createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727328609952
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee530.00
emd52500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-10-2024 16:30:00
tenderQueryClose03-10-2024 16:30:00
technicalBidOpen07-10-2024 17:00:00
publishedDate26-09-2024 16:26:19
publishedByPostRDPR_EE_DIV_KRN
publishedByUserKPE18448 - S LAKSHMIKANTH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonDhanalakshmi K S
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9972961399
tenderSupplierListNone
tenderSchedule
createdTs1727328610001
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8609
titleConstruction of New Building to Assistant Fishery Director Office in Periyapaptna Town
descriptionConstruction of New Building to Assistant Fishery Director Office in Periyapaptna Town
categoryWORKS
categoryTextWorks
ecv2100000.00
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location974
locationNameRDPR Division Office K R Nagara
provisionalAmount2100000.0
groupOverheadTotal322126.38
fileNumberRDPR-FISHERY/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17273286100000NoneNoneBuildingsConstruction of New Building to Assistant Fishery Director Office in Periyapaptna Town1777873.62
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4078441158727Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(P.No.8 /I.No. 1.12 of CSR 2023-24, Volume-I)Cum95.095.090.0FalseNoneNoneFalseNoneFalse8550.00
4078442158727Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ( P.NO. 8, I.No. 1.14.1,Volume No-1)2023-24Cum102.0102.073.4FalseNoneNoneFalseNoneFalse7486.80
4078443158727Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to omplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:5:10 (M10) Using 40 mm nominal size graded crushed coarse aggregates (P.No.15, I.No.2.1.1) (Volume No-1) 2023-24Cum5338.05338.012.05FalseNoneNoneFalseNoneFalse64322.90
4078444158727Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (P.No.9, I.No. 5.1.1 of PWD SR 2023-24, Volume-II)Cum5611.05611.013.23FalseNoneNoneFalseNoneFalse74233.530
4078445158727Nonecode05Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(P.No.9, I.No. 5.3 of PWD SR 2021-22, Volume-II)Cum6205.06205.05.13FalseNoneNoneFalseNoneFalse31831.650
4078446158727Nonecode06Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(P.No.7 /I.No. 1.9 of CSR 2022-23, Volume-I, Chapter-01)Cum266.0266.038.9025FalseNoneNoneFalseNoneFalse10348.0650
4078447158727Nonecode07Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(P.No.44 /I.No. 8.19.1 of CSR 2021-22, Volume-II)Cum255.0255.012.15FalseNoneNoneFalseNoneFalse3098.250
4078448158727Nonecode08Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)FootingCum6829.06829.07.77FalseNoneNoneFalseNoneFalse53061.330
4078449158727Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)ColumnsCum11271.011271.03.09FalseNoneNoneFalseNoneFalse34827.390
4078450158727Nonecode15Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(P.No.14, I.No. 6.8 of PWD SR 2023-24, Volume-II)Cum7969.07969.039.27FalseNoneNoneFalseNoneFalse312942.630
4078451158727NoneCode16Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No.41, I.No. 8.4.1 of PWD SR 2023-24, Volume-II)Sqm323.0323.086.45FalseNoneNoneFalseNoneFalse27923.350
4078452158727Nonecode17Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No.42, I.No. 8.7 of PWD SR 2023-24, Volume-II)Sqm366.0366.0338.85FalseNoneNoneFalseNoneFalse124019.10
4078453158727Nonecode18Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.42, I.No. 8.8 of PWD SR 2023-24, Volume -II, Chapter-08))Sqm371.0371.0152.97FalseNoneNoneFalseNoneFalse56751.870
4078454158727Nonecode19Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(P.No.60, I.No. 9.12.2 of PWD SR 2023-24, Volume -II, Chapter-09) Size of Tile 600x600 mmSqm1145.01145.075.02FalseNoneNoneFalseNoneFalse85897.90
4078455158727Nonecode20Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(P.No.60, I.No. 9.11 of PWD SR 2023-24, Volume -II)Sqm889.0889.08.8FalseNoneNoneFalseNoneFalse7823.20
4078456158727Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (P.No.85, I.No.11.34B Volume-2)Kgs183.0183.0241.92FalseNoneNoneFalseNoneFalse44271.360
4078457158727Nonecode22Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.89, I.No.11.37.1Volume-2)Sqm988.0988.012.06FalseNoneNoneFalseNoneFalse11915.280
4078458158727Nonecode23Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (P.No.99, I.No.12.12.1Volume-2)Cum124202.0124202.00.29FalseNoneNoneFalseNoneFalse36018.580
4078459158727Nonecode24Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (P.No.104, I.No.12.54 Volume-2)Mtr318.0318.012.4FalseNoneNoneFalseNoneFalse3943.20
4078460158727Nonecode25Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thic PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (P.No.104, I.No.12.55 Volume-2)Sqm2366.02366.03.57FalseNoneNoneFalseNoneFalse8446.620
4078461158727Nonecode26Painting Steel work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.47, I.No. 8.33.3 Volume-2)Sqm139.0139.028.08FalseNoneNoneFalseNoneFalse3903.120
4078462158727Nonecode27Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46, I.No. 8.33.2 Volume-2)Sqm138.0138.00.88FalseNoneNoneFalseNoneFalse121.440
4078463158727Nonecode28Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.45, I.No. 8.25, of PWD SR 2023-24, Volume -II, Chapter-08)Sqm137.0137.0425.3FalseNoneNoneFalseNoneFalse58266.10
4078464158727Nonecode29Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.45, I.No. 8.29, of PWD SR 2023-24, Volume -II, Chapter-08).Sqm283.0283.0152.97FalseNoneNoneFalseNoneFalse43290.510
4078465158727Nonecode30Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: (P.No.113, I.No. 10.1.7, of PWD SR 2023-24, Volume-5). PVC pipes 110mm dia., 6 kg/sqcm & class 3, 110mm diaRmtr411.0411.014.0FalseNoneNoneFalseNoneFalse5754.00
4078466158727Nonecode31KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure 25mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 (P.No.96, I.No.13.76)Rmtr200.0200.015.0FalseNoneNoneFalseNoneFalse3000.00
4078467158727Nonecode32Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(For 1000 litre capacity)Ltr9.09.01000.0FalseNoneNoneFalseNoneFalse9000.00
4078468158727Nonecode33Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.125, I.No.14.7 (A) Volume-2)Each2866.02866.01.0FalseNoneNoneFalseNoneFalse2866.00
4078469158727Nonecode34Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe (P.No.128, I.No.14.28.1 Volume-2)Each76.076.01.0FalseNoneNoneFalseNoneFalse76.00
4078470158727Nonecode35Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.115, I.No.13.2.1 Volume-2)Each286.0286.02.0FalseNoneNoneFalseNoneFalse572.00
4078471158727Nonecode36Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore (P.No.115, I.No.13.5.1 Volume-2)Each296.0296.02.0FalseNoneNoneFalseNoneFalse592.00
4078472158727Nonecode37Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore (P.No.115, I.No.13.6.1 Volume-2)Each620.0620.02.0FalseNoneNoneFalseNoneFalse1240.00
4078473158727Nonecode38Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (P.No.131, I.No.14.3.1 Volume-2)Each5977.05977.02.0FalseNoneNoneFalseNoneFalse11954.00
4078474158727Nonecode39KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure 25mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 (P.No.96, I.No.13.76)Rmtr200.0200.030.0FalseNoneNoneFalseNoneFalse6000.00
4078475158727Nonecode40Supplying heavy guage PVC pipe 25 mm Dia 2 mm thick confirming to IS-2509 with suitable size bends, junction box, adhesive paste etc and fixing using inverted wood plug in case RCC ceiling & RCC Wall stone Structure are rawal plugs in case of brick walls and cement plastering damaged portion using heavy gaauge saddles at an intervel of 700mm using NF Screws (2/1) (V-6, pg.no 2, I.No 1.1.2)Mtr81.081.0100.0FalseNoneNoneFalseNoneFalse8100.00
4078476158727Nonecode41Supplying and fixing Metal fan Box with Round Hook (V-6, pg.no 4, I.No 1.13)Nos117.0117.04.0FalseNoneNoneFalseNoneFalse468.00
4078477158727Nonecode42Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall (a)1-3Way (V-6, pg.no 8, I.No 3.4.2)Each159.0159.07.0FalseNoneNoneFalseNoneFalse1113.00
4078478158727Nonecode43Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall b)10-12 WayEach328.57328.578.0FalseNoneNoneFalseNoneFalse2628.560
4078479158727Nonecode44Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (V-6, pg.no 8, I.No 3.5.2 &3.5.6) (a) 3 ModuleEach161.0161.07.0FalseNoneNoneFalseNoneFalse1127.00
4078480158727Nonecode45Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (V-6, pg.no 8, I.No 3.5.2 (b)10-12 ModuleEach344.0344.08.0FalseNoneNoneFalseNoneFalse2752.00
4078481158727Nonecode46Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch Short point upto 3Mtr from tapping point to out let via switch(V-6, pg.no 5, I.No 2.1.1) a)Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.014.0FalseNoneNoneFalseNoneFalse3990.00
4078482158727Nonecode47Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch Short point upto 3Mtr from tapping point to out let via switch(V-6, pg.no 5, I.No 2.1.1) b) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch t (P.No.5, I.No. 2.1.2)Point394.0394.020.0FalseNoneNoneFalseNoneFalse7880.00
4078483158727Nonecode48Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) a) 1 mm2Mtr19.019.0100.0FalseNoneNoneFalseNoneFalse1900.00
4078484158727Nonecode49Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) (b) 1.50Sqmm (P.No.5 I.No. 2.3.2)Mtr26.026.0100.0FalseNoneNoneFalseNoneFalse2600.00
4078485158727Nonecode50Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (V-6, pg.no 8, I.No 2.3.1) c) 2.50 Sqmm (P.No.5 I.No. 2.3.2)Mtr42.042.0100.0FalseNoneNoneFalseNoneFalse4200.00
4078486158727Nonecode51Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (a) 6A One Way SwitchEach102.0102.020.0FalseNoneNoneFalseNoneFalse2040.00
4078487158727Nonecode52Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (b) 6 Two Way Switch (P.No.9, I.No.3.6.2)Each166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
4078488158727Nonecode53Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (c) 6 Three Way Switch (P.No.9, I.No.3.6.3)Each171.0171.03.0FalseNoneNoneFalseNoneFalse513.00
4078489158727Nonecode54Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (d) Stepped Fan regulator Two Module (P.No.9, I.No.3.6.4)Each357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
4078490158727Nonecode55Supplying and fixing LED Bulk head of 10 W with IP-65 Protection and IK-08 Impact resistance suitable for surfacew and wall mounting application (P.No.46, I.No.11.15)Each842.0842.02.0FalseNoneNoneFalseNoneFalse1684.00
4078491158727Nonecode56Supplying of . feet - LED Batten. W with high quality diffuser with life of 25000 burning hours and 70% lumen maintenance with CRI 80 power input 220-240V @ 50Hz and Power factor 0.90 along with CE approved 2years warranty against any manufactureing defect working under standard electrical condition LED Light fitting 1X4' 20/22W (P.No.43, I.No.11.3.2)Each690.0690.010.0FalseNoneNoneFalseNoneFalse6900.00
4078492158727Nonecode57Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model(P.No.30, I.No.6.3.1)Each2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
4078493158727Nonecode58Fixing a ceiling/ wall mounting fan of all capacities and all types necessary clamps and S hook made out of 165mm dia MS rod, with 5 Amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring (P.No. 57 I.No. 13.10)Each171.0171.03.0FalseNoneNoneFalseNoneFalse513.00
4078494158727Nonecode59Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. single door 4 Way SP & N (P.No.18, I.No.5.19.1)Each1241.01241.02.0FalseNoneNoneFalseNoneFalse2482.00
4078495158727Nonecode60Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP(P.No.17, I.No.5.18.4)Each739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
4078496158727Nonecode61Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG P.No. 20, I.No.5.42.2)Sq CM0.50.58000.0FalseNoneNoneFalseNoneFalse4000.00
4078497158727Nonecode62Supplying fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single pahase class-1 Accuracy with Temper Proof Energy Meter(P.No.19, I.No.5.30)Each1380.01380.02.0FalseNoneNoneFalseNoneFalse2760.00
4078498158727Nonecode63Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/pannel using necessary nuts bolts and washers (a) 32Amps (P.No.14, I.No.5.7.1)Each157.0157.02.0FalseNoneNoneFalseNoneFalse314.00
4078499158727Nonecode64Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( PWD ELE SR 2019-20 P.No. 40 I.No. 6.4.6)Mtr81.081.050.0FalseNoneNoneFalseNoneFalse4050.00
4078500158727Nonecode65Earth work excavation for cable trench of 0.5 to 075mtr width and depth upto 1.00mtr including trial pit depositing on bank upto a lead of 50mtr Supplying and dispalying necessary Danger board and lighting using sit rails and sign boards at every 100 mtrs wherever necessary In Ordinary soilCum260.0260.020.0FalseNoneNoneFalseNoneFalse5200.00
4078501158727Nonecode66Labour charges for laying of 1.1KV class UG cable when supplied agency in existing trench GI pipe / stone ware pipe on wall on pole as required in existing trench duct 6 sqm to 16sqm(P.No.174, I.No.21.05) existing trenchMtr21.521.570.0FalseNoneNoneFalseNoneFalse1505.00
4078502158727Nonecode67Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers.(P.No.70, I.No.7.22)Mtr20.0920.0920.0FalseNoneNoneFalseNoneFalse401.80
4078503158727Nonecode68Supplying fixing and wiring earth electrodes for grounding conduit I.C cutouts and other equipments on the ,meter board using 40mm dia 2.90mm thick GI pipes 2.50m long birred in pit, the pit should be filled with equal proportion of charcoal and salt 150mm all-round the pipe to complete depth. The connection from the pipe to the conduct etc ., is to be established through GI wire of size as per IS specification 7.3.3 of IS732 using 12mm dia bolts , nuts, washers and check nuts etc., the pipe shell have 16 through holes of 12mm dia.(P.No.54, I.No.12.56)No3510.03510.02.0FalseNoneNoneFalseNoneFalse7020.00
4078504158727Nonecode69KEB DepositEach5000.05000.01.0FalseNoneNoneFalseNoneFalse5000.00
4078505158727Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Plinth BeamCum9945.09945.04.56FalseNoneNoneFalseNoneFalse45349.20
4078506158727Nonecode11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Lintel L/WCum10608.010608.02.22FalseNoneNoneFalseNoneFalse23549.760
4078507158727Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Roof BeamsCum10608.010608.05.82FalseNoneNoneFalseNoneFalse61738.560
4078508158727Nonecode13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.RCC M20 Design Mix for all Superstructure work (PNo.16/ INo.2.5.2)Roof slabCum9945.09945.015.65FalseNoneNoneFalseNoneFalse155639.250
4078509158727Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) (P.No.18, I.No. 2.11a, Volume No-2) 2023-24Tonne89457.089457.02.76FalseNoneNoneFalseNoneFalse246901.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17273286110000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17273286110000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17273286110000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17273286110000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17273286110000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17273286410000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17273286550000NoneNoneELIGIBILITYBanker Details Bidder shall pay Contract Management Module processing fees of 0.025 percent of the contact value (Min Rs.500/- and Max Rs.7500/-) soon after contract has been issued to bidder. The tender processing fee will not be refundableNone
17273286710000NoneNoneELIGIBILITYWithin 21 days of receipt of Letter of Acceptance, the successful Tenderer shall deliver to the employer a Security Deposit in the form of NSC/DD/ FDR in favour of the Executive Engineer, P.R.E. Division, K R Nagar, for an amount equivalent to 5 percent of the Contract price plus additional security for unbalanced tenders in accordance with the conditions of contract for General Category. .None
17273286870000NoneNoneELIGIBILITYAs per Karnataka State Government order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/ BMS/2007 Dated 27-7-2007, a sum amounting to 1% of the bill amount will be deducted towards Construction Labour Welfare fund. The tenderer shall abide by the directions of Government towards recovery as modifed by the Government from time to time .None
17273286990000NoneNoneELIGIBILITYAll safety precautions, warnings, signs, deployment of security guards have to be ensured so that no un towards incident happens on account of negligence or any project activity .None
17273287120000NoneNoneELIGIBILITYAll materials required for the work, shall be procured by the tenderer himself and should be got tested by the Department quality control authorities at his own cost before use for the work. If employer wishes to engage third party inspecting agency for the said work, apart from the quality control authorities, then the contractor should cooperate with the third party for test .None
17273287230000NoneNoneELIGIBILITYIn the case of death of the contractor after executing the agreement/ commencement of the work, his legal heir, if is an eligible registered contractor and is willing, can execute and complete the work at the accepted tender rates in the same terms and condition of the contractor of the workNone
17273287350000NoneNoneELIGIBILITYThe tenderers are requested to abide instructions and conditions 2 of 33 KPPP-Portal contained in the Standard Tender Documents K/W-1 and further orders thereon .None
17273287470000NoneNoneELIGIBILITYSite investigation report. The tenderer before applying this tender has to visit the site along with Junior Engineer/Assistant Engineer/ Assistant Executive Engineer of Periyapatna sub-Division and submit feasibility report to know the nature of work and working condition.None
17273287610000NoneNoneELIGIBILITYThe tenderer are Requested to Refer this Notification For More Information And fallow The conditionNone
17273287780000NoneNoneELIGIBILITYGST Shall be Paid SeparatelyNone
17273288030000NoneNoneELIGIBILITYList of existing commitments and ongoing work .None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneWork Done Certificate Tenderer in his name should have satisfactorily completed as a prime contractor for at least one similar work for the KW 1 works of Sl. No.01 of this notification Constructions of Buildings. value not less than 50 percent Rs 10.50 Lakh of the amount put to tender in any one of the last five financial year period 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 should be obtained from not below the rank of Executive Engineer,Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAnnual turnover certificate in all classes of civil engineering construction works only for least five financial years i.e. 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 obtained from the Competent authority Charted Accountant/Auditor.The tenderer must have achieved in at last one financial years of Last Five Financial Years an annual financial turnover not less than The amount put to tender Rs 21.00 Lakhs. Certificate should be in the prescribed form as in KW1 Section 3 3.2aPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnual Turnover Certificate in all classes of Civil Engineering works only for last Five Financial years ie., 2019-20, 2020-21, 2021-22 ,2022-23,and 2023-24 Certified from Charted Accountant with compulsory UDI number Profit and Loss, balance sheet shall be enclosedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSubmission of K Form liquid assets /availability of credit facilities of not less than Rs 6.30 Lakhs Credit lines/ letter of credit certificates from Nationalized bank for meeting the fund requirement as per KW-1Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD Contractor Civil Registration Certificate class 4 and aboveOthersTechnical
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Work Done Certificate Tenderer in his name should have satisfactorily completed as a prime contractor for at least one similar work for the KW 1 works of Sl. No.01 of this notification Constructions of Buildings. value not less than 50 percent Rs 10.50 Lakh of the amount put to tender in any one of the last five financial year period 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 should be obtained from not below the rank of Executive Engineer,TrueTechnical Bid
Annual turnover certificate in all classes of civil engineering construction works only for least five financial years i.e. 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 obtained from the Competent authority Charted Accountant/Auditor.The tenderer must have achieved in at last one financial years of Last Five Financial Years an annual financial turnover not less than The amount put to tender Rs 21.00 Lakhs. Certificate should be in the prescribed form as in KW1 Section 3 3.2aTrueTechnical Bid
Submission of K Form liquid assets /availability of credit facilities of not less than Rs 6.30 Lakhs Credit lines/ letter of credit certificates from Nationalized bank for meeting the fund requirement as per KW-1TrueTechnical Bid
PWD Contractor Civil Registration Certificate class 4 and aboveTrueTechnical Bid
Annual Turnover Certificate in all classes of Civil Engineering works only for last Five Financial years ie., 2019-20, 2020-21, 2021-22 ,2022-23,and 2023-24 Certified from Charted Accountant with compulsory UDI number Profit and Loss, balance sheet shall be enclosedTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone