158901 | None | 063 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way PWD Electrical SR 2023-24, sl. No. 3.4.4 page no 8 | Each | 220.0 | 220.0 | 2.0 | False | None | None | False | None | False | 440.0 | 0 |
4082854 | 158901 | None | 064 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module PWD Electrical SR 2023-24, sl. No. 3.5.3 page no 8 | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
4082855 | 158901 | None | 065 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module PWD Electrical SR 2023-24, sl. No. 3.5.4 page no 8 | Each | 234.0 | 234.0 | 2.0 | False | None | None | False | None | False | 468.0 | 0 |
4082856 | 158901 | None | 066 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module PWD Electrical SR 2023-24, sl. No. 3.5.5 page no 8 | Each | 284.0 | 284.0 | 3.0 | False | None | None | False | None | False | 852.0 | 0 |
4082857 | 158901 | None | 067 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket PWD Electrical SR 2023-24, sl. No. 3.6.10page no 9 | Each | 236.0 | 236.0 | 15.0 | False | None | None | False | None | False | 3540.0 | 0 |