createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726640332656
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3610.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-10-2024 16:00:00
tenderQueryClose15-10-2024 16:30:00
technicalBidOpen19-10-2024 16:30:00
publishedDate26-09-2024 19:21:12
publishedByPostCMC_MCOM_SRS
publishedByUserKPE12425 - KANTHARAJU H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate27-09-2024 16:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGANESH BHAT JE CMC Sirsi
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08384226338
mobileNumber9448965390
tenderSupplierListNone
tenderSchedule
createdTs1726640332685
version9
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT27795
titleCONSTRUCTION OF PROPOSED 10TDP MRF CENTER (MATERIAL RECOVERY FACILITY) OF PEB STRUCTURE (PRIMERY SHED) AT SIRSI IN SWM SITE.
descriptionCONSTRUCTION OF PROPOSED 10TDP MRF CENTER (MATERIAL RECOVERY FACILITY) OF PEB STRUCTURE (PRIMERY SHED) AT SIRSI IN SWM SITE.
categoryWORKS
categoryTextWorks
ecv14430000.02
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2418
locationNameDMA City Municipal Council Sirsi
provisionalAmount14430000.0
groupOverheadTotal2294676.9
fileNumberCMC/SIRSI/SBM-2/MRF/SWM
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17266403330001NoneNoneBuildingsCONSTRUCTION OF PROPOSED 10TDP MRF CENTER (MATERIAL RECOVERY FACILITY) OF PEB STRUCTURE (PRIMERY SHED) AT SIRSI IN SWM SITE.11711815.78
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4019530155796None1.14.1KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labor, tools, usage of machinery & other appurtenances required to complete the workCum114.24114.24236.34FalseNoneNoneFalseNoneFalse26999.48160
4019531155796None2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.68100.81FalseNoneNoneFalseNoneFalse676201.22080
4019532155796None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum7257.67257.651.04FalseNoneNoneFalseNoneFalse370427.9040
4019533155796None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum7838.217838.219.21FalseNoneNoneFalseNoneFalse72189.91410
4019534155796None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum12337.9212337.92106.21FalseNoneNoneFalseNoneFalse1310410.48320
4019535155796None2.2.3KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum10644.4810644.4810.71FalseNoneNoneFalseNoneFalse114002.38080
4019536155796None2.2.3KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum7805.957805.9567.2FalseNoneNoneFalseNoneFalse524559.840
4019537155796None2.11KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne100191.84100191.8417.0832FalseNoneNoneFalseNoneFalse1711597.2410880
4019538155796None5.4KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum7155.687155.6841.79FalseNoneNoneFalseNoneFalse299035.86720
4019539155796None1.8KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum530.88530.881891.18FalseNoneNoneFalseNoneFalse1003989.63840
4019540155796None6.33KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1378.721378.72274.42FalseNoneNoneFalseNoneFalse378348.34240
4019541155796None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No.8.8 , Page No. 42, Vol.2)Sqm415.52415.52599.37FalseNoneNoneFalseNoneFalse249050.22240
4019542155796None11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs126.56126.5627260.0FalseNoneNoneFalseNoneFalse3450025.60
4019543155796None7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm636.16636.161623.51FalseNoneNoneFalseNoneFalse1032812.12160
4019544155796None8.51KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm112.0112.0599.37FalseNoneNoneFalseNoneFalse67129.440
4019545155796None8.54.1KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm81.7681.76308.0FalseNoneNoneFalseNoneFalse25182.080
4019546155796None11.6.1KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 78, Vol.2)Sqm2948.962948.9634.44FalseNoneNoneFalseNoneFalse101562.18240
4019547155796None11.35.1.1KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 79, Vol.2)Kg27648.3227648.322.0FalseNoneNoneFalseNoneFalse55296.640
4019548155796None11.35.1.1KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg506.24506.24480.0FalseNoneNoneFalseNoneFalse242995.20
17266403330001NoneNoneBuildingsCONSTRUCTION OF PROPOSED 10TDP MRF CENTER (MATERIAL RECOVERY FACILITY) OF PEB STRUCTURE (PRIMERY SHED) AT SIRSI IN SWM SITE.(ELECTRICAL)423507.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4019549155797None1.1LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. (Main Panel) (Incomer : MCCB TPN 100A with CBCT ELR & Ph indicators, meter section with all parameters as required, 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No. Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 02Nos Outgoings: 63/40A MCB feeder- 08NosNo85000.085000.01.0FalseNoneNoneFalseNoneFalse85000.00
4019550155797None1.2Sub panel-1 Incomer: MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required Market price 63A 4 Wire 16kA 415V Aluminums busbars compartment. Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
4019551155797None2.1LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.11 ,CH-1, PAGE NO-13Km178973.0178973.00.045FalseNoneNoneFalseNoneFalse8053.7850
4019552155797None2.2LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx25 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.08 ,CH-1, PAGE NO-13Km179844.0179844.00.1FalseNoneNoneFalseNoneFalse17984.40
4019553155797None2.2LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx16 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.08 ,CH-1, PAGE NO-13Km141842.0141842.00.12FalseNoneNoneFalseNoneFalse17021.040
4019554155797None2.4LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx10 Sqmm Cu Ar cableMtr332.0332.05.0FalseNoneNoneFalseNoneFalse1660.00
4019555155797None2.5LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx6.0 Sqmm Cu Ar cableMtr256.0256.05.0FalseNoneNoneFalseNoneFalse1280.00
4019556155797None2.6LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3Cx6.0 Sqmm Cu Un Ar cableMtr316.0316.05.0FalseNoneNoneFalseNoneFalse1580.00
4019557155797None2.7LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54.3Cx4.0 Sqmm Cu Un Ar cableMtr300.0300.05.0FalseNoneNoneFalseNoneFalse1500.00
4019558155797None3.1Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
4019559155797None4.24Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
4019560155797None3.34Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
4019561155797None3.44Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4019562155797None3.54Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4019563155797None3.63Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4019564155797None3.73Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4019565155797None3.8Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
4019566155797None3.925 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
4019567155797None3.1016 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
4019568155797None3.1110 Sqmm Cu Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
4019569155797None3.126.0 Sqmm Cu Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4019570155797None3.136.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4019571155797None3.144.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4019572155797None4.1PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduitMtr69.069.024.0FalseNoneNoneFalseNoneFalse1656.00
4019573155797None4.225mm dia PVC 2mm thick conduitMtr81.081.040.0FalseNoneNoneFalseNoneFalse3240.00
4019574155797None5.1Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch boardPoint285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
4019575155797None5.21 Light point above 3M upto 6Mtr from switch boardPoint394.0394.010.0FalseNoneNoneFalseNoneFalse3940.00
4019576155797None5.31 Light point above 6M upto 10Mtr from switch boardPoint570.0570.015.0FalseNoneNoneFalseNoneFalse8550.00
4019577155797None5.42 Light point above 3Mtr upto 6Mtr from switch boardPoint708.0708.05.0FalseNoneNoneFalseNoneFalse3540.00
4019578155797None5.52 Light point above 6Mtr upto 10Mtr from switch boardPoint721.0721.010.0FalseNoneNoneFalseNoneFalse7210.00
4019579155797None5.63 Light point above 6Mtr upto 10Mtr from switch boardPoint1035.01035.015.0FalseNoneNoneFalseNoneFalse15525.00
4019580155797None6.1Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wireMtr19.019.0250.0FalseNoneNoneFalseNoneFalse4750.00
4019581155797None6.21.5 Sqmm Cu FRLS wireMtr26.026.0250.0FalseNoneNoneFalseNoneFalse6500.00
4019582155797None6.32.5 Sqmm Cu FRLS wireMtr42.042.0250.0FalseNoneNoneFalseNoneFalse10500.00
4019583155797None6.44.0 Sqmm Cu FRLS wireMtr63.063.050.0FalseNoneNoneFalseNoneFalse3150.00
4019584155797None6.56.0 Sqmm Cu FRLS wireMtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
4019585155797None7.1Switches & sockets outlets in Existing modular box Supplying of Ceiling Fan 48'' Sweep 5 Star (1200mm)Each2677.02677.09.0FalseNoneNoneFalseNoneFalse24093.00
4019586155797None7.2Stepped fan regulatorNo357.0357.010.0FalseNoneNoneFalseNoneFalse3570.00
4019587155797None7.36/16A Universal socketNos236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
4019588155797None7.4Fixing Charge A Celing/ Wall Mounting FanEach171.0171.010.0FalseNoneNoneFalseNoneFalse1710.00
4019589155797None7.56 Way Polycarbonate switch boxEach173.0173.04.0FalseNoneNoneFalseNoneFalse692.00
4019590155797None7.610 - 12 Way Polycarbonate switch boxEach261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
4019591155797None7.76 Module Polycarbonate switch PlateEach234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
4019592155797None7.810 - 12 Module Polycarbonate switch PlateEach344.0344.02.0FalseNoneNoneFalseNoneFalse688.00
4019593155797None8.1Light fixture Supply & fixing of 100W LED light fixture IP 65, included screws accessoris Etc.Considered outdoor type light fitting for equivalent.No9486.09486.010.0FalseNoneNoneFalseNoneFalse94860.00
4019594155797None9.1Earthing 25x6mm GI Earth StripMtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
4019595155797None10.1Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mmMtr587.0587.050.0FalseNoneNoneFalseNoneFalse29350.00
4019596155797None11.1Pipe Grounding GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 KgNo743.0743.010.0FalseNoneNoneFalseNoneFalse7430.00
4019597155797None11.2Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each.No676.0676.010.0FalseNoneNoneFalseNoneFalse6760.00
4019598155797None11.3Good Quality Salt for grounding purposes packed in 50 Kg gunny bag.No310.0310.08.0FalseNoneNoneFalseNoneFalse2480.00
17266680180001NoneNoneBuildingsCONSTRUCTION OF PROPOSED 10TDP MRF CENTER (MATERIAL RECOVERY FACILITY) OF PEB STRUCTURE (PRIMERY SHED) AT SIRSI IN SWM SITE.12135323.12
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4025592156032None1.14.1KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labor, tools, usage of machinery & other appurtenances required to complete the workCum114.24114.24236.34FalseNoneNoneFalseNoneFalse26999.48160
4025611156032None1.1LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. (Main Panel) (Incomer : MCCB TPN 100A with CBCT ELR & Ph indicators, meter section with all parameters as required, 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No. Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 02Nos Outgoings: 63/40A MCB feeder- 08NosNo85000.085000.01.0FalseNoneNoneFalseNoneFalse85000.00
4025612156032None1.2Sub panel-1 Incomer: MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required Market price 63A 4 Wire 16kA 415V Aluminums busbars compartment. Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
4025593156032None2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.68100.81FalseNoneNoneFalseNoneFalse676201.22080
4025594156032None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum7257.67257.651.04FalseNoneNoneFalseNoneFalse370427.9040
4025613156032None2.1LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.11 ,CH-1, PAGE NO-13Km178973.0178973.00.045FalseNoneNoneFalseNoneFalse8053.7850
4025595156032None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum7838.217838.219.21FalseNoneNoneFalseNoneFalse72189.91410
4025614156032None2.2LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx25 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.08 ,CH-1, PAGE NO-13Km179844.0179844.00.1FalseNoneNoneFalseNoneFalse17984.40
4025596156032None2.3.2KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3Cum12337.9212337.92106.21FalseNoneNoneFalseNoneFalse1310410.48320
4025615156032None2.2LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx16 Sqmm Al Ar cable CSR Electrical SR-2023-24, ITEM NO:32.08 ,CH-1, PAGE NO-13Km141842.0141842.00.12FalseNoneNoneFalseNoneFalse17021.040
4025616156032None2.4LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx10 Sqmm Cu Ar cableMtr332.0332.05.0FalseNoneNoneFalseNoneFalse1660.00
4025597156032None2.2.3KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum10644.4810644.4810.71FalseNoneNoneFalseNoneFalse114002.38080
4025617156032None2.5LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx6.0 Sqmm Cu Ar cableMtr256.0256.05.0FalseNoneNoneFalseNoneFalse1280.00
4025598156032None2.2.3KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum7805.957805.9567.2FalseNoneNoneFalseNoneFalse524559.840
4025599156032None2.11KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne100191.84100191.8417.0832FalseNoneNoneFalseNoneFalse1711597.2410880
4025618156032None2.6LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3Cx6.0 Sqmm Cu Un Ar cableMtr316.0316.05.0FalseNoneNoneFalseNoneFalse1580.00
4025600156032None5.4KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum7155.687155.6841.79FalseNoneNoneFalseNoneFalse299035.86720
4025619156032None2.7LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54.3Cx4.0 Sqmm Cu Un Ar cableMtr300.0300.05.0FalseNoneNoneFalseNoneFalse1500.00
4025601156032None1.8KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum530.88530.881891.18FalseNoneNoneFalseNoneFalse1003989.63840
4025620156032None3.1Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
4025621156032None4.24Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
4025602156032None6.33KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1378.721378.72274.42FalseNoneNoneFalseNoneFalse378348.34240
4025603156032None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No.8.8 , Page No. 42, Vol.2)Sqm415.52415.52599.37FalseNoneNoneFalseNoneFalse249050.22240
4025622156032None3.34Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
4025623156032None3.44Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4025604156032None11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs126.56126.5627260.0FalseNoneNoneFalseNoneFalse3450025.60
4025624156032None3.54Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4025605156032None7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm636.16636.161623.51FalseNoneNoneFalseNoneFalse1032812.12160
4025606156032None8.51KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm112.0112.0599.37FalseNoneNoneFalseNoneFalse67129.440
4025625156032None3.63Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4025607156032None8.54.1KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm81.7681.76308.0FalseNoneNoneFalseNoneFalse25182.080
4025626156032None3.73Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
4025608156032None11.6.1KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 78, Vol.2)Sqm2948.962948.9634.44FalseNoneNoneFalseNoneFalse101562.18240
4025627156032None3.8Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
4025628156032None3.925 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
4025609156032None11.35.1.1KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 79, Vol.2)Kg27648.3227648.322.0FalseNoneNoneFalseNoneFalse55296.640
4025629156032None3.1016 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
4025610156032None11.35.1.1KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg506.24506.24480.0FalseNoneNoneFalseNoneFalse242995.20
4025630156032None3.1110 Sqmm Cu Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
4025631156032None3.126.0 Sqmm Cu Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4025632156032None3.136.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4025633156032None3.144.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
4025634156032None4.1PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduitMtr69.069.024.0FalseNoneNoneFalseNoneFalse1656.00
4025635156032None4.225mm dia PVC 2mm thick conduitMtr81.081.040.0FalseNoneNoneFalseNoneFalse3240.00
4025636156032None5.1Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch boardPoint285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
4025637156032None5.21 Light point above 3M upto 6Mtr from switch boardPoint394.0394.010.0FalseNoneNoneFalseNoneFalse3940.00
4025638156032None5.31 Light point above 6M upto 10Mtr from switch boardPoint570.0570.015.0FalseNoneNoneFalseNoneFalse8550.00
4025639156032None5.42 Light point above 3Mtr upto 6Mtr from switch boardPoint708.0708.05.0FalseNoneNoneFalseNoneFalse3540.00
4025640156032None5.52 Light point above 6Mtr upto 10Mtr from switch boardPoint721.0721.010.0FalseNoneNoneFalseNoneFalse7210.00
4025641156032None5.63 Light point above 6Mtr upto 10Mtr from switch boardPoint1035.01035.015.0FalseNoneNoneFalseNoneFalse15525.00
4025642156032None6.1Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wireMtr19.019.0250.0FalseNoneNoneFalseNoneFalse4750.00
4025643156032None6.21.5 Sqmm Cu FRLS wireMtr26.026.0250.0FalseNoneNoneFalseNoneFalse6500.00
4025644156032None6.32.5 Sqmm Cu FRLS wireMtr42.042.0250.0FalseNoneNoneFalseNoneFalse10500.00
4025645156032None6.44.0 Sqmm Cu FRLS wireMtr63.063.050.0FalseNoneNoneFalseNoneFalse3150.00
4025646156032None6.56.0 Sqmm Cu FRLS wireMtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
4025647156032None7.1Switches & sockets outlets in Existing modular box Supplying of Ceiling Fan 48'' Sweep 5 Star (1200mm)Each2677.02677.09.0FalseNoneNoneFalseNoneFalse24093.00
4025648156032None7.2Stepped fan regulatorNo357.0357.010.0FalseNoneNoneFalseNoneFalse3570.00
4025649156032None7.36/16A Universal socketNos236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
4025650156032None7.4Fixing Charge A Celing/ Wall Mounting FanEach171.0171.010.0FalseNoneNoneFalseNoneFalse1710.00
4025651156032None7.56 Way Polycarbonate switch boxEach173.0173.04.0FalseNoneNoneFalseNoneFalse692.00
4025652156032None7.610 - 12 Way Polycarbonate switch boxEach261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
4025653156032None7.76 Module Polycarbonate switch PlateEach234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
4025654156032None7.810 - 12 Module Polycarbonate switch PlateEach344.0344.02.0FalseNoneNoneFalseNoneFalse688.00
4025655156032None8.1Light fixture Supply & fixing of 100W LED light fixture IP 65, included screws accessoris Etc.Considered outdoor type light fitting for equivalent.No9486.09486.010.0FalseNoneNoneFalseNoneFalse94860.00
4025656156032None9.1Earthing 25x6mm GI Earth StripMtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
4025657156032None10.1Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mmMtr587.0587.050.0FalseNoneNoneFalseNoneFalse29350.00
4025658156032None11.1Pipe Grounding GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 KgNo743.0743.010.0FalseNoneNoneFalseNoneFalse7430.00
4025659156032None11.2Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each.No676.0676.010.0FalseNoneNoneFalseNoneFalse6760.00
4025660156032None11.3Good Quality Salt for grounding purposes packed in 50 Kg gunny bag.No310.0310.08.0FalseNoneNoneFalseNoneFalse2480.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17266403350000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17266403350000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17266403350001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility KPPP portal due to internet connectivity issues and technical glitches at bidders end.None
17266403350000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17266403350000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17266620050000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e- Procurement on or before the last date and time of bid submission.None
17266620240000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one singletransaction and payments made in part are liable for rejection.None
17266621030000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value Min Rs.500 Max Rs.7500 soon after contract has been issued to bidderNone
17266621360000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17266624200000NoneNoneELIGIBILITYAs per Karnataka State Government Order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No PW/134/BMS/2007 Dated 27.7.2007 a sum amounting to 1 % of the bill amount will be deducted towards Construction Labor Welfare fund.None
17266624460000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17266624620000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17266624820000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, lab our, hire charges of machinery curing for concrete works, and all other incidental charges necessary for successful completion of works as per the direction of Engineer in charge of this work.None
17266625940000NoneNoneELIGIBILITYThe Tendered shall obtain the work done certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid the Original Certificate/ Certificates shall be produced at the time of opening of technical Bids for physical verificationNone
17266626320000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17266626480000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reasonNone
17266626670000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing eprocurement portalNone
17266629540000NoneNoneELIGIBILITYTender shall note that the Tenders of those found Eligible as mentioned in Clause 3-Qualification of tenderer in section 2 Qualification of the Tenderer in Section 2 : Instructions to Tenderer I T T will only be considered for evaluationNone
17266629900000NoneNoneELIGIBILITYTo Qualify or award of this contract, each bidder should give all details and documents as per technical and financial bid attached to this tenderNone
17266630380000NoneNoneELIGIBILITYThe bidders shall bear all costs associated with the preparation and submission of each tender, and the employer will in no case be responsible and liable for those costs.None
17266630880001NoneNoneELIGIBILITYAll materials required for this work shall be procured by the bidder himself and should get tested by the quality control authorities at his own cost before use on the work.None
17266631350003NoneNoneELIGIBILITYThe tenderer should maintain the Building / Shed during the period of 24Months.None
17266635320000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next sectionNone
17266648210000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17266648960000NoneNoneELIGIBILITYThe Tenderer should be a KPWD Registered contractor as per Bid DocumentNone
17266649270000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the standard tender documents KW-4 KPWD and further orders thereon.None
17266652700000NoneNoneELIGIBILITYMaintenance Period is 24 months (including monsoon.)None
17266655310000NoneNoneELIGIBILITYEMD Part (1) Rs. 200000/-by e-payment in favor of Municipal Commissioner CMC SirsiNone
17266655970000NoneNoneELIGIBILITYSuccessful bidder should produce 5% of the Contract price plus difference amount for unbalanced tenders in accordance with Clause 25.5 of ITT and Clause 44 of the Conditions of Contract.None
17266656240000NoneNoneELIGIBILITYAny deviation / error / mistake found in units of items, they should be read as in the unified SR 2023-24 and the rates shall be quoted accordinglyNone
17266656520000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17266657370000NoneNoneELIGIBILITYThe Estimate rates are exclusive of 18% GSTNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNone3.2 B) To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2019-20 2020-21, 2021-22, 2022-23 & 2023-24 Satisfactorily completed as prime contractor, at least one similar nature of work such as Building/ Shed work of value not less than Rs.60.675 Lakhs.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneMinimum 80% Quantity Executed in One year as per Bid DocumentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 242.70Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2019-20 2020-21 2021-22, 2022-23, 2023-24) Achieved in at least Two Financial years a minimum annual financial turnover Rs.242.70 Lakhs(in all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnual Financial Turnover Certificate for the last five years i.e from 2019-20 to 2023-24, UDIN is preferred in Turnover certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLINE OF CREDIT CERTIFICATEFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneKPWD REGISTRATION CERTIFICATEOthersKPWD REGISTRATION CERTIFICATE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneList of existing commitments and ongoing workOthersList of existing commitments and ongoing work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing work LIST
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works for which tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
NoneNoneNoneNoneBID CAPACITY A X N X 1.50 - BOthersBID CAPACITY A X N X 1.50 - B
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY A X N X 1.50 - B
NoneNoneNoneNonePAN CARDOthersPAN CARD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN CARD
NoneNoneNoneNoneADRESS PROOFOthersADRESS PROOF
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- ADRESS PROOF
NoneNoneNoneNoneGST Registration CertificateOthersGST Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneGST Clearance CertificateOthersGST Clearance Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST Clearance Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Financial Turnover Certificate for the last five years i.e from 2019-20 to 2023-24, UDIN is preferred in Turnover certificate.TrueTechnical Bid
KPWD Registration CertificateTrueTechnical Bid
SIMILAR NATURE OF WORKDONE CERTIFICATETrueTechnical Bid
ITEMWISE WORKDONETrueTechnical Bid
LINE OF CREDIT CERTIFICATETrueTechnical Bid
GST REGISTRATION AND CLEARENCE CERTIFICATETrueTechnical Bid
List of existing commitments and ongoing workTrueTechnical Bid
List of works for which tenders already submittedTrueTechnical Bid
PAN CARDTrueTechnical Bid
Address ProofTrueTechnical Bid
Bid Capacity A x N x 1.50 - BTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1727092512000
version0
createdDateNone
modifiedDateNone
blockNumberCITY MUNICIPAL COUNCIL, SIRSI
streetNone
citySIRSI
stateKarnataka
pin581402
tenderRecallDTONone