1727350047000 | 0 | None | None | Buildings | Construction of rest rooms for PKS working in Tumkur City Corporation | 1689521.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4085890 | 159071 | None | dma01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 120.0 | False | None | None | False | None | False | 12852.0 | 0 | 4085891 | 159071 | None | dma02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1 | Cum | 5947.2 | 5947.2 | 13.2 | False | None | None | False | None | False | 78503.04 | 0 | 4085892 | 159071 | None | dma03 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 | Cum | 7348.32 | 7348.32 | 10.99 | False | None | None | False | None | False | 80758.0368 | 0 | 4085893 | 159071 | None | dma04 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing andtechnical specification. | Tonne | 93929.85 | 93929.85 | 0.4813 | False | None | None | False | None | False | 45208.436805 | 0 | 4085894 | 159071 | None | dma05 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 | No | 9450.0 | 9450.0 | 4.0 | False | None | None | False | None | False | 37800.0 | 0 | 4085895 | 159071 | None | dma06 | GI Sheet Portable Restroom with Washroom for Cabins 20’x10’x8.5 1. Bottom Frame C Channel/100x50 Squire PipeISI Marked
2. Stiffener Bottom C Channel 80x40mm & 50x50mm square pipes. ISI Marked
3. Top Frame Frame made of 50x50mm square pipes. ISI Marked
4. Stiffener Top 25x50 mm &20x40 mm Square pipes. ISI Marked
5. Sidewall Stiffeners Corners shall be of 75x75 mm L Angle & wall thickness of 50 mm. ISI Marked
6. Paneling Outside Specially corrugated G.I sheet welded on M.S. frame. ISI Marked
7. Roof Outside G.I sheet properly sloped & water tight. ISI Marked
8. Bottom Flooring
On the bottom frame 18 mm Birla Air con thick Cement Board fiber sheets
shall be fixed by means of self-taping screw & PVC vinyl Carpet shall be fixed on
the panel. (100% water, termite & dimensional proof with vinyl Carpet)
9. Door
The door shall be of external opening type made out of the same material as
wall panels. Frame work by tubular pipe of 25x25 mm& the door interior shall
be finished with same material matching with that of the Cabin interior. Door
with std L Drop & handles.
10. Aluminum Sliding
Window
Double Shutter Aluminum Window With Blue Rays Glass
11. Insulation Glass wool with insulation for top side walls Foam.
12. Wiring
All wiring shall be concealed and shall be PVC insulated copper wires of ISI
quality, suitable for 240 volt.
Light, Fan -1.5mm Thick cable
Socket, AC -2.5 mm Thick cable
Main Supply -4mm Thick cable
13. Outside Painting All components are painted with a coat of primer & 2 coats of corrosion free
paint i.e. Synthetic Enamel paint. Standard features to be included Aluminum Main Door With Lock
Aluminium Toilet entry door
01)Main Door With Lock
Aluminium Toilet entry door and separate paryion door inside with aluminum partion
2) Aluminum Sliding Window 4’x3’ with MS Grill 03
3) Paneling on all MDF Board As per Size.
Wall paneling As per Size.
4) Wall to Wall Vinyl flooring. As per Size.
5) Electrical Fittings
a) Tube lights 05
b) Cabin GRC Fan 02
c) External bulk head light 01
d) Electrical switch boards inside 05
e) 6 Amp Switch and Socket 10
f) 16 Amp Switch & Socket 01
g) Main Switch outside container (32 Amp MCB with Single
face wiring)
6)including all electric work and plumbing work connecting to near by ugd line and water source connected by near by water source with 1000li tank
14. Lifting Hooks Specially formed for easy lift & shift. | Unit | 358600.0 | 358600.0 | 4.0 | False | None | None | False | None | False | 1434400.0 | 0 |
|