1727328610000 | 0 | None | None | Buildings | Construction of New Building to Assistant Fishery Director Office in Periyapaptna Town | 1777873.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4078441 | 158727 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(P.No.8 /I.No. 1.12 of CSR 2023-24, Volume-I) | Cum | 95.0 | 95.0 | 90.0 | False | None | None | False | None | False | 8550.0 | 0 | 4078442 | 158727 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ( P.NO. 8, I.No. 1.14.1,Volume No-1)2023-24 | Cum | 102.0 | 102.0 | 73.4 | False | None | None | False | None | False | 7486.8 | 0 | 4078443 | 158727 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to omplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:5:10 (M10) Using 40 mm nominal size graded crushed coarse aggregates (P.No.15, I.No.2.1.1) (Volume No-1) 2023-24 | Cum | 5338.0 | 5338.0 | 12.05 | False | None | None | False | None | False | 64322.9 | 0 | 4078444 | 158727 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (P.No.9, I.No. 5.1.1 of PWD SR 2023-24, Volume-II) | Cum | 5611.0 | 5611.0 | 13.23 | False | None | None | False | None | False | 74233.53 | 0 | 4078445 | 158727 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(P.No.9, I.No. 5.3 of PWD SR 2021-22, Volume-II) | Cum | 6205.0 | 6205.0 | 5.13 | False | None | None | False | None | False | 31831.65 | 0 | 4078446 | 158727 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(P.No.7 /I.No. 1.9 of CSR 2022-23, Volume-I, Chapter-01) | Cum | 266.0 | 266.0 | 38.9025 | False | None | None | False | None | False | 10348.065 | 0 | 4078447 | 158727 | None | code07 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(P.No.44 /I.No. 8.19.1 of CSR 2021-22, Volume-II) | Cum | 255.0 | 255.0 | 12.15 | False | None | None | False | None | False | 3098.25 | 0 | 4078448 | 158727 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Footing | Cum | 6829.0 | 6829.0 | 7.77 | False | None | None | False | None | False | 53061.33 | 0 | 4078449 | 158727 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Columns | Cum | 11271.0 | 11271.0 | 3.09 | False | None | None | False | None | False | 34827.39 | 0 | 4078450 | 158727 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(P.No.14, I.No. 6.8 of PWD SR 2023-24, Volume-II) | Cum | 7969.0 | 7969.0 | 39.27 | False | None | None | False | None | False | 312942.63 | 0 | 4078451 | 158727 | None | Code16 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No.41, I.No. 8.4.1 of PWD SR 2023-24, Volume-II) | Sqm | 323.0 | 323.0 | 86.45 | False | None | None | False | None | False | 27923.35 | 0 | 4078452 | 158727 | None | code17 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No.42, I.No. 8.7 of PWD SR 2023-24, Volume-II) | Sqm | 366.0 | 366.0 | 338.85 | False | None | None | False | None | False | 124019.1 | 0 | 4078453 | 158727 | None | code18 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.42, I.No. 8.8 of PWD SR 2023-24, Volume -II, Chapter-08)) | Sqm | 371.0 | 371.0 | 152.97 | False | None | None | False | None | False | 56751.87 | 0 | 4078454 | 158727 | None | code19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(P.No.60, I.No. 9.12.2 of PWD SR 2023-24, Volume -II, Chapter-09) Size of Tile 600x600 mm | Sqm | 1145.0 | 1145.0 | 75.02 | False | None | None | False | None | False | 85897.9 | 0 | 4078455 | 158727 | None | code20 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(P.No.60, I.No. 9.11 of PWD SR 2023-24, Volume -II) | Sqm | 889.0 | 889.0 | 8.8 | False | None | None | False | None | False | 7823.2 | 0 | 4078456 | 158727 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (P.No.85, I.No.11.34B Volume-2) | Kgs | 183.0 | 183.0 | 241.92 | False | None | None | False | None | False | 44271.36 | 0 | 4078457 | 158727 | None | code22 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.89, I.No.11.37.1Volume-2) | Sqm | 988.0 | 988.0 | 12.06 | False | None | None | False | None | False | 11915.28 | 0 | 4078458 | 158727 | None | code23 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (P.No.99, I.No.12.12.1Volume-2) | Cum | 124202.0 | 124202.0 | 0.29 | False | None | None | False | None | False | 36018.58 | 0 | 4078459 | 158727 | None | code24 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (P.No.104, I.No.12.54 Volume-2) | Mtr | 318.0 | 318.0 | 12.4 | False | None | None | False | None | False | 3943.2 | 0 | 4078460 | 158727 | None | code25 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thic PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (P.No.104, I.No.12.55 Volume-2) | Sqm | 2366.0 | 2366.0 | 3.57 | False | None | None | False | None | False | 8446.62 | 0 | 4078461 | 158727 | None | code26 | Painting Steel work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.47, I.No. 8.33.3 Volume-2) | Sqm | 139.0 | 139.0 | 28.08 | False | None | None | False | None | False | 3903.12 | 0 | 4078462 | 158727 | None | code27 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46, I.No. 8.33.2 Volume-2) | Sqm | 138.0 | 138.0 | 0.88 | False | None | None | False | None | False | 121.44 | 0 | 4078463 | 158727 | None | code28 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.45, I.No. 8.25, of PWD SR 2023-24, Volume -II, Chapter-08) | Sqm | 137.0 | 137.0 | 425.3 | False | None | None | False | None | False | 58266.1 | 0 | 4078464 | 158727 | None | code29 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.45, I.No. 8.29, of PWD SR 2023-24, Volume -II, Chapter-08). | Sqm | 283.0 | 283.0 | 152.97 | False | None | None | False | None | False | 43290.51 | 0 | 4078465 | 158727 | None | code30 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: (P.No.113, I.No. 10.1.7, of PWD SR 2023-24, Volume-5). PVC pipes 110mm dia., 6 kg/sqcm & class 3, 110mm dia | Rmtr | 411.0 | 411.0 | 14.0 | False | None | None | False | None | False | 5754.0 | 0 | 4078466 | 158727 | None | code31 | KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure 25mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 (P.No.96, I.No.13.76) | Rmtr | 200.0 | 200.0 | 15.0 | False | None | None | False | None | False | 3000.0 | 0 | 4078467 | 158727 | None | code32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(For 1000 litre capacity) | Ltr | 9.0 | 9.0 | 1000.0 | False | None | None | False | None | False | 9000.0 | 0 | 4078468 | 158727 | None | code33 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.125, I.No.14.7 (A) Volume-2) | Each | 2866.0 | 2866.0 | 1.0 | False | None | None | False | None | False | 2866.0 | 0 | 4078469 | 158727 | None | code34 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe (P.No.128, I.No.14.28.1 Volume-2) | Each | 76.0 | 76.0 | 1.0 | False | None | None | False | None | False | 76.0 | 0 | 4078470 | 158727 | None | code35 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.115, I.No.13.2.1 Volume-2) | Each | 286.0 | 286.0 | 2.0 | False | None | None | False | None | False | 572.0 | 0 | 4078471 | 158727 | None | code36 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore (P.No.115, I.No.13.5.1 Volume-2) | Each | 296.0 | 296.0 | 2.0 | False | None | None | False | None | False | 592.0 | 0 | 4078472 | 158727 | None | code37 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore (P.No.115, I.No.13.6.1 Volume-2) | Each | 620.0 | 620.0 | 2.0 | False | None | None | False | None | False | 1240.0 | 0 | 4078473 | 158727 | None | code38 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (P.No.131, I.No.14.3.1 Volume-2) | Each | 5977.0 | 5977.0 | 2.0 | False | None | None | False | None | False | 11954.0 | 0 | 4078474 | 158727 | None | code39 | KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure 25mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 (P.No.96, I.No.13.76) | Rmtr | 200.0 | 200.0 | 30.0 | False | None | None | False | None | False | 6000.0 | 0 | 4078475 | 158727 | None | code40 | Supplying heavy guage PVC pipe 25 mm Dia 2 mm thick confirming to IS-2509 with suitable size bends, junction box, adhesive paste etc and fixing using inverted wood plug in case RCC ceiling & RCC Wall stone Structure are rawal plugs in case of brick walls and cement plastering damaged portion using heavy gaauge saddles at an intervel of 700mm using NF Screws (2/1) (V-6, pg.no 2, I.No 1.1.2) | Mtr | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 | 4078476 | 158727 | None | code41 | Supplying and fixing Metal fan Box with Round Hook (V-6, pg.no 4, I.No 1.13) | Nos | 117.0 | 117.0 | 4.0 | False | None | None | False | None | False | 468.0 | 0 | 4078477 | 158727 | None | code42 | Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall (a)1-3Way (V-6, pg.no 8, I.No 3.4.2) | Each | 159.0 | 159.0 | 7.0 | False | None | None | False | None | False | 1113.0 | 0 | 4078478 | 158727 | None | code43 | Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall b)10-12 Way | Each | 328.57 | 328.57 | 8.0 | False | None | None | False | None | False | 2628.56 | 0 | 4078479 | 158727 | None | code44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (V-6, pg.no 8, I.No 3.5.2 &3.5.6) (a) 3 Module | Each | 161.0 | 161.0 | 7.0 | False | None | None | False | None | False | 1127.0 | 0 | 4078480 | 158727 | None | code45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (V-6, pg.no 8, I.No 3.5.2 (b)10-12 Module | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 | 4078481 | 158727 | None | code46 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch Short point upto 3Mtr from tapping point to out let via switch(V-6, pg.no 5, I.No 2.1.1) a)Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 14.0 | False | None | None | False | None | False | 3990.0 | 0 | 4078482 | 158727 | None | code47 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch Short point upto 3Mtr from tapping point to out let via switch(V-6, pg.no 5, I.No 2.1.1) b) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch t (P.No.5, I.No. 2.1.2) | Point | 394.0 | 394.0 | 20.0 | False | None | None | False | None | False | 7880.0 | 0 | 4078483 | 158727 | None | code48 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) a) 1 mm2 | Mtr | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 | 4078484 | 158727 | None | code49 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) (b) 1.50Sqmm (P.No.5 I.No. 2.3.2) | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 | 4078485 | 158727 | None | code50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) c) 2.50 Sqmm (P.No.5 I.No. 2.3.2) | Mtr | 42.0 | 42.0 | 100.0 | False | None | None | False | None | False | 4200.0 | 0 | 4078486 | 158727 | None | code51 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (a) 6A One Way Switch | Each | 102.0 | 102.0 | 20.0 | False | None | None | False | None | False | 2040.0 | 0 | 4078487 | 158727 | None | code52 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (b) 6 Two Way Switch (P.No.9, I.No.3.6.2) | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 | 4078488 | 158727 | None | code53 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (c) 6 Three Way Switch (P.No.9, I.No.3.6.3) | Each | 171.0 | 171.0 | 3.0 | False | None | None | False | None | False | 513.0 | 0 | 4078489 | 158727 | None | code54 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (d) Stepped Fan regulator Two Module (P.No.9, I.No.3.6.4) | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 4078490 | 158727 | None | code55 | Supplying and fixing LED Bulk head of 10 W with IP-65 Protection and IK-08 Impact resistance suitable for surfacew and wall mounting application (P.No.46, I.No.11.15) | Each | 842.0 | 842.0 | 2.0 | False | None | None | False | None | False | 1684.0 | 0 | 4078491 | 158727 | None | code56 | Supplying of . feet - LED Batten. W with high quality diffuser with life of 25000 burning hours and 70% lumen maintenance with CRI 80 power input 220-240V @ 50Hz and Power factor 0.90 along with CE approved 2years warranty against any manufactureing defect working under standard electrical condition LED Light fitting 1X4' 20/22W (P.No.43, I.No.11.3.2) | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 4078492 | 158727 | None | code57 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model(P.No.30, I.No.6.3.1) | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 4078493 | 158727 | None | code58 | Fixing a ceiling/ wall mounting fan of all capacities and all types necessary clamps and S hook made out of 165mm dia MS rod, with 5 Amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring (P.No. 57 I.No. 13.10) | Each | 171.0 | 171.0 | 3.0 | False | None | None | False | None | False | 513.0 | 0 | 4078494 | 158727 | None | code59 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. single door 4 Way SP & N (P.No.18, I.No.5.19.1) | Each | 1241.0 | 1241.0 | 2.0 | False | None | None | False | None | False | 2482.0 | 0 | 4078495 | 158727 | None | code60 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP(P.No.17, I.No.5.18.4) | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 4078496 | 158727 | None | code61 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG P.No. 20, I.No.5.42.2) | Sq CM | 0.5 | 0.5 | 8000.0 | False | None | None | False | None | False | 4000.0 | 0 | 4078497 | 158727 | None | code62 | Supplying fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single pahase class-1 Accuracy with Temper Proof Energy Meter(P.No.19, I.No.5.30) | Each | 1380.0 | 1380.0 | 2.0 | False | None | None | False | None | False | 2760.0 | 0 | 4078498 | 158727 | None | code63 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/pannel using necessary nuts bolts and washers (a) 32Amps (P.No.14, I.No.5.7.1) | Each | 157.0 | 157.0 | 2.0 | False | None | None | False | None | False | 314.0 | 0 | 4078499 | 158727 | None | code64 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( PWD ELE SR 2019-20 P.No. 40 I.No. 6.4.6) | Mtr | 81.0 | 81.0 | 50.0 | False | None | None | False | None | False | 4050.0 | 0 | 4078500 | 158727 | None | code65 | Earth work excavation for cable trench of 0.5 to 075mtr width and depth upto 1.00mtr including trial pit depositing on bank upto a lead of 50mtr Supplying and dispalying necessary Danger board and lighting using sit rails and sign boards at every 100 mtrs wherever necessary In Ordinary soil | Cum | 260.0 | 260.0 | 20.0 | False | None | None | False | None | False | 5200.0 | 0 | 4078501 | 158727 | None | code66 | Labour charges for laying of 1.1KV class UG cable when supplied agency in existing trench GI pipe / stone ware pipe on wall on pole as required in existing trench duct 6 sqm to 16sqm(P.No.174, I.No.21.05) existing trench | Mtr | 21.5 | 21.5 | 70.0 | False | None | None | False | None | False | 1505.0 | 0 | 4078502 | 158727 | None | code67 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers.(P.No.70, I.No.7.22) | Mtr | 20.09 | 20.09 | 20.0 | False | None | None | False | None | False | 401.8 | 0 | 4078503 | 158727 | None | code68 | Supplying fixing and wiring earth electrodes for grounding conduit I.C cutouts and other equipments on the ,meter board using 40mm dia 2.90mm thick GI pipes 2.50m long birred in pit, the pit should be filled with equal proportion of charcoal and salt 150mm all-round the pipe to complete depth. The connection from the pipe to the conduct etc ., is to be established through GI wire of size as per IS specification 7.3.3 of IS732 using 12mm dia bolts , nuts, washers and check nuts etc., the pipe shell have 16 through holes of 12mm dia.(P.No.54, I.No.12.56) | No | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 | 4078504 | 158727 | None | code69 | KEB Deposit | Each | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 | 4078505 | 158727 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Plinth Beam | Cum | 9945.0 | 9945.0 | 4.56 | False | None | None | False | None | False | 45349.2 | 0 | 4078506 | 158727 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Lintel L/W | Cum | 10608.0 | 10608.0 | 2.22 | False | None | None | False | None | False | 23549.76 | 0 | 4078507 | 158727 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Roof Beams | Cum | 10608.0 | 10608.0 | 5.82 | False | None | None | False | None | False | 61738.56 | 0 | 4078508 | 158727 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Roof slab | Cum | 9945.0 | 9945.0 | 15.65 | False | None | None | False | None | False | 155639.25 | 0 | 4078509 | 158727 | None | code14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) (P.No.18, I.No. 2.11a, Volume No-2) 2023-24 | Tonne | 89457.0 | 89457.0 | 2.76 | False | None | None | False | None | False | 246901.32 | 0 |
|