createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727352642870
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1060.00
emd84726.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-10-2024 16:00:00
tenderQueryClose03-10-2024 16:00:00
technicalBidOpen14-10-2024 16:00:00
publishedDate27-09-2024 13:02:26
publishedByPostUHS_EE_BGK
publishedByUserKPE13659 - VIJAYBHASKAR M BHAJANTRI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVijaybhaskar Bhajantri
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08354230251
mobileNumber9480696398
tenderSupplierListNone
tenderSchedule
createdTs1727352642903
version4
createdDateNone
modifiedDateNone
tenderNumberUHS/2024-25/BD/WORK_INDENT10
titleConstruction of Floriculture Incubation Centre for Dry Flower Making ( Under RKVY Project) at College of Horticulture Bengaluru
descriptionConstruction of Floriculture Incubation Centre for Dry Flower Making ( Under RKVY Project) at College of Horticulture Bengaluru
categoryWORKS
categoryTextWorks
ecv4236300.84
deptNameUniversity of Horticultural Sciences
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location6400
locationNameUniversity of Horticultural Sciences Bagalkote
provisionalAmount4236301.0
groupOverheadTotalNone
fileNumberUHSB/WORK/10/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17273526430000NoneNoneBuildingsConstruction of Floriculture Incubation Centre for Dry Flower Making ( Under RKVY Project) at College of Horticulture Bengaluru4236300.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4086684159117None001Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Sqm100.1100.165.0FalseNoneNoneFalseNoneFalse6506.50
4086685159117None002Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of buildings & bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum266.2266.2115.0FalseNoneNoneFalseNoneFalse30613.00
4086686159117None003Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) INCLUDING FORMWORK Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6230.46230.436.7FalseNoneNoneFalseNoneFalse228655.680
4086687159117None004Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.INCLUDING FORMWORK M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6915.76915.722.1FalseNoneNoneFalseNoneFalse152836.970
4086688159117None005Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. INCLUDING FORMWORK M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11824.0111824.017.0FalseNoneNoneFalseNoneFalse82768.070
4086689159117None006Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6825.56825.533.7FalseNoneNoneFalseNoneFalse230019.350
4086690159117None007Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne98402.798402.73.11FalseNoneNoneFalseNoneFalse306032.3970
4086691159117None008Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. INCLUDING FORMWORK M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10432.9510432.957.6FalseNoneNoneFalseNoneFalse79290.420
4086692159117None009Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.INCLUDING FORMWORK M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11668.811668.85.54FalseNoneNoneFalseNoneFalse64645.1520
4086693159117None010Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1441.01441.0263.1FalseNoneNoneFalseNoneFalse379127.10
4086694159117None011Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs124.3124.33260.0FalseNoneNoneFalseNoneFalse405218.00
4086695159117None012Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm624.8624.8327.0FalseNoneNoneFalseNoneFalse204309.60
4086696159117None013Providing and fixing aluminium sheet roofing accessories 0.60 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)Rmtr1181.41181.436.0FalseNoneNoneFalseNoneFalse42530.40
4086697159117None014Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.INCLUDING FORMWORKCum10027.7610027.762.0FalseNoneNoneFalseNoneFalse20055.520
4086698159117None015Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesINCLUDING FORMWORKCum6915.76915.716.0FalseNoneNoneFalseNoneFalse110651.20
4086699159117None016Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size - 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5929.05929.018.0FalseNoneNoneFalseNoneFalse106722.00
4086700159117None017Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6290.96290.97.5FalseNoneNoneFalseNoneFalse47181.750
4086701159117None018Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately)INCLUDING FORMWORK Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum6867.36867.311.2FalseNoneNoneFalseNoneFalse76913.760
4086702159117None019Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1214.41214.430.5FalseNoneNoneFalseNoneFalse37039.20
4086703159117None020Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm324.5324.5305.0FalseNoneNoneFalseNoneFalse98972.50
4086704159117None021Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.Sqm389.4389.4481.0FalseNoneNoneFalseNoneFalse187301.40
4086705159117None022Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum151881.4151881.40.08FalseNoneNoneFalseNoneFalse12150.5120
4086706159117None023Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Rmtr349.8349.818.3FalseNoneNoneFalseNoneFalse6401.340
4086707159117None024Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelamSqm2602.62602.65.7FalseNoneNoneFalseNoneFalse14834.820
4086708159117None025Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7793.57793.52.45FalseNoneNoneFalseNoneFalse19094.0750
4086709159117None026Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2896.32896.35.8FalseNoneNoneFalseNoneFalse16798.540
4086710159117None027Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an ven shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm171.6171.6305.0FalseNoneNoneFalseNoneFalse52338.00
4086711159117None028Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm191.4191.4481.0FalseNoneNoneFalseNoneFalse92063.40
4086712159117None029Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs184.8184.8576.0FalseNoneNoneFalseNoneFalse106444.80
4086713159117None030Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including one coat of primer ,preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm126.5126.5133.0FalseNoneNoneFalseNoneFalse16824.50
4086714159117None031Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm977.9977.914.0FalseNoneNoneFalseNoneFalse13690.60
4086715159117None032Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm1216.61216.658.0FalseNoneNoneFalseNoneFalse70562.80
4086716159117None033Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesRmtr416.9416.930.0FalseNoneNoneFalseNoneFalse12507.00
4086717159117None034Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia PipesRmtr238.7238.730.0FalseNoneNoneFalseNoneFalse7161.00
4086718159117None035Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia PipesRmtr409.2409.257.2FalseNoneNoneFalseNoneFalse23406.240
4086719159117None036Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia PipesRmtr524.7524.750.0FalseNoneNoneFalseNoneFalse26235.00
4086720159117None037Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.99.91000.0FalseNoneNoneFalseNoneFalse9900.00
4086721159117None038Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidNo.5321.85321.81.0FalseNoneNoneFalseNoneFalse5321.80
4086722159117None039Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsNo.5372.45372.41.0FalseNoneNoneFalseNoneFalse5372.40
4086723159117None040Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cisternNo.9506.29506.22.0FalseNoneNoneFalseNoneFalse19012.40
4086724159117None041Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tapsNo.3152.63152.62.0FalseNoneNoneFalseNoneFalse6305.20
4086725159117None042Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Class EconomyNo.1228.71228.76.0FalseNoneNoneFalseNoneFalse7372.20
4086726159117None043Providing and fixing Angle cock medium with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNo.1122.01122.05.0FalseNoneNoneFalseNoneFalse5610.00
4086727159117None044Providing and fixing Health faucetNo.715.0715.01.0FalseNoneNoneFalseNoneFalse715.00
4086728159117None045Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:No.2785.22785.22.0FalseNoneNoneFalseNoneFalse5570.40
4086729159117None046Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNo.242.0242.06.0FalseNoneNoneFalseNoneFalse1452.00
4086730159117None047Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common urnt clay (non modular) bricks of class designation 3.5No.6206.26206.23.0FalseNoneNoneFalseNoneFalse18618.60
4086731159117None048Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesRmtr317.9317.918.0FalseNoneNoneFalseNoneFalse5722.20
4086732159117None049Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 m nominal dia pipesRmtr423.5423.545.0FalseNoneNoneFalseNoneFalse19057.50
4086733159117None050Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum176.0176.0115.0FalseNoneNoneFalseNoneFalse20240.00
4086734159117None051Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum476.3476.3123.0FalseNoneNoneFalseNoneFalse58584.90
4086735159117None052Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal diaNo.45.145.16.0FalseNoneNoneFalseNoneFalse270.60
4086736159117None053Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick M 20 mix cement concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement with red oxide finish etc ., coplete as per direction of Engineer incharge.Sqm880.0880.0160.0FalseNoneNoneFalseNoneFalse140800.00
4086737159117None054Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed and 135 degree shoe, pipes 100 mm diameterRmtr320.1320.134.0FalseNoneNoneFalseNoneFalse10883.40
4086738159117None055Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1259.51259.552.0FalseNoneNoneFalseNoneFalse65494.00
4086739159117None056Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5No25326.425326.41.0FalseNoneNoneFalseNoneFalse25326.40
4086740159117None057Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmEach5590.25590.23.0FalseNoneNoneFalseNoneFalse16770.60
4086741159117None058LT ELECTRICAL WORKS Open Conduit System: Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thickMtr81.081.070.0FalseNoneNoneFalseNoneFalse5670.00
4086742159117None059Concealed conduit System: Supplying heavy gauge PVC conduit pipe……mm dia thick confirming to IS 2509 with suitable size bends, metal/ PVC junction boxes, adhesive paste etc., and running before concreating the slab . The conduit should be tied to the reinforcement rods by using bending wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickMtr78.078.0210.0FalseNoneNoneFalseNoneFalse16380.00
4086743159117None060Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach56.056.040.0FalseNoneNoneFalseNoneFalse2240.00
4086744159117None061Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. upto 50mm conduit CC floorMtr69.069.0120.0FalseNoneNoneFalseNoneFalse8280.00
4086745159117None062Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch boxPoint269.0269.08.0FalseNoneNoneFalseNoneFalse2152.00
4086746159117None063Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch boxPoint379.0379.010.0FalseNoneNoneFalseNoneFalse3790.00
4086747159117None064Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch boxPoint555.0555.025.0FalseNoneNoneFalseNoneFalse13875.00
4086748159117None065Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1 sqmmMtr19.019.050.0FalseNoneNoneFalseNoneFalse950.00
4086749159117None066Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1.5 sqmmMtr26.026.0510.0FalseNoneNoneFalseNoneFalse13260.00
4086750159117None067Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 2.5 sqmmMtr42.042.0460.0FalseNoneNoneFalseNoneFalse19320.00
4086751159117None068Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 4 sqmmMtr63.063.0150.0FalseNoneNoneFalseNoneFalse9450.00
4086752159117None069Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 6 sqmmMtr92.092.0210.0FalseNoneNoneFalseNoneFalse19320.00
4086753159117None070Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 WayEach138.0138.03.0FalseNoneNoneFalseNoneFalse414.00
4086754159117None071Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach159.0159.08.0FalseNoneNoneFalseNoneFalse1272.00
4086755159117None072Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayEach177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
4086756159117None073Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
4086757159117None074Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 WayEach363.0363.02.0FalseNoneNoneFalseNoneFalse726.00
4086758159117None075Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 1 to 2 ModuleEach137.0137.03.0FalseNoneNoneFalseNoneFalse411.00
4086759159117None076Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 3 ModuleEach161.0161.08.0FalseNoneNoneFalseNoneFalse1288.00
4086760159117None077Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 4 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
4086761159117None078Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 8 ModuleEach284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
4086762159117None079Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 16 ModuleEach397.0397.02.0FalseNoneNoneFalseNoneFalse794.00
4086763159117None080Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps one way SwitchEach102.0102.045.0FalseNoneNoneFalseNoneFalse4590.00
4086764159117None081Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps Three way socketEach171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
4086765159117None082Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator Two ModuleEach357.0357.09.0FalseNoneNoneFalseNoneFalse3213.00
4086766159117None083Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16 Amps one way SwitchEach180.0180.08.0FalseNoneNoneFalseNoneFalse1440.00
4086767159117None084Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps Universal SocketEach236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
4086768159117None085Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone SocketEach156.0156.01.0FalseNoneNoneFalseNoneFalse156.00
4086769159117None086Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 RJ45/I.O Outlet Cat-6Each337.0337.03.0FalseNoneNoneFalseNoneFalse1011.00
4086770159117None087Supplying and fixing of metal clad industrial plugs and sockets. 3pole+earth 440V SOCKET 32AEach827.82827.822.0FalseNoneNoneFalseNoneFalse1655.640
4086771159117None088Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SPEach415.0415.09.0FalseNoneNoneFalseNoneFalse3735.00
4086772159117None089Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
4086773159117None090Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps DPEach1060.01060.03.0FalseNoneNoneFalseNoneFalse3180.00
4086774159117None091Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 Amps TPNEach3080.03080.04.0FalseNoneNoneFalseNoneFalse12320.00
4086775159117None092Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure. 8 Way SP & N Double DoorEach1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
4086776159117None093Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure. 8 Way TP & N Double DoorEach6091.06091.01.0FalseNoneNoneFalseNoneFalse6091.00
4086777159117None094Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 6ft. Copper bonded rod with backfill compoundKit6230.06230.01.0FalseNoneNoneFalseNoneFalse6230.00
4086778159117None095Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper StripMtr570.0570.08.0FalseNoneNoneFalseNoneFalse4560.00
4086779159117None096Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and - CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.Each4390.04390.01.0FalseNoneNoneFalseNoneFalse4390.00
4086780159117None097Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.04.0FalseNoneNoneFalseNoneFalse2248.00
4086781159117None098Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm ) Regular modelEach2984.02984.09.0FalseNoneNoneFalseNoneFalse26856.00
4086782159117None099Supplying of 1440 RPM Heavy duty exhaust fan of 300mm (12") size with bracket blades complete for light duty suitable for operate 230V 50Hz, AC supply.Each1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
4086783159117None100Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.50.551935.0FalseNoneNoneFalseNoneFalse25967.50
4086784159117None101Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat …….. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mmMtr555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
4086785159117None102Supplying ……. A rated 3 phase with neutral bus bar using requred capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 Amps 4x30x6mm Aluminum Strips.Mtr2465.02465.015.0FalseNoneNoneFalseNoneFalse36975.00
4086786159117None103Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest microcontroller based, digital read out of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail / flush mounting panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
4086787159117None104Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440V AC. 50Hz 12/24V DC.Each515.0515.06.0FalseNoneNoneFalseNoneFalse3090.00
4086788159117None105Supplying, fixing and wiring 3 phase Digital Ammeter / Voltmeter.Each1425.01425.03.0FalseNoneNoneFalseNoneFalse4275.00
4086789159117None106Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE POLE 100Amps 25kA MCCBEach6086.06086.02.0FalseNoneNoneFalseNoneFalse12172.00
4086790159117None107Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125 Amps 25kAEach10341.010341.01.0FalseNoneNoneFalseNoneFalse10341.00
4086791159117None108Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250Amps 25kA MCCBEach21391.021391.01.0FalseNoneNoneFalseNoneFalse21391.00
4086792159117None109Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Mtr179.84179.8445.0FalseNoneNoneFalseNoneFalse8092.80
4086793159117None110Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Mtr178.97178.9710.0FalseNoneNoneFalseNoneFalse1789.70
4086794159117None111Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm diaMtr207.9207.940.0FalseNoneNoneFalseNoneFalse8316.00
4086795159117None112Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50mCum532.4532.428.5FalseNoneNoneFalseNoneFalse15173.40
4086796159117None113Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum176.0176.028.5FalseNoneNoneFalseNoneFalse5016.00
4086797159117None114Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmMtr20.8820.8845.0FalseNoneNoneFalseNoneFalse939.60
4086798159117None115Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo27.027.06.0FalseNoneNoneFalseNoneFalse162.00
4086799159117None116Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input : 220-240V @ 50/60 Hz & power factor Greater than 0.9 along with CE approved. 2 years warranty against any manufacturing defect working under standard lectrical condition. LED light fitting 1 x 2' - 9/10 WEach551.0551.02.0FalseNoneNoneFalseNoneFalse1102.00
4086800159117None117Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input : 220-240V @ 50/60 Hz & power factor Greater than 0.9 along with CE approved. 2 years warranty against any manufacturing defect working under standard lectrical condition. LED light fitting 1 x 4' - 20/22 WEach690.0690.017.0FalseNoneNoneFalseNoneFalse11730.00
4086801159117None118Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / GirdersEach122.0122.019.0FalseNoneNoneFalseNoneFalse2318.00
4086802159117None119Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.09.0FalseNoneNoneFalseNoneFalse1539.00
4086803159117None120Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
4086804159117None121Supplying and drawing UT-CAT 6 LAN cable.Mtr38.038.0148.0FalseNoneNoneFalseNoneFalse5624.00
4086805159117None122Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 PairMtr15.015.021.0FalseNoneNoneFalseNoneFalse315.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17273526440001NoneNoneELIGIBILITYTenders from joint ventures are not acceptableNone
17273526440001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka.None
17273526440001NoneNoneELIGIBILITYThe bidder shall ensure credit of tender processing fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date of bid submission.None
17273526440000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17273526440000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17273527560000NoneNoneELIGIBILITYThe successful tenderer has to deposit 5% of contract price as security deposit before execution of agreement in the form FDR drawn from any scheduled / Nationalized bank drawn in favour of Comptroller, UHS BagalkotNone
17273527760000NoneNoneELIGIBILITYThe tenderer is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches.None
17273527860000NoneNoneELIGIBILITYEMD payments through e-payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17273527960000NoneNoneELIGIBILITYThe intending tenderer is instructed to note that they should abide by the detailed instructions and conditions contained in the standard tender documents of applicable works manual and further orders there on. The University will not upload the KW manuals separately.None
17273528050000NoneNoneELIGIBILITYRoyalty on construction materials & GST and other taxes will be deducted as per prevailing Government orders.None
17273528150000NoneNoneELIGIBILITYGST will be paid separately. The increase if any in the GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the Authority.None
17273528280000NoneNoneELIGIBILITYThe responsibility of safe custody of mechanical / electrical equipments / materials, etc., shall be with the contractor until they are finally handed over to be department.None
17273528350000NoneNoneELIGIBILITYThe cable trench and laying shall be executed as per ISS No.1255-1967 duly taking all necessary precaution.None
17273528460000NoneNoneELIGIBILITYAll necessary drawings, paper works, etc., and any other formalities required to be observed shall be the responsibility of contractor.None
17273528590000NoneNoneELIGIBILITYWhenever executing authority insist proof of having purchased the materials (used during executing the work) for verification the contractor shall produce the purchase bills.None
17273528700000NoneNoneELIGIBILITYIt is the responsibility of contractor to observe all necessary formalities of electricity companies for charging the lines and taking over the infrastructure like breaker lines TCs by electricity companies satisfactorily duly acknowledging the inventory of materials used in the work.None
17273528780000NoneNoneELIGIBILITYThe contractor is responsible for safety and security of all materials.None
17273528860000NoneNoneELIGIBILITYThe contractor shall guarantee all the materials supplied by him including erection, electrification work for trouble free top class performance and against manufacturing defects, for a period of one year from the date of satisfactory completion and commissioning. The contractor shall make his own arrangement for rectifying defects/replacement of defective materials immediately on receipt of intimation from executing authority and power supply shall be restored. Failure of which, action will be taken to get the work rectification through other agency at the cost and risk of the contractor.None
17273528940000NoneNoneELIGIBILITYThe contractor shall not deviate/alter/execute excess quantities or additional items without the prior approval of the competent authority.None
17273529110000NoneNoneELIGIBILITYIt is the responsibility of the contractor to pursue and obtain all necessary approvals.None
17273529250000NoneNoneELIGIBILITYAfter delivery at site, the materials will be inspected, if the materials do not conform to relevant ISS/ISI and technical specifications by the University, then such materials will be rejected. The contractor shall replace the rejected materials at his own cost.None
17273529380000NoneNoneELIGIBILITYThe tenderer shall pass on to the department all the warranties, benefits etc., from the original equipment manufactures.None
17273529530000NoneNoneELIGIBILITYThe Contractor shall be solely responsible, not withstanding any stipulation by Owner or Engineer, for initiating, maintaining and supervising all safety precautions and programs, in connection with the work, and shall comply with all laws, ordinances, codes, rules, regulations and lawful orders of any public authority having jurisdiction for the safety of persons or property or to protect them from damages, injury or loss during the entire contract period, including non-working hours. Contractor shall maintain first aid facilities at site. All critical injuries shall be reported promptly to Engineer with a copy of Contractors report covering each personal injury, requiring the attention of a physician.None
17273529650000NoneNoneELIGIBILITYThe Contractor shall supervise and carry out the Works as per the approved shop drawings or part there of efficiently and with his best skill and attention. He shall be solely responsible for means, methods, techniques, procedures and sequences of construction. The Contractor shall coordinate all parts of the Works and shall be responsible to see that the finished work complies fully with the Contract Documents, and such other instructions and variation orders as the Engineer may issue during the progress of the Works.None
17273529730000NoneNoneELIGIBILITYAs per Karnataka State Government order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and G.No. PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1% of the bill amount will be deducted labour welfare fund.None
17273529860000NoneNoneELIGIBILITYConditional Tenders will not be accepted.None
17273529960000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17273530090000NoneNoneELIGIBILITYThe bidders should submit the Bid capacity of his firm. The details of 1.4(A) & 1.4(B) as applicable should be submitted in the prescribed format & should be signed by the concerned by the competent authority. In case the bidder does not furnish the above details/suppresses the actual facts/ produces false facts, along with the Technical bid, the technical bid of such bidder shall be considered for rejection.None
17273530200000NoneNoneELIGIBILITYAll the documents to be furnished are to be attested by the Gazetted officer or by Notary before uploading in the e- Procurement portal.None
17273530280000NoneNoneELIGIBILITYAll the tenderers shall get updated with corrigendum / addendum issued from time to time during the entire tender process.None
17273530400000NoneNoneELIGIBILITYContractors are advised to contact the department about the documentation and for other information before uploading the tender. Insufficient documentation will result in rejection of tender.None
17273530520000NoneNoneELIGIBILITYIn the case of the death of a contractor after executing the agreement / commencement of the work, his legal heir, if an eligible registered contractor and willing can execute and complete the work at the accepted tender rates irrespective of the cost of the work.None
17273530630000NoneNoneELIGIBILITYContractors should not sub contract the works awarded for them.None
17273530720000NoneNoneELIGIBILITYTenders with sublet / sub contract work done certificates are not acceptable.None
17273530850000NoneNoneELIGIBILITYThe bidders are informed to visit e-procurement portal for KW-2 manual and are abide to conditions laid in the manual (No separate KW-1 manual is uploaded by this office)None
17273530970000NoneNoneELIGIBILITYIt shall be the responsibility of the tenderers for the safety of the labourers deployed by them at work spot. University will not be responsible for any accidental injury I death occurred to the labourers deployed by the tenderers.None
17273531070000NoneNoneELIGIBILITYIf 2 agencies have quoted same service charge, then bidder will be selected as per their maximum average for the last three year turnover of the bidder.None
17273531200000NoneNoneELIGIBILITYThe Contractor shall quote the rates without adding GST & GST will be paid to the contractor separately over and above the contractors bid amount. The increase if any in the GST shall not be paid in the extended period of contract for which the contactor alone is responsible for delay as determined by the Authority.None
17273531300000NoneNoneELIGIBILITYThe bidder should submit the PF & ESI registration certificate at the time of agreement.None
17273536060000NoneNoneELIGIBILITYContractor should compulsorily submit the material dispatch permit (MDP) obtained from the department of mines and geology for royalty materials. If the bill is submitted without attaching the MDP, the bill will be rejected as per Department of mines and geology circular No. dated: 07/11/2023. (Circular copy attached)None
17273536200000NoneNoneELIGIBILITYThe defect liability period shall be 1 Years from the date of completion of work.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneTo qualify for Award of this contract, i Each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 A. Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Rs.84.71 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Satisfactory Performance Certificate
NoneNoneNoneNoneCertificates for having completed any one single civil work during the past 5 years satisfactorily from the date of notification. The value of such works should be minimum 50% of the amount put to tender for the works mentioned in the notification with any Govt. or Semi-Government organization with work done certificate issued by an officer not below the rank of Executive Engineer. The request received without the above said certificates shall be rejected without further notice. Attach work Done certificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneInformation on works for which tenders have been submitted and works which are yet to be completed as on the date of this tender under section 1.4 (A) of qualification information of standard bid document for existing commitments and ongoing works (Information shall be as per the relevant table). The contractor shall enclose/attach all necessary certificates duly attested by the employer. (Enclose 1.4 (A))Past Experienceexisting commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Enclose existing commitments and ongoing works
NoneNoneNoneNoneInformation on works for which tenders have been submitted and works which are yet to be completed as on the date of this tender under section 1.4 (B) of qualification information of standard bid document for works for which tenders already submitted (Information shall be as per the relevant table). (Enclose 1.4 (B))Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Enclose works for which tenders already submitted
NoneNoneNoneNoneThe list of work performed as prime contractor (In the same name) on works of similar nature during the last 5 years i.e. for 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 as per sub clause table 1.3 of section 3 of standard bid document (as per relevant table)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneIncome tax returns of proceeding three years. (2020-21, 2021-22 & 2022-23)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneDetails of total value of engineering construction works executed and payments received in the last five years (in lakhs) i.e 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24. Enclose the certificate issued by the chartered accountant with chartered accountant UDIN number. (Attach Turnover certificate)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneCurrent certificate of the Registration in KPWDOthersCurrent certificate of the Registration in KPWD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneUpload additional performance security for unbalanced tender amount in the form of DD issued from any nationalized / scheduled bank (In favour of COMPTROLLER, UHS, Bagalkot). If not uploaded the document the tenderer will be rejectedOthersadditional performance security
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- additional performance security for unbalanced tender amount in the form of DD
NoneNoneNoneNonePAN card (Enclose PAN Card)OthersPan Card
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN Card
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Current certificate of the Registration in KPWDTrueTechnical Bid
PAN card. Enclose PAN CardTrueTechnical Bid
Income tax returns of proceeding three years. 2020-21, 2021-22 & 2022-23TrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
To qualify for Award of this contract, i Each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 A. Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Rs.84.71 lakhsTrueTechnical Bid
Certificates for having completed any one single civil work during the past 5 years satisfactorily from the date of notification. The value of such works should be minimum 50 percentage of the amount put to tender for the works mentioned in the notification with any Govt./Semi-Government organization with work done certificate issued by an officer not below the rank of Executive Engineer. The request received without the above said certificates shall be rejected without further noticeTrueTechnical Bid
Upload additional performance security for unbalanced tender amount in the form of DD issued from any nationalized / scheduled bank In favour of COMPTROLLER, UHS, Bagalkot. If not uploaded the document the tenderer will be rejectedTrueTechnical Bid
Information on works for which tenders have been submitted and works which are yet to be completed as on the date of this tender under section 1.4 A of qualification information of standard bid document for existing commitments and ongoing works. Information shall be as per the relevant table. The contractor shall enclose/attach all necessary certificates duly attested by the employer. Enclose 1.4 ATrueTechnical Bid
Information on works for which tenders have been submitted and works which are yet to be completed as on the date of this tender under section 1.4 B of qualification information of standard bid document for works for which tenders already submitted Information shall be as per the relevant table. Enclose 1.4 BTrueTechnical Bid
The list of work performed as prime contractor In the same name on works of similar nature during the last 5 years i.e. for 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 as per sub clause table 1.3 of section 3 of standard bid document as per relevant tableTrueTechnical Bid
Details of total value of engineering construction works executed and payments received in the last five years in lakhs i.e 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24. Enclose the certificate issued by the chartered accountant with chartered accountant UDIN number. Attach Turnover certificate.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone