1727423904000 | 0 | None | None | Water supply/sewage lines | Construction of R.O plant near Basaweshawar temple in laxmi camp n ward no 07 IN BALAGANUR TP LIMIT. | 793534.3 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4093344 | 159410 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir draft,approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 5.76 | False | None | None | False | None | False | 2133.8496 | 0 | 4093345 | 159410 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7017.69 | 7017.69 | 0.96 | False | None | None | False | None | False | 6736.9824 | 0 | 4093346 | 159410 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basaltcrushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, includingall lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7834.19 | 7834.19 | 2.064 | False | None | None | False | None | False | 16169.76816 | 0 | 4093347 | 159410 | None | code04 | Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Cement Concrete Drain Walls 35% | Cum | 2741.96 | 2741.96 | 2.064 | False | None | None | False | None | False | 5659.40544 | 0 | 4093348 | 159410 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD CSR 2023-24, Vol-II, P. No. 9, I. No. 5.4 | Cum | 7915.97 | 7915.97 | 2.88 | False | None | None | False | None | False | 22797.9936 | 0 | 4093349 | 159410 | None | code06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings PWD CSR 2023-24, Vol-I, P. No. 18, I. No. 2.11a | Tonne | 110837.22 | 110837.22 | 0.103 | False | None | None | False | None | False | 11416.23366 | 0 | 4093350 | 159410 | None | code07 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1525.2 | 1525.2 | 31.945 | False | None | None | False | None | False | 48722.514 | 0 | 4093351 | 159410 | None | code08 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 168.5 | 168.5 | 59.36 | False | None | None | False | None | False | 10002.16 | 0 | 4093352 | 159410 | None | code09 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 1089.08 | 1089.08 | 16.0 | False | None | None | False | None | False | 17425.28 | 0 | 4093353 | 159410 | None | code10 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 KW 12 STG | Each | 17985.32 | 17985.32 | 1.0 | False | None | None | False | None | False | 17985.32 | 0 | 4093354 | 159410 | None | code11 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2 | Mtr | 167.26 | 167.26 | 50.0 | False | None | None | False | None | False | 8363.0 | 0 | 4093355 | 159410 | None | code12 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 4093356 | 159410 | None | code13 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. | Each | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 4093357 | 159410 | None | code14 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. | Mtr | 105.31 | 105.31 | 40.0 | False | None | None | False | None | False | 4212.4 | 0 | 4093358 | 159410 | None | code15 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Mtr | 681.45 | 681.45 | 30.0 | False | None | None | False | None | False | 20443.5 | 0 | 4093359 | 159410 | None | code16 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark | Set | 5575.5 | 5575.5 | 1.0 | False | None | None | False | None | False | 5575.5 | 0 | 4093360 | 159410 | None | code17 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1370.33 | 1370.33 | 11.9 | False | None | None | False | None | False | 16306.927 | 0 | 4093361 | 159410 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 72.87 | False | None | None | False | None | False | 14001.9705 | 0 | 4093362 | 159410 | None | code19 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping,product water tank on single phase power supply as per the encloseddetailed Technical Specifications including cost of material, loadingand unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to beinvited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components 1.1For 1000 LPH SS : Skid Type | Cum | 546399.0 | 546399.0 | 1.0 | False | None | None | False | None | False | 546399.0 | 0 | 4093363 | 159410 | None | code20 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 |
|