1727351635000 | 0 | None | None | Water supply/sewage lines | Estimate for the work of providing & laying 450mm dia pipe with specials to install the Booster pump in 300mm dia pipe line & construction of RCC chamber for booster pump at Veerannapalya signal on emergency basis coming under kempapura S/stn of AEEN-1-1 sub division | 812675.85 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4086361 | 159098 | None | code01 | Supplying of Model No. NMT500A+NET150D Texmo make horizontal mounted submersible pump set with radial flow three phase motor being winded with PVC insulated copper winding wire, wear resistant high strength impellers and diffusers with stainless steel inserts, stain steel stage housings, water lubricated motor with heavy duty tilting pad thrust bearing suitable for 3 phase 440 V 50 Hz. Power supply with rigid cast iron construction with heavy brass large bush bearing for better life, dynamically balanced motor eigid cast iron body casing and balanced impeller, stainless steel shaft sleeve with gunmetal packing gland and stainless steel studs & brass impeller rock nuts and having delivery size 250 & capable of discharges from 17mts to 32mts at discharges of 3900 1pm to 1200 1pm with 8 mtrs of cable size 2x3x10 sqmm Copper Flat Cable 1set. (As per the Check quotation of M/S Eco Energy Engineering) 20 HP Booster Pump | No | 112500.0 | 112500.0 | 1.0 | False | None | None | False | None | False | 112500.0 | 0 | 4086362 | 159098 | None | code02 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete. 6 to 15 HP pumps | No | 15900.0 | 15900.0 | 1.0 | False | None | None | False | None | False | 15900.0 | 0 | 4086363 | 159098 | None | code03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) | m | 207194.0 | 207194.0 | 0.04 | False | None | None | False | None | False | 8287.76 | 0 | 4086364 | 159098 | None | code04 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm | m | 31139.0 | 31139.0 | 0.04 | False | None | None | False | None | False | 1245.56 | 0 | 4086365 | 159098 | None | code05 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | Each | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 | 4086366 | 159098 | None | code06 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg | No | 743.0 | 743.0 | 1.0 | False | None | None | False | None | False | 743.0 | 0 | 4086367 | 159098 | None | code07 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 676.0 | 676.0 | 1.0 | False | None | None | False | None | False | 676.0 | 0 | 4086368 | 159098 | None | code08 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 310.0 | 310.0 | 1.0 | False | None | None | False | None | False | 310.0 | 0 | 4086369 | 159098 | None | code09 | Supplying & fixing of Porcela in fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | Each | 691.0 | 691.0 | 6.0 | False | None | None | False | None | False | 4146.0 | 0 | 4086370 | 159098 | None | code10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phaseseparators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA | Each | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 | 4086371 | 159098 | None | code11 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG 900x400x200 900x450x2 sides 900x200x4 sides 450x200x4 sides | Sqm | 0.5 | 0.5 | 18900.0 | False | None | None | False | None | False | 9450.0 | 0 | 4086372 | 159098 | None | code12 | Supplying.........A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips | m | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 | 4086373 | 159098 | None | code13 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron..and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 305.0 | 305.0 | 4.0 | False | None | None | False | None | False | 1220.0 | 0 | 4086374 | 159098 | None | code14 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x10 Sqm | m | 280.0 | 280.0 | 24.0 | False | None | None | False | None | False | 6720.0 | 0 | 4086375 | 159098 | None | code15 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner). | Cum | 1157.0 | 1157.0 | 7.2 | False | None | None | False | None | False | 8330.4 | 0 | 4086376 | 159098 | None | code16 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 262.0 | 262.0 | 28.8 | False | None | None | False | None | False | 7545.6 | 0 | 4086377 | 159098 | None | code17 | Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 331.0 | 331.0 | 12.0 | False | None | None | False | None | False | 3972.0 | 0 | 4086378 | 159098 | None | code18 | Dewatering Pump 10 HP | Hour | 230.0 | 230.0 | 16.0 | False | None | None | False | None | False | 3680.0 | 0 | 4086379 | 159098 | None | code19 | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing) Note: a) No Negative tolerance in respect of thickness is pemissible. b) Basic Cost of MS Plate is considered as Rs.68,200.00 per MT. The bare pipe cost worked out is Rs. 77.59/kg weight/m of pipe c) The pipe costs are FOR destination anywhere in Karnataka.For MS Pipes of 219mm dia: Pipe of 323.9mm dia -6.4mm thick | m | 6576.0 | 6576.0 | 6.2 | False | None | None | False | None | False | 40771.2 | 0 | 4086380 | 159098 | None | code20 | Pipe of 457mm dia-7.1mm thick | m | 10031.0 | 10031.0 | 5.1 | False | None | None | False | None | False | 51158.1 | 0 | 4086381 | 159098 | None | code21 | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with Each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing for: Note: 1) For small works where the C.M. lining is not practicable for inside surface of the pipe, food grade expoxy painting of two coat over one coat of epoxy primer may be proposed and got approved. 2) The above rates are applicable only for pipe works etc. complete 300 mm dia 90 degree bend - 2 Nos 2x3.142x0.008x0.316x0.70x7850=87.29 Kg | Kg | 170.0 | 170.0 | 87.29 | False | None | None | False | None | False | 14839.3 | 0 | 4086382 | 159098 | None | code22 | Tee: 300x300 mm dia - 2 Nos 2x3.142x0.008x0.316x0.70x7850=87.29 Kg | Kg | 170.0 | 170.0 | 87.29 | False | None | None | False | None | False | 14839.3 | 0 | 4086383 | 159098 | None | code23 | Reducer: 450x300 mm dia - 2 Nos 2x3.142x0.008x0.416x0.70x7850=114.91 Kg | Kg | 170.0 | 170.0 | 114.91 | False | None | None | False | None | False | 19534.7 | 0 | 4086384 | 159098 | None | code24 | Providing, fabricating, supplying and fixing at site various diameter MS MJ ends to suit CI / DI pipe as per the sketch . The cost is inclusive of all materials, i.e, rubber ‘O’ rings, flanges, bolts and nuts, consumables, hire charges, tools and tackles, welding equipments, lead and lifts, etc. complete as per the instructions of Engineer in charge 450 mm dia MS MJ end . | No | 7542.0 | 7542.0 | 1.0 | False | None | None | False | None | False | 7542.0 | 0 | 4086385 | 159098 | None | code25 | Providing Ductile Iron Push on special confirming to IS 9523:2000 - All D.I. Flanged MJ COLLAR 300 mm dia MJ Collar | No | 8449.0 | 8449.0 | 1.0 | False | None | None | False | None | False | 8449.0 | 0 | 4086386 | 159098 | None | code26 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN 16.0 and 300mm | No | 70444.0 | 70444.0 | 2.0 | False | None | None | False | None | False | 140888.0 | 0 | 4086387 | 159098 | None | code27 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. PCC-7.0x2.40x0.10= 1.68 cum | Cum | 6243.0 | 6243.0 | 1.68 | False | None | None | False | None | False | 10488.24 | 0 | 4086388 | 159098 | None | code28 | RCC-Bottom Slab-7.0x2.30x0.30=4.83 cum | Cum | 6243.0 | 6243.0 | 4.83 | False | None | None | False | None | False | 30153.69 | 0 | 4086389 | 159098 | None | code29 | RCC Side Wall-1x2x7.0x0.30x1.4=5.88 cum | Cum | 6243.0 | 6243.0 | 5.88 | False | None | None | False | None | False | 36708.84 | 0 | 4086390 | 159098 | None | code30 | RCC Side Wall-1x2x2.3x0.30x1.4=1.03 cum | Cum | 6243.0 | 6243.0 | 1.03 | False | None | None | False | None | False | 6430.29 | 0 | 4086391 | 159098 | None | code31 | Top Slab-7.0x2.30x0.30=4.83 cum | Cum | 6243.0 | 6243.0 | 4.83 | False | None | None | False | None | False | 30153.69 | 0 | 4086392 | 159098 | None | code32 | Percentage Additionalities for Formwork, Centering & Scaffolding RCC Roof Slabs (PCC, Bottom Slab,Wall & Top Slab) | Cum | 6243.0 | 6243.0 | 9.125 | False | None | None | False | None | False | 56967.375 | 0 | 4086393 | 159098 | None | code33 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificatio All other type of structures | t | 79011.0 | 79011.0 | 1.8 | False | None | None | False | None | False | 142219.8 | 0 | 4086394 | 159098 | None | code34 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 160.0 | 160.0 | 15.8 | False | None | None | False | None | False | 2528.0 | 0 | 4086395 | 159098 | None | code35 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. Distance of 4 to 5 KM | Cum | 85.0 | 85.0 | 32.2 | False | None | None | False | None | False | 2737.0 | 0 |
|