createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727360836399
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee560.00
emd53360.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose14-10-2024 17:00:00
tenderQueryClose10-10-2024 17:00:00
technicalBidOpenNone
publishedDate26-09-2024 20:11:24
publishedByPostCMC_MCOM_HSPT
publishedByUserKPE13256 - CHANDRAPPA C
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMUNICIPAL COMMISSIONER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08394224041
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1727360836432
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT30179
titlePackage 1 1Construction of SamudayaBhavan for Physically Challenged Near Rayara Temple at Ward no 19 in Hosapete City. 2 Development of ValmikiSamudayaBhavan at Ward no 5 in Hosapete City. 3 Construction of SamudayaBhavan at Ward no 26 in Hosapete City.
descriptionPackage 1 1Construction of SamudayaBhavan for Physically Challenged Near Rayara Temple at Ward no 19 in Hosapete City. 2 Development of ValmikiSamudayaBhavan at Ward no 5 in Hosapete City. 3 Construction of SamudayaBhavan at Ward no 26 in Hosapete City.
categoryWORKS
categoryTextWorks
ecv2216079.15
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2475
locationNameDMA City Municipal Council Hosapete
provisionalAmount2668000.0
groupOverheadTotalNone
fileNumberCMC/HPT/SFC/1/2/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17273608360000NoneNoneBuildingsPackage 1 1Construction of SamudayaBhavan for Physically Challenged Near Rayara Temple at Ward no 19 in Hosapete City.616885.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4088284159193Nonecode01Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m Vol I Common SR 2023 -24 Item No.1.4.2 Page No.05Cum271.95271.9516.97FalseNoneNoneFalseNoneFalse4614.99150
4088285159193Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD DSR 2023-24 Volume-I Item No. 2.1.2 Page No. 15Cum5947.25947.23.08FalseNoneNoneFalseNoneFalse18317.3760
4088286159193Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Vol II Building SR- 2023-24 Item No.5.1.1 Page No. 09Cum5891.555891.553.92FalseNoneNoneFalseNoneFalse23094.8760
4088287159193Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Vol II Building SR- 2023-24 Item No.5.4 Page No. 09Cum6708.456708.453.37FalseNoneNoneFalseNoneFalse22607.47650
4088288159193Nonecode05Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Vol I Commom SR 2023-24 Item No.2.2.1 Page No. 15Cum6799.396799.392.03FalseNoneNoneFalseNoneFalse13802.76170
4088289159193Nonecode06Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.2.4.2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m Vol I Commom SR 2023-24 Item No.2.4.2 Page No. 17Cum11286.5611286.560.26FalseNoneNoneFalseNoneFalse2934.50560
4088290159193Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Vol I Commom SR 2023-24 Item No.2.5.2 Page No.17Cum12214.7612214.760.97FalseNoneNoneFalseNoneFalse11848.31720
4088291159193Nonecode08Beam & LintelCum11496.2411496.243.89FalseNoneNoneFalseNoneFalse44720.37360
4088292159193Nonecode09Roof slabCum10777.7310777.733.65FalseNoneNoneFalseNoneFalse39338.71450
4088293159193Nonecode10Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification . All other type of structures volume-III (DSR 2023-24, I.No.2.11 P.No.18) ht82961.5582961.551.24FalseNoneNoneFalseNoneFalse102872.3220
4088294159193Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol I Common SR - 2023-24 Item No.1.9 Page No. 07Cum279.3279.328.09FalseNoneNoneFalseNoneFalse7845.5370
4088295159193Nonecode12Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Vol II Building SR- 2023-24 Item No.6.5 Page No. 13Cum11525.8511525.8511.96FalseNoneNoneFalseNoneFalse137849.1660
4088296159193Nonecode13Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol II Building SR- 2023-24 Item No.8.2.1 Page No. 41Sqm309.75309.7568.8FalseNoneNoneFalseNoneFalse21310.80
4088297159193Nonecode14Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol II Building SR- 2023-24 Item No.8.4.1 Page No. 41Sqm339.15339.1574.4FalseNoneNoneFalseNoneFalse25232.760
4088298159193Nonecode15Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. 600 x 600 mm Vol II Building SR- 2023-24 Item No.9.12.1 Page No. 60Sqm1136.11136.116.0FalseNoneNoneFalseNoneFalse18177.60
4088299159193Nonecode16Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer in-charge. Vol II Building SR- 2023-24 Item No.8.21 Page No. 44Sqm27.327.3143.2FalseNoneNoneFalseNoneFalse3909.360
4088300159193Nonecode17Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol II Building SR- 2022 Item No.8.25 Page No. 45Sqm143.85143.85143.2FalseNoneNoneFalseNoneFalse20599.320
4088301159193Nonecode18Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol II Building SR- 2023-24 Item No.11.2 Page No. 77Kgs118.65118.6560.0FalseNoneNoneFalseNoneFalse7119.00
4088302159193Nonecode19Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) Vol II Building SR- 2023-24 Item No.12.15 Page No. 77Sqm7241.857241.855.4FalseNoneNoneFalseNoneFalse39105.990
4088303159193Nonecode20Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. Vol II Building SR- 2023-24 Item No.12.15 Page No. 77Sqm1667.41667.42.52FalseNoneNoneFalseNoneFalse4201.8480
4088304159193Nonecode21Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr64.0564.0550.0FalseNoneNoneFalseNoneFalse3202.50
4088305159193Nonecode22Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallMtr27.327.350.0FalseNoneNoneFalseNoneFalse1365.00
4088306159193Nonecode23Supplying and fixing PVC/metal conduit accessories: 19/20mm Special type junction box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work.Each64.0564.0510.0FalseNoneNoneFalseNoneFalse640.50
4088307159193Nonecode24Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach241.5241.52.0FalseNoneNoneFalseNoneFalse483.00
4088308159193Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each92.492.410.0FalseNoneNoneFalseNoneFalse924.00
4088309159193Nonecode26Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work.Mtr289.8289.810.0FalseNoneNoneFalseNoneFalse2898.00
4088310159193Nonecode27Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board - c) 32-40 Amps 4 poleEach2967.32967.31.0FalseNoneNoneFalseNoneFalse2967.30
4088311159193Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010Mtr27.327.370.0FalseNoneNoneFalseNoneFalse1911.00
4088312159193Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010Mtr42.042.070.0FalseNoneNoneFalseNoneFalse2940.00
4088313159193Nonecode30Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.Each105.0105.02.0FalseNoneNoneFalseNoneFalse210.00
4088314159193Nonecode31Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & completely wired on existing box.Each784.35784.352.0FalseNoneNoneFalseNoneFalse1568.70
4088315159193Nonecode32Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.Each1367.11367.12.0FalseNoneNoneFalseNoneFalse2734.20
4088316159193Nonecode33Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 0898. (I. No 5.18.4 P. No. 17 of 105, of PWD Ele SR 2023-24)Each549.15549.152.0FalseNoneNoneFalseNoneFalse1098.30
4088317159193Nonecode34Supplying of ......feet - PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each520.8520.88.0FalseNoneNoneFalseNoneFalse4166.40
4088318159193Nonecode35Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each510.3510.38.0FalseNoneNoneFalseNoneFalse4082.40
4088319159193Nonecode36Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1619.11619.110.0FalseNoneNoneFalseNoneFalse16191.00
17273608360000NoneNoneBuildingsPackage1 2 Development of Valmiki Samudaya Bhavan at Ward no 5 in Hosapete City.1270567.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4088320159194Nonecode01Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m Vol I Common SR 2023 -24 Item No.1.4.2 Page No.05Cum271.95271.9538.64FalseNoneNoneFalseNoneFalse10508.1480
4088321159194Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD DSR 2023-24 Volume-I Item No. 2.1.2 Page No. 15Cum5947.25947.26.69FalseNoneNoneFalseNoneFalse39786.7680
4088322159194Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Vol II Building SR- 2023-24 Item No.5.1.1 Page No. 09Cum5891.555891.556.487FalseNoneNoneFalseNoneFalse38218.484850
4088323159194Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Vol II Building SR- 2023-24 Item No.5.4 Page No. 09Cum6708.456708.456.12FalseNoneNoneFalseNoneFalse41055.7140
4088324159194Nonecode05Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Vol I Commom SR 2023-24 Item No.2.2.1 Page No. 15Cum6799.396799.398.1FalseNoneNoneFalseNoneFalse55075.0590
4088325159194Nonecode06Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.2.4.2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m Vol I Commom SR 2023-24 Item No.2.4.2 Page No. 17Cum11286.5611286.561.38FalseNoneNoneFalseNoneFalse15575.45280
4088326159194Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Vol I Commom SR 2023-24 Item No.2.5.2 Page No.17Cum12214.7612214.765.8FalseNoneNoneFalseNoneFalse70845.6080
4088327159194Nonecode08Beam & LintelCum11496.2411496.247.6FalseNoneNoneFalseNoneFalse87371.4240
4088328159194Nonecode09Roof slabCum10777.7310777.737.79FalseNoneNoneFalseNoneFalse83958.51670
4088329159194Nonecode10Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification . All other type of structures volume-III (DSR 2023-24, I.No.2.11 P.No.18) ht82961.5582961.553.89FalseNoneNoneFalseNoneFalse322720.42950
4088330159194Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol I Common SR - 2023-24 Item No.1.9 Page No. 07Cum279.3279.368.61FalseNoneNoneFalseNoneFalse19162.7730
4088331159194Nonecode12Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Vol II Building SR- 2023-24 Item No.6.5 Page No. 13Cum11525.8511525.8515.79FalseNoneNoneFalseNoneFalse181993.17150
4088332159194Nonecode13Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol II Building SR- 2023-24 Item No.8.2.1 Page No. 41Sqm309.75309.75107.5FalseNoneNoneFalseNoneFalse33298.1250
4088333159194Nonecode14Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol II Building SR- 2023-24 Item No.8.4.1 Page No. 41Sqm339.15339.15129.75FalseNoneNoneFalseNoneFalse44004.71250
4088334159194Nonecode15Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. 600 x 600 mm Vol II Building SR- 2023-24 Item No.9.12.1 Page No. 60Sqm1136.11136.138.5FalseNoneNoneFalseNoneFalse43739.850
4088335159194Nonecode16Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer in-charge. Vol II Building SR- 2023-24 Item No.8.21 Page No. 44Sqm27.327.3237.25FalseNoneNoneFalseNoneFalse6476.9250
4088336159194Nonecode17Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol II Building SR- 2022 Item No.8.25 Page No. 45Sqm143.85143.85237.25FalseNoneNoneFalseNoneFalse34128.41250
4088337159194Nonecode18Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol II Building SR- 2023-24 Item No.11.2 Page No. 77Kgs118.65118.65200.0FalseNoneNoneFalseNoneFalse23730.00
4088338159194Nonecode19Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) Vol II Building SR- 2023-24 Item No.12.15 Page No. 77Sqm7241.857241.858.28FalseNoneNoneFalseNoneFalse59962.5180
4088339159194Nonecode20Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. Vol II Building SR- 2023-24 Item No.12.15 Page No. 77Sqm1667.41667.42.52FalseNoneNoneFalseNoneFalse4201.8480
4088340159194Nonecode21Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr64.0564.0570.0FalseNoneNoneFalseNoneFalse4483.50
4088341159194Nonecode22Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallMtr27.327.370.0FalseNoneNoneFalseNoneFalse1911.00
4088342159194Nonecode23Supplying and fixing PVC/metal conduit accessories: 19/20mm Special type junction box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work.Each64.0564.0510.0FalseNoneNoneFalseNoneFalse640.50
4088343159194Nonecode24Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach241.5241.52.0FalseNoneNoneFalseNoneFalse483.00
4088344159194Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each92.492.410.0FalseNoneNoneFalseNoneFalse924.00
4088345159194Nonecode26Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work.Each289.8289.810.0FalseNoneNoneFalseNoneFalse2898.00
4088346159194Nonecode27Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board - c) 32-40 Amps 4 poleEach2967.32967.31.0FalseNoneNoneFalseNoneFalse2967.30
4088347159194Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010Mtr27.327.3150.0FalseNoneNoneFalseNoneFalse4095.00
4088348159194Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010Mtr42.042.0150.0FalseNoneNoneFalseNoneFalse6300.00
4088349159194Nonecode30Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.Each105.0105.02.0FalseNoneNoneFalseNoneFalse210.00
4088350159194Nonecode31Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & completely wired on existing box.Each784.35784.352.0FalseNoneNoneFalseNoneFalse1568.70
4088351159194Nonecode32Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.Each1367.11367.12.0FalseNoneNoneFalseNoneFalse2734.20
4088352159194Nonecode33Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 0898. (I. No 5.18.4 P. No. 17 of 105, of PWD Ele SR 2023-24)Each549.15549.152.0FalseNoneNoneFalseNoneFalse1098.30
4088353159194Nonecode34Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each520.8520.88.0FalseNoneNoneFalseNoneFalse4166.40
4088354159194Nonecode35Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each510.3510.38.0FalseNoneNoneFalseNoneFalse4082.40
4088355159194Nonecode36Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1619.11619.110.0FalseNoneNoneFalseNoneFalse16191.00
17273608360000NoneNoneBuildingsPackage 1 3 Construction of SamudayaBhavan at Ward no 26 in Hosapete City.328626.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4088356159195Nonecode01Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m Vol I Common SR 2023 -24 Item No.1.4.2 Page No.05Cum271.95271.958.94FalseNoneNoneFalseNoneFalse2431.2330
4088357159195Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD DSR 2023-24 Volume-I Item No. 2.1.2 Page No. 15Cum5947.25947.22.1FalseNoneNoneFalseNoneFalse12489.120
4088358159195Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Vol II Building SR- 2023-24 Item No.5.1.1 Page No. 09Cum5891.555891.554.18FalseNoneNoneFalseNoneFalse24626.6790
4088359159195Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Vol II Building SR- 2023-24 Item No.5.4 Page No. 09Cum6708.456708.452.65FalseNoneNoneFalseNoneFalse17777.39250
4088360159195Nonecode05Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Vol I Commom SR 2023-24 Item No.2.2.1 Page No. 15Cum6799.396799.390.8FalseNoneNoneFalseNoneFalse5439.5120
4088361159195Nonecode06Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.2.4.2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates m Vol I Commom SR 2023-24 Item No.2.4.2 Page No. 17Cum11286.5611286.560.25FalseNoneNoneFalseNoneFalse2821.640
4088362159195Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Vol I Commom SR 2023-24 Item No.2.5.2 Page No.17 ColumnsCum12214.7612214.760.91FalseNoneNoneFalseNoneFalse11115.43160
4088363159195Nonecode08Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Vol I Commom SR 2023-24 Item No.2.5.2 Page No.17 Beam & LintelCum11496.2411496.242.13FalseNoneNoneFalseNoneFalse24486.99120
4088364159195Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Vol I Commom SR 2023-24 Item No.2.5.2 Page No.17 Roof slabCum10777.7310777.732.19FalseNoneNoneFalseNoneFalse23603.22870
4088365159195Nonecode10Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification . All other type of structures volume-III (DSR 2023-24, I.No.2.11 P.No.18) ht82961.5582961.550.5FalseNoneNoneFalseNoneFalse41480.7750
4088366159195Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol I Common SR - 2023-24 Item No.1.9 Page No. 07Cum279.3279.311.79FalseNoneNoneFalseNoneFalse3292.9470
4088367159195Nonecode12Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Vol II Building SR- 2023-24 Item No.6.7 Page No. 13Cum8621.558621.559.19FalseNoneNoneFalseNoneFalse79232.04450
4088368159195Nonecode13Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol II Building SR- 2023-24 Item No.8.2.1 Page No. 41Sqm309.75309.7550.68FalseNoneNoneFalseNoneFalse15698.130
4088369159195Nonecode14Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Vol II Building SR- 2023-24 Item No.8.1.1 Page No. 41Sqm267.75267.7560.58FalseNoneNoneFalseNoneFalse16220.2950
4088370159195Nonecode15Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. 600 x 600 mm Vol II Building SR- 2023-24 Item No.9.12.1 Page No. 60Sqm1136.11136.115.0FalseNoneNoneFalseNoneFalse17041.50
4088371159195Nonecode16Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol II Building SR- 2023-24 Item No.8.25 Page No. 45Sqm143.85143.85111.26FalseNoneNoneFalseNoneFalse16004.7510
4088372159195Nonecode17Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol II Building SR- 2023-24 Item No.11.28 Page No. 85Kgs393.25393.2537.8FalseNoneNoneFalseNoneFalse14864.850
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17273608370000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17273608370000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17273608370000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17273608370000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17273608370000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17273608370000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17273608370000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17273608370000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17273608370000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17273608370000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17273608370000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17273608370000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17273608370000NoneNoneELIGIBILITYBanker Details for referenceNone
17273608370000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17273608370000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17273608370000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17273608370000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Registration CertificateTrueTechnical Bid
Qualification A To qualify award of this contract each tenderer in his name should have in the last five years period a achieved in at least two financial years an average annual financial turnover of Estimate CostTrueTechnical Bid
Mandatory Satisfactory completion as a prime contractor for at least 1 similar nature of work 50per of total cost of works. Attested by Executive EngineerTrueTechnical Bid
GST and PANTrueTechnical Bid
EPF Certificate and ClearanceTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone